RecordWell Data

Packet

Williamson County · Williamson County · meeting of Aug 13, 2026 · Agenda packets

Open the original document More from Williamson County

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

August 2026 Planning Commission Agenda PC PACKET 8-13-2026 - 1 OF 4.PDF PC PACKET 8-13-2026 - 2 OF 4.PDF PC PACKET 8-13-2026 - 3 OF 4.PDF PC PACKET 8-13-2026 - 4 OF 4.PDF AUGUST 2026 PC MINUTES 02 AUGUST 2026 PC MINUTES.PDF 1. Documents: 1.I. Documents: ORDER OF BUSINESS WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION 1. Call to order 2. Roll Call 3. Announcements 4. Public Comments 5. Consideration of Minutes 6. Consideration of Consent Agenda 7. Presentation of Agenda Items for Discussion and Action 8. Other Business AGENDA WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION Williamson County Administrative Complex August 13, 2026 at 5:30 p.m. PUBLIC COMMENTS: Public comment is permitted on Agenda items – sign-in prior to the meeting is required. MINUTES: 1. Approval of July 9, 2026 Minutes CONSENT AGENDA: 2. Consent Agenda BONDS: 3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro Road. 4. King’s Chapel, Section 12 - Maintenance for Wastewater Collection System located off Murfreesboro Road. 5. Lookaway Farms , Section 3 – Maintenance Bond for Wastewater Collection System located off Clovercroft Road. 6. Reeds Vale, Section 1 - Maintenance Bond for Wastewater Collection System located off Lampkins Bridge Road. 7. Starnes Creek, Section 2 - Maintenance Bond for Wastewater Collection System located off Meeks Road. 8. Starnes Creek Wastewater System – Maintenance Bond for Wastewater Treatment and Disposal System located off Meeks Road. 9. Terravista, Section 2 – Maintenance Bond for Wastewater Collection System located off Long Lane. 10. The Grove, Section 14 – Maintenance Bond for Roads, Drainage and Erosion Control located off Cox Road. OLD BUSINESS: 11. Terravista Roads, Drainage, and Erosion Control Bond Update 12. Preliminary Plat Review for Lofty Meadow Estates Subdivision, containing 5 lots on 32.3 acres located off Arno -College Grove Road in the 2 nd Voting District (1-2025- 310). 13. Preliminary Plat Review for Lot 1 of the Larry U. Turner Property LLE Subdivision, containing 1 lot on 20.33 acres located off Taliaferro Road in the 5 th Voting District (1-2026-301). SITE PLANS: 14. Site Plan Review for Crews Runway, on 1,137.13 acres located off Boy Scout Road in the 1st Voting District (5-2026-004). 15. Site Plan Review for Wyelea Farms – The Stables, on 53.70 acres located off Del Rio Pike in the 9th Voting District (5-2026-005). 16. Site Plan Review for Non -Traditional Wastewater Treatment and Disposal System Review for Brynn Subdivision, on 108.12 acres located off Haley Lane in the 5th Voting District (5-2026-007). 17. Site Plan Review for Troubadour Golf and Field Club – Song Writer’s Cabins, on 2.5 acres located off Club View Drive in the 5 th Voting District (5-2026-006). CONCEPT PLANS: 18. Concept Plan Review for Brynn Subdivision, containing 21 lot on 108.16 acres located off Haley Lane in the 5th Voting District (1-2026-203). 19. Concept Plan Review for 1600 River Landing Drive, containing 2 lots on 22.76 acres located off River Landing Drive in the 9 th Voting District (1-2026-204). PRELIMINARY PLATS: 20. Preliminary Plat Review for The Villages at Triune West Subdivision, (Revised), containing 98 Single-Family Lots, 214 Townhome Lots, and Ten (10) Non-Residential Lots on 157.79 acres located off Horton Highway in the 5 th Voting District (1-2026- 309). 21. Preliminary Plat Review for The Villages at Triune East Subdivision (Revised), containing 59 Single-Family Lots, 63 Townhome Lots, and Three (3) Non-Residential Lots on 63.78 acres located off Horton Highway in the 5 th Voting District (1-2026- 310). FINAL PLATS: 22. Final Plat Review for The Grove Subdivision, Section 18, containing 1 1 lots on 9.02 acres located off Arno Road in the 2nd Voting District (1-2026-414). 23. Final Plat Review for Dodd Family Revocable Living Trust Subdivision, containing 1 lot on 32.12 acres located off Taliaferro Road in the 5 th Voting District (1-2026-415). MINUTES OF THE WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION MEETING OF JULY 9, 2026 MEMBERS PRESENT David Bailey Brian Clifford Don Crohan Lee Kennedy Steve Lane Jessica Lucyshyn Keith McCord Sammie McCoy Eddie Sanders STAFF PRESENT Michael Matteson, Community Development Director Aaron V. Holmes, Planning Director Floyd Heflin, County Engineer Michael Scott, Ass’t to County Engineer Kristi Ransom, County Attorney Joe James, Planning Coordinator Lincoln Sweet, Senior Planner Charlie Waldrop, Planning Technician Michelle Mullins, Planning Assistant The Williamson County Regional Planning Commission met in regular session Thursday, July 9, 2026, at 5:30 p.m. in the Auditorium of the Williamson County Administrative Complex. Commissioners Baldree, Hatcher, and Richter were unable to attend. Chairman McCoy called the meeting to order and took Roll Call. A quorum was present. Chairman McCoy asked if there were any announcements. Mr. Holmes announced the following: • Items 36 is on the Consent Agenda for Deferral ; • Item 35 has been Withdrawn; and • Request for Non -Agenda Item, Pine Creek, Section 2, Maintenance Bond for Wastewater Collection System . Reports were provided to all Commissioners for review. Chairman McCoy asked for a motion to add Pine Creek, Section 2, Maintenance Bond for Wastewater Collection System to the Agenda. Commissioner Crohan made a motion to add Pine Creek, Section 2 to the Agenda. The motion was seconded by Commissioner Sanders. The motion was unanimously approved. Chairman McCoy opened the floor to Public Comments. PUBLIC COMMENTS: Gerald Wigger, Counsel for the Terravista Homeowner’s Association (HOA), stated that despite the orders of the Planning Commission, Jones Company has not fulfilled their obligations to the association. One specific issue is the irrigation system. Per the Jones Company’s attorney, they will not agree to pay for the repair or replacement of the irrigation system. Mr. Wigger requested on behalf of the Terravista HOA, that any release of bonds be denied. Chairman McCoy closed the Public Comments. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 2 of 9 CONSIDERATION OF JUNE 11, 2026 MINUTES: Chairman McCoy asked if there were comments or questions on the Minutes. Hearing none, he asked for a motion. Commissioner Clifford made a motion to approve the June 11, 2026 Minutes. The motion was seconded by Commissioner Bailey. The motion was unanimously approved. CONSENT AGENDA: Chairman McCoy asked if there were any Items that needed to be discussed separately on the Consent Agenda. Hearing none, he asked for a motion to accept the Consent Agenda as a whole. Commissioner C rohan made a motion to approve the Consent Agenda per Staff recommendations. Commissioner Lane seconded the motion. The motion was unanimously approved. BONDS: 3. Arrington Ridge, Section 2 – Performance Bond for Roads, Drainage and Erosion Control located off Cox Road. - $383,000 Recommendation: Extend in the current amount for a period of one (1) year. 4. Brightstone Campus – Performance Bond for Landscaping located off Columbia Avenue. - $145,750 Recommendation: Extend in the current amount for a period of one (1) year. 5. Brightstone Campus - Performance Bond for Wastewater Treatment and Disposal System located off Columbia Avenue. - $214,300 Recommendation: Extend in the current amount for a period of one (1) year. 6. Enclave at Dove Lake, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control located off Nolensville Road. - $357,000 Recommendation: Extend in the current amount for a period of one (1) year. 7. Hardeman Springs, Section 3 – Maintenance Bond for Roads, Drainage and Erosion Control located off Murfreesboro Road. - $150,000 Recommendation: Extend in the current amount for a period of six (6) months, or when Engineering staff has determined the improvements have been completed and the bond is ready for review by the Planning Commission, whichever comes first. 8. McDaniel Estates, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control located off McDaniel Road. - $450,000 Recommendation: Release the bond. 9. McDaniel Estates, Section 2 – Maintenance Bond for Roads, Drainage and Erosion Control located off McDaniel Road. - $330,000 Recommendation: Release the bond. 10. McDaniel Estates, Section 3 - Maintenance Bond for Roads, Drainage and Erosion Control located off McDaniel Road. - $200,000 Recommendation: Release the bond. 11. McDaniel Estates, Section 4 – Maintenance Bond for Roads, Drainage and Erosion Control located off McDaniel Road. - $260,000 Williamson County Planning Commission Meeting of Jul 9, 2026 Page 3 of 9 Recommendation: Release the bond. 12. McDaniel Farms, Section 1 - Maintenance Bond for Roads, Drainage and Erosion Control located off McDaniel Road. - $430,000 Recommendation: Release the bond. 13. Reeds Vale, Section 3 – Maintenance Bond for Water (Milcrofton) located off Lampkins Bridge Road. - $126,031.05 Recommendation: Release the bond. 14. Reeds Vale, Section 3 – Performance Bond for Roads, Drainage and Erosion Control located off Lampkins Bridge Road. - $1,350,000 Recommendation: Reduce to the amount of $1,012,000 and extend for a period of one (1) year. 15. Stephens Valley, Section 1 – Maintenance Bond for Roads, Drainage and Erosion Control located off Sneed Road. - $500,000 Recommendation: Release the bond. 16. Stephens Valley, Section 2 – Maintenance Bond for Roads, Drainage and Erosion Control located off Sneed. - $150,000 Recommendation: Release the bond. 17. The Grove, Section 13 – Maintenance Bond or Roads, Drainage and Erosion Control located off Arno Road. - $300,000 Recommendation: Release the bond. 18. Troubadour Golf and Club Farmstand – Performance Bond for Landscaping located off Cox Road. - $166,674 Recommendation: Reduce to the amount of $125,006 and extend for a period of one (1) year. 19. Troubadour, Section 8 – Maintenance Bond for Roads, Drainage and Erosion Control located off Cox Road. - $314,000 Recommendation: Extend in the current amount for a period of one (1) year. 20. Troubadour, Section 8 – Performance Bond for Wastewater Collection System located off Cox Road. - $87,250 Recommendation: Extend in the current amount for a period of one (1) year. 21. Troubadour, Section 10 – Performance Bond for Wastewater Collection System located off Cox Road. - $138,800 Recommendation: Extend in the current amount for a period of one (1) year. 22. Troubadour, Section 10 – Maintenance Bond for Roads, Drainage and Erosion Control located off Cox Road. - $422,000 Recommendation: Extend in the current amount for a period of one (1) year. 23. Troubadour, Section 12B – Performance Bond for Roads, Drainage and Erosion Control located off Patton Road. - $133,000 Recommendation: Extend in the current amount for a period of one (1) year. 24. Troubadour, Section 12B – Performance Bond for Wastewater Collection System located off Arno Road. - $16,000 Recommendation: Extend in the current amount for a per iod of one (1) year. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 4 of 9 25. Troubadour, Section 13A – Performance Bond for Roads, Drainage and Erosion Control located off Patton Road. - $1,500,000 Recommendation: Reduce to the amount of $1,150,000 and extend for a period of one (1) year. 26. Troubadour, Section 13B - Performance Bond for Wastewater Collection System located off Patton Road. - $329,000 Recommendation: Extend in the current amount for a period of one (1) year. 27. Troubadour, Section 13B – Performance Bond for Roads, Drainage and Erosion Control located off Patton Road. - $1,700,000 Recommendation: Reduce to the amount of $1,144,000 and extend for a period of one (1) year. 28. Troubadour, Section 14 – Performance Bond for Roads, Drainage and Erosion Control located off Patton Road. - $9,000 Recommendation: Extend in the current amount for a period of one (1) year. 29. Troubadour, Section 14 – Performance Bond for Wastewater Collection System located off Patton Road. - $8,000 Recommendation: Extend in the current amount for a period of one (1) year. 30. Troubadour, Section 15 – Maintenance Bond for Roads, Drainage and Erosion Control located off Cox Road. - $265,000 Recommendation: Extend in the current amount for a period of one (1) year. 31. Troubadour, Section 15 – Performance Bond for Wastewater Collection System located off Cox Road. - $60,600 Recommendation: Extend in the current amount for a period of one (1) year. 32. Vineyard Valley, Section 2 – Maintenance Bond for Roads, Drainage and Erosion Control located off Eudailey-Covington Road. - $154,000 Recommendation: Extend in the current amount for a period of one (1) year, or when Engineering staff has determined the improvements have been completed and the bond is ready for review by the Planning Commission, whichever comes first. DEFERRAL ITEMS: ITEM 36 PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION, CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO- COLLEGE GROVE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). At this time, the applicant is requesting deferral to the August 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 5 of 9 OLD BUSINESS: ITEM 23 ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVIST A SUBDIVISION, SECTIONS 1 AND 2. Brent Thoeny, with TruLand Consultants, represented the applicant, The Jones Company. He reported that in Phase Two (2), most everything has been completed except for a headwall that needs to be touched up due to some erosion. The wastewater road was touched up and recompacted . Binders should be going down the next day and the top coat will be done the first part of next week. The pond has been completed and a flume has been put in. However, with the rain we’ve had, it’s been hard to tell if it is draining perfectly or not, but they will reassess it when they can. Other than these items, all other physical items in Phase 2 have been completed. In Phase One (1), all of the pond work has been regraded. The only outstanding items are the swale on Long Lane, which is approximately seventy percent (70%) complete, and should be completed in the next few days. T-Square is working on the Site Plan for the mailbox kiosk, but all other physical work for Phase 1 has been completed. Chairman McCoy asked what he meant by the mailbox kiosk. Mr. Theony advised that they could not find a copy of where the mailbox kiosk Site Plan had been originally approved, so they were having it located again. Chairman McCoy asked if there were any other questions. Hearing none, he opened the floor to Mr. Scott for his presentation. Mr. Scott reviewed the current open issues for Sections 1 and in a PowerPoint presentation. Some of the open issues were confirmation of the street inlet, storm water pipes, etc., and he expected confirmation from the Engineer once completed. The Site Plan for the mail kiosk was requested in February, which was what Mr. Theony previously referred to. Mr. Scott showed photos of multiple items in Section 1 , including pond 2A, which has had some work done and is looking better . However, it is still on the list, because there is a gabion basket that is shown on the plans and there is some ponding, so he wants to make sure grass takes and it is stable. The water quality swale is still being worked on, as well as pond 1, which has been re- graded. There is still some ponding, and it is unknown if it will require a French drain, but the grass should be grown in and it will need to be maintained. Pond 2B is similar, and also calls for a level spreader or gabion. There is an inlet that has some strong grades around it, which is why it is still on the list. There are still thirteen ( 13) open issues, but most have been completed or are in the process. In Section 2, the wastewater access road should be completed within the next week. Detention pond 5 had some ponding, but it does have a flume, so it may be that some of the straw has gotten into the flume and caused some clogging. As the grass grows and the straw is no longer there, it will be better. There are also some flumes that hav e been put in that look good. There is still a sinkhole issue that he is waiting for Geotech to address. He reviewed the slopes that were on the approved grading plans . Section 1 looks good, but Section 2 shows some steeper slopes, so he has asked for re -grading to areas that are steeper than two to one (2:1). This would be a significant undertaking and could cause more issues than it could solve, but there have been landslides there in the past, so he wants to make sure everything is taken care of. Mr. Scott spoke to Tim Turner with T-Square about this and Mr. Turner felt like it would be better if a Geotech reviewed the issue to determine if the slopes need to be re-graded or if they are stable. Commissioner Lucyshyn asked if the documentation showing where Mr. Scott asked about a Geotech report in February 2025 is still the report that he is waiting on currently. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 6 of 9 Mr. Scott advised that there were two (2) depressions or sinkholes that looked like they had throats and he believes a Geotech had gone out there and did mat over those areas, but when Mr. Scott went back out during a recent visit, the throat had opened back up. Therefore, he feels this is an ongoing issue and he feels there is not a sol ution yet for these. Mr. Theony stated that the first Geotech report referenced those holes and were defined as dropout, not actually a sinkhole. They have since gone back and fixed those again and Mr. Scott may want to take a look at them again. Commissioner Lucyshyn advised that, per Mr. Scott’s report, there is a note dated May 13, which advises that the sinkhole may still be active. Mr. Scott confirmed that was correct. Commissioner Lucyshyn asked if there was an answer for that note. Mr. Theony stated that it is the same area and incident that happened , and he believes the Geotech advised that there was no guarantee that it wouldn’t happen again. He will talk to the Geotech about going back out there. Commissioner Crohan asked for more information about what Mr. Wigger had mentioned earlier regarding the irrigation system. Mr. Theony advised that he didn’t know much, but he was copied on an email that day where the HOA attorney had stated that the HOA determined the irrigation pump in the subdivision had to be replaced and they demanded that Jones Company pay for this. Per his knowledge, Jones Company has already replaced it once before approximately two (2) years ago. Commissioner Crohan asked if it had been replaced recently. Mr. Theony stated it was approximately two (2) years ago. Commissioner Crohan asked if he was aware of anything currently wrong with it. Mr. Theony responded that from the email he received it appeared to have already been replaced and were asking Jones Company to pay for it. County Attorney, Kristi Ransom, advised that the County does not bond irrigation systems and it is not part of the Roads, Drainage and Erosion Control bond. Commissioner Crohan asked when this project was going to be completed and that he doesn’t want to see it going into winter. Mr. Theony stated that he intended for it to be completed within the next five (5) to ten (10) days. Commissioner Bailey advised that it is hard for the Planning Commission to see based on narrative updates what is actually taking place as far as the work that is being done. He feels that it is great that everything should be completed by the next Planning Commission meeting, but if it were not, he would like to see a chart that plainly shows what items are left and when they are scheduled to be executed. Mr. Theony agreed to that. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 7 of 9 PRELIMINARY PLATS: ITEM 34 PRELIMINARY PLAT REVIEW FOR WILD OAK LLE SUBDIVISION, CONTAINING 5 LOTS ON 35.60 ACRE S LOCATED OFF COLEMA N ROAD IN THE 9 TH VOTING DISTRICT (1-2026-308). Mr. Sweet reviewed the background (see Staff Report) recommending approval of this Preliminary Plat with the following conditions: 1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a Land Disturbance Permit; 2. Fire hydrants shall be installed within 500 feet of all building envelopes. A report from H.B. & T.S. Utility District shall be submitted prior to Final Plat approval certifying the flow rates of all hydrants meet the required minimum rate of 500 gpm; 3. Establishment of a Performance Bond for water improvements in favor of H.B. & T.S. Utility District; 4. A Land Disturbance Permit must be obtained for the overall development; and 5. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be complete, consistent with Zoning Ordinance requirements. The applicant shall notify Engineering Department Staff in order to conduct the required inspection. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner Clifford made a motion to approve per Staff recommendation. Commissioner Bailey seconded the motion. The motion was unanimously approved. ITEM 35 FINAL PLAT REVIEW FO R FOSTER SUBDIVISION FAMILY SUBDIVISION, CONTAINING 1 LOT ON 1.40 ACRES LOCATED O FF TALIAFERRO ROAD I N THE 5TH VOTING DISTRICT (1-2026-409). This Item has been Withdrawn. This Item is on the Consent Agenda for Deferral. ITEM 36 PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION, CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GROVE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). Williamson County Planning Commission Meeting of Jul 9, 2026 Page 8 of 9 FINAL PLATS: ITEM 37 FINAL PLAT REVIEW FO R MARLOWE SPRINGS AT CARL ROAD SUBDIVISI ON, CONTAINING 5 LOTS ON 91.81 ACRES LOCATED OFF CARL ROAD IN TH E 9TH VOTING DISTRICT (1-2026-413). Mr. Sweet reviewed the background (see Staff Report) recommending approval of this Preliminary Plat with the following conditions: 1. The applicant shall adopt and record a covenant that declares that the access easement is not a public road, and imposes the requirem ent of maintenance by all properties served by the access easement. The covenant shall be recorded concurrently with the recording of the plat; and 2. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire apparatus access requirements for all lots, prior to building permit issuance. Chairman McCoy asked if there were any questions. Commissioner Crohan asked if the stub road was going to be for future development. Mr. Sweet clarified that this was just a continuation of the subdivision road on the plans and not a road stubbed to an adjacent property. Commissioner Crohan made a motion to approve per Staff recommendation. Commissioner Clifford seconded the motion. The motion was unanimously approved. ITEM 38 FINAL PLAT (REVISED) REVIEW, FLINT MEADO WS SUBDIVISION, CONTAINING 3 LOTS ON 18.25 ACRES LOCATED OFF STEEPLECHASE LA NE IN THE 8TH VOTING DISTRICT (1-2026-400). Mr. Waldrop reviewed the background (see Staff Report) recommending approval of this Final Plat with the following conditions: 1. Fire hydrants shall be installed within 500 feet of all building envelopes. A report from Harpeth Valley Utility District shall be submitte d prior to Final Plat approval certifying the flow rates of all hydrants meet the required minimum rate of 500 gpm; and 2. The applicant shall submit a signed and notarized ‘Family Subdivision Affidavit and Restrictive Covenant,’ which shall be recorded concurrently with the recording of the plat. After the ‘Family Subdivision Affidavit and Restrictive Covenant’ has been recorded and prior to application for building permits, t he applicant shall provide a copy to the Planning Department. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner Crohan made a motion to approve per Staff recommendation. Commissioner Bailey seconded the motion. The motion was unanimously approved. Williamson County Planning Commission Meeting of Jul 9, 2026 Page 9 of 9 NON-AGENDA ITEM PINE CREEK, SECTION 2 - MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM Mr. Holmes advised that the Bond has satisfied the requisite two (2) year maintenance period, and Staff recommended to release the Bond. Chairman McCoy asked if there were any other questions. Hearing none, he asked for a motion. Commissioner Crohan made a motion to approve per Staff recommendation. Commissioner Lane seconded the motion. The motion was unanimously approved. Chairman McCoy asked for a motion to adjourn. Commissioner Clifford made a motion to adjourn. There being no further business, the meeting was adjourned at approximately 5:57 p.m. APPROVED BY A MAJORITY VOTE BY THE WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION ON AUGUST 13, 2026 ____________________________________ Chairman CONSENT AGENDA WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION WILLIAMSON COUNTY ADMINISTRATIVE COMPLEX AUGUST 13, 2026 BONDS: 3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro Road. - $67,950 Recommendation: Extend in the current amount for a period of six (6) months. 4. King’s Chapel, Section 12 - Maintenance Bond for Wastewater Collection System located off Murfreesboro Road. - $21,000 Recommendation: Release the bond. 5. Lookaway Farms, Section 3 – Maintenance Bond for Wastewater Collection System located off Clovercroft Road. - $15,000 Recommendation: Release the bond. 6. Starnes Creek , Section 2 –Maintenance Bond for Wastewater Collection System located off Meeks Road. - $12,900 Recommendation: Release the bond. 7. Starnes Creek Wastewater Area – Maintenance Bond for Wastewater Treatment and Disposal System located off Meeks Road. - $120,700 Recommendation: Release the bond. 8. Terravista, Section 2 - Maintenance Bond for Wastewater Collection System located off Long Lane. - $48,300 Recommendation: Release the bond. 9. Reeds Vale, Section 1 – Maintenance Bond for Wastewater Collection System located off Lampkins Bridge Road. - $96,600 Recommendation: Release the bond. 10. The Grove, Section 14 – Maintenance Bond or Roads, Drainage and Erosion Control located off Arno Road. - $425,000 Recommendation: Release the bond. DEFERRAL ITEMS: ITEM 12 PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION, CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO-COLLEGE GROVE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 16 SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 17 SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG WRITER’S CABINS, ON 2.5 ACRES LOCATED OFF CLUB VIEW DRIVE IN THE 5TH VOTING DISTRICT (5-2026-006). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 18 CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON 108.16 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (1 - 2026-203). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 19 CONCEPT PLAN REVIEW FOR 1600 RIVER LANDING D RIVE SUBDIVISION, CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING DRIVE IN THE 9TH VOTING DISTRICT (1-2026-204). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. FINAL PLATS: ITEM 22 FINAL PLAT REVIEW FOR THE GROVE SUBDIVISION, SECTION 18, CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND VOTING DISTRICT (1-2026-414). Final Plat is in order, and Staff recommends approval with the following conditions: 1. Establishment of a maintenance bond for water improvements in favor of Milcrofton Utility District in the amount of $44,332.30; 2. Per the recommendation of the County’s Wastewater Consultant, establishment of a performance bond for the wastewater collection system in the amount of $137,924.71; 3. Execution of performance agreements for the above reference d sureties; 4. The approved HOA documents must be recorded concurrently with the recording of the Final Plat; 5. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and 6. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. MOTION TO ACCEPT STAFF RECOMMENDATION 1 st _____ 2nd ______ VOTE: ___________ NOTE: All matters listed under the consent agenda are considered to be routine. There will be no separate discussion of these items unless a Planning Commission member so requests, in which case it will be removed from the Consent Agenda so that discussion may be held on that item. Reviewer: OCW Date: 08/13/2026 ITEM 3 NAME: 1200 OLD HILLSBORO ROAD BOND TYPE: MAINTENANCE BOND FOR LANDSCAPING LOCATION: OLD HILLSBORO RD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT April 2022 Performance Landscaping Implemented $90,600 February 2024 Performance Landscaping Extend $90,600 February 2025 Performance Landscaping Extend $90,600 February 2026 Performance Landscaping Reduce to Maintenance & Extend $67,950 LAST ACTION: At the February 2026 meeting, this body granted approval reduced to Maintenance in the amount of $67,950 for a period of six (6) months. RECOMMENDATION: Staff visited the site and noted the landscaping ha d been installed. Staff recommends extending the bond for six (6) mont hs to allow completion of the Maintenance Period. CURRENT RECOMMENDED $67,950 $67,950 Maintenance Maintenance Reviewer: AVH Date: 08/13/2026 ITEM 4 NAME: KING’S CHAPEL, SECTION 12 BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM LOCATION: OFF MURFREESBORO RD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT July 2022 Performance WW Collection System Implemented $70,000 August 2023 Performance WW Collection System Extend $70,000 August 2024 Performance WW Collection System Reduce to Maintenance and Extend $21,000 LAST ACTION: At the August 2024 meeting, this body granted approval for this bond to be reduced to maintenance in the amount $21,000 for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the bond . CURRENT RECOMMENDED $21,000 Maintenance Release Reviewer: AVH Date: 08/13/2026 ITEM 5 NAME: LOOKAWAY FARMS, SECTION 3 BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM LOCATION: OFF CLOVERCROFT RD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT August 2022 Performance WW Collection System Implemented $50,000 August 2023 Performance WW Collection System Extend $50,000 August 2024 Performance WW Collection System Reduce to Maintenance and Extend $15,000 LAST ACTION: At the August 2024 meeting, this body granted approval that this bond be reduced to maintenance in the amount of $15,0 00 for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the b ond. CURRENT RECOMMENDED $15,000 Maintenance Release Reviewer: AVH Date: 08/13/2026 ITEM 6 NAME: REEDS VALE, SECTION 1 BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM LOCATION: OFF LAMPKINS BRIDGE ROAD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT May 2023 Performance WW Collection System Implemented $322,000 May 2024 Performance WW Collection System Extend $322,000 August 2024 Performance WW Collection System Reduce to Maintenance and Extend $96,600 LAST ACTION: At the May 2024 meeting, this body granted approval that this bond be reduced to maintenance in the amount of $96,6 00 for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the bond. CURRENT RECOMMENDED $96,600 Maintenance Release REVIEWER: AVH DATE: 08/13/2026 ITEM 7 NAME: STARNES CREEK, SECTION 2 BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM LOCATION: OFF MEEKS RD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT July 2023 Performance WW Collection System Implemented $43,000 July 2024 Performance WW Collection System Reduce to Maintenance and Extend $12,900 LAST ACTION: At the July 2024 meeting, this body granted approval that this bond be reduced to maintenance in the amount of $12,900 for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the bond. CURRENT RECOMMENDED $12,900 Maintenance Release REVIEWER: AVH DATE: 08/13/2026 ITEM 8 NAME: STARNES CREEK WASTEWATER AREA BOND TYPE: MAINTENANCE BOND FOR WASTEWATER TREATMENT AND DISPOSAL SYSTEM LOCATION: OFF MEEKS RD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT January 2019 Performance WW Treatment and Disposal Implemented $120,700 August 2023 Performance WW Treatment and Disposal Extend $120,700 August 2024 Performance WW Treatment and Disposal Reduce to Maintenance and Extend $120,700 LAST ACTION: At the August 2024 meeting, this body granted approval that this bond be converted to maintenance in the current amount for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the bond. CURRENT RECOMMENDED $120,700 Maintenance Release REVIEWER: AVH DATE: 8/13/2026 ITEM 9 NAME: TERRAVISTA, SECTION 2 BOND TYPE: MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM LOCATION: OFF LONG LANE BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT September 2022 Performance WW Collection System Implemented $161,000 August 2023 Performance WW Collection System Extend $161,000 August 2024 Maintenance WW Collection System Reduce to Maintenance and Extend $48,300 LAST ACTION: At the August 2024 meeting, this body granted approval that this bond be reduced to maintenance in the amount of $48,300 for a period of two (2) years. RECOMMENDATION: This bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommends releasing the bond. CURRENT RECOMMENDED $48,300 Maintenance Release Reviewer: MS Date: 08/13/2026 ITEM 10 NAME: THE GROVE, SECTION 14 BOND TYPE: MAINTENANCE BOND FOR ROADS, DRAINAGE AND EROSION CONTROL LOCATION: OFF ARNO ROAD BACKGROUND: The following table shows the previous history of the bond. MEETING DATE BOND TYPE ACTION TAKEN BOND AMOUNT November 2020 Performance RDE Implemented $850,000 December 2021 Performance RDE Reduce to Maint & Extend $623,000 December 2022 Maintenance RDE Extend $623,000 December 2023 Maintenance RDE Extend $623,000 December 2024 Maintenance RDE Extend $623,000 December 2025 Maintenance RDE Reduce & Extend $425,000 LAST ACTION: At the December 2025 meeting, this body granted approval to reduce the Maintenance Bond to $425,000 and extend for a period of one (1) year. RECOMMENDATION: Staff visited the site an d noted that all improvements are complete. The roadways are private and will be maintained by the HOA. Staff recommends that the Maintenance Bond be released. CURRENT RECOMMENDED $425,000 Maintenance Release Item 11—Page 1 of 1 Reviewer: MS Date: 8/13/2026 ITEM 11 TERRAVISTA ROADS, DRAINAGE, AND EROSION CONTROL BOND UPDATE Item 12—Page 1 of 1 Reviewer: LS Date: 8/13/2026 ITEM 12 PRELIMINARY PLAT REVIEW FOR LOFTY MEADOW ESTATES SUBDIVISION, CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GROVE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). Area 32.3 acres Lots 5 Zoning Rural Development-5 (RD-5) Water Milcrofton Utility District Sewer Individual On-Site Septic Systems Development Options Large Lot Easement Chapter 1101 Status Rural Map and Parcel 142---02901 File Number (1-2025-310) At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Item 13—Page 1 of 2 Reviewer: LS Date: 8/13/2026 ITEM 13 PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY LLE SUBDIVISION , CONTAINING 1 LOT ON 20.33 ACRES LOCATED OFF TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-301). Attachment 13-1 Preliminary Plat 13-2 Aerial Photograph 13-3 Request for Variance 13-4 Applicant’s Petition for Variance Area 20.33 acres Zoning Rural Development-5 (RD-5) Lots 1 Water Individual Well Sewer Individual On-Site Septic System Development Option Large Lot Easement Chapter 1101 Status Rural Map and Parcel 159---01104 File Number (1-2026-301) The subject parcel is approximately twenty (20) acres in size and is located off Taliaferro Road, approximately 1/3 of a mile nort h of John Windrow Road . The applicant is requesting approval of a Large Lot Easement Subdivision in order to create the second (2 nd) lot off an existing fifty-foot (50’) ingress/egress/utilities easement known as Bo Lane. All Zoning Ordi nance requirements, including those regarding the protection of natural resources, have been met. The applicant is proposing individual septic systems for the lot, and the Williamson County Department of Sewage Disposal Management has approved the request. Water will be provided by an individual private well . As no fire hydrants are proposed, fire sprinkler systems shall be installed in all habitable structures on Lot 1, as outlined in Section 3.05(B)(2)(b)(i) of the Subdivision Regulations . This has been made a condition of approval. The property in question will take access from Bo Lane, an existing fifty-foot (50’) easement that has been in existence since 2001 and extends from Taliaferro Road and serves the applicant’s lot and one (1) other lot , which is located at the end of Bo Lane and within Rutherford County . The existing driveway varies betwe en twelve (12) and sixteen (16) feet in width for the entire length of Bo Lane. As the existing, varying-width driveway does not meet the required 16 -foot driveway width per Section 3.02(D)(2) of Item 13—Page 2 of 2 Reviewer: LS Date: 8/13/2026 the Subdivision Regulations, the applicant is requesting a Variance from Section 3.02(D)(2) of the Subdivision Regulations so as not to be required to widen the easement to sixteen (16) feet where it currently is not sixteen (16) feet in width (See Attachments 13-3 and 13-4). Because the easement has been in exis tence since 2001 , and because the applicant is willing to sprinkle all habitable structures, Staff is not opposed to the Variance. The Preliminary Plat is in order , and so long as the Planning Commission grants the Variance, Staff recommends approval, subject to the following conditions, which must be addressed in conjunction with Final Plat submittal: 1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a Land Disturbance Permit, if there is 1-acre or more of disturbance; 2. Prior to submittal of the Final Plat, provide a letter from the water provider either stating the water lines are installed and functioning or listing a Performance Bond amount for water improvements; 3. A Land Disturbance Permit must be obtained for the overal l development; 4. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be complete, consistent with County regulations; 5. Satisfaction of Section 3.05 of the Subdivision Regulations, as it pertains to fire sprinkler system requirements; and 6. Affixing a note to the Plat noting that all structures, including accessory structures, shall be separated by a minimum of 200 feet . ROAD TALIAFE FERRO ROAL PIN2 IRON 93241 876 EXISTING DIDIR N 000240 W 993.:21 M.B.S THOMAS R. BENNING AFERRO ROAD 5R.O.W.C RON IRON LOT 821 PAGE 514 ROWC 20.03 ACRES 872,715 SQ.FT. FORPRINCIPAL WILLIAMDY oUNTY LOCATI CATION PER DEED; APPROX.) RUTHERFORD COUNTY (APPROX. LOCATION FOUND PIN AREA MАР SCALE 1":100' LANE STUMP HOLE MAY BE PLAT BOOK J PACE IEB R (APP 28.92 A OT A PART OF THIS SUBDIVISION) MARIA A FENA RECTURD BOIK S PAGIE LEGEND ND ELECTH ASPHALT SURP SCALE: STATS PLANE STATE PLANE NORTH CHAPDELAINE & ASSOCIATES LAND SURVEYING FAIR AFERRO BO LANE SITE N.T.S. SITE MAP 2 TEMEN ISNOT A GENERAL RULE 0820-03-07 ATE BOARD OF PRELIMINARY PLAT ED LAND O NNESSEE NO 4 Ana 2026 RELIMINARY RT PAUL RUSSELL COLE DANIELLE RUSSELL E- EAGLEVILLE, TN DEED BOOK 9821 PAGE 514 R.O.w.c. BOOK P44 PAGE 104 R.O.W.C. TY MAP 159 PARCEL 11. LOTI 2.122.5a5 TOTAL S V-0.0 LAH RGE LOT OFF AN EASEMENT SUBDIVISIO ION LOT 1 OF THE T LARRY U. TURNER PROPERTY SUBDI ОIVISION ATE ATTACHMENT 13-1 Property: Tax Map 159, Parcel 01104 (approximately 49 acres, accessed via Bo Lane) Dear Members of the Planning Commission: FACTS 41468101vl DOUGLAS BERRY Direct Dial 615-744-8620 Direct Fax 615-744-8635 doug.berry@millermartin com Williamson County Regional Planning Commission c/o Williamson County Planning Department 1320 West Main Street, Suite 400 Franklin, Tennessee 37064 This letter addresses a single issue, relief from the 16-foot shared driveway width requirement of the Sub Regs. The Applicants’ legal positions taken in the case pending before the Board of Zoning Appeals, and all other legal rights and remedies, are expressly reserved. The grant of the variance requested here would resolve this matter, however, and obviate the need for further proceedings. Bo Lane was created on April 26, 2001, with the recording of the survey of the Larry U. Turner property, as a non-exclusive, fifty-foot-wide ingress-egress and utility easement (Plat Book 31, Page 103) (Exhibit 1, attached) (Hereinafter “the Turner Survey”). Bo Lane extends westerly to Taliaferro Road, a public road. Shortly after the recording of the Turner Survey, in separate transactions, the Turners sold Tracts 5 and 9 to one buyer and Tract 8 to another buyer. These tracts have enjoyed continuous right of access to Taliaferro Road via Bo Lane. Tracts 8 and 9 lie in large part within Rutherford County and are to the east of the Property, that is, further away from Taliaferro Road. The deeds to these tracts are attached as Exhibits 2 and 3. Both deeds contain reciprocal obligations for maintenance of the access easement. 401 Commerce Street Suite 720 Nashville, TN 37219-2449 615-244-9270 Fax 615-256-8197 MILLERMARTIN Re: Petition for Variance from 16-Foot Shared Driveway Width Requirement, Section 3.02(D)(2)(a) of the Williamson County Subdivision Regulations This firm represents Robert and Nicole Russell (“Applicants”), the owners of an approximately 49- acre parcel accessed by Bo Lane (“the Property”), which is a recorded 50-foot ingress/egress and utility easement. Pursuant to Section 1.09(A) of the Williamson County Subdivision Regulations (the “Sub Regs”), the Applicants respectfully request a variance from the requirement in Section 3.02(D)(2)(a) that lots in a Large Lot Easement (“LLE”) Subdivision must take access from a shared driveway with a minimum width of 16 feet. ATTACHMENT 13-4 APPLICABLE STANDARD Section 1.09(A) of the Sub Regs provides: DISCUSSION 41468101vl In other words, the Sub Regs already recognize that sprinklers combined with 200-foot building envelope separation are a substitute for the apparatus access standards, including the 16-foot width component. 1. The Sub Regs Provide and the Applicants Have Committed to an Alternative Standard That Serves the Same Purpose as the 16-Foot Width Requirement. Williamson County Regional Planning Commission Page 2 The Property is composed of Tract 7 and a portion of Tract 4 as shown on the Turner Survey. Tract 4 has had access to Bo Lane continuously since the easement’s creation. Tract 7 does not appear to have ever had access to Bo Lane. The Property itself was created by deed in 2022 by three parties unrelated to the Applicants. The Applicants purchased the Property in 2025 to construct a single-family home. See Exhibit 4. No new roads or utilities are proposed. The Property satisfies the requirements applicable to an LLE Subdivision under the Sub Regs with a single exception: the 16-foot minimum shared driveway width specified in Section 3.02(D)(2)(a). With respect to fire protection, the applicants have agreed to install automatic sprinkler systems in all habitable structures on the Property and to space building envelopes no closer than 200 feet apart - a combination that, as explained below, the Sub Regs expressly treat as a substitute for the fire apparatus access standards, including the 16-foot shared driveway width contained within those standards. “Whenever a parcel of land to be subdivided contains extraordinary, exceptional or unique situations, or is surrounded by such development of unusual conditions that the strict application of the requirements contained in these Regulations would result in substantial hardship or inequity, the Planning Commission may vary or modify, except as otherwise indicated, such requirements of design, but not of procedure or improvements, so that the subdivider may develop the property in a reasonable manner, keeping in mind that the public welfare and interests of the County are protected and the general intent and spirit of these Regulations are preserved. Such modifications may be granted by the Planning Commission upon written request by the subdivider, stating the reason(s) for each modification.” The purpose of the 16-foot shared driveway width is to ensure adequate fire apparatus access. The fire protection standards of Section 3.05(B)(2) confirm as much: under Section 3.05(B)(2)(b), where fire hydrants are not provided, building envelopes must be spaced no closer than 200 feet apart, and the applicant must then provide either (i) sprinkler systems in all habitable structures, or (ii) the full fire apparatus access package - which includes maximum driveway grades, turnaround requirements, an apparatus staging area, and the same 16-foot minimum shared driveway width. 41468101vl Widening Bo Lane to 16 feet would require reconstructing approximately 3,200 linear feet of travel way, and is not practically feasible without materially disturbing existing infrastructure, neighboring operations, and natural features, including: The Applicants sought the Fire Service’s review of Bo Lane early and accept its conclusion that the road, in its present condition, does not meet the apparatus-access standard. That conclusion is why the Applicants have committed to the alternative the Sub Regs themselves provide: sprinkler systems in every habitable structure, which act on a fire before apparatus arrives at all. Section 3.05(B)(2)(b) does not require both. 3. Widening Bo Lane Is Physically Impossible Without Substantial Impact to Third Parties and Approvals from Agencies Outside the County’s Control. The Applicants have committed to sprinkler systems in all habitable structures and a minimum 200- foot separation between building envelopes. The safety objective underlying the 16-foot width requirement is therefore fully served here through the alternative path the drafters of the Sub Regs themselves provided. 2. The Applicants Cannot Widen Bo Lane Without Displacing Rights Held by Others and Requiring Them to Bear That Burden Alone Would Be Inequitable. Page 3 Thus, granting the requested variance does not ask the Commission to waive a safety protection; it asks the Commission to recognize that the Sub Regs’ own alternative protection is being provided. The Williamson Fire/Rescue Coordinator, in his April 15, 2026, letter (Exhibit 6) made this very observation, suggesting that it would be equitable for neighbors or county government to share in the cost of any required improvements rather than placing the entire financial burden on a single property owner. That is precisely the “substantial hardship or inequity” that Section 1.09(A) empowers this Commission to relieve. Bo Lane is a non-exclusive easement. The Applicants share it with other owners holding co-equal rights of use. The easement also carries recorded utility interests serving neighboring households. The Applicants do not have the right to widen Bo Lane without disturbing improvements that are not theirs to disturb. They have no legal authority to relocate recorded interests held by others. Private water lines serving three neighboring households run within the corridor along its southern edge - themselves an authorized use of an easement granted for utilities as well as access, and expressly excepted in the recorded conveyances. One neighboring landowner’s fencing for an active livestock operation borders the northern edge. Any widening reaches one or both. The Applicants have no right to displace their neighbors’ water service and no means of compelling the cooperation that widening would require. On the other hand, requiring the Applicants alone to bear the burden and expense of physically expanding a shared easement that benefits multiple existing homes would impose the entire cost of a shared benefit on a single property owner. The scope of that work is substantial: reconstruction of approximately 3,200 linear feet of travel-way, excavation of new drainage ways, installation of new culvert pipes, relocation of the water lines serving three neighboring households, and relocation of a neighboring landowner’s fencing - estimated at $150,000, per the enclosed estimate. (Exhibit 5). • Ditches, drainage features, and mature trees immediately adjacent to the existing travelway. Photographs documenting each of these are attached as Collective Exhibit 7. 4. Strict Application of the Requirement Is Causing Substantial, Ongoing Hardship. 5. This Situation Was Not Caused by Any Act or Omission of the Applicants. 41468101vl • A stream crossing and culvert along the route of Bo Lane, identified as waters of the United States, the modification of which would likely require consent from the U.S. Army Corps of Engineers and the Tennessee Department of Environment and Conservation; • Private water lines serving three neighboring households, running along the entire southern edge of Bo Lane, together with telephone and power lines and the utility easements of record at Book 1972, Pages 949 and 951; Page 4 • A neighboring landowner’s active livestock operation - including fencing and a barn - bordering the entire northern edge of Bo Lane; and • Utility distribution poles set within the corridor, which can be relocated only by the utilities that own them; • A transmission line crossing Bo Lane, of record at Book 387, Page 561 and Book 392, Page 730, such that widening would likely require approval from the Tennessee Valley Authority; Absent relief, the Applicants cannot obtain building permits for a single-family residence through the ordinary permitting process and cannot develop their 49-acre parcel in the reasonable manner that Section 1.09(A) exists to permit. The hardship is not abstract or prospective - it is ongoing and concrete. Equipment maintained on the Property (tractor, implements, trailer) remains exposed to the elements; water must be manually hauled to the site; and the absence of permitted infrastructure limits the Applicants’ ability to care for, and provide predator protection for, their own livestock currently on the Property. Each day the 16-foot requirement is strictly applied to a corridor the Applicants have no practical ability to widen, this hardship compounds. These conditions are exactly the “extraordinary, exceptional or unique situations” and “unusual conditions” surrounding a parcel that Section 1.09(A) contemplates. The Applicants did not create Bo Lane, were not a party to the 2001 survey that established the easement and were not a party to the 2022 deed subdivision, which was effected by three completely unrelated parties. The constraints described above are recorded interests and long-standing physical conditions that predate the Applicants’ acquisition of the Property by more than two decades. Before purchasing, the Applicants performed due diligence on the access requirements they understood to apply, including the 50-foot easement width and the limitation on the number of lots served by the easement, both of which are satisfied. Since acquiring the Property, they have worked cooperatively with County staff and have satisfied every requirement identified, arriving at the 16-foot shared driveway width as the sole outstanding item. While Section 1.09(A) does not expressly require it, the absence of any self-created hardship further supports the equity of granting relief. CONCLUSION Sincerely, MILLER & MARTIN, PLLC By: 41468101vl Williamson County Regional Planning Commission Page 5 Accordingly, the Applicants respectfully request that the Planning Commission grant a variance from the 16-foot shared driveway width requirement of Section 3.02(D)(2)(a) of the Sub Regs as applied to the Property. We appreciate the Commission’s consideration and are available to answer any questions or provide any additional information that would be helpful. The Property presents extraordinary, exceptional and unique circumstances: a quarter-century-old shared easement the Applicants have no practical ability to widen without displacing recorded rights held by others, hemmed in by a transmission line, a stream crossing, neighbors’ private water and utility lines, a neighboring livestock operation, utility poles, and mature trees. Strict application of the 16-foot width requirement in these circumstances works substantial hardship and inequity - preventing the reasonable development of a 49-acre parcel and imposing on a single owner the burden of improving a corridor shared by many. At the same time, the public welfare remains fully protected: the Applicants have committed to the sprinkler and building-envelope-separation alternative that the Sub Regs themselves treat as an adequate substitute for the fire apparatus access standards, and Bo Lane will continue to function exactly as it has for the surrounding community for 25 years. A Douglas Berry \ ) Direct Dial Number: (615) 744-86: cc: Robert and Nicole Russell Williamson County Zoning Attorney Kristi Ransom EXHIBIT 1 ***% 8 w in V s *P LARRY U. TLF1NER «-os amE =z==BRRT=7H=E a===mtmeem"u pet yRbtsplly c.-^b EXHIBIT 2 ( This Instrument Prepared By: 4 NEW OWNER: SAME The actual consideration or value, whichever is greater, for this transfer is $60,000.00. WARRANTY DEED ) STATE OF TENNESSEE COUNTY OF WILLIAMSON Part of: Map 159 Parcel 11, 11.01 & 14.01 Being part of the same property conveyed to Larry U. Turner and wife, Catherine D. Turner by warranty deeds of record in Book 320, page 413, Book 362, page 624, Book 836, page 856 and Book 1045, page 191; and Book 496, page 415, Register’s Office for Rutherford County, Tennessee. Being Tract No. 8, of the Survey for Larry U. Turner Property, of record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee, together with that certain non-exclusive fifty (50’) feet wide ingress-egress and utility easement set forth on said survey and the rights of use and obligations of shared maintenance with Tract No. 9 shown on said survey. Douglas S. Hale, Attorney / HALE AND HALE, PLC 312 First Tennessee Bank Building Franklin, Tennessee 37064 04/ Ur VAFFIANT For and in consideration of the sum of Ten Dollars, cash in hand paid by the hereinafter named GRANTEES, and other good and valuable considerations, the receipt and sufficiency of which is hereby acknowledged, LARRY U. TURNER and wife, CATHERINE D. TURNER, hereinafter called the "GRANTORS", have bargained and sold and by these present do transfer and convey unto TIMOTHY R. DOWELL and wife, WENDY R. DOWELL and CHARLES E. S. RUSSELL and wife, ALISHA RUSSELL, hereinafter called the "GRANTEES", their heirs and assigns, a certain tract or parcel of land in Williamson and Rutherford County, Tennessee, described as follows, to-wit: Sworn to and subscribed before me this & t—day of May, 2001. — . * BK 2174 PG 312 Timothy R. Dowell, et al. 5/7 Newcastle n. Hermi faqe ,7~ 37076 SEND TAX BILL TO: MAP & PARCEL ' "V _AQ —NOTARY PUBLIC - 45, •5 ■ My Commission Expires: ( 2362 5. Utility Easement of record in Book 1972, page 949 and Book 1972, page 951, Register’s Office for Williamson County, Tennessee (as to easement). 6. Right of way for Taliferro Road (as to easement). No commercial enterprises allowed.a. b. Any residences of any type built on the property must have a minimum of Double wide mobile homes and modular homes must have a minimum ofc. d. Any extra buildings must set behind the main residence. No single wide mobile homes allowed.e. f. All buildings must be placed at least 25 feet off any side lines. No swine or fowl will be permitted on any tract.g- No abandoned and/or inoperable vehicles, junk or litter of any kind shallh. be allowed outside any building. Property must be kept in a neat and orderly way. 1800 square feet of actual living heated area on the main floor and must set back a minimum of 500 feet from road right of ways. GRANTEES ARE RESPONSIBLE FOR THE PAYMENT OF ANY ROLL­ BACK TAXES ASSESSED UPON THE REAL PROPERTY DESCRIBED IN THIS WARRANTY DEED. 1800 square feet of actual living heated area on the main floor and must set back a minimum of 150 feet from road right of ways. AND GRANTORS do covenant with the said GRANTEES that they are lawfully seized and possessed of said land in fee simple, have a good right to convey it and the same is unencumbered, except as follows: TO HAVE AND TO HOLD the said tracts or parcels of land, with the appurtenances, estate, title and interest thereto belonging to said GRANTEES, their heirs and assigns, forever; EK 2174 PG 313 3. Ingress-Egress and Utility Easement of record on the plan of Larry U. Turner Property of record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee, and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee. 1. Williamson County taxes for the year 2001 are a lien against said property, but are not yet due and payable. Part of Map 159, Parcels 11, 11.01 and 14.01. 2. All matters appearing on the plan of Larry U. Turner Property of record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee. 4. Existing six (6") inch water line (as to easement). 7. The real property described in and conveyed by this Warranty Deed is subject to those covenants and restrictions set forth herein below, which shall be covenants running with the land and enforceable by the owners thereof through and including April 21, 2021 on which date the same shall terminate and expire: Witness my hand this day of May, 2001, in Franklin, Tennessee. V -Notary/Public s My Commission Expires: STATE OF TENNESSEE COUNTY OF WILLIAMSON Personally appeared before me, the undersigned, a Notary Public, in and for State and County, Larry U. Turner and wife, Catherine D. Turner, the within named bargainors with whom I am personally acquainted and who acknowledged that they executed the foregoing instrument for the purposes therein contained. " AND GRANTORS DO FURTHER covenant and bind themselves, their heirs and assigns, to warrant and forever defend the title to the said land to the said GRANTEES, their heirs and assigns, against the lawful claims of all persons whomsoever. Larry U. Turner ( Catki U vll. S cbul Catherine D. Turner ' * . % . ?• F 33 l WITNESS our hands this 8 day of May, 2001 in Franklin, Tennessee. State of Tennessee, County of WILLIAMSON Received for record the 08 day of MAY 2001 at 3:46 PM. (RECA 416346) Recorded in official records Bock 2174 eases 312- 314 Notebook 66 Pase 486 State Tax $ 222.00 Clerks Fee $ 1.00, Recordins $ 14.00, Total $ 237.00, Resister of Deeds SADIE MADE Deputy Resister PAMELA GREER BK 2174 PG 314 EXHIBIT 3 This Instrument Prepared By: NEW OWNER: SAME The actual consideration or value, whichever is greater, for this transfer is SI 40,000.00. My Commission Expires: R/ 29 6 WARRANTY DEED STATE OF TENNESSEE COUNTY OF WILLIAMSON Part of: Map 159 Parcel 11, 11.01 & 14.01 Being Tract Nos. 5 & 9, of the Survey for Larry U. Turner Property, of record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee, together with that certain non-exclusive fifty (50’) foot wide ingress-egress and utility easement set forth on said survey and the rights of use and obligation of shared maintenance with Tract No. 8 shown on said survey. Being part of the same property conveyed to Larry U. Turner and wife, Catherine D. Turner by warranty deeds of record in Book 320, page 413, Book 362, page 624, Book 836, page 856 and Book 1045, page 191; and Book 496, page 415, Register’s Office for Rutherford County, Tennessee. Douglas S. Hale, Attorney Lhale AND HALE, PLC 312 First Tennessee Bank Building Franklin, Tennessee 37064 TO HAVE AND TO HOLD the said tracts or parcels of land, with the appurtenances, estate, title and interest thereto belonging to said GRANTEE, his heirs and assigns, forever; - 2 For: and in consideration of the sum of Ten Dollars, cash in hand paid by the hereinafter named GRANTEE, and other good and valuable considerations, the receipt and sufficiency of which is hereby acknowledged, LARRY U. TURNER and wife, CATHERINE D. TURNER, hereinafter called the "GRANTORS", have bargained and sold and by these present do transfer and convey unto L. HOOPER INMAN, unmarried, hereinafter called the "GRANTEE", his heirs and assigns, certain tracts or parcels of land in Williamson and Rutherford County, Tennessee, described as follows, to-wit: L. Hooper Inman Ro. Eex $72 _____Fzawtely 70 370657 orkootttic Sworn to and subscribed before me this © day of May, 2001. RK 2174 PG 309 SEND TAX BILL TO: MAP & PARCEL All matters appearing on the Survey for Larry U. Turner Property of2. Ingress-Egress and Utility Easement of record on the plan of Larry U.3. Utility Easement of record in Book 1972, page 949 and Book 1972, page5. 951, Register’s Office for Williamson County, Tennessee. 7. Existing six (6") inch water line, telephone line and power line. 8. Right of way for Taliferro Road. 9. The real property described in and conveyed by this Warranty Deed is No commercial enterprises allowed.a. Double wide mobile homes and modular homes must have a minimum ofc. d. Any extra buildings must set behind the main residence. No single wide mobile homes allowed.e. f. All buildings must be placed at least 25 feet off any side lines. No swine or fowl will be permitted on any tract.g- h. No abandoned and/or inoperable vehicles, junk or litter of any kind shall be allowed outside any building. Property must be kept in a neat and orderly way. record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee. subject to those covenants and restrictions set forth herein below, which shall be covenants running with the land and enforceable by the owners thereof through and including April 21, 2021 on which date the same shall terminate and expire: Turner Property of record in Plat Book 31, page 103, Register’s Office for Williamson County, Tennessee, and Plat Book 24, page 74, Register’s Office for Rutherford County, Tennessee. GRANTEES ARE RESPONSIBLE FOR THE PAYMENT OF ANY ROLL­ BACK TAXES ASSESSED UPON THE REAL PROPERTY DESCRIBED IN THIS WARRANTY DEED. 1800 square feet of actual living heated area on the main floor and must set back a minimum of 500 feet from road right of ways. AND GRANTORS do covenant with the said GRANTEE that they are lawfully seized and possessed of said land in fee simple, have a good right to convey it and the same is unencumbered, except as follows: BK 2174 FG 310 1. Williamson County taxes for the year 2001 are a lien against said property, but are not yet due and payable. Part of Map 159, Parcels 11, 11.01 and 14.01. 4. Transmission Line Easement of record in Book 387, page 561 and Book 392, page 730, Register’s Office for Williamson County, Tennessee. 6. Subject to title to that portion of hte premises embraced within the bounds of a cemetary with all rights of ingress and egress thereto. b. Any residences of any type built on the property must have a minimum of 1800 square feet of actual living heated area on the main floor and must set back a minimum of 150 feet from road right of ways. / lotary Public 4My Commission Expires: STATE OF TENNESSEE COUNTY OF WILLIAMSON Personally appeared before me, the undersigned, a Notary Public, in and for State and County, Larry U. Turner and wife, Catherine D. Turner, the within named bargainors with whom I am personally acquainted and who acknowledged that they executed the foregoing instrument for the purposes therein contained. 00 Larry U. Turner latiuun . out Ut Catherine D. Turner State of Tennessee. County of WILLIAMSON Received for record the 08 day of HAT 2001 at 3:46 PM. (RECI 416345) Recorded in official records Bock 2174 eases 309- 311 Notebook 66 Pase 486 State Tax $ 518.00 Clerks Fee $ 1.00, Recordins $ 14.00, Total $ 533.00, Resister of Deeds SADIE WADE Deputy Resister PAMELA GREER Witness my hand this < day of May, 2001, in Franklin, Tennessee; AND GRANTORS DO FURTHER covenant and bind themselves, their heirs and assigns, to warrant and forever defend the title to the said land to the said GRANTEE, his heirs and assigns, against the lawful claims of all persons whomsoever. WITNESS our hands this 8 day of May, 2001 in Franklin, Tennessee. BK 21’7 4 PG 311 EXHIBIT 4 Book 9821 Page 514 WARRANTY DEED ( SEE File No.: 2025-1413 ADDRESS NEW OWNER(S) AS FOLLOWS: MAP/PARCEL NO(S).SEND TAX BILLS TO: (NAME) (NAME) STATE OF TENNESSEE COUNTY OF WILLIAMSON Spring (CITY) Spring (CITY) Land in Williamson County, Tennessee, being a portion of Lot No. 4A on the Plan of Minor Revision of Lot 4, Larry U. Turner Property of record in Plat Book P44, Page 104, Register's Office for Williamson County, Tennessee, and more particularly described as follows: THE ACTUAL CONSIDERATION OR VALUE, WHICHEVER IS GREATER, FOR THIS TRANSFER IS $590,000.00. SUBSCRIBED AND SWORN TO BEFORE ME, THIS THE 28TH DAY OF AUGUST, 2025. FOR AND IN CONSIDERATION OF THE SUM OF Five Hundred Ninety Thousand And No/100 Dollars ($590,000.00), CASH IN HAND PAID BY THE HEREINAFTER NAMED GRANTEE, AND OTHER GOOD AND VALUABLE CONSIDERATIONS, THE RECEIPT OF WHICH IS HEREBY ACKNOWLEDGED, l/WE, ZACHARY J. BARBER AND TIFFANY J. BARBER, HUSBAND AND WIFE, HEREINAFTER CALLED THE GRANTOR, HAVE BARGAINED AND SOLD, AND BY THESE PRESENTS DO TRANSFER AND CONVEY UNTO ROBERT PAUL RUSSELL AND NICOLE DANIELLE RUSSELL, HUSBAND AND WIFE, HEREINAFTER CALLED THE GRANTEE, THEIR HEIRS AND ASSIGNS, A CERTAIN TRACT OR PARCEL OF LAND IN WILLIAMSON COUNTY, STATE OF TENNESSEE, DESCRIBED AS FOLLOWS, TO-WIT: 39 Watertree Ct (ADDRESS) 39 Watertree Ct (ADDRESS) Parcel ID(s): 159-011.04 (IN GREENBELT) Robert Paul Russell and Nicole Danielle Russell Robert Paul Russell and Nicole Danielle Russell THIS INSTRUMENT WAS PREPARED BY Mid-State Title & Escrow, Inc. 128 Holiday Ct., Ste. 125, Franklin, TN 37067 (*enss Affiant z0""M4, I \ I PUBLIC — I NvyooK TX 77380 (STATE) (ZIP) Notary Public . MY COMMISSION EXPIRES: | Opi (AFFIX SEAL) C) TX 77380 (STATE) (ZIP) Book 9821 Page 515 Thence. South 89 degrees 49 minutes 32 seconds East, a distance of 310.49 feet to an iron rod found; Thence. South 70 degrees 35 minutes 10 seconds East, a distance of 236.69 feet to an iron rod set; Thence. North 75 degrees 43 minutes 42 seconds East, a distance of 541.37 feet to an iron rod set; Thence. North 80 degrees 43 minutes 31 seconds West, a distance of 122.94 feet to an iron rod found at the northeast corner of property conveyed to Michael Ruggiero etux Renee as of record Deed Book 1580, Thence, following the north boundary of Caukin and Tomlin, South 73 degrees 13 minutes 43 seconds West, a distance of 197.64 feet to an iron rod set; Thence, South 79 degrees 53 minutes 25 seconds East, a distance of 775.94 feel to an iron rod found at the southeast corner of Benning property and on the south boundary of property conveyed to Dennis P. Milnar etux Constance J. as of record in Warranty Book 77, Page 176, in the Register's Office of Rutherford County, Tennessee; Thence, South 79 degrees 52 minutes 43 seconds East, a distance of 13.07 feet to an iron rod set at the true Point of Beginning; Thence, continuing with the south boundary of Benning, South 79 degrees 52 minutes 43 seconds East, a distance of 205.66 feet to an iron rod found: Thence, leaving Swafford boundary and following the west and south boundaries of Benning, South 08 degrees 27 minutes 20 seconds West, a distance of 185.18 feet to an iron rod set; Thence, South 79 degrees 53 minutes 34 seconds East, a distance of 1,019.00 feet to an iron rod set on the west boundary of property conveyed to Thomas R. and Donna P. Benning as of record in Deed Book 5060, Page 718, in the Register's Office of Williamson County. Tennessee, said rod being the southeast comer of said Swafford property; Thence, following said east margin of Taliaferro Road, North 12 degrees 06 minutes 18 seconds West, a distance of 255.98 feet to an iron rod set at the southwest comer of property conveyed to William S. and Laura F. Swafford as of record in Deed Book 7520, Page 170, in the Register's Office of Williamson County, Tennessee, said rod being the northwest corner of the herein described property: Being an eastern 49.13-acre portion of the Martha N. and Thomas E. Stacy property that is described in Deed Book 3925, Pages 754-755, in the Register's Office of Williamson County, Tennessee and shown as Part Of Parcel 159-011.03 on Williamson County Tax Maps, and more particularly described as follows: Thence. South. 19 degrees 44 minutes 07 seconds East, a distance of 778.05 feet to a fence post on the north boundary' of property conveyed to Jack W. Caukin and Charles W. Tomlin as of record in Deed Book 1968, Page 1835, in the Register's Office of Rutherford County, Tennessee; Thence, following south boundary of Milnar, South 80 degrees 50 minutes 21 seconds East, a distance of 1,337.20 feet to a fence post; Thence, leaving said east margin and following the south boundary of Swafford property, South 79 degrees 05 minutes 56 seconds East, a distance of 420.24 feet to an iron rod found; Commencing at an iron rod set on the east margin of Taliaferro Road at a cedar tree at the northwest comer of property conveyed to Tommy and Natalie Henley as of record in Deed Book 5409. Page 433, in the Register's Office of Williamson County, Tennessee, said rod being the southwest corner of the herein described property; Book 9821 Page 516 Page 2695, in the Register's Office of Rutherford County, Tennessee; Thence, South 00 degrees 11 minutes 25 seconds East, a distance of 199.90 feet to an iron rod found: Thence. North 43 degrees 12 minutes 00 seconds West, a distance of 302.37 feet to an iron rod set; Containing 2,140,267 square feet of 49.13 acres. Thence, following the north boundary of Ruggiero and the north boundary- of the aforementioned Henley property. North 86 degrees 01 minutes 40 seconds West, a distance of 2,036.49 feet to an iron rod found; TO HAVE AND TO HOLD the said tract or parcel of land, with the appurtenances, estate, title and interest thereto belonging to the said GRANTEES, their heirs and assigns forever; and we do covenant with the said GRANTEES that we are lawfully seized and possessed of said land in fee simple, have a good right to convey it and the same is unencumbered, unless otherwise herein set out; and we do further covenant and bind ourselves, our heirs and representatives, to warrant and forever defend the title to the said land to the said GRANTEES, their heirs and assigns, against the lawful claims of all persons whomsoever. Wherever used, the singular number shall include the plural, the plural the singular, and the use of any gender shall be applicable to all genders. Being a portion of the same property conveyed to Martha N. Stacy and Thomas E. Stacy by Quitclaim Deed from Frank Latimer and his wife, Cynthia Latimer of record in Book 3925, Page 754, in the Register's Office for Williamson County, Tennessee, dated May 24, 2006 and recorded on May 31, 2006 and in Book 627, Page 3430, in the Register's Office for Rutherford County, Tennessee, dated May 24, 2006 and recorded on June 5, 2006. Thence, leaving said north boundary of Henley and following a new line through the parent parcel, North 00 degrees 02 minutes 32 seconds WEST, a distance of 993.21 feet to the Point of Beginning. Being the same property conveyed to Zachary J. Barber and Tiffany J. Barber, husband and wife by Warranty Deed from Martha N. Stacy and Thomas E. Stacy, married to each other of record in Book 9162, Page 90, in the Register's Office for Williamson County, Tennessee, dated December 08, 2022 and recorded on December 13, 2022, and also of record in Book 2305, Page 1276, in the Register's Office for Rutherford County, Tennessee, recorded on December 13, 2022. Deed of Correction of record in Book 9213, Page 390, in the Register's Office for Williamson County, recorded on March 15, 2023, and also of record in Book 2326, Page 1043, in the Register's Office for Rutherford County, Tennessee, recorded on March 15, 2023. Subject to: This conveyance is subject to the matters set forth below, if any, as well as any and all zoning regulations, building restrictions, setback lines, conditions, covenants, and restrictions (as may be amended or supplemented), all easements, utility easements or rights of ways for public utilities that appear in the appropriate public records. Property taxes have been prorated and the Grantee has assumed payment thereof when same become due and payable. Taxes for the year 2025, a lien not yet due and payable. TOGETHER WITH a 25' access easement for ingress/egress as shown on the plats of record in Plat Book 44, Page 104, Plat Book 42, Page 114, and Plat Book 31, Page 103, in the Register's Office for Williamson County, Tennessee. unimproved 0 This is improved • property, known as 0 Bo Lane / Taliaferro Road, Eagleville, TN 37060________ (House No.) (Street) (P.O. Address) (City or Town) (Postal Zip) Book 9821 Page 517 ,2025.day of , 2025, before me personally appeared Zachary J. Barber and 2- Tiffany J. Barber, to me known t^be the person (or persons) described in and who executed the foregoing instrument, and acknowledged that such person (or persons) executed the same as such person (or person's) free act and deed. Notary Public uqll / . "blic 8 J SA -00* <,M fkvon CoR ' YSt tUVV 915546 64, oltW, / State % • ' , or ' 2 s Onnes3.. ) £ NVotar j = My Commission Expires: 3 23 2 7 Witness our hands this 0- _= 6-- Zachary J. Barber 0/ 3 Be "977J 0er STATE OF TENNESSEE COUNTY OF WILLIAMSON On this &+ day of ( Book 9821 Page 518 True Copy Certification Affiant Signature &X , 2025 / 2025. - . A <- 25029001 State of Tennessee County of Williamson I, Yvette Meldrum, do hereby make oath that I am a licensed attorney and/or the custodian of the original version of the electronic document tendered for registration herewith and that this electronic document is a SHERRY ANDERSON REGISTER OF DEEDS BK/PG: 9821/514-518 25029001 0.00 2183.00 25.00 2.00 1.00 2211.00 IAMSON COUNTY State . i fonnessec Notary . Public , true and exact copy of the original document executed and authenticated according to law on WMJ QX_____2025. (L (77 " 1 „d26l/19/) 3* q SWs , $ 620 7s. 5 PGS : DEED ELIZABETH LYNCH 1062855 09/08/2025 - 11:28:33 AM MORTGAGE TAX TRANSFER TAX RECORDING FEE DP FEE REGISTERS FEE TOTAL AMOUNT STATE OF TENNESSEE, WI maenoo ‘ 5 4/ i 11 i V * " MY COMMISSION EXPIRES; 300 0 7 Sworn to and subscribed before me this O% of 22122 Notary's Signature' " EXHIBIT 5 Prepared For McMahon's Steel Erections LLC Description TotalRate $150,000.00 Subtotal $150,000.00 Total $150,000.00 Zach McMahon Paul Russell Bo Lane Widening Approx 3200 Linear ft x 4’ MCMAHONS STEEL ERECTIONS EXTERIOR EXCELLENCE Estimate # Date Paul Russell (270) 210-2039 138 Dalton Cir Hendersonville, Tn 37075 Phone: (615) 663-4731 Email: zachmcmahon@rocketmail.com Water Line relocation where pertinent Fence relocation where necessary Culvert pipes to support the wider road Excavation of new drainage ways 3-4" rock base approximately 10" 10" crusher run 1379 07/29/2026 Pa: 1 $150,000.00 $150,000.00 EXHIBIT 6 G P 15 April 2026 Williamson County Planning Office Re: Variance Request — Bo Lane, Williamson County (Fire Service Access) TI: BZA Members Background and Inspection Decision and Conditions <0 Because of the existing conditions and the serious safety risks they pose to emergency responders and the public, I again declined to grant a fire-access variance. • The property owner then proposed providing a 12-foot-wide travelway with intermittent pull- offs. I indicated that such a plan would be acceptable in principle but that I would not grant a variance until the improvements were completed and physically in place ("on the ground"). I declined the variance based on that report. At the owner's request, I personally inspected the road two days later. • During my inspection I observed that Bo Lane is a narrow gravel road with deep ditches on both sides and numerous deep ruts and potholes along the access. Although the road widens in a few locations, the presence of the ditches leaves virtually no safe area for a fire apparatus to pull off to allow another emergency vehicle to pass. I am writing to put in writing my observations, conclusions, and concerns regarding the Bo Lane area of rural Williamson County and the recent request for a fire-access variance for a proposed residential building on that road. • At the request of a new property owner seeking a variance from the Fire Service, I initially directed a fire captain to inspect Bo Lane. The captain reported the road to be in poor condition. Williamson Fire/Rescue J.R.Bonson, Coordinator 304 Beasley Drive Franklin, Tennessee 37064 (615) 790-5757 Office (615) 417-9241 Cell Jav.Bonson@WilliamsonCounty-In.gov SB “adamass,” Safety Concerns and Precedent Availability for Further Information Respectfully, J.R. Bonson Please feel free to contact me at [phone number] or [email address] for any additional information or to arrange a follow-up inspection. • I regret that I cannot present this letter in person; I am traveling on business this week. A colleague from the Fire Service is available to provide further clarification regarding emergency traffic and operational concerns if needed. • I expressed empathy for the property owner's situation and suggested it would be equitable for neighbors or county government to share in the cost of required improvements rather than placing the entire financial burden on a single property owner. • I also informed the owner that, within weeks of my initial visit, a nearby residential structure fire suffered a complete loss in part because of access issues and inconsistent water delivery attributable to a similar access road. I personally observed a Rutherford County fire apparatus nearly overturn while negotiating that road. These events underscore the genuine danger posed to firefighters and other emergency personnel when access and apparatus operations are compromised. COLLECTIVE EXHIBIT 7 Photo 2Regulatory Constraints (No ability to modify road in these areas without additional regulatory approvals) (Dotted red line representing approximate portion of Bo Lane where fee ownership of land along the northern and southern borders is owned by others) Aerial View of Bo Lane and Approximate Property Line Photo 1 .a Oas Photo 3 Constraints Applicable to Both Sides of Bo Lane (Stream crossing) MEs Jha.aH (Local utility poles) i Photo 4 Photo 5 (Drainage features and ditches) (Private water meter for 3 private water lines running alongside southern edge of Bo Lane) Additional Constraint Applicable to Southern Side of Bo Lane Photo 6 fife fEha ‘8-7 p s en tir ‘ass Photo 8 (Mature vegetation) (Neighbor’s existing barn along northern edge of Bo Lane) Additional Constraints Applicable to Northern Side of Bo Lane Photo 7 (Neighbor's livestock fencing) p r noio y —esi1 isar - s d —a f - Photo 10 (Start of Bo Lane off of Taliaferro Road) Photo 11 (Driveway to subject property) .95 ■ =- -Cde ■ eoe Pg-se. - e . se — . •• - ■ Item 14—Page 1 of 1 Reviewer: AVH Date: 8/13/2026 ITEM 14 SITE PLAN REVIEW FOR CREWS RUNWAY , ON 1,137.13 ACRES LOCATED OFF BOY SCOUT ROAD IN THE 1ST VOTING DISTRICT (5-2026-004). Attachment 14-1 Site Plan 14-2 Aerial Photograph 14-3 Staff Report for BZA Meeting of June 2026 Area 1,137.13 acres Zoning Rural Preservation-5 (RP-5) Water HB&TS Utility District Development Option Private Landing Strip Chapter 1101 Status Rural Maps and Parcels 074---1.03, 1.04, 1.06, 1.07 and 1.08 094---033.03 095---018.03 File Number (5-2026-004) In June 2026 the Board of Zoning Appeals (BZA) granted a Special Use Permit to allow a Private Landing Strip that is accessory to a residential use on the property in question , and a Variance to allow disturbance of slopes in excess of twenty -five (25) percent in order to construct the private landing strip . The applicant is now requesting Site Plan approval for the runway and the runway’s associated buildings. This new runway will replace an existing 1,800 -foot grass runway, which will be allowed to return to its natural state and be used as a hay field. According to the Site Plan, the runway will measure 3,000 feet in length and be sixty-five (65) feet in width. The r unway will be paved, and the applicant proposes to construct a 10,000 - square foot hanger for storage of the two (2) aircraft that will utilize the property, a 1,600-square foot storage building, and a 336 -square foot fuel shed. There will be no commercial use of the runway. It should be noted there are seven (7) separate parcels that make up the subject properties and will be consolidated into a single property via a newly recorded deed. The Williamson County Department of Sewage Disposal Management has r eviewed the application and approved the request. Primary access to the proposed runway is via an easement through the County’s Landfill, and the Tennessee Department of Transportation has granted conceptual approval for access onto Pinewood Road for this use. A Photometrics Plan and a Landscaping Plan with the appropriate buffers have been submitted and approved. The Site Plan is in order, and Staff recommends approval. COVER C-0.0 LOCATION MAP 1" = 3,000' SITE PLAN FOR CREWS PROPERTY PRIVATE AIRSTRIP RUNWAY MAP 074, PARCELS 1.02, 1.03, 1.04, 1.06, 1.07, 1.08 MAP 094, PARCEL 33.02 AND MAP 095, PARCEL 18.03 WILLIAMSON COUNTY, TENNESSEE SITE DEVELOPER: CHARLES CREWS 5600 BOY SCOUT ROAD ENGINEER: T-SQUARE ENGINEERING 111 SOUTHEAST PARKWAY CT FRANKLIN, TN 37064 SHEET SCHEDULE C-0.0 COVER SHEET C-1.0 OVERALL EXISTING CONDITIONS C-2.0 OVERALL SITE PLAN C-2.1 DETAILED SITE PLAN / GRADING C-2.2 PLAN AND PROFILE C-3.0 INITIAL AND TEMPORARY EROSION CONTROL PLAN C-3.1 PERMANENT EROSION CONTROL PLAN C-3.2 EROSION CONTROL DETAILS C-4.0 PREDEVELOPMENT STORMWATER PLAN C-4.1 POSTDEVELOPMENT STORMWATER PLAN C-8.0 DETAIL SHEET DATE T-SQUARE drawn by: as shown scale: 7/20/26 date: NO. REVISIONS NSM reviewer: SroMect sheet T-SQUAREENGINEERING APPLICANT T-SQUARE ENGINEERING 111 SOUTHEAST PARKWAY COURT FRANKLIN, TN 37064 615.678.8212 CREWS RUNWAY 5600 BOY SCOUT ROAD WILLIAMSON COUNTY, TENNESSEE OWNER OF RECORD CHARLES AND KIMBERLY CREWS 555 GREAT CIRCLE ROAD NASHVILLE, TN 37228 MAP 074, PARCELS 102, 103, 104, 106, 107, 108 MAP 094, PARCEL 33.02 AND MAP 095, PARCEL 1803 23-0342 7/20/2026 FLOOD NOTE A PORTION OF THIS PROPERTY IS LOCATED IN AN AREA DESIGNATED AS "ZONE AE" AS EVIDENCED ON FEMA PANEL # 47187C0165F OF WILLIAMSON COUNTY, TN, DATED 09/29/2006. NOTE: THE WILLIAMSON COUNTY BOARD OF ZONING APPEALS GRANTED A SPECIAL USE PERMIT FOR THE PRIVATE LANDING STRIP; THEY ALSO GRANTED A VARIANCE ALLOWING FOR DISTURBANCE OF STEEP SLOPES ON JUNE 25, 2026. P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 0 Cover Sheet.dwg, 7/20/2026 12:40:56 PM ATTACHMENT 14-1A PC 12 OVERALL SITE PLAN C-2.0 DATE T-SQUARE drawn by: as shown scale: 7/20/26 date: NO. REVISIONS NSM reviewer: SroMect sheet T-SQUAREENGINEERING CREWS RUNWAY 5600 BOY SCOUT ROAD WILLIAMSON COUNTY, TENNESSEE 23-0342 7/20/2026 ( IN FEET ) GRAPHIC SCALE 0 500 1000500 250 SCALE: 1" = 500' 100 YEAR FLOOD PLAIN APPROXIMATE LOCATION PER FEMA FLOOD PLAIN PANEL NOTED ABOVE 200FT FROM EDGE OF RUNWAY 1,000FT FROM EDGE OF RUNWAY 1,000FT FROM EDGE OF RUNWAY WILLIAMSON COUNTY LANDFILL (NON-RESIDENTIAL) NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL 200FT FROM EDGE OF RUNWAY P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 2 Site Plan.dwg, 7/20/2026 12:54:46 PM ATTACHMENT 14-1B 920 860 870 880 890 900 910 920 880 890 900 910 870 880 890 900 910 870 880 890 900 910 910 920 920 910 910 900 910 900 910 900 910 890 900 840 850 860 870 880 920 930 890 900 920 930 890 900 910 850 860 870 880 910 920 920 860 870 880 890 900 910 920 920 850860870880890900910 850 860 870 880 890 900 910 910 910 910 910 890 900 850 860 870 880 890 900 860 870 880 890 900 840 850 860870 880 890 900 860 870 880 890 900 910 840 850 860 870 880 890 900 910 920 890 900 910 920 BP: 0+00.00 EP: 40+00.00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00 870 880 890 900 910 910 912 914 920 924924 860 870 880 890 900 910 920 920 910 920 904 906 908 912 914 916 918 PC 12 900 910 910 920 910 920 910 920 910 910 920 900 910 920 930 886 888 890 892 894 896 898 900 902 904 906 908 910 908 910912 914 916 918 920 922 924 926 31+00 32+00 33+00 34+00 35+00 PC 12 ST-HW4 INV OUT: 894.49 102' of 18" RCP @ 1.00% ST-HW3 INV IN: 895.50 900 910 896 898 902 904 906 908 900 910 898 902 904 906 908 912 914 916 910 920 906 908 912 914 916 918 922 924 926 910 920 904 906 908 912 914 916 918 910 920 904 906 908 912 914 916 918 922 924 926 904 904 906 -1.0% 904.00 904.00 -1.2%-2.0% -1.0% DATE T-SQUARE drawn by: as shown scale: 7/20/26 date: NO. REVISIONS NSM reviewer: SroMect sheet T-SQUAREENGINEERING CREWS RUNWAY 5600 BOY SCOUT ROAD WILLIAMSON COUNTY, TENNESSEE 23-0342 7/20/2026 ( IN FEET ) GRAPHIC SCALE 0 250 500250 125 SCALE: 1" = 250' DETAILED SITE PLAN / GRADING C-2.1 ( IN FEET ) GRAPHIC SCALE 0 30 6030 15 SCALE: 1" = 30' SEE INSET RIGHT 12FT X 28FT FUEL SHED 100FT X 100FT HANGAR 10,000 SF PARKING PRIVATE INGRESS/EGRESS PRIVATE INGRESS/EGRESS 16FT GRAVEL ROAD 16FT GRAVEL ROAD RUNWAY (65FT X 3,000FT) 200FT FROM EDGE OF RUNWAY 200FT FROM EDGE OF RUNWAY 1000FT FROM EDGE OF RUNWAY 1000FT FROM EDGE OF RUNWAY NOTES: 1) THE PROPOSED USE FOR THIS SITE IS: AIRPORT, LANDING STRIP, PRIVATE 2) CURRENT ZONING OF ALL PROPERTY: RURAL PRESERVATION - 5 3) NO HELIPORT WILL BE CONSTRUCTED; NO HELICOPTERS WILL BE USED ON THIS SITE 4) THERE IS AN EXISTING GRASS RUNWAY ON 5600 BOY SCOUT ROAD THAT WILL BE ABANDONED UPON COMPLETION OF THE NEW RUNWAY 5) ALL STRUCTURES/HANGARS ARE TO BE 100FT FROM ANY PROPERTY LINE 6) THE ENDS OF THE RUNWAY ARE TO BE 1000FT FROM ANY PROPERTY LINE; THE SIDES OF THE RUNWAY ARE TO BE 200FT FROM ANY PROPERTY LINE. NO AIRCRAFT WILL BE HANGARED, TIED DOWN OR PARKED WITHIN THE SETBACKS 7) THE MAX HEIGHT OF THE STRUCTURES ON THE PROPERTY SHALL BE SUBJECT TO FEDERAL AVIATION ADMINISTRATION, PART 77 8) NO COMMERCIAL ACTIVITY WILL BE CONDUCTED IN CONJUNCTION WITH THIS RUNWAY 9) OWNER TO ABANDON THE EXISTING GRASS RUNWAY AFTER COMPLETION OF THIS PROPOSED RUNWAY; GRASS RUNWAY TO BE CONVERTED TO HAY FIELD 10) TWO (2) AIRCRAFTS WILL BE PARKED ON THE SITE.; ONE (1) AIRCRAFT WILL BE PARKED ON THE APRON, AND ONE (1) WILL BE PARKED INSIDE THE HANGAR. 40' 100' 120' 102.3' 334.5' CONCRETE LINED DITCH WHERE APPLICABLE AIRSTRIP PAVEMENT TO BE IN ACCORDANCE WITH GEOTECHNICAL ENGINEER AND/OR FAA SPECIFICATIONS STORAGE 1,600 SF 500' SAFETY APPROACH; GRASS 500' SAFETY APPROACH; GRASS WILLIAMSON COUNTY LANDFILL (NON-RESIDENTIAL) NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL NO RESIDENTIAL STRUCTURE LOCATED ON PARCEL 200' 423' 1000' 1000' HEAVY DUTY CONCRETE SECTION HEAVY DUTY ASPHALT SECTION 69.1' 200' 70' 192' 52' 100' 50' WATERWAYNATURAL AREA 25' DRAINAGEWAYEASEMENT 50' WATERWAY NATURAL AREA 25' DRAINAGEWAY EASEMENT 25' DRAINAGEWAY EASEMENT TYPICAL SECTION N.T.S. 32.5'32.5' 3:1 SLOPE 3:1 SLOPE 279' 1127' P:\Projects\2023\23-0342 (Crews Runway - Jason Goddard)\Production\23-0342 2 Site Plan.dwg, 7/20/2026 12:41:32 PM ATTACHMENT 14-1C ATTACHMENT 14-3 Item 3--Page 1 of 3 Reviewer: AVH Date: 9-26-2024 ITEM 6 A REQUEST BY NATHAN MCVEY OF T -SQUARE ENGINEERING (CHARLES CREWS, PROPERTY OWNER) FOR A SPECIAL USE TO ALLOW A PRIVATE LANDING STRIP AND A VARIANCE FOR A DISTURBANCE OF STEEP SLOPES. THE PROPERTIES ARE LOCATED AT 5600 BOY SCOUT ROAD (MAP 74, PARCELS 1.02, 1.03, 1.04, 1.05, 1.06, 1.07 AND 1.08, MAP 94, PARCEL 33.02, AND MAP 95, PARCEL 18.03), ARE ZONED RURAL PRESERVATION-5 (RP -5) AND LOCATED IN THE 1 ST VOTING DISTRICT (5-2026-004) Attachment 6-1 Site Plan 6-2 Aerial Photograph 6-3 Site Photographs 6-4 Letter of Intent 6-5 Minutes from January 2001 Planning Commission Meeting 6-6 Section 5.01: Special Uses 6-7 Section 11.04 (D)(16): Landing Strip and Helipad, Private 6-8 Section 5.02: Variances 6-9 Section 13.03 (B): Steep Slopes 6-10 Applicant’s Slope Exhibit Area 1,190 acres Zoning Rural Preservation-5 (RP-5) Water HB&TS Utility District Development Option Private Landing Strip Chapter 1101 Status Rural Maps and Parcels 074---1.02, 1.03, 1.04, 1.05, 1.06, 1.07 and 1.08 094---033.03 095---018.03 File Number (5- 2026-004) In January 2001 the Williamson County Regional Planning Commission granted a Conditional Use Permit to allow a Private Landing Strip on a portion of this property which totals approximately 186 acres (See Attachment 6 -5). The applicant has resided on the property and operated the 1,800-foot grass runway on since that time. In November of 2025 the County Commission revised the Zoning Ordinance to allow private landing strips such as this. The applicant is requesting approval of a private landing strip that is accessory to a residential use in order to relocate the existing runway to a more suitable location. According to the Site Plan and Letter of Intent, the runway will measure 3,000 feet long, be sixty-five (65) feet in width, and will replace the existing 1,800-foot runway (See Attachment 6-4). The runway will be paved, and the applicant proposes to construct a 10,000- square foot hanger for storage of the two (2) aircraft that will utilize the property, a 1,600-square foot storage building, and a Item 6—Page 2 of 3 Reviewer: AVH BZA Date: 6-25-2026 336-square foot fuel shed. The existing runway will be allowed to return to its natural state and be used as a hay field. There will be no commercial use of the runway. It should be noted there are nine (9) separate parcels that make up the subject proper ties, and it will be necessary for those properties to be consolidated into a single property via a newly recorded deed. The recordation of this new deed has been made a condition of approval. The Williamson County Department of Sewage Disposal Management has reviewed the application and approved the request. Primary access to the proposed runway is via an easement through the County’s Landfill , and the Tennessee Department of Transportation has granted conceptual approval for access onto Pinewood Road for this use. The proposed use will comply with the Zoning Ordinance so long as the nine (9) parcels are consolidated into a single parcel, and the Board finds in its evaluation that the standards of Section 5.01 have been met. A Landscaping Plan with the appropriate buffers shown is under review by Staff. Outside of the lighting requirements of the Federal Aviation Administration (FAA), the runway will not be illuminated, and therefore a Photometrics Plan is not required. Section 5.01 of the Zoning Ordinance outlines the Board’s responsibilities while reviewing Special Uses, and Subsection E outlines the Review Standards that should be considered when evaluating Special Uses (See Attachment 6-6). During its deliberations, the Board will need to make a finding as to whether the proposed Private Landing Strip meets the standards of Section 5.01(E) of the Zoning Ordinance. The Site Plan (See Attachment 6-1) included in the packet is for illustrative purposes only and is under review for compliance. As the total square footage of all proposed buildings is greater than 5,000 square feet, the Planning Commission will review the Site Plan. The Board must determine if the use is appropriate in this location based on the standards outlined in the following sections: 1.) Section 5.01 (E); and 2.) Section 11.04 (D)(16) of the Zoning Ordinance. In order to construct the runway, the applicant will disturb slopes in excess of twenty-five (25) percent. The Zoning Ordinance defines slopes in excess of twenty-five (25) percent as Very Steep Slopes, and Section 13.03 (B)(5): General Prohibition of Land Disturbance prohibits clearing, excavation, and grading, among others, on Very Steep Slopes (See Attachment 6- 9). The applicant is requesting a variance from the aforementioned Section in order to construct the runway. Attachment 6-10 illustrates the locations of the Very Steep Slopes that will be disturbed in order to construct the runway. Staff recommends approval of the Special Use with the following stipulations: 1.) Recording of a deed consolidating the nine (9) properties that make up the subject properties; Item 6—Page 3 of 3 Reviewer: AVH BZA Date: 6-25-2026 2.) Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; 3.) Submittal to and approval by the County Engineer of both the stormwater calculations and the grading and drainage plan; and 4.) All signage must be approved per Ordinance requirements. Variances are subject to the provisions delineated in Article 5, Section 5.02 of the Zoning Ordinance (See Attachment 6 -8), and more specifically, the standards outlined in Section 5.02(F). Item 15—Page 1 of 1 Reviewer: OCW Date: 8/13/2026 ITEM 15 SITE PLAN REVIEW FOR WYELEA FARMS – THE S TABLES, ON 53.70 ACRES LOCATED OFF DEL RIO PIKE IN THE 9TH VOTING DISTRICT (5-2026-005). Attachment 15-1 Site Plan 15-2 Aerial Photograph Area 53.70 acres Zoning Rural Development – 5 (RD-5) Water City of Franklin Sewer Nontraditional Wastewater Treatment and Disposal System Development Option Country Club Chapter 1101 Status Rural File Number (5-2026-005) The applicant is requesting Site Plan approval for the Wyelea Farms Stables , which is classified as a Country Club. As the Stables are larger than 5 ,000 square feet, it is considered a Major Site Plan and requires Planning Commission approval. Because the Stables are proposed to be located within required Open Space, the Homeowner’s Association must maintain ownership of the Stables. The facilities, which are located in Open Space, consist of a Club House, Stables, Sheds, Warehouse, Maintenance Building, and an Indoor Riding Arena. The requirements of Section 11.03 (D)(21) have been met. A Landscaping Plan has been submitted and approved by Staff. A water bond is not required , as the Stables was included in Section 1. The Site Plan is in order, and Staff recommends approval with the following conditions: 1. Per the recommendation of the County’s Wastewater Consultant, the posting of a Performance Bond for the Collection System in the amount of $ 242,000; and 2. The Homeowner’s Association must maintain ownership of the Stables; and 3. Execution of a Performance Agreement for the above referenced sureties. WYELEA FARMS THE STABLES 3021 DEL RIO PIKE WILLIAMSON COUNTY, TN 37069 C0.00 DESCRIPTION INDEX OF DRAWINGS COVER SHEETC0.00 C0.01 C9.01 SITE DETAILS LEGEND & NOTES SHEET NO. OVERALL SITE PLAN SITE PLAN EROSION CONTROL PLAN UTILITY PLAN EXISTING CONDITIONS PLAN GRADING & DRAINAGE PLAN C1.00 C3.00 C4.00 C5.00 C6.00 C2.00 DETAILED UTILITY PLANC6.11 C4.10 COVER SHEET PROJECT SITE © 2025 Collected Civil Engineering, LLC All rights reserved. copy or reproduction of this drawing or document, or any portion thereof, without the express written permission of Collected Civil Engineering, LLC. is prohibited. This drawing or document is not intended or represented to be suitable for any purpose other than the specific project, application and situation for which it was intended. Any modification of this drawing or document, or any use for any project, application or situation other than that for which it was intended, will be at user's sole risk and without liability to Collected Civil Engineering, LLC. Except as provided by rule 0120-02-.08(5)(b) of the Tennessee state board of architecture and engineering examiners, any changes made to this drawing or document, after final revision and sealing by the registrant are prohibited by any person other than the profession registrant, including but not limited to owners/clients, contractors, subcontractors, other design professional or any of their agents, employees or assigns. DRAWING NAME: DRAWING NUMBER: WYELEA FARMS THE STABLES 3021 DEL RIO PIKE WILLIAMSON COUNTY, TN 37069 7/20/2026 2:54:54 PM K:\Public-Collected Civil\02_Projects\24001-24999\24020 - Wyelea Residential\24020.04 - Equestrian Center\02_DWG\C0.00_COVER.dwg This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Collected Civil Engineering, LLC. shall be without liability to Collected Civil Engineering, LLC. Tennessee811 KNOW WHAT'S BELOW. CALL BEFORE YOU DIG 921B Woodland Street Nashville, TN 37206 COLLECTED CIVIL ENGINEERING DATE: PROJECT NUMBER: 24020.04 DRAWN BY:REVIEWED BY: PR SCALE: ISSUED FOR: NORTH ARROW: PM LAND DISTURBANCE PERMIT NO:DATE:DESCRIPTION: REVISIONS 1 7/1/26 7/20/26 RESPONSE TO REGULATORY COMMENTS 7/20/26 LOCATION MAP 1"=5000' PROJECT DESCRIPTION THE CONSTRUCTION OF THE THE STABLES OF THE WYELEA FARMS DEVELOPMENT INCLUDING A CLUB HOUSE, STABLES, SHEDS, WAREHOUSE, MAINTENANCE BUILDING, INDOOR ARENA, AND SURFACE PARKING. THE SCOPE OF WORK INCLUDES GRADING, DRAINAGE, PAVING/HARDSCAPE, AND ALL ASSOCIATED UTILITY CONNECTIONS FOR THE PROPOSED BUILDINGS. SURVEY BASE MAP INFORMATION TAKEN FROM A TOPOGRAPHIC, UTILITY AND BOUNDARY SURVEY PREPARED BY WILSON & ASSOCIATES, P.C. DATED 6/23/23. COLLECTED CIVIL ENGINEERING, LLC AND ANY OF THEIR CONSULTANTS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR OMISSIONS RESULTING FROM THE AFOREMENTIONED SURVEY. NPDES GENERAL PERMIT TNR100000 COMPLIANCE NOTES: 1. THE WYELEA FARMS - THE STABLES PROJECT AREA IS INCLUDED IN THE ISSUED CONSTRUCTION GENERAL PERMIT (CGP) FOR THE OVERALL DEVELOPMENT INFRASTRUCTURE WORK (TNR247592, EFFECTIVE 07/30/2024, EXPIRES 09/30/2026). 2. THE TOTAL AREA OF DISTURBANCE PLANNED FOR THIS PORTION OF THE PROJECT IS 53.702 ACRES. 3. ONCE STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITIES HAVE BEEN ELIMINATED AND THE PERMITTED AREA ACHIEVES A UNIFORM 70% PERMANENT VEGETATIVE COVER, OR HAS EQUIVALENT MEASURES (RIPRAP, GEOTEXTILE, ETC.), IN AREAS NOT COVERED WITH IMPERVIOUS SURFACES, THE NOT (NOTICE OF TERMINATION) CAN BE SUBMITTED TO TDEC FOR TERMINATION OF COVERAGE AND TEMPORARY EROSION & SEDIMENT CONTROLS CAN BE REMOVED. ELIMINATION OF STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY MEANS ALL DISTURBED SOILS HAVE BEEN FULLY STABILIZED, THE TEMPORARY EROSION & SEDIMENT CONTROLS HAVE BEEN REMOVED, AND/OR SUBSEQUENT OPERATORS HAVE OBTAINED PERMIT COVERAGE. 4. SITE DISTURBING 1 ACRE OR LARGER SHALL HAVE TWICE WEEKLY INSPECTIONS BY A TDEC LEVEL I CERTIFIED PERSON. 5. PLEASE REVIEW THE NPDES GENERAL PERMIT FOR RULES AND REGULATIONS REGARDING CONSTRUCTION ACTIVITY. PROJECT NOTES: 1. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORMWATER MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN. 3. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT. 4. ALL ROADWAYS WITHIN THE DEVELOPMENT WILL BE PRIVATE. 5. THE DEVELOPER HAS UTILIZED REASONABLE MEANS TO NOTIFY THE OPERATOR OF THE NATURAL GAS TRANSMISSION PIPELINE TO VERIFY THE LOCATION OF THE PIPELINE AND THE PIPELINE EASEMENT. THE DEVELOPER HAS REVIEWED, OR ATTEMPTED TO REVIEW, PRELIMINARY INFORMATION ABOUT THE PROPOSED DEVELOPMENT WITH THE PIPELINE OPERATOR. 6. THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS AND RIDGETOPS, SLIPPAGE SOILS, AND KARST FEATURES. NONE OF THE MENTIONED FEATURES ARE PRESENT ON THIS SITE. 7. THE PROPOSED DEVELOPMENT WILL COMPLY WITH ALL REQUIREMENTS AND LIMITATIONS OF WILLIAMSON COUNTY ZONING ORDINANCE SECTION 16.02 (NOISE STANDARDS). SITE DATA TABLE ZONING: RURAL PRESERVATION (RP-5) MAP & PARCEL NUMBER: 051-01300 BOOK & PAGE NUMBERS:8799 / 670-676 TOTAL SITE ACREAGE: 580.45 Ac. THE STABLES (SECTION 1 PLAT O.S.3) ACREAGE: 53.702 Ac. PROPOSED USE (COUNTRY CLUB) CLUBHOUSE:2,476 SF STABLES (2 BLDGS W/ 24 STALLS EACH):20,657 SF MAINTENANCE & HAY STORAGE:2,502 SF INDOOR ARENA:22,000 SF OUTDOOR ARENA:45,294 SF SETBACKS (COUNTRY CLUB) 1. 100 FEET FROM THE RIGHT-OF-WAY OF EXISTING ROADS 2. 200 FEET FROM PROPERTY LINES OF SURROUNDING PARCELS 3. 300 FEET FROM EXISTING RESIDENTIAL DWELLINGS ON SURROUNDING PARCELS 4. WHEN THE COUNTRY CLUB IS PART OF A RESIDENTIAL DEVELOPMENT, THE SETBACK REQUIREMENTS IN 2 AND 3 ABOVE DO NOT APPLY TO PARCELS WITHIN THE DEVELOPMENT. UTILITY-POTABLE WATER CITY OF FRANKLIN, TN WATER MANAGMENT DEPT. 124 LUMBER DRIVE FRANKLIN, TN. 37064 P: (615) 794-4554 UTILITY-NATURAL GAS ATMOS ENERGY 200 NOAH DRIVE FRANKLIN, TN. 37064 P: (615) 485-6377 UTILITY-ELECTRIC MIDDLE TENNESSEE ELECTRIC 2156 EDWARD CURD LANE FRANKLIN, TN. 37067 P: (615) 465-5602 FIRE PROTECTION WILLIAMSON COUNTY STATION 14 405 DOWNS BLVD. FRANKLIN, TN. 37064 P: (615) 790-5821 UTILITY-WASTEWATER DESIGNER ADENUS UTILITIES GROUP 849 AVIATION PARKWAY SMYRNA, TN. 37167 P: (615) 220-7166 UTILITY-WASTEWATER OPERATOR TENNESSEE WASTEWATER 849 AVIATION PARKWAY SMYRNA, TN. 37167 P: (615) 220-7200 ARCHITECT PFEFFER TORODE ARCHITECTURE SCOTT TORODE 921B WOODLAND STREET NASHVILLE, TN 37206 P: (615) 667-0808 LAND SURVEYOR WILSON & ASSOCIATES, P.C. JOEY C. WILSON II, PE, RLS CONTACT: SEAN MCGOWAN, PE 108 BEASLEY DRIVE FRANKLIN, TN 37064 P: (615) 794-2275 PROJECT ENGINEER COLLECTED CIVIL ENGINEERING PETER ROMANO P.E. 921B WOODLAND STREET NASHVILLE, TN 37206 PETER@COLLECTEDCIVIL.COM P: (615) 917-0191 OWNER WEST HARPETH PARTNERS, GP 40 BURTON HILLS BLVD, SUITE 200 NASHVILLE, TN. 37215 DEED BK 8799, PAGES 670-676 DEVELOPER WYELEA DEVELOPMENT GROUP, LLC TREVOR CROSS 40 BURTON HILLS BLVD, SUITE 200 NASHVILLE, TN 37215 P: (615) 496-4121 LANDSCAPE ARCHITECT LANDDESIGN ERIC POHLMANN, PLA, ASLA, LEED AP 223 NORTH GRAHAM STREET CHARLOTTE, NC 28202 P: (704) 333-0325 FLOODPLAIN NOTE: ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM FLOOD INSURANCE RATE MAP (FIRM), WILLIAMSON COUNTY, TENNESSEE, COMMUNITY PANEL NUMBER #47187C0183H AND #47187C0184H DATED 12/20/2024, THIS PROJECT SITE CONTAINS REGULATED FLOODWAY, ZONE AE AND ZONE X. THE STABLES SITE IS CONTAINED WITHIN ZONE X, AREAS DETERMINED TO BE OUTSIDE THE 500-YEAR FLOODPLAIN. DETAILED DRAINAGE PLAN C4.20 DRAINAGE PLAN - STRUCTURE TABLE C9.00 SITE DETAILS C9.10 STORM SEWER DETAILS C9.11 STORM SEWER DETAILS C9.20 EROSION CONTROL DETAILS C9.30 UTILITY DETAILS DETAILED UTILITY PLANC6.10 ATTACHMENT 15-1A C3.00 SITE PLAN © 2025 Collected Civil Engineering, LLC All rights reserved. copy or reproduction of this drawing or document, or any portion thereof, without the express written permission of Collected Civil Engineering, LLC. is prohibited. This drawing or document is not intended or represented to be suitable for any purpose other than the specific project, application and situation for which it was intended. Any modification of this drawing or document, or any use for any project, application or situation other than that for which it was intended, will be at user's sole risk and without liability to Collected Civil Engineering, LLC. Except as provided by rule 0120-02-.08(5)(b) of the Tennessee state board of architecture and engineering examiners, any changes made to this drawing or document, after final revision and sealing by the registrant are prohibited by any person other than the profession registrant, including but not limited to owners/clients, contractors, subcontractors, other design professional or any of their agents, employees or assigns. DRAWING NAME: DRAWING NUMBER: WYELEA FARMS THE STABLES 3021 DEL RIO PIKE WILLIAMSON COUNTY, TN 37069 7/20/2026 2:55:22 PM K:\Public-Collected Civil\02_Projects\24001-24999\24020 - Wyelea Residential\24020.04 - Equestrian Center\02_DWG\C3.00_SITE.dwg This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Collected Civil Engineering, LLC. shall be without liability to Collected Civil Engineering, LLC. Tennessee811 KNOW WHAT'S BELOW. CALL BEFORE YOU DIG 921B Woodland Street Nashville, TN 37206 COLLECTED CIVIL ENGINEERING DATE: PROJECT NUMBER: 24020.04 DRAWN BY:REVIEWED BY: PR SCALE: ISSUED FOR: NORTH ARROW: PM LAND DISTURBANCE PERMIT NO:DATE:DESCRIPTION: REVISIONS 1 7/1/26 7/20/26 RESPONSE TO REGULATORY COMMENTS 7/20/26 1" = 70' SITE NOTES: USE TYPE & MAXIMUM OCCUPANCY: CLUB / LODGE2,489 SF, 17 PERSONS (CLUBHOUSE) WAREHOUSE20,480 SF, 42 PERSONS (STABLES) TOTAL OCCUPANCY59 PERSONS & 7 EMPLOYEES PARKING: REQUIRED OUTDOOR AMUSEMENT (1.0 SPACE PER FOUR (4) PEOPLE AT MAXIMUM OCCUPANCY + 1 SPACE PER 2 EMPLOYEES ON LARGEST SHIFT) MAX OCCUPANCY15 SPACES EMPLOYEES4 SPACES TOTAL REQUIRED19 SPACES PROVIDED STANDARD SPACES13 SPACES ACCESSIBLE SPACES2 SPACES EMPLOYEE PARKING4 SPACES TOTAL PROVIDED19 SPACES 7 8 4 ATTACHMENT 15-1B ATTACHMENT 15-2 Item 16—Page 1 of 1 Reviewer: AVH Date: 8/13/2026 ITEM 16 SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND DISPOSAL SYSTEM REVIEW FOR BR YNN SUBDIVISION , ON 108.12 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007). Area 108.12 acres Zoning Rural Development-5 (RD-5) Water Nolensville/College Grove Utility District Development Options Non-Traditional Wastewater Treatment and Disposal System Chapter 1101 Status Rural Map and Parcel 137---00400 File Number (5-2026-007) At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Item 17—Page 1 of 1 Reviewer: OCW Date: 8/13/2026 ITEM 17 SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG WRITER’S CABINS , ON 2.5 ACRES LOCATED OFF CLUB VIEW DRIVE IN THE 5TH VOTING DISTRICT (5-2026-006). Area 2.5 Zoning Rural Preservation – 1 (RP-1) Water Milcrofton Utility District Sewer Nontraditional Wastewater Treatment and Disposal System Development Options PRCD Chapter 1101 Status Rural File Number (5-2026-006) At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Item 18—Page 1 of 1 Reviewer: JYJ Date: 8/13/2026 ITEM 18 CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON 108.16 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (1 - 2026-203). Area 108.16 acres Lots 21 Zoning Rural Development-5 (RD-5) Water Nolensville/College Grove Utility District Sewer Non-Traditional Wastewater Treatment and Disposal System Development Options Major Conservation Subdivision Chapter 1101 Status Rural Map and Parcel 137---00400 File Number (1-2026-203) At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Item 19—Page 1 of 1 Reviewer: AVH Date: 8/13/2026 ITEM 19 CONCEPT PLAN REVIEW FOR 1600 RIVER LANDING D RIVE SUBDIVISION, CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING DRIVE IN THE 9TH VOTING DISTRICT (1-2026-204). Area 22.76 acres Lots Two (2) Zoning Rural Preservation-5 (RP-5) Water City of Franklin Sewer Berry’s Chapel Utility, Inc. Development Options Major Traditional Subdivision Chapter 1101 Status Rural Map and Parcel 038---01302 File Number (1-2026-204) At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Item 20—Page 1 of 3 Reviewer: JYJ Date: 8/13/2026 ITEM 20 PRELIMINARY PLAT REVIEW FOR THE VILLAGES AT TRIUNE W EST SUBDIVISION (REVISED), CONTAINING 98 SINGLE FAMILY LOTS, 214 TOWNHOME LOTS, AND T EN (10) NON-RESIDENTIAL LOTS ON 157.79 ACRES LOCATED OFF HORTON HIGHWAY IN THE 5TH VOTING DISTRICT (1 -2026- 309). Attachments 20-1 Preliminary Plat 20-2 Aerial Photograph 20-3 Applicant’s Request for Revised Concept Plan Conditions 20-4 Revised Review Memo from County’s Traffic Consultant 20-5 Original Review Memo from County’s Traffic Consultant Area 157.79 acres Zoning Triune Character Area -2 (TCA-2) Triune Character Area -3 (TCA-3) Triune Character Area -4 (TCA-4) Lots 98 Single-Family Lots 214 Townhome Lots Ten (10) Non-Residential Lots Water Nolensville/College Grove Utility District Sewer Triune Sewer Facility Development Options Conservation Subdivision, Multi-Family and Non-Residential Chapter 1101 Status Triune Planned Growth Area (TPGA) Map and Parcel 113--- 069.00 and 070.00 114--- 018.00, 020.00, 021.00, 022.00 and 022.01 File Number (1-2026-309) A Revised Concept Plan for this developme nt was approved at the June 2026 meeting, which added ten (10) non -residential lot s to the overall development. The currently approved Preliminary Plat depicts only the residential component of the development. The applicant is now requesting approval of a revised Preliminary Plat in order to incorporate both the residential and non-residential components of the development into a single Preliminary Plat. The revised Preliminary Plat is consistent with that depicted on the revised Concept Plan. During Concept Plan review, a Traffic Impact Analysis was perform ed by the applicant and reviewed by the County’s Traffic Consultant. Numerous roadway improvements were required in association with the development, and the construction of these improvements is currently underway. Item 20—Page 2 of 3 Reviewer: JYJ Date: 8/13/2026 As a condition of approval , the applic ant is required to install a traffic signal at the intersection of Horton Highway and Malachi Lane before the submittal of the Final Plat containing the 25 th lot. At this time, the applicant is requesting modification of this condition to allow the submittal of a Final Plat containing up to the 54th lot in Triune West (this Item) and up to the 30th lot in Triune East, which appears as Item 21 on this agenda, for a total of up to eighty-four ( 84) lots. The applicant has submitted a memo documenting this request (See Attachment 20 -3), and this memo has been reviewed by the County’s Traffic Consultant (See Attachment 20 -4). The County’s Traffic Consultant has noted allowing the applicant to submit Final Plats for the eight y-four (84) lots prior to construction of the signal at Horton Highway and Mal achi Lane will not result in a significant traffic impact to the surrounding roadway network. Therefore, the County’s Traffic Consultant has recommended the modification of the condition to allow the submission of a Final Plat containing up to the 54th lot in Triune West, and that the residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Mal achi L ane has been installed and is operational. Staff recommends approval of the revised Preliminary Plat with the following conditions, which shall be addressed in conjunction with Final Plat consideration: 1. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 55th lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4 and 20-5) shall be completed to the satisfaction of the Tennessee Department of Transportation; 2. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 55th lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachmen ts 20-4 and 20 -5) shall be completed to the satisfaction of the Williamson County Highway Superintendent; 3. As specified by the County’s Traffic Consultant, the i nstallation of traffic signals and construction of the right turn deceleration lanes on Horton Highway at the I- 840 Eastbound and Westbound Ramps shall be completed/constructed prior to the issuance of building permits for any of the non -residential land uses; 4. The residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane has been installed and is operational; 5. Prior to the submittal of the first Final Plat , the required Zoning Certificate for the wastewater treatment and disposal system shall be submitted , a nd all conditions associated with the wastewater site plan approval must be satisfied ; Item 20—Page 3 of 3 Reviewer: JYJ Date: 8/13/2026 6. Prior to consideration of Final Plat approval, the applicant shall submit HOA documents for review and approval by the County Attorney’s office. The HOA documents must address the greenway easement, the maintenance and operation of t he private roads and gate that meet the standards , and requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents must be submitted with the Final Plat, and the approved HO A documents must be recorded concurrently with the recording of the Final Plat; 7. A permit for the security gate will need to be obtained prior to its installation, and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance must be met; 8. Prior to the submittal of any Final Plat in which a greenway is located, the 12 - foot-wide paved multi-modal greenway trail should be constructed; 9. Establishment of a performance bond for roads, drainage and erosion control; 10. Establishment of a perfo rmance bond for water improvements in favor of Nolensville/College Grove Utility District; 11. Establishment of a performance bond for the wastewater collection system; 12. Submission of landscaping plans and establishment of a performance bond for landscaping improvements; 13. Execution of Performance Agreements for the above -referenced sureties; 14. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and 15. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. 86 88 87 8990919293949596 97 1 2 3 4 5 6 7 8 9 10 11 12 13 59 60 58 57 56 55 54 15 14 18 16 17 19 20 25 24 23 21 22 2726 30 28 29 3433 31 32 37 35 36 38 39 40 41 51 50 49 48 47 46 45 44 43 42 61 63 62 64 65 66 67 68 69 70 71 72 73 85 83 84 82 81 80 79 78 77 76 75 74 52 53 86 88 87 8990919293949596 97 1 2 3 4 5 6 7 8 9 10 11 12 13 59 60 58 57 56 55 54 15 14 18 16 17 19 20 25 24 23 21 22 2726 30 28 29 3433 31 32 37 35 36 38 39 40 41 51 50 49 48 47 46 45 44 43 42 61 63 62 64 65 66 67 68 69 70 71 72 73 85 83 84 82 81 80 79 78 77 76 75 74 52 53 HENRY HORTON HIGHWAY OS 121 120 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 108 109 110 111 112 113 114 115 116 117 118 119 99 100 101 102 103 104 105 106 224 225 226 227 228 229 223 222 221 220 219 218 154 153 155 156 157 152 151 150 149 158 159 160 107 0+00 0+00 0+37 0+64 0+61 0+64 POND C (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) (PRIVATE ALLEY) TCA3 TCA2 TCA3TCA4 TCA2TCA4 TCA2TCA4 OS OS OS OS 75-FT WATERWAY NATURAL AREA (WNA) WETLAND WITH 30-FT WATER NATURAL AREA (WTL-3) WETLAND WITH 50-FT WATER NATURAL AREA (WTL-4) WETLAND WITH 50-FT WATER NATURAL AREA (WTL-5) WET WEATHER CONVEYANCE (WWC-1/EPH-1) WILSON BRANCH PERENNIAL STREAM WITH 75-FT WATER NATURAL AREA (STR-1) 50-FT WATERWAY NATURAL AREA (WNA) INTERMITTENT STREAM WITH 50-FT WATER NATURAL AREA (STR-2) WET WEATHER CONVEYANCE WET WEATHER CONVEYANCE WITH DRAINAGE AREA GREATER THAN 5 ACRES (WWC-4) 25 FT DRAINAGE EASEMENT WET WEATHER CONVEYANCE WITH DRAINAGE AREA GREATER THAN 5 ACRES (WWC-5) 25 FT DRAINAGE EASEMENT WET WEATHER CONVEYANCE WITH DRAINAGE AREA GREATER THAN 5 ACRES (WWC-3) 25 FT DRAINAGE EASEMENT WETLAND WITH 50-FT WATER NATURAL AREA (WTL-6) 75-FT WATERWAY NATURAL AREA (WNA) WET WEATHER CONVEYANCE WET WEATHER CONVEYANCE WITH DRAINAGE AREA LESS THAN 5 ACRES (WWC-2/UDF-1) 25 FT DRAINAGE EASEMENT WET WEATHER CONVEYANCE WET WEATHER CONVEYANCE WITH DRAINAGE AREA GREATER THAN 5 ACRES (WWC-3) 25 FT DRAINAGE EASEMENT POND A POND B 178 181180179178177 206 207 208 209 210 204 203 202 201 192 193194195 191190189188187 200 199 198 197 196 186 185 184 183 182 175174173172 169 211 212 213 214 215 216 217 176 171 168167166165164163162 231232 233234 237 238 239240 241 230 251 250 249 248 247 246 258 257 256 255 254 253 252 266 265 264 263 262 261 285 283 282 281 280 279 278 277 276 275 274 273 272 271 270 293 292 291 290 289 288 287 286 298 297 296 295 294 301302 303 308 310311 312 307 306 305 260 259 235 309 304 269 268267 243244245 242 18'X28'USE /MAINTENANCE EASEMENT TYPICAL 18'X28'USE /MAINTENANCE EASEMENT TYPICAL 284 18'X28'USE /MAINTENANCE EASEMENT TYPICAL 18'X28' USE /MAINTENANCEEASEMENT TYPICAL 18'X28' USE /MAINTENANCEEASEMENT TYPICAL 18'X28' USE /MAINTENANCE EASEMENT TYPICAL 18'X28' USE /MAINTENANCE EASEMENT TYPICAL 18'X28' USE /MAINTENANCEEASEMENT TYPICAL 18'X28' USE /MAINTENANCEEASEMENT TYPICAL 236 40' ROW ROAD (PRIVATE DRIVE) 40' ROW ROAD (PRIVATE DRIVE) PRIVATE ALLEYPRIVATE ALLEY 75 FT 98 98 161 170 205 PRIVATE ALLEY 300299 40' ROW ROAD (PRIVATE DRIVE) 40' ROW ROAD (PRIVATE DRIVE) 40' ROW ROAD (PRIVATE DRIVE) PRIVATE ALLEY PRIVATE ALLEYPRIVATE ALLEY PRIVATE ALLEY PRIVATE ALLEY POND F 50 FT 15' LDSB 50' OS BUFFER LOT 321LOT 321 OS-6 LOT 316 OS-9 LOT 313 LOT 314 OS-8 OS-7 LOT 320 LOT 318 LOT 319 OS-5 LOT 315 LOT 317 OS-4 50' OSB 15' LDSB 15' LDSB 15' LDSB 15' LDSB 15' LDSB LOT 322 50' OSB 50' OSB 50' OSB 15' LDSB 15' LDSB 15' LDSB 50' OSB 50' OSB 15' LDSB 15' LDSB 50' OSB 50' OSB 50' OSB OS-4 SCALE: 1"=200' SURVEY DIVISION 214 Centerview Drive Suite 300 Brentwood, TN 37027 615.370.8500 615.370.8530 woldae.com Contact John Powell Ashby Communities, LLC. P.O. Box 190 Arrington, TN 37014 (615) 496-8681 SITE ADDRESS: 8039 HORTON HWY Arrington, TN 37014 RESOURCE PROTECTION NOTE: THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 AND ARTICLE 19: FLOOD HAZARD REDUCTION AND COMPLIANCE WITH THE NATIONAL FLOOD INSURANCE PROGRAM OF THE ZONING ORDINANCE FOR RESOURCE PROTECTION. THE RESOURCES INCLUDE, BUT ARE NOT LIMITED TO: STEEP SLOPE PROTECTION, WOODLAND AND TREE PROTECTION, WETLAND PROTECTION & MITIGATION, AND WATERWAY PROTECTION. THE RESOURCES NOT FOUND ON THE SITE ARE: KARST TOPOGRAPHY AND HISTORIC & CULTURAL RESOURCES CRITIAL LOT NOTE: * PROPOSED SINGLE FAMILY LOTS THAT HAVE EXISTING CRITICAL SLOPES ARE INDICATED WITH THIS SYMBOL (*). AN ENGINEERED SITE PLAN SHALL BE SUBMITTED AND APPROVED BY WILLIAMSON COUNTY ENGINEERING DEPARTMENT. ALL LOTS CURRENTLY CONTAIN CRITICAL SLOPES WITH EXISTING TOPOGRAPHY. ALL VERY STEEP SLOPES ARE CONTAINED WITHIN OPEN SPACE AREAS. 06 91 .SSE ET NN NEE O ATTACHMENT 20-1 ATTACHMENT 20-2 July 20, 2026 Mr. Aaron Holmes, AICP - Planning Director Williamson County Planning Commission 1320 West Main Street Suite 400 Franklin, TN 37064 Re: Villages at Triune West & East – Request for Revised Concept Plan Conditions Williamson County, Tennessee Dear Mr. Holmes, We respectfully request that Williamson County allow for the submittal and approval of a phased final plat for the residential lots within the development to be served exclusively by the approved site driveway connections to Murfreesboro Road (S.R. 96) for both the Villages at Triune West and Villages at Triune East developments. This request is based on the Traffic Impact Study (TIS) prepared by Civil & Environmental Consultants, Inc. (CEC), revised February 2025, and is supported by updated intersection capacity analysis (CEC, July 2026) demonstrating that the proposed plats operate within the traffic volumes and levels of service those intersections were designed and analyzed to accommodate. The current conditions of approval associated with the development require that all of the offsite roadway improvements be installed and approved by TDOT prior to being able to submit for a Final Plat for more than 24 residential units from either the Villages at Triune West or East subdivisions. This is based on the assumption that the existing intersection of Horton Highway and Malachi Lane restricts what traffic can be discharged at that intersection under current unsignalized conditions. The developer is preparing to submit the first final plats for both the West and East sides in time to appear on the October 2026 Planning Commission meeting agenda. The proposed first final plats are as follows: • Villages at Triune West — First Final Plat: 54 residential units (mix of single-family and townhomes), to be submitted in advance of the October 2026 Planning Commission meeting. • Villages at Triune East — First Final Plat: 30 residential units (mix of single-family and townhomes), submitted on the same schedule for the October 2026 Planning Commission meeting. The timing of this request is driven by the construction schedule of the signalized intersection at Horton Highway and Malachi Lane, which is not anticipated to be complete and open to traffic until December 2026 — after the targeted October Planning Commission approval of these first final plats. As detailed in the following sections, the traffic analysis in this letter accounts for that interim condition and confirms that the S.R. 96 intersections can accommodate the proposed plats within the volumes already studied and approved. Additionally, if allowed and approved by the Planning Commission at the October 2026 meeting, the recording of the Final Plat and then construction of the homes within the plat can begin. It is anticipated that the homes from the first plat would not be fully constructed until well into 2027, with the traffic signal fully installed and operating. CURRENT CONDITIONS OF APPROVAL — RESIDENTIAL The Triune development received approval for the following residential program, as analyzed at full build-out in the CEC TIS: ATTACHMENT 20-3 Table 1 — Approved Residential Program Development Area Single-Family Townhomes Total Units Triune West 99 213 312 Triune East 58 64 122 Total 157 277 434 With respect to platting and access, the existing condition of approval limits residential development to a combined total of 24 residential lots across both the East and West sides prior to installation of the signalized intersection at Horton Highway (U.S. 31A/41A/S.R. 11) and Malachi Lane (the “Malachi Lane Signal”). This interim limit reflects the TIS assumption that the Malachi Lane Signal would be operational to serve as the principal access for Triune East and a significant secondary access for Triune West at the time residential occupancy commenced. BASIS FOR THIS REQUEST — INTERIM ACCESS DURING CONSTRUCTION The approved development includes a second primary access connection via the Malachi Lane Signal, which the TIS analyzed as the principal point of access for the Triune East site and a significant secondary access for Triune West. Construction of that signalized intersection is about to begin; however, it is not anticipated to be open to traffic until December 2026. During the interim period prior to the Malachi Lane Signal opening, the S.R. 96 site driveways will serve as the sole access connection for residential traffic on both the West and East sides of the development. Under this scenario, 100% of the vehicle trips generated by the platted residential units will be routed through the S.R. 96 intersections. The 24-lot interim limit would unduly constrain the initial development phase during the intervening period despite the availability of adequate capacity at the S.R. 96 site driveways, which were designed and analyzed to accommodate substantially higher volumes at full build-out. As demonstrated by the updated capacity analysis below, the requested 54 (West) and 30 (East) units can be accommodated at the S.R. 96 driveways during the interim period at acceptable levels of service. Once the Malachi Lane Signal is open, residential trips will distribute across all approved access points per the TIS distribution percentages, materially reducing the S.R. 96 share and permitting the platting of any remaining residential units without further constraint. TRIP GENERATION — REQUESTED UNITS Trip generation for the requested first final plats was prepared by CEC using ITE Trip Generation, 12th Edition (average rates), for Land Use Code 210 (Single-Family Detached Housing) and Land Use Code 215 (Single-Family Attached Housing / Townhomes). The results, which serve as the basis for the interim capacity analysis, are summarized below. Table 2 — Triune West First Final Plat (54 Units): Trip Generation Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total) Single-Family (210) 15 148 3 / 2 / 17 9 / 5 / 14 Townhome (215) 39 276 5 / 13 / 18 11 / 9 / 20 West Total 54 424 8 / 21 / 29 20 / 14 / 34 Table 3 — Triune East First Final Plat (30 Units): Trip Generation Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total) Single-Family (210) 8 89 2 / 4 / 6 5 / 2 / 7 Townhome (215) 22 155 3 / 7 / 10 6 / 5 / 11 East Total 30 244 5 / 11 / 16 11 / 7 / 18 No internal capture or pass-by reductions were applied to the residential trip generation, consistent with the TIS treatment of the residential land uses. During the interim phase, 100% of these trips are assigned to the respective S.R. 96 site driveways, as reflected in the CEC analysis. INTERIM TRIP DISTRIBUTION During the interim phase, because no access is provided at Malachi Lane, 100% of the trips generated by the requested residential units are assigned to the respective S.R. 96 site driveways. These trips will follow the trip distribution from the original TIS and a figure has been provided in the attachments showing the percentage of trips assigned. The Triune West driveway lies approximately 1,600 feet west of the Horton Highway / S.R. 96 intersection, and the Triune East driveway approximately 2,300 feet east of it. The intersection therefore lies between the two driveways. Only West site trips traveling east, and East site trips traveling west, traverse the Horton Highway / S.R. 96 intersection — approximately 21 A.M. and 25 P.M. peak-hour site trips, or roughly 1% of the existing intersection volume. This distribution is reflected in the 2026 Build turning-movement volumes used in the capacity analysis below. INTERIM CAPACITY ANALYSIS — 2026 BUILD CONDITIONS At the County's request, CEC performed a peak-hour capacity analysis of the three study intersections that serve or are traversed by interim site traffic, using the Highway Capacity Manual, 7th Edition methodology in Synchro Version 12, consistent with the TIS. The interim (2026 Build) volumes were developed by adding the site trip generation above — assigned 100% via the S.R. 96 driveways per the interim access condition — to the 2026 No-Build turning-movement volumes from the TIS. The analysis reflects the committed turn-lane improvements at each S.R. 96 driveway that are currently under construction and will be finished by the time the first final plat will be submitted. Results for the weekday A.M. and P.M. peak hours are presented below. S.R. 96 Site Driveways (Unsignalized, Two-Way Stop Control) Both S.R. 96 site driveways operate at an overall intersection delay of less than one second per vehicle (LOS A) in both peak hours. The stop-controlled northbound site-exit approaches operate at acceptable levels of service with negligible queuing (95th-percentile queues of less than one vehicle). The Murfreesboro Road left-turn movements entering the driveways operate at LOS A–B. Table 4 — 2026 Build LOS & Delay: S.R. 96 Site Driveways Intersection / Movement AM LOS (Delay) AM 95% Q PM LOS (Delay) PM 95% Q West Dwy — WB Left (into dwy) A (8.1) 0 B (10.8) 0.1 West Dwy — NB Left (exit) E (36.0) 0.1 E (35.2) 0.1 West Dwy — NB Right (exit) B (10.5) 0.1 C (19.2) 0.1 West Dwy — NB approach C (15.4) — C (22.7) — Intersection / Movement AM LOS (Delay) AM 95% Q PM LOS (Delay) PM 95% Q West Dwy — Overall A (0.3) — A (0.3) — East Dwy — WB Left (into dwy) A (7.5) 0 A (8.8) 0 East Dwy — NB approach (exit) B (14.6) 0.1 C (16.4) 0.1 East Dwy — Overall A (0.2) — A (0.2) — The northbound left-turn movement at the West driveway reflects LOS E; this is typical of a low-volume minor-street left turn crossing a higher-volume arterial under stop control and involves only a handful of vehicles per hour (a 95th-percentile queue of less than one vehicle). It does not affect the overall driveway operation, which remains LOS A. Horton Highway / S.R. 96 (Signalized) The Horton Highway / S.R. 96 signalized intersection was analyzed under both the 2026 No-Build and 2026 Build (with 84 interim units) conditions. The results demonstrate that the interim plats do not degrade the overall operation of this intersection relative to the No-Build condition. In the A.M. peak hour, the overall intersection delay under the Build condition is essentially unchanged from — in fact marginally better than — the No-Build condition. In the P.M. peak hour, the overall level of service remains within one grade of the No-Build condition. Table 5 — Horton Hwy / S.R. 96: 2026 No-Build vs. 2026 Build (84 Units) Approach AM No-Build AM Build PM No-Build PM Build Murfreesboro Rd — Eastbound D (37.0) C (30.5) C (30.9) D (39.6) Murfreesboro Rd — Westbound F (92.5) F (93.9) C (28.3) C (26.3) Horton Hwy — Northbound E (65.7) E (56.9) C (27.1) C (30.0) Nolensville Rd — Southbound F (111.2) F (117.9) D (37.1) D (48.8) Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8) The westbound and southbound approaches reflect LOS F in the A.M. peak hour under both the No-Build and Build conditions. This is a pre-existing regional congestion condition at this intersection that is present with or without the interim plats; the addition of the 84 interim units does not change the overall A.M. level of service (LOS E in both cases) and in fact slightly reduces overall delay. As documented in the TIS, improvements at this intersection are tied to regional conditions and the broader Horton Highway corridor rather than to this residential phase. DISCUSSION OF INTERIM IMPACTS The updated CEC capacity analysis confirms that the requested interim plats can be accommodated during the period prior to installation of the Malachi Lane Signal without adverse operational impact at the study intersections: • S.R. 96 site driveways: Both driveways operate at overall LOS A in both peak hours, with 95th- percentile queues of less than one vehicle on the stop-controlled site-exit approaches. The committed turn-lane improvements accommodate entering and exiting movements without impeding S.R. 96 through-traffic. The interim volumes (29 West / 16 East in the A.M.; 34 West / 18 East in the P.M.) represent less than 3% of the existing S.R. 96 mainline traffic at each location. • Horton Highway / S.R. 96 signalized intersection: Only approximately 21 A.M. and 25 P.M. site trips traverse this intersection — roughly 1% of its total entering volume. The analysis confirms the interim plats do not degrade the overall level of service: the A.M. peak remains LOS E (with slightly lower overall delay than No-Build), and the P.M. peak remains within one grade of No- Build. The LOS F approaches present in the A.M. peak are pre-existing regional conditions independent of this residential phase. • Relationship to the analyzed full build-out: The TIS analyzed each of these intersections under the full build-out condition — the entire 434-unit residential program plus all commercial land uses — and identified the improvements necessary to maintain acceptable operations. The interim phase places only a small fraction of that analyzed volume on the network, entirely via the S.R. 96 driveways, and therefore operates well within the previously accepted envelope. CONCLUSION This letter documents the current residential conditions of approval, the specific interim plat modification requested (54 units West / 30 units East, all single-family and townhome product), the interim access configuration in which all site access is provided exclusively via the S.R. 96 driveways with no Malachi Lane access until the signal is complete, the trip generation for the requested units, and the updated CEC capacity analysis of the three study intersections. That analysis confirms that the S.R. 96 site driveways operate at overall LOS A, and that the Horton Highway / S.R. 96 signalized intersection is not degraded by the interim plats relative to the 2026 No-Build condition. All required roadway improvements at each S.R. 96 driveway are committed conditions of development approval. Upon completion and opening of the Malachi Lane / Horton Highway signalized intersection — anticipated December 2026 — residential trips will distribute across all approved access points consistent with the TIS, and the developer will plat all remaining units in accordance with the full build distribution model. We respectfully request that the Planning Commission revise the approved conditions to allow for the phased final plat approach described herein and are available to meet or provide any additional information at your convenience. Sincerely, Will Crunk, PE Crunk Engineering LLC 1 | P a g e MEMORANDUM To: Aaron Holmes, Williamson County Planning Department From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC Date: 8/5/26 Subject: Triune Mixed-Use – Requested Conditions of Approval Revisions Introduction The Triune Mixed -Use development includes a combination of residential and commercial components located at the intersection of Horton Highway (US 41/SR 11) and Murfreesboro Road (SR 96) in unincorporated Williamson County. Following submittal and review of a Traffic Impact Study (TIS) according to the County’s guidelines, the development was approved with conditions, and construction of the first development phase, which includes all residential components split on the east and west sides of Horton Highway, began in 2026. The conditions of approval placed on the development included multiple requirements specific to off-site transportation improvements and their timing relative to preliminary and final plat submittals. As residential lots continue to be submitted for preliminary and final plats, the off-site improvements recommended in the February 2025 TIS are being constructed as required. One specific condition of approval included construction of a traffic signal at the intersection of Horton Highway and Malachi Lane, which will serve as a primary access to both Triune East and West at full buildout. This signal was required to be constructed and operational before the 25 th residential lot was submitted for final plat based on the existing and projected traffic volumes at this intersection. According to the developer’s engineer, Crunk Engineering, construction of this signal has been delayed but is still on track to be completed by the end of 2026 , which the development team claims will be well in advance of any residential units being completed . Therefore, the applicant is requesting a change to the existing conditions of approval in order to adhere to their desired development timeline. More specifically, the applicant is requesting that they be allowed to submit final plats for 84 residential units (60 more than is currently allowed) prior to the traffic signal being constructed. The applicant has submitted a memo documenting this request, including supplemental traffic operational analysis to evaluate the potential interim condition in which 84 lots are constructed but access to Malachi Lane is not provided, routing all development-generated traffic through the two site accesses on Murfreesboro Road and the intersection of Horton Highway and Murfreesboro Road. ATTACHMENT 20-4 2 | P a g e Analysis Review In order to evaluate the proposed interim access condition, a small-scale traffic impact analysis was conducted with standard components – trip generation, trip distribution and assignment, and capacity analysis – all described below. • Trip Generation - The projected trip generation was calculated for both Triune East, which includes a proposed 15 single family homes and 39 townhomes, and Triune West, which includes a proposed 8 single family homes and 22 townhomes, for a combined 84 residential dwelling units. The trip generation calculations do not follow the latest version of ITE’s Trip Generation Manual, 12th Edition, as stipulated in the memo, nor do they use industry standard practice of using the fitted curve equations as appropriate; however, with the relatively low number of dwelling units proposed, the discrepancy in trips generated is unlikely to make a difference in the operational outcomes. • Trip Distribution and Assignment – Under the interim access condition, all trips generated by the additional 84 residential units would utilize the Triune East and Triune West accesses on Murfreesboro Road. According to the 2025 TIS, trips generated by the development were expected to be oriented as follows: o 25% of trips to/from I-840 WB ramps o 20% of trips to/from I-840 EB ramps o 20% of trips to/from the west on Murfreesboro Road o 15% of trips to/from the east on Murfreesboro Road o 10% of trips to/from south on Horton Highway o 10% of trips to/from north on Horton Highway/Nolensville Pike With access limited to Murfreesboro Road, trips would redistribute at the two accesses and at the signalized intersection of Horton Highway and Murfreesboro Road. The following turning movements would see higher volumes during peak periods: o Eastbound right turns on Murfreesboro Road at the Triune East access o Westbound left turns on Murfreesboro Road at the Triune West access o Northbound left and right turns on Horton Highway at the existing signal o Eastbound right and westbound left turns on Murfreesboro Road at the existing signal It should be noted that the northbound and southbound through volumes on Horton Highway at the existing Malachi Lane intersection will also increase with the redistribution of traffic volumes generated by the 84 residential units . While not included in the requested analysis, it can be anticipated that any additional through volume on the major street will increase delays for the minor street volumes that exist today. 3 | P a g e • Capacity Analysis – Capacity analysis was completed for both projected 2026 AM and PM peak hours under the interim access scenario. The analyses account for the conditioned off-site improvements at both Murfreesboro Road accesses as they will be complete prior to construction of any residential units. The volumes, traffic control, and intersection geometry utilized in the projected analyses are reasonably correct. Table 1 summarizes the level of service (LOS) and vehicular delay projected at the three study intersections under the 2026 background, or no-build, condition as well as the 2026 projected, or build, condition during which access to Malachi Lane is not provided and all residential trips for the proposed 84 residential units is routed through the Murfreesboro Road accesses. The capacity analysis addressed the AM and PM peak hours at three intersections: the existing signalized intersection of Horton Highway and Murfreesboro Road, and the two unsignalized Murfreesboro Road driveways serving Triune East and Triune West. The no- build condition reflects the intersection geometry, traffic control, and signal timing documented in the February 2025 TIS, and the build condition adds the redistributed trips from the interim access scenario described above. The two driveway intersection s are shown only under the build condition, since they do not exist without the development. One item in the capacity analysis should be noted. The signal timing at Horton Highway and Murfreesboro Road was not held constant between the no-build and build scenarios; the cycle length was shortened along with the retiming. In the AM peak hour, the overall cycle length dropped from approximately 190 seconds under no-build to approximately 150 seconds under build, and in the PM peak hour it dropped from approximately 103 seconds to approximately 88 seconds, even though the traffic volumes at this intersection are nearly identical between the two scena rios. Because the timing plan changed at the same time as the volumes, the delay and LOS differences reported for this intersection reflect the combined effect of both variables, and the operational impact of the additional 84 units cannot be isolated from the effect of the signal retiming. The shorter cycle s improve LOS for movements with excess capacity but push already -saturated movements, including the WB and SB through movements, further past capacity, worsening their delay and queuing. The net effect is a slight improvement in the AM peak, where the intersection was already failing, but a full LOS drop from C to D in the PM peak, where it previously was not. Setting aside the signal timing discrepancy at Horton Highway and Murfreesboro Road, the additional volumes generated by the interim access scenario are expected to have a limited effect on operations at the three study intersections. The two new driveways operate at LOS C or better for nearly all movements, with the exception of the northbound left turn at the Triune West driveway, which operates at LOS E in both peak hours and is expected for an unsignalized minor street approach movement along an 4 | P a g e arterial. The existing signalized intersection already operates at LOS E in the AM peak hour and LOS C to D in the PM peak hour under the no -build condition, and the incremental delay attributable to the added 84 units, apart from the timing changes discussed above, is small relative to the background condition. Only one movement, the northbound left turn, deteriorates in LOS between the no-build and build conditions during the PM peak hour. Given that this condition is temporary and will be resolved once the Malachi Lane signal is constructed, these results do not support a requirement for additional off -site infrastructure improvements to accommodate the interim access scenario. Table 1. Comparison of 2026 Background (No-Build) and Projected (Build) Peak Hour Operations Intersection/Movement LOS (Vehicular Delay in sec/veh) AM No-Build AM Build PM No-Build PM Build Murfreesboro Road and Horton Highway/ Nolensville Pike EB Left Turn E (76.0) E (58.0) C (23.3) C (21.5) EB Through D (45.2) D (37.9) D (36.6) D (52.5) EB Right Turn C (21.8) B (19.4) C (26.7) C (30.4) WB Left Turn D (42.6) C (34.5) C (27.9) C (26.0) WB Through F (98.6) F (101.9) C (28.4) C (26.5) WB Right Turn NB Left Turn F (100.9) F (87.2) C (27.5) D (37.0) NB Through C (31.7) C (27.6) C (26.9) C (25.9) NB Right Turn SB Left Turn D (46.3) D (38.1) C (23.7) C (21.2) SB Through F (113.7) F (120.9) D (38.9) D (52.5) SB Right Turn Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8) Murfreesboro Road and Triune East Driveway WB Left Turn -- A (7.5) -- A (8.8) NB Left Turn -- B (14.6) -- C (16.4) Murfreesboro Road and Triune West Driveway NB Left Turn -- E (36.0) -- E (35.2) NB Right Turn -- B (10.5) -- C (19.2) WB Left Turn -- A (8.1) -- B (10.8) 5 | P a g e Conclusion Based on the review of the supplemental traffic operational analysis, allowing the applicant to submit final plats for up to 30 lots in Triune East and up to 54 lots in Triune West for a total of 84 residential units prior to construction of the Malachi Lane signal1 is not expected to result in a significant traffic impact to the surrounding roadway network. The interim access scenario, which routes all development-generated trips through the two Murfreesboro Road driveways and the existing signalized intersection at Horton Highway, results in relatively minor incremental delays at the existing signal beyond what is already occurring under background conditions. This condition is temporary by design and will be resolved once access from Triune East and West is provided via Malachi Lane. Therefore, the request to submit final plats for the 84 lots, up to 30 lots in Triune East and up to 54 lots in Triune West, is reasonable provided that the residential lots within Triune East and Triune West are not permitted to access Malachi Lane or the traffic signal is constructed, which the applicant's engineer indicates remains on track for completion by the end of 2026, well ahead of any residential units being constructed. Accordingly, I do not recommend requiring additional off-site infrastructure improvements as a condition of approving the applicant's request, and I recommend that residential lots in either Triune East or Triune West shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane is installed and operational in order to protect the County and existing traffic on Malachi Lane from added development traffic in the interim. Should you have any questions or need additional information, please contact me. Sincerely, Kayla Ferguson, PE, AICP Burch Transportation, LLC 1 The existing condition of approval limits residential development to a combined total of 24 residential lots across both Triune East and West prior to installation of the signal . 1 | Page MEMORANDUM To: Aaron Holmes, Williamson County Planning Department From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC Date: 3/3/2025 Subject: Triune Mixed-Use TIS Review Thi s memorandum provides the findings of the independent review of the Triune Mixed -Use TIS submitted to Williamson County Planning on 2/20/2025 for a concept plan submittal. The review focused on the following three items: consistency with assumptions discussed in the traffic study scoping and included in the executed MOUA, review of the traffic operational analyses, and evaluation of recommended infrastructure improvements. Based on this review, we identify any necessary modifications to the traffic study and/or the recommendations that ensure consistency with the County’s Traffic Study Guidelines and mitigate impacts of the proposed project. G eneral Project Information and Traffic Study Scope The Triune Mixed-Use development proposal includes a new development plan located on either side of Horton Highway (US 41A/SR 11) between Murfreesboro Road (SR 96) and I -840 in the Triune area of Williamson County. The proposed development plan is referred to as Triune East and Triune West based on its bifurcation via Horton Highwa y. The two sites will each include a mix of residential unit types and commercial space and have six total accesses proposed – two on Murfreesboro Road and four on Horton Highway. Based o n the proposed density and trip generation of the development, a Traffic Impact Study was required. A traffic study scoping call was conducted with the applicant’s traffic study preparer on August 21, 2024. The outcome of this meeting was an agreed upon set of assumptions and study parameters for the traffic study. Table 1 identifies key traffic study elements and an evaluation of their consistency with the agreed upon scope. As noted, the traffic study submitted accurately reflects the current concept plan and the scope as agreed upon in the MOUA. ATTACHMENT 20-5 2 | Page Table 1: Review of Traffic Study Scope Elements Project Characteristic Documented in Traffic Study Consistent with MOUA? Proposed Land Use and Density 342 single-family residential units 98 multifamily residential units 42,400 sf restaurant space 54,400 sf retail space 45,000 sf supermarket 16,000 sf hardware store 50,400 sf office space 318-room hotel Ye s No Trip Generation AM: 1,184 total / 612 enter / 572 exit PM: 1,777 total / 938 enter / 839 exit Yes No Notes: Exact trip totals are higher than presented in MOUA, but calculations are appropriate and correct. Buildout and Background Growth Buildout Horizon: 2026 / 2031 Annual Growth Rate: 1.0% Site Specific Growth: Burns Property, Troubadour, Kings Chapel, Hardeman Springs, Fiddler’s Glen, and Patterson Road Development Ye s No Study Area Segments: Murfreesboro Road; Horton Hwy Intersections: • Horton Highway / I-840 EB ramp • Horton Highway / I-840 WB ramp • Horton Highway / Murfreesboro Road • Horton Highway and Malachi Lane/Site Access • Horton Highway / Triune East Site Access • Horton Highway / Triune West Site Access • M alachi Lane / Site Access • M urfreesboro Road / Triune West Site Access • Murfreesboro Road / Triune East Site Access Ye s No Notes: Additional site accesses were included to reflect changes in the site plan following the MOUA execution. T raffic Operational Analyses The operational analyses for the intersections and roadway segments within the study area were based on methods from Highway Capacity Manual. The following bullets highlight a review of the analysis as documented in the TIA: • Data to support the traffic analyses was collected from 7:00-9:00 AM and 4:00-6:00 PM on Thursday, September 5, 2024 when local schools were in session. • Based on the data collected and capacity analysis, there are multiple critical turning movements that operate at LOS E or worse during existing peak hour conditions. More s pecifically, minor street left turn movements on the I-840 eastbound and westbound ramps as well as multiple movements at the signalized intersection of Murfreesboro 3 | Page Road and Horton Highway/Nolensville Road all currently operate unacceptably during at least one if not both peak hours. • Background and projected capacity analysis is divided into two horizon years. The first represents a 2026 buildout year, which is expected to include all of the proposed residential density in the Triune East and Triune West developments. The second represents a 2031 buildout year, which is expected to include all of the non-residential density. • Continued growth in the region as well as this specific area of the County add significant peak hour volumes to the critical intersections over the 7-year buildout horizon. This causes already-failing movements to further deteriorate with significant increases in average vehicular delays during peak hours before construction of the Triune mixed-use development. The most significant delay is predicted for vehicles turning left from the stop-controlled I-840 eastbound ramp onto Horton Highway, averaging ~5 minutes per vehicle in the AM peak hour and ~27 minutes per vehicle in the PM peak hour in 2031. • Addition of the proposed Triune Mixed-Use project causes significant increases in delays for aforementioned critical turning movements at existing intersections. Table 2 highlights the specific scenario in which critical turning movements are expected to operate at LOS E (indicated with green shading) and the corresponding vehicular delay expressed in seconds per vehicle. For the 2026 and 2031 projected scenarios, the additional delay added by the proposed project is shown in parentheses. • As shown in Table 2, the intersection of Horton Highway and Murfreesboro Road has multiple movements that already operate at LOS E, but the relative increase of delay caused by the Triune Mixed-Use development is low. For example, the proposed development is expected to add a maximum of 36 seconds to any of these movements, specifically the westbound through/right turn movement. It should be noted that TDOT has plans to eventually widen the Murfreesboro Road in the vicinity of the Triune Mixed-Use project. The widening of Murfreesboro Road will also include capacity improvements at this intersection that will help to alleviate the existing and projected delays. However, no funding is allocated for this project and the anticipated completion is, therefore, unknown. • By contrast, delays added to the unsignalized I-840 ramps with completion of the proposed project are significant. Traffic signal warrant analyses were conducted to determine if and when traffic volumes would justify the need for traffic signals at these locations. According to methodology set forth in the MUTCD and the typical requirement to satisfy an 8-hour volume warrant on State Routes like Horton Highway, both of these ramp intersections warrant traffic signal control under existing conditions. Further, the study notes that additional capacity will be needed along Horton Highway, specifically right turn lanes onto the I-840 ramps, in addition to traffic signal control to mitigate projected delays. 4 | Page Table 2: Summary of Critical Existing Intersection Operations Intersection Critical Movement Peak Hour Average Delay in Seconds/Vehicle (Development-Induced Increase) 2024 Existing 2026 Background 2031 Background 2026 Projected 2031 Projected Horton Highway and Murfreesboro Road NB Left Turn AM 77 sec 101 sec 114 sec 96 sec (-5) 132 sec (+18) PM SB Through/Right Turn AM 80 sec 114 sec 122 sec 124 sec (+10) 145 sec (+23) PM 56 sec (+17) 55 sec (+11) WB Through/Right Turn AM 77 sec 99 sec 118 sec 107 sec (+8) 154 sec (+36) PM EB Left Turn AM 76 sec 89 sec 66 sec (-10) 83 sec (-6) PM EB Through/Right Turn AM PM 60 sec (+23) 52 sec (+10) I-840 WB Ramps and Horton Highway WB Left Turn AM 65 sec 85 sec 373 sec (+308) 761 sec (+676) PM 38 sec 126 sec 171 sec 712 sec (+586) 1,193 sec (+1,022) WB Right Turn AM 38 sec 38 sec (+0) 161 sec (+123) PM I-840 EB Ramps and Horton Highway EB Left Turn AM 96 sec 215 sec 305 sec 489 sec (+274) 1,754 sec (+1,449) PM 552 sec 1,177 sec 1,613 sec 2,444 sec (+1,267) 6,655 sec (+5,042) 5 | Page • Based on the presented traffic volumes and the methodologies in NCHRP Report 457 – Evaluating Intersection Improvements: An Engineering Study Guide , turn lanes are warranted at the following site accesses during different build years (shown in parentheses) for the proposed development: o Northbound right turn lane on Horton Highway at southern Site Access (2026) o Southbound right turn lane on Horton Highway at southern Site Access (2031) o Northbound right turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Northbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Southbound right turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Southbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Eastbound right turn lane on Murfreesboro Road at West Site Access (2026) o Westbound left turn lane on Murfreesboro Road at West Site Access (2026) o Westbound left turn lane on Murfreesboro Road at East Site Access (2031) • Deceleration lengths for the recommended turn lanes are based on a 35-mph speed, which is 10 mph lower than the 45 -mph posted speed limit south of the site on Horton Highway and on Highway 96 . This is typical in constrained situations where vehicles are assumed to begin decelerating in the adjacent through lane. North of the project site, the posted speed limit is 35 mph on Horton Highway near the Highway 96 traffic signal. • Recommended storage lengths were sourced from the Highway Capacity Manual based on facility type and context as well as TDOT’s review of the preliminary design plans. The recommended storage lengths are expected to be sufficient to accommodate projected queues output from the capacity analysis. • Intersection sight distance was not evaluated in the TIS as requested in the scoping call by TDOT but were later provided with proposed site plans submitted to the County for review. These exhibits show the available sight distance at the proposed intersections of Highway 96 and the Triune East and Triune West accesses. Based on examination of those exhibits, sufficient intersection sight distance is available at these locations. Exhibits were not provided for the site accesses on Horton Highway; however, based on street view imagery, it is anticipated that intersection sight distance at these locations is sufficient. • Per TDOT’s request, SIDRA analysis was conducted for the intersection of Horton Highway and Malachi Lane/Site Access. The significant volume northbound and southbound on Horton Highway causes a single lane roundabout to operate at LOS F with significant queues under projected con ditions. A multilane roundabout that provides additional capacity for these movements would improve LOS and resolve queue issues; however, this was not recommended in the TIS based on potential property restrictions. 6 | Page Based on the review of traffic study, it appears that the operational analyses are based on reasonably correct peak hour volumes, intersection laneage, and traffic control. Recommended Infrastructure Improvements Based on the operational analysis as well as signal and turn lane warran ts, the following infrastructure improvements are recommended in the TI S. The timing of each improvement is denoted in parentheses. For each set of improvements, a response is noted below. 1. Murfreesboro Road with Triune East Site Driveway (Phase 1 – 2026 and Phase 2 – 2031) o Implement unsignalized intersection control (stop on minor street approach) o Construction of northbound Site Driveway shared left/right turn lane o Construction of westbound Murfreesboro Road left turn lane (595 feet total length including taper, deceleration and storage) Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for improvements at this intersection should be approved by TDOT and Williamson County prior to application of any building permits for Phase 2, which includes all non-residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before issuance of building permits for Phase 2. 2. Improvements at Horton Highway and Murfreesboro Road (Phase 1 – 2026 and Phase 2 – 2031) o Optimization of traffic signal timings including cycle lengths and splits Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. This should be completed following completion of both phases in 2026 and 2031. 3. Murfreesboro Road with Triune West Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (stop on minor street approach) o Construction of westbound Murfreesboro Road left turn lane (595 feet total length including taper, deceleration and storage) o Construction of eastbound Murfreesboro Road right turn lane (360 feet total length including taper, deceleration and storage) o Site Driveway northbound left turn lane (100 ft of storage plus taper) and northbound right turn lane Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for these turn lane improvements should be approved by TDOT and Williamson County prior to submittal of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Con struction of all 7 | Page recommended turn lanes should be completed before submittal of the final plat for Phase 1. 4. I mprovements at Horton Highway and Malachi Lane/Site Access (Phase 1 – 2026) o Implementation of signalized intersection control o Construction of Horton Highway northbound left turn lane (355 feet total length including taper, deceleration and storage) and northbound right turn lane that extends through the upstream proposed driveway. o Construction of Horton Highway southbound left turn lane (460 feet total length including taper, deceleration and storage) and southbound right turn lane ( 360 f eet total length including taper, deceleration and storage) o Construction of eastbound Site Driveway to include one left turn lane (100 ft o f s torage plus taper), one through lane, and one right turn lane (100 ft of storage plus taper) o Construction of westbound Malachi Lane left turn lane (200 ft of storage plus taper) and westbound through/right turn lane o Due to the proximity of Malachi Lane with the existing gas station and proposed Triune East/West Site Driveway s, northbound turn lanes will extend beyond those driveways. Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. With implementation of traffic signal control, left turn movements should all be protected-permitted phasing and should include right turn overlaps where applicable. D esign and construction plans for improvements at this intersection should be approved by TDOT and Williamson County prior to submittal of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before submittal of the final plat for lots 1 through 24 in Phase 1. The installation of traffic signal control should be completed before submittal of the final plat for the 25 th lot. 5. H orton Highway with Triune East/West Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (stop on minor street approach) o Right-in-right-out (RIRO) operation for both East and West site driveways o Construction of Horton Highway northbound right turn lane (255 feet total length including taper, deceleration and storage) and southbound right turn lane ( 230 feet total length including taper, deceleration and storage) Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for these turn lane improvements should be approved by TDOT and Williamson County prior to submittal 8 | Page of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before submittal of the final plat for Phase 1. 6. Horton Highway with I-840 EB and WB Ramps (Phase 1 – 2026) o The installation of traffic signal control should be implemented but should not be the sole responsibility of the developer for the Triune development. Instead, solutions with TDOT and Williamson County regarding funding of these regional improvements should be explored before full build -out of the Triune Development. However, construction of residential components for Phases 1-3 of Triune East and West should be permitted under existing traffic control with coordination with TDOT and Williamson County. Review Evaluation: As noted in the TIS analyses, the existing unsignalized intersections of Horton Highway and the I-840 EB and W B Ramps both operate unacceptably under existing peak hour conditions. The minor street stop - controlled ramp movements experience heavy delays due to the high northbound and southbound volumes on Horton Highway. Eight-hour volume warrants as outlined in the MUTCD warrant the installation of a traffic signal at these locations in 2024. The need for this signalization is further compounded with additional background development growth and the proposed Triune Mixed-Use development. Based on coordination with TDOT, the need for signalization and additional capacity at t hese ramps has already been identified through the RSAR safety process. However, funding has not been allocated for the design or construction in TDOT’s current 3 -Year Plan that extends through 2027. Therefore, the installation of traffic signals and right turn deceleration lanes on Horton Highway should be completed before building permits are issued for any non -residential land uses in Phase 2 of the Triune Mixed -Use development. In addition and as recommended in the TIS, the Triune Mixed -Use development should coordinate with TDOT and Williamson County to participate in the funding of these improvements. 7. Malachi Lane with Triune East Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (all-way stop) Review Evaluation: Based on the projected volumes at this intersection and historic crash data, all-way stop control is unlikely to be warranted. Therefore, it is recommended that this intersection be designed and constructed as a two-way stop intersection with stop-control implemented for the northbound approach of the Triune East access. 9 | Page All of the above infrastructure improvements should be constructed in tandem with the specific phase identified above. For additional clarity, the following figures highlight the specific improvements and their timing. 10 | Page Figure 1: Location of Recommended Off-Site Improvements per TIS Recommendations and 3rd Party Review 11 | Page Figure 2a: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review 12 | Page Figur e 2b: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review 13 | Page Conclusion – Study Acceptance The Triune Mixed-Use TIS submitted February 2025 includes all of the typically required traffic study components and identifies reasonable and beneficial infrastructure improvements to be made as a result of the proposed development . At this time, we recommend acceptance of the current traffic study and its recommendations . Timing of the various improvements associated with the various development phases should be incorporated into the conditions of approval as noted in the review comments. Should you have any questions or need additional information, please contact me. Sincerely, K ayla Ferguson, PE, AICP Burch Transportation, LLC Item 21—Page 1 of 3 Reviewer: JYJ Date: 8/13/2026 ITEM 2 1 P RELIMINARY PLAT REVIEW FOR THE VILLAGES AT TRIUNE E AST SUBDIVISION (REVISED), CONTAINING 59 SINGLE FAMILY LOTS, 63 TOWNHOME LOTS, AND T HREE (3) NON-RESIDENTIAL LOTS ON 63.78 ACRES LOCATED OFF HORTON HIGHWAY IN THE 5TH VOTING DISTRICT (1 -2026- 310). A ttachments 21-1 Preliminary Plat 21-2 Aerial Photograph 21-3 Applicant’s Request for Revised Concept Plan Conditions 21-4 Revised Review Memo from County’s Traffic Consultant 21-5 Original Review Memo from County’s Traffic Consultant A rea 63.78 acres Zoning Triune Character Area-3 (TCA-3) Triune Character Area-4 (TCA-4) Lots 59 Single-Family Lots 63 Townhome Lots Three (3) Non-Residential Lots Water Nolensville/College Grove Utility District Sewer Triune Sewer Facility Development Option Conservation Subdivision, Multi-Family and Non-Residential Chapter 1101 Status Triune Planned Growth Area (TPGA) Map and Parcel 113--- 05706, 05709, 05712, 07202 and 07203 F ile Number (1-2026-310) A Revised Concept Plan for this development wa s approved at the June 2026 meeting, which added three (3) non -residential lots and one (1) single-family residential lot. The currently approved Preliminary Plat depicts only the residential component of the development. The applicant is now requesting approval of a revised Preliminary Plat in order to incorporate both the residential and non -residential components of the development into a single Preliminary Plat. The revised Preliminary Plat is consistent with that depicted on the revised Concept Plan. D uring Concept Plan review, a Traffic Impact Analysis was performed by the applicant and reviewed by the County’s Traffic Consultant. Numerous roadway improvements were required in association with the development, and the construction of these improvements is currently underway. A s a condition of approval, the applicant is required to install a traffic signal at the intersection of Horton Highway and Malac hi Lane before the submittal of the Final Plat containing the 25 th lot. At this time, the applicant is requesting modification of this Item 21—Page 2 of 3 Reviewer: JYJ Date: 8/13/2026 condition to allow the submittal of a Final Plat containing up to the 30th lot in Triune East (this Item) and up to the 54 th lot in Triune West, which appeared as Item 20 on this agenda, for a total of up to eighty -four (84) lots. The applicant has submitted a memo documenting this request (See Attachment 21 -3), and this memo h as been reviewed by the County’s Traffic Consultant (See Attachment 21 -4). The County’s Traffic Consultant has noted allowing the applicant to submit Final Plats for the eighty -four (84) lots prior to construction of the signal at Horton Highway and Mal achi Lane will not result in a significant traffic impact to the surrounding roadway network. Therefore, the County’s Traffic Consultant has recommended the modification of the condition to allow the submission of a Final Plat containing up to the 30 th lot in Triune East, and that the residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane has been installed and is operational. Staff recommends approval of the Pre liminary Plat with the following conditions, which shall be addressed in conjunction with Final Plat consideration: 1. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 31 st lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 2 1-4 and 21-5) shall be completed to the satisfaction of the Tennessee Department of Transportation; 2. Except as noted in Number 3 below, prior to the submittal of th e Final Plat containing the 31st lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 2 1-4 and 2 1-5) shall be completed to the satisfaction of the Williamson County Highway Superintendent; 3. As specified by the County’s Traffic Consultant, the i nstallation of traffic signals and construction of the right turn deceleration lanes on Horton Highway at the I- 840 Eastbound and Westbound Ramps shall be completed/constructed prior to the issuance of building permits for any of the non -residential land uses; 4. The residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane has been installed and is operational; 5. At eighty -five percent (85%) build -out, Malachi Lane shall be repaved in its entirety, as required by the Williamson County Highway Department; 6. Prior to the submittal of the first Final Plat, the required Zoning Certificate for the wastewate r treatment and disposal system shall be submitted, and all conditions associated with the wastewater site plan approval must be satisfied; Item 21—Page 3 of 3 Reviewer: JYJ Date: 8/13/2026 7. Prior to consideration of Final Plat approval, the applicant shall submit HOA documents for review and approval by t he County Attorney’s office. The HOA documents must address the greenway easement, the maintenance and operation of t he private roads and gate that meet the standards , and requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents must be submitted with the Final Plat, and the approved HOA documents must be recorded concurrently with the recording of the Final Plat; 8. A permit for the security gate will need to be obtained prior to its installation, and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance must be met; 9. Prior to the submittal of any Final Plat in which a greenway is located, the 12 - foot-wide paved multi-modal greenway trail should be constructed; 10. Establishment of a performance bond for roads, d rainage and erosion control; 11. Establishment of a performance bond for water improvements in favor of Nolensville/College Grove Utility District; 12. Establishment of a performance bond for the wastewater collection system; 13. Submission of landscaping plans and es tablishment of a performance bond for landscaping improvements; 14. Execution of Performance Agreements for the above -referenced sureties; 15. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and 16. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. 35' LDSB & MBSL 35' LDSB 25' LDSB 35' LDSB 30' MBSL 10' MBSL 30' MBSL 10' MBSL 10' MBSL 10' MBSL 30' MBSL 35' MBSL 15' LDSB 15' LDSB 15' LDSB 25' LDSB 15' LDSB WET WEATHER CONVEYANCE Red Oak 48" Red Oak 34" Hollow POND D 0+00 0+00 0+53 POND A POND B POND C 0+00 0+00 0+35 HENRY HORTON HIGHWAY 35' LDSB 35' LDSB (PRIVATE) ALLEY (PRIVATE) ALLEY (PRIVATE) ALLEY (PRIVATE) ALLEY 24 25 22 23 21 31 30 29 28 26 24 25 27 22 23 21 31 30 29 28 26 20 17 9 1 16 8 15 7 14 6 13 5 12 4 19 11 3 18 10 2 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 122 121 120 119 88 90 91 92 93 94 97 96 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 115 116 117 118 (PRIVATE) ALLEY (PRIVATE) ALLEY (PRIVATE) ALLEY (PRIVATE) ALLEY 71 89 95 114 * * ** * * * * * * * * * * * * * * * * * * * * * * * * 50-FT WATERWAY NATURAL AREA (WNA) (STR-1) 50-FT WATERWAY NATURAL AREA (WNA) 50-FT WATER NATURAL AREA (STR-3) WETLAND AREA (WTL-2) 50 FT BUFFER WETLAND AREA (WTL-1) 50 FT BUFFER "UNT to NELSON CREEK" STREAM (STR-2) "UNT to NELSON CREEK" STREAM (STR-2) 50-FT WATERWAY NATURAL AREA (STR-2) NELSON CREEK (STR-1) WET WEATHER CONVEYANCE WITH DRAINAGE AREA GREATER THAN 5 ACRES (WWC-1/UDF-1) 25 FT DRAINAGE EASEMENT WETLAND AREA (WTL-3) * * * * * * TCA3 TCA2 TCA3 TCA4 TCA3 TCA2 TCA3TCA4 TCA3 * * * TCA4 32 33 34 35 37 38 40 39 36 41 42 43 44 45 46 47 48 * * 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 POND F 30' MBSL 25' LDSB 15' LDSB 10' MBSL 15' LDSB PRIVATE ALLEY PRIVATE ALLEY 64 65 66 67 68 69 70 10' MBSL TAIL SHOT ROAD (PRIVATE DRIVE) 15' LDSB Parcel Table Lot # 124 125 126 Area 45626.64 49091.53 47398.83 123 ACRES 1.047 1.127 1.088 50' OPEN SPACE SET ASIDE 15' LDSB MULTI-FAMILY PARENT PARCEL OS 7 MULTI-FAMILY PARENT PARCEL OS 9 124 125 126 Parcel Table Lot # OS 1 OS 2 OS 3 OS 4 OS 5 Area (SF) 26409.14 20368.65 550221.76 20806.62 396405.80 Area (AC) 0.61 0.47 12.63 0.48 9.10 OS 6 91287.20 2.10 OS 7 25091.20 0.58 OS 8 40381.17 0.93 OS 9 23690.55 0.54 OS 10 104292.07 2.39 OS 11 202946.66 4.66 OS 12 9645.12 0.22 MULTI-FAMILY PARENT PARCEL OS 6 MULTI-FAMILY PARENT PARCEL OS 8 MULTI-FAMILY PARENT PARCEL OS 9 OS 1 OS 2 OS 3 OS 5 OS 4 30' MBSL 15' LBSD 30' MBSL 35' MBSL 35' MBSL 50' MAX FRONT MBSL 50' MAX FRONT MBSL 35' MBSL 50' MAX FRONT MBSL 35' LDSB 35' LDSB SCALE: 1"=200' SURVEY DIVISION 214 Centerview Drive Suite 300 Brentwood, TN 37027 615.370.8500 615.370.8530 woldae.com Contact John Powell Ashby Communities, LLC. P.O. Box 190 Arrington, TN 37014 (615) 496-8681 SITE ADDRESS: 8030 hORTON HWY Arrington, TN 37014 06 91 .SSE ET NN NEE O CRITICAL LOTS: PROPOSED SINGLE FAMILY LOTS THAT HAVE EXISTING CRITICAL SLOPES ARE INDICATED WITH THIS SYMBOL. AN ENGINEERED SITE PLAN SHALL BE SUBMITTED AND APPROVED BY WILLIAMSON COUNTY ENGINEERING DEPARTMENT. LOTS: 12, 13, 14, 15, 16, 19, 20, 21, 22, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, AND 59 ARE INDICATED AS CRITICAL SLOPE LOTS. ATTACHMENT 21-1 ATTACHMENT 21-2 July 20, 2026 Mr. Aaron Holmes, AICP - Planning Director Williamson County Planning Commission 1320 West Main Street Suite 400 Franklin, TN 37064 Re: Villages at Triune West & East – Request for Revised Concept Plan Conditions Williamson County, Tennessee Dear Mr. Holmes, We respectfully request that Williamson County allow for the submittal and approval of a phased final plat for the residential lots within the development to be served exclusively by the approved site driveway connections to Murfreesboro Road (S.R. 96) for both the Villages at Triune West and Villages at Triune East developments. This request is based on the Traffic Impact Study (TIS) prepared by Civil & Environmental Consultants, Inc. (CEC), revised February 2025, and is supported by updated intersection capacity analysis (CEC, July 2026) demonstrating that the proposed plats operate within the traffic volumes and levels of service those intersections were designed and analyzed to accommodate. The current conditions of approval associated with the development require that all of the offsite roadway improvements be installed and approved by TDOT prior to being able to submit for a Final Plat for more than 24 residential units from either the Villages at Triune West or East subdivisions. This is based on the assumption that the existing intersection of Horton Highway and Malachi Lane restricts what traffic can be discharged at that intersection under current unsignalized conditions. The developer is preparing to submit the first final plats for both the West and East sides in time to appear on the October 2026 Planning Commission meeting agenda. The proposed first final plats are as follows: • Villages at Triune West — First Final Plat: 54 residential units (mix of single-family and townhomes), to be submitted in advance of the October 2026 Planning Commission meeting. • Villages at Triune East — First Final Plat: 30 residential units (mix of single-family and townhomes), submitted on the same schedule for the October 2026 Planning Commission meeting. The timing of this request is driven by the construction schedule of the signalized intersection at Horton Highway and Malachi Lane, which is not anticipated to be complete and open to traffic until December 2026 — after the targeted October Planning Commission approval of these first final plats. As detailed in the following sections, the traffic analysis in this letter accounts for that interim condition and confirms that the S.R. 96 intersections can accommodate the proposed plats within the volumes already studied and approved. Additionally, if allowed and approved by the Planning Commission at the October 2026 meeting, the recording of the Final Plat and then construction of the homes within the plat can begin. It is anticipated that the homes from the first plat would not be fully constructed until well into 2027, with the traffic signal fully installed and operating. CURRENT CONDITIONS OF APPROVAL — RESIDENTIAL The Triune development received approval for the following residential program, as analyzed at full build-out in the CEC TIS: ATTACHMENT 21-3 Table 1 — Approved Residential Program Development Area Single-Family Townhomes Total Units Triune West 99 213 312 Triune East 58 64 122 Total 157 277 434 With respect to platting and access, the existing condition of approval limits residential development to a combined total of 24 residential lots across both the East and West sides prior to installation of the signalized intersection at Horton Highway (U.S. 31A/41A/S.R. 11) and Malachi Lane (the “Malachi Lane Signal”). This interim limit reflects the TIS assumption that the Malachi Lane Signal would be operational to serve as the principal access for Triune East and a significant secondary access for Triune West at the time residential occupancy commenced. BASIS FOR THIS REQUEST — INTERIM ACCESS DURING CONSTRUCTION The approved development includes a second primary access connection via the Malachi Lane Signal, which the TIS analyzed as the principal point of access for the Triune East site and a significant secondary access for Triune West. Construction of that signalized intersection is about to begin; however, it is not anticipated to be open to traffic until December 2026. During the interim period prior to the Malachi Lane Signal opening, the S.R. 96 site driveways will serve as the sole access connection for residential traffic on both the West and East sides of the development. Under this scenario, 100% of the vehicle trips generated by the platted residential units will be routed through the S.R. 96 intersections. The 24-lot interim limit would unduly constrain the initial development phase during the intervening period despite the availability of adequate capacity at the S.R. 96 site driveways, which were designed and analyzed to accommodate substantially higher volumes at full build-out. As demonstrated by the updated capacity analysis below, the requested 54 (West) and 30 (East) units can be accommodated at the S.R. 96 driveways during the interim period at acceptable levels of service. Once the Malachi Lane Signal is open, residential trips will distribute across all approved access points per the TIS distribution percentages, materially reducing the S.R. 96 share and permitting the platting of any remaining residential units without further constraint. TRIP GENERATION — REQUESTED UNITS Trip generation for the requested first final plats was prepared by CEC using ITE Trip Generation, 12th Edition (average rates), for Land Use Code 210 (Single-Family Detached Housing) and Land Use Code 215 (Single-Family Attached Housing / Townhomes). The results, which serve as the basis for the interim capacity analysis, are summarized below. Table 2 — Triune West First Final Plat (54 Units): Trip Generation Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total) Single-Family (210) 15 148 3 / 2 / 17 9 / 5 / 14 Townhome (215) 39 276 5 / 13 / 18 11 / 9 / 20 West Total 54 424 8 / 21 / 29 20 / 14 / 34 Table 3 — Triune East First Final Plat (30 Units): Trip Generation Land Use (ITE LUC) Units Daily AM (In/Out/Total) PM (In/Out/Total) Single-Family (210) 8 89 2 / 4 / 6 5 / 2 / 7 Townhome (215) 22 155 3 / 7 / 10 6 / 5 / 11 East Total 30 244 5 / 11 / 16 11 / 7 / 18 No internal capture or pass-by reductions were applied to the residential trip generation, consistent with the TIS treatment of the residential land uses. During the interim phase, 100% of these trips are assigned to the respective S.R. 96 site driveways, as reflected in the CEC analysis. INTERIM TRIP DISTRIBUTION During the interim phase, because no access is provided at Malachi Lane, 100% of the trips generated by the requested residential units are assigned to the respective S.R. 96 site driveways. These trips will follow the trip distribution from the original TIS and a figure has been provided in the attachments showing the percentage of trips assigned. The Triune West driveway lies approximately 1,600 feet west of the Horton Highway / S.R. 96 intersection, and the Triune East driveway approximately 2,300 feet east of it. The intersection therefore lies between the two driveways. Only West site trips traveling east, and East site trips traveling west, traverse the Horton Highway / S.R. 96 intersection — approximately 21 A.M. and 25 P.M. peak-hour site trips, or roughly 1% of the existing intersection volume. This distribution is reflected in the 2026 Build turning-movement volumes used in the capacity analysis below. INTERIM CAPACITY ANALYSIS — 2026 BUILD CONDITIONS At the County's request, CEC performed a peak-hour capacity analysis of the three study intersections that serve or are traversed by interim site traffic, using the Highway Capacity Manual, 7th Edition methodology in Synchro Version 12, consistent with the TIS. The interim (2026 Build) volumes were developed by adding the site trip generation above — assigned 100% via the S.R. 96 driveways per the interim access condition — to the 2026 No-Build turning-movement volumes from the TIS. The analysis reflects the committed turn-lane improvements at each S.R. 96 driveway that are currently under construction and will be finished by the time the first final plat will be submitted. Results for the weekday A.M. and P.M. peak hours are presented below. S.R. 96 Site Driveways (Unsignalized, Two-Way Stop Control) Both S.R. 96 site driveways operate at an overall intersection delay of less than one second per vehicle (LOS A) in both peak hours. The stop-controlled northbound site-exit approaches operate at acceptable levels of service with negligible queuing (95th-percentile queues of less than one vehicle). The Murfreesboro Road left-turn movements entering the driveways operate at LOS A–B. Table 4 — 2026 Build LOS & Delay: S.R. 96 Site Driveways Intersection / Movement AM LOS (Delay) AM 95% Q PM LOS (Delay) PM 95% Q West Dwy — WB Left (into dwy) A (8.1) 0 B (10.8) 0.1 West Dwy — NB Left (exit) E (36.0) 0.1 E (35.2) 0.1 West Dwy — NB Right (exit) B (10.5) 0.1 C (19.2) 0.1 West Dwy — NB approach C (15.4) — C (22.7) — Intersection / Movement AM LOS (Delay) AM 95% Q PM LOS (Delay) PM 95% Q West Dwy — Overall A (0.3) — A (0.3) — East Dwy — WB Left (into dwy) A (7.5) 0 A (8.8) 0 East Dwy — NB approach (exit) B (14.6) 0.1 C (16.4) 0.1 East Dwy — Overall A (0.2) — A (0.2) — The northbound left-turn movement at the West driveway reflects LOS E; this is typical of a low-volume minor-street left turn crossing a higher-volume arterial under stop control and involves only a handful of vehicles per hour (a 95th-percentile queue of less than one vehicle). It does not affect the overall driveway operation, which remains LOS A. Horton Highway / S.R. 96 (Signalized) The Horton Highway / S.R. 96 signalized intersection was analyzed under both the 2026 No-Build and 2026 Build (with 84 interim units) conditions. The results demonstrate that the interim plats do not degrade the overall operation of this intersection relative to the No-Build condition. In the A.M. peak hour, the overall intersection delay under the Build condition is essentially unchanged from — in fact marginally better than — the No-Build condition. In the P.M. peak hour, the overall level of service remains within one grade of the No-Build condition. Table 5 — Horton Hwy / S.R. 96: 2026 No-Build vs. 2026 Build (84 Units) Approach AM No-Build AM Build PM No-Build PM Build Murfreesboro Rd — Eastbound D (37.0) C (30.5) C (30.9) D (39.6) Murfreesboro Rd — Westbound F (92.5) F (93.9) C (28.3) C (26.3) Horton Hwy — Northbound E (65.7) E (56.9) C (27.1) C (30.0) Nolensville Rd — Southbound F (111.2) F (117.9) D (37.1) D (48.8) Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8) The westbound and southbound approaches reflect LOS F in the A.M. peak hour under both the No-Build and Build conditions. This is a pre-existing regional congestion condition at this intersection that is present with or without the interim plats; the addition of the 84 interim units does not change the overall A.M. level of service (LOS E in both cases) and in fact slightly reduces overall delay. As documented in the TIS, improvements at this intersection are tied to regional conditions and the broader Horton Highway corridor rather than to this residential phase. DISCUSSION OF INTERIM IMPACTS The updated CEC capacity analysis confirms that the requested interim plats can be accommodated during the period prior to installation of the Malachi Lane Signal without adverse operational impact at the study intersections: • S.R. 96 site driveways: Both driveways operate at overall LOS A in both peak hours, with 95th- percentile queues of less than one vehicle on the stop-controlled site-exit approaches. The committed turn-lane improvements accommodate entering and exiting movements without impeding S.R. 96 through-traffic. The interim volumes (29 West / 16 East in the A.M.; 34 West / 18 East in the P.M.) represent less than 3% of the existing S.R. 96 mainline traffic at each location. • Horton Highway / S.R. 96 signalized intersection: Only approximately 21 A.M. and 25 P.M. site trips traverse this intersection — roughly 1% of its total entering volume. The analysis confirms the interim plats do not degrade the overall level of service: the A.M. peak remains LOS E (with slightly lower overall delay than No-Build), and the P.M. peak remains within one grade of No- Build. The LOS F approaches present in the A.M. peak are pre-existing regional conditions independent of this residential phase. • Relationship to the analyzed full build-out: The TIS analyzed each of these intersections under the full build-out condition — the entire 434-unit residential program plus all commercial land uses — and identified the improvements necessary to maintain acceptable operations. The interim phase places only a small fraction of that analyzed volume on the network, entirely via the S.R. 96 driveways, and therefore operates well within the previously accepted envelope. CONCLUSION This letter documents the current residential conditions of approval, the specific interim plat modification requested (54 units West / 30 units East, all single-family and townhome product), the interim access configuration in which all site access is provided exclusively via the S.R. 96 driveways with no Malachi Lane access until the signal is complete, the trip generation for the requested units, and the updated CEC capacity analysis of the three study intersections. That analysis confirms that the S.R. 96 site driveways operate at overall LOS A, and that the Horton Highway / S.R. 96 signalized intersection is not degraded by the interim plats relative to the 2026 No-Build condition. All required roadway improvements at each S.R. 96 driveway are committed conditions of development approval. Upon completion and opening of the Malachi Lane / Horton Highway signalized intersection — anticipated December 2026 — residential trips will distribute across all approved access points consistent with the TIS, and the developer will plat all remaining units in accordance with the full build distribution model. We respectfully request that the Planning Commission revise the approved conditions to allow for the phased final plat approach described herein and are available to meet or provide any additional information at your convenience. Sincerely, Will Crunk, PE Crunk Engineering LLC 1 | P a g e MEMORANDUM To: Aaron Holmes, Williamson County Planning Department From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC Date: 8/5/26 Subject: Triune Mixed-Use – Requested Conditions of Approval Revisions Introduction The Triune Mixed -Use development includes a combination of residential and commercial components located at the intersection of Horton Highway (US 41/SR 11) and Murfreesboro Road (SR 96) in unincorporated Williamson County. Following submittal and review of a Traffic Impact Study (TIS) according to the County’s guidelines, the development was approved with conditions, and construction of the first development phase, which includes all residential components split on the east and west sides of Horton Highway, began in 2026. The conditions of approval placed on the development included multiple requirements specific to off-site transportation improvements and their timing relative to preliminary and final plat submittals. As residential lots continue to be submitted for preliminary and final plats, the off-site improvements recommended in the February 2025 TIS are being constructed as required. One specific condition of approval included construction of a traffic signal at the intersection of Horton Highway and Malachi Lane, which will serve as a primary access to both Triune East and West at full buildout. This signal was required to be constructed and operational before the 25 th residential lot was submitted for final plat based on the existing and projected traffic volumes at this intersection. According to the developer’s engineer, Crunk Engineering, construction of this signal has been delayed but is still on track to be completed by the end of 2026 , which the development team claims will be well in advance of any residential units being completed . Therefore, the applicant is requesting a change to the existing conditions of approval in order to adhere to their desired development timeline. More specifically, the applicant is requesting that they be allowed to submit final plats for 84 residential units (60 more than is currently allowed) prior to the traffic signal being constructed. The applicant has submitted a memo documenting this request, including supplemental traffic operational analysis to evaluate the potential interim condition in which 84 lots are constructed but access to Malachi Lane is not provided, routing all development-generated traffic through the two site accesses on Murfreesboro Road and the intersection of Horton Highway and Murfreesboro Road. ATTACHMENT 21-4 2 | P a g e Analysis Review In order to evaluate the proposed interim access condition, a small-scale traffic impact analysis was conducted with standard components – trip generation, trip distribution and assignment, and capacity analysis – all described below. • Trip Generation - The projected trip generation was calculated for both Triune East, which includes a proposed 15 single family homes and 39 townhomes, and Triune West, which includes a proposed 8 single family homes and 22 townhomes, for a combined 84 residential dwelling units. The trip generation calculations do not follow the latest version of ITE’s Trip Generation Manual, 12th Edition, as stipulated in the memo, nor do they use industry standard practice of using the fitted curve equations as appropriate; however, with the relatively low number of dwelling units proposed, the discrepancy in trips generated is unlikely to make a difference in the operational outcomes. • Trip Distribution and Assignment – Under the interim access condition, all trips generated by the additional 84 residential units would utilize the Triune East and Triune West accesses on Murfreesboro Road. According to the 2025 TIS, trips generated by the development were expected to be oriented as follows: o 25% of trips to/from I-840 WB ramps o 20% of trips to/from I-840 EB ramps o 20% of trips to/from the west on Murfreesboro Road o 15% of trips to/from the east on Murfreesboro Road o 10% of trips to/from south on Horton Highway o 10% of trips to/from north on Horton Highway/Nolensville Pike With access limited to Murfreesboro Road, trips would redistribute at the two accesses and at the signalized intersection of Horton Highway and Murfreesboro Road. The following turning movements would see higher volumes during peak periods: o Eastbound right turns on Murfreesboro Road at the Triune East access o Westbound left turns on Murfreesboro Road at the Triune West access o Northbound left and right turns on Horton Highway at the existing signal o Eastbound right and westbound left turns on Murfreesboro Road at the existing signal It should be noted that the northbound and southbound through volumes on Horton Highway at the existing Malachi Lane intersection will also increase with the redistribution of traffic volumes generated by the 84 residential units . While not included in the requested analysis, it can be anticipated that any additional through volume on the major street will increase delays for the minor street volumes that exist today. 3 | P a g e • Capacity Analysis – Capacity analysis was completed for both projected 2026 AM and PM peak hours under the interim access scenario. The analyses account for the conditioned off-site improvements at both Murfreesboro Road accesses as they will be complete prior to construction of any residential units. The volumes, traffic control, and intersection geometry utilized in the projected analyses are reasonably correct. Table 1 summarizes the level of service (LOS) and vehicular delay projected at the three study intersections under the 2026 background, or no-build, condition as well as the 2026 projected, or build, condition during which access to Malachi Lane is not provided and all residential trips for the proposed 84 residential units is routed through the Murfreesboro Road accesses. The capacity analysis addressed the AM and PM peak hours at three intersections: the existing signalized intersection of Horton Highway and Murfreesboro Road, and the two unsignalized Murfreesboro Road driveways serving Triune East and Triune West. The no- build condition reflects the intersection geometry, traffic control, and signal timing documented in the February 2025 TIS, and the build condition adds the redistributed trips from the interim access scenario described above. The two driveway intersection s are shown only under the build condition, since they do not exist without the development. One item in the capacity analysis should be noted. The signal timing at Horton Highway and Murfreesboro Road was not held constant between the no-build and build scenarios; the cycle length was shortened along with the retiming. In the AM peak hour, the overall cycle length dropped from approximately 190 seconds under no-build to approximately 150 seconds under build, and in the PM peak hour it dropped from approximately 103 seconds to approximately 88 seconds, even though the traffic volumes at this intersection are nearly identical between the two scena rios. Because the timing plan changed at the same time as the volumes, the delay and LOS differences reported for this intersection reflect the combined effect of both variables, and the operational impact of the additional 84 units cannot be isolated from the effect of the signal retiming. The shorter cycle s improve LOS for movements with excess capacity but push already -saturated movements, including the WB and SB through movements, further past capacity, worsening their delay and queuing. The net effect is a slight improvement in the AM peak, where the intersection was already failing, but a full LOS drop from C to D in the PM peak, where it previously was not. Setting aside the signal timing discrepancy at Horton Highway and Murfreesboro Road, the additional volumes generated by the interim access scenario are expected to have a limited effect on operations at the three study intersections. The two new driveways operate at LOS C or better for nearly all movements, with the exception of the northbound left turn at the Triune West driveway, which operates at LOS E in both peak hours and is expected for an unsignalized minor street approach movement along an 4 | P a g e arterial. The existing signalized intersection already operates at LOS E in the AM peak hour and LOS C to D in the PM peak hour under the no -build condition, and the incremental delay attributable to the added 84 units, apart from the timing changes discussed above, is small relative to the background condition. Only one movement, the northbound left turn, deteriorates in LOS between the no-build and build conditions during the PM peak hour. Given that this condition is temporary and will be resolved once the Malachi Lane signal is constructed, these results do not support a requirement for additional off -site infrastructure improvements to accommodate the interim access scenario. Table 1. Comparison of 2026 Background (No-Build) and Projected (Build) Peak Hour Operations Intersection/Movement LOS (Vehicular Delay in sec/veh) AM No-Build AM Build PM No-Build PM Build Murfreesboro Road and Horton Highway/ Nolensville Pike EB Left Turn E (76.0) E (58.0) C (23.3) C (21.5) EB Through D (45.2) D (37.9) D (36.6) D (52.5) EB Right Turn C (21.8) B (19.4) C (26.7) C (30.4) WB Left Turn D (42.6) C (34.5) C (27.9) C (26.0) WB Through F (98.6) F (101.9) C (28.4) C (26.5) WB Right Turn NB Left Turn F (100.9) F (87.2) C (27.5) D (37.0) NB Through C (31.7) C (27.6) C (26.9) C (25.9) NB Right Turn SB Left Turn D (46.3) D (38.1) C (23.7) C (21.2) SB Through F (113.7) F (120.9) D (38.9) D (52.5) SB Right Turn Overall Intersection E (78.5) E (75.8) C (31.0) D (37.8) Murfreesboro Road and Triune East Driveway WB Left Turn -- A (7.5) -- A (8.8) NB Left Turn -- B (14.6) -- C (16.4) Murfreesboro Road and Triune West Driveway NB Left Turn -- E (36.0) -- E (35.2) NB Right Turn -- B (10.5) -- C (19.2) WB Left Turn -- A (8.1) -- B (10.8) 5 | P a g e Conclusion Based on the review of the supplemental traffic operational analysis, allowing the applicant to submit final plats for up to 30 lots in Triune East and up to 54 lots in Triune West for a total of 84 residential units prior to construction of the Malachi Lane signal1 is not expected to result in a significant traffic impact to the surrounding roadway network. The interim access scenario, which routes all development-generated trips through the two Murfreesboro Road driveways and the existing signalized intersection at Horton Highway, results in relatively minor incremental delays at the existing signal beyond what is already occurring under background conditions. This condition is temporary by design and will be resolved once access from Triune East and West is provided via Malachi Lane. Therefore, the request to submit final plats for the 84 lots, up to 30 lots in Triune East and up to 54 lots in Triune West, is reasonable provided that the residential lots within Triune East and Triune West are not permitted to access Malachi Lane or the traffic signal is constructed, which the applicant's engineer indicates remains on track for completion by the end of 2026, well ahead of any residential units being constructed. Accordingly, I do not recommend requiring additional off-site infrastructure improvements as a condition of approving the applicant's request, and I recommend that residential lots in either Triune East or Triune West shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane is installed and operational in order to protect the County and existing traffic on Malachi Lane from added development traffic in the interim. Should you have any questions or need additional information, please contact me. Sincerely, Kayla Ferguson, PE, AICP Burch Transportation, LLC 1 The existing condition of approval limits residential development to a combined total of 24 residential lots across both Triune East and West prior to installation of the signal . 1 | Page MEMORANDUM To: Aaron Holmes, Williamson County Planning Department From: Kayla Ferguson, P.E., AICP; Burch Transportation, LLC Date: 3/3/2025 Subject: Triune Mixed-Use TIS Review Thi s memorandum provides the findings of the independent review of the Triune Mixed -Use TIS submitted to Williamson County Planning on 2/20/2025 for a concept plan submittal. The review focused on the following three items: consistency with assumptions discussed in the traffic study scoping and included in the executed MOUA, review of the traffic operational analyses, and evaluation of recommended infrastructure improvements. Based on this review, we identify any necessary modifications to the traffic study and/or the recommendations that ensure consistency with the County’s Traffic Study Guidelines and mitigate impacts of the proposed project. G eneral Project Information and Traffic Study Scope The Triune Mixed-Use development proposal includes a new development plan located on either side of Horton Highway (US 41A/SR 11) between Murfreesboro Road (SR 96) and I -840 in the Triune area of Williamson County. The proposed development plan is referred to as Triune East and Triune West based on its bifurcation via Horton Highwa y. The two sites will each include a mix of residential unit types and commercial space and have six total accesses proposed – two on Murfreesboro Road and four on Horton Highway. Based o n the proposed density and trip generation of the development, a Traffic Impact Study was required. A traffic study scoping call was conducted with the applicant’s traffic study preparer on August 21, 2024. The outcome of this meeting was an agreed upon set of assumptions and study parameters for the traffic study. Table 1 identifies key traffic study elements and an evaluation of their consistency with the agreed upon scope. As noted, the traffic study submitted accurately reflects the current concept plan and the scope as agreed upon in the MOUA. ATTACHMENT 21-5 2 | Page Table 1: Review of Traffic Study Scope Elements Project Characteristic Documented in Traffic Study Consistent with MOUA? Proposed Land Use and Density 342 single-family residential units 98 multifamily residential units 42,400 sf restaurant space 54,400 sf retail space 45,000 sf supermarket 16,000 sf hardware store 50,400 sf office space 318-room hotel Yes No Trip Generation AM: 1,184 total / 612 enter / 572 exit PM: 1,777 total / 938 enter / 839 exit Yes No Notes: Exact trip totals are higher than presented in MOUA, but calculations are appropriate and correct. Buildout and Background Growth Buildout Horizon: 2026 / 2031 Annual Growth Rate: 1.0% Site Specific Growth: Burns Property, Troubadour, Kings Chapel, Hardeman Springs, Fiddler’s Glen, and Patterson Road Development Yes No Study Area Segments: Murfreesboro Road; Horton Hwy Intersections: • Horton Highway / I-840 EB ramp • Horton Highway / I-840 WB ramp • Horton Highway / Murfreesboro Road • Horton Highway and Malachi Lane/Site Access • Horton Highway / Triune East Site Access • Horton Highway / Triune West Site Access • Malachi Lane / Site Access • Murfreesboro Road / Triune West Site Access • Murfreesboro Road / Triune East Site Access Yes No Notes: Additional site accesses were included to reflect changes in the site plan following the MOUA execution. Traffic Operational Analyses The operational analyses for the intersections and roadway segments within the study area were based on methods from Highway Capacity Manual. The following bullets highlight a review of the analysis as documented in the TIA: • Data to support the traffic analyses was collected from 7:00-9:00 AM and 4:00-6:00 PM on Thursday, September 5, 2024 when local schools were in session. • Based on the data collected and capacity analysis, there are multiple critical turning movements that operate at LOS E or worse during existing peak hour conditions. More specifically, minor street left turn movements on the I-840 eastbound and westbound ramps as well as multiple movements at the signalized intersection of Murfreesboro 3 | Page Road and Horton Highway/Nolensville Road all currently operate unacceptably during at least one if not both peak hours. • Background and projected capacity analysis is divided into two horizon years. The first represents a 2026 buildout year, which is expected to include all of the proposed residential density in the Triune East and Triune West developments. The second represents a 2031 buildout year, which is expected to include all of the non-residential density. • Continued growth in the region as well as this specific area of the County add significant peak hour volumes to the critical intersections over the 7-year buildout horizon. This causes already-failing movements to further deteriorate with significant increases in average vehicular delays during peak hours before construction of the Triune mixed-use development. The most significant delay is predicted for vehicles turning left from the stop-controlled I-840 eastbound ramp onto Horton Highway, averaging ~5 minutes per vehicle in the AM peak hour and ~27 minutes per vehicle in the PM peak hour in 2031. • Addition of the proposed Triune Mixed-Use project causes significant increases in delays for aforementioned critical turning movements at existing intersections. Table 2 highlights the specific scenario in which critical turning movements are expected to operate at LOS E (indicated with green shading) and the corresponding vehicular delay expressed in seconds per vehicle. For the 2026 and 2031 projected scenarios, the additional delay added by the proposed project is shown in parentheses. • As shown in Table 2, the intersection of Horton Highway and Murfreesboro Road has multiple movements that already operate at LOS E, but the relative increase of delay caused by the Triune Mixed-Use development is low. For example, the proposed development is expected to add a maximum of 36 seconds to any of these movements, specifically the westbound through/right turn movement. It should be noted that TDOT has plans to eventually widen the Murfreesboro Road in the vicinity of the Triune Mixed-Use project. The widening of Murfreesboro Road will also include capacity improvements at this intersection that will help to alleviate the existing and projected delays. However, no funding is allocated for this project and the anticipated completion is, therefore, unknown. • By contrast, delays added to the unsignalized I-840 ramps with completion of the proposed project are significant. Traffic signal warrant analyses were conducted to determine if and when traffic volumes would justify the need for traffic signals at these locations. According to methodology set forth in the MUTCD and the typical requirement to satisfy an 8-hour volume warrant on State Routes like Horton Highway, both of these ramp intersections warrant traffic signal control under existing conditions. Further, the study notes that additional capacity will be needed along Horton Highway, specifically right turn lanes onto the I-840 ramps, in addition to traffic signal control to mitigate projected delays. 4 | Page Table 2: Summary of Critical Existing Intersection Operations Intersection Critical Movement Peak Hour Average Delay in Seconds/Vehicle (Development-Induced Increase) 2024 Existing 2026 Background 2031 Background 2026 Projected 2031 Projected Horton Highway and Murfreesboro Road NB Left Turn AM 77 sec 101 sec 114 sec 96 sec (-5) 132 sec (+18) PM SB Through/Right Turn AM 80 sec 114 sec 122 sec 124 sec (+10) 145 sec (+23) PM 56 sec (+17) 55 sec (+11) WB Through/Right Turn AM 77 sec 99 sec 118 sec 107 sec (+8) 154 sec (+36) PM EB Left Turn AM 76 sec 89 sec 66 sec (-10) 83 sec (-6) PM EB Through/Right Turn AM PM 60 sec (+23) 52 sec (+10) I-840 WB Ramps and Horton Highway WB Left Turn AM 65 sec 85 sec 373 sec (+308) 761 sec (+676) PM 38 sec 126 sec 171 sec 712 sec (+586) 1,193 sec (+1,022) WB Right Turn AM 38 sec 38 sec (+0) 161 sec (+123) PM I-840 EB Ramps and Horton Highway EB Left Turn AM 96 sec 215 sec 305 sec 489 sec (+274) 1,754 sec (+1,449) PM 552 sec 1,177 sec 1,613 sec 2,444 sec (+1,267) 6,655 sec (+5,042) 5 | Page • Based on the presented traffic volumes and the methodologies in NCHRP Report 457 – Evaluating Intersection Improvements: An Engineering Study Guide , turn lanes are warranted at the following site accesses during different build years (shown in parentheses) for the proposed development: o Northbound right turn lane on Horton Highway at southern Site Access (2026) o Southbound right turn lane on Horton Highway at southern Site Access (2031) o Northbound right turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Northbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Southbound right turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Southbound left turn lane on Horton Highway at Malachi Lane/Site Access (2026) o Eastbound right turn lane on Murfreesboro Road at West Site Access (2026) o Westbound left turn lane on Murfreesboro Road at West Site Access (2026) o Westbound left turn lane on Murfreesboro Road at East Site Access (2031) • Deceleration lengths for the recommended turn lanes are based on a 35-mph speed, which is 10 mph lower than the 45 -mph posted speed limit south of the site on Horton Highway and on Highway 96 . This is typical in constrained situations where vehicles are assumed to begin decelerating in the adjacent through lane. North of the project site, the posted speed limit is 35 mph on Horton Highway near the Highway 96 traffic signal. • Recommended storage lengths were sourced from the Highway Capacity Manual based on facility type and context as well as TDOT’s review of the preliminary design plans. The recommended storage lengths are expected to be sufficient to accommodate projected queues output from the capacity analysis. • Intersection sight distance was not evaluated in the TIS as requested in the scoping call by TDOT but were later provided with proposed site plans submitted to the County for review. These exhibits show the available sight distance at the proposed intersections of Highway 96 and the Triune East and Triune West accesses. Based on examination of those exhibits, sufficient intersection sight distance is available at these locations. Exhibits were not provided for the site accesses on Horton Highway; however, based on street view imagery, it is anticipated that intersection sight distance at these locations is sufficient. • Per TDOT’s request, SIDRA analysis was conducted for the intersection of Horton Highway and Malachi Lane/Site Access. The significant volume northbound and southbound on Horton Highway causes a single lane roundabout to operate at LOS F with significant queues under projected con ditions. A multilane roundabout that provides additional capacity for these movements would improve LOS and resolve queue issues; however, this was not recommended in the TIS based on potential property restrictions. 6 | Page Based on the review of traffic study, it appears that the operational analyses are based on reasonably correct peak hour volumes, intersection laneage, and traffic control. Recommended Infrastructure Improvements Based on the operational analysis as well as signal and turn lane warran ts, the following infrastructure improvements are recommended in the TI S. The timing of each improvement is denoted in parentheses. For each set of improvements, a response is noted below. 1. Murfreesboro Road with Triune East Site Driveway (Phase 1 – 2026 and Phase 2 – 2031) o Implement unsignalized intersection control (stop on minor street approach) o Construction of northbound Site Driveway shared left/right turn lane o Construction of westbound Murfreesboro Road left turn lane (595 feet total length including taper, deceleration and storage) Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for improvements at this intersection should be approved by TDOT and Williamson County prior to application of any building permits for Phase 2, which includes all non-residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before issuance of building permits for Phase 2. 2. Improvements at Horton Highway and Murfreesboro Road (Phase 1 – 2026 and Phase 2 – 2031) o Optimization of traffic signal timings including cycle lengths and splits Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. This should be completed following completion of both phases in 2026 and 2031. 3. Murfreesboro Road with Triune West Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (stop on minor street approach) o Construction of westbound Murfreesboro Road left turn lane (595 feet total length including taper, deceleration and storage) o Construction of eastbound Murfreesboro Road right turn lane (360 feet total length including taper, deceleration and storage) o Site Driveway northbound left turn lane (100 ft of storage plus taper) and northbound right turn lane Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for these turn lane improvements should be approved by TDOT and Williamson County prior to submittal of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Con struction of all 7 | Page recommended turn lanes should be completed before submittal of the final plat for Phase 1. 4. Improvements at Horton Highway and Malachi Lane/Site Access (Phase 1 – 2026) o Implementation of signalized intersection control o Construction of Horton Highway northbound left turn lane (355 feet total length including taper, deceleration and storage) and northbound right turn lane that extends through the upstream proposed driveway. o Construction of Horton Highway southbound left turn lane (460 feet total length including taper, deceleration and storage) and southbound right turn lane ( 360 feet total length including taper, deceleration and storage) o Construction of eastbound Site Driveway to include one left turn lane (100 ft of storage plus taper), one through lane, and one right turn lane (100 ft of storage plus taper) o Construction of westbound Malachi Lane left turn lane (200 ft of storage plus taper) and westbound through/right turn lane o Due to the proximity of Malachi Lane with the existing gas station and proposed Triune East/West Site Driveway s, northbound turn lanes will extend beyond those driveways. Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. With implementation of traffic signal control, left turn movements should all be protected-permitted phasing and should include right turn overlaps where applicable. Design and construction plans for improvements at this intersection should be approved by TDOT and Williamson County prior to submittal of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before submittal of the final plat for lots 1 through 24 in Phase 1. The installation of traffic signal control should be completed before submittal of the final plat for the 25 th lot. 5. Horton Highway with Triune East/West Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (stop on minor street approach) o Right-in-right-out (RIRO) operation for both East and West site driveways o Construction of Horton Highway northbound right turn lane (255 feet total length including taper, deceleration and storage) and southbound right turn lane ( 230 feet total length including taper, deceleration and storage) Review Evaluation: This recommended improvement is consistent with the analysis presented and expectations. Design and construction plans for these turn lane improvements should be approved by TDOT and Williamson County prior to submittal 8 | Page of the preliminary plat for Phase 1, which includes all residential components of the Triune East and Triune West sites. Construction of all recommended turn lanes should be completed before submittal of the final plat for Phase 1. 6. Horton Highway with I-840 EB and WB Ramps (Phase 1 – 2026) o The installation of traffic signal control should be implemented but should not be the sole responsibility of the developer for the Triune development. Instead, solutions with TDOT and Williamson County regarding funding of these regional improvements should be explored before full build -out of the Triune Development. However, construction of residential components for Phases 1-3 of Triune East and West should be permitted under existing traffic control with coordination with TDOT and Williamson County. Review Evaluation: As noted in the TIS analyses, the existing unsignalized intersections of Horton Highway and the I-840 EB and W B Ramps both operate unacceptably under existing peak hour conditions. The minor street stop - controlled ramp movements experience heavy delays due to the high northbound and southbound volumes on Horton Highway. Eight-hour volume warrants as outlined in the MUTCD warrant the installation of a traffic signal at these locations in 2024. The need for this signalization is further compounded with additional background development growth and the proposed Triune Mixed-Use development. Based on coordination with TDOT, the need for signalization and additional capacity at t hese ramps has already been identified through the RSAR safety process. However, funding has not been allocated for the design or construction in TDOT’s current 3 -Year Plan that extends through 2027. Therefore, the installation of traffic signals and right turn deceleration lanes on Horton Highway should be completed before building permits are issued for any non -residential land uses in Phase 2 of the Triune Mixed -Use development. In addition and as recommended in the TIS, the Triune Mixed -Use development should coordinate with TDOT and Williamson County to participate in the funding of these improvements. 7. Malachi Lane with Triune East Site Driveway (Phase 1 – 2026) o Implement unsignalized intersection control (all-way stop) Review Evaluation: Based on the projected volumes at this intersection and historic crash data, all-way stop control is unlikely to be warranted. Therefore, it is recommended that this intersection be designed and constructed as a two-way stop intersection with stop-control implemented for the northbound approach of the Triune East access. 9 | Page All of the above infrastructure improvements should be constructed in tandem with the specific phase identified above. For additional clarity, the following figures highlight the specific improvements and their timing. 10 | Page Figure 1: Location of Recommended Off-Site Improvements per TIS Recommendations and 3rd Party Review 11 | Page Figure 2a: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review 12 | Page Figure 2b: Summary of Recommended Off-Site Improvements and Associated Timing per TIS Recommendations and 3rd Party Review 13 | Page Conclusion – Study Acceptance The Triune Mixed-Use TIS submitted February 2025 includes all of the typically required traffic study components and identifies reasonable and beneficial infrastructure improvements to be made as a result of the proposed development . At this time, we recommend acceptance of the current traffic study and its recommendations . Timing of the various improvements associated with the various development phases should be incorporated into the conditions of approval as noted in the review comments. Should you have any questions or need additional information, please contact me. Sincerely, Kayla Ferguson, PE, AICP Burch Transportation, LLC Item 22—Page 1 of 2 Reviewer: OCW Date: 8/13/2026 ITEM 22 FINAL PLAT REVIEW FOR THE GROVE SUBDIVISION, SECTION 18, CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND VOTING DISTRICT (1-2026-414). Attachment 22-1 Final Plat 22-2 Aerial Photograph Area 9.02 acres Lots 11 Zoning Rural Development-1 (RD-1) Water Milcrofton Utility District Sewer Nontraditional Wastewater Treatment and Disposal System Development Option Conservation Subdivision Chapter 1101 Status Rural File Number (1-2026-414) This Section consists of a portion of Phase 2, and Phase 14 . The applicant is now requesting Final Plat approval of Section 18 of the developme nt, which contains eleven (11) lots and 3.33 acres of Open Space. As this section is internal no landscaping is required. The plat is consistent in layout with that depicted on the Preliminary Plat. Staff recommends approval of the Final Plat with the following conditions: 1. Establishment of a mai ntenance bond for water improvements in favor of Milcrofton Utility District in the amount of $44,332.30 ; 2. Per the recommendation of the County’s Wastewater Consultant, establishment of a performance bond for the wastewater collection system in the amount of $137,924.71; 3. Execution of performance agreements for the above referenced sureties; 4. The approved HOA documents must be recorded concurrently with the recording of the Final Plat; 5. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and Item 22—Page 2 of 2 Reviewer: OCW Date: 8/13/2026 6. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. 2021 2022 2023 2024 4035 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3001 2014 2013 2015 2016 2017 2018 1 2 3 4 5 6 7 8 9 10 11 OPEN SPACE 1 WILDINGS BOULEVARD WILD HERON WAY NATIVE PONY TRL OPEN SPACE 2 5195 5191 5187 5183 5179 5175 5201 5205 5209 5213 5217 5221 5223 The Grove P1 Cover Sheet Sheet Schedule Final PlatP3 Final PlatP2 N S WE Civil EngineeringLand Planning & ZoningLand Surveying 516 Heather PlaceNashville, TN 37204 (615) 297-5166 Dale & Associates JAMES E. C A M PBELL,II2861.ON E ESSENNE T VX I AGRICULTURE EC R E M M O C REGISTERED LAND SURVEYOR D&A PROJECT #11053 SHEET: P1 SHEET 1 OF 3 07/20/2026 P2 P3 Section 18 Final Plat of Phase 2 and Phase 14 Preliminary Plat Portion of Parcel 29.02 on Map 135 and All of Parcels 29.08 and 29.10 On Map 142 Total Area: 9.02 Acres, 392,854 Square Feet Date: July 20, 2026 Certificate of Survey I hereby certify that the subdivision plan shown and described hereon is true and correct survey to the accuracy required by the Williamson County, Tennessee Regional Planning Commission and that the monuments have been or will be placed as shown hereon, to the specifications of the Subdivision Regulations, as approved by the County Engineer. James E. Campbell, II Revised Date Certificate of Ownership I (we) hereby certify that I am (we are) the owner(s) of the property shown and that I (we) hereby adopt this plan of subdivision with my (our) free consent, establish the minimum building restriction line, and that offers of irrevocable dedications for all public streets, utilities and other facilities have been filed as required by these regulations. OwnerDate Certificate of Approval of Utility Systems I hereby certify that the following utility systems outlines on the final subdivision plat entitled have been installed in accordance with current, local, and/or state government requirements or that a surety bond has been posted with the Planning Commission to assure completion of all required improvements in case of default. Also, I certify that the hydraulic design criteria specified in Section 5.5 of Williamson County Subdivision Regulations have been met. Date - Water SystemMike Jones - Microfton Date - Sewer System Charles Hyatt - TN Wastewater System Certificate of Approval for Recording I hereby certify that the subdivision plat shown hereon has been found to comply with the Subdivision Regulations for the Williamson County, Tennessee, with the exception of such variances, if any, as are noted in the minutes of the Planning Commission, and that it has been approved for recording in the office of the County Register. DateSecretary, Planning Commission GENERAL NOTES: 1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE. 2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK 5382, PAGE 78. 3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN. 4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135. 5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983 (NAD83). 6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS THAT A CURRENT TITLE EXAMINATION MAY REVEAL. 7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA. 8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA. 9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS. 10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN: ·MAP NUMBER: 47187C0380G ·EFFECTIVE DATE: 12/20/2024 11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION, KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS SITE. 12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT. 13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS (WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN. 14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1 FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT. 15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES. 840 McCRORY CREEK Harpeth River Starnes Creek Eudailey- Covington Rd Covington Rd Eudailey- Arno Rd Arno-CollegeGrove Rd Bethesda Arno Rd Nathan Smith Rd Arno Rd Site Vicinity Map NTS Site N S WE 1000100200 GRAPHIC SCALE 1" = 100' ATTACHMENT 22-1A EXISTING RESIDENCE WILDINGS BOULEVARD NATIVE PONY TRL OPEN SPACE 1 126,607 SQ. FT. 2.91 ACRES 2018 2019 2020 2021 2022 2023 2024 3002 3003 3004 3005 3006 3007 3008 3010 3001 OPEN SPACE 2 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 12'' 1 2 3 4 5 6 7 (50' PUBLIC ROW) THE GROVE PHASE 1, SECTION 2PLAT BOOK P56, PAGE 29 THE GROVE PHASE 2, SECTION 3 PLAT BOOK P58, PAGE 5 EXISTING BUILDING 30' REAR MBSL (TYP) 6.02' 30' REAR MBSL (TYP) 35' FRONT MBSL (TYP) 10' SIDE MBSL (TYP) WILD HERON WAY HATCHED AREA REMOVED ON OPEN SPACE 4 RECONFIGURATION PLAT BOOK P88, PAGE 53 20' PUBLIC UTILITY EASEMENT 3009 MATCHLINE MATCHLINE HATCHED AREA REMOVED ON OPEN SPACE 4 RECONFIGURATION PLAT BOOK P88, PAGE 53 8 9 S 74°37'41" E 222.53' S 74°37'41" E 219.87' S 59°45'01" E 209.46' 165.00' S 44°08'09" E165.00' S 28°31'22" E165.00' S 12°51'36" E 165.00' S 12°51'45" E 165.00' S 77°08'15" W 168.12' N 33°41'26" W 518.28' N 14°12'16" E 9 19.28'144.52' 130.74' 74.00' 21.51' N 77°08'07" E 128.42' N 69°18'24" E 84.46' N 53°40'14" E 84.21' 128.42' 39.70' N 38°03'29" E 84.22' 87.45' S 21°40'28" E S 74°31'49" E 624.69' 103.26' C3 C4 C5 C6 C7 S 15°23'52" W 426.67' S 70°32'25" E 226.17' 119.25' 128.36' 130.72' 35' FRONT MBSL (TYP) EXISTING DRIVETO BE REMOVED EXISTING BUILDINGTO BE REMOVED 20' PUBLIC UTILITY EASEMENT 10' SIDE MBSL (TYP) 42.32' S 74°36'08" E227.76' THE GROVE PHASE 2, SECTION 3 PLAT BOOK P58, PAGE 5 50' PERIMETER BUFFERYARD CLYDE D. LYNCH MARITAL TRUST - LOUISE GILLESPIE LYNCH 2 YEAR QUALIFIED PERSONAL RESIDENCE TRUST MAP 135, PARCEL 29 DEED BOOK 6624, PAGE 296 PROPOSED 4" FORCE MAIN 25' DRAINAGE EASEMENT 20' PUDE & MTE EASEMENT 44.46' 20' PUDE P2 P3 CLYDE D. LYNCH MARITAL TRUST - LOUISE GILLESPIE LYNCH 2 YEAR QUALIFIED PERSONAL RESIDENCE TRUST MAP 135, PARCEL 29 DEED BOOK 6624, PAGE 296 OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1 PLAT BOOK P88, PAGE 40 OPEN SPACE 4 REVISED PLAT THE GROVE PHASE 1 SECTION 1 PLAT BOOK P88, PAGE 40 5195 5191 5201 5205 5209 5213 5217 5221 5223 EXISTING 8" FORCE MAIN Civil EngineeringLand Planning & ZoningLand Surveying 516 Heather PlaceNashville, TN 37204 (615) 297-5166 Dale & Associates D&A PROJECT #11053 SHEET: P2 SHEET 2 OF 3 N S WE 50050100 1-800-351-1111 E SSENNT EE E LA S L TSY C ONE M, . ICN!GI FEB POTS A -C LL RO E UOY D GRAPHIC SCALE 1" = 50' BEARINGS ARE RELATIVE TO THE TENNESSEE STATE PLANE COORDINATE SYSTEM NAD83 (CORS96) EPOCH 2002 = 5/8" CAPPED IRON ROD (NEW) "DALE & ASSOCIATES" = 5/8" IRON ROD (OLD) "DALE & ASSOCIATES" *UNLESS OTHERWISE NOTED = FIRE HYDRANT = CURB INLET = WATER LINE = SIDEWALK W = HEADWALL = SEWER FORCE MAIN LINE = OVERHEAD UTILITY LINEOH FM = AREA DRAIN Prepared for: The Grove AREA TABLE 840 McCRORY CREEK Harpeth River Starnes Creek Eudailey- Covington Rd Covington Rd Eudailey- Arno Rd Arno-CollegeGrove Rd Bethesda Arno Rd Nathan Smith Rd Arno Rd Site Vicinity Map NTS Site N S WE Lot # Square Feet Acres 121,189 0.49 217,863 0.41 317,809 0.41 417,811 0.41 521,869 0.50 628,919 0.66 730,561 0.70 825,208 0.58 922,037 0.51 1022,614 0.52 1120,485 0.47 OPEN SPACE 1 18,107 0.42 OPEN SPACE 2 126,607 2.91 TOTAL 392,854 9.02 CURVE TABLE CURVE DELTA ANGLE RADIUS ARC LENGTH CHORD BEARING CHORD LENGTH C12°52'30" 525.00'26.34'S 06°32'13" E26.34' C2 C3 C4 14°51'07" 475.00' 123.13'S 22°49'26" W122.78' C5 15°36'52" 475.00' 129.45'S 38°03'25" W129.05' C6 15°36'47" 475.00' 129.44'S 53°40'14" W129.04' C7 15°39'37" 475.00' 129.83'S 69°18'26" W129.42' 14°12'24" 475.00' 117.78'S 00°52'16" E117.48' 9°09'56" 475.00'75.98'S 10°48'55" W75.90' PUDE = PUBLIC UTILITY & DRAINAGE EASEMENT The Grove Section 18 Final Plat of Phase 2 and Phase 14 Preliminary Plat Located in the College Grove Community, and is the property of TVG Tennessee I, LLC, Book 5382, Page 78 and Book 6528, Page 732, Registers Office Williamson County, Tennessee 6437 Wildings Boulevard College Grove, Tennessee 37046 Map 142, Parcel 29.08 Map 142 Parcel 29.10 Book 5382, Page 78 and Map 135, Parcel 29.02 Book 6528, Page 732 Drawn By:NH Checked By: EC Scale: 1" = 50' Date: 06/01/2026 R1 07/20/2026 Percentage 4.61 % 32.23 % GENERAL NOTES: 1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE. 2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK 5382, PAGE 78. 3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN. 4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135. 5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983 (NAD83). 6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS THAT A CURRENT TITLE EXAMINATION MAY REVEAL. 7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA. 8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA. 9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS. 10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN: ·MAP NUMBER: 47187C0380G ·EFFECTIVE DATE: 12/20/2024 11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION, KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS SITE. 12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT. 13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS (WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN. 14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1 FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT. 15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES. Revisions: R1 07/17/2026 ·Addressed Williamson County Comments posted on 07/13/2026, Project ID 2180481. ATTACHMENT 22-1B 3007 3008 3010 3011 W 12'' W 12'' W 12'' W 12'' W 12'' W 6 7 EXISTING BUILDING 30' REAR MBSL (TYP) 6.02' HATCHED AREA REMOVED ON OPEN SPACE 4 RECONFIGURATION PLAT BOOK P88, PAGE 53 20' PUBLIC UTILITY EASEMENT 3009 MATCHLINE MATCHLINE HATCHED AREA REMOVED ON OPEN SPACE 4 RECONFIGURATION PLAT BOOK P88, PAGE 53 8 9 10 11 WILDINGS BOULEVARD (50' PUBLIC ROW) CURVE C1 C2 C3 C4 C5 C6 C7 S 74°37'41" E 222.53' S 74°37'41" E 219.87' N 14°12'16" E 9 19.28'144.52' 130.74' 74.00' 103.26' 124.19' 153.48' C1 C2C3 97.53' S 07°58'28" E 253.93' S 15°23'52" W 426.67' N 82°01'32" E 154.69' N 82°01'32" E 201.57' S 70°32'25" E 226.17' 120.67' 115.00' 18.26' 119.25' 128.36' 130.72' 35' FRONT MBSL (TYP) 20' PUBLIC UTILITY EASEMENT EXISTING DRIVETO BE REMOVED EXISTING BUILDINGTO BE REMOVED 10' SIDE MBSL (TYP) 30' REAR MBSL (TYP) 4035 OPEN SPACE 2 THE GROVE, REVISED FINAL PLAT, PHASE 1, SECTION 1 PLAT BOOK P59, PAGE 53 OPEN SPACE 2 18,107 SQ. FT. 0.42 ACRES NATIVE PONY TRAIL (50' PUBLIC ROW) OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1 PLAT BOOK P88, PAGE 40 EXISTING 30" HDPE OPEN SPACE 4 REVISED PLAT, THE GROVE PHASE 1 SECTION 1 PLAT BOOK P88, PAGE 40 N 79°09'29" E 87.45' 80.14' 42.32' S 74°36'08" E227.76' S 84°13'19" E 226.55' THE GROVE PHASE 2, SECTION 3 PLAT BOOK P58, PAGE 5 50' PERIMETER BUFFERYARD 50' PERIMETER BUFFERYARD CLYDE D. LYNCH MARITAL TRUST - LOUISE GILLESPIE LYNCH 2 YEAR QUALIFIED PERSONAL RESIDENCE TRUST DEED BOOK 6624, PAGE 296 12'' W 12'' W 12'' W 12'' W 20' DRAINAGE EASEMENT 20' PUDE P2 P3 50' PERIMETER BUFFERYARD CLYDE D. LYNCH MARITAL TRUST - LOUISE GILLESPIE LYNCH 2 YEAR QUALIFIED PERSONAL RESIDENCE TRUST MAP 135, PARCEL 29 DEED BOOK 6624, PAGE 296 OPEN SPACE 4REVISED PLAT THE GROVE PHASE 1 SECTION 1 PLAT BOOK P88, PAGE 40 5195 5191 5187 5183 5179 5175 5201 EXISTING 8" FORCE MAIN 1-800-351-1111 E SSENNT EE E LA S L TSY C ONE M, . ICN!GI FEB POTS A -C LL RO E UOY D GRAPHIC SCALE 1" = 50' BEARINGS ARE RELATIVE TO THE TENNESSEE STATE PLANE COORDINATE SYSTEM NAD83 (CORS96) EPOCH 2002 Civil EngineeringLand Planning & ZoningLand Surveying 516 Heather PlaceNashville, TN 37204 (615) 297-5166 Dale & Associates D&A PROJECT #11053 SHEET: P3 SHEET 3 OF 3 N S WE 50050100 Prepared for: The Grove The Grove Section 18 Final Plat of Phase 2 and Phase 14 Preliminary Plat Located in the College Grove Community, and is the property of TVG Tennessee I, LLC, Book 5382, Page 78 and Book 6528, Page 732, Registers Office Williamson County, Tennessee 6437 Wildings Boulevard College Grove, Tennessee 37046 Revisions: R1 07/17/2026 ·Addressed Williamson County Comments posted on 07/13/2026, Project ID 2180481. 840 McCRORY CREEK Harpeth River Starnes Creek Eudailey- Covington Rd Covington Rd Eudailey- Arno Rd Arno-CollegeGrove Rd Bethesda Arno Rd Nathan Smith Rd Arno Rd Site Vicinity Map NTS Site N S WE CURVE TABLE CURVE DELTA ANGLE RADIUS ARC LENGTH CHORD BEARING CHORD LENGTH C12°52'30" 525.00'26.34'S 06°32'13" E26.34' C2 C3 C4 14°51'07" 475.00' 123.13'S 22°49'26" W122.78' C5 15°36'52" 475.00' 129.45'S 38°03'25" W129.05' C6 15°36'47" 475.00' 129.44'S 53°40'14" W129.04' C7 15°39'37" 475.00' 129.83'S 69°18'26" W129.42' 14°12'24" 475.00' 117.78'S 00°52'16" E117.48' 9°09'56" 475.00'75.98'S 10°48'55" W75.90' = 5/8" CAPPED IRON ROD (NEW) "DALE & ASSOCIATES" = 5/8" IRON ROD (OLD) "DALE & ASSOCIATES" *UNLESS OTHERWISE NOTED = FIRE HYDRANT = CURB INLET = WATER LINE = SIDEWALK W = HEADWALL = SEWER FORCE MAIN LINE = OVERHEAD UTILITY LINEOH FM = AREA DRAIN PUDE = PUBLIC UTILITY & DRAINAGE EASEMENT AREA TABLE Lot # Square Feet Acres 121,189 0.49 217,863 0.41 317,809 0.41 417,811 0.41 521,869 0.50 628,919 0.66 730,561 0.70 825,208 0.58 922,037 0.51 1022,614 0.52 1120,485 0.47 OPEN SPACE 1 18,107 0.42 OPEN SPACE 2 126,607 2.91 TOTAL 392,854 9.02 Percentage 4.61 % 32.23 % GENERAL NOTES: 1. THE PURPOSE OF THIS PLAT IS TO CREATE 11 LOTS AND 2 AREAS OF OPEN SPACE. 2. PROPERTY OWNER: THE GROVE PROPERTY OWNERS ASSOCIATION INC., DEED BOOK 5382, PAGE 78. 3. PROPERTY ADDRESS: 6437 WILDINGS BOULEVARD COLLEGE GROVE, TN. 4. PORTION OF WILLIAMSON COUNTY PARCEL 13.05 AS SHOWN ON MAP 142 AND ALL OF PARCEL 29.02, 29.08, 29.10 AS SHOWN ON 135. 5. BEARINGS SHOWN ARE BASED ON GPS OBSERVATION AND ARE RELATIVE TO THE TENNESSEE STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM 1983 (NAD83). 6. THIS SURVEY WAS PREPARED USING THE LATEST RECORDED DEEDS & PLAT DESCRIPTIONS REFERENCED HEREON. NO TITLE COMMITMENT WAS PROVIDED TO THIS SURVEYOR AT THE TIME OF SURVEY. THIS SURVEY IS SUBJECT TO SUCH FACTS THAT A CURRENT TITLE EXAMINATION MAY REVEAL. 7. ALL OPEN SPACE SHALL BE PUBLIC UTILITY, DRAINAGE, AND ACCESS EASEMENTS AND SHALL BE MAINTAINED BY THE PROPERTY OWNER(S) OR THE HOA. 8. MAINTENANCE OF ALL STORMWATER MANAGEMENT FEATURES, INCLUDING LOT LINE SWALES, SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S) OR THE HOA. 9. NO OBSTRUCTIONS OR ENCROACHMENTS WHICH IMPEDE THE FLOW OF STORMWATER SHALL BE PERMITTED WITHIN PUBLIC DRAINAGE EASEMENTS.    10. BASED ON MAP SCALING AND PLOTTING OF AVAILABLE FLOOD INSURANCE RATE MAPS AND/OR GIS DATA, THE SURVEYED PROPERTY IS LYING WITHIN ZONE X AS SHOWN: ·MAP NUMBER: 47187C0380G ·EFFECTIVE DATE: 12/20/2024 11. THIS PROPERTY HAS BEEN EVALUATED IN RELATION TO ARTICLE 13 OF THE WILLIAMSON COUNTY ZONING ORDINANCE FOR RESOURCE PROTECTION. THE RESOURCES INCLUDE, BUT ARE NOT LIMITED TO, SPECIAL FLOOD HAZARD AREA PROTECTION, WATERWAY PROTECTION, SLOPE AND SLIPPAGE SOILS PROTECTION, KARST FEATURES, HILLTOP AND RIDGETOP PROTECTION, WOODLAND AND TREE PROTECTION. HISTORICAL AND CULTURAL RESOURCES ARE NOT PRESENT ON THIS SITE. 12. WITHIN THE WATERWAY NATURAL AREA (WNA), THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED BY THE WILLIAMSON COUNTY ENGINEERING DEPARTMENT. 13. THIS PROPERTY HAS BEEN REVIEWED FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS (WNA) AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS HAVE BEEN LOCATED AS SHOWN. 14. THIS SURVEY MEETS THE REQUIREMENTS FOR A CATEGORY I SURVEY FOR URBAN AND SUBDIVISION PROPERTY AS PER CHAPTER 0820-03-05 OF STANDARDS OF PRACTICE AS ADOPTED BY THE BOARD OF EXAMINERS FOR LAND SURVEYORS FOR THE STATE OF TENNESSEE, HAVING A LINEAR ERROR OF CLOSURE NOT EXCEEDING 1 FT PER 10,000 FT OF PERIMETER OF LAND AND IS TRUE AND CORRECT. 15. NUMBERS SHOWN THUS XXXX ARE PROPERTY ADDRESSES. Map 142, Parcel 29.08 Map 142 Parcel 29.10 Book 5382, Page 78 and Map 135, Parcel 29.02 Book 6528, Page 732 Drawn By:NH Checked By: EC Scale: 1" = 50' Date: 06/01/2026 R1 07/20/2026 ATTACHMENT 22-1C ATTACHMENT 22-2 Item 23—Page 1 of 1 Reviewer: OCW Date: 8/13/2026 ITEM 23 FINAL PLAT REVIEW FOR DODD FAMILY REVOCABLE LIVING TRUST SUBDIVISION, CONTAINING 1 LOT ON 32.12 ACRES LOCATED OFF TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1 -2026-415). Attachment 23-1 Final Plat 23-2 Aerial Photograph Area 32.12 acres Zoning Rural Development-5 (RD-5) Lots 1 Water Nolensville/College Grove Utility District Sewer Individual On-Site Septic Systems Development Option Large Lot Easement Chapter 1101 Status Rural File Number (1-2026-415) A Preliminary Plat for this development was approved at the July 2026 Planning Commission Meeting. The applicant is now requesting approval of the Final Plat , consisting of one ( 1) Family Subdivision lot. A Variance to allow the shared drive to be less than the required sixteen (16) feet was granted at the July 2026 Planning Commission meeting. The Final Plat conforms with the approved Preliminary Plat, and Staff recommends approval with the following conditions: 1. The applicant shall adopt and record a covenant that declares that the access easement is not a public road, and imposes the requirement of maintenance by all properties served by the access easement. The covenant shall b e recorded concurrently with the recording of the plat; 2. The applicant shall submit a signed and notarized ‘Family Subdivision Affidavit and Restrictive Covenant,’ which shall be recorded concurrently with the recording of the plat. After the ‘Family Subdivision Affidavit and Restrictive Covenant’ has been recorded and prior to application for building permits, t he applicant shall provide a copy to the Planning Department application for Building Permits; and 3. Satisfaction of Section 3.05 of the Subdivisi on Regulations, as it pertains to fire apparatus access requirements for all lots, prior to building permit issuance. (14.00) DAVID M . DODD, ETUX DEED BOOK 9679, PAGE 382, R.O.W .C., TENNESSEE BARN BARN EXISTING RESIDENCE EXISTING RESIDENCE SHED (14.13) CARL ANTHONY FOSTER BOOK 9679, PAGE 359 R.O.W .C., TENNESSEE (14.12) R. O.W .C. , TENNESSEE (14.14)(14.14) DODD FAM ILY REVOCABLE LIVING TRUST DEED BOOK 9715, PAGE 252, R.O.W .C., TENNESSEE (14. 14) DODD FAM ILY REVOCABLE LIVING TRUST DEED BOOK 9715, PAGE 252, R.O.W .C., TENNESSEE (27) PATRICIA A. S HARP R EV. L IV. TRUST DEED BOOK 9808, PAGE 805, PLAT BOOK 14, PAGE 28, R.O.W .C., TENNESSEE EXISTING 50' INGRESS/EGRESS AND UTILITY EASEM ENT EXTENDS TO TALIAFERRO ROAD (14.06) M cCONLOGUE FAM ILY TRUST DEED BOOK 7497, PAGE 539, R.O.W .C., TENNESSEE N 82°39'18" W 698.47' N 10°48'29" E 135.56' LINE BEARING DISTANCE L1 S 77 °39'54 " W 39 .65' L2 S 83 °01'41 " E 32 .50' L3 N 06 °49 '10" E 20 .00' L4 S 83 °10'50 " E 30 .00' L5 N 83 °48 '16" W 36 .54' L6 S 82 °20'26 " E 53 .55' L8 N 79 °19 '33" W 33 .78' L9 N 09 °34 '07" E 56 .54' L10 S 13 °09'50 " W 38 .75' L11 N 82 °02 '24" W 10 .00' L12 S 77 °52'31 " E 5.00 ' C1 A3 A B C D E F G H DEED BO OK 921, PAGE 931, R.O.W .C., TN POND POND POND FLOW FLOW S 82°43'34" E 423.25' L8 L9 L10 (27. 05 ) DONALD W . ROLAND, ETUX DEED BOOK 408 2, PAGE 63 5, R.O.W .C., TENNESSEE LOT 6, PLAT BOOK 47 , PAGE 136 , R.O.W .C., TN. BARN 40' ELECTRIC TRANSM ISSION EASEM ENT 20' (14.13) SHED EXISTING RESIDENCE (14.06) M cCONLOGUE FAM ILY TRUST DEED BOOK 7497, PAGE 539, R.O.W .C., TENNESSEE 25' DRAINAGE EASEM ENT 25' DRAINAGE EASEM ENT 1399190 Sq. Feet 32.12 Acres REVISED DEED BO OK 10023, PAGE 543, R.O.W .C., TN EXISTING 50' INGRESS/EGRESS AND UTILITY EASEM ENT EXTENDS T O TALIAFERRO ROAD DEED BO OK 921, PAGE 931, R.O.W .C., TN DEED BO OK , PAGE , R.O.W .C., TN RE VISED AND EXTENDED N 79°49'38" W 355.10' N 82°39'43" W 220.48' N 10°49'22" E 440.60' N 82°38'41" W 230.18' N 07°52'37" E 700.00' N 82°43'34" W 248.69' S 07°35'21" W 303.03' S 07°54'23" W 192.80' S 07°54'23" W 230.11' S 06°49'10" W 105.95' S 83°01'50" E 149.97' S 06°49'10" W 106.15' S 10°40'27" W 162.63' S 12°59'15" W 1151.28' L1 L2 L3 L4 L5 C1 36.70' 44.81' 42.08' N 42°02'25" W 69°57'32" 1 S 12°07'29" W 183.81' N 83°07'08" W 155.78' N 07°57'36" E 202.49' (14.12) BARTON J. MAGOWAN, ETUX DEED BOOK 7075, PAGE 940, R.O.W.C., TENNESSEE L11 L12 50.00' 150.00 118.09' (14.07) DAVID DODD, ETUX DEED BOOK 9679, PAGE 392, R.O.W .C., TENNESSEE TURN AROUND AREA 298.82' 346.88' 122.97' 50.00' N 81°54'06" W 118.71' N 10°37'00" E 139.48' 100' M .B.S.L. 100' M .B. S.L. 100' M.B.S.L. 25' M.B.S.L. 100' M .B.S.L. 50' M .B.S.L. 25' M.B.S.L. 100' M .B.S.L. SITE CERTIFICATE OF OWNERSHIP AND DEDICATION I (we) hereby certify that I am (we are) the owner (s) of the property shown and described hereon, as evidenced in Deed Book 9715, Page 252, R.O.W.C., TN, and that I (we) adopt this plan of subdivision with my (our) free consent, establish the minimum building restriction line, and that offers of irrevocable dedicated for all public streets, utilities and other facilities have been filed as required by these Regulations. ______________________, 2026 _______________________________ DATE OWNER-DODD FAMILY REVOCABLE LIVING TRUST _______________________________ OWNER- CERTIFICATE OF ACCURACY I hereby certify that the plat shown and described hereon is true and correct survey to the accuracy required by the Williamson County, Tennessee Regional Planning Commission, and that the monuments have been or will be placed as shown hereon, to the specifications of the Subdivision Regulations, as approved by the County Engineer. ______________________, 2026 ________________________________ DATE REGISTERED LAND SUR VEYOR TN. REG. NO. 1434 CERTIFICATE OF GENERAL APPROV AL FOR INSTALLATION OF SUBSURFACE DISPOSAL SYSTEMS WITH RESTRICTIONS General approval is hereby granted for lots proposed hereon as being suitable for subsurface sewage disposal with the listed and/or attached restrictions. Before the initiation of construction, the location of the house or other structure and plans the for subsurface sewage disposal system shall be approved by the local health department. ______________________, 2026 ________________________________ DATE DEPT. OF SEWAGE DISPOSAL MANAGEMENT CERTIFICATE OF APPROV AL OF UTILITY SYSTEMS I hereby certify that the following utility systems outlined or indicated on the final plat subdivision entitled have been installed in accordance with current local and/or state government regulations or that a surety bond has been posted with the Planning Commission to assure the completion of all the required improvements in case of default. Also, I certify that the hydraulic design criteria specified in section 5.5 of the Williamson County Subdivision Regulations have been met. WATER SYSTEM_____________, 2026 __________________ __________________ NAME, TITLE, AND AGENCY OF AUTHORIZED APPROVING AGENT CERTIFICATE OF APPROV AL FOR RECORDING I hereby certify that the subdivision plat shown hereon has been found to comply with the Subdivision Regulations of Williamson County, Tennessee, with the exception of such variances, if any, as are noted in the minutes of the Planning Commission and it has been approved for recording in the office of the County Register. ______________________, 2026 ________________________________ DATE SECRETARY , PLANNING COMMISSION THIS APPROV AL SHALL BE INV ALID IF NOT RECORDED BY ____________________ Date PROPERTY MAP REFERENCE Being a portion of Parcel No.014.14 as shown on Williamson County Property Map No. 140 SPRING HILL, TN 37174 Fax: 615.523.1517 PH 615.481.3106 P.O. BOX 1636 Ahler & Associates, LLC w LEGEND OE GENERAL NOTES: 1. PLAN PR EPARED FOR: 2 . DEED REFERENCE: DEED BOOK 9715, PAGE 252. R.O.W.C., TN. 4. BEARINGS ARE BASED UPON T N STATE PLANE COODINATES 5. SUR VEY IS SUBJECT TO ALL THE FINDINGS AN ACCURATE TITLE SEARCH WOULD REVEAL. NO TITLE FURNISHED TO THIS SURVEYOR. 6. PHYSI CALLY EVIDENT UTILITIES ARE SHOWN BUT NOT WARRANTED. CONTRACTOR SHALL CONTACT 811, 72 HOURS PRIOR TO ANY EXCA V ATION AS PRESCRIBE BY STATE LAW. ON THE FEMA FIS RATE MAP NO. 471187C0385G DATED 12-20-2024 & 8. THIS PROPERTY IS SHOWN AS ZONE "X" 3. TAX MAP 140, PARCEL 014.14 DODD FAMILY REVOCABLE LIVING TRUST 8491 TALIAFERRO ROAD EAGLEVILLE, TN 37060 SCALE 1"=100' LOCATION MAP NTS SHEET 1 OF 2 MATCH LINE MATCH LINE EAGLEVILLE, WILLIAMSON CO., TN. 37060 8491 TALIAFERRO ROAD DODD FAMILY REVOCABLE LIVING TRUST FINAL PLAT 9. THIS PROPERTY IS ZONED RD-5 10. THE MINIMUM REQUIRED BUILDING SETBACKS: FRONT=100' SIDE=25', REAR=50'. 7. THIS IS A CATEGORY IV SURVEY AS DEFINED IN RUL 0820-03-.05 OF THE RULES OF THE TN BOARD OF EXAMINERS FOR LAND SURVEYORS. WE USED CARLSON BRx7 MULTI-FREQUECY GNSS UNITS. THIS IS A REAL TIME KINEMATICS (RTK) SURVEY WITH BASE-ROVER MODE UTILIZING 1983 EPOCH 2025.063 TN. STATE PLANE COORDINATES GEOID 2018 AND A COMBINED GRID TO GROUND SCALE FACTOR OF 1.0000123615. CONTROL W AS ESTABLISHED USING THE TDOT NETWORK AND NO FIXED STATIONS WERE USED. THE PURPOSE OF THIS PLAT IS TO OBTAIN APPROV AL FOR RELOCATION OF THE ACCESS EASEMENT ON PARCEL 14.14 TO ALLOW FOR APPROV AL OF A RESERVE SEPTIC FIELD PERC TEST TRACT 3 5355 SQ. FT 3-BDRM MAX 60 MPI MLPP 0-5% B A MINOR LARGE LOT SUBDIVISION PETTUS RD JUNE 15, 2026 SEPTIC TANK SWITCH V ALVE UNSUITABLE 471187C0395G DATED 12-20-2024 TYPICAL W OODEN FENCE 4' IN HEIGHT, W ITH THREE RAILS x x x FENCE ATTACHMENT 23-1A (14.00) DAVID M . DODD, ETUX DEED BOOK 9679, PAGE 382, R.O.W .C., TENNESSEE (14.13) CARL ANTHONY FOSTER BOOK 9679, PAGE 359 R.O.W .C., TENNESSEE (14.12) BA RTON J. M AGOW AN, ETUX DEED BO OK 7075, PAGE 940, R. O.W .C. , TENNESSEE (14.14) DODD FAM ILY REVOCABLE LIVING TRUST DEED BOOK 9715, PAGE 252, R.O.W .C., TENNESSEE BARN EXISTING RESIDENCE (14.13) CARL ANTHONY FOSTER BOOK 9679, PAGE 359 R.O.W .C., TENNESSEE (14.13) SHED EXISTING RESIDENCE 1399190 Sq. Feet 32.12 Acres 436671 Sq. Feet 10.02 Acres S 07°54'23" W 192.80' S 85°16'18" W 451.25' S 06°51'46" W 221.89' S 07°02'14" W 102.00' S 05°52'57" W 211.11' N 07°03'44" W 77.97' N 77°01'11" W 106.46' S 81°40'11" E 1 43.74' S 82°12'14" E 125.14' N 07°54'20" E 647.99' S 07°54'23" W 230.11' L6 C1 1 100' M .B.S.L. 100' M.B.S.L. 25' M.B.S.L. 50' M .B.S.L. SPRING HILL, TN 37174 Fax: 615.523.1517 PH 615.481.3106 P.O. BOX 1636 Ahler & Associates, LLC w LEGEND OE SCALE 1"=100' TALIAF ERRO ROAD 50' R. O.W . TALIAFERRO ROAD 50' R.O.W SHEET 2 OF 2 EAGLEVILLE, WILLIAMSON CO., TN. 37060 8491 TALIAFERRO ROAD DODD FAMILY REVOCABLE LIVING TRUST FINAL PLAT MATCH LINE MATCH LINE GENERAL NOTES: 1. PLAN PR EPARED FOR: 2 . DEED REFERENCE: DEED BOOK 9715, PAGE 252. R.O.W.C., TN. 4. BEARINGS ARE BASED UPON T N STATE PLANE COODINATES 5. SUR VEY IS SUBJECT TO ALL THE FINDINGS AN ACCURATE TITLE SEARCH WOULD REVEAL. NO TITLE FURNISHED TO THIS SURVEYOR. 6. PHYSI CALLY EVIDENT UTILITIES ARE SHOWN BUT NOT WARRANTED. CONTRACTOR SHALL CONTACT 811, 72 HOURS PRIOR TO ANY EXCA V ATION AS PRESCRIBE BY STATE LAW. ON THE FEMA FIS RATE MAP NO. 471187C0385G DATED 12-20-2024 & 8. THIS PROPERTY IS SHOWN AS ZONE "X" 3. TAX MAP 140, PARCEL 014.14 DODD FAMILY REVOCABLE LIVING TRUST 8491 TALIAFERRO ROAD EAGLEVILLE, TN 37060 9. THIS PROPERTY IS ZONED RD-5 10. THE MINIMUM REQUIRED BUILDING SETBACKS: FRONT=100' SIDE=25', REAR=50'. 7. THIS IS A CATEGORY IV SURVEY AS DEFINED IN RUL 0820-03-.05 OF THE RULES OF THE TN BOARD OF EXAMINERS FOR LAND SURVEYORS. WE USED CARLSON BRx7 MULTI-FREQUECY GNSS UNITS. THIS IS A REAL TIME KINEMATICS (RTK) SURVEY WITH BASE-ROVER MODE UTILIZING 1983 EPOCH 2025.063 TN. STATE PLANE COORDINATES GEOID 2018 AND A COMBINED GRID TO GROUND SCALE FACTOR OF 1.0000123615. CONTROL W AS ESTABLISHED USING THE TDOT NETWORK AND NO FIXED STATIONS WERE USED. THE PURPOSE OF THIS PLAT IS TO OBTAIN APPROV AL FOR RELOCATION OF THE ACCESS EASEMENT ON PARCEL 14.14 TO ALLOW FOR APPROV AL OF A RESERVE SEPTIC FIELD NOTE: THIS PROPERTY HAS BEEN REVIEWD FOR THE EXISTENCE OF INTERMITTENT AND PERENNIAL STREAMS. STREAMS THAT WOULD REQUIRE WATERWAY NATURAL AREAS AS DESCRIBED IN SECTION 4 OF THE WILLIAMSON COUNTY STORM WATER MANAGEMENT REGULATIONS HA VE BEEN LOCATED AS SHOWN. NOTE: THIS SITE HAS BEEN REVIEWED FOR THE PRESENCE OF STEEP SLOPES, HILLTOPS, AND RIDGETOPS, SLIPPAGE SOILS, AND KARST FEATURES. THERE ARE MODERATLY STEEP SLOPES WITHIN THE BUILDING ENVELOPE. NO WETLANDS ARE VISIBLE NOTE: THE EASEMENT FOR THE COMMON DRIVEW AY SHALL RUN WITH THE LAND AND SHALL BE BINDING ON AND SHALL INURE TO THE BENEFIT OF ALL PARTIES FOR WHOSE BENEFIT THE COMMON DRIVEWAY EXISTS, THEIR HEIRS, SUCCESSORS AND ASSIGNS. GEOTHERMAL WELL CONSTRUCTION STANDARDS FOR CLOSED LOOP GEOTHERMAN BOREHOLES SOURCE OF STRUCTURE M INIMUM DISTANCE SEWER LINES 10 FEET SEPTIC TANKS 25 FE ET SPRINGS 100 FEET SEPTIC DRAIN FIELDS 2 5 FEET WATER WELLS 100 FEET HOUSE TO SEPTIC CONNECTION 10 FEET HOUSE TO SEWER CONNECTION 10 FEET CURTAIN DRAIN TABLE A B C D E F G H GROUND ELEV. 785.3 792.4 794.0 794.0 795.0 793.6 792.0 785.6 I NVERT ELEV . 785.3 789.4 789.7 791.0 792.0 790.6 789.0 785.6 DRAIN DEPTH 0 3.0 4.3 3.0 3 3 3 0 MINOR LARGE LOT SUBDIVISION JUNE 15, 2026 471187C0395G DATED 12-20-2024 11. THERE WILL BE NO NEW ACCESS TO TALIAFERRO ROAD FROM PARCEL 14.14 12. E NGINEERED SITE PLANS ARE REQUIRED FOR BUILDING PERMIT APPLICATIONS IN MODERATELY STEEP SLOPE AREAS. 13. ANY NEW CONSTRUCTION WILL REQUIRE SPRINKLER SYSTEMS BE ADDED TO THE HOME. TYPICAL W OODEN FENCE 4' IN HEIGHT, W ITH THREE RAILS OR PRESENT AT THE TIME OF THE SURVEY . x x x FENCE PRIV ATE DRIVEWAY NOTATION PRIV ATE DRIVEWAY NOTATION This is a privae driveway and is not a public road. Williamson County does not have responsibility for building or maintaining the private driveway. The Williamson County Highway Commission may, at itsdiscretion, agree to accept this private driveway as a pub lic road and into thte County Highway System if allproperty owners agree to (1) petition the Highway Commission for a public road and (2) build or pay for upgrading the private driveway to County Specifications in effect at the time of the request. _____________________________, 20____ Date _____________________________________ ______________________________________ Connty Engineer County Road Superintendent By signing below, the property owner(s) of all lots within the bounds of this plat acknowledge awareness of the above Private Driveway Notation and understands Williamson County does not have responsibility for building or maintaining the private driveway.________________________________ _______________________________________ Owner Signature(s) Tax Map & Parcel number of Lot ______________________________ _____________________________ Date Deed Book & Page 14. A V ARIANCE ON DRIVEWAY WIDTH WAS APPROVED BY WILLIAMSON CO. PLANNING COMMISSION ON JUNE 11, 2026 ATTACHMENT 23-1B ATTACHMENT 23-2 MINUTES OF THE WILLIAMSON COUNTY REGIONAL PLANNING COMMISSION MEETING OF AUGUST 13, 2026 MEMBERS PRESENT Brian Clifford Don Crohan Lee Kennedy Steve Lane Jessica Lucyshyn Keith McCord Sammie McCoy STAFF PRESENT Michael Matteson, Community Development Director Aaron V. Holmes, Planning Director Floyd Heflin, County Engineer Michael Scott, Ass’t to County Engineer Kristi Ransom, County Attorney Joe James, Planning Coordinator Lincoln Sweet, Senior Planner Charlie Waldrop, Planning Technician Michelle Mullins, Planning Assistant The Williamson County Regional Planning Commission met in regular session Thursday, August 13, 2026, at 5:47 p.m. in the Auditorium of the Williamson County Administrative Complex. Commissioners Bailey, Baldree, Hatcher, Richter, and Sanders were unable to attend. Chairman McCoy called the meeting to order and took Roll Call. A quorum was present. Chairman McCoy asked if there were any announcements. Mr. Holmes announced the following: • Revised reports for Item 13 to correct a driveway reference, Item 15 reflecting open space requirements, and Items 16 and 18 where the applicant has requested deferral to the October meeting; • Item 9, Terravista, Section 2, Maintenance Bond for the Wastewater Collection System appeared on the Consent Agenda in the packets. However, Staff has removed it from the Consent Agenda for separate consideration; • Revised Consent Agendas reflecting removal of Item 9, and the deferral of Items 16 and 18 to the October meeting; • Items 12, 16, 17, 18, and 19 are on the Consent Agenda for Deferral ; • Additional Attachments 15 -3 and 15-4 have been added to the revised report for Item 15; and • Request for a Non-Agenda Item regarding consideration of request related to authority to approve Amendments to Hardeman Springs HOA documents. A Report was provided to Commissioners for review. Chairman McCoy asked for a motion to add the Non-Agenda Item requesting to approve Amendments to Hardeman Springs HOA documents to the Agenda. Commissioner Kennedy made a motion to add this Non-Agenda Item to the Agenda. The motion was seconded by Commissioner Lucyshyn. The motion was unanimously approved. Williamson County Planning Commission Meeting of August 13, 2026 Page 2 of 14 Chairman McCoy opened the floor to Public Comments. PUBLIC COMMENTS: Gerald Wigger, Counsel for the Terravista Homeowner’s Association (HOA), noted that at of the February 2026 Planning Commission Meeting, County Engineer, Floyd Heflin, stated that the rainy season was approaching and the Applicant’s Engineer felt that they could stabilize the Wastewater Road. Staff also stated that they would hold the Maintenance Bonds until the project had been completed as there had been multiple months to complete the issues, which included ponds that didn’t drain and Staff had advised there were multiple deviations from the approved plans. It was stated that if the project wasn’t completed by summer, that Staff would discuss calling the bonds. Mr. Wigger stated that there are major Roads, Drainage and Erosion Control (RDE) works in progress, but they are not near completion. There is significant damage to the common area, multiple broken concrete curbs, parking aprons, and fences, as well as the Stanley cul-de-sac is collecting all of the road deterioration runoff. We are at the end of the summer and the project is still nowhere near completion. He requests that per Mr. Heflin’s previous statement, the bonds be called. Chairman McCoy closed the Public Comments. C ONSIDERATION OF JULY 9, 2026 MINUTES: Chairman McCoy asked if there were comments or questions on the Minutes. Hearing none, he asked for a motion. Commissioner Crohan made a motion to approve the July 9, 2026 Minutes. The motion was seconded by Commissioner Clifford. The motion was unanimously approved. CONSENT AGENDA: Chairman McCoy mentioned that Item 9 was removed for separate discussion, and asked if there were any additional Items that needed to be discussed separately on the Consent Agenda. Hearing none, he asked for a motion to accept the Consent Agenda as a whole. Commissioner C rohan made a motion to approve the Consent Agenda per Staff recommendations. Commissioner Lane seconded the motion. The motion was unanimously approved. BONDS: 3. 1200 Old Hillsboro Road – Maintenance Bond for Landscaping located off Old Hillsboro Road. - $67,950 Recommendation: Extend in the current amount for a period of six (6) months. 4. King’s Chapel, Section 12 - Maintenance Bond for Wastewater Collection System located off Murfreesboro Road. - $21,000 Recommendation: Release the bond. 5. Lookaway Farms, Section 3 – Maintenance Bond for Wastewater Collection System located off Clovercroft Road. - $15,000 Recommendation: Release the bond. Williamson County Planning Commission Meeting of August 13, 2026 Page 3 of 14 6. Reeds Vale, Section 1 – Maintenance Bond for Wastewater Collection System located off Lampkins Bridge Road. - $96,600 Recommendation: Release the bond. 7. Starnes Creek, Section 2 – Maintenance Bond for Wastewater Collection System located off Meeks Road. - $12,900 Recommendation: Release the bond. 8. Starnes Creek Wastewater Area – Maintenance Bond for Wastewater Treatment and Disposal System located off Meeks Road. - $120,700 Recommendation: Release the bond. 9. Terravista, Section 2 - Maintenance Bond for Wastewater Collection System located off Long Lane. – NOT ON CONSENT 10. The Grove, Section 14 – Maintenance Bond or Roads, Drainage and Erosion Control located off Arno Road. - $425,000 Recommendation: Release the bond. DEFERRAL ITEMS: ITEM 12 PRELIMINARY PLAT REV IEW FOR LOFTY MEADOW ESTATES SUBDIVISION , CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GRO VE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 16 SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AND DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRE S LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007). At this time, the applicant is requesting deferral to the October 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. ITEM 17 SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG WRITER’S CABINS, ON 2.5 ACRES LOCATED OF F CLUB VIEW DRIVE IN THE 5TH VOTING DISTRICT (5-2026-006). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. Williamson County Planning Commission Meeting of August 13, 2026 Page 4 of 14 ITEM 18 CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON 108.16 ACRES LOCATED OFF HALEY LANE IN T HE 5TH VOTING DISTRICT (1 - 2026-203). At this time, the applicant is requesting deferral to the October 2026 Planning Commission Meeting in order to allow the appli cant more time to address Staff comments. Staff concurs with this request. ITEM 19 CONCEPT PLAN REVIEW FOR 1600 RIVER LANDI NG DRIVE SUBDIVISION , CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING D RIVE IN THE 9TH VOTING DISTRICT (1-2026-204). At this time, the applicant is requesting deferral to the September 2026 Planning Commission Meeting in order to allow the applicant more time to address Staff comments. Staff concurs with this request. FINAL PLATS: ITEM 22 FINAL PLAT REVIEW FO R THE GROVE SUBDIVISION, S ECTION 18, CONTAINING 11 LOTS ON 9.02 ACRES LOCATED OFF ARNO ROAD IN THE 2ND VOTING DISTRICT (1-2026-414). Final Plat is in order, and Staff recommends approval with the following conditions: 1. Establishment of a maintenance bond for water improvements in favor of Milcrofton Utility District in the amount of $44,332.30; 2. Per the recommendation of the County’s Wastewater Consultant, establishment of a performance bond for the wastewater collection system in the amount of $137,924.71; 3. Execution of performance agreements for the above referenced sureties; 4. The approved HOA documents must be recorded concurrently with the recording of the Final Plat; 5. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and 6. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. Williamson County Planning Commission Meeting of August 13, 2026 Page 5 of 14 ITEM 9 TERRAVISTA, SECTION 2 - MAINTENANCE BOND FOR WASTEWATER COLLECTION SYSTEM Mr. Holmes advised that the bond has satisfied the requisite two (2) year maintenance period. Therefore, Staff recommended releasing the bond. Chairman McCoy asked for confirmation that there are still other bonds for this project that are open. Mr. Holmes stated that was correct. Chairman McCoy asked if there were any questions on this Item. Commissioner Crohan asked if Staff was satisfied that the work had been completed sufficiently. Mr. Holmes advised that Staff is satisfied. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner Crohan made a motion to approve per Staff recommendation. Commissioner Clifford seconded the motion. The motion was unanimously approved. OLD BUSINESS: ITEM 23 ROADS, DRAINAGE AND EROSION CONTROL BOND REVIEW OF TERRAVIST A SUBDIVISION, SECTIONS 1 AND 2. Brent Thoeny, with TruLand Consultants, represented the applicant, The Jones Company. He advised that he had supplied the requested chart to the Commission, regarding the work timeline for the remaining items that are being worked on. He stated that since the July meeting, the gabion baskets have been added, but the pond bottoms are still trying to get them graded since it has been too wet due to the rain. To his understanding the County has reviewed the Site Plan for the mail kiosk. In Phase One (1) it is mainly all just the pond bottoms that they are working on and the access points where the workers are coming in and out will have to be resided once they have finished. I n Phase Two (2), pond five (5) is also holding some water in the flume and an area of water retention outside of the flume that is about fifteen (15) feet x fifteen (15) feet, which will need to be addressed. The storm drains will be videoed and anywhere that needs to be flushed , once the grade work is complete, will be done by a vendor that will be on standby. They are proposing to put a riprap up the wastewater road to try to stabilize that and the asphalt vendor cut the curve and should not have, so they will replace the curb. Chairman McCoy asked if the wastewater road has been paved. Mr. Theony confirmed that it had been paved, but that due to the amount of rain recently, the water is coming down the hill hitting the edge of the pavement causing it to wash down into the cul-de-sac. They are proposing a three (3) foot ditch running up the road on both sides with riprap and fabric to slow the water down . Chairman McCoy asked if the ditches will turn away from the road. Williamson County Planning Commission Meeting of August 13, 2026 Page 6 of 14 Mr. Theony stated they will continue to run into the road, because it is on a hillside, but they believe it is an issue of the speed of the water as opposed to the direction. Chairman McCoy asked if the cul-de-sac is being cleaned of the debris. Mr. Theony stated it had been cleaned. However, there was a little bit of debris that he has asked the workers to remove. Chairman McCoy asked if the cul-de-sac has been topped and finished. Mr. Theony confirmed that it has been topped. Chairman McCoy asked if there were any questions for Mr. Theony. Commissioner Clifford asked what their level of confidence was, so that they could assure the Commission that this project was a priority . Mr. Theony advised that for the last eight (8) weeks, barring the weather, they have been onsite working almost every day. Commissioner Clifford mentioned the pictures that had been submitted of the work that hadn’t been completed. He asked how confident Mr. Theony was that once Phase One (1) and Phase Two (2) had been completed, these types of issues were not going to continue to re-occur. Mr. Theony stated that in regard to the pictures, some of those pictures show how much it had recently rained, and that it currently looks as it did two (2) weeks ago, prior to the rain. He advised that he is fairly confident that there s houldn’t continue to be issues, unless there is consistent, heavy rainfall. Commissioner Clifford asked if Staff feels that the applicant is on track with the proposed timeline. Mr. Scott advised that he can’t say for sure when they will be finished, but that they are making progress, and the recent rains have made it difficult. They are trying to clean, re- stabilize, and re-grade. There is some erosion around the wastewater road that is being addressed as well. He believes they should continue working o n the project. Commissioner Lucyshyn stated that the schedule they provided shows a duration of a task, but when the task ends, it shows as ND, or “Not Done” on the schedule. She didn’t understand the value of showing the dates if the work was still not d one. Mr. Theony advised that below that it shows where it has been extended, because they are related to walks and checks. The only physical work out there at this point is the edges of the wastewater road, the bottom of the ponds and the storm pipe sewer video once the grading is done. He believes this should only take about two (2) weeks as long as there is no additional rainfall. Chairman McCoy made the comment that whatever work needs to be completed, should be done so in a way that there doesn’t continue to be issues that require long -term maintenance, and be left up to the Homeowner’s Association (HOA) to handle. Commissioner Crohan stated that he does not recall a project that has been this much of a problem while serving as a commissioner, and he feels that if this hasn’t been completed by the September meeting, the Commissioner should consider calling the bond and finding someone else to come in and finish the work . Williamson County Planning Commission Meeting of August 13, 2026 Page 7 of 14 Chairman McCoy asked if there were any further questions. Hearing none, he continued to the next Item. ITEM 12 PRELIMINARY PLAT REV IEW FOR LOFTY MEADOW ESTATES SUBDIVISION , CONTAINING 5 LOTS ON 32.3 ACRES LOCATED OFF ARNO -COLLEGE GRO VE ROAD IN THE 2ND VOTING DISTRICT (1-2025-310). This Item is on the Consent Agenda for Deferral. ITEM 13 PRELIMINARY PLAT REVIEW FOR LOT 1 OF THE LARRY U. TURNER PROPERTY LLE SUBDIVISION, CON TAINING 1 LOT ON 20. 33 ACRES LOCATED OFF TALIAFERRO ROAD IN THE 5TH VOTING DISTRICT (1-2026-301). Mr. Sweet reviewed the background (see Staff Report) recommending approval of this Preliminary Plat with the following conditions: 1. A Notice of Coverage issued by TDEC will be required prior to the issuance of a Land Disturbance Permit, if there is 1-acre or more of disturbance; 2. Prior to submittal of the Final Plat, provide a letter from the water provider either stating the water lines are installed and functioning or listing a Performance Bond amount for water improvements; 3. A Land Disturbance Permit must be obtained for the overall development; 4. Prior to submittal of the Final Plat, driveway and drainage infrastructure must be complete, consistent with County regulations; 5. Satisfaction of Section 3.05 of the Subdiv ision Regulations, as it pertains to fire sprinkler system requirements; and 6. Affixing a note to the Plat noting that all structures, including accessory structures, shall be separated by a minimum of 200 feet. Chairman McCoy asked if there were any questions. Commissioner Crohan advised that he understood Williamson County Fire and Rescue declined a variance for this, because they didn’t feel the driveway was capable of handling the equipment. He asked if their position had changed. Mr. Holmes stated that Staff had not received any documentation from Williamson County Fire and Rescue. Commissioner Crohan advised that he had documentation. Mr. Holmes confirmed that the document Mr. Crohan was referring to was provided by the applicant’s legal counsel, and it was a drafted copy that Staff did not receive for this particular Item. Commissioner Crohan advised that he would find it hard to approve a variance when there is as question as to whether fire equipment could acces s the property. Williamson County Planning Commission Meeting of August 13, 2026 Page 8 of 14 Chairman McCoy asked if the applicant was present. Doug Berry, with Miller Martin Law Firm represented the applicants, Mr. and Mrs. Russell, and he stated that he had provided a letter on this issue and would be happy to answer any questions. In response to Commissioner Crohan’s statement, there is an alternative for the variance, which is to have all structures on the property sprinkled with a separation distance of two hundred (200) feet between them all, and the applicant has agreed to do this. This is also a hardship to consider for one owner to financially cover the improvement of an entire easement that is also serving several other properties. To do this would additionally require the applicant to have to obtain easement rights from said property owners, not to mention that this was a situation the applicant moved into and did not create as the easement was created twenty-five (25) years ago, before subdivision jurisdiction applied to divisions of land . Therefore, they feel that the option to sprinkle the buildings and maintain the two hundred (200) foot distance should be adequate. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner McCord made a motion to approve per Staff recommendation. Commissioner Kennedy seconded the motion. Six (6) in favor, o ne (1) opposed , with Commissioner Crohan voting no. Motion passed. SITE PLANS: ITEM 14 SITE PLAN REVIEW FOR CREWS RUNWAY, ON 1, 137.13 ACRES LOCATED OFF BOY SCOUT ROAD IN THE 1ST VOTING DISTRICT (5 -2026-004). Mr. Holmes reviewed the background (see Staff Report) recommending approval of this Site Plan with the conditions that a Consolidation Deed and Land Disturbance Permit be obtained. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner Clifford made a motion to approve per Staff recommendation. Commissioner Lane seconded the motion. The motion was unanimously approved. ITEM 15 SITE PLAN REVIEW FOR WYELEA FARMS – THE STABLES, ON 53.70 AC RES LOCATED OFF DEL RIO PIKE IN THE 9TH VOTING DISTRICT (5 -2026-005). Mr. Waldrop reviewed the background (see Staff Report) recommending approval of this Site Plan with the following conditions: 1. Per the recommendation of the County’s Wastewater Consultant, the posting of a Performance Bond for the Collection System in the amount of $242,000; and 2. Final Plats of the areas to be transferred for both the Stables and Wyelea Farms Common Area, as depicted in Attachments 15- 3 and 15-4, shall be recorded before issuance of Building Permits for the Stables; and Williamson County Planning Commission Meeting of August 13, 2026 Page 9 of 14 3. Execution of a Performance Agreement for the above referenced sureties. Chairman McCoy asked if there were any questions. Hearing none, he asked for a motion. Commissioner Clifford made a motion to approve per Staff recommendation. Commissioner Kennedy seconded the motion. The motion was unanimously approved. ITEM 16 SITE PLAN REVIEW FOR NON-TRADITIONAL WASTEWATER TREATMENT AN D DISPOSAL SYSTEM REVI EW FOR BRYNN SUBDIVI SION, ON 108.12 ACRES LOCATED OFF HALEY LANE IN THE 5TH VOTING DISTRICT (5-2026-007). This Item is on the Consent Agenda for Deferral. ITEM 17 SITE PLAN REVIEW FOR TROUBADOUR GOLF AND FIELD CLUB – SONG WRITER’S CABINS, ON 2.5 ACRES LOCATED OF F CLUB VIEW DRIVE IN THE 5TH VOTING DISTRICT (5-2026-006). This Item is on the Consent Agenda for Deferral. CONCEPT PLANS: ITEM 18 CONCEPT PLAN REVIEW FOR BRYNN SUBDIVISION, CONTAINING 21 LOTS ON 108.16 ACRES LOCATED OFF HALEY LANE IN T HE 5TH VOTING DISTRICT (1 - 2026-203). This Item is on the Consent Agenda for Deferral. ITEM 19 CONCEPT PLAN REVIEW FOR 1600 RIVER LANDI NG DRIVE SUBDIVISION , CONTAINING 2 LOTS ON 22.76 ACRES LOCATED OFF RIVER LANDING D RIVE IN THE 9TH VOTING DISTRICT (1-2026-204). This Item is on the Consent Agenda for Deferral. Williamson County Planning Commission Meeting of August 13, 2026 Page 10 of 14 PRELIMINARY PLATS: ITEM 20 PRELIMINARY PLAT REV IEW FOR THE VILLAGES AT TRIUNE WEST SUBDIVISION (REVISED ), CONTAINING 98 SINGLE FAMILY LOTS, 214 TOWNHOME LOTS, AND T EN (10) NON-RESIDENTIAL LOTS ON 157.79 A CRES LOCATED OFF HORTON H IGHWAY IN THE 5TH VO TING DISTRICT (1 -2026- 309). Mr. James reviewed the background (see Staff Report) recommending approval of this Preliminary Plat with the following conditions: 1. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 55 th lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4 and 20-5) shall be completed to the satisfaction of the Tennessee Department of Transportation; 2. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 55th lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 20 -4 and 20 -5) shall be completed to the satisfaction of the Williamson County Highway Superintendent; 3. As specified by t he County’s Traffic Consultant, the i nstallation of traffic signals and construction of the right turn deceleration lanes on Horton Highway at the I- 840 Eastbound and Westbound Ramps shall be completed/constructed prior to the issuance of building permits for any of the non-residential land uses; 4. The residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane has been installed and is operational; 5. Prior to the submi ttal of the first Final Plat, the required Zoning Certificate for the wastewater treatment and disposal system shall be submitted, and all conditions associated with the wastewater site plan approval must be satisfied; 6. Prior to consideration of Final Plat approval, the applicant shall submit HOA documents for review and approval by the County Attorney’s office. The HOA documents must address the greenway easement, the maintenance and operation of the private roads and gate that meet the standards, and requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents must be submitted with the Final Plat, and the approved HOA documents must be recorded concurrently with the recording of the Final Plat; 7. A permit for the security gate will need to be obtained prior to its installation, and all requirements for such gates as outlined in Section 17.11 of the Zoning Ordinance must be met; 8. Prior to the submittal of any Final Plat in which a greenway is located, the 12 - foot-wide paved multi-modal greenway trail should be constructed; 9. Establishment of a performance bond for roads, drainage and erosion control; 10. Establishment of a performance bond for water improvements in favor of Nolensville/College Grove Utility District; 11. Establishment of a performance bond for the wastewater collection system; Williamson County Planning Commission Meeting of August 13, 2026 Page 11 of 14 12. Submission of landscaping plans and establishment of a performance bond for landscaping improvements; 13. Execution of Performance Agreements for the above -referenced sureties; 14. Execution of a Stormwater Maintenance Agre ement and submission of an Operation and Maintenance Plan for stormwater improvements; and 15. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane Coordinate System prior to signature and recording of the plat. Chairman McCoy asked if there were any questions. Commissioner Crohan asked why there is such a large change from the twenty -fifth (25th) to fifty-fourth (54th) lot before the traffic signal is put in. County Traffic Consultant, Kayla Ferguson advised that the applicant is going through the design process for the signal at Malachi Lane and Horton Highway, and that they may have had some difficulty with one of the property owners when obtaining easements. Therefore, their design approval from the Tennessee Department of Transportation (TDOT) took longer than expected. The signal is still on track to be completed by December, before any lots would be constructed. Chase Kerr, Crunk Engineering, represent ing the applicant, stated he could help explain the changes that are being made. He advised that this is also concurrent with Item 23, which is the East side. Though they are two (2) separate Items, combined they total eighty-four (84) lots. There was a lot of back and forth while trying to gain easement access between property owners at the intersection of Horton Highway and Malachi Lane, which caused a delay in the traffic signal design. They have obtained approval from TDOT, and the permit should be received by the following week, which is when they expect to start construction. The signal is expected to be installed before the end of the year and before any homes are under construction. This is to keep the project from being stalled. Commissioner Crohan asked for confirmation that they do feel the construction of the traffic signal would be complete by December, regardless of lot sales. Mr. Kerr advised that he did, and that there was also a long lead time on the traffic signal poles, because they are specially constructed. However, they do anticipate the intersection to be constructed and the traffic signals installed by December. Commissioner Crohan asked if it could be put into the Meeting Minutes that the traffic signal would be installed by the fif ty-fourth (54 th) lot or December, whichever comes first. Mr. Kerr stated that while he can’t predict the construction timeline, they do anticipate the signal being installed and operational by the end of the year. Commissioner Lucyshyn mentioned that the timeline is referring to when the Final Plat is submitted. She asked how many lots have been submitted in the Final Plat as of now. Mr. Kerr advised they have not submitted the Final Plat yet and they anticipate submitting it for September’s Meeting. Commissioner Lucyshyn asked Ms. Ferguson how they would follow th rough with there being no residential lots taking access to Malachi Lane until the traffic signal is installed. Williamson County Planning Commission Meeting of August 13, 2026 Page 12 of 14 Ms. Ferguson stated that she isn’t sure how access to roadways is governed by the County, but that they would be in the process of constructing both accesses, and therefore, she would assume that any of the internal roadway connections that would feed those lots would not be allowed to tie in. No traffic will be allowed until the signal is installed and active. Commissioner Lucyshyn asked if while this is happening, the only access to the site would be from Murfreesboro Road. Mr. Kerr confirmed that is correct. Chairman McCoy asked for confirmation that when a Final Plat is submitted, does that mean you have started building. Mr. Kerr advised that at that point they have not started building. Chairman McCoy asked if there were any further questions . Hearing none, he asked for a motion. Commissioner Clifford made a motion to approve per Staff recommendation. Commissioner Lane seconded the motion. The motion was unanimously approved. ITEM 21 PRELIMINARY PLAT REV IEW FOR THE VILLAGES AT TRIUNE EAST SUBDIVISION (REVISED ), CONTAINING 59 SINGLE FAMILY LOTS, 63 TOWNHOME LOTS, AND T HREE (3) NON-RESIDENTIAL LOTS ON 63.78 A CRES LOCATED OFF HORTON H IGHWAY IN THE 5TH VO TING DISTRICT (1 -2026- 310). Mr. James reviewed the background (see Staff Report) reco mmending approval of this Preliminary Plat with the following conditions: 1. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 31 st lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 21 -4 and 21-5) shall be completed to the satisfaction of the Tennessee Department of Transportation; 2. Except as noted in Number 3 below, prior to the submittal of the Final Plat containing the 31 st lot, all off-site roadway improvements associated with Phases 1 and 2 as specified by the County’s Traffic Consultant (See Attachments 21 -4 and 21 -5) shall be completed to the satisfaction of the Williamson County Highway Superintendent; 3. As specified by t he County’s Traffic Consultant, the i nstallation of traffic signals and construction of the right turn deceleration lanes on Horton Highway at the I- 840 Eastbound and Westbound Ramps shall be completed/constructed prior to the issuance of building permits for any of the non-residential land uses; 4. The residential lots shall not be permitted to take access to Malachi Lane until the traffic signal at the intersection of Horton Highway and Malachi Lane has been installed and is operational; 5. At eighty -five percent (85%) build -out, Malachi Lane shall be repaved in its entirety, as required by the Williamson County Highway Department; Williamson County Planning Commission Meeting of August 13, 2026 Page 13 of 14 6. Prior to the submittal of the first Final Plat, the required Zoning Certificate for the wastewater treatment and disposal syste m shall be submitted, and all conditions associated with the wastewater site plan approval must be satisfied; 7. Prior to consideration of Final Plat approval, the applicant shall submit HOA documents for review and approval by the County Attorney’s office. The HOA documents must address the greenway easement, the maintenance and operation of the private roads and gate that meet the standards, and requirements of Articles 16 and 17 of the Zoning Ordinance. The HOA documents must be submitted with the Final Pl at, and the approved HOA documents must be recorded concurrently with the recording of the Final Plat; 8. A permit for the security gate will need to be obtained prior to its installation, and all requirements for such gates as outlined in Section 17.11 of th e Zoning Ordinance must be met; 9. Prior to the submittal of any Final Plat in which a greenway is located, the 12 - foot-wide paved multi-modal greenway trail should be constructed; 10. Establishment of a performance bond for roads, drainage and erosion control; 11. Establishment of a performance bond for water improvements in favor of Nolensville/College Grove Utility District; 12. Establishment of a performance bond for the wastewater collection system; 13. Submission of landscaping plans and establishment of a performance b ond for landscaping improvements; 14. Execution of Performance Agreements for the above -referenced sureties; 15. Execution of a Stormwater Maintenance Agreement and submission of an Operation and Maintenance Plan for stormwater improvements; and 16. Submission of the approved Final Plat in .dwg format on recordable media based on the Tennessee State Plane

Text truncated. Open the original for the full document.

Source: Williamson County website. First collected Oct 18, 2026.