Planning Commission Special Meeting — Agenda Packet
City of Charlottesville · Charlottesville City County · Planning Commission · meeting of Feb 25, 2025 · Agenda packets
Open the original document More from City of Charlottesville
This document is no longer listed on City of Charlottesville's website. We kept the copy we read.
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
November 10, 2021
Please Take Notice
The Charlottesville Planning Commission will hold a Special Meeting on
Tuesday February 25, 2025, at 5pm in the Charlottesville Council Chambers,
605 East Main Street, Charlottesville, VA 22902 and Electronic/Virtual.
AGENDA
1. Matters from the Public
2. Special Exception – Critical Slope – 1115 St Charles Court
3. Special Exception – Fence – 820 East Jefferson Street (Cumbre)
4. Special Exception – Street Facing Entries – Friendship Court Phase
3(400-426 Garrett Street)
Materials for this meeting are available here:
Events • Agendas & Minutes • CivicClerk
Individuals with disabilities who require assistance or special arrangements
to participate in the public meeting may call the ADA Coordinator at (434)
970-3182 or submit a request via email to ada@charlottesville.gov . The City
of Charlottesville requests that you provide a 48 hour notice so that proper
arrangements may be made.
CITY OF CHARLOTTESVILLE
Department of Neighborhood Development Services
City Hall Post Office Box 911
Charlottesville, Virginia 22902
Telephone 434-970-3182
Fax 434-970-3359
www.charlottesville.gov
Page 1 of 5
CITY OF CHARLOTTESVILLE
DEPARTMENT OF NEIGHBORHOOD DEVELOPMENT SERVICES
STAFF REPORT
PLANNING COMMISSION REGULAR MEETING
APPLICATION FOR A CRITICAL SLOPE SPECIAL EXCEPTION
APPLICATION NUMBER: PL-24-0107
DATE OF MEETING: February 11, 2025
Project Planner: Dannan O’Connell, AICP
Date of Staff Report: January 27, 2025
Applicant: Matthew Morrill
Current Property Owner: Matthew and Emily Morrill
Application Information
Property Street Address: 1115 St. Charles Court
Tax Map & Parcel/Tax Status: 48A041B08 (real estate taxes paid current – Sec. 34-12)
Total Project Area (Limits of Disturbance): 1,030 sq. ft.
Total Area of Critical Slopes on Parcels: 3,600 sq. ft. | 50%
Area of Proposed Critical Slope Disturbance: 500 sq. ft. | 7% of total site area | 13.8% of total
critical slopes area on parcel
Comprehensive Plan (General Land Use Plan): General Residential
Current Zoning Classification: R-A
Overlay District: None
Applicant’s Request (Summary)
Matt Morrill (applicant and property owner) wishes to improve the above-referenced property
with a retaining wall, patio, paved path and accessory shed. The proposed improvements will
impact critical slopes on-site as defined by Section 34-4.10.1.B.1. Per Section 34-4.10.1.D a
request for a critical slope special exception must be heard by the Planning Commission before
these improvements can be permitted.
Improvements specific to areas where critical slopes would be impacted should the waiver be
approved are shown on a Sketch Plan (Attachment A) and include a retaining wall, patio, metal
fence, side yard shed, paved path, and associated land disturbance/grading. Critical slope areas
are shown by the applicant in the Critical Slope Exhibit (Attachment C).
PL-24-0107 1115 St. Charles Ct Critical Slope
Page 2 of 5
Existing critical slopes areas located on this Property approximately 3,600 square feet or 50
percent of the site. The applicable definition of “critical slope” is as follows:
1. A grade of 25% or greater;
2. A portion of the slope has a horizontal run of greater than 20 feet;
3. An area of 6,000 square feet or greater; and
4. A portion of the slope is within 200 feet of any waterway protected by the
Standard and Design Manual or Chapter 10 of the Charlottesville Code of
Ordinances, or shown on the map entitled “Properties Impacted by Critical
Slopes”, maintained by the Neighborhood Development Services. (Sec. 34-
4.10.1.B.2)
Based on the information presented within the application materials, Staff verifies that
the area for which this waiver is sought meets all of the above-referenced components
of the definition of “critical slope”.
Vicinity Map
PL-24-0107 1115 St. Charles Ct Critical Slope
Page 3 of 5
Critical Slopes per the Zoning Ordinance
Standard of Review
Per Sec. 34-5.2.16, The Planning Commission will review the application and report its findings
and recommendations to the City Council. City Council may then grant a Critical Slopes Special
Exception when it finds that:
a. Due to unusual size, topography, shape, location, or other unusual physical conditions,
or existing development of a property, the requirements of 4.10.1. Critical Slopes would
effectively prohibit or unreasonably restrict the use, reuse or redevelopment of such
property or would result in significant degradation of the site or adjacent properties; or
b. The public benefit of the proposed encroachment outweighs the public benefit of
protecting the area of slope proposed to be impacted.
City Council will review an application for a Critical Slopes Special Exception according to the
following criteria:
a. Whether the amount of impact has been limited to the greatest extent possible;
b. Whether sufficient mitigation has been proposed to limit the impact of the proposed
encroachment;
PL-24-0107 1115 St. Charles Ct Critical Slope
Page 4 of 5
c. Whether steps have been taken to limit or prevent impacts to portions of the sloped
area with environmental or scenic value or vulnerability to disturbance; and
d. Whether the proposed project is consistent with the zoning district and Comprehensive
Plan.
Project Review and Analysis
A sketch plan of the proposed retaining wall and yard improvements has been provided by the
applicant (Attachment A), along with a survey of the existing property (Attachment B).
Staff Analysis 34-5.2.16.D.1, Criteria A:
Planning Department: The subject property is designated General Residential by the
Comprehensive Plan’s Future Land Use Map. No additional dwelling units are proposed for the
subject property. The existing use and proposed improvements are consistent with the
Comprehensive Plan.
Staff finds that due to the topography of the area and the existing subdivision development, the
requirements of Sec. 34-4.10.1 would unreasonably restrict the use of the subject property. The
critical slope area to be disturbed is minimal, and limited to the area to the rear and side of the
existing residential structure.
Utilities Department: A private drainage easement runs through the project area on the subject
property. Per City Utilities, placement of structures and hardened surfaces within easement
boundaries is subject to approval and may not necessarily be accepted. If this special exception
is approved, a Development Plan to permit the proposed improvements must be submitted to
and approved by City staff before construction permits can be issued.
Staff Analysis 34-5.2.16.D.1, Criteria B:
As the area in question is privately held, and no additional dwellings or public improvements
are proposed, staff finds that Criteria B is not applicable to this request.
Staff Recommendation
Staff recommends the Planning Commission consider the following when making a
recommendation to City Council:
Purpose and Intent of the Critical Slope Provisions
The purpose and intent of the critical slope provisions in Section 34-4.10.1 are to protect and
maintain the environmental quality in the City by limiting development and disturbance of
steeply sloped areas near waterways, adjacent properties, and environmentally sensitive areas
PL-24-0107 1115 St. Charles Ct Critical Slope
Page 5 of 5
and to protect those steeply sloped areas and waterways from the negative impacts of erosion
and stormwater as well as preserve their ecological value.
Recommended Conditions
Staff has no recommendations for conditions related to this project and recommends approval
of this Special Exception.
Suggested Motions
1. “I move to recommend approval of the critical slope special exception for Tax Map and
Parcel 48A041B08 as requested, with no reservations or conditions, based on a finding
that [reference at least one]:
• Due to unusual size, topography, shape, location, or other unusual physical
conditions, or existing development of a property, the requirements of Section 34-
4.10.1 would effectively prohibit or unreasonably restrict the use, reuse or
redevelopment of such property or would result in significant degradation of the
site or adjacent properties.”
• The public benefit of the proposed encroachment outweighs the public benefit of
protecting the area of slope proposed to be impacted.”
2. “I move to recommend denial of the critical slope special exception for Tax Map and
Parcel 48A041B08.”
Attachments
A. Sketch Plan
B. Property Survey
C. Critical Slope Exhibit
Attachment A – Sketch Plat
Attachment B - Property Survey
Attachment C – Critical Slopes
PLANNING COMMISSION REGULAR MEETING
APPLICATION FOR A SPECIAL EXCEPTION PERMIT
APPLICATION NUMBER: PL-24-0132
DATE OF MEETING: February 11, 2025
DEPARTMENT OF NEIGHBORHOOD DEVELOPMENT SERVICES STAFF REPORT
Project Planner: Carrie Rainey
Date of Staff Report: February 4, 2025
Applicant: Reid Murphy, East Jefferson Assemblage, LLC
Applicant’s Representative(s): Bob Pineo, Design Develop, LLC
Current Property Owner: East Jefferson Assemblage, LLC
Application Information
Property Street Address: 818-820 E Jefferson Street (“Subject Property”)
Tax Map & Parcel/Tax Status: 53018000 (real estate taxes paid current - Sec. 34-5.2.1.C.3.e)
Total Square Footage/ Acreage Site: Approx. 0.67 acres (29,050 square feet)
Comprehensive Plan (General Land Use Plan): Urban Mixed Use Node
Current Zoning Classification: NX-10 Node Mixed Use
Overlay District: Entrance Corridor Overlay District
Applicant’s Request (Summary)
The applicant requests a Special Exception Permit (SEP) pursuant to City Code Sections 34-
2.5.5.B.6 and 34-5.2.15, which states a SEP may be granted for physical dimensional standards.
The applicant has requested to install fencing on a proposed deck in the front and side street
yards on 9th Street NE and E Jefferson Street. Per Section 34-2.10.1.B.1.d, 9th Street NE is
designated as the primary street and E Jefferson Street is designated as the side street. The NX-
10 Node Mixed Use district does not permit fencing in front yards or side street yards unless a
SEP is granted. Virginia Building Code requires the deck, which is more than 30 inches above
grade, to have vertical protection (guardrails/fencing). The subject property has street frontage
on 9th Street NE and E Jefferson Street and is located within an Entrance Corridor Overlay
District.
CITY OF CHARLOTTESVILLE
Department of Neighborhood Development Services
City Hall Post Office Box 911
Charlottesville, Virginia 22902
Telephone 434-970-3182
Fax 434-970-3359
www.charlottesville.gov
Page 2 of 6
Vicinity Map
Context Map 1
NORTH
Page 3 of 6
Context Map 2- Zoning Classifications
Context Map 3- Future Land Use Plan, 2021 Comprehensive Plan
NX-10
DX
CX-5
CV
Urban Mixed Use Node
Downtown Core
Civic
CX-8
Neighborhood
Mixed Use
Corridor
Urban Mixed
Use Corridor
Open Space
and Parks
NORTH
NORTH
Page 4 of 6
Standard of Review
City Council may grant an applicant a Special Exception Permit (SEP), giving consideration to a
number of factors set forth within Zoning Ordinance Section 34-5.2.15.D. If Council finds that a
proposed use or development will have potentially adverse impacts, and if Council identifies
development conditions that could satisfactorily mitigate such impacts, then Council may set
forth reasonable conditions within its SEP approval. The role of the Planning Commission is to
make an advisory recommendation to the City Council, as to (i) whether or not Council should
approve a proposed SEP and if so, (ii) whether there are any reasonable development
conditions that could mitigate potentially adverse impacts of the proposed development.
Section 34-5.2.15.D of the City’s Zoning Ordinance lists a number of factors that Council will
consider in making a decision on a proposed SEP. Following below is staff’s analysis of those
factors, based on the information provided by the applicant.
(1) Whether the proposed modifications to physical dimensional standards will be
harmonious with existing and approved patterns of development on the same or an
opposing block face or abutting property;
The applicant proposes to create additional seating areas for the existing food and beverage
use by installing a new deck along the northern and eastern side of the existing building.
The Virginia Building Code requires fencing as the deck is more than 30 inches above the
ground.
Staff Analysis: Other properties along 9th Street NE in the vicinity of the subject property
vary in building setback and front yard use. The front yard areas of these properties vary in
depth and include parking lots and landscaping. Other properties along E Jefferson Street
vary from larger multi-unit residential and commercial buildings to single unit houses
generally converted to office or commercial uses. The front yard areas of these properties
are generally a similar depth to the subject property and landscaped. The proposed
improvements are harmonious with the existing patterns of development within the
neighborhood.
Entrance Corridor Overlay Review
While Section 34-5.2.15 does not require review of SEP applications by the Preservation
Planner (Administrator for Corridor Review per Section 34-5.2.8), the applicant received a
Certificate of Appropriateness for Corridor Review for the proposed improvements on
November 21, 2023. See Attachment B for more information.
Page 5 of 6
(2) Whether the proposed modification supports the goals and strategies of the
Comprehensive Plan;
Below are specific areas of the Comprehensive Plan for which the development is in
compliance:
a. Land Use, Urban Form, and Historic & Cultural Preservation
Objectives for Mixed-Use Areas: Promote and encourage design elements that
enhance community livability such as active uses at the ground floor level along
key street frontages.
Goal 3: Protect and enhance the existing distinct identities of the city’s
neighborhoods and places while promoting and prioritizing infill development,
housing options, a mix of uses, and sustainable reuse in our community.
Strategy 7.1: Within Entrance Corridors, encourage placemaking elements and
look for opportunities to support community-centered destinations.
Comprehensive Plan- Staff Analysis:
The Future Land Use Plan of the 2021 Comprehensive Plan designates the subject property
and surrounding properties as Urban Mixed Use Node, which is urban mixed use districts
that support community housing, employment, and commercial development. The proposed
fencing will allow the creation of an outdoor seating area adjacent to and visible from 9th
Street NE and E Jefferson Street, which will increase activation and pedestrian interest on
both streets. In addition, the new seating area supports commercial development by
increasing the capacity of the existing restaurant (general food and beverage) use.
Several goals in the Comprehensive Plan speak to a desire for context sensitive
redevelopment. The Preservation Planner has confirmed the proposed fencing is
compatible with the Entrance Corridor Overlay district. Staff finds the proposed
improvements support the goals and strategies of the Comprehensive Plan.
(3) Whether, with conditions, the Special Exception Permit is consistent with the public
necessity, convenience, general welfare, and good zoning practice.
As the application aligns with the Comprehensive Plan and provides outdoor space and
street activation for 9th Street NE and E Jefferson Street, staff finds granting the Special
Exception Permit is consistent with good zoning practice and general public welfare.
Public Comments Received
Staff has received no public comments at the publishing of this report.
Page 6 of 6
Staff Recommendation
Staff recommends the Planning Commission recommend approval of the Special Exception
Permit to permit the installation of fences and gates on the subject property.
Recommended Conditions
Staff does not recommend any conditions be placed on this Special Exception Permit. Any
proposed modifications to the fence and gate details will be reviewed by staff for consistency
with the issued Corridor Review Certificate of Appropriateness.
Suggested Motions
1. I move to recommend approval of this application for a Special Exception Permit in the
NX-10 Node Mixed Use zone at 818-820 E Jefferson Street to permit the installation of
fences.
a. [condition(s) proposed by Planning Commission]
OR,
2. I move to recommend denial of this application for a Special Exception Permit in the NX-
10 Node Mixed Use zone at 818-820 E Jefferson Street to permit the installation of
fences.
Attachments
A. Minor Development Plan received January 29, 2025
B. Entrance Corridor Certificate of Appropriateness granted November 21, 2023
TMP 53-180
TMP 53-178
VACATED
Parcel is zoned Node Mixed-Use 10 (NX-10)
and is in the Entrance Corridors Overlay District
Intended Use is General Food & Beverage
(up to 4,00 sf) with an accessory use for
on-site alcohol consumption
EXISTING CONDITIONS
1' - 8"2' - 0"4' - 7"
PROPERTY LINE
PAVING
PROPERTY LINE
13' - 10 1/2"
21' - 1 1/2"
21' - 6"
428 SFT
A3
A-101
C3
A-101
PAVING
PAVEMENT
2' - 3"6' - 0"
1' - 11 1/2"
7' - 4"
2' - 3"3' - 4"5' - 10 1/2"0' - 6"20' - 7"21' - 5 1/2"
VEGETATION BUFFER
16' - 0" 8' - 5 1/2" 1' - 8" 1' - 11 1/2" 6' - 0 1/2" 2' - 3"
-0' - 5 1/2"
0' - 0"
0' - 0"
0' - 0"
3/8" / 1'-0"
-0' - 5 1/2"
42' - 8"
FINISHED FLOOR
LEVEL
0' - 0"
Roof
11' - 8"
Ceiling Lvl
8' - 0"
A3
A-101
ROAD
9' - 3"
PAVING
2' - 3"
PAVEMENT
6' - 0 1/2"
BUFFER
1' - 11 1/2"
SETBACK
1' - 8"
DECK
8' - 5 1/2"
EXISTING BUILDING
16' - 0"
PROPERTY LINE
FINISHED FLOOR
LEVEL
0' - 0"
Roof
11' - 8"
Ceiling Lvl
8' - 0"
C3
A-101
ROADPAVEMENT
10' - 2"
SETBACK
0' - 6"
DECK
21' - 0"
DECK-SEATING
21' - 5 1/2"
PROPERTY LINE
EXISTING RAILING
TO REMAIN
www.designdevelopllc.com
Scale
Project number
Date
Drawn by
Checked by
ARCHITECT
Design Develop, LLC
802 East Jefferson St.
Suite B3
Charlottesville, VA 22902
434.806.8365
Contact: Bob Pineo
Email: bob@designdevelopllc.com
A
B
C
D
1 2 3 4 5
© 2021 Design Develop LLC
1/4" = 1'-0"
10/5/2023 11:52:47 AM
A-101
FLOOR PLAN &
SECTIONS
Project Number
820 East Jefferson St.
Charlottesville, VA 22902
Owner
10/05/2023
AM
Checker
CUMBRE CAFE
1/4" = 1'-0"
A-101
A1 PLAN - LEVEL 1
No. Description Date
1/4" = 1'-0"
A-101
C3 SECTION E-W
1/4" = 1'-0"
A-101
A3 SECTION N-S
DN
C1
A-401
C4
A-401
2 X 8 JOISTS @ 16"
C/C ORTHOGONAL
(TYP)
(2) 2X8 ALIGNED
2X8 ALIGNED
0' - 3 1/2"
FASCIA MOUNTED
BRACKETS FOR
SAIL SHADE POSTS
PROPERTY LINE
2X10 COMPOSITE
SMOOTH TRIM
BOARD (PAINTED)
2X10 COMPOSITE
SMOOTH TRIM BOARD
(PAINTED)
2X8 COMPOSITE
SMOOTH TRIM BOARD
(PAINTED)C5
A-401
8' - 0"
8' - 0"
8' - 0"
8' - 0"
1' - 8"8' - 0"8' - 0"8' - 0"8' - 0"6' - 8"1' - 8"
C1
A-401
C4
A-401
24"Ø SONOTUBE
EMBEDED 24" (MIN)
BELOW FINISH GRADE
6#4 VERTICAL AND #3
HOOPS @ 8'
18" Ø SONOTUBE
EMBEDED 24" (MIN)
BELOW FINISH GRADE
6#4 VERTICAL AND #3
HOOPS @ 8' (TYP. UNO)
(3) 2X12
BEAM
ABU66Z (TYP.)
BRACKETS
DECK OUTLINE
PROPERTY LINE
6X6 SLEEPER
C5
A-401
3/8" / 1'-0"
C1
A-401
C4
A-401
FLOOR MOUNTED
SAIL SHADE
POSTS
FASCIA MOUNTED
SAIL SHADE POSTS
(TYP, UNO)
42" HIGH FLOOR
MOUNTED STEEL
CABLE RAILING
PROPERTY LINE
COUNTER
MOUNTED ON
BALAUSTERS OF
FLOOR MOUNTED
STEEL CABLE
RAILING
0' - 0"
-0' - 5 1/2"
0' - 0"
0' - 0"
C5
A-401
EXISTING RAILING
TO REMAIN
FINISHED FLOOR
LEVEL
0' - 0"
Roof
11' - 8"
Ceiling Lvl
8' - 0"
C4
A-401
ABU66Z (TYP.)
BRACKETS
(3) 2X12 BEAM
SAIL SHADE POSTS
FLOOR MOUNTED
BRACKET FOR SAIL
SHADE POSTS
18" Ø SONOTUBE EMBEDED 24" (MIN)
BELOW FINISH GRADE
6#4 VERTICAL AND #3 HOOPS @ 8' (TYP.
UNO)
2 X 8 JOISTS @ 16" C/C
ORTHO. (TYP)
FLOOR MOUNTED STEEL
CABLE RAILING
(2) 2X8 ALIGNED BOARDS2X10 COMPOSITE SMOOTH
TRIM BOARD (PAINTED)
FINISHED FLOOR
LEVEL
0' - 0"
Roof
11' - 8"
Ceiling Lvl
8' - 0"
C1
A-401
ABU66Z (TYP.)
BRACKETS
(3) 2X12 BEAM
SAIL SHADE POSTS
FASCIA MOUNTED BRACKET
FOR SAIL SHADE POSTS
18" Ø SONOTUBE EMBEDED
24" (MIN) BELOW FINISH
GRADE
6#4 VERTICAL AND #3
HOOPS @ 8' (TYP. UNO)
2 X 8 JOISTS @ 16" C/C
ORTHO. (TYP)
FLOOR FINISH FLOOR MOUNTED CABLE RAIL
WITH BRACKETS ON
BALUSTERS TO HOLD
COUNTER
2X10 COMPOSITE SMOOTH
TRIM BOARD (PAINTED)
2X10 COMPOSITE SMOOTH
TRIM BOARD (PAINTED)
COUNTER SUPPORTED BY
BALUSTERS OF RAILING
FLOOR MOUNTED CABLE RAIL
WITH BRACKETS TO HOLD
COUNTER
FLOOR MOUNTED
CABEL RAIL
FLOOR MOUNTED
SAIL SHADE POSTS
FASCIA MOUNTED SAIL SHADE
POSTS (TYP, UNO)
DECK FLOOR BOARD
2 X 8 JOISTS @ 16" C/C
ORTHOGONAL (TYP)
1:12 RAMP
6X6 SLEEPER ON GRADE
2X10 COMPOSITE SMOOTH TRIM
BOARD (PAINTED)
2X10 COMPOSITE SMOOTH
TRIM BOARD (PAINTED)
FASCIA MOUNTED BRACKETS TO
SUPPORT SAIL SHADE POSTS
NEW GUARD RAIL ON DECK
(3) 2X12 BEAM
ABU66Z (TYP.)
BRACKETS
18" Ø SONOTUBE EMBEDED 24"
(MIN) BELOW FINISH GRADE
6#4 VERTICAL AND #3 HOOPS @ 8'
(TYP. UNO)
24"Ø SONOTUBE EMBEDED 24"
(MIN) BELOW FINISH GRADE
6#4 VERTICAL AND #3 HOOPS @ 8'
SAIL SHADE
BASE PLATES FOR
SAIL SHADE POSTS
(2) 2X8 ALIGNED
2X8 COMPOSITE SMOOTH TRIM
BOARD (PAINTED)
EXISTING RAILING
DECK ALSO ACTS AS STEP TO
CONNECT EXISTING LANDING
TO PROPOSED NEW DECK
FINISHED FLOOR
LEVEL
0' - 0"
Roof
11' - 8"
Ceiling Lvl
8' - 0"
FASCIA MOUNTED
SAIL SHADE POSTS
(3) 2 X12 BEAM
18" Ø SONOTUBE EMBEDED 24"
(MIN) BELOW FINISH GRADE
6#4 VERTICAL AND #3 HOOPS @
8' (TYP. UNO)
ABU66Z (TYP.)
BRACKETS
SAIL SHADE
2 X 8 JOISTS @ 16" C/C
ORTHO. (TYP)
www.designdevelopllc.com
Scale
Project number
Date
Drawn by
Checked by
ARCHITECT
Design Develop, LLC
802 East Jefferson St.
Suite B3
Charlottesville, VA 22902
434.806.8365
Contact: Bob Pineo
Email: bob@designdevelopllc.com
A
B
C
D
1 2 3 4 5
© 2021 Design Develop LLC
As indicated
10/5/2023 11:52:54 AM
A-401
ENLARGED PLANS
AND SECTIONS
Project Number
820 East Jefferson St.
Charlottesville, VA 22902
Owner
10/05/2023
AM
Checker
CUMBRE CAFE
No. Description Date
1/8" = 1'-0"
A-401
A2 DECK-FRAMING PLAN
1/8" = 1'-0"
A-401
A1 GRADE
1/8" = 1'-0"
A-401
A3 PLAN - LEVEL 1
1/4" = 1'-0"
A-401
C1 SECTION 2
1/4" = 1'-0"
A-401
C4 SECTION 1
A-401
A4 Exploded Isometric
1/4" = 1'-0"
A-401
C5 SECTION 3
CONCRETE PLATFORM AT
EXISTING FINISHED FLOOR LEVEL
6X6 SLEEPER ON GRADE
2X8 COMPOSITE TRIM BOARD
(PAINTED)
DECK AT SAME LEVEL AS
FINISHED FLOOR LEVEL
www.designdevelopllc.com
Scale
Project number
Date
Drawn by
Checked by
ARCHITECT
Design Develop, LLC
802 East Jefferson St.
Suite B3
Charlottesville, VA 22902
434.806.8365
Contact: Bob Pineo
Email: bob@designdevelopllc.com
A
B
C
D
1 2 3 4 5
© 2021 Design Develop LLC
10/5/2023 11:53:07 AM
A-901
3D
REPRESENTATIONS
Project Number
820 East Jefferson St.
Charlottesville, VA 22902
Owner
10/05/2023
Author
Checker
CUMBRE CAFE
No. Description Date
A-901
1 View 3- Approach from sidewalkA-901
2 View 1- Aerial Approach
A-901
3 View 4- From Rear Sidewalk
A-901
4 View 2- Aerial Rear
A-901
5 View 5- From RoadA-901
6 View 6- From Deck- Ramp
A-901
7 View 7- From Deck A-901
8 View 8- From rear side of deck
PLANNING COMMISSION REGULAR MEETING
APPLICATION FOR A SPECIAL EXCEPTION PERMIT
APPLICATION NUMBER: PL-25-0021
DATE OF MEETING: February 11, 2025
DEPARTMENT OF NEIGHBORHOOD DEVELOPMENT SERVICES STAFF REPORT
Project Planner: Carrie Rainey
Date of Staff Report: February 4, 2025
Applicant: Piedmont Housing Alliance (PHA)
Applicant’s Representative(s): Grimm + Parker Architects
Current Property Owner: NHTE Piedmont Garrett Square Limited Partnership
Application Information
Property Street Address: 400-426 Garrett Street Friendship Court Phase 3 (“Subject Property”)
Tax Map & Parcel/Tax Status: 280112000 (real estate taxes paid current - Sec. 34-5.2.1.C.3.e)
Total Square Footage/ Acreage Site: Approx. 5.3 acres (230,870 square feet)
Comprehensive Plan (General Land Use Plan): Urban Mixed Use Node
Current Zoning Classification: CX-8 Corridor Mixed Use
Overlay District: None
Applicant’s Request (Summary)
The applicant requests a Special Exception Permit (SEP) pursuant to City Code Sections 34-
2.4.4.B.5 and 34-5.2.15, which states a SEP may be granted for physical dimensional standards,
for Phase 3 of the Friendship Court (Kindlewood) project. The applicant has requested to
modify the street-facing entry spacing requirements for 2nd Street SE and Hinton Avenue
Extended (new public street) for proposed Building 12. Per Section 34-2.10.1.B.1, 2nd Street SE
is designated as a primary street and Hinton Avenue Extended is designated as a side street.
The CX-8 Corridor Mixed Use district requires a street-facing entry every 40-ft on primary
streets and a street-facing entry every 60-ft on side streets. The subject property has street
frontage on 2
nd Street SE, Garrett Street, and Monticello Avenue, as well as the new extensions
of Hinton Avenue and 4th Street (proposed as a part of this Phase 3 project).
CITY OF CHARLOTTESVILLE
Department of Neighborhood Development Services
City Hall Post Office Box 911
Charlottesville, Virginia 22902
Telephone 434-970-3182
Fax 434-970-3359
www.charlottesville.gov
Page 2 of 8
Vicinity Map
Context Map 1
Phase 1
Phase 2
Phase 3
Phase 4
NORTH
Page 3 of 8
Context Map 2- Zoning Classifications
Context Map 3- Future Land Use Plan, 2021 Comprehensive Plan
CX-8
NX-8
RX-5
NX-10
R-A
R-C
CX-3
CV
RN-A
NX-10
NX-10
Urban Mixed Use Node
NORTH
NORTH
Higher-Intensity
Residential
General Residential
(Sensitive Community Areas)
Neighborhood
Mixed Use Corridor
General Residential
Cemetery
Medium Intensity
Residential
Page 4 of 8
Context Map 4- General Project Phasing and Areas of Impact
Standard of Review
City Council may grant an applicant a Special Exception Permit (SEP), giving consideration to a
number of factors set forth within Zoning Ordinance Section 34-5.2.15.D. If Council finds that a
proposed use or development will have potentially adverse impacts, and if Council identifies
development conditions that could satisfactorily mitigate such impacts, then Council may set
forth reasonable conditions within its SEP approval. The role of the Planning Commission is to
make an advisory recommendation to the City Council, as to (i) whether or not Council should
approve a proposed SEP and if so, (ii) whether there are any reasonable development
conditions that could mitigate potentially adverse impacts of the proposed development.
Section 34-5.2.15.D of the City’s Zoning Ordinance lists a number of factors that Council will
consider in making a decision on a proposed SEP. Following below is staff’s analysis of those
factors, based on the information provided by the applicant.
SEP Area
of Impact
NORTH
Conceptual Phase 4
12 11
10
9B
9A
Page 5 of 8
(1) Whether the proposed modifications to physical dimensional standards will be
harmonious with existing and approved patterns of development on the same or an
opposing block face or abutting property;
2nd Street SE Block
The applicant proposes increasing the 40-ft maximum street-facing entry spacing
requirement on 2nd Street SE to permit the proposed two (2) street-facing entries spaced a
maximum of 82-ft 5-in. The applicant’s narrative indicates the building width along 2nd
Street SE is 190-ft. The applicant’s narrative indicates the proposed street-facing entries on
2nd Street SE will be spaced no more than 40-ft from each end of the building façade in line
with Section 34-2.10.13.A.4.
Staff Analysis: The entire eastern side of the 2nd Street SE block is part of the Friendship
Court property and proposed for redevelopment, including Phase 3 (current application)
and a future Phase 4 (no application has been made at the filing of this report). The western
side of the block is comprised two (2) large buildings which are generally setback 12-ft to
30-ft from the property line. The northwestern building has 2 entries spaced approximately
50-ft from each other along a façade of approximately 150-ft. The southwestern building
has 3 entries spaced approximately 25-ft from each other along a façade of approximately
160-ft. Staff believes some existing entries do not meet the requirements of street-facing
entries as they lack an entry feature per Section 34-2.10.13.B. The yards of the western
properties are landscaped.
Proposed Building 12 will provide a similar setback to the 12-ft existing minimum building
setback on the western side of the block, as well as two (2) street-facing entries with entry
features and foundation landscaping as described in the applicant’s narrative and exhibits.
While these entries are spaced further apart than existing entries in the block, staff believes
the street activation generated by these entries, which will otherwise meet the
requirements and intent of Section 34-2.10.13, is harmonious with the existing patterns of
development within the block.
Hinton Avenue Extended Block
The applicant proposes eliminating street-facing entry requirements on Hinton Avenue
Extended. The applicant’s exhibits indicate the building width along Hinton Avenue
Extended is 66-ft 6-in. Section 34-2.10.13.A.3.e. states a street-facing entry is required on
side street frontages when the building width is more than the required maximum spacing
(60-ft).
Page 6 of 8
Staff Analysis: Hinton Avenue Extended is a new public street proposed as part of the Phase
3 project and fronted by two (2) buildings (Buildings 10 and 12) and a public park along the
southern side of the block. Building 10 is approximately 45-ft wide with two (2) street-facing
entries along Hinton Avenue Extended. The northern side of the block is proposed to be
redeveloped in the futures as Phase 4 to the project. The existing buildings within the future
Phase 4 area are oriented to an interior courtyard with the rear of the residential units
facing the location of the new Hinton Avenue Extended section. The existing buildings
immediately across from Building 12 does include rear doors. However, the existing
buildings within the Phase 4 area are proposed to be removed as a part of the Phase 3
project and staff does not believe the existing rear doors meet the street-facing entry
requirements. Staff finds the proposed removal of the street-facing entry on Hinton Avenue
harmonious with the existing patterns of development.
(2) Whether the proposed modification supports the goals and strategies of the
Comprehensive Plan;
Below are specific areas of the Comprehensive Plan for which the development is in
compliance:
a. Land Use, Urban Form, and Historic & Cultural Preservation
Future Land Use Planning Objectives: Protect, preserve, and enhance natural
and cultural resources.
Objectives for Mixed-Use Areas: Encourage compact block and street networks
and a built environment that facilitates walking, biking, and bus riding.
Objectives for Mixed-Use Areas: Develop buildings and public spaces that are
human-scaled and contribute to placemaking & Charlottesville’s authentic
community identity.
Strategy 2.1 Through City-led efforts and private development, expand
community access to housing, as well as amenities and services that improve
quality of life.
b. Environment, Climate, and Food Equity
Strategy 6.1 Monitor, protect, and expand the urban tree canopy cover both at
citywide and neighborhood levels.
Comprehensive Plan- Staff Analysis:
The Future Land Use Plan of the 2021 Comprehensive Plan designates the subject property
and surrounding properties as Urban Mixed Use Node, which is defined as urban mixed use
districts that support community housing, employment, and commercial development. The
form specified for Urban Mixed Use Node areas is … new, complete districts comprised of a
walkable grid of streets, civic amenity spaces, and an intensive mix of land uses.
The
Page 7 of 8
Friendship Court project, through all phases, expands affordable housing options in the
community. Phase 3 provides 87 affordable residential units. However, the Virginia Housing
funding requirements for this project include equity of units and features, which prohibits
entry spacing meeting the maximum allowance for 2nd Street SE and Hinton Avenue
Extended as required entries would provide direct access to some units.
The project does create a new public street network within the development, breaking
down the large block into several smaller blocks and providing access to the new public park
created as a part of this project (Phases 2 and 3). Several goals in the Comprehensive Plan
speak to a desire for appropriately scaled redevelopment and compact street networks that
contribute to placemaking, improve the pedestrian experience, and connect residents with
amenities and destinations. The project adds new public streets including Hinton Avenue
Extended to the network, connecting residents and visitors to the new public park and
nearby destinations such as the Downtown Mall.
The applicant’s narrative states the 2
nd Street SE frontage along Building 12 will have
additional elements to promote street activation and contribute to placemaking including
seating nodes setback from the sidewalk with foundation plantings. The Comprehensive
Plan also prioritizes the preservation and consideration of streetscape trees and urban tree
canopy. The proposed reduction in street-facing entries limits impacts to the root zone of
white oak streetscape trees along 2nd Street SE, which provide mature tree canopy and
improve the pedestrian experience. Staff finds the proposed modification supports the
goals and strategies of the Comprehensive Plan.
The width of Building 12 along Hinton Avenue Extended (66-ft 6-in.) is slightly wider than
the 60-ft minimum building width required to provide a side street-facing entry per Section
34-2.10.13.A.3.e. However, the building width is still at a pedestrian scale well below the
maximum allowed building width of 275-ft per Section 34-2.4.4.B.2. In addition, entries are
provided within 40-ft of the Hinton Avenue Extended façade on each adjoining building
façade. These entries will generally be visible from Hinton Avenue Extended and contribute
to the activation of Hinton Avenue Extended.
(3) Whether, with conditions, the Special Exception Permit is consistent with the public
necessity, convenience, general welfare, and good zoning practice.
As the application aligns with the Comprehensive Plan, provides amenities such as outdoor
spaces to otherwise activate the street and meet the intent of the street-facing entry
requirements per Section 34-2.10.13.A.1, as well as protects existing mature streetscape
trees which contribute to urban tree canopy and improve the pedestrian experience, staff
Page 8 of 8
finds granting the Special Exception Permit is consistent with good zoning practice and
general public welfare.
Public Comments Received
Staff has received no public comments at the publishing of this report.
Staff Recommendation
Staff recommends the Planning Commission recommend approval of the Special Exception
Permit to modify the street-facing entry requirements for Building 12, identified in the
application exhibits dated January 28, 2025, to require no street-facing entry spacing
maximums on the 2nd Street SE and Hinton Avenue Extended building façades.
Recommended Conditions
Staff recommends two (2) street-facing entries on 2nd Street SE meeting the requirements of
34-2.10.13.B are required as a condition of this Special Exception Permit.
Suggested Motions
1. I move to recommend approval of this application for a Special Exception Permit in the
CX-8 Corridor Mixed Use zone at 400-426 Garrett Street to modify street-facing entry
requirements for Building 12, identified on the application materials dated January 28,
2025, to require no street-facing entry spacing maximums on the 2nd Street SE and
Hinton Avenue Extended building façades with the following condition:
a. At least two (2) street-facing entries with entry features meeting the
requirements of Section 34-2.10.13.B are required on the 2
nd Street SE building
façade of proposed Building 12.
b. [condition(s) proposed by Planning Commission]
OR,
2. I move to recommend denial of this application for a Special Exception Permit in the CX-
8 Corridor Mixed Use zone at 400-426 Garrett Street to modify street-facing entry
requirements for Building 12, identified on the application materials dated January 28,
2025.
Attachments
A. Special Exception Permit Narrative dated January 28, 2025
B. Special Exception Permit Exhibits dated January 28, 2025
123 East Main Street, 2nd Floor | Charlottesville, VA 22902 | 434.296.5353 | grimmandparker.com
CALVERTON, MD | TYSONS, VA | CHARLOTTESVILLE, VA
January 28, 2025
ATTN: Carrie Rainey
Charlottesville Neighborhood Development Services
Friendship Court Redevelopment Phase 3 – Special Exception Permit
Dear Ms. Rainey,
This letter is to request a Special Exception Permit to Division 2.10.13 Rules for Zoning Districts: Street-
Facing Entry Spacing.
Zoning Ordinance Special Exception
Per the CX-8 zoning district requirements, entrances must be spaced a maximum of every 40’ along
Primary Streets and 60’ along Side Streets. The entrances aim to provide visual interest along the public
realm, and promote greater use and activation of the public sidewalk.
We are requesting a special exception permit for Building 12, bordered by 2nd Street SE (primary) and a
new side street, currently designated as Hinton Ave Ext. on the Friendship Court Phase 3 site plan
submission. Per the CX-8 requirements, 2nd Street would need 4 total street-facing entries, and Hinton
Ave would require 1 street-facing entry.
Special Exception Reasoning
Building 12 is a multi-family residential building with amenity space and parking on the lowest floor. The
ground story as defined by Section 2.10.1.F along 2nd St SE shifts between the lowest and second levels
(as demonstrated by Modules 1 and 2 on the attached exhibit) due to grades. The ground story along 2nd
Street has residential units for 122’ of the total 190’ building length, and for the entirety of Hinton Ave.
Ext. If we were to provide all of the required street-facing entrances, three of the required entrances
would have direct access to residential units. All units in this building enter off an interior corridor.
Adding the street-facing entries directly into individual units creates a security concern for property
management, who needs to be able to monitor building access through a limited number of entrances.
Currently our main pedestrian entrance is located on the corner of 2nd St SE and Monticello Ave, and the
main vehicular garage entrance is located off the rear alley.
Many of the units in Building 12 accommodate larger families with children or special needs
dependents. Direct exterior unit access along busier streets like 2nd St SE and Monticello Ave. creates
concern among residents about a child or dependent getting outside without proper supervision.
The ground story along Hinton Ave Ext is fully occupied by two 2-bedroom residential units. Any
entrance on this elevation would go directly into those units, creating an undesirable and unacceptable
security risk for residents and management.
123 East Main Street, 2nd Floor | Charlottesville, VA 22902 | 434.296.5353 | grimmandparker.com
CALVERTON, MD | TYSONS, VA | CHARLOTTESVILLE, VA
This project is being financed through Virginia Housing, which requires equity of unit features among all
unit types within a single building. Providing an entrance in only a few units creates major discrepancies
in the floorplan features available to the residents.
Finally, and importantly, one of the major goals of this project and the city is to maintain the health and
longevity of the street trees along 2nd St SE. Reducing entrances and any related exterior construction
will minimize impacts on the extensive root structure of these trees.
Proposed Solution
Our proposed solution provides two entrances along 2nd St SE and no entrances along Hinton Ave. Ext.
The two 2nd St SE entrances would access the main building lobby and egress stair, respectively. These
will be spaced within 40’ of each end of the building. As shown in diagram K9 on sheet A010, the ground
story transitions from the 1st to 2nd floor between these two doors to meet the grade change along 2nd St
SE. The exterior landing and stairs required to reach additional entrances would encroach upon the
public access easement (if run is perpendicular to the building) or pass in front of an adjacent unit (if run
is parallel to the building), interrupting planned locations for glazing.
The Building 12 streetscape design will include features that promote visual interest in the public realm,
and maintain walkability and public safety. These features may include building mounted decorative
screening, hardscape features, and specialized plantings. We will design to the principles of the zoning
ordinance, particularly Section 2.10.12.B.3 Blank Wall Treatments. Preservation of the existing large
street trees is a major component of our proposed solution. They will provide shading of the pedestrian
way from Day 1, and continue to enhance the walk along this pivotal access artery between downtown
and IX Art Park. Foundation planting along the building frontage will frame seating nodes set back from
the sidewalk. These areas will enhance the pedestrian experience and break up the building façade to
compensate for the removed entrances.
Glazing strategies will be used at the residential levels, which take up the majority of the ground story.
The building transparency ratio is designed to exceed the zoning requirement, enhancing visual
connection from the street to the active depth.
The building is in an early design phase and significant stakeholder engagement is still required, but the
design and development team will preserve the city’s vision for an engaging public way throughout the
design process.
DN
DN
DN
2ND STREET SE
(PRIMARY STREET)
MONTICELLO AVENUE
(PRIMARY STREET)
GARRETT STREET
(PRIMARY STREET)
HINTON AVE EXT.
(SIDE STREET)
4TH ST SE EXT.
(SIDE STREET)
BUILDING 13
N.I.C.
BUILDING 9
MODULE 1
BUILDING 10
MODULE 1
BUILDING 11
BUILDING 12
MODULE 1
PARK
(TREATED SIM. TO
SIDE STREET)
BUILDING 12
MODULE 2
BUILDING 12
MODULE 3
D1: BUILD-TO10' - 0"
(B1; H1-LOT) 125' - 1 31/64"
(B3; H3-LOT) 137' - 1 21/32"
(H3-BLDG) 111' - 2"
(B4; I1-LOT) 222' - 9 57/64"
(I1-BLDG 12) 66' - 7 1/8"
(I1-BLDG 10) 45' - 2"
(B5; I2-LOT) 215' - 11 41/128"
(I2-BLDG 9A) 45' - 2"
(I2-BLDG 9B) 119' - 9"
(B2) 207' - 7 205/256"
LOT 3A
A1: 55,032 SF
2.1: 72 UNITS
3.1: 44% COVERAGE
LOT 3D
A4; C: 19,168 SF
2.4: 0 UNITS
3.4: 0% COVERAGE
LOT 3B
A2: 28,160 SF
2.2: 10 UNITS
3.2: 18% COVERAGE
M3 LOW POINT: 430'
M3 HIGH POINT: 434.15'
M2 HIGH
POINT: 435.6'
M2 LOW POINT: 432'AVG. GRADE: 433.8'
AVG. GRADE: 432.1'
M1 HIGH POINT: 442.1'
M1 LOW POINT: 432.9'
AVG. GRADE: 437.5
M4 HIGH POINT: 437.1'
M1 LOW POINT: 433'
BUILDING 10
MODULE 2
BUILDING 10
MODULE 3
BUILDING 10
MODULE 4
BUILDING 9
MODULE 2
M2 LOW
POINT: 435
M2 HIGH
POINT: 438.5
AVG. GRADE: 436.75
AVG. GRADE: 437.55
M1 LOW POINT: 436
M1 HIGH POINT: 439.1
M1 HIGH POINT: 434.1'
M2 HIGH POINT: 435.1'
M3 LOW POINT: 435.9'
M2 LOW POINT: 434.9'
M3 HIGH POINT: 436.1'
M4 LOW POINT: 434.9'
LOTS 3C-1 TO 3C-6
A3: LOT AREA: 1,160 TO 1,393 SF EACH
GROUND FLOOR AREA: 800 SF EACH
2.3: 1 UNIT EACH; 6 UNITS TOTAL
3.3: 57 TO 69% COVERAGE (VARIES)
BUILDING 12 TOTAL
GROUND FLOOR AREA
17,329 SF
GROUND FLOOR AREA
3,036 SF
BUILDING 10 TOTAL
GROUND FLOOR AREA
3,702 SF
BUILDING 9 TOTAL
GROUND FLOOR AREA
5,091 SF
E1: BUILD-TO
10' - 0"
D3: BUILD-TO
10' - 0"
E2: BUILD-TO
10' - 0"
E2: BUILD-TO
10' - 0"
ADJACENT LOTS ACROSS
MONTICELLO AVE
RX-5 & NX-8
ADJACENT LOTS ACROSS
2ND ST SE
ZONED NX-10
ADJACENT LOT ACROSS
HINTON AVE EXT.
& 4TH ST SE EXT.
(FUTURE PHASE 4)
ZONED CX-8
ADJACENT LOTS ACROSS
GARRETT ST
ZONED NX-10
ADJACENT LOT ACROSS
4TH ST SE EXT.
(PLANNED PHASE 2)
ZONED CX-8
ADJACENT LOT ACROSS
PRIVATE ALLEY
(PHASE A)
ZONED CX-8
D2: BUILD-TO
10' - 0"
STREET TREE
PROTECTION
EASEMENT
66' - 0 1/2"
23' - 7 7/16"
24' - 0 1/2"
49' - 0 237/256"
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
53' - 6 3/4"
A011
E16
A011
H11
M3 GROUND STORY
BLDG 12 - LEVEL 6
430' - 0"
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
53' - 6 3/4"
M2 GROUND STORY
M1 GROUND STORY
10' - 9 7/8"12' - 0"
6' - 0"
A011
H15
A011
H18
39' - 11 5/8"
STREET FACING ENTRY
SPACING AS INDICATED IN
ZONING ORDINANCE.
ISOLATED ENTRIES NOT
FEASIBLE PER BUILDING
PROGRAM.
SEE ATTACHED LETTER.
BLDG 12 - LEVEL 6
430' - 0"
39' - 0"
REQ. 40'-0" MAX TO CORNER
27' - 0"
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
53' - 6 3/4"
M1 GROUND STORY
STREET FACING ENTRY SPACING
AS INDICATED IN ZONING
ORDINANCE. ISOLATED ENTRIES
NOT FEASIBLE PER BUILDING
PROGRAM.
SEE ATTACHED LETTER.
BLDG 12 - LEVEL 6
430' - 0"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
REQUIRED 60'-0" MAXIMUM
35' - 7"
A011
A16
M4 GROUND STORY
GROUND STORY
ELEVATION SHOWING
INTENDED COMPLIANCE
WITH 30% TRANSPARENCY.
FINAL ELEVATION DESIGN
IS INCOMPLETE.
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
M1 GROUND STORY
M2 GROUND STORY
M3 GROUND STORY M4 GROUND STORY
A011
A11 SIM
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
BLDG 12 - TRUSS
BEARING
484' - 8 141/256"
GROUND STORY
A011
A11 SIM.
BLDG 12 - LEVEL 6
430' - 0"
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
A011
A11
14' - 0 1/2" TYP.
M2 GROUND STORY
M1 GROUND STORY
BLDG 12 - LEVEL 6
430' - 0"
BUILDING 12 -
GARAGE LEVEL
431' - 1 205/256"
BLDG 12 - LEVEL 1
443' - 1 205/256"
BLDG 12 - LEVEL 2
453' - 11 173/256"
BLDG 12 - LEVEL 3
464' - 9 141/256"
BLDG 12 - LEVEL 4
475' - 7 109/256"
REQUIRED 60'-0" MAXIMUM
35' - 3"
M1 GROUND STORY
GROUND STORY
ELEVATION SHOWING
INTENDED COMPLIANCE
WITH 30% TRANSPARENCY.
FINAL ELEVATION DESIGN
IS INCOMPLETE.
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
www.grimmandparker.com
123 East Main St, 2nd Floor
Charlottesville, VA 22902
Tel: 434.465.6680
A010 ZONING CODE STUDY
FRIENDSHIP COURT REDEVELOPMENT PHASE 3
CHARLOTTESVILLE, VA
01/28/2025
SPECIAL EXCEPTION PERMIT
GP #22229.00
NTSA11 SITE PLAN DIAGRAM
1/16" = 1'-0"K17 BUILDING 12 - MONTICELLO AVE
1/16" = 1'-0"K9 BUILDING 12 - 2ND STREET
1/16" = 1'-0"K4 BUILDING 12 - HINTON AVE
1/16" = 1'-0"G14 BUILDING 10 - HINTON AVE
1/16" = 1'-0"G10 BUILDING 10 - PARK
1/16" = 1'-0"G17 BUILDING 11 - PARK
1/16" = 1'-0"G4 BUILDING 09 - GARRETT STREET
1/16" = 1'-0"G7 BUILDING 09 - 4TH ST SE EXT.
CX-8 ZONING CALCULATIONS
GENERAL NOTE: BOLD / ITALICIZED ITEMS ARE NOT IN COMPLIANCE.
PLANNED FUTURE REQUESTS FOR DEPARTURE FROM BY-RIGHT ZONING
ARE NOTED.
A. LOT (REFER TO DETAIL A11/A010 FOR SUPPORTING INFORMATION)
1. LOT SIZE
AREA REQUIRED: NO MINIMUM
AREA PROVIDED:
A.1. LOT 3A: 55,032 SF
A.2. LOT 3B: 28,160 SF
A.3. LOTS 3C-1 TO 3C-6: N.I.C. SEE CIVIL
A.4. LOT 3D: 19,168 SF
A.5. TOTAL LOT AREA FOR PHASE 3: 109,799 SF (EXCLUDES R/W)
FRONT ACCESS WIDTH REQUIRED: 40' MIN.
FRONT ACCESS WIDTH PROVIDED:
B1. MONTICELLO AVE: 125'
B2. 2ND ST SE: 207'
B3. GARRETT ST: 137'
SIDE/REAR ACCESS WIDTH REQUIRED: 15' MIN
SIDE/REAR ACCESS WITH PROVIDED:
B4. HINTON AVE EXT.: 222'
B5. 4TH STREET EXT.: 215'
2. DENSITY
DWELLINGS PER LOT REQUIRED: UNLIMITED
DWELLINGS PER LOT PROVIDED:
2.1. LOT 3A (BLDGS 10, 11, 12): 72 UNITS
2.2. LOT 3B (BLDG 9): 16 UNITS
2.3. LOTS 3C-1 TO 3C-6: (BLDG 9B): 1 UNIT EACH
2.4. LOT 3D (PARK): NO UNITS
3. COVERAGE
BUILDING COVERAGE REQUIRED: NO MAXIMUM BUILDING COVERAGE
BUILDING COVERAGE PROVIDED:
3.1. LOT 3A (BLDGS 10, 11, 12): 44%
3.2. LOT 3B (BLDG 9): 18%
3.3 LOTS 3C-1 TO 3C-6 (BLDG 13): 57 TO 69% (VARIES)
3.3. LOT 3D (PARK): 0%
OUTDOOR AMENITY SPACE REQUIRED: 109,799 SF * 10% = 10,978 SF
OUTDOOR AMENITY SPACE PROVIDED:
C. 19,168 SF (LOT 3D IS ALL OPEN SPACE; ALSO SEE 2.10.4
ZONING DETERMINATION LETTER ON SHEET A011)
4. BUILDING SETBACKS
PRIMARY AND SIDE STREET LOT LINE REQUIRED: 0' TO 10' MAXIMUM
PRIMARY STREET LOT LINE SETBACK PROVIDED:
D1. MONTICELLO AVENUE: 10' MAXIMUM
D2. 2ND ST SE: 10' MAXIMUM
D3. GARRETT STREET: 8'-6" MAXIMUM
SIDE STREET LOT LINE REQUIRED: 0' TO 10' MAXIMUM
SIDE STREET LOT LINE SETBACK PROVIDED:
E1. HINTON AVE EXT.:10' MAXIMUM
E2. 4TH ST SE EXT.:10' MAXIMUM
5. BUILD-TO
PRIMARY STREET REQUIRED: 75%
PRIMARY STREET PROVIDED:
H1. MONTICELLO AVE: 109.8' / 125.1' = 88%
H2. 2ND ST SE: 162.75' / 207.75' = 78%
H3. GARRETT ST: 111' / 137' = 81%
SIDE STREET REQUIRED: 45%
SIDE STREET PROVIDED:
I1. HINTON AVE EXT.: (66.5' + 45.2) / 222.8' = 50%
I2. 4TH ST. EXT.: (119.8' + 45.2) / 215.9' = 76%
6. TRANSITION
6.1: TO RX-5 ZONE: NONE REQUIRED
6.2: TO NX-8 ZONE: NONE REQUIRED
6.3: TO NX-10 ZONE: NONE REQUIRED
7. PARKING LOCATION: ALL ON-SITE PARKING IS LOCATED INTERNALLY
TO OR AT THE SIDE / READ YARD OF THE LOT IT SERVES. SEE CIVIL
DRAWINGS FOR ON-SITE PARKING LOCATIONS AND 12-A101 FOR
GARAGE PARKING INFORMATION.
B. BUILDINGS (REFER TO DETAILS G4 THROUGH K17 ON SHEET A010 FOR
SUPPORTING INFORMATION)
1. HEIGHT
BUILDING HIEGHT MAXIMUM: 8 STORIES, 114'
BUILDING HEIGHT PROVIDED: (NOTED HEIGHTS ARE APPROX., FINAL
HEIGHTS WILL BE DOCUMENTED IN THE BUILDING PERMIT SUBMISSION)
A1. BUILDING 9: 4 STORIES, 48.06' MAX
A2. BUILDING 13: 3 STORIES ASSUMED, N.I.C.
A3. BUILDING 10: 4 STORIES, 48.06' MAX
A4. BUILDING 11: 4 STORIES, 48.06' MAX
A5. BUILDING 12: 5 STORIES, 68.56' MAX
2. MASSING
BUILDING WIDTH MAXIMUM: 275'
BUILDING WIDTH PROVIDED (APPROX):
C1. BUILDING 9: 45' x 111'
C2. BUILDING 13: 40' x 120' ASSUMED, N.I.C.
C2. BUILDING 10: 45' x 89'
C3. BUILDING 11: 39' X 67'
C4. BUILDING 12: 66' X 112' (MODULE 3), 66' X 192' (MODULES 1 & 2)
ACTIVE DEPTH: COMPLIANCE WILL BE DEMONSTRATED IN BUILDING
PERMIT SUBMISSION.
3. GROUND STORY
GROUND STORY RESIDENTIAL HEIGHT REQUIRED: 10' MIN.
GROUND STORY RESIDENTIAL HEIGHT PROVIDED:
F1. BUILDING 9: 10'-7"
F2. BUILDING 13: UNKNOWN, N.I.C.
F2. BUILDING 10: 10'-7"
F3. BUILDING 11: 10'-7"
F4. BUILDING 12: 10'-9" (MODULE 1) & 12' (MODULES 2 & 3)
RESIDENTIAL FINISHED FLOOR ELEVATION REQUIRED: 0' MIN., 6' MAX.
RESIDENTIAL FINISHED FLOOR ELEVATION PROVIDED:
1. BUILDING 9: (PLANNED VARIANCE REQUEST TO CALCULATE
AVERAGE GRADE FROM STREET FRONTAGE ONLY -
STEEP SLOPE OCCURS AT REAR FOR BASEMENT EXIT TO
PARKING)
M1: +5.5'
M2: +4.8'
2. BUILDING 10:
M1: +1.35'
M2: +0.9
M3: +0.9
M4: +1.9'
3. BUILDING 11: +3.0'
4. BUILDING 12:
M1: +4.6'
M2: +0.35'
M3: -1.0' (PLANNED VARIANCE REQUEST)
4. TRANSPARENCY
GROUND STORY RESIDENTIAL MINIMUM: 35% PRIMARY ST., 30% SIDE ST.
GROUND STORY RESIDENTIAL PROVIDED :
BUILDING 9:
M1: 102.39(TRANSPARENCY) / 289.86(TOTAL) = 35%
M2: GARRETT: 156.78 / 432.8 = 36% 4TH: 88.26 / 293.72 = 30%
BUILDING 10: 88.26 / 293.72 = 30%
BUILDING 12:
M1: HINTON: 192 / 427.1= 44% 2ND: 389.94 / 797.74 = 48%
M2: 213.71 / 462.11 = 46%
M3: 343.82 / 713.81 = 48%
UPPER STORY TRANSPARENCY COMPLIANCE TO BE DEMONSTRATED WITH
BUILDING PERMIT SUBMISSION.
5. ENTRANCES
PRIMARY STREET ENTRY SPACING REQUIRED: 40' MAX.
PRIMARY STREET ENTRY SPACING PROVIDED:
BUILDING 9: 14'-0" MAX
BUILDING 12:
MONTICELLO AVE: 37' MAX
2ND ST: 82'-5" MAX (PLANNED SPECIAL EXEPTION PERMIT
DUE TO SECURITY CONCERNS BY BUILDING
MANAGEMENT AND VIRGINIA HOUSING)
SIDE STREET REQUIRED: 60' MAX.
SIDE STREET PROVIDED:
BUILDING 9: 34'-9" (4TH ST EXT.)
BUILDING 10: 35'-7" (HINTON AVE)
BUILDING 11: N/A
BUILDING 12:
HINTON AVE EXT.: 66'-6" (PLANNED SPECIAL EXEPTION
PERMIT DUE TO SECURITY CONCERNS BY BUILDING
MANAGEMENT AND VIRGINIA HOUSING)
6. FENCES AND WALLS: REFERENCE CIVIL DRAWINGS
GRADE PLANE AT
BUILDING FACEGRADE PLANE AT
BUILDING FACE
GRADE PLANE AT
BUILDING FACE
GRADE PLANE GRADE PLANE GRADE PLANE
GRADE PLANE
GRADE PLANE AT
BUILDING FACE
DATE SUBMISSION / REVISION #
9' - 0"
12.9
###
ENTRANCE CANOPY WITH
ADDRESS SIGNAGE
123456789101112131415161718
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER ARCHITECTURE, INC.
© GRIMM AND PARKER ARCHITECTURE, INC.
www.grimmandparker.com
123 East Main St, 2nd Floor
Charlottesville, VA 22902
Tel: 434.465.6680
A011 ZONING CODE STUDY
FRIENDSHIP COURT REDEVELOPMENT PHASE 3
CHARLOTTESVILLE, VA
04/25/2024
SITE PLAN SUBMISSION
GP #22229.00
DATE SUBMISSION / REVISION #
2.10.4 OUTDOOR AMENITY
ZONING DETERMINATION
1/4" = 1'-0"A16 BUILDING 9A/10- ENTRY A
1/4" = 1'-0"E16 BUILDING 12 - ENTRY D
1/4" = 1'-0"H18 BUILDING 12 - ENTRY A
1/4" = 1'-0"A11 BUILDING 9A - ENTRY B
1/4" = 1'-0"H15 BUILDING 12 - ENTRY B
2.10.13 ENTRANCES
CHARTS
1/4" = 1'-0"H11 BUILDING 12 - ENTRY C
RAISED ENTRANCE DIRECTLY
TO UNIT.
PRE-FABRICATED METAL
CANOPY AT EACH ENTRANCE.
MINIMUM SIZE 6'-0" X 3'-0"
MAIN BUILDING ENTRANCE.
CUSTOM METAL CANOPY
WITH BUILDING ADDRESS
SIGNAGE AND LIGHTING.
MINIMUM SIZE 12'-0" X 5'-0".
RAISED ENTRANCE TO
ERGRSS STAIR. PRE-
FABRICATED METAL CANOPY.
MINIMUM SIZE 8'-0" X 3'-0".
RAISED ENTRANCE DIRECTLY
TO UNIT.
PRE-FABRICATED METAL
CANOPY AT EACH ENTRANCE.
MINIMUM SIZE 6'-0" X 3'-0"
COVERED ENTRANCE TO
RESIDENT AMENITY SPACE.
PRE-FABRICATED METAL
CANOPY. MINIMUM SIZE 6'-0" X
3'-0"
COVERED ENTRANCE TO
RESIDENT AMENITY SPACE.
PRE-FABRICATED METAL
CANOPY. MINIMUM SIZE 6'-0" X
3'-0"
PRECEDENT IMAGE FOR 2ND STREET SE PEDESTRIAN EXPERIENCE.
PRECEDENT IMAGE BUILDING 12 MAIN ENTRANCE AT 2ND ST SE & MONTICELLO AVE.
01/28/2025
SPECIAL EXCEPTION
PERMIT
Source: City of Charlottesville website. First collected Nov 15, 2026.