Board of Architectural Review Meeting — Agenda Packet
City of Charlottesville · Charlottesville City County · Board of Architectural Review · meeting of Nov 18, 2025 · Agenda packets
Open the original document More from City of Charlottesville
This document is no longer listed on City of Charlottesville's website. We kept the copy we read.
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
November 2025 BAR Packet 1
Packet Guide
City of Charlottesville
Board of Architectural Review
Regular Meeting
November 18, 2025 5:30 p.m.
Hybrid Meeting (In-person at Council Chamber and virtual via Zoom)
Pre-Meeting Discussion [NDS Conference Room, 5pm]
Regular Meeting [Council Chamber, 5:30pm]
A. Matters from the public not on the agenda
[or on the Consent Agenda]
B. Consent Agenda
[Note: The October 21, 2025 meeting minutes will be available for review at the next regular
meeting.]
1. Certificate of Appropriateness Application
BAR # HST25-0110
1314 Rugby Road, TMP 380092000
Individually Protected Property
Owner: Pete Snyder
Applicant: Jeff Dreyfus / Buschmann Dreyfus
Project: Replace pool pavilion
C. Deferred Items
2. Certificate of Appropriateness Application
BAR #
HST25-0112
159 Madison Lane, TMP 090145000
The Corner ADC District (contributing structure)
Owner: Montalto Corporation
Applicant: Paul Tassell / The Gaines Group
Project: Misc. repairs/improvements to south porch
D. New Items
N/A
E. Other Business
4. Staff Questions & Discussion
Update on workplan for review of design guidelines
New development review policy. Development Review Procedures Manual
F. Adjourn
November 2025 BAR Packet 2
Certificate of Appropriateness Application
BAR # HST25-0110
1314 Rugby Road, TMP 380092000
Individually Protected Property
Owner: Pete Snyder
Applicant: Jeff Dreyfus / Buschmann Dreyfus
Project: Replace pool pavilion
Application components (please click a bookmark below to go directly to the report pages):
• Staff Report
• Application Submittal
November 2025 BAR Packet 3
Certificate of Appropriateness Application
BAR # HST25-0112
159 Madison Lane, TMP 090145000
The Corner ADC District (contributing structure)
Owner: Montalto Corporation
Applicant: Paul Tassell / The Gaines Group
Project: Misc. repairs/improvements to south porch
Application components (please click a bookmark below to go directly to report pages):
• Staff Report
• Application Submittal
1314 Rugby Road Nov 20254 BAR (11/10) 1
City of Charlottesville
Board of Architectural Review
Staff Report
November 18, 2025
Certificate of Appropriateness Application
BAR # HST25-0110
1314 Rugby Road, TMP 380092000
Individually Protected Property
Owner: Pete Snyder
Applicant: Jeff Dreyfus / Buschmann Dreyfus
Project: Replace pool pavilion
Background
Year Built: House, 1910
District: Individually Protected Property
Status: Pergola : built after 1997, noncontributing
Four Acres. Colonial Revival house built in 1910. The pool, wall, and pool-side pergola at the
east side of the 3.9-acre parcel were constructed after 1997. The garage likely dates to the 1980s.
Prior BAR Reviews (See Appendix)
Application:
• Bushman Dreyfus Architects drawings Four Acres Pavilion – Permit Set, dated 9/8/2025:
Cover, sheet S1.1, S2.1, A1, and A2. 3D Views, sheet A2.1, undated. Select images from
2019 submittal for context.
Request CoA for construction of a poolside, open pavilion with standing-seam metal, gabled roof
supported by painted columns and lattice panels. The pavilion will be constructed within the
footprint of an existing pergola, to be removed.
Discussion and Recommendation
Staff recommends approval as submitted. The existing pergola is not historic. The pavilion
design not out of character with the historic house, and is consistent with the adjacent garage, the
most prominent nearby structure.
1314 Rugby Road Nov 20254 BAR (11/10) 2
Existing
Proposed
Suggested Motions
Approval (with approval of the Consent Agenda): Having considered the standards set forth
within the City Code, including the ADC District Design Guidelines, I move to find the proposed
pavilion at 1314 Rugby Road satisfies the BAR’s criteria and is compatible with this IPP, and
that the BAR approves the application as submitted.
Criteria and Guidelines
Note re: BAR authority: Per Code, the BAR is charged only with the authority to approve or
deny a design review CoA, following an evaluation applying the criteria under Code Sec. 34-
5.2.7. Major Historic Review. The BAR does not evaluate a proposed use. Additionally, per
Code Sec. 34-5.2.7.E.2., the issuance of a CoA “cannot, in and of itself, authorize any
construction, reconstruction, alteration, repair, demolition, or other improvements or activities
1314 Rugby Road Nov 20254 BAR (11/10) 3
requiring a building permit. Where a building permit is required, no activity authorized by a
[CoA] is lawful unless conducted in accordance with the required building permit and all
applicable building code requirements.”
Review Criteria Generally
Per Chapter 34, Div. 5.2.7. C.2:
a. In considering a particular application the BAR will approve the application unless it finds:
i. That the proposal does not meet specific standards set forth within this Section or
applicable provisions of the City’s design guidelines; and
ii. ii. The proposal is incompatible with the historic, cultural or architectural character of the
district in which the property is located or the IPP that is the subject of the application.
b. The BAR will approve, approve with conditions, or deny applications for Certificates of
Appropriateness in accordance with the provisions of this Section.
c. The BAR, or City Council on appeal, may require conditions of approval as are necessary or
desirable to ensure that any new construction or addition is compatible with the scale and
character of the Architecture Design Control District, Individually Protected Property, or
Historic Conservation District. Prior to attaching conditions to an approval, due consideration
will be given to the cost of compliance with the proposed conditions as well as the goals of
the Comprehensive Plan. Conditions may require a reduction in height or massing, consistent
with the City’s design guidelines and subject to the following limitations [not germane]:
Standards for Review and Decision
Per Chapter 34, Div. 5.2.7. D.1:
a. Review of the proposed construction, reconstruction, alteration or restoration of a building or
structure is limited to exterior architectural features, including signs, and the following
features and factors:
i. Whether the material, texture, color, height, scale, mass, and placement of the
proposed addition, modification or construction are visually and architecturally
compatible with the site and the applicable District;
ii. The harmony of the proposed change in terms of overall proportion and the size and
placement of entrances, windows, awnings, exterior stairs, and signs;
iii. The Secretary of the Interior Standards for Rehabilitation set forth within the Code of
Federal Regulations (36 C.F.R. §67.7(b)), as may be relevant;
iv. The effect of the proposed change on the adjacent building or structures;
v. The impact of the proposed change on other protected features on the property, such
as gardens, landscaping, fences, walls, and walks;
vi. Whether the proposed method of construction, renovation, or restoration could have
an adverse impact on the structure or site, or adjacent buildings or structures;
vii. When reviewing any proposed sign as part of an application under consideration, the
standards set forth within Div. 4.11. Signs will be applied; and
viii. Any applicable provisions of the City’s design guidelines.
Links to ADC District Design Guidelines
Chapter 2 Site Design and Elements
From Chapter 2 – Site Design and Elements
G. Garages, Sheds, and Other Structures: A number of houses in Charlottesville’s historic
districts have garages, outbuildings and distinctive site features, particularly properties that
contain a large house on a large lot. The most common outbuilding is the garage. Site features
1314 Rugby Road Nov 20254 BAR (11/10) 4
may vary considerably and may include fountains, ponds, pools, trellises, pergolas or benches, as
well as recreational spaces such as playsets or basketball courts.
1) Retain existing historic garages, outbuildings, and site features in their original locations.
2) If it is acceptable to relocate a secondary structure, locate it in such a way that it remains
consistent with the general pattern of outbuildings to the main structure. (See Chapter 7 C.
Moving Historic Structures.)
3) Choose designs for new outbuildings that are compatible with the major buildings on the site.
4) Take clues and scale from older outbuildings in the area.
5) Use traditional roof slopes and traditional materials.
6) Place new outbuildings behind the dwelling.
7) If the design complements the main building however, it can be visible from primary
elevations or streets.
8) The design and location of any new site features should relate to the existing character of the
property.
Appendix
Prior BAR Reviews
February 24, 1998 – BAR approved CoA for addition to the west and rear. The property
changed hands before the design was executed.
June 15, 1999 – BAR approved CoA for a rear addition, with condition that no stucco be applied
to the front block of the house.
July 20, 1999 – BAR denied CoA to apply stucco to the base of the front of the house.
November 29, 1999 – Administrative approval 7 ft. high cedar fence along side property lines
and 4 ft. high vinyl-clad cyclone fence along rear property line.
January 19, 2020 – BAR approved CoA for screened porch addition to the east end of the
building.
April 9, 2019 – Administrative approval for minor alterations to non-contributing garage and
misc. paving at driveway and pool. All c1997 work at east side of property.
EXISTING MAIN HOUSE TO
REMAIN
EXISTING POOL HOUSE
TO REMAIN
SCOPE OF WORK:
EXISTING PERGOLA TO
BE RENOVATED.
NOTE: INFORMATION ON THIS PLAN INCLUDING
BUILDING OUTLINES AND PROPERTY LINE IS SOURCED
FROM GIS AND SATELLITE IMAGERY AND MAY NOT
ACCURATELY REFLECT CONDITIONS ON SITE
PRO
PERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
SCALE: 1/64" = 1'-0"
ISSUE ID
01
ISSUE NAME
PERMIT SET
DATE
09.08.2025
S1.1
S2.1
A1
A2
COVER SHEET
FRAMING AND FOUNDATION PLANS
FRAMING AND FOUNDATION DETAILS
PLANS
ELEVATIONS & SECTIONS09.08.2025
PERMIT SET
FOUR ACRES PAVILION
1314 RUGBY ROAD, CHARLOTTESVILLE, VA 22903
DESIGN TEAM EDITION
EDITION AND REVISION HISTORY
OWNER
PETE & BURSON SNYDER
1314 RUGBY ROAD, CHARLOTTESVILLE, VA 22903
ARCHITECT
BUSHMAN DREYFUS ARCHITECTS PC
820 EAST HIGH STREET SUITE B
CHARLOTTESVILLE, VA 22902
434.295.1936
KIRK WEBB
KWEBB@BDARCHITECTS.COM
CONTRACTOR
ALEXANDER NICHOLSON
100 KEYSTONE PLACE, CHARLOTTESVILLE VA
434.296.7526
STRUCTURAL ENGINEER
DUNBAR
110 THIRD STREET, CHARLOTTESVILLE VA
434.293.5171
DATE OF ISSUEPROJECT INFORMATION
PROJECT ADDRESS
1314 RUGBY ROAD, CHARLOTTESVILLE, VA 22903
SHEET INDEX
REFERENCE BUILDING CODES
IRC 2021 VIRGINIA RESIDENTIAL CODE
IECC 2021 VIRGINIA ENERGY CONSERVATION CODE
NFPA-101 2021 VIRGINIA LIFE SAFETY CODE
GENERAL
1. BUILD TO DIMENSIONS NOTED. DO NOT SCALE FROM DRAWINGS.
2. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS.
3. REPORT IMMEDIATELY TO THE ARCHITECT ANY DISCREPANCIES IN NOTES OR DIMENSIONS.
4. DIMENSIONS ARE TO FACE OF FRAMING UNLESS OTHERWISE NOTED.
5. ALL MASONRY DIMENSIONS ARE NOMINAL.
SCOPE
WORK INCLUDED UNDER THIS CONTRACT INCLUDES THE RENOVATION OF AN EXISTING POOLSIDE
PAVILION STRUCTURE AND ASSOCIATED SITE WORK AS DEPICTED IN THIS DRAWING SET.
INCLUDE ALL MATERIALS, LABOR AND EQUIPMENT FOR A COMPLETE PROJECT. ANY ADDITIONAL
LANDSCAPING IS OUTSIDE OF THIS CONTRACT.
COORDINATION
ACCURATE EXECUTION OF THE WORK MAY INVOLVE COORDINATING INFORMATION DEPICTED ON
SEVERAL DRAWINGS. CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE FAMILIAR WITH THE
ENTIRE SET OF DRAWINGS WHEN WORKING. (FOR EXAMPLE, CORRECT PLACEMENT OF ELECTRICAL
FIXTURES AND PLUMBING FIXTURES MAY REQUIRE AN UNDERSTANDING OF THE FRAMING LAYOUT,
OR THE FINISHES BEING USED).
SITE
PROTECT SIGNIFICANT TREES TO REMAIN WITHIN CONSTRUCTION AREA, VERIFY ANY TREES TO BE
REMOVED WITH THE ARCHITECT PRIOR TO ANY CLEARING WORK.
PROVIDE A SAFE CONSTRUCTION SITE FREE OF UNDUE HAZARDS.
SMOKING
CONTRACTOR SHALL ENSURE THAT NO SMOKING TAKES PLACE ANYWHERE ON THE PROPERTY
EXCEPT AT A SMOKING AREA SO DESIGNATED BY THE CONTRACTOR.
ALL ASSOCIATED REFUSE SHALL BE COLLECTED AND REMOVED AT THE END OF EACH DAY.
BIMc loud: bdar chitects - BIMc loud Sof tware as a Service/ 4 Acres Pool/ Four Acres Pool Monda y , Se pte mbe r 8, 20 25 5:54 P M
SITE PLAN
61
A
D
432 5
B
C
HSS
6X6X1
/4
HSS
6X6X1
/4
6X6 TIM
BE
R
6X6 TIM
BE
R
HSS
4X4X1
/4
HSS
4X4X1
/4
HSS
4X4X1
/4
HSS
4X4X1
/4
6X6 TIM
BE
R
6X6 TIM
BE
R
HSS
6X6X1
/4
HSS
6X6X1
/4
S2.1
6
EXISTING SLAB ON
GRADE TO REMAIN
S2.1
8
S2.1
7
A
S1.1
EXISTING BRICK
WALL TO REMAIN
NEW FOOTING -
SEE DETAILS
61
A
S2.1
2
D
432 5
(3) 1 3/4 X 11 7/8 LVL
B
C
(3) 1 3/4 X 11 7/8 LVL
(3) 1 3/4 X 11 7/8 LVL (3) 1 3/4 X 11 7/8 LVL
(3) 1 3/4 X 11 7/8 LVL
S2.1
3
(3) 1 3/4 X 11 7/8 LVL(3) 1 3/4 X 11 7/8 LVL
4X104X10
4X104X10
4X104X10
4X104X10
4X124X12 4X12
TIE ROD
TIE ROD
TIE ROD
TIE ROD
RIDGE
8X10 8X108X8 (BOTTOM
CHORD)
8X10 8X108x88X8 (BOTTOM
CHORD)
S2.1
4
S2.1
1
S2.1
2
S2.1
5
4X104X10
4X104X10
DL-1: LIVE LOADS (REFER TO FRAMING PLANS FOR MORE SPECIFIC LOADS)
ROOF 20 PSF
DL-2: SNOW LOADS
Pg=34 PSF (GROUND SNOW - ASD)
Ce=1.0 (SNOW EXPOSURE FACTOR)
Ct=1.0 (THERMAL FACTOR)
Pf (SNOW LOAD FOR LOW-SLOPE ROOF)=0.7X(Ce)X(Ct)X(Is)X(Pg) = 0.7X1.0X1.0X1.0X34 = 24 PSF
USE 25 PSF MIN
DL-3: WIND LOADS
V=115 MPH (BASIC WIND SPEED: 3-SECOND GUST)
EXPOSURE C
Kd=0.85 (WIND DIRECTIONALITY FACTOR)
Kzt=1.0 (TOPOGRAPHIC FACTOR)
Ke=1.0 (GROUND ELEVATION FACTOR)
DL-4: CONCENTRATED LOADS (OVER 2.5'X2.5' AREA):
300 POUNDS - ROOFS
DESIGN LOADS AND PARAMETERS
EC-1: FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO THE CONSTRUCTION AND FABRICATION
OF ANY NEW STRUCTURAL MEMBERS.
EXISTING CONSTRUCTION
F-1: FOUNDATIONS FOR THIS STRUCTURE ARE SPREAD FOOTINGS BEARING ON EITHER VIRGIN SOIL OR
CONTROLLED COMPACTED FILL WITH AN ASSUMED SOIL BEARING CAPACITY OF 2000 PSF.
F-2: THE OWNER'S GEOTECHNICAL ENGINEER SHALL VERIFY, PRIOR TO POURING CONCRETE, THAT THE SOIL IS
CAPABLE OF SUPPORTING SUCH A LOAD AND IS CONSISTENT WITH THE GEOTECHNICAL REPORT.
F-3: THE CONTRACTOR SHALL PROTECT THE FOOTINGS AND SLABS FROM DAMAGE FROM FROST HEAVE DURING
CONSTRUCTION UNTIL THE FINAL DESIGN STRUCTURE IS COMPLETE.
F-4: BACKFILL AGAINST WALLS SPANNING VERTICALLY BETWEEN FLOORS SHALL NOT BE PLACED UNTIL BOTH
FLOORS ARE IN PLACE AND CONCRETE HAS REACHED 75% OF ITS 28-DAY STRENGTH.
SS-1: ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF AISC 360-16 "SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS". BOLTED CONNECTIONS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION
UNLESS NOTED OTHERWISE ON PLAN. REFER TO DRAWINGS FOR CONNECTIONS. IF CONNECTIONS ARE NOT
SHOWN, FABRICATOR SHALL DESIGN CONNECTIONS FOR BEAM UNIFORMLY LOADED TO CAPACITY.
• ASTM A500 GRADE C (SQUARE AND RECTANGULAR HSS SHAPES) Fy = 50 KSI
• ASTM A572 GRADE 50 (PLATE AND BAR) Fy = 50 KSI
• ASTM A36 (ANGLE, CHANNELS, AND OTHER STRUCTURAL SHAPES) Fy = 36 KSI
• E70XX (SMAW PROCESS WELDING)
• ASTM F1554 Fy=36 KSI (ANCHOR RODS UNO)
SS-2: ALL STEEL MEMBERS AND CONNECTORS EXPOSED TO THE WEATHER SHALL BE HOT-DIP GALVANIZED
C-1: ALL CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-10 "SPECIFICATIONS FOR
STRUCTURAL CONCRETE" AND ACI 318-14 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE".
• f'c=3500 PSI (SLABS-ON-GRADE )
• f'c=3000 PSI (ALL OTHER CONCRETE)
• ASTM A615 GRADE 60 (TYPICAL REINFORCING STEEL)
• ASTM A706 (REINFORCING STEEL AT WELDED CONDITIONS)
• ASTM A1064 (PLAIN WELDED WIRE FABRIC - USE FLAT SHEETS ONLY)
C-2: ALL EXTERIOR EXPOSED CONCRETE SHALL BE FURNISHED WITH AN AIR-ENTRAINING ADMIXTURE PROVIDING
AN AIR-CONTENT OF 6% (+/- 1 1/2%) AT POINT OF PLACEMENT - REFER TO SPECIFICATIONS.
FOUNDATIONS
STRUCTURAL STEEL
RC-1: ALL ROUGH CARPENTRY SHALL CONFORM TO THE REQUIREMENTS OF THE NDS-2018
"NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION WITH 2018 SUPPLEMENT".
RC-2: PROVIDE NO. 2 SOUTHERN PINE WITH 19% MAXIMUM MOISTURE CONTENT FOR ALL FRAMING LUMBER
INCLUDING, LINTELS, JOISTS, RAFTERS, AND BEAMS UNLESS NOTED OTHERWISE. WALL STUDS AND PLATES
MAY BE S-P-F No. 1 / 2 UNO ON PROJECT SPECIFIC DETAILS AND NOTES.
RC-3: PROVIDE WOOD I-JOIST, MICROLLAM VENEER LUMBER (LVL), PARALLAM PARALLEL STRAND LUMBER (PSL),
AND TIMBERSTRAND LUMBER (LSL) MANUFACTURED BY TRUS JOIST (OR APPROVED EQUAL).
RC-4: ALL FRAMING CONNECTIONS NOT SPECIFICALLY INDICATED ON THESE CONSTRUCTION DOCUMENTS
SHALL COMPLY WITH THE MINIMUMS ESTABLISHED BY TABLE 2304.10.1 OF THE VUSBC.
RC-5: ALL NAILED CONNECTIONS (OF TWO 2x MEMBERS) SPECIFICALLY INDICATED ON THESE CONSTRUCTION
DOCUMENTS ARE ASSUMED TO BE DONE USING A MINIMUM NAIL SIZE OF 0.131" DIAMETER x 3" LONG UNLESS
NOTED OTHERWISE.
RC-6: PROVIDE A MINIMUM OF THREE INCHES OF BEARING FOR ENGINEERED LUMBER BEAMS, UNLESS
OTHERWISE NOTED.
RC-7: ALL BEAMS SHALL BE LATERALLY SUPPORTED BY BLOCKING OR OTHER MEANS AT ALL POINTS OF
BEARING.
RC-8: NAILS INSTALLED PARALLEL TO THE GLUE LINES ON THE NARROW FACE OF ENGINEERED LUMBER BEAMS
SHALL NOT BE SPACED CLOSER THAN FOUR INCHES FOR 10d COMMON NAILS AND THREE INCHES FOR 8d
COMMON NAILS.
RC-9: DO NOT DRILL, NOTCH, CUT (EXCEPT TO LENGTH), OR ALTER ENGINEERED LUMBER BEAMS OR JOISTS
WITHOUT WRITTEN APPROVAL OF FABRICATOR AND REVIEW BY STRUCTURAL ENGINEER.
ROUGH CARPENTRY
PA-1: ALL POST-INSTALLED ANCHORS (IN CONCRETE OR CMU) ARE TO BE INSTALLED IN STRICT CONFORMANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS (INCLUDING BUT NOT LIMITED TO DRILL BIT SIZE, PROPER
CLEANING OF HOLES, INSTALLATION TORQUE, AND TEMPERATURE CONSTRAINTS).
PA-2: WHEN A SPECIFIC PRODUCT AND MANUFACTURER IS REFERENCED IN THE CONTRACT DOCUMENTS, THAT
SPECIFIC PRODUCT SHALL BE USED UNLESS AN ALTERNATE PRODUCT IS APPROVED IN WRITING BY THE
STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CODE COMPLIANT STRENGTH
DESIGN CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE
PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN
ICC - ES REPORT SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD
RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS.
ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION
TEMPERATURE.
PA-3: FASTENERS REFERRED TO AS "SCREW ANCHOR" ON THE DRAWINGS SHALL BE ONE OF:
• TITEN HD BY SIMPSON STRONG-TIE
• KWIK HUS-EZ (KH-EZ) BY HILTI
• SCREW-BOLT+ BY DEWALT
FOR THESE SCREW ANCHORS LISTED, USE STANDARD ANSI DRILL BIT (NO SPECIAL BIT REQUIRED). PROVIDE
HOLES IN STEEL MEMBERS 1/8" LARGER THAN NOMINAL DIAMETER OF ANCHOR. PROVIDE STD ZINC-PLATED
CARBON STEEL ANCHOR UNLESS MECHANICAL GALVANIZED FINISH OR STAINLESS STEEL ANCHOR IS INDICATED
ON DRAWINGS.
PA-4: CHEMICAL ADHESIVE ANCHORING SYSTEMS USED IN HOLLOW MASONRY GENERICALLY REFERRED TO AS
ADHESIVE ANCHORING SYSTEMS SHALL BE ONE OF:
• HIT-HY 270 BY HILTI
• SET XP SYSTEM BY SIMPSON STRONG-TIE
• AC100+ GOLD BY DEWALT
USE SCREEN TUBES BY THE SAME MANUFACTURER WHEN USING THESE ADHESIVES IN MASONRY WITH VOIDS OR
HOLLOW CMU. INSTALL USING DRILL IN ROTATION-ONLY MODE TO KEEP FROM DAMAGING INSIDE OF FACE SHELL.
PA-5: CHEMICAL ADHESIVE ANCHORING SYSTEMS USED IN SOLID OR GROUTED MASONRY GENERICALLY
REFERRED TO AS ADHESIVE ANCHORING SYSTEMS SHALL BE ONE OF:
1. SET XP BY SIMPSON STRONG TIE
2. HIT-HY 270 BY HILTI
3. AC100+ GOLD BY DEWALT
PA-6: CHEMICAL ADHESIVE ANCHORING SYSTEMS USED IN CONCRETE GENERICALLY REFERRED TO AS "ADHESIVE
ANCHORS" SHALL BE ONE OF :
• SET - 3G BY SIMPSON STRONG-TIE
• HIT-RE 500-V3 BY HILTI
• HIT-HY 200 BY HILTI
• PURE 110+ BY DEWALT
• AC 200+ BY DEWALT
THREADED ROD ANCHORS USED WITH THESE SYSTEMS SHALL BE PROVIDED BY THE ADHESIVE MANUFACTURER
AND HAVE A MINIMUM STEEL STRENGTH OF Fy = 36 KSI UNLESS NOTED OTHERWISE.
PA-7: CHEMICAL ADHESIVE ANCHOR SYSTEMS FOR USE WITH REINF STEEL IN CONCRETE SHALL BE ONE OF:
• SET-3G BY SIMPSON STRONG-TIE
• HIT-RE 500-V3 BY HILTI
• HIT-HY 200 BY HILTI
UNLESS NOTED OTHERWISE, REINFORCING STEEL USED WITH THESE SYSTEMS SHALL BE ASTM A615 GRADE 60.
PA-8: FASTENERS GENERICALLY REFERRED TO AS "CONCRETE/MASONRY SCREWS" SHALL BE ONE OF:
1. TITEN TURBO BY SIMPSON STRONG-TIE
2. KWIK-CON II+ BY HILTI
3. TAPPER+ BY DEWALT
PA-9: FASTENERS GENERICALLY REFERRED TO AS "PAF" (POWER ACTUATED FASTENERS) SHALL BE ONE OF :
PAF INTO CONCRETE OR STRUCTURAL STEEL:
ANCHOR MANUF SHANK DIAMETER
1. X-U HILTI 0.157"
2. 8 mm HEAD SPIRAL CSI PIN DEWALT FASTENERS 0.157"
3. PDPA SIMPSON 0.157"
USE ONLY HILTI X-U PAF IN STRUCTURAL STEEL GREATER THAN 1/2" THICK. 1/2" MINIMUM POINT PENETRATION IS
REQUIRED IN STRUCTURAL STEEL GREATER THAN 1/2" THICK.
PROVIDE MINIMUM 1 1/4" EMBEDMENT OF PAF INTO CONCRETE.
POST-INSTALLED ANCHORS
CONCRETE
GBC-1: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2021 VIRGINIA RESIDENTIAL CODE. WALL
BRACING DESIGN SHOWN ON THIS DRAWING IS AN ENGINEERED DESIGN IN ACCORDANCE WITH SECTION R301.1.3
AND THE INTERNATIONAL BUILDING CODE (IBC).
GBC-2: NO LOADS IN EXCESS OF THE DESIGN LIVE LOADS LISTED SHALL BE IMPOSED UPON ANY AREA DURING
CONSTRUCTION, UNLESS ADEQUATE SHORING OR OTHER MEANS IS PROVIDED TO SUPPORT THE EXCESSIVE
LOADS.
GCB-3: THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY
COMPLETED. THE ERECTION PROCEDURE AND SEQUENCE INCLUDING THE DESIGN ADEQUACY AND SAFETY OF
ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
GCB-4: REFER TO ARCHITECTURAL DRAWINGS FOR WATERPROOFING DETAILS.
GENERAL/BUILDING CODE
D
3
L3X3X1/4 X 0'-4" WITH
1/2" DIA X 4" EMBED
ADHESIVE ANCHOR
EACH SIDE AT 24'' OC
3/16
NEW HSS COLUMN
EXISTING BRICK WALL
TO REMAIN
1/4" = 1'-0"
FOUNDATION PLAN
S1.1
FRAMING AND
FOUNDATION
PLANS
1/4" = 1'-0"
ROOF FRAMING PLAN
S1.1 S1.13/4" = 1'-0"
APLAN DETAIL
RAFTER BEARING
10' - 5 1/4"
1 2
ROOF DECK
8X8 CONT
BOTTOM CHORD
AT GABLE ENDS
LVL BEYOND
SIMPSON A35 AT 16"
(8X8 TO LVL)
RAFTER BEARING
10' - 5 1/4"
A B
1'-7"
2" 2"
1 1/2" 3" 3"
U-SHAPED STEEL CONNECTION COMPRISED
OF (2) 1/4 X 4 X 1'-1" PLATES AND (1) 1/2 X 4
X 0'-3 5/8" PLATE. SHOP WELD WITH 1/4"
FILLET ALL-AROUND
1'-1"
3/4" A36 TIE RODS AND
TURNBUCKLE
1/2" LAG SCREW IN PRE-BORED
HOLE WITH 3 1/2" EMBED
1" T&G ROOF DECK
SIMPSON H2.5T AT EACH RAFTER BEARING
CONT 2X6
LVL BEAM
SIMPSON A35
ANCHOR
MAIN FLOOR
0' - 0"
A
1'-0"
4'-0" X 8'-0"
3"
HSS COLUMN - SEE PLAN
CJP
1 1/2" NON-SHRINK GROUT
3/4 X 12 X 12 BASE PLATE WITH (4)
3/4" DIA X 12" HEADED ANCHOR
STUDS (9" EMBED ON 9"X9" GAUGE)
(6)#5 LONG AND (9)#5 SHORT
1'-4"
CONCRETE ENCASEMENT BELOW
GRADE WITH 3'' MIN COVER OVER
STEEL
SEE ARCH FOR FINISH
MAIN FLOOR
0' - 0"
6
TIMBER POST
SIMPSON ABA POST BASE AND 1/2"
ANCHOR BOLT
EXISTING SLAB AND FOOTING TO
REMAIN
MAIN FLOOR
0' - 0"
D
EXISTING SLAB TO REMAIN
6"
EQ EQ
MATCH EXISTING BOTTOM OF
FOOTING ELEVATION
NEW CONCRETE FOOTING
1'-6" X 3'-0"
3/16
1 1/2" NON-SHRINK GROUT
3/4 X 4 1/2 X 10 BASE PLATE WITH (2)
3/4" DIA X 12" HEADED ANCHOR
STUDS (9" EMBED ON 7" GAUGE)
NEW HSS COLUMN
EXISTING BRICK WALL TO REMAIN
RAFTER BEARING
10' - 5 1/4"
5
HSS COLUMN
SIMPSON CC COLUMN
CAP SHOP WELDED
TO HSS
LVL BEAM
RAFTER
RAFTER BEARING
10' - 5 1/4"
A B
HSS COLUMN
SIMPSON CC COLUMN
CAP SHOP WELDED TO
HSS
LVL BEAM SIMPSON BA TOP
FLANGE HANGER
TIMBER POST
SIMPSON ECCQ POST
CAP
RAFTER BEARING
10' - 5 1/4"
D
EXISTING BRICK WALL TO
REMAIN
TREATED CONT PLATE WITH
1/2" DIA ADHESIVE ANCHORS
AT 24" (MIN OF 3)
SECTION
S1.1 S2.13/4" = 1'-0"
2 SECTION
S1.1 S2.13/4" = 1'-0"
3
SECTION
S1.1 S2.13/4" = 1'-0"
6 SECTION
S1.1 S2.13/4" = 1'-0"
8SECTION
S1.1 S2.13/4" = 1'-0"
7
SECTION
S1.1 S2.13/4" = 1'-0"
4SECTION
S1.1 S2.13/4" = 1'-0"
1
S2.1
FRAMING AND
FOUNDATION
DETAILS
SECTION
S1.1 S2.13/4" = 1'-0"
5
8'-8"10'-5"8'-8"
2'-1 7/8"13'-1/2"
27'-9"
15'-2 3/8"
ALL (6) EXISTING
SOLID STONE
COLUMNS TO BE
DEMOLISHED
EXISTING PERGOLA
ABOVE TO BE
DEMOLISHED
(4) EXISTING
PILASTERS TO BE
DEMOLISHED
EXISTING BRICK WALL
TO REMAIN; QUOINS
AND STONE COPING TO
BE DEMOLISHED
EXISTING BRICK
CHIMNEY TO REMAINEXISTING PLANTING
BED TO REMAIN
EXISTING BRICK
WALK TO BE
MODIFIED, SALVAGE
& REUSE BRICKS
EXISTING BRICK
WALK TO REMAIN
EXISTING BRICK
BORDER TO REMAIN;
SALVAGE AS NEEDED
FOR NEW FOOTINGS
EXISTING STONE
PAVERS TO REMAIN
EXISTING TREE TO BE
MOVED, LOCATION
ON SITE TBD
APPROX. AREA OF SLAB
TO BE DEMOLISHED FOR
INSTALLATION OF NEW
COLUMN FOOTINGS
1
A2
2
A2
4
A2
4
A2
3
A2
3
A2
4'-3/8" 19'-5 3/4" 4'-3/8"
27'-6 1/2"
4'-3/8"7'-1/2"4'-3/8"
15'-1 1/4"
EQ. EQ.
6'
EXISTING BRICK
WALL TO REMAIN
EXISTING BRICK
CHIMNEY TO REMAIN
EXISTING PLANTING
BED TO REMAIN
EXISTING BRICK
WALK TO REMAIN
EXISTING BRICK
BORDER TO REMAIN
NEW BRICK WALK
CENTERED ON NEW
PERGOLA
EXISTING BRICK
BORDER TO REMAIN
EXISTING STONE
PAVERS TO REMAIN
NEW FURNITURE,
N.I.C.
(6) NEW WRAPPED 6"x6"
STEEL TUBE COLUMNS AT
CORNERS, WITH BASE
PLATES AND NEW
FOOTINGS, BASE PLATES
CONCEALED BELOW
BRICK PAVERS
(4) NEW WRAPPED 6"x6"
STEEL TUBE COLUMNS
IN PLACE OF EXISTING
PILASTERS
WALL MOUNTED TV
LATTICE INFILL BETWEEN
COLUMNS, TYP.
STORAGE
CABINET w/
COUNTER,
N.I.C.
(2) NEW OUTLETS FOR
CHARGING ON THIS WALL
UNDERGROUND RAIN
LEADER TO DAYLIGHT
(3) NEW OUTDOOR
ELEC. FLOOR
OUTLETS
(2) NEW WRAPPED 6"x6"
STEEL TUBE COLUMNS
BEARING ON EXIST. SLAB,
BASE PLATES CONCEALED
BELOW BRICK PAVERS
NEW COLUMN FOOTINGS
(4) NEW WRAPPED
STEEL COLUMNS IN
PLACE OF EXISTING
PILASTERS
DSDS
DS
2
A2
4
A2
4
A2
3
A2
3
A2
STANDING SEAM METAL
ROOF TO MATCH POOL
HOUSE ROOF
HALF-ROUND METAL
GUTTER
HALF-ROUND METAL
GUTTER
HALF-ROUND METAL
GUTTER
RIDGE CAP
DOWNSPOUT
DOWNSPOUTDOWNSPOUT
EXISTING CHIMNEY TO
REMAIN
CRICKET; MATCH SLOPE
OF MASONRY BELOW
10:12 10:12
N
SCALE: 1/4" = 1'-0"
1
DEMO PLAN
0 2' 4' 8'
2
PLAN
3
ROOF PLAN
A1
BIMc loud: bdar chitects - BIMc loud Sof tware as a Service/ 4 Acres Pool/ Four Acres Pool Monda y , Se pte mbe r 8, 20 25 5:42 P M
FOUR ACRES PAVILION
1314 RUGBY ROAD,
CHARLOTTESVILLE, VA 22903
PROJECT #25050
PLANS
ARCHITECT
BUSHMAN DREYFUS ARCHITECTS, PC
820 East High Street, Charlottesville VA
434.295.1936
STRUCTURAL ENGINEER
DUNBAR
110 Third Street, Charlottesville VA
434.293.5171
ID ISSUE NAME DATE
01 PERMIT SET 09.08.2025
2x2 LATTICE INFILL
BETWEEN COLUMNS,
TYP.
STANDING SEAM METAL
ROOF, MATCH POOL
HOUSE ROOF
EXISTING BRICK
CHIMNEY
WRAPPED STEEL
COLUMNS
HALF-ROUND METAL
GUTTER
NEW DOWNSPOUT
10:12
EXISTING
BRICK
EXISTING
BRICK
EXISTING
BRICK
(OPEN)
WALL
MOUNTED
TV
STANDING SEAM METAL
ROOF, MATCH POOL
HOUSE ROOF
EXISTING BRICK
CHIMNEY
2x2 LATTICE INFILL
WRAPPED STEEL
COLUMNS
EXISTING BRICK WALL
TO REMAIN.
NEW HALF ROUND
GUTTERS
(2) NEW
DOWNSPOUTS
CRICKET
BEYOND
NEW BRICK COPING
COURSE ON EXISTING
BRICK WALL TO MATCH
POOL WALLS
12
10
(OPEN)
(OPEN)(OPEN)
9'-4 1/4"
10'-5 1/4"
STANDING SEAM METAL
ROOF, MATCH POOL
HOUSE ROOF
EXISTING BRICK
CHIMNEY
2x2 LATTICE INFILL
WRAPPED STEEL
COLUMN PER STRUCT.
(3) 1 ¾" x 11 7/8" LVL
BEAM, TRIMMED OUT
STEEL CABLE TIE PER
STRUCT.
NEW COLUMN
FOOTER PER
STRUCT.
CRICKET
BEYOND
EXIST. FOOTER
TO REMAIN
AIMABLE SPOT LIGHT IN
EVERY RAFTER BAY ON
BOTH SIDES
EXIST. BRICK WALL
TRIMMED OUT RIDGE
BEAM
WRAPPED STEEL COLUMNS
IN PLACE OF EXISTING
PILASTERS. SEE STRUCT.
BROMIC PLATINUM SMART-
HEAT ELECTRIC OUTDOOR
PATIO HEATER; WHITE
NEW COLUMN
FOOTER PER
STRUCT.
WRAPPED STEEL
COLUMN PER STRUCT.
NEW BRICK COPING
COURSE ON EXISTING
BRICK WALL TO MATCH
POOL WALLS
(OPEN)(OPEN)
12
10
1'
(4) WRAPPED STEEL COLUMNS
IN PLACE OF EXISTING STONE
PILASTERS. SEE STRUCT.
2x2 LATTICE INFILL
STRUCTURAL T&G
DECKING, PTD.
STEEL CABLE TIE
4x10 HEAVY TIMBER
RAFTERS, PTD.
(2) CEILING FANS
EXISTING BRICK
CHIMNEY
DECORATIVE PENDANT LIGHT FIXTURE
AIMABLE SPOT LIGHT IN EVERY
RAFTER BAY ON BOTH SIDES
BROMIC PLATINUM SMART-HEAT
ELECTRIC OUTDOOR PATIO
HEATER; WHITE
EXISTING
BRICK
EXISTING
BRICK
EXISTING
BRICK
WALL
MOUNTED
TV
OPENOPEN
3
E-W SECTION
SCALE: 1/4" = 1'-0"
1
NORTH ELEVATION
0 2' 4' 8'
2
EAST ELEVATION
4
N-S SECTION
NOTE:
FINISH MATERIAL FOR ALL TRIM, COLUMN WRAPS AND LATTICE TO BE AZEK OR EQUAL.
A2
BIMc loud: bdar chitects - BIMc loud Sof tware as a Service/ 4 Acres Pool/ Four Acres Pool Monda y , Se pte mbe r 8, 20 25 5:42 P M
FOUR ACRES PAVILION
1314 RUGBY ROAD,
CHARLOTTESVILLE, VA 22903
PROJECT #25050
ELEVATIONS &
SECTIONS
ARCHITECT
BUSHMAN DREYFUS ARCHITECTS, PC
820 East High Street, Charlottesville VA
434.295.1936
STRUCTURAL ENGINEER
DUNBAR
110 Third Street, Charlottesville VA
434.293.5171
ID ISSUE NAME DATE
01 PERMIT SET 09.08.2025
NOT TO SCALE
1VIEW FROM POOL LOOKING SOUTHEAST2VIEW ACROSS POOL
3VIEW FROM PARKING COURT4INTERIOR VIEW LOOKING EAST
A2.1
BIMc loud: bdar chitects - BIMc loud Sof tware as a Service/ 4 Acres Pool/ Four Acres Pool Monda y , October 27, 20 25 11: 2 6 P M
FOUR ACRES PAVILION
1314 RUGBY ROAD,
CHARLOTTESVILLE, VA 22903
PROJECT # 25050
3D VIEWS
ARCHITECT
BUSHMAN DREYFUS ARCHITECTS, PC
820 East High Street, Charlottesville VA
434.295.1936
STRUCTURAL ENGINEER
DUNBAR
110 Third Street, Charlottesville VA
434.293.5171
ID ISSUE NAME DATE
1314 Rugby Road. Four Acres - Pool Pavilion. CoA request November 18, 2025. Sheet 1 of 4.
Existing
Pavilion
Pool
Garage
Four Acres, 1910
1314 Rugby Road. Four Acres - Pool Pavilion. CoA request November 18, 2025. Site plan from 2019 submission. For context only. Sheet 2 of 4.
Garage
Pool
Pavilion
1314 Rugby Road. Four Acres - Pool Pavilion. CoA request November 18, 2025: Photos from 2019 submission. For context only. Sheet 3 of 4.
Existing Pavilion Proposed New Pavilion, November 2025
Existing structures
1314 Rugby Road. Four Acres - Pool Pavilion. CoA request November 18, 2025: Photos from 2019 submission. For context only. Sheet 4 of 4.
159 Madison Lane – November 18, 2025 BAR (11/12) 1
City of Charlottesville
Board of Architectural Review
Staff Report
November 18, 2025
Certificate of Appropriateness
BAR 22-06-05 (deferred application)
BAR # HST25-0112
159 Madison Lane, TMP 090145000
The Corner ADC District (contributing)
Owner: Montalto Corporation
Applicant: Paul Tassell, The Gaines Group
Project: Masonry repairs and rehabilitation work at south elevation
Background
Year Built: 1928
District: The Corner ADC District
Status: Contributing
Fraternity house designed by UVA architecture professor Stanislaw Makielski. Prominently situated
at the north edge of the Madison Bowl, the five-bay, two-story brick house has a two-story Tuscan-
columned portico at its center.
Prior BAR Review
September 18, 2007 - BAR approved (8-0) CoA for Chippendale railing on roof, painted white.
April 18, 2017 – BAR approved (7-0) CoA for an accessible brick and metal ramp at the building’s
northeast corner and the associated installation of a landscape planter and light fixture.
June 22, 2022 - BAR approved (5-0) CoA to infill with brick the three, basement-level windows at
the front of the porch with the condition that the coursing, brick color and mortar be matched as
closely to the historic as possible, and that the brick infill be set back several inches from the plane
of the brick wall.
159 Madison Lane - BAR June 22 2022
Application
• Applicant submittal: Gaines Group Architects Phi Kappa Psi Fraternity House – BAR
Submittal, dated November 22, 2024, 10 pages.
159 Madison Lane – November 18, 2025 BAR (11/12) 2
• Excerpts from Stanislaw Makielski drawings dated February 1, 1928, showing the side stairs at
the south portico.
The project narrative identifies several elements that staff has determined are maintenance and
repair, and therefore not subject to BAR review. The elements subject to this CoA request are as
follows:
o Removal and reconstruction of the concrete (lower) stairs on the west side of the portico.
o Removal and reconstruction of the brick and concrete (upper) stairs on the east and west
sides of the portico. In lieu of the concrete caps on the outside stingers, the new concrete
treads will be exposed with a 1” overhang. This will replicate the original design at these
stairs, which is shown on the original Makielski drawings dated February 1, 1928.
o Install a metal door and frame at the lower wall at the west side of the portico.
o The proposed work includes infilling with brick the three, basement-level windows at
the front of the porch. The BAR approved that work with conditions in June 2022;
however, that CoA expired.
Discussion and Recommendations
Generally, the proposed work falls under either maintenance and repair or appropriate
rehabilitation. Staff finds the proposed work to be appropriate and consistent with the guidelines
and therefore recommends approval with the conditions noted below.
o Existing railings will be reused; however, if existing are salvageable, the new will
reasonably replicate the existing, with the understanding that dimensions might be modified
to meet code requirements.
o Approval of the infill with brick the three, basement-level windows at the front of the porch
with the condition that the coursing, brick color and mortar be matched as closely to the
historic as possible, and that the brick infill be set back several inches from the plane of the
brick wall.
Suggested Motion
Approval: Having considered the standards set forth within the City Code, including City’s ADC
District Design Guidelines, I move to find that the proposed masonry-related rehabilitation work at
159 Madison Lane satisfies the BAR’s criteria and is compatible with this district and that the BAR
approves the application [as submitted].
[…as submitted with the following conditions: …]
Denial: Having considered the standards set forth within the City Code, including City’s ADC
District Design Guidelines, I move to find that the proposed masonry-related rehabilitation work at
159 Madison Lane does not satisfy the BAR’s criteria and is not compatible with this district, and
that for the following reasons the BAR denies the application as submitted:
Criteria, Standards, and Guidelines
Criteria and Guidelines
Note re: BAR authority: Per Code, the BAR is charged only with the authority to approve or deny a
design review CoA, following an evaluation applying the criteria under Code Sec. 34-5.2.7. Major
Historic Review. The BAR does not evaluate a proposed use. Additionally, per Code Sec. 34-
159 Madison Lane – November 18, 2025 BAR (11/12) 3
5.2.7.E.2., the issuance of a CoA “cannot, in and of itself, authorize any construction,
reconstruction, alteration, repair, demolition, or other improvements or activities requiring a
building permit. Where a building permit is required, no activity authorized by a [CoA] is lawful
unless conducted in accordance with the required building permit and all applicable building code
requirements.”
Review Criteria Generally
Per Chapter 34, Div. 5.2.7. C.2:
a. In considering a particular application the BAR will approve the application unless it finds:
i. That the proposal does not meet specific standards set forth within this Section or applicable
provisions of the City’s design guidelines; and
ii. ii. The proposal is incompatible with the historic, cultural or architectural character of the
district in which the property is located or the IPP that is the subject of the application.
b. The BAR will approve, approve with conditions, or deny applications for Certificates of
Appropriateness in accordance with the provisions of this Section.
c. The BAR, or City Council on appeal, may require conditions of approval as are necessary or
desirable to ensure that any new construction or addition is compatible with the scale and
character of the Architecture Design Control District, Individually Protected Property, or
Historic Conservation District. Prior to attaching conditions to an approval, due consideration
will be given to the cost of compliance with the proposed conditions as well as the goals of the
Comprehensive Plan. Conditions may require a reduction in height or massing, consistent with
the City’s design guidelines and subject to the following limitations [not germane]:
Standards for Review and Decision
Per Chapter 34, Div. 5.2.7. D.1:
a. Review of the proposed construction, reconstruction, alteration or restoration of a building or
structure is limited to exterior architectural features, including signs, and the following features
and factors:
i. Whether the material, texture, color, height, scale, mass, and placement of the proposed
addition, modification or construction are visually and architecturally compatible with
the site and the applicable District;
ii. The harmony of the proposed change in terms of overall proportion and the size and
placement of entrances, windows, awnings, exterior stairs, and signs;
iii. The Secretary of the Interior Standards for Rehabilitation set forth within the Code of
Federal Regulations (36 C.F.R. §67.7(b)), as may be relevant;
iv. The effect of the proposed change on the adjacent building or structures;
v. The impact of the proposed change on other protected features on the property, such as
gardens, landscaping, fences, walls, and walks;
vi. Whether the proposed method of construction, renovation, or restoration could have an
adverse impact on the structure or site, or adjacent buildings or structures;
vii. When reviewing any proposed sign as part of an application under consideration, the
standards set forth within Div. 4.11. Signs will be applied; and
viii. Any applicable provisions of the City’s design guidelines.
Links to ADC District Design Guidelines
Chapter 1 Introduction (Part 1)
Chapter 1 Introduction (Part 2)
Chapter 2 Site Design and Elements
159 Madison Lane – November 18, 2025 BAR (11/12) 4
Chapter 3 New Construction and Additions
Chapter 4 Rehabilitation
Pertinent ADC District Design Guidelines
Chapter 4 – Rehabilitation
A. Introduction
These design review guidelines are based on the Secretary of the Interior’s Standards for
Rehabilitation, found on page 1.8. “Rehabilitation” is defined as “the process of returning a property
to a state of utility, through repair or alteration, which makes possible an efficient contemporary use
while preserving those portions and features of the property which are significant to its historic,
architectural, and cultural values.”
Rehabilitation assumes that at least some repair or alteration of the historic building will be needed
in order to provide for an efficient contemporary use; however, these repairs and alterations must
not damage or destroy materials, features or finishes that are important in defining the building’s
historic character. Also, exterior additions should not duplicate the form, material, and detailing of
the structure to the extent that they compromise the historic character of the structure.
The distinction between rehabilitation and restoration is often not made, causing confusion among
building owners and their architect or contractor. Restoration is an effort to return a building to a
particular state at a particular time in its history, most often as it was originally built. Restoration
projects are less concerned with modern amenities; in fact, they are often removed in order to
capture a sense of the building at a certain time in its history. Rehabilitation is recognized as the act
of bringing an old building into use by adding modern amenities, meeting current building codes,
and providing a use that is viable
D. Entrances, Porches, and Doors
1) The original details and shape of porches should be retained including the outline, roof height,
and roof pitch.
2) Inspect masonry, wood, and metal or porches and entrances for signs of rust, peeling paint,
wood deterioration, open joints around frames, deteriorating putty, inadequate caulking, and
improper drainage, and correct any of these conditions.
3) Repair damaged elements, matching the detail of the existing original fabric.
4) Replace an entire porch only if it is too deteriorated to repair or is completely missing, and
design to match the original as closely as possible.
5) Do not strip entrances and porches of historic material and details.
6) Give more importance to front or side porches than to utilitarian back porches.
7) Do not remove or radically change entrances and porches important in defining the building’s
overall historic character.
8) Avoid adding decorative elements incompatible with the existing structure.
[…]
F. Foundation
1) Retain any decorative vents that are original to the building.
2) Offset infill between brick piers either with concrete block or solid masonry to ensure that a
primary reading of a brick foundation is retained.
159 Madison Lane – November 18, 2025 BAR (11/12) 5
3) When repointing or rebuilding deteriorated porch piers, match original materials as closely as
possible.
4) Where masonry has deteriorated, take steps as outlined in the masonry section of these
guidelines.
H. Masonry
1) Retain masonry features, such as walls, brackets, railings, cornices, window surrounds,
pediments, steps, and columns that are important in defining the overall character of the
building.
2) When repairing or replacing a masonry feature, respect the size, texture, color, and pattern of
masonry units, as well as mortar joint size and tooling.
3) When repointing masonry, duplicate mortar strength, composition, color, and texture.
a. Do not repoint with mortar that is stronger than the original mortar and the brick itself.
b. Do not repoint with a synthetic caulking compound.
4) Repoint to match original joints and retain the original joint width.
5) Do not paint unpainted masonry.
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
PROJECT NAME:
U.V.A. Alpha Chapter of Phi Kappa Psi Fraternity House
PROJECT ADDRESS:
159 Madison Lane
PARCEL NUMBER:
090145000
PROJECT DESCRIPTION:
This project aims to provide a restoration plan for the Phi Kappa Psi Fraternity house specifically pertaining to the exterior
spaces located on the west, south, and east facades. The building has experienced significant brick and structural
deterioration due to decades of water infiltration. Our plan is to develop a clear strategy for preservation and restoration
while ensuring the building’s safety and longevity.
KEY OBJECTIVES:
1. Structural replacement: New structural slab for the portico floor/basement ceiling, walkways, and stairs.
2. Brick restoration: Brick restoration to solve the impact of water infiltration, efflorescence, spalling, and mortar
deterioration. Masonry will be properly flashed at transitions.
3. Water infiltration solutions: New drainage solution for removing water from portico floor by three floor drains to carry
water away. New drainage solution also for the west elevated entry by one floor drain. All walkways are sloped away
from the main building and properly flashed.
4. Preservation and Restoration: Brick & masonry detailing will be restored to original appearance. Handrails will be
reinstalled to improve safety while maintaining the original look.
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
VICINITY MAP
MADISON BOWL
RUGBY ROAD
MADISON LANE
N
PHI KAPPA PSI
FRATERNITY
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
EXISTING CONDITIONS - SOUTH ELEVATION
Right side exterior stair has experienced
deterioration to the brick and slab due to
water infiltration and winter salts causing
cracking, spalling, corrosion to railing,
discoloration & staining, and overall
weakening.
In response to constant vandalism, plywood
was used to infill window openings.
Elevated slab has experienced deterioration
over time due to water infiltration causing
cracking, spalling, corrosion of reinforcement,
discoloration & staining, and overall
weakening.
Left side exterior stair has experienced
deterioration to the brick and slab due to
water infiltration and winter salts causing
cracking, spalling, corrosion to railing,
discoloration & staining, and overall
weakening.
Portico surface has experienced deterioration
over time due to water infiltration causing
cracking, spalling, corrosion of reinforcement,
discoloration & staining, and overall
weakening.
Face brick has experienced deterioration
over time due to water infiltration causing
cracking, bowing, efflorescence, discoloration
& staining, and overall weakening.
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
EXISTING CONDITIONS - WEST ELEVATION
Elevated slab has experienced deterioration
over time due to water infiltration causing
cracking, spalling, corrosion of reinforcement,
discoloration & staining, and overall
weakening.
In response to constant vandalism, plywood
was used to infill opening below elevated
slab.
Exterior stair has experienced deterioration
to the brick and slab due to water infiltration
and winter salts causing cracking, spalling,
corrosion to railing, discoloration & staining,
and overall weakening.
Face brick has experienced deterioration
over time due to water infiltration causing
cracking, bowing, efflorescence, discoloration
& staining, and overall weakening. Metal railing attachment to staircase is
compromised due to water infiltration.
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
EXISTING CONDITIONS - VARIOUS
FRONT PORTICO -
DETERIORATION TO PRECAST
EXPOSING REINFORCING
RIGHT SIDE EXTERIOR STAIRS -
DETERIORATION TO CONCRETE AND
BRICK & PREVIOUS ATTEMPTS AT REPAIR
FRONT PORTICO -
BRICK DETERIORATION
PLYWOOD INFILLS TO WINDOWS
LEFT SIDE EXTERIOR STAIRS -
DETERIORATION TO CONCRETE AND
BRICK & PREVIOUS ATTEMPTS AT REPAIR
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
FRONT PORTICO BASEMENT WINDOWS -
Portico basement windows have been boarded
up due to vandalism. We are proposing infilling
these window openings with brick that matches
the existing, recessed 1/4”.
EXTERIOR STAIR NOSING -
Exterior stair nosings have seen various repairs
to solve deterioration and to re-secure railings
to stairs. Exterior stairs will return to their original
design of 1 1/2” bull-nosed concrete treads and
a 1” overhang.
PROPOSED IMPROVEMENTS
EXISTING
PROPOSED
PROPOSED
EXISTING
PHI KAPPA PSI FRATERNITY HOUSE - BAR SUBMITTAL
PREPARED BY THE GAINES GROUP ARCHITECTS - 11-22-24
UNDER STAIR ACCESS -
To make the under stair access more secure and
permanent we are proposing a metal, 36” x 48”,
lockable access door. Door will be painted white
to match all doors and utility panels located
around the exterior of building.
PROPOSED IMPROVEMENTS
EXISTING
PROPOSED
UVA PHI KAPPA PSI FRATERNITY HOUSE
BAR SUBMITTAL PREPARED BY
THE GAINES GROUP ARCHITECTS
11-11-25
ORIGINAL DRAWINGS BY
STANISLAW J. MAKIELSKI ARCHITECT
CHARLOTTESVILLE, VA
DATED FEBRUARY 1, 1928
FIRST FLOOR PLAN
The first floor plan shows concrete treads
overhanging the face of brick below (dashed
line) both on the side and front.
UVA PHI KAPPA PSI FRATERNITY HOUSE
BAR SUBMITTAL PREPARED BY
THE GAINES GROUP ARCHITECTS
11-11-25
ORIGINAL DRAWINGS BY
STANISLAW J. MAKIELSKI ARCHITECT
CHARLOTTESVILLE, VA
DATED FEBRUARY 1, 1928
FRONT ELEVATION
The front elevation shows concrete treads with
a bull-nosed edge.
UVA PHI KAPPA PSI FRATERNITY HOUSE
BAR SUBMITTAL PREPARED BY
THE GAINES GROUP ARCHITECTS
11-11-25
ORIGINAL DRAWINGS BY
STANISLAW J. MAKIELSKI ARCHITECT
CHARLOTTESVILLE, VA
DATED FEBRUARY 1, 1928
SIDE ELEVATIONS
The side elevations shows concrete treads with
a bull-nosed edge.
Source: City of Charlottesville website. First collected Oct 27, 2026.