Packet
Williamson County · Williamson County · meeting of Aug 13, 2026 · Agenda packets
Open the original document More from Williamson County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
August 2026 Planning Commission Agenda
PC PACKET 8-13-2026 - 1 OF 4.PDF
PC PACKET 8-13-2026 - 2 OF 4.PDF
PC PACKET 8-13-2026 - 3 OF 4.PDF
PC PACKET 8-13-2026 - 4 OF 4.PDF
AUGUST 2026 PC MINUTES
02 AUGUST 2026 PC MINUTES.PDF
1.
Documents:
1.I.
Documents:
ORDER OF BUSINESS
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
1. Call to order
2. Roll Call
3.
Announcements
4.
Public Comments
5.
Consideration of Minutes
6.
Consideration of Consent Agenda
7.
Presentation of Agenda Items for Discussion and Action
8. Other Business
AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
Williamson County Administrative Complex
August 13, 2026 at 5:30 p.m.
PUBLIC COMMENTS:
Public comment is permitted on Agenda items – sign-in prior to the meeting is required.
MINUTES:
1. Approval of July 9, 2026 Minutes
CONSENT AGENDA:
2. Consent Agenda
BONDS:
3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro
Road.
4. King’s Chapel, Section 12 - Maintenance for Wastewater Collection System located off
Murfreesboro Road.
5. Lookaway Farms , Section 3 – Maintenance Bond for Wastewater Collection System
located off Clovercroft Road.
6. Reeds Vale, Section 1 - Maintenance Bond for Wastewater Collection System located
off Lampkins Bridge Road.
7. Starnes Creek, Section 2 - Maintenance Bond for Wastewater Collection System located
off Meeks Road.
8. Starnes Creek Wastewater System – Maintenance Bond for Wastewater Treatment and
Disposal System located off Meeks Road.
9. Terravista, Section 2 – Maintenance Bond for Wastewater Collection System located off
Long Lane.
10. The Grove, Section 14 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Cox Road.
OLD BUSINESS:
11. Terravista Roads, Drainage, and Erosion Control Bond Update
12. Preliminary Plat Review for Lofty Meadow Estates Subdivision, containing 5 lots on
32.3 acres located off Arno -College Grove Road in the 2 nd Voting District (1-2025-
310).
13. Preliminary Plat Review for Lot 1 of the Larry U. Turner Property LLE Subdivision,
containing 1 lot on 20.33 acres located off Taliaferro Road in the 5 th Voting District
(1-2026-301).
SITE PLANS:
14. Site Plan Review for Crews Runway, on 1,137.13 acres located off Boy Scout Road in
the 1st Voting District (5-2026-004).
15. Site Plan Review for Wyelea Farms – The Stables, on 53.70 acres located off Del Rio
Pike in the 9th Voting District (5-2026-005).
16. Site Plan Review for Non -Traditional Wastewater Treatment and Disposal System
Review for Brynn Subdivision, on 108.12 acres located off Haley Lane in the 5th Voting
District (5-2026-007).
17. Site Plan Review for Troubadour Golf and Field Club – Song Writer’s Cabins, on 2.5
acres located off Club View Drive in the 5 th Voting District (5-2026-006).
CONCEPT PLANS:
18. Concept Plan Review for Brynn Subdivision, containing 21 lot on 108.16 acres located
off Haley Lane in the 5th Voting District (1-2026-203).
19. Concept Plan Review for 1600 River Landing Drive, containing 2 lots on 22.76 acres
located off River Landing Drive in the 9 th Voting District (1-2026-204).
PRELIMINARY PLATS:
20. Preliminary Plat Review for The Villages at Triune West Subdivision, (Revised),
containing 98 Single-Family Lots, 214 Townhome Lots, and Ten (10) Non-Residential
Lots on 157.79 acres located off Horton Highway in the 5 th Voting District (1-2026-
309).
21. Preliminary Plat Review for The Villages at Triune East Subdivision (Revised),
containing 59 Single-Family Lots, 63 Townhome Lots, and Three (3) Non-Residential
Lots on 63.78 acres located off Horton Highway in the 5 th Voting District (1-2026-
310).
FINAL PLATS:
22. Final Plat Review for The Grove Subdivision, Section 18, containing 1 1 lots on 9.02
acres located off Arno Road in the 2nd Voting District (1-2026-414).
23. Final Plat Review for Dodd Family Revocable Living Trust Subdivision, containing 1 lot
on 32.12 acres located off Taliaferro Road in the 5 th Voting District (1-2026-415).
MINUTES OF THE
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
MEETING OF JULY 9, 2026
MEMBERS PRESENT
David Bailey
Brian Clifford
Don Crohan
Lee Kennedy
Steve Lane
Jessica Lucyshyn
Keith McCord
Sammie McCoy
Eddie Sanders
STAFF PRESENT
Michael Matteson, Community Development
Director
Aaron V. Holmes, Planning Director
Floyd Heflin, County Engineer
Michael Scott, Ass’t to County Engineer
Kristi Ransom, County Attorney
Joe James, Planning Coordinator
Lincoln Sweet, Senior Planner
Charlie Waldrop, Planning Technician
Michelle Mullins, Planning Assistant
The Williamson County Regional Planning Commission met in regular session Thursday,
July 9, 2026, at 5:30 p.m. in the Auditorium of the Williamson County Administrative
Complex. Commissioners Baldree, Hatcher, and Richter were unable to attend.
Chairman McCoy called the meeting to order and took Roll Call. A quorum was present.
Chairman McCoy asked if there were any announcements.
Mr. Holmes announced the following:
• Items 36 is on the Consent Agenda for Deferral ;
• Item 35 has been Withdrawn; and
• Request for Non -Agenda Item, Pine Creek, Section 2, Maintenance Bond for
Wastewater Collection System . Reports were provided to all Commissioners for
review.
Chairman McCoy asked for a motion to add Pine Creek, Section 2, Maintenance Bond for
Wastewater Collection System to the Agenda.
Commissioner Crohan made a motion to add Pine Creek, Section 2 to the Agenda.
The motion was seconded by Commissioner Sanders. The motion was unanimously
approved.
Chairman McCoy opened the floor to Public Comments.
PUBLIC COMMENTS:
Gerald Wigger, Counsel for the Terravista Homeowner’s Association (HOA), stated that
despite the orders of the Planning Commission, Jones Company has not fulfilled their
obligations to the association. One specific issue is the irrigation system. Per the Jones
Company’s attorney, they will not agree to pay for the repair or replacement of the
irrigation system. Mr. Wigger requested on behalf of the Terravista HOA, that any release
of bonds be denied.
Chairman McCoy closed the Public Comments.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 2 of 9
CONSIDERATION OF JUNE 11, 2026 MINUTES:
Chairman McCoy asked if there were comments or questions on the Minutes. Hearing
none, he asked for a motion.
Commissioner Clifford made a motion to approve the June 11, 2026 Minutes. The motion
was seconded by Commissioner Bailey. The motion was unanimously approved.
CONSENT AGENDA:
Chairman McCoy asked if there were any Items that needed to be discussed separately
on the Consent Agenda.
Hearing none, he asked for a motion to accept the Consent Agenda as a whole.
Commissioner C rohan made a motion to approve the Consent Agenda per Staff
recommendations. Commissioner Lane seconded the motion. The motion was
unanimously approved.
BONDS:
3. Arrington Ridge, Section 2 – Performance Bond for Roads, Drainage and Erosion
Control located off Cox Road. - $383,000
Recommendation: Extend in the current amount for a period of one (1) year.
4. Brightstone Campus – Performance Bond for Landscaping located off Columbia
Avenue. - $145,750
Recommendation: Extend in the current amount for a period of one (1) year.
5. Brightstone Campus - Performance Bond for Wastewater Treatment and Disposal
System located off Columbia Avenue. - $214,300
Recommendation: Extend in the current amount for a period of one (1) year.
6. Enclave at Dove Lake, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Nolensville Road. - $357,000
Recommendation: Extend in the current amount for a period of one (1) year.
7. Hardeman Springs, Section 3 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Murfreesboro Road. - $150,000
Recommendation: Extend in the current amount for a period of six (6) months, or
when Engineering staff has determined the improvements have been completed and
the bond is ready for review by the Planning Commission, whichever comes first.
8. McDaniel Estates, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off McDaniel Road. - $450,000
Recommendation: Release the bond.
9. McDaniel Estates, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off McDaniel Road. - $330,000
Recommendation: Release the bond.
10. McDaniel Estates, Section 3 - Maintenance Bond for Roads, Drainage and Erosion
Control located off McDaniel Road. - $200,000
Recommendation: Release the bond.
11. McDaniel Estates, Section 4 – Maintenance Bond for Roads, Drainage and Erosion
Control located off McDaniel Road. - $260,000
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 3 of 9
Recommendation: Release the bond.
12. McDaniel Farms, Section 1 - Maintenance Bond for Roads, Drainage and Erosion
Control located off McDaniel Road. - $430,000
Recommendation: Release the bond.
13. Reeds Vale, Section 3 – Maintenance Bond for Water (Milcrofton) located off Lampkins
Bridge Road. - $126,031.05
Recommendation: Release the bond.
14. Reeds Vale, Section 3 – Performance Bond for Roads, Drainage and Erosion Control
located off Lampkins Bridge Road. - $1,350,000
Recommendation: Reduce to the amount of $1,012,000 and extend for a period of
one (1) year.
15. Stephens Valley, Section 1 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Sneed Road. - $500,000
Recommendation: Release the bond.
16. Stephens Valley, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Sneed. - $150,000
Recommendation: Release the bond.
17. The Grove, Section 13 – Maintenance Bond or Roads, Drainage and Erosion Control
located off Arno Road. - $300,000
Recommendation: Release the bond.
18. Troubadour Golf and Club Farmstand – Performance Bond for Landscaping located off
Cox Road. - $166,674
Recommendation: Reduce to the amount of $125,006 and extend for a period of one
(1) year.
19. Troubadour, Section 8 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Cox Road. - $314,000
Recommendation: Extend in the current amount for a period of one (1) year.
20. Troubadour, Section 8 – Performance Bond for Wastewater Collection System located
off Cox Road. - $87,250
Recommendation: Extend in the current amount for a period of one (1) year.
21. Troubadour, Section 10 – Performance Bond for Wastewater Collection System
located off Cox Road. - $138,800
Recommendation: Extend in the current amount for a period of one (1) year.
22. Troubadour, Section 10 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Cox Road. - $422,000
Recommendation: Extend in the current amount for a period of one (1) year.
23. Troubadour, Section 12B – Performance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $133,000
Recommendation: Extend in the current amount for a period of one (1) year.
24. Troubadour, Section 12B – Performance Bond for Wastewater Collection System
located off Arno Road. - $16,000
Recommendation: Extend in the current amount for a per iod of one (1) year.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 4 of 9
25. Troubadour, Section 13A – Performance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $1,500,000
Recommendation: Reduce to the amount of $1,150,000 and extend for a period of
one (1) year.
26. Troubadour, Section 13B - Performance Bond for Wastewater Collection System
located off Patton Road. - $329,000
Recommendation: Extend in the current amount for a period of one (1) year.
27. Troubadour, Section 13B – Performance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $1,700,000
Recommendation: Reduce to the amount of $1,144,000 and extend for a period of
one (1) year.
28. Troubadour, Section 14 – Performance Bond for Roads, Drainage and Erosion Control
located off Patton Road. - $9,000
Recommendation: Extend in the current amount for a period of one (1) year.
29. Troubadour, Section 14 – Performance Bond for Wastewater Collection System
located off Patton Road. - $8,000
Recommendation: Extend in the current amount for a period of one (1) year.
30. Troubadour, Section 15 – Maintenance Bond for Roads, Drainage and Erosion Control
located off Cox Road. - $265,000
Recommendation: Extend in the current amount for a period of one (1) year.
31. Troubadour, Section 15 – Performance Bond for Wastewater Collection System
located off Cox Road. - $60,600
Recommendation: Extend in the current amount for a period of one (1) year.
32. Vineyard Valley, Section 2 – Maintenance Bond for Roads, Drainage and Erosion
Control located off Eudailey-Covington Road. - $154,000
Recommendation: Extend in the current amount for a period of one (1) year, or when
Engineering staff has determined the improvements have been completed and the
bond is ready for review by the Planning Commission, whichever comes first.
DEFERRAL ITEMS:
ITEM 36
PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO- COLLEGE GROVE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
At this time, the applicant is requesting deferral to the August 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 5 of 9
OLD BUSINESS:
ITEM 23
ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVIST A
SUBDIVISION, SECTIONS 1 AND 2.
Brent Thoeny, with TruLand Consultants, represented the applicant, The Jones Company.
He reported that in Phase Two (2), most everything has been completed except for a
headwall that needs to be touched up due to some erosion. The wastewater road was
touched up and recompacted . Binders should be going down the next day and the top
coat will be done the first part of next week. The pond has been completed and a flume
has been put in. However, with the rain we’ve had, it’s been hard to tell if it is draining
perfectly or not, but they will reassess it when they can. Other than these items, all other
physical items in Phase 2 have been completed. In Phase One (1), all of the pond work
has been regraded. The only outstanding items are the swale on Long Lane, which is
approximately seventy percent (70%) complete, and should be completed in the next
few days. T-Square is working on the Site Plan for the mailbox kiosk, but all other physical
work for Phase 1 has been completed.
Chairman McCoy asked what he meant by the mailbox kiosk.
Mr. Theony advised that they could not find a copy of where the mailbox kiosk Site Plan
had been originally approved, so they were having it located again.
Chairman McCoy asked if there were any other questions. Hearing none, he opened the
floor to Mr. Scott for his presentation.
Mr. Scott reviewed the current open issues for Sections 1 and in a PowerPoint
presentation. Some of the open issues were confirmation of the street inlet, storm water
pipes, etc., and he expected confirmation from the Engineer once completed. The Site
Plan for the mail kiosk was requested in February, which was what Mr. Theony previously
referred to. Mr. Scott showed photos of multiple items in Section 1 , including pond 2A,
which has had some work done and is looking better . However, it is still on the list,
because there is a gabion basket that is shown on the plans and there is some ponding,
so he wants to make sure grass takes and it is stable. The water quality swale is still
being worked on, as well as pond 1, which has been re- graded. There is still some
ponding, and it is unknown if it will require a French drain, but the grass should be grown
in and it will need to be maintained. Pond 2B is similar, and also calls for a level spreader
or gabion. There is an inlet that has some strong grades around it, which is why it is still
on the list. There are still thirteen ( 13) open issues, but most have been completed or
are in the process.
In Section 2, the wastewater access road should be completed within the next week.
Detention pond 5 had some ponding, but it does have a flume, so it may be that some
of the straw has gotten into the flume and caused some clogging. As the grass grows
and the straw is no longer there, it will be better. There are also some flumes that hav e
been put in that look good. There is still a sinkhole issue that he is waiting for Geotech
to address. He reviewed the slopes that were on the approved grading plans . Section 1
looks good, but Section 2 shows some steeper slopes, so he has asked for re -grading to
areas that are steeper than two to one (2:1). This would be a significant undertaking and
could cause more issues than it could solve, but there have been landslides there in the
past, so he wants to make sure everything is taken care of. Mr. Scott spoke to Tim Turner
with T-Square about this and Mr. Turner felt like it would be better if a Geotech reviewed
the issue to determine if the slopes need to be re-graded or if they are stable.
Commissioner Lucyshyn asked if the documentation showing where Mr. Scott asked about
a Geotech report in February 2025 is still the report that he is waiting on currently.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 6 of 9
Mr. Scott advised that there were two (2) depressions or sinkholes that looked like they
had throats and he believes a Geotech had gone out there and did mat over those areas,
but when Mr. Scott went back out during a recent visit, the throat had opened back up.
Therefore, he feels this is an ongoing issue and he feels there is not a sol ution yet for
these.
Mr. Theony stated that the first Geotech report referenced those holes and were defined
as dropout, not actually a sinkhole. They have since gone back and fixed those again and
Mr. Scott may want to take a look at them again.
Commissioner Lucyshyn advised that, per Mr. Scott’s report, there is a note dated May
13, which advises that the sinkhole may still be active.
Mr. Scott confirmed that was correct.
Commissioner Lucyshyn asked if there was an answer for that note.
Mr. Theony stated that it is the same area and incident that happened , and he believes
the Geotech advised that there was no guarantee that it wouldn’t happen again. He will
talk to the Geotech about going back out there.
Commissioner Crohan asked for more information about what Mr. Wigger had mentioned
earlier regarding the irrigation system.
Mr. Theony advised that he didn’t know much, but he was copied on an email that day
where the HOA attorney had stated that the HOA determined the irrigation pump in the
subdivision had to be replaced and they demanded that Jones Company pay for this. Per
his knowledge, Jones Company has already replaced it once before approximately two
(2) years ago.
Commissioner Crohan asked if it had been replaced recently.
Mr. Theony stated it was approximately two (2) years ago.
Commissioner Crohan asked if he was aware of anything currently wrong with it.
Mr. Theony responded that from the email he received it appeared to have already been
replaced and were asking Jones Company to pay for it.
County Attorney, Kristi Ransom, advised that the County does not bond irrigation systems
and it is not part of the Roads, Drainage and Erosion Control bond.
Commissioner Crohan asked when this project was going to be completed and that he
doesn’t want to see it going into winter.
Mr. Theony stated that he intended for it to be completed within the next five (5) to ten
(10) days.
Commissioner Bailey advised that it is hard for the Planning Commission to see based on
narrative updates what is actually taking place as far as the work that is being done. He
feels that it is great that everything should be completed by the next Planning Commission
meeting, but if it were not, he would like to see a chart that plainly shows what items are
left and when they are scheduled to be executed.
Mr. Theony agreed to that.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 7 of 9
PRELIMINARY PLATS:
ITEM 34
PRELIMINARY PLAT REVIEW FOR WILD OAK LLE SUBDIVISION, CONTAINING
5 LOTS ON 35.60 ACRE S LOCATED OFF COLEMA N ROAD IN THE 9 TH VOTING
DISTRICT (1-2026-308).
Mr. Sweet reviewed the background (see Staff Report) recommending approval of this
Preliminary Plat with the following conditions:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit;
2. Fire hydrants shall be installed within 500 feet of all building envelopes. A report
from H.B. & T.S. Utility District shall be submitted prior to Final Plat approval
certifying the flow rates of all hydrants meet the required minimum rate of 500
gpm;
3. Establishment of a Performance Bond for water improvements in favor of H.B. &
T.S. Utility District;
4. A Land Disturbance Permit must be obtained for the overall development; and
5. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with Zoning Ordinance requirements. The applicant shall
notify Engineering Department Staff in order to conduct the required inspection.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner Clifford made a motion to approve per Staff recommendation.
Commissioner Bailey seconded the motion. The motion was unanimously approved.
ITEM 35
FINAL PLAT REVIEW FO R FOSTER SUBDIVISION FAMILY SUBDIVISION,
CONTAINING 1 LOT ON 1.40 ACRES LOCATED O FF TALIAFERRO ROAD I N THE
5TH VOTING DISTRICT (1-2026-409).
This Item has been Withdrawn.
This Item is on the Consent Agenda for Deferral.
ITEM 36
PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GROVE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 8 of 9
FINAL PLATS:
ITEM 37
FINAL PLAT REVIEW FO R MARLOWE SPRINGS AT CARL ROAD SUBDIVISI ON,
CONTAINING 5 LOTS ON 91.81 ACRES LOCATED OFF CARL ROAD IN TH E 9TH
VOTING DISTRICT (1-2026-413).
Mr. Sweet reviewed the background (see Staff Report) recommending approval of this
Preliminary Plat with the following conditions:
1. The applicant shall adopt and record a covenant that declares that the access
easement is not a public road, and imposes the requirem ent of maintenance by
all properties served by the access easement. The covenant shall be recorded
concurrently with the recording of the plat; and
2. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
apparatus access requirements for all lots, prior to building permit issuance.
Chairman McCoy asked if there were any questions.
Commissioner Crohan asked if the stub road was going to be for future development.
Mr. Sweet clarified that this was just a continuation of the subdivision road on the plans
and not a road stubbed to an adjacent property.
Commissioner Crohan made a motion to approve per Staff recommendation.
Commissioner Clifford seconded the motion. The motion was unanimously approved.
ITEM 38
FINAL PLAT (REVISED) REVIEW, FLINT MEADO WS SUBDIVISION,
CONTAINING 3 LOTS ON 18.25 ACRES LOCATED OFF STEEPLECHASE LA NE IN
THE 8TH VOTING DISTRICT (1-2026-400).
Mr. Waldrop reviewed the background (see Staff Report) recommending approval of this
Final Plat with the following conditions:
1. Fire hydrants shall be installed within 500 feet of all building envelopes. A report
from Harpeth Valley Utility District shall be submitte d prior to Final Plat approval
certifying the flow rates of all hydrants meet the required minimum rate of 500
gpm; and
2. The applicant shall submit a signed and notarized ‘Family Subdivision Affidavit
and Restrictive Covenant,’ which shall be recorded concurrently with the recording
of the plat. After the ‘Family Subdivision Affidavit and Restrictive Covenant’ has
been recorded and prior to application for building permits, t he applicant shall
provide a copy to the Planning Department.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner Crohan made a motion to approve per Staff recommendation.
Commissioner Bailey seconded the motion. The motion was unanimously approved.
Williamson County Planning Commission
Meeting of Jul 9, 2026
Page 9 of 9
NON-AGENDA ITEM
PINE CREEK, SECTION 2 - MAINTENANCE BOND FOR WASTEWATER
COLLECTION SYSTEM
Mr. Holmes advised that the Bond has satisfied the requisite two (2) year maintenance
period, and Staff recommended to release the Bond.
Chairman McCoy asked if there were any other questions. Hearing none, he asked for a
motion.
Commissioner Crohan made a motion to approve per Staff recommendation.
Commissioner Lane seconded the motion. The motion was unanimously approved.
Chairman McCoy asked for a motion to adjourn.
Commissioner Clifford made a motion to adjourn. There being no further business, the
meeting was adjourned at approximately 5:57 p.m.
APPROVED BY A MAJORITY VOTE BY THE WILLIAMSON COUNTY REGIONAL
PLANNING COMMISSION ON AUGUST 13, 2026
____________________________________
Chairman
CONSENT AGENDA
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
WILLIAMSON COUNTY ADMINISTRATIVE COMPLEX
AUGUST 13, 2026
BONDS:
3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro
Road. - $67,950
Recommendation: Extend in the current amount for a period of six (6) months.
4. King’s Chapel, Section 12 - Maintenance Bond for Wastewater Collection System
located off Murfreesboro Road. - $21,000
Recommendation: Release the bond.
5. Lookaway Farms, Section 3 – Maintenance Bond for Wastewater Collection System
located off Clovercroft Road. - $15,000
Recommendation: Release the bond.
6. Starnes Creek , Section 2 –Maintenance Bond for Wastewater Collection System
located off Meeks Road. - $12,900
Recommendation: Release the bond.
7. Starnes Creek Wastewater Area – Maintenance Bond for Wastewater Treatment and
Disposal System located off Meeks Road. - $120,700
Recommendation: Release the bond.
8. Terravista, Section 2 - Maintenance Bond for Wastewater Collection System located
off Long Lane. - $48,300
Recommendation: Release the bond.
9. Reeds Vale, Section 1 – Maintenance Bond for Wastewater Collection System located
off Lampkins Bridge Road. - $96,600
Recommendation: Release the bond.
10. The Grove, Section 14 – Maintenance Bond or Roads, Drainage and Erosion Control
located off Arno Road. - $425,000
Recommendation: Release the bond.
DEFERRAL ITEMS:
ITEM 12
PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO-COLLEGE GROVE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
ITEM 16
SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND
DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRES
LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
ITEM 17
SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG
WRITER’S CABINS, ON 2.5 ACRES LOCATED OFF CLUB VIEW DRIVE IN THE
5TH VOTING DISTRICT (5-2026-006).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
ITEM 18
CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON
108.16 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (1 -
2026-203).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
ITEM 19
CONCEPT PLAN REVIEW FOR 1600 RIVER LANDING D RIVE SUBDIVISION,
CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING DRIVE
IN THE 9TH VOTING DISTRICT (1-2026-204).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
FINAL PLATS:
ITEM 22
FINAL PLAT REVIEW FOR THE GROVE SUBDIVISION, SECTION 18,
CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND
VOTING DISTRICT (1-2026-414).
Final Plat is in order, and Staff recommends approval with the following conditions:
1. Establishment of a maintenance bond for water improvements in favor of
Milcrofton Utility District in the amount of $44,332.30;
2. Per the recommendation of the County’s Wastewater Consultant, establishment of
a performance bond for the wastewater collection system in the amount of
$137,924.71;
3. Execution of performance agreements for the above reference d sureties;
4. The approved HOA documents must be recorded concurrently with the recording
of the Final Plat;
5. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
6. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
MOTION TO ACCEPT STAFF RECOMMENDATION
1
st _____ 2nd ______ VOTE: ___________
NOTE: All matters listed under the consent agenda are considered to be routine.
There will be no separate discussion of these items unless a Planning
Commission member so requests, in which case it will be removed from the
Consent Agenda so that discussion may be held on that item.
Reviewer: OCW
Date: 08/13/2026
ITEM 3
NAME: 1200 OLD HILLSBORO ROAD
BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING
LOCATION: OLD HILLSBORO RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
April 2022 Performance
Landscaping Implemented $90,600
February 2024 Performance
Landscaping Extend $90,600
February 2025 Performance
Landscaping Extend $90,600
February 2026 Performance
Landscaping
Reduce to
Maintenance &
Extend
$67,950
LAST ACTION: At the February 2026 meeting, this body granted approval reduced to
Maintenance in the amount of $67,950 for a period of six (6) months.
RECOMMENDATION: Staff visited the site and noted the landscaping ha d been
installed. Staff recommends extending the bond for six (6) mont hs to allow completion
of the Maintenance Period.
CURRENT RECOMMENDED
$67,950 $67,950
Maintenance Maintenance
Reviewer: AVH
Date: 08/13/2026
ITEM 4
NAME: KING’S CHAPEL, SECTION 12
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF MURFREESBORO RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
July 2022 Performance WW
Collection System Implemented $70,000
August 2023 Performance WW
Collection System Extend $70,000
August 2024 Performance WW
Collection System
Reduce to
Maintenance and
Extend
$21,000
LAST ACTION: At the August 2024 meeting, this body granted approval for this bond
to be reduced to maintenance in the amount $21,000 for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond .
CURRENT RECOMMENDED
$21,000
Maintenance Release
Reviewer: AVH
Date: 08/13/2026
ITEM 5
NAME: LOOKAWAY FARMS, SECTION 3
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF CLOVERCROFT RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION TAKEN BOND
AMOUNT
August 2022 Performance WW
Collection System Implemented $50,000
August 2023 Performance WW
Collection System Extend $50,000
August 2024 Performance WW
Collection System
Reduce to
Maintenance and
Extend
$15,000
LAST ACTION: At the August 2024 meeting, this body granted approval that this bond
be reduced to maintenance in the amount of $15,0 00 for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the b ond.
CURRENT RECOMMENDED
$15,000
Maintenance Release
Reviewer: AVH
Date: 08/13/2026
ITEM 6
NAME: REEDS VALE, SECTION 1
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF LAMPKINS BRIDGE ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
May 2023 Performance WW
Collection System Implemented $322,000
May 2024 Performance WW
Collection System Extend $322,000
August 2024 Performance WW
Collection System
Reduce to
Maintenance and
Extend
$96,600
LAST ACTION: At the May 2024 meeting, this body granted approval that this bond be
reduced to maintenance in the amount of $96,6 00 for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$96,600
Maintenance Release
REVIEWER: AVH
DATE: 08/13/2026
ITEM 7
NAME: STARNES CREEK, SECTION 2
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF MEEKS RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING
DATE
BOND TYPE ACTION
TAKEN
BOND AMOUNT
July 2023 Performance WW
Collection System Implemented $43,000
July 2024 Performance WW
Collection System
Reduce to
Maintenance and
Extend
$12,900
LAST ACTION: At the July 2024 meeting, this body granted approval that this bond be
reduced to maintenance in the amount of $12,900 for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$12,900
Maintenance Release
REVIEWER: AVH
DATE: 08/13/2026
ITEM 8
NAME: STARNES CREEK WASTEWATER AREA
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER TREATMENT AND
DISPOSAL SYSTEM
LOCATION: OFF MEEKS RD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION
TAKEN
BOND AMOUNT
January 2019
Performance WW
Treatment and
Disposal
Implemented $120,700
August 2023
Performance WW
Treatment and
Disposal
Extend $120,700
August 2024
Performance WW
Treatment and
Disposal
Reduce to
Maintenance and
Extend
$120,700
LAST ACTION: At the August 2024 meeting, this body granted approval that this bond
be converted to maintenance in the current amount for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$120,700
Maintenance Release
REVIEWER: AVH
DATE: 8/13/2026
ITEM 9
NAME: TERRAVISTA, SECTION 2
BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION
SYSTEM
LOCATION: OFF LONG LANE
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION
TAKEN
BOND AMOUNT
September 2022 Performance WW
Collection System Implemented $161,000
August 2023 Performance WW
Collection System Extend $161,000
August 2024 Maintenance WW
Collection System
Reduce to
Maintenance and
Extend
$48,300
LAST ACTION: At the August 2024 meeting, this body granted approval that this bond
be reduced to maintenance in the amount of $48,300 for a period of two (2) years.
RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommends releasing the bond.
CURRENT RECOMMENDED
$48,300
Maintenance Release
Reviewer: MS
Date: 08/13/2026
ITEM 10
NAME: THE GROVE, SECTION 14
BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND
EROSION CONTROL
LOCATION: OFF ARNO ROAD
BACKGROUND: The following table shows the previous history of the bond.
MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT
November 2020 Performance RDE Implemented $850,000
December 2021 Performance RDE Reduce to Maint &
Extend
$623,000
December 2022 Maintenance RDE Extend $623,000
December 2023 Maintenance RDE Extend $623,000
December 2024 Maintenance RDE Extend $623,000
December 2025 Maintenance RDE Reduce & Extend $425,000
LAST ACTION: At the December 2025 meeting, this body granted approval to reduce
the Maintenance Bond to $425,000 and extend for a period of one (1) year.
RECOMMENDATION: Staff visited the site an d noted that all improvements are
complete. The roadways are private and will be maintained by the HOA. Staff
recommends that the Maintenance Bond be released.
CURRENT RECOMMENDED
$425,000
Maintenance Release
Item 11—Page 1 of 1
Reviewer: MS
Date: 8/13/2026
ITEM 11
TERRAVISTA ROADS, DRAINAGE, AND EROSION CONTROL BOND UPDATE
Item 12—Page 1 of 1
Reviewer: LS
Date: 8/13/2026
ITEM 12
PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GROVE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
Area 32.3 acres
Lots 5
Zoning Rural Development-5 (RD-5)
Water Milcrofton Utility District
Sewer Individual On-Site Septic Systems
Development Options Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 142---02901
File Number (1-2025-310)
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Item 13—Page 1 of 2
Reviewer: LS
Date: 8/13/2026
ITEM 13
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION , CONTAINING 1 LOT ON 20.33 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-301).
Attachment 13-1 Preliminary Plat
13-2 Aerial Photograph
13-3 Request for Variance
13-4 Applicant’s Petition for Variance
Area 20.33 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Individual Well
Sewer Individual On-Site Septic System
Development Option Large Lot Easement
Chapter 1101 Status Rural
Map and Parcel 159---01104
File Number (1-2026-301)
The subject parcel is approximately twenty (20) acres in size and is located off Taliaferro
Road, approximately 1/3 of a mile nort h of John Windrow Road . The applicant is
requesting approval of a Large Lot Easement Subdivision in order to create the second
(2
nd) lot off an existing fifty-foot (50’) ingress/egress/utilities easement known as Bo
Lane.
All Zoning Ordi nance requirements, including those regarding the protection of natural
resources, have been met.
The applicant is proposing individual septic systems for the lot, and the Williamson County
Department of Sewage Disposal Management has approved the request. Water will be
provided by an individual private well . As no fire hydrants are proposed, fire sprinkler
systems shall be installed in all habitable structures on Lot 1, as outlined in Section
3.05(B)(2)(b)(i) of the Subdivision Regulations . This has been made a condition of
approval.
The property in question will take access from Bo Lane, an existing fifty-foot (50’)
easement that has been in existence since 2001 and extends from Taliaferro Road and
serves the applicant’s lot and one (1) other lot , which is located at the end of Bo Lane
and within Rutherford County . The existing driveway varies betwe en twelve (12) and
sixteen (16) feet in width for the entire length of Bo Lane. As the existing, varying-width
driveway does not meet the required 16 -foot driveway width per Section 3.02(D)(2) of
Item 13—Page 2 of 2
Reviewer: LS
Date: 8/13/2026
the Subdivision Regulations, the applicant is requesting a Variance from Section
3.02(D)(2) of the Subdivision Regulations so as not to be required to widen the easement
to sixteen (16) feet where it currently is not sixteen (16) feet in width (See Attachments
13-3 and 13-4).
Because the easement has been in exis tence since 2001 , and because the applicant is
willing to sprinkle all habitable structures, Staff is not opposed to the Variance.
The Preliminary Plat is in order , and so long as the Planning Commission grants the
Variance, Staff recommends approval, subject to the following conditions, which must be
addressed in conjunction with Final Plat submittal:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit, if there is 1-acre or more of disturbance;
2. Prior to submittal of the Final Plat, provide a letter from the water provider either
stating the water lines are installed and functioning or listing a Performance Bond
amount for water improvements;
3. A Land Disturbance Permit must be obtained for the overal l development;
4. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with County regulations;
5. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire
sprinkler system requirements; and
6. Affixing a note to the Plat noting that all structures, including accessory structures,
shall be separated by a minimum of 200 feet .
ROAD
TALIAFE
FERRO
ROAL
PIN2 IRON
93241
876
EXISTING
DIDIR
N
000240
W
993.:21
M.B.S
THOMAS R. BENNING
AFERRO ROAD
5R.O.W.C
RON
IRON
LOT
821 PAGE 514 ROWC
20.03 ACRES
872,715 SQ.FT.
FORPRINCIPAL
WILLIAMDY
oUNTY
LOCATI
CATION
PER
DEED;
APPROX.)
RUTHERFORD
COUNTY
(APPROX.
LOCATION
FOUND
PIN
AREA MАР
SCALE 1":100'
LANE
STUMP HOLE MAY BE
PLAT BOOK J PACE IEB R
(APP
28.92 A
OT A PART OF THIS SUBDIVISION)
MARIA A FENA
RECTURD BOIK S PAGIE
LEGEND
ND ELECTH
ASPHALT SURP
SCALE:
STATS
PLANE
STATE
PLANE
NORTH
CHAPDELAINE
& ASSOCIATES
LAND SURVEYING
FAIR
AFERRO
BO LANE
SITE
N.T.S.
SITE
MAP
2
TEMEN
ISNOT A GENERAL
RULE 0820-03-07
ATE BOARD OF
PRELIMINARY
PLAT
ED LAND O
NNESSEE NO
4 Ana 2026
RELIMINARY
RT PAUL RUSSELL
COLE DANIELLE RUSSELL
E- EAGLEVILLE, TN
DEED BOOK 9821 PAGE 514 R.O.w.c.
BOOK P44 PAGE 104 R.O.W.C.
TY MAP 159 PARCEL 11.
LOTI
2.122.5a5 TOTAL S
V-0.0
LAH
RGE
LOT
OFF
AN
EASEMENT
SUBDIVISIO
ION
LOT
1 OF
THE
T
LARRY
U.
TURNER
PROPERTY
SUBDI
ОIVISION
ATE
ATTACHMENT 13-1
Property: Tax Map 159, Parcel 01104 (approximately 49 acres, accessed via Bo Lane)
Dear Members of the Planning Commission:
FACTS
41468101vl
DOUGLAS BERRY
Direct Dial 615-744-8620
Direct Fax 615-744-8635
doug.berry@millermartin com
Williamson County Regional Planning Commission
c/o Williamson County Planning Department
1320 West Main Street, Suite 400
Franklin, Tennessee 37064
This letter addresses a single issue, relief from the 16-foot shared driveway width requirement of
the Sub Regs. The Applicants’ legal positions taken in the case pending before the Board of Zoning
Appeals, and all other legal rights and remedies, are expressly reserved. The grant of the variance requested
here would resolve this matter, however, and obviate the need for further proceedings.
Bo Lane was created on April 26, 2001, with the recording of the survey of the Larry U. Turner
property, as a non-exclusive, fifty-foot-wide ingress-egress and utility easement (Plat Book 31, Page 103)
(Exhibit 1, attached) (Hereinafter “the Turner Survey”). Bo Lane extends westerly to Taliaferro Road, a
public road.
Shortly after the recording of the Turner Survey, in separate transactions, the Turners sold Tracts 5
and 9 to one buyer and Tract 8 to another buyer. These tracts have enjoyed continuous right of access to
Taliaferro Road via Bo Lane. Tracts 8 and 9 lie in large part within Rutherford County and are to the east
of the Property, that is, further away from Taliaferro Road. The deeds to these tracts are attached as Exhibits
2 and 3. Both deeds contain reciprocal obligations for maintenance of the access easement.
401 Commerce Street
Suite 720
Nashville, TN 37219-2449
615-244-9270
Fax 615-256-8197
MILLERMARTIN
Re: Petition for Variance from 16-Foot Shared Driveway Width Requirement, Section
3.02(D)(2)(a) of the Williamson County Subdivision Regulations
This firm represents Robert and Nicole Russell (“Applicants”), the owners of an approximately 49-
acre parcel accessed by Bo Lane (“the Property”), which is a recorded 50-foot ingress/egress and utility
easement. Pursuant to Section 1.09(A) of the Williamson County Subdivision Regulations (the “Sub
Regs”), the Applicants respectfully request a variance from the requirement in Section 3.02(D)(2)(a) that
lots in a Large Lot Easement (“LLE”) Subdivision must take access from a shared driveway with a
minimum width of 16 feet.
ATTACHMENT 13-4
APPLICABLE STANDARD
Section 1.09(A) of the Sub Regs provides:
DISCUSSION
41468101vl
In other words, the Sub Regs already recognize that sprinklers combined with 200-foot building
envelope separation are a substitute for the apparatus access standards, including the 16-foot width
component.
1. The Sub Regs Provide and the Applicants Have Committed to an Alternative Standard That
Serves the Same Purpose as the 16-Foot Width Requirement.
Williamson County Regional Planning Commission
Page 2
The Property is composed of Tract 7 and a portion of Tract 4 as shown on the Turner Survey. Tract
4 has had access to Bo Lane continuously since the easement’s creation. Tract 7 does not appear to have
ever had access to Bo Lane. The Property itself was created by deed in 2022 by three parties unrelated to
the Applicants. The Applicants purchased the Property in 2025 to construct a single-family home. See
Exhibit 4. No new roads or utilities are proposed.
The Property satisfies the requirements applicable to an LLE Subdivision under the Sub Regs with
a single exception: the 16-foot minimum shared driveway width specified in Section 3.02(D)(2)(a). With
respect to fire protection, the applicants have agreed to install automatic sprinkler systems in all habitable
structures on the Property and to space building envelopes no closer than 200 feet apart - a combination
that, as explained below, the Sub Regs expressly treat as a substitute for the fire apparatus access standards,
including the 16-foot shared driveway width contained within those standards.
“Whenever a parcel of land to be subdivided contains extraordinary, exceptional or unique
situations, or is surrounded by such development of unusual conditions that the strict application
of the requirements contained in these Regulations would result in substantial hardship or inequity,
the Planning Commission may vary or modify, except as otherwise indicated, such requirements
of design, but not of procedure or improvements, so that the subdivider may develop the property
in a reasonable manner, keeping in mind that the public welfare and interests of the County are
protected and the general intent and spirit of these Regulations are preserved. Such modifications
may be granted by the Planning Commission upon written request by the subdivider, stating the
reason(s) for each modification.”
The purpose of the 16-foot shared driveway width is to ensure adequate fire apparatus access. The fire
protection standards of Section 3.05(B)(2) confirm as much: under Section 3.05(B)(2)(b), where fire
hydrants are not provided, building envelopes must be spaced no closer than 200 feet apart, and the
applicant must then provide either (i) sprinkler systems in all habitable structures, or (ii) the full fire
apparatus access package - which includes maximum driveway grades, turnaround requirements, an
apparatus staging area, and the same 16-foot minimum shared driveway width.
41468101vl
Widening Bo Lane to 16 feet would require reconstructing approximately 3,200 linear feet of travel
way, and is not practically feasible without materially disturbing existing infrastructure, neighboring
operations, and natural features, including:
The Applicants sought the Fire Service’s review of Bo Lane early and accept its conclusion that the
road, in its present condition, does not meet the apparatus-access standard. That conclusion is why the
Applicants have committed to the alternative the Sub Regs themselves provide: sprinkler systems in every
habitable structure, which act on a fire before apparatus arrives at all. Section 3.05(B)(2)(b) does not require
both.
3. Widening Bo Lane Is Physically Impossible Without Substantial Impact to Third Parties
and Approvals from Agencies Outside the County’s Control.
The Applicants have committed to sprinkler systems in all habitable structures and a minimum 200-
foot separation between building envelopes. The safety objective underlying the 16-foot width requirement
is therefore fully served here through the alternative path the drafters of the Sub Regs themselves provided.
2. The Applicants Cannot Widen Bo Lane Without Displacing Rights Held by Others and
Requiring Them to Bear That Burden Alone Would Be Inequitable.
Page 3
Thus, granting the requested variance does not ask the Commission to waive a safety protection; it asks
the Commission to recognize that the Sub Regs’ own alternative protection is being provided.
The Williamson Fire/Rescue Coordinator, in his April 15, 2026, letter (Exhibit 6) made this very
observation, suggesting that it would be equitable for neighbors or county government to share in the cost
of any required improvements rather than placing the entire financial burden on a single property owner.
That is precisely the “substantial hardship or inequity” that Section 1.09(A) empowers this Commission to
relieve.
Bo Lane is a non-exclusive easement. The Applicants share it with other owners holding co-equal
rights of use. The easement also carries recorded utility interests serving neighboring households. The
Applicants do not have the right to widen Bo Lane without disturbing improvements that are not theirs to
disturb. They have no legal authority to relocate recorded interests held by others. Private water lines
serving three neighboring households run within the corridor along its southern edge - themselves an
authorized use of an easement granted for utilities as well as access, and expressly excepted in the recorded
conveyances. One neighboring landowner’s fencing for an active livestock operation borders the northern
edge. Any widening reaches one or both. The Applicants have no right to displace their neighbors’ water
service and no means of compelling the cooperation that widening would require.
On the other hand, requiring the Applicants alone to bear the burden and expense of physically
expanding a shared easement that benefits multiple existing homes would impose the entire cost of a shared
benefit on a single property owner. The scope of that work is substantial: reconstruction of approximately
3,200 linear feet of travel-way, excavation of new drainage ways, installation of new culvert pipes,
relocation of the water lines serving three neighboring households, and relocation of a neighboring
landowner’s fencing - estimated at $150,000, per the enclosed estimate. (Exhibit 5).
• Ditches, drainage features, and mature trees immediately adjacent to the existing travelway.
Photographs documenting each of these are attached as Collective Exhibit 7.
4. Strict Application of the Requirement Is Causing Substantial, Ongoing Hardship.
5. This Situation Was Not Caused by Any Act or Omission of the Applicants.
41468101vl
• A stream crossing and culvert along the route of Bo Lane, identified as waters of the United States,
the modification of which would likely require consent from the U.S. Army Corps of Engineers
and the Tennessee Department of Environment and Conservation;
• Private water lines serving three neighboring households, running along the entire southern edge
of Bo Lane, together with telephone and power lines and the utility easements of record at Book
1972, Pages 949 and 951;
Page 4
• A neighboring landowner’s active livestock operation - including fencing and a barn - bordering
the entire northern edge of Bo Lane; and
• Utility distribution poles set within the corridor, which can be relocated only by the utilities that
own them;
• A transmission line crossing Bo Lane, of record at Book 387, Page 561 and Book 392, Page 730,
such that widening would likely require approval from the Tennessee Valley Authority;
Absent relief, the Applicants cannot obtain building permits for a single-family residence through
the ordinary permitting process and cannot develop their 49-acre parcel in the reasonable manner that
Section 1.09(A) exists to permit. The hardship is not abstract or prospective - it is ongoing and concrete.
Equipment maintained on the Property (tractor, implements, trailer) remains exposed to the elements; water
must be manually hauled to the site; and the absence of permitted infrastructure limits the Applicants’
ability to care for, and provide predator protection for, their own livestock currently on the Property. Each
day the 16-foot requirement is strictly applied to a corridor the Applicants have no practical ability to widen,
this hardship compounds.
These conditions are exactly the “extraordinary, exceptional or unique situations” and “unusual
conditions” surrounding a parcel that Section 1.09(A) contemplates.
The Applicants did not create Bo Lane, were not a party to the 2001 survey that established the
easement and were not a party to the 2022 deed subdivision, which was effected by three completely
unrelated parties. The constraints described above are recorded interests and long-standing physical
conditions that predate the Applicants’ acquisition of the Property by more than two decades. Before
purchasing, the Applicants performed due diligence on the access requirements they understood to apply,
including the 50-foot easement width and the limitation on the number of lots served by the easement, both
of which are satisfied. Since acquiring the Property, they have worked cooperatively with County staff and
have satisfied every requirement identified, arriving at the 16-foot shared driveway width as the sole
outstanding item. While Section 1.09(A) does not expressly require it, the absence of any self-created
hardship further supports the equity of granting relief.
CONCLUSION
Sincerely,
MILLER & MARTIN, PLLC
By:
41468101vl
Williamson County Regional Planning Commission
Page 5
Accordingly, the Applicants respectfully request that the Planning Commission grant a variance
from the 16-foot shared driveway width requirement of Section 3.02(D)(2)(a) of the Sub Regs as applied
to the Property. We appreciate the Commission’s consideration and are available to answer any questions
or provide any additional information that would be helpful.
The Property presents extraordinary, exceptional and unique circumstances: a quarter-century-old
shared easement the Applicants have no practical ability to widen without displacing recorded rights held
by others, hemmed in by a transmission line, a stream crossing, neighbors’ private water and utility lines,
a neighboring livestock operation, utility poles, and mature trees. Strict application of the 16-foot width
requirement in these circumstances works substantial hardship and inequity - preventing the reasonable
development of a 49-acre parcel and imposing on a single owner the burden of improving a corridor shared
by many. At the same time, the public welfare remains fully protected: the Applicants have committed to
the sprinkler and building-envelope-separation alternative that the Sub Regs themselves treat as an adequate
substitute for the fire apparatus access standards, and Bo Lane will continue to function exactly as it has for
the surrounding community for 25 years.
A
Douglas Berry \ )
Direct Dial Number: (615) 744-86:
cc: Robert and Nicole Russell
Williamson County Zoning Attorney Kristi Ransom
EXHIBIT 1
***%
8
w in
V s
*P
LARRY U. TLF1NER
«-os amE
=z==BRRT=7H=E a===mtmeem"u
pet
yRbtsplly
c.-^b
EXHIBIT 2
(
This Instrument Prepared By: 4
NEW OWNER:
SAME
The actual consideration or value, whichever is greater, for this transfer is $60,000.00.
WARRANTY DEED
)
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
Part of:
Map 159
Parcel 11,
11.01 & 14.01
Being part of the same property conveyed to Larry U. Turner and wife, Catherine
D. Turner by warranty deeds of record in Book 320, page 413, Book 362, page 624,
Book 836, page 856 and Book 1045, page 191; and Book 496, page 415, Register’s
Office for Rutherford County, Tennessee.
Being Tract No. 8, of the Survey for Larry U. Turner Property, of record in Plat
Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat
Book 24, page 74, Register’s Office for Rutherford County, Tennessee, together with
that certain non-exclusive fifty (50’) feet wide ingress-egress and utility easement set
forth on said survey and the rights of use and obligations of shared maintenance
with Tract No. 9 shown on said survey.
Douglas S. Hale, Attorney /
HALE AND HALE, PLC
312 First Tennessee Bank Building
Franklin, Tennessee 37064
04/ Ur
VAFFIANT
For and in consideration of the sum of Ten Dollars, cash in hand paid by the
hereinafter named GRANTEES, and other good and valuable considerations, the receipt
and sufficiency of which is hereby acknowledged, LARRY U. TURNER and wife,
CATHERINE D. TURNER, hereinafter called the "GRANTORS", have bargained and sold
and by these present do transfer and convey unto TIMOTHY R. DOWELL and wife,
WENDY R. DOWELL and CHARLES E. S. RUSSELL and wife, ALISHA RUSSELL,
hereinafter called the "GRANTEES", their heirs and assigns, a certain tract or parcel of
land in Williamson and Rutherford County, Tennessee, described as follows, to-wit:
Sworn to and subscribed before me
this & t—day of May, 2001.
— . *
BK 2174 PG 312
Timothy R. Dowell, et al.
5/7 Newcastle n.
Hermi faqe ,7~ 37076
SEND TAX BILL TO: MAP & PARCEL
' "V _AQ —NOTARY PUBLIC
- 45, •5 ■ My Commission Expires: ( 2362
5. Utility Easement of record in Book 1972, page 949 and Book 1972, page
951, Register’s Office for Williamson County, Tennessee (as to easement).
6. Right of way for Taliferro Road (as to easement).
No commercial enterprises allowed.a.
b. Any residences of any type built on the property must have a minimum of
Double wide mobile homes and modular homes must have a minimum ofc.
d. Any extra buildings must set behind the main residence.
No single wide mobile homes allowed.e.
f. All buildings must be placed at least 25 feet off any side lines.
No swine or fowl will be permitted on any tract.g-
No abandoned and/or inoperable vehicles, junk or litter of any kind shallh.
be allowed outside any building. Property must be kept in a neat and orderly
way.
1800 square feet of actual living heated area on the main floor and must set back
a minimum of 500 feet from road right of ways.
GRANTEES ARE RESPONSIBLE FOR THE PAYMENT OF ANY ROLL
BACK TAXES ASSESSED UPON THE REAL PROPERTY DESCRIBED IN
THIS WARRANTY DEED.
1800 square feet of actual living heated area on the main floor and must set back
a minimum of 150 feet from road right of ways.
AND GRANTORS do covenant with the said GRANTEES that they are lawfully
seized and possessed of said land in fee simple, have a good right to convey it and the same
is unencumbered, except as follows:
TO HAVE AND TO HOLD the said tracts or parcels of land, with the
appurtenances, estate, title and interest thereto belonging to said GRANTEES, their heirs
and assigns, forever;
EK 2174 PG 313
3. Ingress-Egress and Utility Easement of record on the plan of Larry U.
Turner Property of record in Plat Book 31, page 103, Register’s Office for Williamson
County, Tennessee, and Plat Book 24, page 74, Register’s Office for Rutherford County,
Tennessee.
1. Williamson County taxes for the year 2001 are a lien against said property,
but are not yet due and payable. Part of Map 159, Parcels 11, 11.01 and 14.01.
2. All matters appearing on the plan of Larry U. Turner Property of record
in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat
Book 24, page 74, Register’s Office for Rutherford County, Tennessee.
4. Existing six (6") inch water line (as to easement).
7. The real property described in and conveyed by this Warranty Deed is
subject to those covenants and restrictions set forth herein below, which shall be
covenants running with the land and enforceable by the owners thereof through and
including April 21, 2021 on which date the same shall terminate and expire:
Witness my hand this day of May, 2001, in Franklin, Tennessee. V
-Notary/Public s
My Commission Expires:
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
Personally appeared before me, the undersigned, a Notary Public, in and for State
and County, Larry U. Turner and wife, Catherine D. Turner, the within named
bargainors with whom I am personally acquainted and who acknowledged that they
executed the foregoing instrument for the purposes therein contained. "
AND GRANTORS DO FURTHER covenant and bind themselves, their heirs and
assigns, to warrant and forever defend the title to the said land to the said GRANTEES,
their heirs and assigns, against the lawful claims of all persons whomsoever.
Larry U. Turner (
Catki U vll. S cbul
Catherine D. Turner
' * .
% .
?• F
33 l
WITNESS our hands this 8 day of May, 2001 in Franklin, Tennessee.
State of Tennessee, County of WILLIAMSON
Received for record the 08 day of
MAY 2001 at 3:46 PM. (RECA 416346)
Recorded in official records
Bock 2174 eases 312- 314
Notebook 66 Pase 486
State Tax $ 222.00 Clerks Fee $ 1.00,
Recordins $ 14.00, Total $ 237.00,
Resister of Deeds SADIE MADE
Deputy Resister PAMELA GREER
BK 2174 PG 314
EXHIBIT 3
This Instrument Prepared By:
NEW OWNER:
SAME
The actual consideration or value, whichever is greater, for this transfer is SI 40,000.00.
My Commission Expires: R/ 29 6
WARRANTY DEED
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
Part of:
Map 159
Parcel 11,
11.01 & 14.01
Being Tract Nos. 5 & 9, of the Survey for Larry U. Turner Property, of record in
Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat
Book 24, page 74, Register’s Office for Rutherford County, Tennessee, together with
that certain non-exclusive fifty (50’) foot wide ingress-egress and utility easement set
forth on said survey and the rights of use and obligation of shared maintenance with
Tract No. 8 shown on said survey.
Being part of the same property conveyed to Larry U. Turner and wife, Catherine
D. Turner by warranty deeds of record in Book 320, page 413, Book 362, page 624,
Book 836, page 856 and Book 1045, page 191; and Book 496, page 415, Register’s
Office for Rutherford County, Tennessee.
Douglas S. Hale, Attorney
Lhale AND HALE, PLC
312 First Tennessee Bank Building
Franklin, Tennessee 37064
TO HAVE AND TO HOLD the said tracts or parcels of land, with the
appurtenances, estate, title and interest thereto belonging to said GRANTEE, his heirs and
assigns, forever;
- 2 For: and in consideration of the sum of Ten Dollars, cash in hand paid by the
hereinafter named GRANTEE, and other good and valuable considerations, the receipt and
sufficiency of which is hereby acknowledged, LARRY U. TURNER and wife, CATHERINE
D. TURNER, hereinafter called the "GRANTORS", have bargained and sold and by these
present do transfer and convey unto L. HOOPER INMAN, unmarried, hereinafter called
the "GRANTEE", his heirs and assigns, certain tracts or parcels of land in Williamson and
Rutherford County, Tennessee, described as follows, to-wit:
L. Hooper Inman
Ro. Eex $72 _____Fzawtely 70 370657
orkootttic
Sworn to and subscribed before me
this © day of May, 2001.
RK 2174 PG 309
SEND TAX BILL TO: MAP & PARCEL
All matters appearing on the Survey for Larry U. Turner Property of2.
Ingress-Egress and Utility Easement of record on the plan of Larry U.3.
Utility Easement of record in Book 1972, page 949 and Book 1972, page5.
951, Register’s Office for Williamson County, Tennessee.
7. Existing six (6") inch water line, telephone line and power line.
8. Right of way for Taliferro Road.
9. The real property described in and conveyed by this Warranty Deed is
No commercial enterprises allowed.a.
Double wide mobile homes and modular homes must have a minimum ofc.
d. Any extra buildings must set behind the main residence.
No single wide mobile homes allowed.e.
f. All buildings must be placed at least 25 feet off any side lines.
No swine or fowl will be permitted on any tract.g-
h. No abandoned and/or inoperable vehicles, junk or litter of any kind shall
be allowed outside any building. Property must be kept in a neat and orderly
way.
record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee
and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee.
subject to those covenants and restrictions set forth herein below, which shall be
covenants running with the land and enforceable by the owners thereof through and
including April 21, 2021 on which date the same shall terminate and expire:
Turner Property of record in Plat Book 31, page 103, Register’s Office for Williamson
County, Tennessee, and Plat Book 24, page 74, Register’s Office for Rutherford County,
Tennessee.
GRANTEES ARE RESPONSIBLE FOR THE PAYMENT OF ANY ROLL
BACK TAXES ASSESSED UPON THE REAL PROPERTY DESCRIBED IN
THIS WARRANTY DEED.
1800 square feet of actual living heated area on the main floor and must set back
a minimum of 500 feet from road right of ways.
AND GRANTORS do covenant with the said GRANTEE that they are lawfully
seized and possessed of said land in fee simple, have a good right to convey it and the same
is unencumbered, except as follows:
BK 2174 FG 310
1. Williamson County taxes for the year 2001 are a lien against said property,
but are not yet due and payable. Part of Map 159, Parcels 11, 11.01 and 14.01.
4. Transmission Line Easement of record in Book 387, page 561 and Book
392, page 730, Register’s Office for Williamson County, Tennessee.
6. Subject to title to that portion of hte premises embraced within the bounds
of a cemetary with all rights of ingress and egress thereto.
b. Any residences of any type built on the property must have a minimum of
1800 square feet of actual living heated area on the main floor and must set back
a minimum of 150 feet from road right of ways.
/
lotary Public
4My Commission Expires:
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
Personally appeared before me, the undersigned, a Notary Public, in and for State
and County, Larry U. Turner and wife, Catherine D. Turner, the within named
bargainors with whom I am personally acquainted and who acknowledged that they
executed the foregoing instrument for the purposes therein contained.
00
Larry U. Turner
latiuun . out Ut
Catherine D. Turner
State of Tennessee. County of WILLIAMSON
Received for record the 08 day of
HAT 2001 at 3:46 PM. (RECI 416345)
Recorded in official records
Bock 2174 eases 309- 311
Notebook 66 Pase 486
State Tax $ 518.00 Clerks Fee $ 1.00,
Recordins $ 14.00, Total $ 533.00,
Resister of Deeds SADIE WADE
Deputy Resister PAMELA GREER
Witness my hand this < day of May, 2001, in Franklin, Tennessee;
AND GRANTORS DO FURTHER covenant and bind themselves, their heirs and
assigns, to warrant and forever defend the title to the said land to the said GRANTEE,
his heirs and assigns, against the lawful claims of all persons whomsoever.
WITNESS our hands this 8 day of May, 2001 in Franklin, Tennessee.
BK 21’7 4 PG 311
EXHIBIT 4
Book 9821 Page 514
WARRANTY DEED
(
SEE
File No.: 2025-1413
ADDRESS NEW OWNER(S) AS FOLLOWS: MAP/PARCEL NO(S).SEND TAX BILLS TO:
(NAME) (NAME)
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
Spring
(CITY)
Spring
(CITY)
Land in Williamson County, Tennessee, being a portion of Lot No. 4A on the Plan of Minor Revision of Lot
4, Larry U. Turner Property of record in Plat Book P44, Page 104, Register's Office for Williamson County,
Tennessee, and more particularly described as follows:
THE ACTUAL CONSIDERATION OR VALUE, WHICHEVER
IS GREATER, FOR THIS TRANSFER IS $590,000.00.
SUBSCRIBED AND SWORN TO BEFORE ME, THIS THE
28TH DAY OF AUGUST, 2025.
FOR AND IN CONSIDERATION OF THE SUM OF Five Hundred Ninety Thousand And No/100 Dollars
($590,000.00), CASH IN HAND PAID BY THE HEREINAFTER NAMED GRANTEE, AND OTHER GOOD
AND VALUABLE CONSIDERATIONS, THE RECEIPT OF WHICH IS HEREBY ACKNOWLEDGED, l/WE,
ZACHARY J. BARBER AND TIFFANY J. BARBER, HUSBAND AND WIFE, HEREINAFTER CALLED
THE GRANTOR, HAVE BARGAINED AND SOLD, AND BY THESE PRESENTS DO TRANSFER AND
CONVEY UNTO ROBERT PAUL RUSSELL AND NICOLE DANIELLE RUSSELL, HUSBAND AND
WIFE, HEREINAFTER CALLED THE GRANTEE, THEIR HEIRS AND ASSIGNS, A CERTAIN TRACT OR
PARCEL OF LAND IN WILLIAMSON COUNTY, STATE OF TENNESSEE, DESCRIBED AS FOLLOWS,
TO-WIT:
39 Watertree Ct
(ADDRESS)
39 Watertree Ct
(ADDRESS)
Parcel ID(s): 159-011.04 (IN
GREENBELT)
Robert Paul Russell and Nicole
Danielle Russell
Robert Paul Russell and Nicole
Danielle Russell
THIS INSTRUMENT WAS PREPARED BY
Mid-State Title & Escrow, Inc.
128 Holiday Ct., Ste. 125, Franklin, TN 37067
(*enss
Affiant
z0""M4, I \
I PUBLIC — I
NvyooK
TX 77380
(STATE) (ZIP)
Notary Public .
MY COMMISSION EXPIRES: | Opi
(AFFIX SEAL) C)
TX 77380
(STATE) (ZIP)
Book 9821 Page 515
Thence. South 89 degrees 49 minutes 32 seconds East, a distance of 310.49 feet to an iron rod found;
Thence. South 70 degrees 35 minutes 10 seconds East, a distance of 236.69 feet to an iron rod set;
Thence. North 75 degrees 43 minutes 42 seconds East, a distance of 541.37 feet to an iron rod set;
Thence. North 80 degrees 43 minutes 31 seconds West, a distance of 122.94 feet to an iron rod found at
the northeast corner of property conveyed to Michael Ruggiero etux Renee as of record Deed Book 1580,
Thence, following the north boundary of Caukin and Tomlin, South 73 degrees 13 minutes 43 seconds
West, a distance of 197.64 feet to an iron rod set;
Thence, South 79 degrees 53 minutes 25 seconds East, a distance of 775.94 feel to an iron rod found at
the southeast corner of Benning property and on the south boundary of property conveyed to Dennis P.
Milnar etux Constance J. as of record in Warranty Book 77, Page 176, in the Register's Office of
Rutherford County, Tennessee;
Thence, South 79 degrees 52 minutes 43 seconds East, a distance of 13.07 feet to an iron rod set at the
true Point of Beginning;
Thence, continuing with the south boundary of Benning, South 79 degrees 52 minutes 43 seconds East, a
distance of 205.66 feet to an iron rod found:
Thence, leaving Swafford boundary and following the west and south boundaries of Benning, South 08
degrees 27 minutes 20 seconds West, a distance of 185.18 feet to an iron rod set;
Thence, South 79 degrees 53 minutes 34 seconds East, a distance of 1,019.00 feet to an iron rod set on
the west boundary of property conveyed to Thomas R. and Donna P. Benning as of record in Deed Book
5060, Page 718, in the Register's Office of Williamson County. Tennessee, said rod being the southeast
comer of said Swafford property;
Thence, following said east margin of Taliaferro Road, North 12 degrees 06 minutes 18 seconds West, a
distance of 255.98 feet to an iron rod set at the southwest comer of property conveyed to William S. and
Laura F. Swafford as of record in Deed Book 7520, Page 170, in the Register's Office of Williamson
County, Tennessee, said rod being the northwest corner of the herein described property:
Being an eastern 49.13-acre portion of the Martha N. and Thomas E. Stacy property that is described in
Deed Book 3925, Pages 754-755, in the Register's Office of Williamson County, Tennessee and shown
as Part Of Parcel 159-011.03 on Williamson County Tax Maps, and more particularly described as
follows:
Thence. South. 19 degrees 44 minutes 07 seconds East, a distance of 778.05 feet to a fence post on the
north boundary' of property conveyed to Jack W. Caukin and Charles W. Tomlin as of record in Deed
Book 1968, Page 1835, in the Register's Office of Rutherford County, Tennessee;
Thence, following south boundary of Milnar, South 80 degrees 50 minutes 21 seconds East, a distance of
1,337.20 feet to a fence post;
Thence, leaving said east margin and following the south boundary of Swafford property, South 79
degrees 05 minutes 56 seconds East, a distance of 420.24 feet to an iron rod found;
Commencing at an iron rod set on the east margin of Taliaferro Road at a cedar tree at the northwest
comer of property conveyed to Tommy and Natalie Henley as of record in Deed Book 5409. Page 433, in
the Register's Office of Williamson County, Tennessee, said rod being the southwest corner of the herein
described property;
Book 9821 Page 516
Page 2695, in the Register's Office of Rutherford County, Tennessee;
Thence, South 00 degrees 11 minutes 25 seconds East, a distance of 199.90 feet to an iron rod found:
Thence. North 43 degrees 12 minutes 00 seconds West, a distance of 302.37 feet to an iron rod set;
Containing 2,140,267 square feet of 49.13 acres.
Thence, following the north boundary of Ruggiero and the north boundary- of the aforementioned Henley
property. North 86 degrees 01 minutes 40 seconds West, a distance of 2,036.49 feet to an iron rod found;
TO HAVE AND TO HOLD the said tract or parcel of land, with the appurtenances, estate, title and interest
thereto belonging to the said GRANTEES, their heirs and assigns forever; and we do covenant with the
said GRANTEES that we are lawfully seized and possessed of said land in fee simple, have a good right
to convey it and the same is unencumbered, unless otherwise herein set out; and we do further covenant
and bind ourselves, our heirs and representatives, to warrant and forever defend the title to the said land
to the said GRANTEES, their heirs and assigns, against the lawful claims of all persons whomsoever.
Wherever used, the singular number shall include the plural, the plural the singular, and the use of any
gender shall be applicable to all genders.
Being a portion of the same property conveyed to Martha N. Stacy and Thomas E. Stacy by Quitclaim
Deed from Frank Latimer and his wife, Cynthia Latimer of record in Book 3925, Page 754, in the
Register's Office for Williamson County, Tennessee, dated May 24, 2006 and recorded on May 31, 2006
and in Book 627, Page 3430, in the Register's Office for Rutherford County, Tennessee, dated May 24,
2006 and recorded on June 5, 2006.
Thence, leaving said north boundary of Henley and following a new line through the parent parcel, North
00 degrees 02 minutes 32 seconds WEST, a distance of 993.21 feet to the Point of Beginning.
Being the same property conveyed to Zachary J. Barber and Tiffany J. Barber, husband and wife by
Warranty Deed from Martha N. Stacy and Thomas E. Stacy, married to each other of record in Book 9162,
Page 90, in the Register's Office for Williamson County, Tennessee, dated December 08, 2022 and
recorded on December 13, 2022, and also of record in Book 2305, Page 1276, in the Register's Office for
Rutherford County, Tennessee, recorded on December 13, 2022. Deed of Correction of record in Book
9213, Page 390, in the Register's Office for Williamson County, recorded on March 15, 2023, and also of
record in Book 2326, Page 1043, in the Register's Office for Rutherford County, Tennessee, recorded on
March 15, 2023.
Subject to: This conveyance is subject to the matters set forth below, if any, as well as any and all zoning
regulations, building restrictions, setback lines, conditions, covenants, and restrictions (as may be
amended or supplemented), all easements, utility easements or rights of ways for public utilities that
appear in the appropriate public records. Property taxes have been prorated and the Grantee has
assumed payment thereof when same become due and payable. Taxes for the year 2025, a lien not yet
due and payable.
TOGETHER WITH a 25' access easement for ingress/egress as shown on the plats of record in Plat
Book 44, Page 104, Plat Book 42, Page 114, and Plat Book 31, Page 103, in the Register's Office for
Williamson County, Tennessee.
unimproved 0
This is improved • property, known as 0 Bo Lane / Taliaferro Road, Eagleville, TN 37060________
(House No.) (Street) (P.O. Address) (City or Town) (Postal Zip)
Book 9821 Page 517
,2025.day of
, 2025, before me personally appeared Zachary J. Barber and
2-
Tiffany J. Barber, to me known t^be the person (or persons) described in and who executed the foregoing
instrument, and acknowledged that such person (or persons) executed the same as such person (or
person's) free act and deed.
Notary Public
uqll
/
. "blic 8 J SA -00* <,M
fkvon CoR
' YSt tUVV
915546 64, oltW,
/ State % • ' , or ' 2 s
Onnes3.. ) £ NVotar j =
My Commission Expires: 3 23 2 7
Witness our hands this 0-
_= 6-- Zachary J. Barber
0/ 3 Be "977J 0er
STATE OF TENNESSEE
COUNTY OF WILLIAMSON
On this &+ day of (
Book 9821 Page 518
True Copy Certification
Affiant Signature
&X , 2025
/
2025.
-
. A <-
25029001
State of Tennessee
County of Williamson
I, Yvette Meldrum, do hereby make oath that I am a licensed attorney and/or the custodian of the original
version of the electronic document tendered for registration herewith and that this electronic document is a
SHERRY ANDERSON
REGISTER OF DEEDS
BK/PG: 9821/514-518
25029001
0.00
2183.00
25.00
2.00
1.00
2211.00
IAMSON COUNTY
State
. i
fonnessec
Notary
. Public ,
true and exact copy of the original document executed and authenticated according to law on
WMJ QX_____2025.
(L (77
" 1
„d26l/19/) 3* q SWs ,
$ 620 7s.
5 PGS : DEED
ELIZABETH LYNCH 1062855
09/08/2025 - 11:28:33 AM
MORTGAGE TAX
TRANSFER TAX
RECORDING FEE
DP FEE
REGISTERS FEE
TOTAL AMOUNT
STATE OF TENNESSEE, WI
maenoo
‘ 5 4/ i 11 i V * "
MY COMMISSION EXPIRES; 300 0 7
Sworn to and subscribed before me this O% of
22122
Notary's Signature' "
EXHIBIT 5
Prepared For
McMahon's Steel Erections LLC
Description TotalRate
$150,000.00
Subtotal $150,000.00
Total $150,000.00
Zach McMahon Paul Russell
Bo Lane Widening
Approx 3200 Linear ft x 4’
MCMAHONS STEEL ERECTIONS
EXTERIOR EXCELLENCE
Estimate #
Date
Paul Russell
(270) 210-2039
138 Dalton Cir
Hendersonville, Tn 37075
Phone: (615) 663-4731
Email: zachmcmahon@rocketmail.com
Water Line relocation where pertinent
Fence relocation where necessary
Culvert pipes to support the wider road
Excavation of new drainage ways
3-4" rock base approximately 10"
10" crusher run
1379
07/29/2026
Pa: 1
$150,000.00 $150,000.00
EXHIBIT 6
G P
15 April 2026
Williamson County Planning Office
Re: Variance Request — Bo Lane, Williamson County (Fire Service Access)
TI: BZA Members
Background and Inspection
Decision and Conditions
<0
Because of the existing conditions and the serious safety risks they pose to emergency
responders and the public, I again declined to grant a fire-access variance.
• The property owner then proposed providing a 12-foot-wide travelway with intermittent pull-
offs. I indicated that such a plan would be acceptable in principle but that I would not grant a
variance until the improvements were completed and physically in place ("on the ground").
I declined the variance based on that report. At the owner's request, I personally inspected the
road two days later.
• During my inspection I observed that Bo Lane is a narrow gravel road with deep ditches on both
sides and numerous deep ruts and potholes along the access. Although the road widens in a few
locations, the presence of the ditches leaves virtually no safe area for a fire apparatus to pull off
to allow another emergency vehicle to pass.
I am writing to put in writing my observations, conclusions, and concerns regarding the Bo Lane area of
rural Williamson County and the recent request for a fire-access variance for a proposed residential
building on that road.
• At the request of a new property owner seeking a variance from the Fire Service, I initially
directed a fire captain to inspect Bo Lane. The captain reported the road to be in poor condition.
Williamson Fire/Rescue
J.R.Bonson, Coordinator
304 Beasley Drive
Franklin, Tennessee 37064
(615) 790-5757 Office (615) 417-9241 Cell
Jav.Bonson@WilliamsonCounty-In.gov
SB “adamass,”
Safety Concerns and Precedent
Availability for Further Information
Respectfully,
J.R. Bonson
Please feel free to contact me at [phone number] or [email address] for any additional
information or to arrange a follow-up inspection.
• I regret that I cannot present this letter in person; I am traveling on business this week. A
colleague from the Fire Service is available to provide further clarification regarding emergency
traffic and operational concerns if needed.
• I expressed empathy for the property owner's situation and suggested it would be equitable for
neighbors or county government to share in the cost of required improvements rather than
placing the entire financial burden on a single property owner.
• I also informed the owner that, within weeks of my initial visit, a nearby residential structure fire
suffered a complete loss in part because of access issues and inconsistent water delivery
attributable to a similar access road. I personally observed a Rutherford County fire apparatus
nearly overturn while negotiating that road. These events underscore the genuine danger posed
to firefighters and other emergency personnel when access and apparatus operations are
compromised.
COLLECTIVE
EXHIBIT 7
Photo 2Regulatory Constraints
(No ability to modify road in these areas without additional regulatory approvals)
(Dotted red line representing approximate portion of Bo Lane where fee ownership of land along the northern and
southern borders is owned by others)
Aerial View of Bo Lane and Approximate Property Line Photo 1
.a
Oas
Photo 3
Constraints Applicable to Both Sides of Bo Lane
(Stream crossing)
MEs Jha.aH
(Local utility poles)
i
Photo 4
Photo 5
(Drainage features and ditches)
(Private water meter for 3 private water lines running alongside southern edge of Bo Lane)
Additional Constraint Applicable to Southern Side of Bo Lane Photo 6
fife fEha
‘8-7 p s en
tir ‘ass
Photo 8
(Mature vegetation)
(Neighbor’s existing barn along northern edge of Bo
Lane)
Additional Constraints Applicable to Northern Side of Bo Lane
Photo 7
(Neighbor's livestock fencing) p r noio y
—esi1 isar
- s d —a
f -
Photo 10
(Start of Bo Lane off of Taliaferro Road)
Photo 11
(Driveway to subject property)
.95
■
=- -Cde
■
eoe Pg-se. -
e . se — . ••
-
■
Item 14—Page 1 of 1
Reviewer: AVH
Date: 8/13/2026
ITEM 14
SITE PLAN REVIEW FOR CREWS RUNWAY , ON 1,137.13 ACRES LOCATED OFF
BOY SCOUT ROAD IN THE 1ST VOTING DISTRICT (5-2026-004).
Attachment 14-1 Site Plan
14-2 Aerial Photograph
14-3 Staff Report for BZA Meeting of June 2026
Area 1,137.13 acres
Zoning Rural Preservation-5 (RP-5)
Water HB&TS Utility District
Development Option Private Landing Strip
Chapter 1101 Status Rural
Maps and Parcels 074---1.03, 1.04, 1.06, 1.07 and 1.08
094---033.03
095---018.03
File Number (5-2026-004)
In June 2026 the Board of Zoning Appeals (BZA) granted a Special Use Permit to allow a
Private Landing Strip that is accessory to a residential use on the property in question ,
and a Variance to allow disturbance of slopes in excess of twenty -five (25) percent in
order to construct the private landing strip .
The applicant is now requesting Site Plan approval for the runway and the runway’s
associated buildings. This new runway will replace an existing 1,800 -foot grass runway,
which will be allowed to return to its natural state and be used as a hay field. According
to the Site Plan, the runway will measure 3,000 feet in length and be sixty-five (65) feet
in width. The r unway will be paved, and the applicant proposes to construct a 10,000 -
square foot hanger for storage of the two (2) aircraft that will utilize the property, a
1,600-square foot storage building, and a 336 -square foot fuel shed. There will be no
commercial use of the runway. It should be noted there are seven (7) separate parcels
that make up the subject properties and will be consolidated into a single property via a
newly recorded deed.
The Williamson County Department of Sewage Disposal Management has r eviewed the
application and approved the request. Primary access to the proposed runway is via an
easement through the County’s Landfill, and the Tennessee Department of Transportation
has granted conceptual approval for access onto Pinewood Road for this use. A
Photometrics Plan and a Landscaping Plan with the appropriate buffers have been
submitted and approved.
The Site Plan is in order, and Staff recommends approval.
COVER
C-0.0
LOCATION MAP
1" = 3,000'
SITE PLAN
FOR
CREWS PROPERTY
PRIVATE AIRSTRIP RUNWAY
MAP 074, PARCELS 1.02, 1.03, 1.04, 1.06, 1.07, 1.08
MAP 094, PARCEL 33.02 AND MAP 095, PARCEL 18.03
WILLIAMSON COUNTY, TENNESSEE
SITE
DEVELOPER: CHARLES CREWS
5600 BOY SCOUT ROAD
ENGINEER: T-SQUARE ENGINEERING
111 SOUTHEAST PARKWAY CT
FRANKLIN, TN 37064
SHEET SCHEDULE
C-0.0 COVER SHEET
C-1.0 OVERALL EXISTING CONDITIONS
C-2.0 OVERALL SITE PLAN
C-2.1 DETAILED SITE PLAN / GRADING
C-2.2 PLAN AND PROFILE
C-3.0 INITIAL AND TEMPORARY EROSION CONTROL PLAN
C-3.1 PERMANENT EROSION CONTROL PLAN
C-3.2 EROSION CONTROL DETAILS
C-4.0 PREDEVELOPMENT STORMWATER PLAN
C-4.1 POSTDEVELOPMENT STORMWATER PLAN
C-8.0 DETAIL SHEET
DATE
T-SQUARE
drawn by:
as shown
scale:
7/20/26
date: NO. REVISIONS
NSM
reviewer:
SroMect
sheet
T-SQUAREENGINEERING
APPLICANT
T-SQUARE ENGINEERING
111 SOUTHEAST PARKWAY COURT
FRANKLIN, TN 37064
615.678.8212
CREWS RUNWAY
5600 BOY SCOUT ROAD
WILLIAMSON COUNTY, TENNESSEE
OWNER OF RECORD
CHARLES AND KIMBERLY CREWS
555 GREAT CIRCLE ROAD
NASHVILLE, TN 37228
MAP 074, PARCELS 102, 103, 104, 106, 107, 108
MAP 094, PARCEL 33.02 AND MAP 095, PARCEL 1803
23-0342
7/20/2026
FLOOD NOTE
A PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS "ZONE AE" AS
EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED
09/29/2006.
NOTE:
THE WILLIAMSON COUNTY BOARD OF ZONING APPEALS GRANTED A SPECIAL USE PERMIT FOR THE
PRIVATE LANDING STRIP; THEY ALSO GRANTED A VARIANCE ALLOWING FOR DISTURBANCE OF
STEEP SLOPES ON JUNE 25, 2026.
P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 0 Cover Sheet.dwg, 7/20/2026 12:40:56 PM
ATTACHMENT 14-1A
PC 12
OVERALL SITE PLAN
C-2.0
DATE
T-SQUARE
drawn by:
as shown
scale:
7/20/26
date: NO. REVISIONS
NSM
reviewer:
SroMect
sheet
T-SQUAREENGINEERING
CREWS RUNWAY
5600 BOY SCOUT ROAD
WILLIAMSON COUNTY, TENNESSEE
23-0342
7/20/2026
( IN FEET )
GRAPHIC SCALE
0 500 1000500 250
SCALE: 1" = 500'
100 YEAR FLOOD PLAIN
APPROXIMATE LOCATION
PER FEMA FLOOD PLAIN
PANEL NOTED ABOVE
200FT FROM EDGE OF RUNWAY
1,000FT FROM
EDGE OF RUNWAY
1,000FT FROM
EDGE OF RUNWAY
WILLIAMSON COUNTY LANDFILL
(NON-RESIDENTIAL)
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
200FT FROM EDGE OF RUNWAY
P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 2 Site Plan.dwg, 7/20/2026 12:54:46 PM
ATTACHMENT 14-1B
920
860
870
880
890
900
910
920
880
890
900
910
870
880
890
900
910
870
880
890
900
910
910
920
920
910
910
900
910
900
910
900
910
890
900
840
850
860
870
880
920
930
890
900
920
930
890
900
910
850
860
870
880
910
920
920
860
870
880
890
900
910
920
920
850860870880890900910
850
860
870
880
890
900
910
910
910
910
910
890
900
850
860
870
880
890
900
860
870
880
890
900
840
850
860870
880
890
900
860
870
880
890
900
910
840
850 860
870
880
890
900
910
920
890
900
910
920
BP: 0+00.00
EP: 40+00.00
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00
870
880
890
900
910
910
912
914
920
924924
860
870
880
890
900
910
920
920
910
920
904
906
908
912
914
916
918
PC 12
900
910
910
920
910
920
910
920
910
910
920
900
910
920
930
886
888
890
892
894
896
898
900
902
904
906
908
910
908
910912
914
916
918
920
922
924
926
31+00
32+00
33+00
34+00
35+00
PC 12
ST-HW4
INV OUT: 894.49
102' of 18" RCP @ 1.00%
ST-HW3
INV IN: 895.50
900
910
896
898
902
904
906
908
900
910
898
902
904
906
908
912
914
916
910
920
906
908
912
914
916
918
922
924
926
910
920
904
906
908
912
914
916
918
910
920
904
906
908
912
914
916
918
922
924
926
904
904
906
-1.0%
904.00
904.00
-1.2%-2.0%
-1.0%
DATE
T-SQUARE
drawn by:
as shown
scale:
7/20/26
date: NO. REVISIONS
NSM
reviewer:
SroMect
sheet
T-SQUAREENGINEERING
CREWS RUNWAY
5600 BOY SCOUT ROAD
WILLIAMSON COUNTY, TENNESSEE
23-0342
7/20/2026
( IN FEET )
GRAPHIC SCALE
0 250 500250 125
SCALE: 1" = 250'
DETAILED SITE PLAN / GRADING
C-2.1
( IN FEET )
GRAPHIC SCALE
0 30 6030 15
SCALE: 1" = 30'
SEE INSET RIGHT
12FT X 28FT FUEL SHED
100FT X 100FT HANGAR
10,000 SF
PARKING
PRIVATE INGRESS/EGRESS
PRIVATE INGRESS/EGRESS
16FT GRAVEL ROAD
16FT GRAVEL ROAD
RUNWAY (65FT X 3,000FT)
200FT FROM EDGE OF RUNWAY
200FT FROM EDGE OF RUNWAY
1000FT FROM EDGE OF RUNWAY
1000FT FROM EDGE OF RUNWAY
NOTES:
1) THE PROPOSED USE FOR THIS SITE IS: AIRPORT, LANDING STRIP, PRIVATE
2) CURRENT ZONING OF ALL PROPERTY: RURAL PRESERVATION - 5
3) NO HELIPORT WILL BE CONSTRUCTED; NO HELICOPTERS WILL BE USED ON THIS SITE
4) THERE IS AN EXISTING GRASS RUNWAY ON 5600 BOY SCOUT ROAD THAT WILL BE ABANDONED UPON COMPLETION OF THE NEW
RUNWAY
5) ALL STRUCTURES/HANGARS ARE TO BE 100FT FROM ANY PROPERTY LINE
6) THE ENDS OF THE RUNWAY ARE TO BE 1000FT FROM ANY PROPERTY LINE; THE SIDES OF THE RUNWAY ARE TO BE 200FT FROM ANY
PROPERTY LINE. NO AIRCRAFT WILL BE HANGARED, TIED DOWN OR PARKED WITHIN THE SETBACKS
7) THE MAX HEIGHT OF THE STRUCTURES ON THE PROPERTY SHALL BE SUBJECT TO FEDERAL AVIATION ADMINISTRATION, PART 77
8) NO COMMERCIAL ACTIVITY WILL BE CONDUCTED IN CONJUNCTION WITH THIS RUNWAY
9) OWNER TO ABANDON THE EXISTING GRASS RUNWAY AFTER COMPLETION OF THIS PROPOSED RUNWAY; GRASS RUNWAY TO BE
CONVERTED TO HAY FIELD
10) TWO (2) AIRCRAFTS WILL BE PARKED ON THE SITE.; ONE (1) AIRCRAFT WILL BE PARKED ON THE APRON, AND ONE (1) WILL BE PARKED
INSIDE THE HANGAR.
40'
100'
120'
102.3'
334.5'
CONCRETE LINED
DITCH WHERE APPLICABLE
AIRSTRIP PAVEMENT TO BE IN
ACCORDANCE WITH GEOTECHNICAL
ENGINEER AND/OR FAA SPECIFICATIONS
STORAGE
1,600 SF
500' SAFETY APPROACH;
GRASS
500' SAFETY APPROACH;
GRASS
WILLIAMSON COUNTY LANDFILL
(NON-RESIDENTIAL)
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
NO RESIDENTIAL STRUCTURE
LOCATED ON PARCEL
200'
423'
1000'
1000'
HEAVY DUTY
CONCRETE SECTION
HEAVY DUTY
ASPHALT SECTION
69.1'
200'
70'
192'
52'
100'
50' WATERWAYNATURAL AREA
25' DRAINAGEWAYEASEMENT
50' WATERWAY
NATURAL AREA
25' DRAINAGEWAY
EASEMENT
25' DRAINAGEWAY
EASEMENT
TYPICAL SECTION
N.T.S.
32.5'32.5'
3:1 SLOPE
3:1 SLOPE
279'
1127'
P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 2 Site Plan.dwg, 7/20/2026 12:41:32 PM
ATTACHMENT 14-1C
ATTACHMENT 14-3
Item 3--Page 1 of 3
Reviewer: AVH
Date: 9-26-2024
ITEM 6
A REQUEST BY NATHAN MCVEY OF T -SQUARE ENGINEERING (CHARLES
CREWS, PROPERTY OWNER) FOR A SPECIAL USE TO ALLOW A PRIVATE
LANDING STRIP AND A VARIANCE FOR A DISTURBANCE OF STEEP SLOPES.
THE PROPERTIES ARE LOCATED AT 5600 BOY SCOUT ROAD (MAP 74, PARCELS
1.02, 1.03, 1.04, 1.05, 1.06, 1.07 AND 1.08, MAP 94, PARCEL 33.02, AND MAP 95,
PARCEL 18.03), ARE ZONED RURAL PRESERVATION-5 (RP -5) AND LOCATED IN
THE 1
ST VOTING DISTRICT (5-2026-004)
Attachment 6-1 Site Plan
6-2 Aerial Photograph
6-3 Site Photographs
6-4 Letter of Intent
6-5 Minutes from January 2001 Planning Commission Meeting
6-6 Section 5.01: Special Uses
6-7 Section 11.04 (D)(16): Landing Strip and Helipad, Private
6-8 Section 5.02: Variances
6-9 Section 13.03 (B): Steep Slopes
6-10 Applicant’s Slope Exhibit
Area 1,190 acres
Zoning Rural Preservation-5 (RP-5)
Water HB&TS Utility District
Development Option Private Landing Strip
Chapter 1101 Status Rural
Maps and Parcels 074---1.02, 1.03, 1.04, 1.05, 1.06, 1.07 and 1.08
094---033.03
095---018.03
File Number (5- 2026-004)
In January 2001 the Williamson County Regional Planning Commission granted a Conditional
Use Permit to allow a Private Landing Strip on a portion of this property which totals
approximately 186 acres (See Attachment 6 -5). The applicant has resided on the property
and operated the 1,800-foot grass runway on since that time.
In November of 2025 the County Commission revised the Zoning Ordinance to allow private
landing strips such as this.
The applicant is requesting approval of a private landing strip that is accessory to a residential
use in order to relocate the existing runway to a more suitable location. According to the Site
Plan and Letter of Intent, the runway will measure 3,000 feet long, be sixty-five (65) feet in
width, and will replace the existing 1,800-foot runway (See Attachment 6-4). The runway will
be paved, and the applicant proposes to construct a 10,000- square foot hanger for storage
of the two (2) aircraft that will utilize the property, a 1,600-square foot storage building, and a
Item 6—Page 2 of 3
Reviewer: AVH
BZA Date: 6-25-2026
336-square foot fuel shed. The existing runway will be allowed to return to its natural state
and be used as a hay field. There will be no commercial use of the runway. It should be
noted there are nine (9) separate parcels that make up the subject proper ties, and it will be
necessary for those properties to be consolidated into a single property via a newly recorded
deed. The recordation of this new deed has been made a condition of approval.
The Williamson County Department of Sewage Disposal Management has reviewed the
application and approved the request. Primary access to the proposed runway is via an
easement through the County’s Landfill , and the Tennessee Department of Transportation
has granted conceptual approval for access onto Pinewood Road for this use.
The proposed use will comply with the Zoning Ordinance so long as the nine (9) parcels are
consolidated into a single parcel, and the Board finds in its evaluation that the standards of
Section 5.01 have been met. A Landscaping Plan with the appropriate buffers shown is under
review by Staff. Outside of the lighting requirements of the Federal Aviation Administration
(FAA), the runway will not be illuminated, and therefore a Photometrics Plan is not required.
Section 5.01 of the Zoning Ordinance outlines the Board’s responsibilities while reviewing
Special Uses, and Subsection E outlines the Review Standards that should be considered
when evaluating Special Uses (See Attachment 6-6). During its deliberations, the Board will
need to make a finding as to whether the proposed Private Landing Strip meets the standards
of Section 5.01(E) of the Zoning Ordinance.
The Site Plan (See Attachment 6-1) included in the packet is for illustrative purposes only and
is under review for compliance. As the total square footage of all proposed buildings is greater
than 5,000 square feet, the Planning Commission will review the Site Plan.
The Board must determine if the use is appropriate in this location based on the standards
outlined in the following sections:
1.) Section 5.01 (E); and
2.) Section 11.04 (D)(16) of the Zoning Ordinance.
In order to construct the runway, the applicant will disturb slopes in excess of twenty-five (25)
percent. The Zoning Ordinance defines slopes in excess of twenty-five (25) percent as Very
Steep Slopes, and Section 13.03 (B)(5): General Prohibition of Land Disturbance prohibits
clearing, excavation, and grading, among others, on Very Steep Slopes (See Attachment 6-
9). The applicant is requesting a variance from the aforementioned Section in order to
construct the runway. Attachment 6-10 illustrates the locations of the Very Steep Slopes that
will be disturbed in order to construct the runway.
Staff recommends approval of the Special Use with the following stipulations:
1.) Recording of a deed consolidating the nine (9) properties that make up the subject
properties;
Item 6—Page 3 of 3
Reviewer: AVH
BZA Date: 6-25-2026
2.) Execution of a Stormwater Maintenance Agreement and submission of an Operation
and Maintenance Plan for stormwater improvements;
3.) Submittal to and approval by the County Engineer of both the stormwater calculations
and the grading and drainage plan; and
4.) All signage must be approved per Ordinance requirements.
Variances are subject to the provisions delineated in Article 5, Section 5.02 of the Zoning
Ordinance (See Attachment 6 -8), and more specifically, the standards outlined in Section
5.02(F).
Item 15—Page 1 of 1
Reviewer: OCW
Date: 8/13/2026
ITEM 15
SITE PLAN REVIEW FOR WYELEA FARMS – THE S TABLES, ON 53.70 ACRES
LOCATED OFF DEL RIO PIKE IN THE 9TH VOTING DISTRICT (5-2026-005).
Attachment 15-1 Site Plan
15-2 Aerial Photograph
Area 53.70 acres
Zoning Rural Development – 5 (RD-5)
Water City of Franklin
Sewer Nontraditional Wastewater Treatment and Disposal System
Development Option Country Club
Chapter 1101 Status Rural
File Number (5-2026-005)
The applicant is requesting Site Plan approval for the Wyelea Farms Stables , which is
classified as a Country Club. As the Stables are larger than 5 ,000 square feet, it is
considered a Major Site Plan and requires Planning Commission approval.
Because the Stables are proposed to be located within required Open Space, the
Homeowner’s Association must maintain ownership of the Stables.
The facilities, which are located in Open Space, consist of a Club House, Stables, Sheds,
Warehouse, Maintenance Building, and an Indoor Riding Arena.
The requirements of Section 11.03 (D)(21) have been met. A Landscaping Plan has been
submitted and approved by Staff. A water bond is not required , as the Stables was
included in Section 1.
The Site Plan is in order, and Staff recommends approval with the following conditions:
1. Per the recommendation of the County’s Wastewater Consultant, the posting of a
Performance Bond for the Collection System in the amount of $ 242,000; and
2. The Homeowner’s Association must maintain ownership of the Stables; and
3. Execution of a Performance Agreement for the above referenced sureties.
WYELEA FARMS
THE STABLES
3021 DEL RIO PIKE
WILLIAMSON COUNTY, TN 37069
C0.00
DESCRIPTION
INDEX OF DRAWINGS
COVER SHEETC0.00
C0.01
C9.01 SITE DETAILS
LEGEND & NOTES
SHEET NO.
OVERALL SITE PLAN
SITE PLAN
EROSION CONTROL PLAN
UTILITY PLAN
EXISTING CONDITIONS PLAN
GRADING & DRAINAGE PLAN
C1.00
C3.00
C4.00
C5.00
C6.00
C2.00
DETAILED UTILITY PLANC6.11
C4.10
COVER SHEET
PROJECT
SITE
© 2025 Collected Civil Engineering, LLC
All rights reserved. copy or reproduction of this drawing or
document, or any portion thereof, without the express
written permission of Collected Civil Engineering, LLC. is
prohibited. This drawing or document is not intended or
represented to be suitable for any purpose other than the
specific project, application and situation for which it was
intended. Any modification of this drawing or document, or
any use for any project, application or situation other than
that for which it was intended, will be at user's sole risk and
without liability to Collected Civil Engineering, LLC.
Except as provided by rule 0120-02-.08(5)(b) of the
Tennessee state board of architecture and engineering
examiners, any changes made to this drawing or document,
after final revision and sealing by the registrant are
prohibited by any person other than the profession
registrant, including but not limited to owners/clients,
contractors, subcontractors, other design professional or any
of their agents, employees or assigns.
DRAWING NAME:
DRAWING NUMBER:
WYELEA FARMS
THE STABLES
3021 DEL RIO PIKE
WILLIAMSON COUNTY, TN 37069
7/20/2026 2:54:54 PM
K:\Public-Collected Civil\02_Projects\24001-24999\24020 - Wyelea Residential\24020.04 - Equestrian Center\02_DWG\C0.00_COVER.dwg
This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Collected Civil Engineering, LLC. shall be without liability to Collected Civil Engineering, LLC.
Tennessee811
KNOW WHAT'S BELOW.
CALL BEFORE YOU DIG
921B Woodland Street Nashville, TN 37206
COLLECTED
CIVIL ENGINEERING
DATE: PROJECT NUMBER:
24020.04
DRAWN BY:REVIEWED BY:
PR
SCALE:
ISSUED FOR:
NORTH ARROW:
PM
LAND DISTURBANCE PERMIT
NO:DATE:DESCRIPTION:
REVISIONS
1
7/1/26
7/20/26 RESPONSE TO REGULATORY COMMENTS
7/20/26
LOCATION MAP
1"=5000'
PROJECT DESCRIPTION
THE CONSTRUCTION OF THE THE STABLES OF THE WYELEA FARMS DEVELOPMENT
INCLUDING A CLUB HOUSE, STABLES, SHEDS, WAREHOUSE, MAINTENANCE BUILDING,
INDOOR ARENA, AND SURFACE PARKING. THE SCOPE OF WORK INCLUDES GRADING,
DRAINAGE, PAVING/HARDSCAPE, AND ALL ASSOCIATED UTILITY CONNECTIONS FOR THE
PROPOSED BUILDINGS.
SURVEY
BASE MAP INFORMATION TAKEN FROM A TOPOGRAPHIC, UTILITY AND BOUNDARY SURVEY
PREPARED BY WILSON & ASSOCIATES, P.C. DATED 6/23/23. COLLECTED CIVIL
ENGINEERING, LLC AND ANY OF THEIR CONSULTANTS ASSUMES NO RESPONSIBILITY OR
LIABILITY FOR ANY ERRORS OR OMISSIONS RESULTING FROM THE AFOREMENTIONED
SURVEY.
NPDES GENERAL PERMIT TNR100000 COMPLIANCE NOTES:
1. THE WYELEA FARMS - THE STABLES PROJECT AREA IS INCLUDED IN THE ISSUED
CONSTRUCTION GENERAL PERMIT (CGP) FOR THE OVERALL DEVELOPMENT
INFRASTRUCTURE WORK (TNR247592, EFFECTIVE 07/30/2024, EXPIRES 09/30/2026).
2. THE TOTAL AREA OF DISTURBANCE PLANNED FOR THIS PORTION OF THE PROJECT IS
53.702 ACRES.
3. ONCE STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITIES HAVE BEEN
ELIMINATED AND THE PERMITTED AREA ACHIEVES A UNIFORM 70% PERMANENT
VEGETATIVE COVER, OR HAS EQUIVALENT MEASURES (RIPRAP, GEOTEXTILE, ETC.), IN
AREAS NOT COVERED WITH IMPERVIOUS SURFACES, THE NOT (NOTICE OF
TERMINATION) CAN BE SUBMITTED TO TDEC FOR TERMINATION OF COVERAGE AND
TEMPORARY EROSION & SEDIMENT CONTROLS CAN BE REMOVED. ELIMINATION OF
STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY MEANS ALL
DISTURBED SOILS HAVE BEEN FULLY STABILIZED, THE TEMPORARY EROSION &
SEDIMENT CONTROLS HAVE BEEN REMOVED, AND/OR SUBSEQUENT OPERATORS
HAVE OBTAINED PERMIT COVERAGE.
4. SITE DISTURBING 1 ACRE OR LARGER SHALL HAVE TWICE WEEKLY INSPECTIONS BY A
TDEC LEVEL I CERTIFIED PERSON.
5. PLEASE REVIEW THE NPDES GENERAL PERMIT FOR RULES AND REGULATIONS
REGARDING CONSTRUCTION ACTIVITY.
PROJECT NOTES:
1. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL
STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS AS DESCRIBED IN SECTION 4
OF THE WILLIAMSON COUNTY STORMWATER MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS
SHOWN.
3. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING, GRADING,
CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON
COUNTY ENGINEERING DEPARTMENT.
4. ALL ROADWAYS WITHIN THE DEVELOPMENT WILL BE PRIVATE.
5. THE DEVELOPER HAS UTILIZED REASONABLE MEANS TO NOTIFY THE OPERATOR OF THE NATURAL GAS
TRANSMISSION PIPELINE TO VERIFY THE LOCATION OF THE PIPELINE AND THE PIPELINE EASEMENT. THE
DEVELOPER HAS REVIEWED, OR ATTEMPTED TO REVIEW, PRELIMINARY INFORMATION ABOUT THE
PROPOSED DEVELOPMENT WITH THE PIPELINE OPERATOR.
6. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS AND RIDGETOPS,
SLIPPAGE SOILS, AND KARST FEATURES. NONE OF THE MENTIONED FEATURES ARE PRESENT ON THIS
SITE.
7. THE PROPOSED DEVELOPMENT WILL COMPLY WITH ALL REQUIREMENTS AND LIMITATIONS OF
WILLIAMSON COUNTY ZONING ORDINANCE SECTION 16.02 (NOISE STANDARDS).
SITE DATA TABLE
ZONING: RURAL PRESERVATION (RP-5)
MAP & PARCEL NUMBER: 051-01300
BOOK & PAGE NUMBERS:8799 / 670-676
TOTAL SITE ACREAGE: 580.45 Ac.
THE STABLES (SECTION 1 PLAT O.S.3) ACREAGE: 53.702 Ac.
PROPOSED USE (COUNTRY CLUB)
CLUBHOUSE:2,476 SF
STABLES (2 BLDGS W/ 24 STALLS EACH):20,657 SF
MAINTENANCE & HAY STORAGE:2,502 SF
INDOOR ARENA:22,000 SF
OUTDOOR ARENA:45,294 SF
SETBACKS (COUNTRY CLUB)
1. 100 FEET FROM THE RIGHT-OF-WAY OF EXISTING ROADS
2. 200 FEET FROM PROPERTY LINES OF SURROUNDING PARCELS
3. 300 FEET FROM EXISTING RESIDENTIAL DWELLINGS ON SURROUNDING PARCELS
4. WHEN THE COUNTRY CLUB IS PART OF A RESIDENTIAL DEVELOPMENT, THE SETBACK
REQUIREMENTS IN 2 AND 3 ABOVE DO NOT APPLY TO PARCELS WITHIN THE
DEVELOPMENT.
UTILITY-POTABLE WATER
CITY OF FRANKLIN, TN
WATER MANAGMENT DEPT.
124 LUMBER DRIVE
FRANKLIN, TN. 37064
P: (615) 794-4554
UTILITY-NATURAL GAS
ATMOS ENERGY
200 NOAH DRIVE
FRANKLIN, TN. 37064
P: (615) 485-6377
UTILITY-ELECTRIC
MIDDLE TENNESSEE ELECTRIC
2156 EDWARD CURD LANE
FRANKLIN, TN. 37067
P: (615) 465-5602
FIRE PROTECTION
WILLIAMSON COUNTY STATION 14
405 DOWNS BLVD.
FRANKLIN, TN. 37064
P: (615) 790-5821
UTILITY-WASTEWATER
DESIGNER
ADENUS UTILITIES GROUP
849 AVIATION PARKWAY
SMYRNA, TN. 37167
P: (615) 220-7166
UTILITY-WASTEWATER
OPERATOR
TENNESSEE WASTEWATER
849 AVIATION PARKWAY
SMYRNA, TN. 37167
P: (615) 220-7200
ARCHITECT
PFEFFER TORODE ARCHITECTURE
SCOTT TORODE
921B WOODLAND STREET
NASHVILLE, TN 37206
P: (615) 667-0808
LAND SURVEYOR
WILSON & ASSOCIATES, P.C.
JOEY C. WILSON II, PE, RLS
CONTACT: SEAN MCGOWAN, PE
108 BEASLEY DRIVE
FRANKLIN, TN 37064
P: (615) 794-2275
PROJECT ENGINEER
COLLECTED CIVIL ENGINEERING
PETER ROMANO P.E.
921B WOODLAND STREET
NASHVILLE, TN 37206
PETER@COLLECTEDCIVIL.COM
P: (615) 917-0191
OWNER
WEST HARPETH PARTNERS, GP
40 BURTON HILLS BLVD, SUITE 200
NASHVILLE, TN. 37215
DEED BK 8799, PAGES 670-676
DEVELOPER
WYELEA DEVELOPMENT GROUP, LLC
TREVOR CROSS
40 BURTON HILLS BLVD, SUITE 200
NASHVILLE, TN 37215
P: (615) 496-4121
LANDSCAPE ARCHITECT
LANDDESIGN
ERIC POHLMANN, PLA, ASLA, LEED AP
223 NORTH GRAHAM STREET
CHARLOTTE, NC 28202
P: (704) 333-0325
FLOODPLAIN NOTE:
ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM FLOOD INSURANCE RATE
MAP (FIRM), WILLIAMSON COUNTY, TENNESSEE, COMMUNITY PANEL NUMBER
#47187C0183H AND #47187C0184H DATED 12/20/2024, THIS PROJECT SITE CONTAINS
REGULATED FLOODWAY, ZONE AE AND ZONE X.
THE STABLES SITE IS CONTAINED WITHIN ZONE X, AREAS DETERMINED TO BE OUTSIDE
THE 500-YEAR FLOODPLAIN.
DETAILED DRAINAGE PLAN
C4.20 DRAINAGE PLAN - STRUCTURE TABLE
C9.00 SITE DETAILS
C9.10 STORM SEWER DETAILS
C9.11 STORM SEWER DETAILS
C9.20 EROSION CONTROL DETAILS
C9.30 UTILITY DETAILS
DETAILED UTILITY PLANC6.10
ATTACHMENT 15-1A
C3.00
SITE PLAN
© 2025 Collected Civil Engineering, LLC
All rights reserved. copy or reproduction of this drawing or
document, or any portion thereof, without the express
written permission of Collected Civil Engineering, LLC. is
prohibited. This drawing or document is not intended or
represented to be suitable for any purpose other than the
specific project, application and situation for which it was
intended. Any modification of this drawing or document, or
any use for any project, application or situation other than
that for which it was intended, will be at user's sole risk and
without liability to Collected Civil Engineering, LLC.
Except as provided by rule 0120-02-.08(5)(b) of the
Tennessee state board of architecture and engineering
examiners, any changes made to this drawing or document,
after final revision and sealing by the registrant are
prohibited by any person other than the profession
registrant, including but not limited to owners/clients,
contractors, subcontractors, other design professional or any
of their agents, employees or assigns.
DRAWING NAME:
DRAWING NUMBER:
WYELEA FARMS
THE STABLES
3021 DEL RIO PIKE
WILLIAMSON COUNTY, TN 37069
7/20/2026 2:55:22 PM
K:\Public-Collected Civil\02_Projects\24001-24999\24020 - Wyelea Residential\24020.04 - Equestrian Center\02_DWG\C3.00_SITE.dwg
This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Collected Civil Engineering, LLC. shall be without liability to Collected Civil Engineering, LLC.
Tennessee811
KNOW WHAT'S BELOW.
CALL BEFORE YOU DIG
921B Woodland Street Nashville, TN 37206
COLLECTED
CIVIL ENGINEERING
DATE: PROJECT NUMBER:
24020.04
DRAWN BY:REVIEWED BY:
PR
SCALE:
ISSUED FOR:
NORTH ARROW:
PM
LAND DISTURBANCE PERMIT
NO:DATE:DESCRIPTION:
REVISIONS
1
7/1/26
7/20/26 RESPONSE TO REGULATORY COMMENTS
7/20/26
1" = 70'
SITE NOTES:
USE TYPE & MAXIMUM OCCUPANCY:
CLUB / LODGE2,489 SF, 17 PERSONS
(CLUBHOUSE)
WAREHOUSE20,480 SF, 42 PERSONS
(STABLES)
TOTAL OCCUPANCY59 PERSONS & 7 EMPLOYEES
PARKING:
REQUIRED
OUTDOOR AMUSEMENT
(1.0 SPACE PER FOUR (4) PEOPLE AT MAXIMUM
OCCUPANCY + 1 SPACE PER 2 EMPLOYEES ON
LARGEST SHIFT)
MAX OCCUPANCY15 SPACES
EMPLOYEES4 SPACES
TOTAL REQUIRED19 SPACES
PROVIDED
STANDARD SPACES13 SPACES
ACCESSIBLE SPACES2 SPACES
EMPLOYEE PARKING4 SPACES
TOTAL PROVIDED19 SPACES
7
8
4
ATTACHMENT 15-1B
ATTACHMENT 15-2
Item 16—Page 1 of 1
Reviewer: AVH
Date: 8/13/2026
ITEM 16
SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND
DISPOSAL SYSTEM REVIEW FOR BR YNN SUBDIVISION , ON 108.12 ACRES
LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007).
Area 108.12 acres
Zoning Rural Development-5 (RD-5)
Water Nolensville/College Grove Utility District
Development Options Non-Traditional Wastewater Treatment and Disposal System
Chapter 1101 Status Rural
Map and Parcel 137---00400
File Number (5-2026-007)
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Item 17—Page 1 of 1
Reviewer: OCW
Date: 8/13/2026
ITEM 17
SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG
WRITER’S CABINS , ON 2.5 ACRES LOCATED OFF CLUB VIEW DRIVE IN THE
5TH VOTING DISTRICT (5-2026-006).
Area 2.5
Zoning Rural Preservation – 1 (RP-1)
Water Milcrofton Utility District
Sewer Nontraditional Wastewater Treatment and Disposal System
Development Options PRCD
Chapter 1101 Status Rural
File Number (5-2026-006)
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Item 18—Page 1 of 1
Reviewer: JYJ
Date: 8/13/2026
ITEM 18
CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON
108.16 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (1 -
2026-203).
Area 108.16 acres
Lots 21
Zoning Rural Development-5 (RD-5)
Water Nolensville/College Grove Utility District
Sewer Non-Traditional Wastewater Treatment and Disposal System
Development Options Major Conservation Subdivision
Chapter 1101 Status Rural
Map and Parcel 137---00400
File Number (1-2026-203)
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Item 19—Page 1 of 1
Reviewer: AVH
Date: 8/13/2026
ITEM 19
CONCEPT PLAN REVIEW FOR 1600 RIVER LANDING D RIVE SUBDIVISION,
CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING DRIVE
IN THE 9TH VOTING DISTRICT (1-2026-204).
Area 22.76 acres
Lots Two (2)
Zoning Rural Preservation-5 (RP-5)
Water City of Franklin
Sewer Berry’s Chapel Utility, Inc.
Development Options Major Traditional Subdivision
Chapter 1101 Status Rural
Map and Parcel 038---01302
File Number (1-2026-204)
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Item 20—Page 1 of 3
Reviewer: JYJ
Date: 8/13/2026
ITEM 20
PRELIMINARY PLAT REVIEW FOR THE VILLAGES AT TRIUNE W EST
SUBDIVISION (REVISED), CONTAINING 98 SINGLE FAMILY LOTS, 214
TOWNHOME LOTS, AND T EN (10) NON-RESIDENTIAL LOTS ON 157.79 ACRES
LOCATED OFF HORTON HIGHWAY IN THE 5TH VOTING DISTRICT (1 -2026-
309).
Attachments 20-1 Preliminary Plat
20-2 Aerial Photograph
20-3 Applicant’s Request for Revised Concept Plan Conditions
20-4 Revised Review Memo from County’s Traffic Consultant
20-5 Original Review Memo from County’s Traffic Consultant
Area 157.79 acres
Zoning Triune Character Area -2 (TCA-2)
Triune Character Area -3 (TCA-3)
Triune Character Area -4 (TCA-4)
Lots 98 Single-Family Lots
214 Townhome Lots
Ten (10) Non-Residential Lots
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Options Conservation Subdivision, Multi-Family and Non-Residential
Chapter 1101 Status Triune Planned Growth Area (TPGA)
Map and Parcel 113--- 069.00 and 070.00
114--- 018.00, 020.00, 021.00, 022.00 and 022.01
File Number (1-2026-309)
A Revised Concept Plan for this developme nt was approved at the June 2026 meeting,
which added ten (10) non -residential lot s to the overall development. The currently
approved Preliminary Plat depicts only the residential component of the development.
The applicant is now requesting approval of a revised Preliminary Plat in order to
incorporate both the residential and non-residential components of the development into
a single Preliminary Plat. The revised Preliminary Plat is consistent with that depicted on
the revised Concept Plan.
During Concept Plan review, a Traffic Impact Analysis was perform ed by the applicant
and reviewed by the County’s Traffic Consultant. Numerous roadway improvements were
required in association with the development, and the construction of these
improvements is currently underway.
Item 20—Page 2 of 3
Reviewer: JYJ
Date: 8/13/2026
As a condition of approval , the applic ant is required to install a traffic signal at the
intersection of Horton Highway and Malachi Lane before the submittal of the Final Plat
containing the 25 th lot. At this time, the applicant is requesting modification of this
condition to allow the submittal of a Final Plat containing up to the 54th lot in Triune West
(this Item) and up to the 30th lot in Triune East, which appears as Item 21 on this agenda,
for a total of up to eighty-four ( 84) lots. The applicant has submitted a memo
documenting this request (See Attachment 20 -3), and this memo has been reviewed by
the County’s Traffic Consultant (See Attachment 20 -4). The County’s Traffic Consultant
has noted allowing the applicant to submit Final Plats for the eight y-four (84) lots prior
to construction of the signal at Horton Highway and Mal achi Lane will not result in a
significant traffic impact to the surrounding roadway network. Therefore, the County’s
Traffic Consultant has recommended the modification of the condition to allow the
submission of a Final Plat containing up to the 54th lot in Triune West, and that the
residential lots shall not be permitted to take access to Malachi Lane until the traffic signal
at the intersection of Horton Highway and Mal achi L ane has been installed and is
operational.
Staff recommends approval of the revised Preliminary Plat with the following conditions,
which shall be addressed in conjunction with Final Plat consideration:
1. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 55th lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4
and 20-5) shall be completed to the satisfaction of the Tennessee Department
of Transportation;
2. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 55th lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachmen ts 20-4
and 20 -5) shall be completed to the satisfaction of the Williamson County
Highway Superintendent;
3. As specified by the County’s Traffic Consultant, the i nstallation of traffic signals
and construction of the right turn deceleration lanes on Horton Highway at the I-
840 Eastbound and Westbound Ramps shall be completed/constructed prior to
the issuance of building permits for any of the non -residential land uses;
4. The residential lots shall not be permitted to take access to Malachi Lane until the
traffic signal at the intersection of Horton Highway and Malachi Lane has been
installed and is operational;
5. Prior to the submittal of the first Final Plat , the required Zoning Certificate for
the wastewater treatment and disposal system shall be submitted , a nd all
conditions associated with the wastewater site plan approval must be satisfied ;
Item 20—Page 3 of 3
Reviewer: JYJ
Date: 8/13/2026
6. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must address the greenway easement, the maintenance and
operation of t he private roads and gate that meet the standards , and
requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents
must be submitted with the Final Plat, and the approved HO A documents must
be recorded concurrently with the recording of the Final Plat;
7. A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning
Ordinance must be met;
8. Prior to the submittal of any Final Plat in which a greenway is located, the 12 -
foot-wide paved multi-modal greenway trail should be constructed;
9. Establishment of a performance bond for roads, drainage and erosion control;
10. Establishment of a perfo rmance bond for water improvements in favor of
Nolensville/College Grove Utility District;
11. Establishment of a performance bond for the wastewater collection system;
12. Submission of landscaping plans and establishment of a performance bond for
landscaping improvements;
13. Execution of Performance Agreements for the above -referenced sureties;
14. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
15. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and
recording of the plat.
86
88 87
8990919293949596
97
1
2
3
4
5
6
7
8
9
10
11
12
13
59
60
58
57
56
55
54
15
14
18
16
17
19
20
25
24
23
21
22
2726
30
28
29
3433
31
32
37
35
36
38 39 40 41
51
50
49
48
47
46
45
44 43 42
61
63
62
64
65
66
67
68
69
70
71
72
73
85
83
84
82
81
80
79
78
77
76
75
74
52
53
86
88 87
8990919293949596
97
1
2
3
4
5
6
7
8
9
10
11
12
13
59
60
58
57
56
55
54
15
14
18
16
17
19
20
25
24
23
21
22
2726
30
28
29
3433
31
32
37
35
36
38 39 40 41
51
50
49
48
47
46
45
44 43 42
61
63
62
64
65
66
67
68
69
70
71
72
73
85
83
84
82
81
80
79
78
77
76
75
74
52
53
HENRY HORTON HIGHWAY
OS
121
120
122
123
124
125
126
127
128
129 130 131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
108
109 110 111 112 113 114
115
116 117 118
119
99 100 101 102 103 104 105 106
224
225
226
227
228
229
223
222
221
220
219
218
154
153
155
156
157
152
151
150
149
158
159
160
107
0+00
0+00
0+37
0+64
0+61
0+64
POND C
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
(PRIVATE ALLEY)
TCA3
TCA2
TCA3TCA4
TCA2TCA4
TCA2TCA4
OS
OS
OS
OS
75-FT WATERWAY
NATURAL AREA
(WNA)
WETLAND WITH
30-FT WATER
NATURAL AREA
(WTL-3)
WETLAND WITH
50-FT WATER
NATURAL AREA
(WTL-4)
WETLAND WITH
50-FT WATER
NATURAL AREA
(WTL-5)
WET WEATHER CONVEYANCE (WWC-1/EPH-1)
WILSON BRANCH
PERENNIAL STREAM
WITH 75-FT WATER
NATURAL AREA
(STR-1)
50-FT WATERWAY
NATURAL AREA
(WNA)
INTERMITTENT
STREAM WITH
50-FT WATER
NATURAL AREA
(STR-2)
WET WEATHER CONVEYANCE
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA GREATER
THAN 5 ACRES
(WWC-4)
25 FT DRAINAGE
EASEMENT
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA GREATER
THAN 5 ACRES
(WWC-5)
25 FT DRAINAGE
EASEMENT
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA GREATER
THAN 5 ACRES
(WWC-3)
25 FT DRAINAGE
EASEMENT
WETLAND WITH
50-FT WATER
NATURAL AREA
(WTL-6)
75-FT WATERWAY
NATURAL AREA
(WNA)
WET WEATHER CONVEYANCE
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA LESS
THAN 5 ACRES
(WWC-2/UDF-1)
25 FT DRAINAGE
EASEMENT
WET WEATHER CONVEYANCE
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA GREATER
THAN 5 ACRES
(WWC-3)
25 FT DRAINAGE
EASEMENT
POND A
POND B
178 181180179178177
206
207
208
209
210
204
203
202
201
192
193194195
191190189188187
200
199
198
197
196
186
185
184
183
182
175174173172
169
211
212
213
214
215
216
217
176
171
168167166165164163162
231232 233234 237 238 239240 241
230
251
250
249
248
247
246
258
257
256
255
254
253
252
266
265
264
263
262
261
285
283
282
281
280
279
278
277
276
275
274
273
272
271
270
293
292
291
290
289
288
287
286
298
297
296
295
294
301302
303
308
310311
312
307 306
305
260
259
235
309
304
269
268267
243244245
242
18'X28'USE /MAINTENANCE
EASEMENT TYPICAL
18'X28'USE /MAINTENANCE
EASEMENT TYPICAL
284
18'X28'USE /MAINTENANCE
EASEMENT TYPICAL
18'X28'
USE /MAINTENANCEEASEMENT TYPICAL
18'X28'
USE /MAINTENANCEEASEMENT TYPICAL
18'X28'
USE /MAINTENANCE
EASEMENT TYPICAL
18'X28'
USE /MAINTENANCE
EASEMENT TYPICAL
18'X28'
USE /MAINTENANCEEASEMENT TYPICAL
18'X28'
USE /MAINTENANCEEASEMENT TYPICAL
236
40' ROW ROAD (PRIVATE DRIVE)
40' ROW ROAD (PRIVATE DRIVE)
PRIVATE ALLEYPRIVATE ALLEY
75 FT
98
98
161
170
205
PRIVATE ALLEY
300299
40' ROW ROAD (PRIVATE DRIVE)
40' ROW ROAD (PRIVATE DRIVE)
40' ROW ROAD (PRIVATE DRIVE)
PRIVATE ALLEY
PRIVATE ALLEYPRIVATE ALLEY
PRIVATE ALLEY
PRIVATE ALLEY
POND F
50 FT
15' LDSB
50' OS BUFFER
LOT 321LOT 321
OS-6
LOT 316
OS-9
LOT 313
LOT 314
OS-8
OS-7
LOT 320
LOT 318
LOT 319
OS-5
LOT 315
LOT 317
OS-4
50' OSB
15' LDSB
15' LDSB
15' LDSB
15' LDSB
15' LDSB
LOT 322
50' OSB
50' OSB
50' OSB
15' LDSB
15' LDSB
15' LDSB
50' OSB
50' OSB
15' LDSB
15' LDSB
50' OSB
50' OSB
50' OSB
OS-4
SCALE: 1"=200'
SURVEY DIVISION
214 Centerview Drive Suite 300
Brentwood, TN 37027
615.370.8500
615.370.8530
woldae.com
Contact
John Powell
Ashby Communities, LLC.
P.O. Box 190 Arrington, TN 37014
(615) 496-8681
SITE ADDRESS:
8039 HORTON HWY
Arrington, TN 37014
RESOURCE PROTECTION NOTE:
THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 AND
ARTICLE 19: FLOOD HAZARD REDUCTION AND COMPLIANCE WITH THE
NATIONAL FLOOD INSURANCE PROGRAM OF THE ZONING ORDINANCE FOR
RESOURCE PROTECTION. THE RESOURCES INCLUDE, BUT ARE NOT LIMITED TO:
STEEP SLOPE PROTECTION, WOODLAND AND TREE PROTECTION, WETLAND
PROTECTION & MITIGATION, AND WATERWAY PROTECTION. THE RESOURCES
NOT FOUND ON THE SITE ARE: KARST TOPOGRAPHY AND HISTORIC &
CULTURAL RESOURCES
CRITIAL LOT NOTE:
*
PROPOSED SINGLE FAMILY LOTS THAT HAVE EXISTING CRITICAL SLOPES
ARE INDICATED WITH THIS SYMBOL (*). AN ENGINEERED SITE PLAN SHALL
BE SUBMITTED AND APPROVED BY WILLIAMSON COUNTY ENGINEERING
DEPARTMENT.
ALL LOTS CURRENTLY CONTAIN CRITICAL SLOPES WITH EXISTING
TOPOGRAPHY.
ALL VERY STEEP SLOPES ARE CONTAINED WITHIN OPEN SPACE AREAS.
06
91
.SSE
ET
NN
NEE O
ATTACHMENT 20-1
ATTACHMENT 20-2
July 20, 2026
Mr. Aaron Holmes, AICP - Planning Director
Williamson County Planning Commission
1320 West Main Street Suite 400
Franklin, TN 37064
Re: Villages at Triune West & East – Request for Revised Concept Plan Conditions
Williamson County, Tennessee
Dear Mr. Holmes,
We respectfully request that Williamson County allow for the submittal and approval of a phased final
plat for the residential lots within the development to be served exclusively by the approved site driveway
connections to Murfreesboro Road (S.R. 96) for both the Villages at Triune West and Villages at Triune
East developments. This request is based on the Traffic Impact Study (TIS) prepared by Civil &
Environmental Consultants, Inc. (CEC), revised February 2025, and is supported by updated intersection
capacity analysis (CEC, July 2026) demonstrating that the proposed plats operate within the traffic
volumes and levels of service those intersections were designed and analyzed to accommodate.
The current conditions of approval associated with the development require that all of the offsite roadway
improvements be installed and approved by TDOT prior to being able to submit for a Final Plat for more
than 24 residential units from either the Villages at Triune West or East subdivisions. This is based on the
assumption that the existing intersection of Horton Highway and Malachi Lane restricts what traffic can be
discharged at that intersection under current unsignalized conditions.
The developer is preparing to submit the first final plats for both the West and East sides in time to
appear on the October 2026 Planning Commission meeting agenda. The proposed first final plats are as
follows:
• Villages at Triune West — First Final Plat: 54 residential units (mix of single-family and
townhomes), to be submitted in advance of the October 2026 Planning Commission meeting.
• Villages at Triune East — First Final Plat: 30 residential units (mix of single-family and
townhomes), submitted on the same schedule for the October 2026 Planning Commission meeting.
The timing of this request is driven by the construction schedule of the signalized intersection at Horton
Highway and Malachi Lane, which is not anticipated to be complete and open to traffic until December
2026 — after the targeted October Planning Commission approval of these first final plats. As detailed in
the following sections, the traffic analysis in this letter accounts for that interim condition and confirms that
the S.R. 96 intersections can accommodate the proposed plats within the volumes already studied and
approved. Additionally, if allowed and approved by the Planning Commission at the October 2026
meeting, the recording of the Final Plat and then construction of the homes within the plat can begin. It is
anticipated that the homes from the first plat would not be fully constructed until well into 2027, with the
traffic signal fully installed and operating.
CURRENT CONDITIONS OF APPROVAL — RESIDENTIAL
The Triune development received approval for the following residential program, as analyzed at full
build-out in the CEC TIS:
ATTACHMENT 20-3
Table 1 — Approved Residential Program
Development Area Single-Family Townhomes Total Units
Triune West 99 213 312
Triune East 58 64 122
Total 157 277 434
With respect to platting and access, the existing condition of approval limits residential development to a
combined total of 24 residential lots across both the East and West sides prior to installation of the
signalized intersection at Horton Highway (U.S. 31A/41A/S.R. 11) and Malachi Lane (the “Malachi Lane
Signal”). This interim limit reflects the TIS assumption that the Malachi Lane Signal would be operational to
serve as the principal access for Triune East and a significant secondary access for Triune West at the time
residential occupancy commenced.
BASIS FOR THIS REQUEST — INTERIM ACCESS DURING CONSTRUCTION
The approved development includes a second primary access connection via the Malachi Lane Signal,
which the TIS analyzed as the principal point of access for the Triune East site and a significant secondary
access for Triune West. Construction of that signalized intersection is about to begin; however, it is not
anticipated to be open to traffic until December 2026.
During the interim period prior to the Malachi Lane Signal opening, the S.R. 96 site driveways will serve as
the sole access connection for residential traffic on both the West and East sides of the development.
Under this scenario, 100% of the vehicle trips generated by the platted residential units will be routed
through the S.R. 96 intersections.
The 24-lot interim limit would unduly constrain the initial development phase during the intervening period
despite the availability of adequate capacity at the S.R. 96 site driveways, which were designed and
analyzed to accommodate substantially higher volumes at full build-out. As demonstrated by the updated
capacity analysis below, the requested 54 (West) and 30 (East) units can be accommodated at the S.R. 96
driveways during the interim period at acceptable levels of service. Once the Malachi Lane Signal is open,
residential trips will distribute across all approved access points per the TIS distribution percentages,
materially reducing the S.R. 96 share and permitting the platting of any remaining residential units without
further constraint.
TRIP GENERATION — REQUESTED UNITS
Trip generation for the requested first final plats was prepared by CEC using ITE Trip Generation, 12th
Edition (average rates), for Land Use Code 210 (Single-Family Detached Housing) and Land Use Code
215 (Single-Family Attached Housing / Townhomes). The results, which serve as the basis for the interim
capacity analysis, are summarized below.
Table 2 — Triune West First Final Plat (54 Units): Trip Generation
Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total)
Single-Family (210) 15 148 3 / 2 / 17 9 / 5 / 14
Townhome (215) 39 276 5 / 13 / 18 11 / 9 / 20
West Total 54 424 8 / 21 / 29 20 / 14 / 34
Table 3 — Triune East First Final Plat (30 Units): Trip Generation
Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total)
Single-Family (210) 8 89 2 / 4 / 6 5 / 2 / 7
Townhome (215) 22 155 3 / 7 / 10 6 / 5 / 11
East Total 30 244 5 / 11 / 16 11 / 7 / 18
No internal capture or pass-by reductions were applied to the residential trip generation, consistent with
the TIS treatment of the residential land uses. During the interim phase, 100% of these trips are assigned
to the respective S.R. 96 site driveways, as reflected in the CEC analysis.
INTERIM TRIP DISTRIBUTION
During the interim phase, because no access is provided at Malachi Lane, 100% of the trips generated by
the requested residential units are assigned to the respective S.R. 96 site driveways. These trips will follow
the trip distribution from the original TIS and a figure has been provided in the attachments showing the
percentage of trips assigned.
The Triune West driveway lies approximately 1,600 feet west of the Horton Highway / S.R. 96
intersection, and the Triune East driveway approximately 2,300 feet east of it. The intersection therefore
lies between the two driveways. Only West site trips traveling east, and East site trips traveling west,
traverse the Horton Highway / S.R. 96 intersection — approximately 21 A.M. and 25 P.M. peak-hour site
trips, or roughly 1% of the existing intersection volume. This distribution is reflected in the 2026 Build
turning-movement volumes used in the capacity analysis below.
INTERIM CAPACITY ANALYSIS — 2026 BUILD CONDITIONS
At the County's request, CEC performed a peak-hour capacity analysis of the three study intersections that
serve or are traversed by interim site traffic, using the Highway Capacity Manual, 7th Edition
methodology in Synchro Version 12, consistent with the TIS. The interim (2026 Build) volumes were
developed by adding the site trip generation above — assigned 100% via the S.R. 96 driveways per the
interim access condition — to the 2026 No-Build turning-movement volumes from the TIS. The analysis
reflects the committed turn-lane improvements at each S.R. 96 driveway that are currently under
construction and will be finished by the time the first final plat will be submitted. Results for the weekday
A.M. and P.M. peak hours are presented below.
S.R. 96 Site Driveways (Unsignalized, Two-Way Stop Control)
Both S.R. 96 site driveways operate at an overall intersection delay of less than one second per vehicle
(LOS A) in both peak hours. The stop-controlled northbound site-exit approaches operate at acceptable
levels of service with negligible queuing (95th-percentile queues of less than one vehicle). The
Murfreesboro Road left-turn movements entering the driveways operate at LOS A–B.
Table 4 — 2026 Build LOS & Delay: S.R. 96 Site Driveways
Intersection / Movement AM LOS
(Delay)
AM
95% Q
PM LOS (Delay) PM
95% Q
West Dwy — WB Left (into dwy) A (8.1) 0 B (10.8) 0.1
West Dwy — NB Left (exit) E (36.0) 0.1 E (35.2) 0.1
West Dwy — NB Right (exit) B (10.5) 0.1 C (19.2) 0.1
West Dwy — NB approach C (15.4) — C (22.7) —
Intersection / Movement AM LOS
(Delay)
AM
95% Q
PM LOS (Delay) PM
95% Q
West Dwy — Overall A (0.3) — A (0.3) —
East Dwy — WB Left (into dwy) A (7.5) 0 A (8.8) 0
East Dwy — NB approach (exit) B (14.6) 0.1 C (16.4) 0.1
East Dwy — Overall A (0.2) — A (0.2) —
The northbound left-turn movement at the West driveway reflects LOS E; this is typical of a low-volume
minor-street left turn crossing a higher-volume arterial under stop control and involves only a handful of
vehicles per hour (a 95th-percentile queue of less than one vehicle). It does not affect the overall driveway
operation, which remains LOS A.
Horton Highway / S.R. 96 (Signalized)
The Horton Highway / S.R. 96 signalized intersection was analyzed under both the 2026 No-Build and
2026 Build (with 84 interim units) conditions. The results demonstrate that the interim plats do not degrade
the overall operation of this intersection relative to the No-Build condition. In the A.M. peak hour, the
overall intersection delay under the Build condition is essentially unchanged from — in fact marginally
better than — the No-Build condition. In the P.M. peak hour, the overall level of service remains within one
grade of the No-Build condition.
Table 5 — Horton Hwy / S.R. 96: 2026 No-Build vs. 2026 Build (84 Units)
Approach AM No-Build AM Build PM No-Build PM Build
Murfreesboro Rd — Eastbound D (37.0) C (30.5) C (30.9) D (39.6)
Murfreesboro Rd — Westbound F (92.5) F (93.9) C (28.3) C (26.3)
Horton Hwy — Northbound E (65.7) E (56.9) C (27.1) C (30.0)
Nolensville Rd — Southbound F (111.2) F (117.9) D (37.1) D (48.8)
Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8)
The westbound and southbound approaches reflect LOS F in the A.M. peak hour under both the No-Build
and Build conditions. This is a pre-existing regional congestion condition at this intersection that is present
with or without the interim plats; the addition of the 84 interim units does not change the overall A.M. level
of service (LOS E in both cases) and in fact slightly reduces overall delay. As documented in the TIS,
improvements at this intersection are tied to regional conditions and the broader Horton Highway corridor
rather than to this residential phase.
DISCUSSION OF INTERIM IMPACTS
The updated CEC capacity analysis confirms that the requested interim plats can be accommodated during
the period prior to installation of the Malachi Lane Signal without adverse operational impact at the study
intersections:
• S.R. 96 site driveways: Both driveways operate at overall LOS A in both peak hours, with 95th-
percentile queues of less than one vehicle on the stop-controlled site-exit approaches. The
committed turn-lane improvements accommodate entering and exiting movements without
impeding S.R. 96 through-traffic. The interim volumes (29 West / 16 East in the A.M.; 34 West /
18 East in the P.M.) represent less than 3% of the existing S.R. 96 mainline traffic at each location.
• Horton Highway / S.R. 96 signalized intersection: Only approximately 21 A.M. and 25 P.M.
site trips traverse this intersection — roughly 1% of its total entering volume. The analysis confirms
the interim plats do not degrade the overall level of service: the A.M. peak remains LOS E (with
slightly lower overall delay than No-Build), and the P.M. peak remains within one grade of No-
Build. The LOS F approaches present in the A.M. peak are pre-existing regional conditions
independent of this residential phase.
• Relationship to the analyzed full build-out: The TIS analyzed each of these intersections under
the full build-out condition — the entire 434-unit residential program plus all commercial land uses
— and identified the improvements necessary to maintain acceptable operations. The interim
phase places only a small fraction of that analyzed volume on the network, entirely via the S.R. 96
driveways, and therefore operates well within the previously accepted envelope.
CONCLUSION
This letter documents the current residential conditions of approval, the specific interim plat modification
requested (54 units West / 30 units East, all single-family and townhome product), the interim access
configuration in which all site access is provided exclusively via the S.R. 96 driveways with no Malachi Lane
access until the signal is complete, the trip generation for the requested units, and the updated CEC
capacity analysis of the three study intersections. That analysis confirms that the S.R. 96 site driveways
operate at overall LOS A, and that the Horton Highway / S.R. 96 signalized intersection is not degraded
by the interim plats relative to the 2026 No-Build condition.
All required roadway improvements at each S.R. 96 driveway are committed conditions of development
approval. Upon completion and opening of the Malachi Lane / Horton Highway signalized intersection —
anticipated December 2026 — residential trips will distribute across all approved access points consistent
with the TIS, and the developer will plat all remaining units in accordance with the full build distribution
model.
We respectfully request that the Planning Commission revise the approved conditions to allow for the
phased final plat approach described herein and are available to meet or provide any additional
information at your convenience.
Sincerely,
Will Crunk, PE
Crunk Engineering LLC
1 | P a g e
MEMORANDUM
To: Aaron Holmes, Williamson County Planning Department
From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC
Date: 8/5/26
Subject: Triune Mixed-Use – Requested Conditions of Approval Revisions
Introduction
The Triune Mixed -Use development includes a combination of residential and commercial
components located at the intersection of Horton Highway (US 41/SR 11) and Murfreesboro Road
(SR 96) in unincorporated Williamson County. Following submittal and review of a Traffic Impact
Study (TIS) according to the County’s guidelines, the development was approved with conditions,
and construction of the first development phase, which includes all residential components split
on the east and west sides of Horton Highway, began in 2026.
The conditions of approval placed on the development included multiple requirements specific to
off-site transportation improvements and their timing relative to preliminary and final plat
submittals. As residential lots continue to be submitted for preliminary and final plats, the off-site
improvements recommended in the February 2025 TIS are being constructed as required.
One specific condition of approval included construction of a traffic signal at the intersection of
Horton Highway and Malachi Lane, which will serve as a primary access to both Triune East and
West at full buildout. This signal was required to be constructed and operational before the 25 th
residential lot was submitted for final plat based on the existing and projected traffic volumes at
this intersection. According to the developer’s engineer, Crunk Engineering, construction of this
signal has been delayed but is still on track to be completed by the end of 2026 , which the
development team claims will be well in advance of any residential units being completed .
Therefore, the applicant is requesting a change to the existing conditions of approval in order to
adhere to their desired development timeline. More specifically, the applicant is requesting that
they be allowed to submit final plats for 84 residential units (60 more than is currently allowed)
prior to the traffic signal being constructed. The applicant has submitted a memo documenting
this request, including supplemental traffic operational analysis to evaluate the potential interim
condition in which 84 lots are constructed but access to Malachi Lane is not provided, routing all
development-generated traffic through the two site accesses on Murfreesboro Road and the
intersection of Horton Highway and Murfreesboro Road.
ATTACHMENT 20-4
2 | P a g e
Analysis Review
In order to evaluate the proposed interim access condition, a small-scale traffic impact analysis
was conducted with standard components – trip generation, trip distribution and assignment, and
capacity analysis – all described below.
• Trip Generation - The projected trip generation was calculated for both Triune East, which
includes a proposed 15 single family homes and 39 townhomes, and Triune West, which
includes a proposed 8 single family homes and 22 townhomes, for a combined 84
residential dwelling units. The trip generation calculations do not follow the latest version
of ITE’s Trip Generation Manual, 12th Edition, as stipulated in the memo, nor do they use
industry standard practice of using the fitted curve equations as appropriate; however,
with the relatively low number of dwelling units proposed, the discrepancy in trips
generated is unlikely to make a difference in the operational outcomes.
• Trip Distribution and Assignment – Under the interim access condition, all trips
generated by the additional 84 residential units would utilize the Triune East and Triune
West accesses on Murfreesboro Road. According to the 2025 TIS, trips generated by the
development were expected to be oriented as follows:
o 25% of trips to/from I-840 WB ramps
o 20% of trips to/from I-840 EB ramps
o 20% of trips to/from the west on Murfreesboro Road
o 15% of trips to/from the east on Murfreesboro Road
o 10% of trips to/from south on Horton Highway
o 10% of trips to/from north on Horton Highway/Nolensville Pike
With access limited to Murfreesboro Road, trips would redistribute at the two accesses
and at the signalized intersection of Horton Highway and Murfreesboro Road. The
following turning movements would see higher volumes during peak periods:
o Eastbound right turns on Murfreesboro Road at the Triune East access
o Westbound left turns on Murfreesboro Road at the Triune West access
o Northbound left and right turns on Horton Highway at the existing signal
o Eastbound right and westbound left turns on Murfreesboro Road at the existing
signal
It should be noted that the northbound and southbound through volumes on Horton
Highway at the existing Malachi Lane intersection will also increase with the redistribution
of traffic volumes generated by the 84 residential units . While not included in the
requested analysis, it can be anticipated that any additional through volume on the major
street will increase delays for the minor street volumes that exist today.
3 | P a g e
• Capacity Analysis – Capacity analysis was completed for both projected 2026 AM and PM
peak hours under the interim access scenario. The analyses account for the conditioned
off-site improvements at both Murfreesboro Road accesses as they will be complete prior
to construction of any residential units. The volumes, traffic control, and intersection
geometry utilized in the projected analyses are reasonably correct. Table 1 summarizes
the level of service (LOS) and vehicular delay projected at the three study intersections
under the 2026 background, or no-build, condition as well as the 2026 projected, or build,
condition during which access to Malachi Lane is not provided and all residential trips for
the proposed 84 residential units is routed through the Murfreesboro Road accesses.
The capacity analysis addressed the AM and PM peak hours at three intersections: the
existing signalized intersection of Horton Highway and Murfreesboro Road, and the two
unsignalized Murfreesboro Road driveways serving Triune East and Triune West. The no-
build condition reflects the intersection geometry, traffic control, and signal timing
documented in the February 2025 TIS, and the build condition adds the redistributed trips
from the interim access scenario described above. The two driveway intersection s are
shown only under the build condition, since they do not exist without the development.
One item in the capacity analysis should be noted. The signal timing at Horton Highway
and Murfreesboro Road was not held constant between the no-build and build scenarios;
the cycle length was shortened along with the retiming. In the AM peak hour, the overall
cycle length dropped from approximately 190 seconds under no-build to approximately
150 seconds under build, and in the PM peak hour it dropped from approximately 103
seconds to approximately 88 seconds, even though the traffic volumes at this intersection
are nearly identical between the two scena rios. Because the timing plan changed at the
same time as the volumes, the delay and LOS differences reported for this intersection
reflect the combined effect of both variables, and the operational impact of the additional
84 units cannot be isolated from the effect of the signal retiming. The shorter cycle s
improve LOS for movements with excess capacity but push already -saturated
movements, including the WB and SB through movements, further past capacity,
worsening their delay and queuing. The net effect is a slight improvement in the AM peak,
where the intersection was already failing, but a full LOS drop from C to D in the PM peak,
where it previously was not.
Setting aside the signal timing discrepancy at Horton Highway and Murfreesboro Road,
the additional volumes generated by the interim access scenario are expected to have a
limited effect on operations at the three study intersections. The two new driveways
operate at LOS C or better for nearly all movements, with the exception of the
northbound left turn at the Triune West driveway, which operates at LOS E in both peak
hours and is expected for an unsignalized minor street approach movement along an
4 | P a g e
arterial. The existing signalized intersection already operates at LOS E in the AM peak hour
and LOS C to D in the PM peak hour under the no -build condition, and the incremental
delay attributable to the added 84 units, apart from the timing changes discussed above,
is small relative to the background condition. Only one movement, the northbound left
turn, deteriorates in LOS between the no-build and build conditions during the PM peak
hour. Given that this condition is temporary and will be resolved once the Malachi Lane
signal is constructed, these results do not support a requirement for additional off -site
infrastructure improvements to accommodate the interim access scenario.
Table 1. Comparison of 2026 Background (No-Build) and Projected (Build) Peak Hour Operations
Intersection/Movement
LOS (Vehicular Delay in sec/veh)
AM
No-Build
AM
Build
PM
No-Build
PM
Build
Murfreesboro
Road and
Horton
Highway/
Nolensville
Pike
EB Left Turn E (76.0) E (58.0) C (23.3) C (21.5)
EB Through D (45.2) D (37.9) D (36.6) D (52.5)
EB Right Turn C (21.8) B (19.4) C (26.7) C (30.4)
WB Left Turn D (42.6) C (34.5) C (27.9) C (26.0)
WB Through F (98.6) F (101.9) C (28.4) C (26.5) WB Right Turn
NB Left Turn F (100.9) F (87.2) C (27.5) D (37.0)
NB Through C (31.7) C (27.6) C (26.9) C (25.9) NB Right Turn
SB Left Turn D (46.3) D (38.1) C (23.7) C (21.2)
SB Through F (113.7) F (120.9) D (38.9) D (52.5) SB Right Turn
Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8)
Murfreesboro
Road and
Triune East
Driveway
WB Left Turn -- A (7.5) -- A (8.8)
NB Left Turn -- B (14.6) -- C (16.4)
Murfreesboro
Road and
Triune West
Driveway
NB Left Turn -- E (36.0) -- E (35.2)
NB Right Turn -- B (10.5) -- C (19.2)
WB Left Turn -- A (8.1) -- B (10.8)
5 | P a g e
Conclusion
Based on the review of the supplemental traffic operational analysis, allowing the applicant to
submit final plats for up to 30 lots in Triune East and up to 54 lots in Triune West for a total of 84
residential units prior to construction of the Malachi Lane signal1 is not expected to result in a
significant traffic impact to the surrounding roadway network. The interim access scenario, which
routes all development-generated trips through the two Murfreesboro Road driveways and the
existing signalized intersection at Horton Highway, results in relatively minor incremental delays
at the existing signal beyond what is already occurring under background conditions. This
condition is temporary by design and will be resolved once access from Triune East and West is
provided via Malachi Lane. Therefore, the request to submit final plats for the 84 lots, up to 30
lots in Triune East and up to 54 lots in Triune West, is reasonable provided that the residential
lots within Triune East and Triune West are not permitted to access Malachi Lane or the traffic
signal is constructed, which the applicant's engineer indicates remains on track for completion
by the end of 2026, well ahead of any residential units being constructed. Accordingly, I do not
recommend requiring additional off-site infrastructure improvements as a condition of
approving the applicant's request, and I recommend that residential lots in either Triune East
or Triune West shall not be permitted to take access to Malachi Lane until the traffic
signal at the intersection of Horton Highway and Malachi Lane is installed and operational
in order to protect the County and existing traffic on Malachi Lane from added development
traffic in the interim.
Should you have any questions or need additional information, please contact me.
Sincerely,
Kayla Ferguson, PE, AICP
Burch Transportation, LLC
1 The existing condition of approval limits residential development to a combined total of 24 residential lots
across both Triune East and West prior to installation of the signal .
1 | Page
MEMORANDUM
To: Aaron Holmes, Williamson County Planning Department
From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC
Date: 3/3/2025
Subject: Triune Mixed-Use TIS Review
Thi
s memorandum provides the findings of the independent review of the Triune Mixed -Use TIS
submitted to Williamson County Planning on 2/20/2025 for a concept plan submittal. The review
focused on the following three items: consistency with assumptions discussed in the traffic study
scoping and included in the executed MOUA, review of the traffic operational analyses, and
evaluation of recommended infrastructure improvements. Based on this review, we identify any
necessary modifications to the traffic study and/or the recommendations that ensure consistency
with the County’s Traffic Study Guidelines and mitigate impacts of the proposed project.
G
eneral Project Information and Traffic Study Scope
The Triune Mixed-Use development proposal includes a new development plan located on either
side of Horton Highway (US 41A/SR 11) between Murfreesboro Road (SR 96) and I -840 in the
Triune area of Williamson County. The proposed development plan is referred to as Triune East
and Triune West based on its bifurcation via Horton Highwa y. The two sites will each include a
mix of residential unit types and commercial space and have six total accesses proposed – two on
Murfreesboro Road and four on Horton Highway. Based o n the proposed density and trip
generation of the development, a Traffic Impact Study was required. A traffic study scoping call
was conducted with the applicant’s traffic study preparer on August 21, 2024. The outcome of
this meeting was an agreed upon set of assumptions and study parameters for the traffic study.
Table 1 identifies key traffic study elements and an evaluation of their consistency with the agreed
upon scope. As noted, the traffic study submitted accurately reflects the current concept plan and
the scope as agreed upon in the MOUA.
ATTACHMENT 20-5
2 | Page
Table 1: Review of Traffic Study Scope Elements
Project
Characteristic Documented in Traffic Study Consistent with MOUA?
Proposed Land
Use and Density
342 single-family residential units
98 multifamily residential units
42,400 sf restaurant space
54,400 sf retail space
45,000 sf supermarket
16,000 sf hardware store
50,400 sf office space
318-room hotel
Ye s
No
Trip Generation AM: 1,184 total / 612 enter / 572 exit
PM: 1,777 total / 938 enter / 839 exit
Yes
No
Notes: Exact trip totals are
higher than presented in MOUA,
but calculations are appropriate
and correct.
Buildout and
Background
Growth
Buildout Horizon: 2026 / 2031
Annual Growth Rate: 1.0%
Site Specific Growth: Burns Property,
Troubadour, Kings Chapel, Hardeman Springs,
Fiddler’s Glen, and Patterson Road
Development
Ye s
No
Study Area
Segments: Murfreesboro Road; Horton Hwy
Intersections:
• Horton Highway / I-840 EB ramp
• Horton Highway / I-840 WB ramp
• Horton Highway / Murfreesboro Road
• Horton Highway and Malachi Lane/Site Access
• Horton Highway / Triune East Site Access
• Horton Highway / Triune West Site Access
• M
alachi Lane / Site Access
• M
urfreesboro Road / Triune West Site Access
• Murfreesboro Road / Triune East Site Access
Ye s
No
Notes: Additional site accesses
were included to reflect changes
in the site plan following the
MOUA execution.
T
raffic Operational Analyses
The operational analyses for the intersections and roadway segments within the study area were
based on methods from Highway Capacity Manual. The following bullets highlight a review of the
analysis as documented in the TIA:
• Data to support the traffic analyses was collected from 7:00-9:00 AM and 4:00-6:00 PM
on Thursday, September 5, 2024 when local schools were in session.
• Based on the data collected and capacity analysis, there are multiple critical turning
movements that operate at LOS E or worse during existing peak hour conditions. More
s
pecifically, minor street left turn movements on the I-840 eastbound and westbound
ramps as well as multiple movements at the signalized intersection of Murfreesboro
3 | Page
Road and Horton Highway/Nolensville Road all currently operate unacceptably during at
least one if not both peak hours.
• Background and projected capacity analysis is divided into two horizon years. The first
represents a 2026 buildout year, which is expected to include all of the proposed
residential density in the Triune East and Triune West developments. The second
represents a 2031 buildout year, which is expected to include all of the non-residential
density.
• Continued growth in the region as well as this specific area of the County add significant
peak hour volumes to the critical intersections over the 7-year buildout horizon. This
causes already-failing movements to further deteriorate with significant increases in
average vehicular delays during peak hours before construction of the Triune mixed-use
development. The most significant delay is predicted for vehicles turning left from the
stop-controlled I-840 eastbound ramp onto Horton Highway, averaging ~5 minutes per
vehicle in the AM peak hour and ~27 minutes per vehicle in the PM peak hour in 2031.
• Addition of the proposed Triune Mixed-Use project causes significant increases in delays
for aforementioned critical turning movements at existing intersections. Table 2
highlights the specific scenario in which critical turning movements are expected to
operate at LOS E (indicated with green shading) and the corresponding vehicular delay
expressed in seconds per vehicle. For the 2026 and 2031 projected scenarios, the
additional delay added by the proposed project is shown in parentheses.
• As shown in Table 2, the intersection of Horton Highway and Murfreesboro Road has
multiple movements that already operate at LOS E, but the relative increase of delay
caused by the Triune Mixed-Use development is low. For example, the proposed
development is expected to add a maximum of 36 seconds to any of these movements,
specifically the westbound through/right turn movement. It should be noted that TDOT
has plans to eventually widen the Murfreesboro Road in the vicinity of the Triune
Mixed-Use project. The widening of Murfreesboro Road will also include capacity
improvements at this intersection that will help to alleviate the existing and projected
delays. However, no funding is allocated for this project and the anticipated completion
is, therefore, unknown.
• By contrast, delays added to the unsignalized I-840 ramps with completion of the
proposed project are significant. Traffic signal warrant analyses were conducted to
determine if and when traffic volumes would justify the need for traffic signals at these
locations. According to methodology set forth in the MUTCD and the typical
requirement to satisfy an 8-hour volume warrant on State Routes like Horton Highway,
both of these ramp intersections warrant traffic signal control under existing conditions.
Further, the study notes that additional capacity will be needed along Horton Highway,
specifically right turn lanes onto the I-840 ramps, in addition to traffic signal control to
mitigate projected delays.
4 | Page
Table 2: Summary of Critical Existing Intersection Operations
Intersection Critical Movement Peak
Hour
Average Delay in Seconds/Vehicle (Development-Induced Increase)
2024
Existing
2026
Background
2031
Background
2026
Projected
2031
Projected
Horton Highway and
Murfreesboro Road
NB Left Turn AM 77 sec 101 sec 114 sec 96 sec (-5) 132 sec (+18)
PM
SB Through/Right Turn AM 80 sec 114 sec 122 sec 124 sec (+10) 145 sec (+23)
PM 56 sec (+17) 55 sec (+11)
WB Through/Right Turn AM 77 sec 99 sec 118 sec 107 sec (+8) 154 sec (+36)
PM
EB Left Turn AM 76 sec 89 sec 66 sec (-10) 83 sec (-6)
PM
EB Through/Right Turn AM
PM 60 sec (+23) 52 sec (+10)
I-840 WB Ramps and
Horton Highway
WB Left Turn AM 65 sec 85 sec 373 sec (+308) 761 sec (+676)
PM 38 sec 126 sec 171 sec 712 sec (+586) 1,193 sec (+1,022)
WB Right Turn AM 38 sec 38 sec (+0) 161 sec (+123)
PM
I-840 EB Ramps and
Horton Highway EB Left Turn AM 96 sec 215 sec 305 sec 489 sec (+274) 1,754 sec (+1,449)
PM 552 sec 1,177 sec 1,613 sec 2,444 sec (+1,267) 6,655 sec (+5,042)
5 | Page
• Based on the presented traffic volumes and the methodologies in NCHRP Report 457 –
Evaluating Intersection Improvements: An Engineering Study Guide , turn lanes are
warranted at the following site accesses during different build years (shown in
parentheses) for the proposed development:
o Northbound right turn lane on Horton Highway at southern Site Access (2026)
o Southbound right turn lane on Horton Highway at southern Site Access (2031)
o Northbound right turn lane on Horton Highway at Malachi Lane/Site Access
(2026)
o Northbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026)
o Southbound right turn lane on Horton Highway at Malachi Lane/Site Access
(2026)
o Southbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026)
o Eastbound right turn lane on Murfreesboro Road at West Site Access (2026)
o Westbound left turn lane on Murfreesboro Road at West Site Access (2026)
o Westbound left turn lane on Murfreesboro Road at East Site Access (2031)
• Deceleration lengths for the recommended turn lanes are based on a 35-mph speed,
which is 10 mph lower than the 45 -mph posted speed limit south of the site on Horton
Highway and on Highway 96 . This is typical in constrained situations where vehicles are
assumed to begin decelerating in the adjacent through lane. North of the project site, the
posted speed limit is 35 mph on Horton Highway near the Highway 96 traffic signal.
• Recommended storage lengths were sourced from the Highway Capacity Manual based
on facility type and context as well as TDOT’s review of the preliminary design plans. The
recommended storage lengths are expected to be sufficient to accommodate projected
queues output from the capacity analysis.
• Intersection sight distance was not evaluated in the TIS as requested in the scoping call
by TDOT but were later provided with proposed site plans submitted to the County for
review. These exhibits show the available sight distance at the proposed intersections of
Highway 96 and the Triune East and Triune West accesses. Based on examination of those
exhibits, sufficient intersection sight distance is available at these locations. Exhibits were
not provided for the site accesses on Horton Highway; however, based on street view
imagery, it is anticipated that intersection sight distance at these locations is sufficient.
• Per TDOT’s request, SIDRA analysis was conducted for the intersection of Horton Highway
and Malachi Lane/Site Access. The significant volume northbound and southbound on
Horton Highway causes a single lane roundabout to operate at LOS F with significant
queues under projected con ditions. A multilane roundabout that provides additional
capacity for these movements would improve LOS and resolve queue issues; however,
this was not recommended in the TIS based on potential property restrictions.
6 | Page
Based on the review of traffic study, it appears that the operational analyses are based on
reasonably correct peak hour volumes, intersection laneage, and traffic control.
Recommended Infrastructure Improvements
Based on the operational analysis as well as signal and turn lane warran ts, the following
infrastructure improvements are recommended in the TI S. The timing of each improvement is
denoted in parentheses. For each set of improvements, a response is noted below.
1. Murfreesboro Road with Triune East Site Driveway (Phase 1 – 2026 and Phase 2 – 2031)
o Implement unsignalized intersection control (stop on minor street approach)
o Construction of northbound Site Driveway shared left/right turn lane
o Construction of westbound Murfreesboro Road left turn lane (595 feet total
length including taper, deceleration and storage)
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for improvements at this
intersection should be approved by TDOT and Williamson County prior to application
of any building permits for Phase 2, which includes all non-residential components of
the Triune East and Triune West sites. Construction of all recommended turn lanes
should be completed before issuance of building permits for Phase 2.
2. Improvements at Horton Highway and Murfreesboro Road (Phase 1 – 2026 and Phase 2 –
2031)
o Optimization of traffic signal timings including cycle lengths and splits
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. This should be completed following completion of both
phases in 2026 and 2031.
3. Murfreesboro Road with Triune West Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (stop on minor street approach)
o Construction of westbound Murfreesboro Road left turn lane (595 feet total
length including taper, deceleration and storage)
o Construction of eastbound Murfreesboro Road right turn lane (360 feet total
length including taper, deceleration and storage)
o Site Driveway northbound left turn lane (100 ft of storage plus taper) and
northbound right turn lane
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for these turn lane
improvements should be approved by TDOT and Williamson County prior to
submittal of the preliminary plat for Phase 1, which includes all residential
components of the Triune East and Triune West sites. Con struction of all
7 | Page
recommended turn lanes should be completed before submittal of the final plat for
Phase 1.
4. I
mprovements at Horton Highway and Malachi Lane/Site Access (Phase 1 – 2026)
o Implementation of signalized intersection control
o Construction of Horton Highway northbound left turn lane (355 feet total length
including taper, deceleration and storage) and northbound right turn lane that
extends through the upstream proposed driveway.
o Construction of Horton Highway southbound left turn lane (460 feet total length
including taper, deceleration and storage) and southbound right turn lane ( 360
f
eet total length including taper, deceleration and storage)
o Construction of eastbound Site Driveway to include one left turn lane (100 ft o f
s
torage plus taper), one through lane, and one right turn lane (100 ft of storage
plus taper)
o Construction of westbound Malachi Lane left turn lane (200 ft of storage plus
taper) and westbound through/right turn lane
o Due to the proximity of Malachi Lane with the existing gas station and proposed
Triune East/West Site Driveway s, northbound turn lanes will extend beyond
those driveways.
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. With implementation of traffic signal control, left turn
movements should all be protected-permitted phasing and should include right turn
overlaps where applicable.
D
esign and construction plans for improvements at this intersection should be
approved by TDOT and Williamson County prior to submittal of the preliminary plat
for Phase 1, which includes all residential components of the Triune East and Triune
West sites. Construction of all recommended turn lanes should be completed before
submittal of the final plat for lots 1 through 24 in Phase 1. The installation of traffic
signal control should be completed before submittal of the final plat for the 25
th lot.
5. H
orton Highway with Triune East/West Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (stop on minor street approach)
o Right-in-right-out (RIRO) operation for both East and West site driveways
o Construction of Horton Highway northbound right turn lane (255 feet total length
including taper, deceleration and storage) and southbound right turn lane ( 230
feet total length including taper, deceleration and storage)
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for these turn lane
improvements should be approved by TDOT and Williamson County prior to submittal
8 | Page
of the preliminary plat for Phase 1, which includes all residential components of the
Triune East and Triune West sites. Construction of all recommended turn lanes should
be completed before submittal of the final plat for Phase 1.
6. Horton Highway with I-840 EB and WB Ramps (Phase 1 – 2026)
o The installation of traffic signal control should be implemented but should
not be the sole responsibility of the developer for the Triune development.
Instead, solutions with TDOT and Williamson County regarding funding of
these regional improvements should be explored before full build -out of the
Triune Development. However, construction of residential components for
Phases 1-3 of Triune East and West should be permitted under existing traffic
control with coordination with TDOT and Williamson County.
Review Evaluation: As noted in the TIS analyses, the existing unsignalized
intersections of Horton Highway and the I-840 EB and W B Ramps both operate
unacceptably under existing peak hour conditions. The minor street stop -
controlled ramp movements experience heavy delays due to the high northbound
and southbound volumes on Horton Highway. Eight-hour volume warrants as
outlined in the MUTCD warrant the installation of a traffic signal at these
locations in 2024. The need for this signalization is further compounded with
additional background development growth and the proposed Triune Mixed-Use
development.
Based on coordination with TDOT, the need for signalization and additional
capacity at t hese ramps has already been identified through the RSAR safety
process. However, funding has not been allocated for the design or construction
in TDOT’s current 3 -Year Plan that extends through 2027. Therefore, the
installation of traffic signals and right turn deceleration lanes on Horton Highway
should be completed before building permits are issued for any non -residential
land uses in Phase 2 of the Triune Mixed -Use development. In addition and as
recommended in the TIS, the Triune Mixed -Use development should coordinate
with TDOT and Williamson County to participate in the funding of these
improvements.
7. Malachi Lane with Triune East Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (all-way stop)
Review Evaluation: Based on the projected volumes at this intersection and
historic crash data, all-way stop control is unlikely to be warranted. Therefore, it
is recommended that this intersection be designed and constructed as a two-way
stop intersection with stop-control implemented for the northbound approach of
the Triune East access.
9 | Page
All of the above infrastructure improvements should be constructed in tandem with the specific
phase identified above. For additional clarity, the following figures highlight the specific
improvements and their timing.
10 | Page
Figure 1: Location of Recommended Off-Site Improvements per TIS Recommendations and 3rd Party Review
11 | Page
Figure 2a: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review
12 | Page
Figur
e 2b: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review
13 | Page
Conclusion – Study Acceptance
The Triune Mixed-Use TIS submitted February 2025 includes all of the typically required traffic
study components and identifies reasonable and beneficial infrastructure improvements to be
made as a result of the proposed development . At this time, we recommend acceptance of the
current traffic study and its recommendations . Timing of the various improvements associated
with the various development phases should be incorporated into the conditions of approval as
noted in the review comments.
Should you have any questions or need additional information, please contact me.
Sincerely,
K
ayla Ferguson, PE, AICP
Burch Transportation, LLC
Item 21—Page 1 of 3
Reviewer: JYJ
Date: 8/13/2026
ITEM 2 1
P
RELIMINARY PLAT REVIEW FOR THE VILLAGES AT TRIUNE E AST
SUBDIVISION (REVISED), CONTAINING 59 SINGLE FAMILY LOTS, 63
TOWNHOME LOTS, AND T HREE (3) NON-RESIDENTIAL LOTS ON 63.78 ACRES
LOCATED OFF HORTON HIGHWAY IN THE 5TH VOTING DISTRICT (1 -2026-
310).
A
ttachments 21-1 Preliminary Plat
21-2 Aerial Photograph
21-3 Applicant’s Request for Revised Concept Plan Conditions
21-4 Revised Review Memo from County’s Traffic Consultant
21-5 Original Review Memo from County’s Traffic Consultant
A
rea 63.78 acres
Zoning Triune Character Area-3 (TCA-3)
Triune Character Area-4 (TCA-4)
Lots 59 Single-Family Lots
63 Townhome Lots
Three (3) Non-Residential Lots
Water Nolensville/College Grove Utility District
Sewer Triune Sewer Facility
Development Option Conservation Subdivision, Multi-Family and Non-Residential
Chapter 1101 Status Triune Planned Growth Area (TPGA)
Map and Parcel 113--- 05706, 05709, 05712, 07202 and 07203
F
ile Number (1-2026-310)
A
Revised Concept Plan for this development wa s approved at the June 2026 meeting,
which added three (3) non -residential lots and one (1) single-family residential lot. The
currently approved Preliminary Plat depicts only the residential component of the
development. The applicant is now requesting approval of a revised Preliminary Plat in
order to incorporate both the residential and non -residential components of the
development into a single Preliminary Plat. The revised Preliminary Plat is consistent with
that depicted on the revised Concept Plan.
D
uring Concept Plan review, a Traffic Impact Analysis was performed by the applicant
and reviewed by the County’s Traffic Consultant. Numerous roadway improvements were
required in association with the development, and the construction of these
improvements is currently underway.
A
s a condition of approval, the applicant is required to install a traffic signal at the
intersection of Horton Highway and Malac hi Lane before the submittal of the Final Plat
containing the 25 th lot. At this time, the applicant is requesting modification of this
Item 21—Page 2 of 3
Reviewer: JYJ
Date: 8/13/2026
condition to allow the submittal of a Final Plat containing up to the 30th lot in Triune East
(this Item) and up to the 54 th lot in Triune West, which appeared as Item 20 on this
agenda, for a total of up to eighty -four (84) lots. The applicant has submitted a memo
documenting this request (See Attachment 21 -3), and this memo h as been reviewed by
the County’s Traffic Consultant (See Attachment 21 -4). The County’s Traffic Consultant
has noted allowing the applicant to submit Final Plats for the eighty -four (84) lots prior
to construction of the signal at Horton Highway and Mal achi Lane will not result in a
significant traffic impact to the surrounding roadway network. Therefore, the County’s
Traffic Consultant has recommended the modification of the condition to allow the
submission of a Final Plat containing up to the 30
th lot in Triune East, and that the
residential lots shall not be permitted to take access to Malachi Lane until the traffic signal
at the intersection of Horton Highway and Malachi Lane has been installed and is
operational.
Staff recommends approval of the Pre liminary Plat with the following conditions, which
shall be addressed in conjunction with Final Plat consideration:
1. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 31
st lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 2 1-4
and 21-5) shall be completed to the satisfaction of the Tennessee Department
of Transportation;
2. Except as noted in Number 3 below, prior to the submittal of th e Final Plat
containing the 31st lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 2 1-4
and 2 1-5) shall be completed to the satisfaction of the Williamson County
Highway Superintendent;
3. As specified by the County’s Traffic Consultant, the i nstallation of traffic signals
and construction of the right turn deceleration lanes on Horton Highway at the I-
840 Eastbound and Westbound Ramps shall be completed/constructed prior to
the issuance of building permits for any of the non -residential land uses;
4. The residential lots shall not be permitted to take access to Malachi Lane until the
traffic signal at the intersection of Horton Highway and Malachi Lane has been
installed and is operational;
5. At eighty -five percent (85%) build -out, Malachi Lane shall be repaved in its
entirety, as required by the Williamson County Highway Department;
6. Prior to the submittal of the first Final Plat, the required Zoning Certificate for
the wastewate r treatment and disposal system shall be submitted, and all
conditions associated with the wastewater site plan approval must be satisfied;
Item 21—Page 3 of 3
Reviewer: JYJ
Date: 8/13/2026
7. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by t he County Attorney’s office. The HOA
documents must address the greenway easement, the maintenance and
operation of t he private roads and gate that meet the standards , and
requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents
must be submitted with the Final Plat, and the approved HOA documents must
be recorded concurrently with the recording of the Final Plat;
8. A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning
Ordinance must be met;
9. Prior to the submittal of any Final Plat in which a greenway is located, the 12 -
foot-wide paved multi-modal greenway trail should be constructed;
10. Establishment of a performance bond for roads, d rainage and erosion control;
11. Establishment of a performance bond for water improvements in favor of
Nolensville/College Grove Utility District;
12. Establishment of a performance bond for the wastewater collection system;
13. Submission of landscaping plans and es tablishment of a performance bond for
landscaping improvements;
14. Execution of Performance Agreements for the above -referenced sureties;
15. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
16. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and
recording of the plat.
35' LDSB & MBSL
35' LDSB
25' LDSB
35' LDSB
30' MBSL
10' MBSL
30' MBSL
10' MBSL
10' MBSL
10' MBSL
30' MBSL
35' MBSL
15' LDSB
15' LDSB
15' LDSB
25' LDSB
15' LDSB
WET WEATHER CONVEYANCE
Red Oak 48"
Red Oak 34" Hollow
POND D
0+00
0+00
0+53
POND A
POND B
POND C
0+00
0+00
0+35
HENRY HORTON HIGHWAY
35' LDSB
35' LDSB
(PRIVATE) ALLEY
(PRIVATE) ALLEY
(PRIVATE) ALLEY
(PRIVATE) ALLEY
24
25
22
23
21
31
30
29
28
26
24
25
27
22
23
21
31
30
29
28
26
20
17
9
1
16
8
15
7
14
6
13
5
12
4
19
11
3
18
10
2
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
122
121
120
119
88
90
91
92
93
94
97
96
98
99
100
101
102
103
104
105
106
107
108 109
110
111
112
113
115
116
117
118
(PRIVATE) ALLEY
(PRIVATE) ALLEY
(PRIVATE) ALLEY
(PRIVATE) ALLEY
71
89
95
114
* *
**
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
50-FT WATERWAY
NATURAL AREA (WNA)
(STR-1)
50-FT WATERWAY
NATURAL AREA (WNA)
50-FT WATER
NATURAL AREA
(STR-3)
WETLAND AREA
(WTL-2)
50 FT BUFFER
WETLAND AREA
(WTL-1)
50 FT BUFFER
"UNT to NELSON CREEK"
STREAM (STR-2)
"UNT to NELSON CREEK"
STREAM (STR-2)
50-FT WATERWAY
NATURAL AREA
(STR-2)
NELSON CREEK
(STR-1)
WET WEATHER
CONVEYANCE WITH
DRAINAGE AREA GREATER
THAN 5 ACRES
(WWC-1/UDF-1)
25 FT DRAINAGE
EASEMENT
WETLAND AREA
(WTL-3)
*
*
*
*
*
*
TCA3
TCA2
TCA3
TCA4
TCA3
TCA2
TCA3TCA4
TCA3
*
*
*
TCA4
32
33
34
35
37
38
40
39
36
41
42
43
44
45
46
47
48
*
*
49
50
51
52
53
54
55
56
57
58
59 60
61 62 63
POND F
30' MBSL
25' LDSB
15' LDSB
10' MBSL
15' LDSB
PRIVATE ALLEY
PRIVATE ALLEY
64 65 66 67 68 69
70
10' MBSL
TAIL SHOT ROAD (PRIVATE DRIVE)
15' LDSB
Parcel Table
Lot #
124
125
126
Area
45626.64
49091.53
47398.83
123
ACRES
1.047
1.127
1.088
50' OPEN SPACE SET ASIDE
15' LDSB
MULTI-FAMILY PARENT PARCEL
OS 7
MULTI-FAMILY PARENT PARCEL
OS 9
124
125
126
Parcel Table
Lot #
OS 1
OS 2
OS 3
OS 4
OS 5
Area (SF)
26409.14
20368.65
550221.76
20806.62
396405.80
Area (AC)
0.61
0.47
12.63
0.48
9.10
OS 6 91287.20 2.10
OS 7 25091.20 0.58
OS 8 40381.17 0.93
OS 9 23690.55 0.54
OS 10 104292.07 2.39
OS 11 202946.66 4.66
OS 12 9645.12 0.22
MULTI-FAMILY PARENT PARCEL
OS 6
MULTI-FAMILY PARENT PARCEL
OS 8
MULTI-FAMILY PARENT PARCEL
OS 9
OS 1
OS 2
OS 3
OS 5
OS 4
30' MBSL
15' LBSD
30' MBSL
35' MBSL
35' MBSL
50' MAX FRONT MBSL
50' MAX FRONT MBSL
35' MBSL
50' MAX FRONT MBSL
35' LDSB
35' LDSB
SCALE: 1"=200'
SURVEY DIVISION
214 Centerview Drive Suite 300
Brentwood, TN 37027
615.370.8500
615.370.8530
woldae.com
Contact
John Powell
Ashby Communities, LLC.
P.O. Box 190 Arrington, TN 37014
(615) 496-8681
SITE ADDRESS:
8030 hORTON HWY
Arrington, TN 37014
06
91
.SSE
ET
NN
NEE O
CRITICAL LOTS:
PROPOSED SINGLE FAMILY LOTS THAT
HAVE EXISTING CRITICAL SLOPES ARE
INDICATED WITH THIS SYMBOL. AN
ENGINEERED SITE PLAN SHALL BE SUBMITTED
AND APPROVED BY WILLIAMSON COUNTY
ENGINEERING DEPARTMENT.
LOTS: 12, 13, 14, 15, 16, 19, 20, 21, 22,
25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35,
36, 37, 38, 39, 40, 43, 44, 45, 46, 47, 48,
49, 50, 51, 52, AND 59 ARE INDICATED AS
CRITICAL SLOPE LOTS.
ATTACHMENT 21-1
ATTACHMENT 21-2
July 20, 2026
Mr. Aaron Holmes, AICP - Planning Director
Williamson County Planning Commission
1320 West Main Street Suite 400
Franklin, TN 37064
Re: Villages at Triune West & East – Request for Revised Concept Plan Conditions
Williamson County, Tennessee
Dear Mr. Holmes,
We respectfully request that Williamson County allow for the submittal and approval of a phased final
plat for the residential lots within the development to be served exclusively by the approved site driveway
connections to Murfreesboro Road (S.R. 96) for both the Villages at Triune West and Villages at Triune
East developments. This request is based on the Traffic Impact Study (TIS) prepared by Civil &
Environmental Consultants, Inc. (CEC), revised February 2025, and is supported by updated intersection
capacity analysis (CEC, July 2026) demonstrating that the proposed plats operate within the traffic
volumes and levels of service those intersections were designed and analyzed to accommodate.
The current conditions of approval associated with the development require that all of the offsite roadway
improvements be installed and approved by TDOT prior to being able to submit for a Final Plat for more
than 24 residential units from either the Villages at Triune West or East subdivisions. This is based on the
assumption that the existing intersection of Horton Highway and Malachi Lane restricts what traffic can be
discharged at that intersection under current unsignalized conditions.
The developer is preparing to submit the first final plats for both the West and East sides in time to
appear on the October 2026 Planning Commission meeting agenda. The proposed first final plats are as
follows:
• Villages at Triune West — First Final Plat: 54 residential units (mix of single-family and
townhomes), to be submitted in advance of the October 2026 Planning Commission meeting.
• Villages at Triune East — First Final Plat: 30 residential units (mix of single-family and
townhomes), submitted on the same schedule for the October 2026 Planning Commission meeting.
The timing of this request is driven by the construction schedule of the signalized intersection at Horton
Highway and Malachi Lane, which is not anticipated to be complete and open to traffic until December
2026 — after the targeted October Planning Commission approval of these first final plats. As detailed in
the following sections, the traffic analysis in this letter accounts for that interim condition and confirms that
the S.R. 96 intersections can accommodate the proposed plats within the volumes already studied and
approved. Additionally, if allowed and approved by the Planning Commission at the October 2026
meeting, the recording of the Final Plat and then construction of the homes within the plat can begin. It is
anticipated that the homes from the first plat would not be fully constructed until well into 2027, with the
traffic signal fully installed and operating.
CURRENT CONDITIONS OF APPROVAL — RESIDENTIAL
The Triune development received approval for the following residential program, as analyzed at full
build-out in the CEC TIS:
ATTACHMENT 21-3
Table 1 — Approved Residential Program
Development Area Single-Family Townhomes Total Units
Triune West 99 213 312
Triune East 58 64 122
Total 157 277 434
With respect to platting and access, the existing condition of approval limits residential development to a
combined total of 24 residential lots across both the East and West sides prior to installation of the
signalized intersection at Horton Highway (U.S. 31A/41A/S.R. 11) and Malachi Lane (the “Malachi Lane
Signal”). This interim limit reflects the TIS assumption that the Malachi Lane Signal would be operational to
serve as the principal access for Triune East and a significant secondary access for Triune West at the time
residential occupancy commenced.
BASIS FOR THIS REQUEST — INTERIM ACCESS DURING CONSTRUCTION
The approved development includes a second primary access connection via the Malachi Lane Signal,
which the TIS analyzed as the principal point of access for the Triune East site and a significant secondary
access for Triune West. Construction of that signalized intersection is about to begin; however, it is not
anticipated to be open to traffic until December 2026.
During the interim period prior to the Malachi Lane Signal opening, the S.R. 96 site driveways will serve as
the sole access connection for residential traffic on both the West and East sides of the development.
Under this scenario, 100% of the vehicle trips generated by the platted residential units will be routed
through the S.R. 96 intersections.
The 24-lot interim limit would unduly constrain the initial development phase during the intervening period
despite the availability of adequate capacity at the S.R. 96 site driveways, which were designed and
analyzed to accommodate substantially higher volumes at full build-out. As demonstrated by the updated
capacity analysis below, the requested 54 (West) and 30 (East) units can be accommodated at the S.R. 96
driveways during the interim period at acceptable levels of service. Once the Malachi Lane Signal is open,
residential trips will distribute across all approved access points per the TIS distribution percentages,
materially reducing the S.R. 96 share and permitting the platting of any remaining residential units without
further constraint.
TRIP GENERATION — REQUESTED UNITS
Trip generation for the requested first final plats was prepared by CEC using ITE Trip Generation, 12th
Edition (average rates), for Land Use Code 210 (Single-Family Detached Housing) and Land Use Code
215 (Single-Family Attached Housing / Townhomes). The results, which serve as the basis for the interim
capacity analysis, are summarized below.
Table 2 — Triune West First Final Plat (54 Units): Trip Generation
Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total)
Single-Family (210) 15 148 3 / 2 / 17 9 / 5 / 14
Townhome (215) 39 276 5 / 13 / 18 11 / 9 / 20
West Total 54 424 8 / 21 / 29 20 / 14 / 34
Table 3 — Triune East First Final Plat (30 Units): Trip Generation
Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total)
Single-Family (210) 8 89 2 / 4 / 6 5 / 2 / 7
Townhome (215) 22 155 3 / 7 / 10 6 / 5 / 11
East Total 30 244 5 / 11 / 16 11 / 7 / 18
No internal capture or pass-by reductions were applied to the residential trip generation, consistent with
the TIS treatment of the residential land uses. During the interim phase, 100% of these trips are assigned
to the respective S.R. 96 site driveways, as reflected in the CEC analysis.
INTERIM TRIP DISTRIBUTION
During the interim phase, because no access is provided at Malachi Lane, 100% of the trips generated by
the requested residential units are assigned to the respective S.R. 96 site driveways. These trips will follow
the trip distribution from the original TIS and a figure has been provided in the attachments showing the
percentage of trips assigned.
The Triune West driveway lies approximately 1,600 feet west of the Horton Highway / S.R. 96
intersection, and the Triune East driveway approximately 2,300 feet east of it. The intersection therefore
lies between the two driveways. Only West site trips traveling east, and East site trips traveling west,
traverse the Horton Highway / S.R. 96 intersection — approximately 21 A.M. and 25 P.M. peak-hour site
trips, or roughly 1% of the existing intersection volume. This distribution is reflected in the 2026 Build
turning-movement volumes used in the capacity analysis below.
INTERIM CAPACITY ANALYSIS — 2026 BUILD CONDITIONS
At the County's request, CEC performed a peak-hour capacity analysis of the three study intersections that
serve or are traversed by interim site traffic, using the Highway Capacity Manual, 7th Edition
methodology in Synchro Version 12, consistent with the TIS. The interim (2026 Build) volumes were
developed by adding the site trip generation above — assigned 100% via the S.R. 96 driveways per the
interim access condition — to the 2026 No-Build turning-movement volumes from the TIS. The analysis
reflects the committed turn-lane improvements at each S.R. 96 driveway that are currently under
construction and will be finished by the time the first final plat will be submitted. Results for the weekday
A.M. and P.M. peak hours are presented below.
S.R. 96 Site Driveways (Unsignalized, Two-Way Stop Control)
Both S.R. 96 site driveways operate at an overall intersection delay of less than one second per vehicle
(LOS A) in both peak hours. The stop-controlled northbound site-exit approaches operate at acceptable
levels of service with negligible queuing (95th-percentile queues of less than one vehicle). The
Murfreesboro Road left-turn movements entering the driveways operate at LOS A–B.
Table 4 — 2026 Build LOS & Delay: S.R. 96 Site Driveways
Intersection / Movement AM LOS
(Delay)
AM
95% Q
PM LOS (Delay) PM
95% Q
West Dwy — WB Left (into dwy) A (8.1) 0 B (10.8) 0.1
West Dwy — NB Left (exit) E (36.0) 0.1 E (35.2) 0.1
West Dwy — NB Right (exit) B (10.5) 0.1 C (19.2) 0.1
West Dwy — NB approach C (15.4) — C (22.7) —
Intersection / Movement AM LOS
(Delay)
AM
95% Q
PM LOS (Delay) PM
95% Q
West Dwy — Overall A (0.3) — A (0.3) —
East Dwy — WB Left (into dwy) A (7.5) 0 A (8.8) 0
East Dwy — NB approach (exit) B (14.6) 0.1 C (16.4) 0.1
East Dwy — Overall A (0.2) — A (0.2) —
The northbound left-turn movement at the West driveway reflects LOS E; this is typical of a low-volume
minor-street left turn crossing a higher-volume arterial under stop control and involves only a handful of
vehicles per hour (a 95th-percentile queue of less than one vehicle). It does not affect the overall driveway
operation, which remains LOS A.
Horton Highway / S.R. 96 (Signalized)
The Horton Highway / S.R. 96 signalized intersection was analyzed under both the 2026 No-Build and
2026 Build (with 84 interim units) conditions. The results demonstrate that the interim plats do not degrade
the overall operation of this intersection relative to the No-Build condition. In the A.M. peak hour, the
overall intersection delay under the Build condition is essentially unchanged from — in fact marginally
better than — the No-Build condition. In the P.M. peak hour, the overall level of service remains within one
grade of the No-Build condition.
Table 5 — Horton Hwy / S.R. 96: 2026 No-Build vs. 2026 Build (84 Units)
Approach AM No-Build AM Build PM No-Build PM Build
Murfreesboro Rd — Eastbound D (37.0) C (30.5) C (30.9) D (39.6)
Murfreesboro Rd — Westbound F (92.5) F (93.9) C (28.3) C (26.3)
Horton Hwy — Northbound E (65.7) E (56.9) C (27.1) C (30.0)
Nolensville Rd — Southbound F (111.2) F (117.9) D (37.1) D (48.8)
Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8)
The westbound and southbound approaches reflect LOS F in the A.M. peak hour under both the No-Build
and Build conditions. This is a pre-existing regional congestion condition at this intersection that is present
with or without the interim plats; the addition of the 84 interim units does not change the overall A.M. level
of service (LOS E in both cases) and in fact slightly reduces overall delay. As documented in the TIS,
improvements at this intersection are tied to regional conditions and the broader Horton Highway corridor
rather than to this residential phase.
DISCUSSION OF INTERIM IMPACTS
The updated CEC capacity analysis confirms that the requested interim plats can be accommodated during
the period prior to installation of the Malachi Lane Signal without adverse operational impact at the study
intersections:
• S.R. 96 site driveways: Both driveways operate at overall LOS A in both peak hours, with 95th-
percentile queues of less than one vehicle on the stop-controlled site-exit approaches. The
committed turn-lane improvements accommodate entering and exiting movements without
impeding S.R. 96 through-traffic. The interim volumes (29 West / 16 East in the A.M.; 34 West /
18 East in the P.M.) represent less than 3% of the existing S.R. 96 mainline traffic at each location.
• Horton Highway / S.R. 96 signalized intersection: Only approximately 21 A.M. and 25 P.M.
site trips traverse this intersection — roughly 1% of its total entering volume. The analysis confirms
the interim plats do not degrade the overall level of service: the A.M. peak remains LOS E (with
slightly lower overall delay than No-Build), and the P.M. peak remains within one grade of No-
Build. The LOS F approaches present in the A.M. peak are pre-existing regional conditions
independent of this residential phase.
• Relationship to the analyzed full build-out: The TIS analyzed each of these intersections under
the full build-out condition — the entire 434-unit residential program plus all commercial land uses
— and identified the improvements necessary to maintain acceptable operations. The interim
phase places only a small fraction of that analyzed volume on the network, entirely via the S.R. 96
driveways, and therefore operates well within the previously accepted envelope.
CONCLUSION
This letter documents the current residential conditions of approval, the specific interim plat modification
requested (54 units West / 30 units East, all single-family and townhome product), the interim access
configuration in which all site access is provided exclusively via the S.R. 96 driveways with no Malachi Lane
access until the signal is complete, the trip generation for the requested units, and the updated CEC
capacity analysis of the three study intersections. That analysis confirms that the S.R. 96 site driveways
operate at overall LOS A, and that the Horton Highway / S.R. 96 signalized intersection is not degraded
by the interim plats relative to the 2026 No-Build condition.
All required roadway improvements at each S.R. 96 driveway are committed conditions of development
approval. Upon completion and opening of the Malachi Lane / Horton Highway signalized intersection —
anticipated December 2026 — residential trips will distribute across all approved access points consistent
with the TIS, and the developer will plat all remaining units in accordance with the full build distribution
model.
We respectfully request that the Planning Commission revise the approved conditions to allow for the
phased final plat approach described herein and are available to meet or provide any additional
information at your convenience.
Sincerely,
Will Crunk, PE
Crunk Engineering LLC
1 | P a g e
MEMORANDUM
To: Aaron Holmes, Williamson County Planning Department
From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC
Date: 8/5/26
Subject: Triune Mixed-Use – Requested Conditions of Approval Revisions
Introduction
The Triune Mixed -Use development includes a combination of residential and commercial
components located at the intersection of Horton Highway (US 41/SR 11) and Murfreesboro Road
(SR 96) in unincorporated Williamson County. Following submittal and review of a Traffic Impact
Study (TIS) according to the County’s guidelines, the development was approved with conditions,
and construction of the first development phase, which includes all residential components split
on the east and west sides of Horton Highway, began in 2026.
The conditions of approval placed on the development included multiple requirements specific to
off-site transportation improvements and their timing relative to preliminary and final plat
submittals. As residential lots continue to be submitted for preliminary and final plats, the off-site
improvements recommended in the February 2025 TIS are being constructed as required.
One specific condition of approval included construction of a traffic signal at the intersection of
Horton Highway and Malachi Lane, which will serve as a primary access to both Triune East and
West at full buildout. This signal was required to be constructed and operational before the 25 th
residential lot was submitted for final plat based on the existing and projected traffic volumes at
this intersection. According to the developer’s engineer, Crunk Engineering, construction of this
signal has been delayed but is still on track to be completed by the end of 2026 , which the
development team claims will be well in advance of any residential units being completed .
Therefore, the applicant is requesting a change to the existing conditions of approval in order to
adhere to their desired development timeline. More specifically, the applicant is requesting that
they be allowed to submit final plats for 84 residential units (60 more than is currently allowed)
prior to the traffic signal being constructed. The applicant has submitted a memo documenting
this request, including supplemental traffic operational analysis to evaluate the potential interim
condition in which 84 lots are constructed but access to Malachi Lane is not provided, routing all
development-generated traffic through the two site accesses on Murfreesboro Road and the
intersection of Horton Highway and Murfreesboro Road.
ATTACHMENT 21-4
2 | P a g e
Analysis Review
In order to evaluate the proposed interim access condition, a small-scale traffic impact analysis
was conducted with standard components – trip generation, trip distribution and assignment, and
capacity analysis – all described below.
• Trip Generation - The projected trip generation was calculated for both Triune East, which
includes a proposed 15 single family homes and 39 townhomes, and Triune West, which
includes a proposed 8 single family homes and 22 townhomes, for a combined 84
residential dwelling units. The trip generation calculations do not follow the latest version
of ITE’s Trip Generation Manual, 12th Edition, as stipulated in the memo, nor do they use
industry standard practice of using the fitted curve equations as appropriate; however,
with the relatively low number of dwelling units proposed, the discrepancy in trips
generated is unlikely to make a difference in the operational outcomes.
• Trip Distribution and Assignment – Under the interim access condition, all trips
generated by the additional 84 residential units would utilize the Triune East and Triune
West accesses on Murfreesboro Road. According to the 2025 TIS, trips generated by the
development were expected to be oriented as follows:
o 25% of trips to/from I-840 WB ramps
o 20% of trips to/from I-840 EB ramps
o 20% of trips to/from the west on Murfreesboro Road
o 15% of trips to/from the east on Murfreesboro Road
o 10% of trips to/from south on Horton Highway
o 10% of trips to/from north on Horton Highway/Nolensville Pike
With access limited to Murfreesboro Road, trips would redistribute at the two accesses
and at the signalized intersection of Horton Highway and Murfreesboro Road. The
following turning movements would see higher volumes during peak periods:
o Eastbound right turns on Murfreesboro Road at the Triune East access
o Westbound left turns on Murfreesboro Road at the Triune West access
o Northbound left and right turns on Horton Highway at the existing signal
o Eastbound right and westbound left turns on Murfreesboro Road at the existing
signal
It should be noted that the northbound and southbound through volumes on Horton
Highway at the existing Malachi Lane intersection will also increase with the redistribution
of traffic volumes generated by the 84 residential units . While not included in the
requested analysis, it can be anticipated that any additional through volume on the major
street will increase delays for the minor street volumes that exist today.
3 | P a g e
• Capacity Analysis – Capacity analysis was completed for both projected 2026 AM and PM
peak hours under the interim access scenario. The analyses account for the conditioned
off-site improvements at both Murfreesboro Road accesses as they will be complete prior
to construction of any residential units. The volumes, traffic control, and intersection
geometry utilized in the projected analyses are reasonably correct. Table 1 summarizes
the level of service (LOS) and vehicular delay projected at the three study intersections
under the 2026 background, or no-build, condition as well as the 2026 projected, or build,
condition during which access to Malachi Lane is not provided and all residential trips for
the proposed 84 residential units is routed through the Murfreesboro Road accesses.
The capacity analysis addressed the AM and PM peak hours at three intersections: the
existing signalized intersection of Horton Highway and Murfreesboro Road, and the two
unsignalized Murfreesboro Road driveways serving Triune East and Triune West. The no-
build condition reflects the intersection geometry, traffic control, and signal timing
documented in the February 2025 TIS, and the build condition adds the redistributed trips
from the interim access scenario described above. The two driveway intersection s are
shown only under the build condition, since they do not exist without the development.
One item in the capacity analysis should be noted. The signal timing at Horton Highway
and Murfreesboro Road was not held constant between the no-build and build scenarios;
the cycle length was shortened along with the retiming. In the AM peak hour, the overall
cycle length dropped from approximately 190 seconds under no-build to approximately
150 seconds under build, and in the PM peak hour it dropped from approximately 103
seconds to approximately 88 seconds, even though the traffic volumes at this intersection
are nearly identical between the two scena rios. Because the timing plan changed at the
same time as the volumes, the delay and LOS differences reported for this intersection
reflect the combined effect of both variables, and the operational impact of the additional
84 units cannot be isolated from the effect of the signal retiming. The shorter cycle s
improve LOS for movements with excess capacity but push already -saturated
movements, including the WB and SB through movements, further past capacity,
worsening their delay and queuing. The net effect is a slight improvement in the AM peak,
where the intersection was already failing, but a full LOS drop from C to D in the PM peak,
where it previously was not.
Setting aside the signal timing discrepancy at Horton Highway and Murfreesboro Road,
the additional volumes generated by the interim access scenario are expected to have a
limited effect on operations at the three study intersections. The two new driveways
operate at LOS C or better for nearly all movements, with the exception of the
northbound left turn at the Triune West driveway, which operates at LOS E in both peak
hours and is expected for an unsignalized minor street approach movement along an
4 | P a g e
arterial. The existing signalized intersection already operates at LOS E in the AM peak hour
and LOS C to D in the PM peak hour under the no -build condition, and the incremental
delay attributable to the added 84 units, apart from the timing changes discussed above,
is small relative to the background condition. Only one movement, the northbound left
turn, deteriorates in LOS between the no-build and build conditions during the PM peak
hour. Given that this condition is temporary and will be resolved once the Malachi Lane
signal is constructed, these results do not support a requirement for additional off -site
infrastructure improvements to accommodate the interim access scenario.
Table 1. Comparison of 2026 Background (No-Build) and Projected (Build) Peak Hour Operations
Intersection/Movement
LOS (Vehicular Delay in sec/veh)
AM
No-Build
AM
Build
PM
No-Build
PM
Build
Murfreesboro
Road and
Horton
Highway/
Nolensville
Pike
EB Left Turn E (76.0) E (58.0) C (23.3) C (21.5)
EB Through D (45.2) D (37.9) D (36.6) D (52.5)
EB Right Turn C (21.8) B (19.4) C (26.7) C (30.4)
WB Left Turn D (42.6) C (34.5) C (27.9) C (26.0)
WB Through F (98.6) F (101.9) C (28.4) C (26.5) WB Right Turn
NB Left Turn F (100.9) F (87.2) C (27.5) D (37.0)
NB Through C (31.7) C (27.6) C (26.9) C (25.9) NB Right Turn
SB Left Turn D (46.3) D (38.1) C (23.7) C (21.2)
SB Through F (113.7) F (120.9) D (38.9) D (52.5) SB Right Turn
Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8)
Murfreesboro
Road and
Triune East
Driveway
WB Left Turn -- A (7.5) -- A (8.8)
NB Left Turn -- B (14.6) -- C (16.4)
Murfreesboro
Road and
Triune West
Driveway
NB Left Turn -- E (36.0) -- E (35.2)
NB Right Turn -- B (10.5) -- C (19.2)
WB Left Turn -- A (8.1) -- B (10.8)
5 | P a g e
Conclusion
Based on the review of the supplemental traffic operational analysis, allowing the applicant to
submit final plats for up to 30 lots in Triune East and up to 54 lots in Triune West for a total of 84
residential units prior to construction of the Malachi Lane signal1 is not expected to result in a
significant traffic impact to the surrounding roadway network. The interim access scenario, which
routes all development-generated trips through the two Murfreesboro Road driveways and the
existing signalized intersection at Horton Highway, results in relatively minor incremental delays
at the existing signal beyond what is already occurring under background conditions. This
condition is temporary by design and will be resolved once access from Triune East and West is
provided via Malachi Lane. Therefore, the request to submit final plats for the 84 lots, up to 30
lots in Triune East and up to 54 lots in Triune West, is reasonable provided that the residential
lots within Triune East and Triune West are not permitted to access Malachi Lane or the traffic
signal is constructed, which the applicant's engineer indicates remains on track for completion
by the end of 2026, well ahead of any residential units being constructed. Accordingly, I do not
recommend requiring additional off-site infrastructure improvements as a condition of
approving the applicant's request, and I recommend that residential lots in either Triune East
or Triune West shall not be permitted to take access to Malachi Lane until the traffic
signal at the intersection of Horton Highway and Malachi Lane is installed and operational
in order to protect the County and existing traffic on Malachi Lane from added development
traffic in the interim.
Should you have any questions or need additional information, please contact me.
Sincerely,
Kayla Ferguson, PE, AICP
Burch Transportation, LLC
1 The existing condition of approval limits residential development to a combined total of 24 residential lots
across both Triune East and West prior to installation of the signal .
1 | Page
MEMORANDUM
To: Aaron Holmes, Williamson County Planning Department
From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC
Date: 3/3/2025
Subject: Triune Mixed-Use TIS Review
Thi
s memorandum provides the findings of the independent review of the Triune Mixed -Use TIS
submitted to Williamson County Planning on 2/20/2025 for a concept plan submittal. The review
focused on the following three items: consistency with assumptions discussed in the traffic study
scoping and included in the executed MOUA, review of the traffic operational analyses, and
evaluation of recommended infrastructure improvements. Based on this review, we identify any
necessary modifications to the traffic study and/or the recommendations that ensure consistency
with the County’s Traffic Study Guidelines and mitigate impacts of the proposed project.
G
eneral Project Information and Traffic Study Scope
The Triune Mixed-Use development proposal includes a new development plan located on either
side of Horton Highway (US 41A/SR 11) between Murfreesboro Road (SR 96) and I -840 in the
Triune area of Williamson County. The proposed development plan is referred to as Triune East
and Triune West based on its bifurcation via Horton Highwa y. The two sites will each include a
mix of residential unit types and commercial space and have six total accesses proposed – two on
Murfreesboro Road and four on Horton Highway. Based o n the proposed density and trip
generation of the development, a Traffic Impact Study was required. A traffic study scoping call
was conducted with the applicant’s traffic study preparer on August 21, 2024. The outcome of
this meeting was an agreed upon set of assumptions and study parameters for the traffic study.
Table 1 identifies key traffic study elements and an evaluation of their consistency with the agreed
upon scope. As noted, the traffic study submitted accurately reflects the current concept plan and
the scope as agreed upon in the MOUA.
ATTACHMENT 21-5
2 | Page
Table 1: Review of Traffic Study Scope Elements
Project
Characteristic Documented in Traffic Study Consistent with MOUA?
Proposed Land
Use and Density
342 single-family residential units
98 multifamily residential units
42,400 sf restaurant space
54,400 sf retail space
45,000 sf supermarket
16,000 sf hardware store
50,400 sf office space
318-room hotel
Yes
No
Trip Generation AM: 1,184 total / 612 enter / 572 exit
PM: 1,777 total / 938 enter / 839 exit
Yes
No
Notes: Exact trip totals are
higher than presented in MOUA,
but calculations are appropriate
and correct.
Buildout and
Background
Growth
Buildout Horizon: 2026 / 2031
Annual Growth Rate: 1.0%
Site Specific Growth: Burns Property,
Troubadour, Kings Chapel, Hardeman Springs,
Fiddler’s Glen, and Patterson Road
Development
Yes
No
Study Area
Segments: Murfreesboro Road; Horton Hwy
Intersections:
• Horton Highway / I-840 EB ramp
• Horton Highway / I-840 WB ramp
• Horton Highway / Murfreesboro Road
• Horton Highway and Malachi Lane/Site Access
• Horton Highway / Triune East Site Access
• Horton Highway / Triune West Site Access
• Malachi Lane / Site Access
• Murfreesboro Road / Triune West Site Access
• Murfreesboro Road / Triune East Site Access
Yes
No
Notes: Additional site accesses
were included to reflect changes
in the site plan following the
MOUA execution.
Traffic Operational Analyses
The operational analyses for the intersections and roadway segments within the study area were
based on methods from Highway Capacity Manual. The following bullets highlight a review of the
analysis as documented in the TIA:
• Data to support the traffic analyses was collected from 7:00-9:00 AM and 4:00-6:00 PM
on Thursday, September 5, 2024 when local schools were in session.
• Based on the data collected and capacity analysis, there are multiple critical turning
movements that operate at LOS E or worse during existing peak hour conditions. More
specifically, minor street left turn movements on the I-840 eastbound and westbound
ramps as well as multiple movements at the signalized intersection of Murfreesboro
3 | Page
Road and Horton Highway/Nolensville Road all currently operate unacceptably during at
least one if not both peak hours.
• Background and projected capacity analysis is divided into two horizon years. The first
represents a 2026 buildout year, which is expected to include all of the proposed
residential density in the Triune East and Triune West developments. The second
represents a 2031 buildout year, which is expected to include all of the non-residential
density.
• Continued growth in the region as well as this specific area of the County add significant
peak hour volumes to the critical intersections over the 7-year buildout horizon. This
causes already-failing movements to further deteriorate with significant increases in
average vehicular delays during peak hours before construction of the Triune mixed-use
development. The most significant delay is predicted for vehicles turning left from the
stop-controlled I-840 eastbound ramp onto Horton Highway, averaging ~5 minutes per
vehicle in the AM peak hour and ~27 minutes per vehicle in the PM peak hour in 2031.
• Addition of the proposed Triune Mixed-Use project causes significant increases in delays
for aforementioned critical turning movements at existing intersections. Table 2
highlights the specific scenario in which critical turning movements are expected to
operate at LOS E (indicated with green shading) and the corresponding vehicular delay
expressed in seconds per vehicle. For the 2026 and 2031 projected scenarios, the
additional delay added by the proposed project is shown in parentheses.
• As shown in Table 2, the intersection of Horton Highway and Murfreesboro Road has
multiple movements that already operate at LOS E, but the relative increase of delay
caused by the Triune Mixed-Use development is low. For example, the proposed
development is expected to add a maximum of 36 seconds to any of these movements,
specifically the westbound through/right turn movement. It should be noted that TDOT
has plans to eventually widen the Murfreesboro Road in the vicinity of the Triune
Mixed-Use project. The widening of Murfreesboro Road will also include capacity
improvements at this intersection that will help to alleviate the existing and projected
delays. However, no funding is allocated for this project and the anticipated completion
is, therefore, unknown.
• By contrast, delays added to the unsignalized I-840 ramps with completion of the
proposed project are significant. Traffic signal warrant analyses were conducted to
determine if and when traffic volumes would justify the need for traffic signals at these
locations. According to methodology set forth in the MUTCD and the typical
requirement to satisfy an 8-hour volume warrant on State Routes like Horton Highway,
both of these ramp intersections warrant traffic signal control under existing conditions.
Further, the study notes that additional capacity will be needed along Horton Highway,
specifically right turn lanes onto the I-840 ramps, in addition to traffic signal control to
mitigate projected delays.
4 | Page
Table 2: Summary of Critical Existing Intersection Operations
Intersection Critical Movement Peak
Hour
Average Delay in Seconds/Vehicle (Development-Induced Increase)
2024
Existing
2026
Background
2031
Background
2026
Projected
2031
Projected
Horton Highway and
Murfreesboro Road
NB Left Turn AM 77 sec 101 sec 114 sec 96 sec (-5) 132 sec (+18)
PM
SB Through/Right Turn AM 80 sec 114 sec 122 sec 124 sec (+10) 145 sec (+23)
PM 56 sec (+17) 55 sec (+11)
WB Through/Right Turn AM 77 sec 99 sec 118 sec 107 sec (+8) 154 sec (+36)
PM
EB Left Turn AM 76 sec 89 sec 66 sec (-10) 83 sec (-6)
PM
EB Through/Right Turn AM
PM 60 sec (+23) 52 sec (+10)
I-840 WB Ramps and
Horton Highway
WB Left Turn AM 65 sec 85 sec 373 sec (+308) 761 sec (+676)
PM 38 sec 126 sec 171 sec 712 sec (+586) 1,193 sec (+1,022)
WB Right Turn AM 38 sec 38 sec (+0) 161 sec (+123)
PM
I-840 EB Ramps and
Horton Highway EB Left Turn AM 96 sec 215 sec 305 sec 489 sec (+274) 1,754 sec (+1,449)
PM 552 sec 1,177 sec 1,613 sec 2,444 sec (+1,267) 6,655 sec (+5,042)
5 | Page
• Based on the presented traffic volumes and the methodologies in NCHRP Report 457 –
Evaluating Intersection Improvements: An Engineering Study Guide , turn lanes are
warranted at the following site accesses during different build years (shown in
parentheses) for the proposed development:
o Northbound right turn lane on Horton Highway at southern Site Access (2026)
o Southbound right turn lane on Horton Highway at southern Site Access (2031)
o Northbound right turn lane on Horton Highway at Malachi Lane/Site Access
(2026)
o Northbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026)
o Southbound right turn lane on Horton Highway at Malachi Lane/Site Access
(2026)
o Southbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026)
o Eastbound right turn lane on Murfreesboro Road at West Site Access (2026)
o Westbound left turn lane on Murfreesboro Road at West Site Access (2026)
o Westbound left turn lane on Murfreesboro Road at East Site Access (2031)
• Deceleration lengths for the recommended turn lanes are based on a 35-mph speed,
which is 10 mph lower than the 45 -mph posted speed limit south of the site on Horton
Highway and on Highway 96 . This is typical in constrained situations where vehicles are
assumed to begin decelerating in the adjacent through lane. North of the project site, the
posted speed limit is 35 mph on Horton Highway near the Highway 96 traffic signal.
• Recommended storage lengths were sourced from the Highway Capacity Manual based
on facility type and context as well as TDOT’s review of the preliminary design plans. The
recommended storage lengths are expected to be sufficient to accommodate projected
queues output from the capacity analysis.
• Intersection sight distance was not evaluated in the TIS as requested in the scoping call
by TDOT but were later provided with proposed site plans submitted to the County for
review. These exhibits show the available sight distance at the proposed intersections of
Highway 96 and the Triune East and Triune West accesses. Based on examination of those
exhibits, sufficient intersection sight distance is available at these locations. Exhibits were
not provided for the site accesses on Horton Highway; however, based on street view
imagery, it is anticipated that intersection sight distance at these locations is sufficient.
• Per TDOT’s request, SIDRA analysis was conducted for the intersection of Horton Highway
and Malachi Lane/Site Access. The significant volume northbound and southbound on
Horton Highway causes a single lane roundabout to operate at LOS F with significant
queues under projected con ditions. A multilane roundabout that provides additional
capacity for these movements would improve LOS and resolve queue issues; however,
this was not recommended in the TIS based on potential property restrictions.
6 | Page
Based on the review of traffic study, it appears that the operational analyses are based on
reasonably correct peak hour volumes, intersection laneage, and traffic control.
Recommended Infrastructure Improvements
Based on the operational analysis as well as signal and turn lane warran ts, the following
infrastructure improvements are recommended in the TI S. The timing of each improvement is
denoted in parentheses. For each set of improvements, a response is noted below.
1. Murfreesboro Road with Triune East Site Driveway (Phase 1 – 2026 and Phase 2 – 2031)
o Implement unsignalized intersection control (stop on minor street approach)
o Construction of northbound Site Driveway shared left/right turn lane
o Construction of westbound Murfreesboro Road left turn lane (595 feet total
length including taper, deceleration and storage)
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for improvements at this
intersection should be approved by TDOT and Williamson County prior to application
of any building permits for Phase 2, which includes all non-residential components of
the Triune East and Triune West sites. Construction of all recommended turn lanes
should be completed before issuance of building permits for Phase 2.
2. Improvements at Horton Highway and Murfreesboro Road (Phase 1 – 2026 and Phase 2 –
2031)
o Optimization of traffic signal timings including cycle lengths and splits
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. This should be completed following completion of both
phases in 2026 and 2031.
3. Murfreesboro Road with Triune West Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (stop on minor street approach)
o Construction of westbound Murfreesboro Road left turn lane (595 feet total
length including taper, deceleration and storage)
o Construction of eastbound Murfreesboro Road right turn lane (360 feet total
length including taper, deceleration and storage)
o Site Driveway northbound left turn lane (100 ft of storage plus taper) and
northbound right turn lane
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for these turn lane
improvements should be approved by TDOT and Williamson County prior to
submittal of the preliminary plat for Phase 1, which includes all residential
components of the Triune East and Triune West sites. Con struction of all
7 | Page
recommended turn lanes should be completed before submittal of the final plat for
Phase 1.
4. Improvements at Horton Highway and Malachi Lane/Site Access (Phase 1 – 2026)
o Implementation of signalized intersection control
o Construction of Horton Highway northbound left turn lane (355 feet total length
including taper, deceleration and storage) and northbound right turn lane that
extends through the upstream proposed driveway.
o Construction of Horton Highway southbound left turn lane (460 feet total length
including taper, deceleration and storage) and southbound right turn lane ( 360
feet total length including taper, deceleration and storage)
o Construction of eastbound Site Driveway to include one left turn lane (100 ft of
storage plus taper), one through lane, and one right turn lane (100 ft of storage
plus taper)
o Construction of westbound Malachi Lane left turn lane (200 ft of storage plus
taper) and westbound through/right turn lane
o Due to the proximity of Malachi Lane with the existing gas station and proposed
Triune East/West Site Driveway s, northbound turn lanes will extend beyond
those driveways.
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. With implementation of traffic signal control, left turn
movements should all be protected-permitted phasing and should include right turn
overlaps where applicable.
Design and construction plans for improvements at this intersection should be
approved by TDOT and Williamson County prior to submittal of the preliminary plat
for Phase 1, which includes all residential components of the Triune East and Triune
West sites. Construction of all recommended turn lanes should be completed before
submittal of the final plat for lots 1 through 24 in Phase 1. The installation of traffic
signal control should be completed before submittal of the final plat for the 25
th lot.
5. Horton Highway with Triune East/West Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (stop on minor street approach)
o Right-in-right-out (RIRO) operation for both East and West site driveways
o Construction of Horton Highway northbound right turn lane (255 feet total length
including taper, deceleration and storage) and southbound right turn lane ( 230
feet total length including taper, deceleration and storage)
Review Evaluation: This recommended improvement is consistent with the analysis
presented and expectations. Design and construction plans for these turn lane
improvements should be approved by TDOT and Williamson County prior to submittal
8 | Page
of the preliminary plat for Phase 1, which includes all residential components of the
Triune East and Triune West sites. Construction of all recommended turn lanes should
be completed before submittal of the final plat for Phase 1.
6. Horton Highway with I-840 EB and WB Ramps (Phase 1 – 2026)
o The installation of traffic signal control should be implemented but should
not be the sole responsibility of the developer for the Triune development.
Instead, solutions with TDOT and Williamson County regarding funding of
these regional improvements should be explored before full build -out of the
Triune Development. However, construction of residential components for
Phases 1-3 of Triune East and West should be permitted under existing traffic
control with coordination with TDOT and Williamson County.
Review Evaluation: As noted in the TIS analyses, the existing unsignalized
intersections of Horton Highway and the I-840 EB and W B Ramps both operate
unacceptably under existing peak hour conditions. The minor street stop -
controlled ramp movements experience heavy delays due to the high northbound
and southbound volumes on Horton Highway. Eight-hour volume warrants as
outlined in the MUTCD warrant the installation of a traffic signal at these
locations in 2024. The need for this signalization is further compounded with
additional background development growth and the proposed Triune Mixed-Use
development.
Based on coordination with TDOT, the need for signalization and additional
capacity at t hese ramps has already been identified through the RSAR safety
process. However, funding has not been allocated for the design or construction
in TDOT’s current 3 -Year Plan that extends through 2027. Therefore, the
installation of traffic signals and right turn deceleration lanes on Horton Highway
should be completed before building permits are issued for any non -residential
land uses in Phase 2 of the Triune Mixed -Use development. In addition and as
recommended in the TIS, the Triune Mixed -Use development should coordinate
with TDOT and Williamson County to participate in the funding of these
improvements.
7. Malachi Lane with Triune East Site Driveway (Phase 1 – 2026)
o Implement unsignalized intersection control (all-way stop)
Review Evaluation: Based on the projected volumes at this intersection and
historic crash data, all-way stop control is unlikely to be warranted. Therefore, it
is recommended that this intersection be designed and constructed as a two-way
stop intersection with stop-control implemented for the northbound approach of
the Triune East access.
9 | Page
All of the above infrastructure improvements should be constructed in tandem with the specific
phase identified above. For additional clarity, the following figures highlight the specific
improvements and their timing.
10 | Page
Figure 1: Location of Recommended Off-Site Improvements per TIS Recommendations and 3rd Party Review
11 | Page
Figure 2a: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review
12 | Page
Figure 2b: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review
13 | Page
Conclusion – Study Acceptance
The Triune Mixed-Use TIS submitted February 2025 includes all of the typically required traffic
study components and identifies reasonable and beneficial infrastructure improvements to be
made as a result of the proposed development . At this time, we recommend acceptance of the
current traffic study and its recommendations . Timing of the various improvements associated
with the various development phases should be incorporated into the conditions of approval as
noted in the review comments.
Should you have any questions or need additional information, please contact me.
Sincerely,
Kayla Ferguson, PE, AICP
Burch Transportation, LLC
Item 22—Page 1 of 2
Reviewer: OCW
Date: 8/13/2026
ITEM 22
FINAL PLAT REVIEW FOR THE GROVE SUBDIVISION, SECTION 18,
CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND
VOTING DISTRICT (1-2026-414).
Attachment 22-1 Final Plat
22-2 Aerial Photograph
Area 9.02 acres
Lots 11
Zoning Rural Development-1 (RD-1)
Water Milcrofton Utility District
Sewer Nontraditional Wastewater Treatment and Disposal System
Development Option Conservation Subdivision
Chapter 1101 Status Rural
File Number (1-2026-414)
This Section consists of a portion of Phase 2, and Phase 14 . The applicant is now
requesting Final Plat approval of Section 18 of the developme nt, which contains eleven
(11) lots and 3.33 acres of Open Space. As this section is internal no landscaping is
required.
The plat is consistent in layout with that depicted on the Preliminary Plat.
Staff recommends approval of the Final Plat with the following conditions:
1. Establishment of a mai ntenance bond for water improvements in favor of
Milcrofton Utility District in the amount of $44,332.30 ;
2. Per the recommendation of the County’s Wastewater Consultant, establishment of
a performance bond for the wastewater collection system in the amount of
$137,924.71;
3. Execution of performance agreements for the above referenced sureties;
4. The approved HOA documents must be recorded concurrently with the recording
of the Final Plat;
5. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
Item 22—Page 2 of 2
Reviewer: OCW
Date: 8/13/2026
6. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
2021
2022
2023
2024
4035
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3001
2014
2013
2015
2016
2017
2018
1
2
3
4
5
6
7
8
9
10
11
OPEN SPACE 1
WILDINGS BOULEVARD
WILD HERON WAY
NATIVE PONY TRL
OPEN
SPACE 2
5195
5191
5187
5183
5179
5175
5201
5205
5209
5213
5217
5221
5223
The Grove
P1 Cover Sheet
Sheet Schedule
Final PlatP3
Final PlatP2
N
S
WE
Civil EngineeringLand Planning & ZoningLand Surveying
516 Heather PlaceNashville, TN 37204
(615) 297-5166
Dale & Associates
JAMES
E.
C
A
M
PBELL,II2861.ON
E
ESSENNE T
VX
I
AGRICULTURE
EC
R
E
M
M
O
C
REGISTERED
LAND
SURVEYOR
D&A PROJECT
#11053
SHEET:
P1
SHEET 1 OF 3
07/20/2026
P2
P3
Section 18 Final Plat of Phase 2 and Phase 14 Preliminary Plat
Portion of Parcel 29.02 on Map 135 and
All of Parcels 29.08 and 29.10 On Map 142
Total Area: 9.02 Acres, 392,854 Square Feet
Date: July 20, 2026
Certificate of Survey
I hereby certify that the subdivision plan shown and described hereon is true and
correct survey to the accuracy required by the Williamson County, Tennessee
Regional Planning Commission and that the monuments have been or will be placed
as shown hereon, to the specifications of the Subdivision Regulations, as approved by
the County Engineer.
James E. Campbell, II Revised Date
Certificate of Ownership
I (we) hereby certify that I am (we are) the owner(s) of the property shown
and that I (we) hereby adopt this plan of subdivision with my (our) free
consent, establish the minimum building restriction line, and that offers of
irrevocable dedications for all public streets, utilities and other facilities have
been filed as required by these regulations.
OwnerDate
Certificate of Approval of Utility Systems
I hereby certify that the following utility systems outlines on the final subdivision
plat entitled have been installed in accordance with current, local, and/or state
government requirements or that a surety bond has been posted with the
Planning Commission to assure completion of all required improvements in case
of default. Also, I certify that the hydraulic design criteria specified in Section 5.5
of Williamson County Subdivision Regulations have been met.
Date - Water SystemMike Jones - Microfton
Date - Sewer System Charles Hyatt - TN Wastewater System
Certificate of Approval for Recording
I hereby certify that the subdivision plat shown hereon has been found to
comply with the Subdivision Regulations for the Williamson County,
Tennessee, with the exception of such variances, if any, as are noted in the
minutes of the Planning Commission, and that it has been approved for
recording in the office of the County Register.
DateSecretary, Planning Commission
GENERAL NOTES:
1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE.
2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK
5382, PAGE 78.
3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN.
4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF
PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135.
5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE
TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983
(NAD83).
6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT
DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO
THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS
THAT A CURRENT TITLE EXAMINATION MAY REVEAL.
7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND
SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA.
8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE
SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA.
9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF
STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS.
10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS
AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN:
·MAP NUMBER: 47187C0380G
·EFFECTIVE DATE: 12/20/2024
11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE
WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE
RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA
PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION,
KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE
PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS
SITE.
12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING,
GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED
BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND
PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS
(WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER
MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN.
14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN
AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF
PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR
THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1
FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT.
15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES.
840
McCRORY CREEK
Harpeth River
Starnes Creek
Eudailey-
Covington Rd
Covington Rd
Eudailey-
Arno Rd
Arno-CollegeGrove Rd
Bethesda Arno Rd
Nathan Smith Rd
Arno Rd
Site Vicinity Map
NTS
Site
N
S
WE
1000100200
GRAPHIC SCALE
1" = 100'
ATTACHMENT 22-1A
EXISTING
RESIDENCE
WILDINGS BOULEVARD
NATIVE PONY TRL
OPEN SPACE 1
126,607 SQ. FT.
2.91 ACRES
2018
2019
2020
2021
2022
2023
2024
3002
3003
3004
3005
3006
3007
3008
3010
3001
OPEN SPACE 2
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
W
12''
1
2
3
4
5
6
7
(50' PUBLIC ROW)
THE GROVE PHASE 1, SECTION 2PLAT BOOK P56, PAGE 29
THE GROVE PHASE 2, SECTION 3
PLAT BOOK P58, PAGE 5
EXISTING
BUILDING
30' REAR
MBSL (TYP)
6.02'
30' REAR
MBSL (TYP)
35' FRONT
MBSL (TYP)
10' SIDE
MBSL (TYP)
WILD HERON WAY
HATCHED AREA REMOVED ON OPEN
SPACE 4 RECONFIGURATION
PLAT BOOK P88, PAGE 53
20' PUBLIC UTILITY
EASEMENT
3009
MATCHLINE
MATCHLINE
HATCHED AREA REMOVED ON OPEN
SPACE 4 RECONFIGURATION
PLAT BOOK P88, PAGE 53
8
9
S 74°37'41" E
222.53'
S 74°37'41" E
219.87'
S 59°45'01" E 209.46'
165.00'
S 44°08'09" E165.00'
S 28°31'22" E165.00'
S 12°51'36" E
165.00'
S 12°51'45" E
165.00'
S 77°08'15" W 168.12'
N 33°41'26" W
518.28'
N 14°12'16" E 9
19.28'144.52'
130.74'
74.00'
21.51'
N 77°08'07" E
128.42'
N 69°18'24" E
84.46'
N 53°40'14" E
84.21'
128.42'
39.70'
N 38°03'29" E
84.22'
87.45'
S 21°40'28" E
S 74°31'49" E
624.69'
103.26'
C3
C4
C5
C6
C7
S 15°23'52" W 426.67'
S 70°32'25" E
226.17'
119.25'
128.36'
130.72'
35' FRONT
MBSL (TYP)
EXISTING DRIVETO BE REMOVED
EXISTING BUILDINGTO BE REMOVED
20' PUBLIC UTILITY
EASEMENT
10' SIDE
MBSL (TYP)
42.32'
S 74°36'08" E227.76'
THE GROVE PHASE 2, SECTION 3
PLAT BOOK P58, PAGE 5
50' PERIMETER
BUFFERYARD
CLYDE D. LYNCH MARITAL TRUST -
LOUISE GILLESPIE LYNCH 2 YEAR
QUALIFIED PERSONAL RESIDENCE TRUST
MAP 135, PARCEL 29
DEED BOOK 6624, PAGE 296
PROPOSED 4" FORCE MAIN
25' DRAINAGE EASEMENT
20' PUDE & MTE EASEMENT
44.46'
20' PUDE
P2
P3
CLYDE D. LYNCH MARITAL TRUST -
LOUISE GILLESPIE LYNCH 2 YEAR
QUALIFIED PERSONAL RESIDENCE TRUST
MAP 135, PARCEL 29
DEED BOOK 6624, PAGE 296
OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1
PLAT BOOK P88, PAGE 40
OPEN SPACE 4
REVISED PLAT THE GROVE PHASE 1 SECTION 1
PLAT BOOK P88, PAGE 40
5195
5191
5201
5205
5209
5213
5217
5221
5223
EXISTING 8" FORCE MAIN
Civil EngineeringLand Planning & ZoningLand Surveying
516 Heather PlaceNashville, TN 37204
(615) 297-5166
Dale & Associates
D&A PROJECT
#11053
SHEET:
P2
SHEET 2 OF 3
N
S
WE
50050100
1-800-351-1111
E
SSENNT
EE
E
LA
S
L
TSY
C
ONE
M,
. ICN!GI
FEB
POTS
A
-C
LL
RO
E
UOY
D
GRAPHIC SCALE
1" = 50'
BEARINGS ARE RELATIVE TO
THE TENNESSEE STATE PLANE
COORDINATE SYSTEM NAD83
(CORS96) EPOCH 2002
= 5/8" CAPPED IRON ROD (NEW)
"DALE & ASSOCIATES"
= 5/8" IRON ROD (OLD)
"DALE & ASSOCIATES"
*UNLESS OTHERWISE NOTED
= FIRE HYDRANT
= CURB INLET
= WATER LINE
= SIDEWALK
W
= HEADWALL
= SEWER FORCE MAIN LINE
= OVERHEAD UTILITY LINEOH
FM
= AREA DRAIN
Prepared for:
The Grove
AREA TABLE
840
McCRORY CREEK
Harpeth River
Starnes Creek
Eudailey-
Covington Rd
Covington Rd
Eudailey-
Arno Rd
Arno-CollegeGrove Rd
Bethesda Arno Rd
Nathan Smith Rd
Arno Rd
Site Vicinity Map
NTS
Site
N
S
WE
Lot # Square Feet Acres
121,189 0.49
217,863 0.41
317,809 0.41
417,811 0.41
521,869 0.50
628,919 0.66
730,561 0.70
825,208 0.58
922,037 0.51
1022,614 0.52
1120,485 0.47
OPEN SPACE 1
18,107 0.42 OPEN SPACE 2
126,607 2.91
TOTAL 392,854 9.02
CURVE TABLE
CURVE DELTA ANGLE RADIUS ARC LENGTH CHORD BEARING CHORD LENGTH
C12°52'30" 525.00'26.34'S 06°32'13" E26.34'
C2
C3
C4 14°51'07" 475.00' 123.13'S 22°49'26" W122.78'
C5 15°36'52" 475.00' 129.45'S 38°03'25" W129.05'
C6 15°36'47" 475.00' 129.44'S 53°40'14" W129.04'
C7 15°39'37" 475.00' 129.83'S 69°18'26" W129.42'
14°12'24" 475.00' 117.78'S 00°52'16" E117.48'
9°09'56" 475.00'75.98'S 10°48'55" W75.90'
PUDE = PUBLIC UTILITY &
DRAINAGE EASEMENT
The Grove Section 18 Final Plat
of Phase 2 and Phase 14 Preliminary Plat
Located in the College Grove Community, and is the property of TVG Tennessee I, LLC,
Book 5382, Page 78 and Book 6528, Page 732, Registers Office Williamson County,
Tennessee
6437 Wildings Boulevard
College Grove, Tennessee 37046
Map 142, Parcel 29.08
Map 142 Parcel 29.10
Book 5382, Page 78
and
Map 135, Parcel 29.02
Book 6528, Page 732
Drawn By:NH
Checked By: EC
Scale: 1" = 50'
Date: 06/01/2026
R1 07/20/2026
Percentage
4.61 %
32.23 %
GENERAL NOTES:
1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE.
2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK
5382, PAGE 78.
3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN.
4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF
PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135.
5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE
TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983
(NAD83).
6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT
DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO
THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS
THAT A CURRENT TITLE EXAMINATION MAY REVEAL.
7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND
SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA.
8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE
SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA.
9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF
STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS.
10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS
AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN:
·MAP NUMBER: 47187C0380G
·EFFECTIVE DATE: 12/20/2024
11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE
WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE
RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA
PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION,
KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE
PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS
SITE.
12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING,
GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED
BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND
PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS
(WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER
MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN.
14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN
AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF
PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR
THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1
FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT.
15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES.
Revisions:
R1 07/17/2026
·Addressed Williamson
County Comments
posted on 07/13/2026,
Project ID 2180481.
ATTACHMENT 22-1B
3007
3008
3010
3011
W
12''
W
12''
W
12''
W
12''
W
12''
W
6
7
EXISTING
BUILDING
30' REAR
MBSL (TYP)
6.02'
HATCHED AREA REMOVED ON OPEN
SPACE 4 RECONFIGURATION
PLAT BOOK P88, PAGE 53
20' PUBLIC UTILITY
EASEMENT
3009
MATCHLINE
MATCHLINE
HATCHED AREA REMOVED ON OPEN
SPACE 4 RECONFIGURATION
PLAT BOOK P88, PAGE 53
8
9
10
11
WILDINGS BOULEVARD
(50' PUBLIC ROW)
CURVE
C1
C2
C3
C4
C5
C6
C7
S 74°37'41" E
222.53'
S 74°37'41" E
219.87'
N 14°12'16" E 9
19.28'144.52'
130.74'
74.00'
103.26'
124.19'
153.48'
C1
C2C3
97.53'
S 07°58'28" E 253.93'
S 15°23'52" W 426.67'
N 82°01'32" E
154.69'
N 82°01'32" E
201.57'
S 70°32'25" E
226.17'
120.67'
115.00'
18.26'
119.25'
128.36'
130.72'
35' FRONT
MBSL (TYP)
20' PUBLIC
UTILITY
EASEMENT
EXISTING DRIVETO BE REMOVED
EXISTING BUILDINGTO BE REMOVED
10' SIDE
MBSL (TYP)
30' REAR
MBSL (TYP)
4035
OPEN SPACE 2
THE GROVE, REVISED FINAL
PLAT, PHASE 1, SECTION 1
PLAT BOOK P59, PAGE 53
OPEN SPACE 2
18,107 SQ. FT.
0.42 ACRES
NATIVE PONY TRAIL
(50' PUBLIC ROW)
OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1
PLAT BOOK P88, PAGE 40
EXISTING 30" HDPE
OPEN SPACE 4
REVISED PLAT, THE GROVE
PHASE 1 SECTION 1
PLAT BOOK P88, PAGE 40
N 79°09'29" E
87.45'
80.14'
42.32'
S 74°36'08" E227.76'
S 84°13'19" E
226.55'
THE GROVE PHASE 2, SECTION 3
PLAT BOOK P58, PAGE 5
50' PERIMETER
BUFFERYARD
50' PERIMETER
BUFFERYARD
CLYDE D. LYNCH MARITAL TRUST -
LOUISE GILLESPIE LYNCH 2 YEAR
QUALIFIED PERSONAL RESIDENCE TRUST
DEED BOOK 6624, PAGE 296
12''
W
12''
W
12''
W
12''
W
20' DRAINAGE EASEMENT
20' PUDE
P2
P3
50' PERIMETER
BUFFERYARD
CLYDE D. LYNCH MARITAL TRUST -
LOUISE GILLESPIE LYNCH 2 YEAR
QUALIFIED PERSONAL RESIDENCE TRUST
MAP 135, PARCEL 29
DEED BOOK 6624, PAGE 296
OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1
PLAT BOOK P88, PAGE 40
5195
5191
5187
5183
5179
5175
5201
EXISTING 8" FORCE MAIN
1-800-351-1111
E
SSENNT
EE
E
LA
S
L
TSY
C
ONE
M,
. ICN!GI
FEB
POTS
A
-C
LL
RO
E
UOY
D
GRAPHIC SCALE
1" = 50'
BEARINGS ARE RELATIVE TO
THE TENNESSEE STATE PLANE
COORDINATE SYSTEM NAD83
(CORS96) EPOCH 2002
Civil EngineeringLand Planning & ZoningLand Surveying
516 Heather PlaceNashville, TN 37204
(615) 297-5166
Dale & Associates
D&A PROJECT
#11053
SHEET:
P3
SHEET 3 OF 3
N
S
WE
50050100
Prepared for:
The Grove The Grove Section 18 Final Plat
of Phase 2 and Phase 14 Preliminary Plat
Located in the College Grove Community, and is the property of TVG Tennessee I, LLC,
Book 5382, Page 78 and Book 6528, Page 732, Registers Office Williamson County,
Tennessee
6437 Wildings Boulevard
College Grove, Tennessee 37046
Revisions:
R1 07/17/2026
·Addressed Williamson
County Comments
posted on 07/13/2026,
Project ID 2180481.
840
McCRORY CREEK
Harpeth River
Starnes Creek
Eudailey-
Covington Rd
Covington Rd
Eudailey-
Arno Rd
Arno-CollegeGrove Rd
Bethesda Arno Rd
Nathan Smith Rd
Arno Rd
Site Vicinity Map
NTS
Site
N
S
WE
CURVE TABLE
CURVE DELTA ANGLE RADIUS ARC LENGTH CHORD BEARING CHORD LENGTH
C12°52'30" 525.00'26.34'S 06°32'13" E26.34'
C2
C3
C4 14°51'07" 475.00' 123.13'S 22°49'26" W122.78'
C5 15°36'52" 475.00' 129.45'S 38°03'25" W129.05'
C6 15°36'47" 475.00' 129.44'S 53°40'14" W129.04'
C7 15°39'37" 475.00' 129.83'S 69°18'26" W129.42'
14°12'24" 475.00' 117.78'S 00°52'16" E117.48'
9°09'56" 475.00'75.98'S 10°48'55" W75.90'
= 5/8" CAPPED IRON ROD (NEW)
"DALE & ASSOCIATES"
= 5/8" IRON ROD (OLD)
"DALE & ASSOCIATES"
*UNLESS OTHERWISE NOTED
= FIRE HYDRANT
= CURB INLET
= WATER LINE
= SIDEWALK
W
= HEADWALL
= SEWER FORCE MAIN LINE
= OVERHEAD UTILITY LINEOH
FM
= AREA DRAIN
PUDE = PUBLIC UTILITY &
DRAINAGE EASEMENT
AREA TABLE
Lot # Square Feet Acres
121,189 0.49
217,863 0.41
317,809 0.41
417,811 0.41
521,869 0.50
628,919 0.66
730,561 0.70
825,208 0.58
922,037 0.51
1022,614 0.52
1120,485 0.47
OPEN SPACE 1
18,107 0.42 OPEN SPACE 2
126,607 2.91
TOTAL 392,854 9.02
Percentage
4.61 %
32.23 %
GENERAL NOTES:
1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE.
2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK
5382, PAGE 78.
3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN.
4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF
PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135.
5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE
TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983
(NAD83).
6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT
DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO
THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS
THAT A CURRENT TITLE EXAMINATION MAY REVEAL.
7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND
SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA.
8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE
SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA.
9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF
STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS.
10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS
AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN:
·MAP NUMBER: 47187C0380G
·EFFECTIVE DATE: 12/20/2024
11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE
WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE
RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA
PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION,
KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE
PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS
SITE.
12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING,
GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED
BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT.
13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND
PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS
(WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER
MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN.
14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN
AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF
PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR
THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1
FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT.
15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES.
Map 142, Parcel 29.08
Map 142 Parcel 29.10
Book 5382, Page 78
and
Map 135, Parcel 29.02
Book 6528, Page 732
Drawn By:NH
Checked By: EC
Scale: 1" = 50'
Date: 06/01/2026
R1 07/20/2026
ATTACHMENT 22-1C
ATTACHMENT 22-2
Item 23—Page 1 of 1
Reviewer: OCW
Date: 8/13/2026
ITEM 23
FINAL PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRUST
SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1 -2026-415).
Attachment 23-1 Final Plat
23-2 Aerial Photograph
Area 32.12 acres
Zoning Rural Development-5 (RD-5)
Lots 1
Water Nolensville/College Grove Utility District
Sewer Individual On-Site Septic Systems
Development Option Large Lot Easement
Chapter 1101 Status Rural
File Number (1-2026-415)
A Preliminary Plat for this development was approved at the July 2026 Planning
Commission Meeting. The applicant is now requesting approval of the Final Plat ,
consisting of one ( 1) Family Subdivision lot. A Variance to allow the shared drive to be
less than the required sixteen (16) feet was granted at the July 2026 Planning Commission
meeting.
The Final Plat conforms with the approved Preliminary Plat, and Staff recommends
approval with the following conditions:
1. The applicant shall adopt and record a covenant that declares that the access
easement is not a public road, and imposes the requirement of maintenance by
all properties served by the access easement. The covenant shall b e recorded
concurrently with the recording of the plat;
2. The applicant shall submit a signed and notarized ‘Family Subdivision Affidavit
and Restrictive Covenant,’ which shall be recorded concurrently with the
recording of the plat. After the ‘Family Subdivision Affidavit and Restrictive
Covenant’ has been recorded and prior to application for building permits, t he
applicant shall provide a copy to the Planning Department application for
Building Permits; and
3. Satisfaction of Section 3.05 of the Subdivisi on Regulations, as it pertains to fire
apparatus access requirements for all lots, prior to building permit issuance.
(14.00)
DAVID M
. DODD, ETUX
DEED BOOK 9679, PAGE 382,
R.O.W
.C., TENNESSEE
BARN
BARN
EXISTING
RESIDENCE
EXISTING
RESIDENCE
SHED
(14.13)
CARL ANTHONY FOSTER
BOOK 9679, PAGE 359
R.O.W
.C., TENNESSEE
(14.12)
R.
O.W
.C.
, TENNESSEE
(14.14)(14.14)
DODD FAM
ILY REVOCABLE
LIVING TRUST
DEED BOOK 9715, PAGE 252,
R.O.W
.C., TENNESSEE
(14.
14)
DODD FAM
ILY REVOCABLE
LIVING TRUST
DEED BOOK 9715,
PAGE 252,
R.O.W
.C., TENNESSEE
(27)
PATRICIA A. S
HARP R
EV. L
IV. TRUST
DEED BOOK 9808, PAGE 805,
PLAT BOOK 14, PAGE 28, R.O.W
.C.,
TENNESSEE
EXISTING 50' INGRESS/EGRESS AND UTILITY EASEM
ENT
EXTENDS TO TALIAFERRO ROAD
(14.06)
M
cCONLOGUE FAM
ILY TRUST
DEED BOOK 7497, PAGE 539,
R.O.W
.C., TENNESSEE
N 82°39'18" W
698.47'
N 10°48'29" E 135.56'
LINE
BEARING
DISTANCE
L1
S 77
°39'54
" W
39
.65'
L2
S 83
°01'41
" E
32
.50'
L3
N 06
°49
'10"
E
20
.00'
L4
S 83
°10'50
" E
30
.00'
L5
N 83
°48
'16"
W
36
.54'
L6
S 82
°20'26
" E
53
.55'
L8
N 79
°19
'33"
W
33
.78'
L9
N 09
°34
'07"
E
56
.54'
L10
S 13
°09'50
" W
38
.75'
L11
N 82
°02
'24"
W
10
.00'
L12
S 77
°52'31
" E
5.00
'
C1
A3
A
B
C
D
E
F
G
H
DEED BO
OK 921, PAGE 931, R.O.W
.C., TN
POND
POND
POND
FLOW
FLOW
S 82°43'34" E
423.25'
L8
L9
L10
(27.
05
)
DONALD W
. ROLAND, ETUX
DEED BOOK 408
2, PAGE 63
5,
R.O.W
.C., TENNESSEE
LOT 6, PLAT BOOK 47
, PAGE 136
, R.O.W
.C.,
TN.
BARN
40' ELECTRIC TRANSM
ISSION EASEM
ENT
20'
(14.13)
SHED
EXISTING
RESIDENCE
(14.06)
M
cCONLOGUE FAM
ILY TRUST
DEED BOOK 7497, PAGE 539,
R.O.W
.C., TENNESSEE
25' DRAINAGE EASEM
ENT
25' DRAINAGE EASEM
ENT
1399190 Sq. Feet
32.12 Acres
REVISED
DEED BO
OK 10023, PAGE 543, R.O.W
.C., TN
EXISTING 50' INGRESS/EGRESS AND UTILITY EASEM
ENT
EXTENDS T
O TALIAFERRO ROAD
DEED BO
OK 921, PAGE 931, R.O.W
.C., TN
DEED BO
OK , PAGE , R.O.W
.C., TN
RE
VISED AND EXTENDED
N 79°49'38" W
355.10'
N 82°39'43" W
220.48'
N 10°49'22" E 440.60'
N
82°38'41" W
230.18'
N 07°52'37" E 700.00'
N 82°43'34" W
248.69'
S 07°35'21" W 303.03'
S 07°54'23" W 192.80'
S 07°54'23" W 230.11'
S 06°49'10" W 105.95'
S 83°01'50" E 149.97'
S 06°49'10" W 106.15'
S 10°40'27" W 162.63'
S 12°59'15" W 1151.28'
L1
L2
L3
L4
L5
C1
36.70'
44.81'
42.08'
N 42°02'25" W
69°57'32"
1
S 12°07'29" W 183.81'
N 83°07'08" W
155.78'
N 07°57'36" E 202.49'
(14.12)
BARTON J. MAGOWAN, ETUX
DEED BOOK 7075, PAGE 940,
R.O.W.C., TENNESSEE
L11
L12
50.00'
150.00
118.09'
(14.07)
DAVID DODD, ETUX
DEED BOOK 9679, PAGE 392,
R.O.W
.C., TENNESSEE
TURN AROUND
AREA
298.82'
346.88'
122.97'
50.00'
N 81°54'06" W
118.71'
N 10°37'00" E 139.48'
100' M
.B.S.L.
100' M
.B.
S.L.
100' M.B.S.L.
25' M.B.S.L.
100' M
.B.S.L.
50' M
.B.S.L.
25' M.B.S.L.
100' M
.B.S.L.
SITE
CERTIFICATE OF OWNERSHIP AND DEDICATION
I (we) hereby certify that I am (we are) the owner (s) of the property shown and described hereon,
as evidenced in Deed Book 9715, Page 252, R.O.W.C., TN, and that I (we) adopt this plan of
subdivision with my (our) free consent, establish the minimum building restriction line, and that
offers of irrevocable dedicated for all public streets, utilities and other facilities have been filed
as required by these Regulations.
______________________, 2026
_______________________________
DATE OWNER-DODD FAMILY REVOCABLE
LIVING TRUST
_______________________________
OWNER-
CERTIFICATE OF ACCURACY
I hereby certify that the plat shown and described hereon is true and correct survey to the
accuracy required by the Williamson County, Tennessee Regional Planning Commission, and
that the monuments have been or will be placed as shown hereon, to the specifications of the
Subdivision Regulations, as approved by the County Engineer.
______________________, 2026 ________________________________
DATE REGISTERED LAND SUR
VEYOR
TN. REG. NO. 1434
CERTIFICATE OF GENERAL APPROV AL FOR INSTALLATION OF SUBSURFACE
DISPOSAL SYSTEMS WITH RESTRICTIONS
General approval is hereby granted for lots proposed hereon as being suitable for subsurface
sewage disposal with the listed and/or attached restrictions.
Before the initiation of construction, the location of the house or other structure and plans the
for subsurface sewage disposal system shall be approved by the local health department.
______________________, 2026
________________________________
DATE DEPT. OF SEWAGE DISPOSAL MANAGEMENT
CERTIFICATE OF APPROV AL OF UTILITY SYSTEMS
I hereby certify that the following utility systems outlined or indicated on the final plat subdivision
entitled have been installed in accordance with current local and/or state government regulations or
that a surety bond has been posted with the Planning Commission to assure the completion of all the required
improvements in case of default. Also, I certify that the hydraulic design criteria specified in section
5.5 of the Williamson County Subdivision Regulations have been met.
WATER SYSTEM_____________, 2026 __________________ __________________
NAME, TITLE, AND AGENCY OF
AUTHORIZED APPROVING AGENT
CERTIFICATE OF APPROV AL FOR RECORDING
I hereby certify that the subdivision plat shown hereon has been found to comply with the
Subdivision Regulations of Williamson County, Tennessee, with the exception of such
variances, if any, as are noted in the minutes of the Planning Commission and it has been
approved for recording in the office of the County Register.
______________________, 2026 ________________________________
DATE SECRETARY , PLANNING COMMISSION
THIS APPROV AL SHALL BE INV ALID IF NOT RECORDED BY ____________________
Date
PROPERTY MAP REFERENCE
Being a portion of Parcel No.014.14 as shown on Williamson County Property Map No. 140
SPRING HILL, TN 37174
Fax: 615.523.1517
PH 615.481.3106
P.O. BOX 1636
Ahler & Associates, LLC
w
LEGEND
OE
GENERAL NOTES:
1. PLAN PR
EPARED FOR:
2 . DEED REFERENCE:
DEED BOOK 9715, PAGE 252. R.O.W.C., TN.
4. BEARINGS ARE BASED UPON
T
N STATE PLANE COODINATES
5. SUR
VEY IS SUBJECT TO ALL THE
FINDINGS AN ACCURATE TITLE SEARCH
WOULD REVEAL. NO TITLE FURNISHED
TO THIS SURVEYOR.
6. PHYSI
CALLY EVIDENT UTILITIES ARE
SHOWN BUT NOT WARRANTED.
CONTRACTOR SHALL CONTACT 811, 72
HOURS PRIOR TO ANY EXCA V ATION
AS PRESCRIBE BY STATE LAW.
ON THE FEMA FIS RATE MAP NO.
471187C0385G DATED 12-20-2024 &
8. THIS PROPERTY IS SHOWN AS ZONE "X"
3. TAX MAP 140, PARCEL 014.14
DODD FAMILY REVOCABLE LIVING TRUST
8491 TALIAFERRO ROAD
EAGLEVILLE, TN 37060
SCALE 1"=100'
LOCATION MAP
NTS
SHEET 1 OF 2
MATCH LINE
MATCH LINE
EAGLEVILLE, WILLIAMSON CO., TN. 37060
8491 TALIAFERRO ROAD
DODD FAMILY REVOCABLE LIVING TRUST
FINAL PLAT
9. THIS PROPERTY IS ZONED RD-5
10. THE MINIMUM REQUIRED BUILDING
SETBACKS: FRONT=100'
SIDE=25', REAR=50'.
7. THIS IS A CATEGORY IV SURVEY AS DEFINED
IN RUL 0820-03-.05 OF THE RULES OF THE TN
BOARD OF EXAMINERS FOR LAND SURVEYORS.
WE USED CARLSON BRx7 MULTI-FREQUECY GNSS
UNITS. THIS IS A REAL TIME KINEMATICS (RTK)
SURVEY WITH BASE-ROVER MODE UTILIZING
1983 EPOCH 2025.063 TN. STATE PLANE COORDINATES
GEOID 2018 AND A COMBINED GRID TO GROUND
SCALE FACTOR OF 1.0000123615. CONTROL W AS
ESTABLISHED USING THE TDOT NETWORK AND
NO FIXED STATIONS WERE USED.
THE PURPOSE OF THIS PLAT IS TO OBTAIN APPROV AL FOR
RELOCATION OF THE ACCESS EASEMENT ON PARCEL 14.14 TO
ALLOW FOR APPROV AL OF A RESERVE SEPTIC FIELD
PERC TEST
TRACT 3
5355 SQ. FT
3-BDRM MAX
60 MPI MLPP
0-5%
B
A
MINOR LARGE LOT SUBDIVISION
PETTUS RD
JUNE 15, 2026
SEPTIC TANK
SWITCH V ALVE
UNSUITABLE
471187C0395G DATED 12-20-2024
TYPICAL W
OODEN FENCE
4' IN HEIGHT, W
ITH THREE
RAILS
x x x FENCE
ATTACHMENT 23-1A
(14.00)
DAVID M
. DODD, ETUX
DEED BOOK 9679, PAGE 382,
R.O.W
.C., TENNESSEE
(14.13)
CARL ANTHONY FOSTER
BOOK 9679, PAGE 359
R.O.W
.C., TENNESSEE
(14.12)
BA
RTON J. M
AGOW
AN, ETUX
DEED BO
OK 7075, PAGE 940,
R.
O.W
.C.
, TENNESSEE
(14.14)
DODD FAM
ILY REVOCABLE
LIVING TRUST
DEED BOOK 9715, PAGE 252,
R.O.W
.C., TENNESSEE
BARN
EXISTING
RESIDENCE
(14.13)
CARL ANTHONY FOSTER
BOOK 9679, PAGE 359
R.O.W
.C., TENNESSEE
(14.13)
SHED
EXISTING
RESIDENCE
1399190 Sq. Feet
32.12 Acres
436671 Sq. Feet
10.02 Acres
S 07°54'23" W 192.80'
S 85°16'18" W
451.25'
S 06°51'46" W 221.89'
S 07°02'14" W 102.00'
S 05°52'57" W 211.11'
N 07°03'44" W 77.97'
N 77°01'11" W
106.46'
S 81°40'11" E 1
43.74'
S 82°12'14" E 125.14'
N 07°54'20" E 647.99'
S 07°54'23" W 230.11'
L6
C1
1
100' M
.B.S.L.
100' M.B.S.L.
25' M.B.S.L.
50' M
.B.S.L.
SPRING HILL, TN 37174
Fax: 615.523.1517
PH 615.481.3106
P.O. BOX 1636
Ahler & Associates, LLC
w
LEGEND
OE
SCALE 1"=100'
TALIAF
ERRO
ROAD
50' R.
O.W
.
TALIAFERRO ROAD 50' R.O.W
SHEET 2 OF 2
EAGLEVILLE, WILLIAMSON CO., TN. 37060
8491 TALIAFERRO ROAD
DODD FAMILY REVOCABLE LIVING TRUST
FINAL PLAT
MATCH LINE
MATCH LINE
GENERAL NOTES:
1. PLAN PR
EPARED FOR:
2 . DEED REFERENCE:
DEED BOOK 9715, PAGE 252. R.O.W.C., TN.
4. BEARINGS ARE BASED UPON
T
N STATE PLANE COODINATES
5. SUR
VEY IS SUBJECT TO ALL THE
FINDINGS AN ACCURATE TITLE SEARCH
WOULD REVEAL. NO TITLE FURNISHED
TO THIS SURVEYOR.
6.
PHYSI
CALLY EVIDENT UTILITIES ARE
SHOWN BUT NOT WARRANTED.
CONTRACTOR SHALL CONTACT 811, 72
HOURS PRIOR TO ANY EXCA V ATION
AS PRESCRIBE BY STATE LAW.
ON THE FEMA FIS RATE MAP NO.
471187C0385G DATED 12-20-2024 &
8. THIS PROPERTY IS SHOWN AS ZONE "X"
3. TAX MAP 140, PARCEL 014.14
DODD FAMILY REVOCABLE LIVING TRUST
8491 TALIAFERRO ROAD
EAGLEVILLE, TN 37060
9. THIS PROPERTY IS ZONED RD-5
10. THE MINIMUM REQUIRED BUILDING
SETBACKS: FRONT=100'
SIDE=25', REAR=50'.
7. THIS IS A CATEGORY IV SURVEY AS DEFINED
IN RUL 0820-03-.05 OF THE RULES OF THE TN
BOARD OF EXAMINERS FOR LAND SURVEYORS.
WE USED CARLSON BRx7 MULTI-FREQUECY GNSS
UNITS. THIS IS A REAL TIME KINEMATICS (RTK)
SURVEY WITH BASE-ROVER MODE UTILIZING
1983 EPOCH 2025.063 TN. STATE PLANE COORDINATES
GEOID 2018 AND A COMBINED GRID TO GROUND
SCALE FACTOR OF 1.0000123615. CONTROL W AS
ESTABLISHED USING THE TDOT NETWORK AND
NO FIXED STATIONS WERE USED.
THE PURPOSE OF THIS PLAT IS TO OBTAIN APPROV AL FOR
RELOCATION OF THE ACCESS EASEMENT ON PARCEL 14.14 TO
ALLOW FOR APPROV AL OF A RESERVE SEPTIC FIELD
NOTE: THIS PROPERTY HAS BEEN REVIEWD FOR THE EXISTENCE
OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT
WOULD REQUIRE WATERWAY NATURAL AREAS AS DESCRIBED
IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER
MANAGEMENT REGULATIONS HA VE BEEN LOCATED AS SHOWN.
NOTE: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF
STEEP SLOPES, HILLTOPS, AND RIDGETOPS, SLIPPAGE SOILS,
AND KARST FEATURES. THERE ARE MODERATLY STEEP SLOPES
WITHIN THE BUILDING ENVELOPE. NO WETLANDS ARE VISIBLE
NOTE: THE EASEMENT FOR THE COMMON DRIVEW AY SHALL
RUN WITH THE LAND AND SHALL BE BINDING ON AND SHALL
INURE TO THE BENEFIT OF ALL PARTIES FOR WHOSE BENEFIT
THE COMMON DRIVEWAY EXISTS, THEIR HEIRS, SUCCESSORS
AND ASSIGNS.
GEOTHERMAL WELL CONSTRUCTION STANDARDS
FOR CLOSED LOOP GEOTHERMAN BOREHOLES
SOURCE OF STRUCTURE M
INIMUM
DISTANCE
SEWER LINES 10 FEET
SEPTIC TANKS 25 FE
ET
SPRINGS 100 FEET
SEPTIC DRAIN FIELDS 2
5 FEET
WATER WELLS 100 FEET
HOUSE
TO SEPTIC CONNECTION 10 FEET
HOUSE TO SEWER CONNECTION 10 FEET
CURTAIN DRAIN TABLE A B C D E F G H
GROUND ELEV. 785.3 792.4 794.0 794.0 795.0 793.6 792.0 785.6
I
NVERT ELEV . 785.3 789.4 789.7 791.0 792.0 790.6 789.0 785.6
DRAIN DEPTH 0 3.0 4.3 3.0 3 3 3 0
MINOR LARGE LOT SUBDIVISION
JUNE 15, 2026
471187C0395G DATED 12-20-2024
11. THERE WILL BE NO NEW ACCESS
TO TALIAFERRO ROAD FROM PARCEL 14.14
12. E
NGINEERED SITE PLANS ARE REQUIRED
FOR BUILDING PERMIT APPLICATIONS IN
MODERATELY STEEP SLOPE AREAS.
13. ANY NEW CONSTRUCTION WILL REQUIRE
SPRINKLER SYSTEMS BE ADDED TO THE HOME.
TYPICAL W
OODEN FENCE
4' IN HEIGHT, W
ITH THREE
RAILS
OR PRESENT AT THE TIME OF THE SURVEY .
x x x FENCE
PRIV ATE DRIVEWAY NOTATION
PRIV ATE DRIVEWAY NOTATION
This is a privae driveway and is not a public road. Williamson County does not have responsibility for
building or maintaining the private driveway. The Williamson County Highway Commission may, at itsdiscretion, agree to accept this private driveway as a pub lic road and into thte County Highway System if allproperty owners agree to (1) petition the Highway Commission for a public road and (2) build or pay for
upgrading the private driveway to County Specifications in effect at the time of the request.
_____________________________, 20____
Date
_____________________________________ ______________________________________
Connty Engineer County Road Superintendent
By signing below, the property owner(s) of all lots within the bounds of this plat acknowledge awareness
of the above Private Driveway Notation and understands Williamson County does not have responsibility
for building or maintaining the private driveway.________________________________ _______________________________________
Owner Signature(s)
Tax Map & Parcel number of Lot
______________________________ _____________________________
Date Deed Book & Page
14. A V ARIANCE ON DRIVEWAY WIDTH WAS
APPROVED BY WILLIAMSON CO. PLANNING
COMMISSION ON JUNE 11, 2026
ATTACHMENT 23-1B
ATTACHMENT 23-2
MINUTES OF THE
WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION
MEETING OF AUGUST 13, 2026
MEMBERS PRESENT
Brian Clifford
Don Crohan
Lee Kennedy
Steve Lane
Jessica Lucyshyn
Keith McCord
Sammie McCoy
STAFF PRESENT
Michael Matteson, Community Development
Director
Aaron V. Holmes, Planning Director
Floyd Heflin, County Engineer
Michael Scott, Ass’t to County Engineer
Kristi Ransom, County Attorney
Joe James, Planning Coordinator
Lincoln Sweet, Senior Planner
Charlie Waldrop, Planning Technician
Michelle Mullins, Planning Assistant
The Williamson County Regional Planning Commission met in regular session Thursday,
August 13, 2026, at 5:47 p.m. in the Auditorium of the Williamson County Administrative
Complex. Commissioners Bailey, Baldree, Hatcher, Richter, and Sanders were unable to
attend.
Chairman McCoy called the meeting to order and took Roll Call. A quorum was present.
Chairman McCoy asked if there were any announcements.
Mr. Holmes announced the following:
• Revised reports for Item 13 to correct a driveway reference, Item 15 reflecting
open space requirements, and Items 16 and 18 where the applicant has requested
deferral to the October meeting;
• Item 9, Terravista, Section 2, Maintenance Bond for the Wastewater Collection
System appeared on the Consent Agenda in the packets. However, Staff has
removed it from the Consent Agenda for separate consideration;
• Revised Consent Agendas reflecting removal of Item 9, and the deferral of Items
16 and 18 to the October meeting;
• Items 12, 16, 17, 18, and 19 are on the Consent Agenda for Deferral ;
• Additional Attachments 15 -3 and 15-4 have been added to the revised report for
Item 15; and
• Request for a Non-Agenda Item regarding consideration of request related to
authority to approve Amendments to Hardeman Springs HOA documents. A Report
was provided to Commissioners for review.
Chairman McCoy asked for a motion to add the Non-Agenda Item requesting to approve
Amendments to Hardeman Springs HOA documents to the Agenda.
Commissioner Kennedy made a motion to add this Non-Agenda Item to the Agenda.
The motion was seconded by Commissioner Lucyshyn. The motion was unanimously
approved.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 2 of 14
Chairman McCoy opened the floor to Public Comments.
PUBLIC COMMENTS:
Gerald Wigger, Counsel for the Terravista Homeowner’s Association (HOA), noted that at
of the February 2026 Planning Commission Meeting, County Engineer, Floyd Heflin, stated
that the rainy season was approaching and the Applicant’s Engineer felt that they could
stabilize the Wastewater Road. Staff also stated that they would hold the Maintenance
Bonds until the project had been completed as there had been multiple months to
complete the issues, which included ponds that didn’t drain and Staff had advised there
were multiple deviations from the approved plans. It was stated that if the project wasn’t
completed by summer, that Staff would discuss calling the bonds. Mr. Wigger stated that
there are major Roads, Drainage and Erosion Control (RDE) works in progress, but they
are not near completion. There is significant damage to the common area, multiple
broken concrete curbs, parking aprons, and fences, as well as the Stanley cul-de-sac is
collecting all of the road deterioration runoff. We are at the end of the summer and the
project is still nowhere near completion. He requests that per Mr. Heflin’s previous
statement, the bonds be called.
Chairman McCoy closed the Public Comments.
C
ONSIDERATION OF JULY 9, 2026 MINUTES:
Chairman McCoy asked if there were comments or questions on the Minutes. Hearing
none, he asked for a motion.
Commissioner Crohan made a motion to approve the July 9, 2026 Minutes. The motion
was seconded by Commissioner Clifford. The motion was unanimously approved.
CONSENT AGENDA:
Chairman McCoy mentioned that Item 9 was removed for separate discussion, and asked
if there were any additional Items that needed to be discussed separately on the Consent
Agenda.
Hearing none, he asked for a motion to accept the Consent Agenda as a whole.
Commissioner C rohan made a motion to approve the Consent Agenda per Staff
recommendations. Commissioner Lane seconded the motion. The motion was
unanimously approved.
BONDS:
3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro
Road. - $67,950
Recommendation: Extend in the current amount for a period of six (6) months.
4. King’s Chapel, Section 12 - Maintenance Bond for Wastewater Collection System
located off Murfreesboro Road. - $21,000
Recommendation: Release the bond.
5. Lookaway Farms, Section 3 – Maintenance Bond for Wastewater Collection System
located off Clovercroft Road. - $15,000
Recommendation: Release the bond.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 3 of 14
6. Reeds Vale, Section 1 – Maintenance Bond for Wastewater Collection System located
off Lampkins Bridge Road. - $96,600
Recommendation: Release the bond.
7. Starnes Creek, Section 2 – Maintenance Bond for Wastewater Collection System
located off Meeks Road. - $12,900
Recommendation: Release the bond.
8. Starnes Creek Wastewater Area – Maintenance Bond for Wastewater Treatment and
Disposal System located off Meeks Road. - $120,700
Recommendation: Release the bond.
9. Terravista, Section 2 - Maintenance Bond for Wastewater Collection System located
off Long Lane. – NOT ON CONSENT
10. The Grove, Section 14 – Maintenance Bond or Roads, Drainage and Erosion Control
located off Arno Road. - $425,000
Recommendation: Release the bond.
DEFERRAL ITEMS:
ITEM 12
PRELIMINARY PLAT REV IEW FOR LOFTY MEADOW ESTATES SUBDIVISION ,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GRO VE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
ITEM 16
SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND
DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRE S
LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007).
At this time, the applicant is requesting deferral to the October 2026 Planning Commission
Meeting in order to allow the applicant more time to address Staff comments. Staff
concurs with this request.
ITEM 17
SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG
WRITER’S CABINS, ON 2.5 ACRES LOCATED OF F CLUB VIEW DRIVE IN THE
5TH VOTING DISTRICT (5-2026-006).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 4 of 14
ITEM 18
CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON
108.16 ACRES LOCATED OFF HALEY LANE IN T HE 5TH VOTING DISTRICT (1 -
2026-203).
At this time, the applicant is requesting deferral to the October 2026 Planning Commission
Meeting in order to allow the appli cant more time to address Staff comments. Staff
concurs with this request.
ITEM 19
CONCEPT PLAN REVIEW FOR 1600 RIVER LANDI NG DRIVE SUBDIVISION ,
CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING D RIVE
IN THE 9TH VOTING DISTRICT (1-2026-204).
At this time, the applicant is requesting deferral to the September 2026 Planning
Commission Meeting in order to allow the applicant more time to address Staff comments.
Staff concurs with this request.
FINAL PLATS:
ITEM 22
FINAL PLAT REVIEW FO R THE GROVE SUBDIVISION, S ECTION 18,
CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND
VOTING DISTRICT (1-2026-414).
Final Plat is in order, and Staff recommends approval with the following conditions:
1. Establishment of a maintenance bond for water improvements in favor of
Milcrofton Utility District in the amount of $44,332.30;
2. Per the recommendation of the County’s Wastewater Consultant, establishment of
a performance bond for the wastewater collection system in the amount of
$137,924.71;
3. Execution of performance agreements for the above referenced sureties;
4. The approved HOA documents must be recorded concurrently with the recording
of the Final Plat;
5. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
6. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and recording
of the plat.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 5 of 14
ITEM 9
TERRAVISTA, SECTION 2 - MAINTENANCE BOND FOR WASTEWATER
COLLECTION SYSTEM
Mr. Holmes advised that the bond has satisfied the requisite two (2) year maintenance
period. Therefore, Staff recommended releasing the bond.
Chairman McCoy asked for confirmation that there are still other bonds for this project
that are open.
Mr. Holmes stated that was correct.
Chairman McCoy asked if there were any questions on this Item.
Commissioner Crohan asked if Staff was satisfied that the work had been completed
sufficiently.
Mr. Holmes advised that Staff is satisfied.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner Crohan made a motion to approve per Staff recommendation.
Commissioner Clifford seconded the motion. The motion was unanimously approved.
OLD BUSINESS:
ITEM 23
ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVIST A
SUBDIVISION, SECTIONS 1 AND 2.
Brent Thoeny, with TruLand Consultants, represented the applicant, The Jones Company.
He advised that he had supplied the requested chart to the Commission, regarding the
work timeline for the remaining items that are being worked on. He stated that since the
July meeting, the gabion baskets have been added, but the pond bottoms are still trying
to get them graded since it has been too wet due to the rain. To his understanding the
County has reviewed the Site Plan for the mail kiosk. In Phase One (1) it is mainly all just
the pond bottoms that they are working on and the access points where the workers are
coming in and out will have to be resided once they have finished. I n Phase Two (2),
pond five (5) is also holding some water in the flume and an area of water retention
outside of the flume that is about fifteen (15) feet x fifteen (15) feet, which will need to
be addressed. The storm drains will be videoed and anywhere that needs to be flushed ,
once the grade work is complete, will be done by a vendor that will be on standby. They
are proposing to put a riprap up the wastewater road to try to stabilize that and the
asphalt vendor cut the curve and should not have, so they will replace the curb.
Chairman McCoy asked if the wastewater road has been paved.
Mr. Theony confirmed that it had been paved, but that due to the amount of rain recently,
the water is coming down the hill hitting the edge of the pavement causing it to wash
down into the cul-de-sac. They are proposing a three (3) foot ditch running up the road
on both sides with riprap and fabric to slow the water down .
Chairman McCoy asked if the ditches will turn away from the road.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 6 of 14
Mr. Theony stated they will continue to run into the road, because it is on a hillside, but
they believe it is an issue of the speed of the water as opposed to the direction.
Chairman McCoy asked if the cul-de-sac is being cleaned of the debris.
Mr. Theony stated it had been cleaned. However, there was a little bit of debris that he
has asked the workers to remove.
Chairman McCoy asked if the cul-de-sac has been topped and finished.
Mr. Theony confirmed that it has been topped.
Chairman McCoy asked if there were any questions for Mr. Theony.
Commissioner Clifford asked what their level of confidence was, so that they could assure
the Commission that this project was a priority .
Mr. Theony advised that for the last eight (8) weeks, barring the weather, they have been
onsite working almost every day.
Commissioner Clifford mentioned the pictures that had been submitted of the work that
hadn’t been completed. He asked how confident Mr. Theony was that once Phase One
(1) and Phase Two (2) had been completed, these types of issues were not going to
continue to re-occur.
Mr. Theony stated that in regard to the pictures, some of those pictures show how much
it had recently rained, and that it currently looks as it did two (2) weeks ago, prior to the
rain. He advised that he is fairly confident that there s houldn’t continue to be issues,
unless there is consistent, heavy rainfall.
Commissioner Clifford asked if Staff feels that the applicant is on track with the proposed
timeline.
Mr. Scott advised that he can’t say for sure when they will be finished, but that they are
making progress, and the recent rains have made it difficult. They are trying to clean, re-
stabilize, and re-grade. There is some erosion around the wastewater road that is being
addressed as well. He believes they should continue working o n the project.
Commissioner Lucyshyn stated that the schedule they provided shows a duration of a
task, but when the task ends, it shows as ND, or “Not Done” on the schedule. She didn’t
understand the value of showing the dates if the work was still not d one.
Mr. Theony advised that below that it shows where it has been extended, because they
are related to walks and checks. The only physical work out there at this point is the
edges of the wastewater road, the bottom of the ponds and the storm pipe sewer video
once the grading is done. He believes this should only take about two (2) weeks as long
as there is no additional rainfall.
Chairman McCoy made the comment that whatever work needs to be completed, should
be done so in a way that there doesn’t continue to be issues that require long -term
maintenance, and be left up to the Homeowner’s Association (HOA) to handle.
Commissioner Crohan stated that he does not recall a project that has been this much of
a problem while serving as a commissioner, and he feels that if this hasn’t been completed
by the September meeting, the Commissioner should consider calling the bond and
finding someone else to come in and finish the work .
Williamson County Planning Commission
Meeting of August 13, 2026
Page 7 of 14
Chairman McCoy asked if there were any further questions. Hearing none, he continued
to the next Item.
ITEM 12
PRELIMINARY PLAT REV IEW FOR LOFTY MEADOW ESTATES SUBDIVISION ,
CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GRO VE
ROAD IN THE 2ND VOTING DISTRICT (1-2025-310).
This Item is on the Consent Agenda for Deferral.
ITEM 13
PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY
LLE SUBDIVISION, CON TAINING 1 LOT ON 20. 33 ACRES LOCATED OFF
TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-301).
Mr. Sweet reviewed the background (see Staff Report) recommending approval of this
Preliminary Plat with the following conditions:
1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a
Land Disturbance Permit, if there is 1-acre or more of disturbance;
2. Prior to submittal of the Final Plat, provide a letter from the water provider either
stating the water lines are installed and functioning or listing a Performance Bond
amount for water improvements;
3. A Land Disturbance Permit must be obtained for the overall development;
4. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be
complete, consistent with County regulations;
5. Satisfaction of Section 3.05 of the Subdiv ision Regulations, as it pertains to fire
sprinkler system requirements; and
6. Affixing a note to the Plat noting that all structures, including accessory structures,
shall be separated by a minimum of 200 feet.
Chairman McCoy asked if there were any questions.
Commissioner Crohan advised that he understood Williamson County Fire and Rescue
declined a variance for this, because they didn’t feel the driveway was capable of
handling the equipment. He asked if their position had changed.
Mr. Holmes stated that Staff had not received any documentation from Williamson
County Fire and Rescue.
Commissioner Crohan advised that he had documentation.
Mr. Holmes confirmed that the document Mr. Crohan was referring to was provided by
the applicant’s legal counsel, and it was a drafted copy that Staff did not receive for this
particular Item.
Commissioner Crohan advised that he would find it hard to approve a variance when
there is as question as to whether fire equipment could acces s the property.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 8 of 14
Chairman McCoy asked if the applicant was present.
Doug Berry, with Miller Martin Law Firm represented the applicants, Mr. and Mrs.
Russell, and he stated that he had provided a letter on this issue and would be happy
to answer any questions. In response to Commissioner Crohan’s statement, there is an
alternative for the variance, which is to have all structures on the property sprinkled
with a separation distance of two hundred (200) feet between them all, and the
applicant has agreed to do this. This is also a hardship to consider for one owner to
financially cover the improvement of an entire easement that is also serving several
other properties. To do this would additionally require the applicant to have to obtain
easement rights from said property owners, not to mention that this was a situation the
applicant moved into and did not create as the easement was created twenty-five (25)
years ago, before subdivision jurisdiction applied to divisions of land . Therefore, they
feel that the option to sprinkle the buildings and maintain the two hundred (200) foot
distance should be adequate.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner McCord made a motion to approve per Staff recommendation.
Commissioner Kennedy seconded the motion. Six (6) in favor, o ne (1) opposed , with
Commissioner Crohan voting no. Motion passed.
SITE PLANS:
ITEM 14
SITE PLAN REVIEW FOR CREWS RUNWAY, ON 1, 137.13 ACRES LOCATED OFF
BOY SCOUT ROAD IN THE 1ST VOTING DISTRICT (5 -2026-004).
Mr. Holmes reviewed the background (see Staff Report) recommending approval of this
Site Plan with the conditions that a Consolidation Deed and Land Disturbance Permit be
obtained.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner Clifford made a motion to approve per Staff recommendation.
Commissioner Lane seconded the motion. The motion was unanimously approved.
ITEM 15
SITE PLAN REVIEW FOR WYELEA FARMS – THE STABLES, ON 53.70 AC RES
LOCATED OFF DEL RIO PIKE IN THE 9TH VOTING DISTRICT (5 -2026-005).
Mr. Waldrop reviewed the background (see Staff Report) recommending approval of this
Site Plan with the following conditions:
1. Per the recommendation of the County’s Wastewater Consultant, the posting of a
Performance Bond for the Collection System in the amount of $242,000; and
2. Final Plats of the areas to be transferred for both the Stables and Wyelea Farms
Common Area, as depicted in Attachments 15- 3 and 15-4, shall be recorded before
issuance of Building Permits for the Stables; and
Williamson County Planning Commission
Meeting of August 13, 2026
Page 9 of 14
3. Execution of a Performance Agreement for the above referenced sureties.
Chairman McCoy asked if there were any questions. Hearing none, he asked for a
motion.
Commissioner Clifford made a motion to approve per Staff recommendation.
Commissioner Kennedy seconded the motion. The motion was unanimously approved.
ITEM 16
SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AN D
DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRES
LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007).
This Item is on the Consent Agenda for Deferral.
ITEM 17
SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG
WRITER’S CABINS, ON 2.5 ACRES LOCATED OF F CLUB VIEW DRIVE IN THE
5TH VOTING DISTRICT (5-2026-006).
This Item is on the Consent Agenda for Deferral.
CONCEPT PLANS:
ITEM 18
CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON
108.16 ACRES LOCATED OFF HALEY LANE IN T HE 5TH VOTING DISTRICT (1 -
2026-203).
This Item is on the Consent Agenda for Deferral.
ITEM 19
CONCEPT PLAN REVIEW FOR 1600 RIVER LANDI NG DRIVE SUBDIVISION ,
CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING D RIVE
IN THE 9TH VOTING DISTRICT (1-2026-204).
This Item is on the Consent Agenda for Deferral.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 10 of 14
PRELIMINARY PLATS:
ITEM 20
PRELIMINARY PLAT REV IEW FOR THE VILLAGES AT TRIUNE WEST
SUBDIVISION (REVISED ), CONTAINING 98 SINGLE FAMILY LOTS, 214
TOWNHOME LOTS, AND T EN (10) NON-RESIDENTIAL LOTS ON 157.79 A CRES
LOCATED OFF HORTON H IGHWAY IN THE 5TH VO TING DISTRICT (1 -2026-
309).
Mr. James reviewed the background (see Staff Report) recommending approval of this
Preliminary Plat with the following conditions:
1. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 55
th lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4
and 20-5) shall be completed to the satisfaction of the Tennessee Department
of Transportation;
2. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 55th lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4
and 20 -5) shall be completed to the satisfaction of the Williamson County
Highway Superintendent;
3. As specified by t he County’s Traffic Consultant, the i nstallation of traffic signals
and construction of the right turn deceleration lanes on Horton Highway at the I-
840 Eastbound and Westbound Ramps shall be completed/constructed prior to
the issuance of building permits for any of the non-residential land uses;
4. The residential lots shall not be permitted to take access to Malachi Lane until the
traffic signal at the intersection of Horton Highway and Malachi Lane has been
installed and is operational;
5. Prior to the submi ttal of the first Final Plat, the required Zoning Certificate for
the wastewater treatment and disposal system shall be submitted, and all
conditions associated with the wastewater site plan approval must be satisfied;
6. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must address the greenway easement, the maintenance and
operation of the private roads and gate that meet the standards, and
requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents
must be submitted with the Final Plat, and the approved HOA documents must
be recorded concurrently with the recording of the Final Plat;
7. A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of the Zoning
Ordinance must be met;
8. Prior to the submittal of any Final Plat in which a greenway is located, the 12 -
foot-wide paved multi-modal greenway trail should be constructed;
9. Establishment of a performance bond for roads, drainage and erosion control;
10. Establishment of a performance bond for water improvements in favor of
Nolensville/College Grove Utility District;
11. Establishment of a performance bond for the wastewater collection system;
Williamson County Planning Commission
Meeting of August 13, 2026
Page 11 of 14
12. Submission of landscaping plans and establishment of a performance bond for
landscaping improvements;
13. Execution of Performance Agreements for the above -referenced sureties;
14. Execution of a Stormwater Maintenance Agre ement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
15. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane Coordinate System prior to signature and
recording of the plat.
Chairman McCoy asked if there were any questions.
Commissioner Crohan asked why there is such a large change from the twenty -fifth
(25th) to fifty-fourth (54th) lot before the traffic signal is put in.
County Traffic Consultant, Kayla Ferguson advised that the applicant is going through
the design process for the signal at Malachi Lane and Horton Highway, and that they
may have had some difficulty with one of the property owners when obtaining
easements. Therefore, their design approval from the Tennessee Department of
Transportation (TDOT) took longer than expected. The signal is still on track to be
completed by December, before any lots would be constructed.
Chase Kerr, Crunk Engineering, represent ing the applicant, stated he could help explain
the changes that are being made. He advised that this is also concurrent with Item 23,
which is the East side. Though they are two (2) separate Items, combined they total
eighty-four (84) lots. There was a lot of back and forth while trying to gain easement
access between property owners at the intersection of Horton Highway and Malachi
Lane, which caused a delay in the traffic signal design. They have obtained approval
from TDOT, and the permit should be received by the following week, which is when
they expect to start construction. The signal is expected to be installed before the end
of the year and before any homes are under construction. This is to keep the project
from being stalled.
Commissioner Crohan asked for confirmation that they do feel the construction of the
traffic signal would be complete by December, regardless of lot sales.
Mr. Kerr advised that he did, and that there was also a long lead time on the traffic
signal poles, because they are specially constructed. However, they do anticipate the
intersection to be constructed and the traffic signals installed by December.
Commissioner Crohan asked if it could be put into the Meeting Minutes that the traffic
signal would be installed by the fif ty-fourth (54
th) lot or December, whichever comes
first.
Mr. Kerr stated that while he can’t predict the construction timeline, they do anticipate
the signal being installed and operational by the end of the year.
Commissioner Lucyshyn mentioned that the timeline is referring to when the Final Plat
is submitted. She asked how many lots have been submitted in the Final Plat as of now.
Mr. Kerr advised they have not submitted the Final Plat yet and they anticipate
submitting it for September’s Meeting.
Commissioner Lucyshyn asked Ms. Ferguson how they would follow th rough with there
being no residential lots taking access to Malachi Lane until the traffic signal is installed.
Williamson County Planning Commission
Meeting of August 13, 2026
Page 12 of 14
Ms. Ferguson stated that she isn’t sure how access to roadways is governed by the
County, but that they would be in the process of constructing both accesses, and
therefore, she would assume that any of the internal roadway connections that would
feed those lots would not be allowed to tie in. No traffic will be allowed until the signal
is installed and active.
Commissioner Lucyshyn asked if while this is happening, the only access to the site
would be from Murfreesboro Road.
Mr. Kerr confirmed that is correct.
Chairman McCoy asked for confirmation that when a Final Plat is submitted, does that
mean you have started building.
Mr. Kerr advised that at that point they have not started building.
Chairman McCoy asked if there were any further questions . Hearing none, he asked for
a motion.
Commissioner Clifford made a motion to approve per Staff recommendation.
Commissioner Lane seconded the motion. The motion was unanimously approved.
ITEM 21
PRELIMINARY PLAT REV IEW FOR THE VILLAGES AT TRIUNE EAST
SUBDIVISION (REVISED ), CONTAINING 59 SINGLE FAMILY LOTS, 63
TOWNHOME LOTS, AND T HREE (3) NON-RESIDENTIAL LOTS ON 63.78 A CRES
LOCATED OFF HORTON H IGHWAY IN THE 5TH VO TING DISTRICT (1 -2026-
310).
Mr. James reviewed the background (see Staff Report) reco mmending approval of this
Preliminary Plat with the following conditions:
1. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 31
st lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 21 -4
and 21-5) shall be completed to the satisfaction of the Tennessee Department
of Transportation;
2. Except as noted in Number 3 below, prior to the submittal of the Final Plat
containing the 31
st lot, all off-site roadway improvements associated with Phases
1 and 2 as specified by the County’s Traffic Consultant (See Attachments 21 -4
and 21 -5) shall be completed to the satisfaction of the Williamson County
Highway Superintendent;
3. As specified by t he County’s Traffic Consultant, the i nstallation of traffic signals
and construction of the right turn deceleration lanes on Horton Highway at the I-
840 Eastbound and Westbound Ramps shall be completed/constructed prior to
the issuance of building permits for any of the non-residential land uses;
4. The residential lots shall not be permitted to take access to Malachi Lane until the
traffic signal at the intersection of Horton Highway and Malachi Lane has been
installed and is operational;
5. At eighty -five percent (85%) build -out, Malachi Lane shall be repaved in its
entirety, as required by the Williamson County Highway Department;
Williamson County Planning Commission
Meeting of August 13, 2026
Page 13 of 14
6. Prior to the submittal of the first Final Plat, the required Zoning Certificate for
the wastewater treatment and disposal syste m shall be submitted, and all
conditions associated with the wastewater site plan approval must be satisfied;
7. Prior to consideration of Final Plat approval, the applicant shall submit HOA
documents for review and approval by the County Attorney’s office. The HOA
documents must address the greenway easement, the maintenance and
operation of the private roads and gate that meet the standards, and
requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents
must be submitted with the Final Pl at, and the approved HOA documents must
be recorded concurrently with the recording of the Final Plat;
8. A permit for the security gate will need to be obtained prior to its installation,
and all requirements for such gates as outlined in Section 17.11 of th e Zoning
Ordinance must be met;
9. Prior to the submittal of any Final Plat in which a greenway is located, the 12 -
foot-wide paved multi-modal greenway trail should be constructed;
10. Establishment of a performance bond for roads, drainage and erosion control;
11. Establishment of a performance bond for water improvements in favor of
Nolensville/College Grove Utility District;
12. Establishment of a performance bond for the wastewater collection system;
13. Submission of landscaping plans and establishment of a performance b ond for
landscaping improvements;
14. Execution of Performance Agreements for the above -referenced sureties;
15. Execution of a Stormwater Maintenance Agreement and submission of an
Operation and Maintenance Plan for stormwater improvements; and
16. Submission of the approved Final Plat in .dwg format on recordable media based
on the Tennessee State Plane
Text truncated. Open the original for the full document.
Source: Williamson County website. First collected Oct 18, 2026.