City Council Work Session and Regular Meeting — Agenda Packet
City of Lynchburg · Lynchburg City County · City Council · meeting of Apr 27, 2021 · Agenda packets
Open the original document More from City of Lynchburg
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
April 27, 2021
1
GENERAL POLICY REGARDING PUBLIC PARTICIPATION AT CITY COUNCIL MEETINGS
Each speaker shall clearly state his or her name and locality of residence.
The City Council agenda is divided into four sections.
CONSENT AGENDA: This section includes routine items. All items may be approved by one vote.
PUBLIC HEARINGS: This section includes all public hearings as required by law or as Council may direct.
Procedure:
• Staff will make a presentation.
• For zoning petitions, the applicant or his or her representative shall have ten (10) minutes to make a presentation.
• Comments will then be solicited from those in favor.
• Comments will then be solicited from those in opposition.
During the public hearing, there shall be a time limit of three (3) minutes for each individual speaker. If the speaker represents a
group, there shall be a time limit of five (5) minutes. A speaker representing a group shall identify that group at the beginning of
his or her remarks. A group may have only one spokesperson. After public comments have been received, for zoning petitions,
the applicant or the representative of the applicant, at his or her discretion, may respond with a rebuttal. There shall be a five (5)-
minute time limit for rebuttal. Upon the conclusion of public comments or the applicant’s rebuttal, the public hearing will be closed
and the matter referred to Council for deliberation.
PUBLIC COMMENT: Public comment shall be for the purpose of allowing members of the public to present any matter, which, in
their opinion, deserves the attention of the Council. They shall not serve as a forum for debate with the Council. Individuals may
speak up to three (3) minutes; or group spokesperson up to five (5) minutes. Once Council has heard a presentation from a
citizen or organization on a particular subject, the citizen or organization may not make another presentation on the same subject
within three (3) months of the first presentation, except by a majority vote of the members of Council present and voting.
GENERAL BUSINESS: This section includes items of a general nature to be considered by Council.
City Council may make exceptions to these rules at its discretion. Prior to a meeting, any questions which citizens may have
regarding any item on the agenda may be addressed to City Council or the City Administration. The following numbers are
provided for the convenience of the citizens:
CITY COUNCIL 455-3995 MAYOR 455-3995 CITY MANAGER 455-3990
A reasonable charge may be made for copying and other activities related to responding to long and involved inquiries.
CITIZENS OFTEN EXPRESS CONFLICTING AND DIVERSE POSITIONS REGARDING SPECIFIC ISSUES UNDER
CONSIDERATION. TO ENCOURAGE CITIZEN PARTICIPATION AND TO AVOID INTIMIDATION TO PERSONS WHO MAY
EXPRESS SOMETIMES UNPOPULAR OPINIONS, APPLAUSE, CHEERS, OR JEERS FROM THE AUDIENCE ARE NOT
PERMITTED. WHEN APPEARING BEFORE CITY COUNCIL, CITIZENS MAY NOT ENGAGE IN BEHAVIOR THAT
INTIMIDATES OR INSULTS OTHERS, ENGAGE IN DISRUPTIVE BEHAVIOR, USE PROFANITY OR VULGAR LANGUAGE,
PROMOTE PRIVATE BUSINESS VENTURES OR CAMPAIGN FOR PUBLIC OFFICE.
* PREVIOUSLY DISCUSSED AND/OR CONSIDERED BY CITY COUNCIL
Finance Committee Meeting – CANCELED
A G E N D A
City Council Meeting of April 27, 2021
Council Chamber | City Hall, 900 Church Street, Lynchburg, VA 24504
4:00 P.M.
WORK SESSION
#1. Continue Council Budget Balancing
#2. Consideration of introducing a resolution allowing the distribution of the Chesapeake Stormwater
Network Best Urban BMP in the Bay “Small But Mighty” monetary award.
#R-21-___
#3. Roll Call
7:30 P.M.
City Council Agenda Items
COUNCILMEMBER TWEEDY WILL GIVE THE INVOCATION
April 27, 2021
2
R E C O G N I T I O N
❖ Music Week Proclamation (May 2 – May 9)
❖ Drinking Water Week Proclamation (May 2 – May 8)
C O N S E N T A G E N D A
#4. Consideration of approving the minutes from the March 23, 2021 meeting.
*#5. Consideration of adopting Resolution #R-21-025 amending the FY 2021 Operating and Capital
Budgets and appropriating or rescinding funds to reflect the FY 2021 Third Quarter Detail by Fund in
Attachment A.
P U B L I C H E A R I N G
#6. Consideration of adopting a resolution granting an easement for the extension of electric service to a
new Milestone Cell Tower.
#R-21-___
#7. Consideration of adopting a resolution granting an easement for the extension of electric service to a
new gymnasium.
#R-21-___
P U B L I C C O M M E N T S
#8. Hear from a citizen regarding a concern. (Brandon Barney)
G E N E R A L B U S I N E S S
#9. Consideration of adopting an ordinance amending §17-22 of the City Code to allow electrically charged
security fences in non-residential areas.
#O-21-___
*#10. Consideration of adopting Resolution #R-21-024 regarding Substantial Amendment #3 for the CDBG
program and the receipt of the Community Development Block Grant Coronavirus Aid, Relief and
Economic Security Act (CARES ACT) (CDBG-CV) Round 3 Program Funds.
#11. Consideration of introducing a resolution amending the FY 2021 School Capital Projects Fund budget
and appropriate $317,000 with resources from Lynchburg City Schools CARES funds for the
installation of an intercom system at E. C. Glass.
#R-21-___
#12. Consideration of adopting an ordinance amending §36-175 of the City Code to increase the gross
combined income of the owner eligible for real estate tax relief and cap the amount of relief per
applicant.
#O-21-___
#13. Consideration of a closed meeting for consultation with legal counsel regarding a legal matter requiring
the provision of legal advice, specifically legal matters relating to the collective bargaining laws that will
become effective on May 1, 2021; and to discuss the appointment of members to the following boards
or commissions: Martin Luther King, Jr./Lynchburg Community Council, Airport Commission, City
Employee Appeals Board, Transit Company Board of Directs, pursuant to Section 2.2-3711(A.)(7.) and
Section 2.2-3711(A.)(1) of the Code of Virginia, as amended.
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 2
CONSENT: REGULAR: WORK SESSION: X CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: Distribution of Chesapeake Stormwater Network Best Urban BMP in the Bay “Small But
Mighty” Monetary Award
KEY ELEMENTS:
___Economic Development _X_Excellent Government _X_Natural and Built Environment ___Safe Community _X_Vibrant Community
RECOMMENDATION: Adopt a resolution to allow the Chesapeake Stormwater Network to distribute the
monetary award on behalf of the City of Lynchburg’s Department of Water Resources as follows: $1,000 to
Camp Kum-Ba-Yah, $1,000 to the James River Association, and $1,000 to Claytor Nature Center to provide
Lynchburg youth with financial support to attend environmental education summer camps.
SUMMARY: Lynchburg Water Resources (LWR) was nominated for and won a Best Urban BMP in the Bay-
“Small, but Mighty” Award from the Chesapeake Stormwater Network (CSN) for Lynchburg Water Resource’s
“Water Wonders” program. Along with regional recognition, CSN provided a monetary award of $3,000. Staff’s
recommendation is to distribute the $3,000 monetary award equally to community partners who are working
with the Water Resources Department to provide environmental education to Lynchburg youth. The award
would be split equally between Camp Kum-Ba-Yah, The James River Association, and Claytor Nature Center.
Each community partner will receive $1,000 to provide scholarships for Lynchburg youth to attend
environmental education camps in the summer of 2021. The award money would allow for at least 12
Lynchburg students to attend an environmental education camp for a full week. All community partners offer
both full and partial scholarships, so it will be at the discretion of each organization to disperse the funds as
they see fit, as long as the youth is from the City of Lynchburg.
It is important to the awardees that the monetary award be reinvested into environmental education programs
in the community. Distributing the award money to these three community partners is an opportunity to foster
positive relationships with non-governmental organizations (NGOs) that support the department’s work in the
community. These NGOs will provide excellent educational and experiential learning opportunities to
Lynchburg youth, who otherwise may not be able to afford to participate these exemplary learning experiences
in the summer of 2021.
PRIOR ACTION(S): N/A
FISCAL IMPACT: None
CONTACT(S): Tim Mitchell, Director of Water Resources, 455-4252
ATTACHMENT(S): Resolution authorizing distribution of award money to community NGOs
REVIEWED BY: klw
050A
RESOLUTION:
BE IT RESOLVED that the Chesapeake Stormwater Network will distribute $3,000 on behalf of
Lynchburg Water Resources as follows: $1,000 to Camp Kum-Ba-Yah, $1,000 to The James River
Association, and $1,000 to Claytor Nature Center to fund Lynchburg youth to attend environmental
education camps in the summer of 2021.
Introduced: Adopted:
Certified: ____________________________
Clerk of Council
March 23, 2021
AGENDA ITEM #: 4
1
// A regular meeting of the Council of the City of Lynchburg was held on the 23rd day of March, 2021, at
4:00 P.M. in the Council Chamber, City Hall, MaryJane Dolan, President, presiding. The following
Members were present:
Present: MaryJane Dolan, Beau Wright, Jeff Helgeson, J. Randy Nelson, Treney Tweedy,
Sterling A. Wilder, Chris Faraldi 7
Absent: 0
// In the matter of Recognition, Mayor Dolan Proclaimed April 4 – 10, 2021 as Library Week in Lynchburg
and encouraged citizens of all ages to visit the local library online or in person to discover the many free
resources it has to offer for everyone. Ms. Beverly Blair, Director of Libraries was in attendance to accept.
// In the matter of Budget, Agenda Item #1, Chief Financial Officer Ms. Donna Witt reviewed the FY 2022
Projected Revenues. Staff, including the Commissioner of the Revenue and the City Assessor, will be
updating these revenue figures as more information becomes available and will have report out by April 6,
2021. Ms. Witt went through the following projected revenues: Current Real Property Tax; Current
Personal Property Tax – Local Portion; Local Sales and Use Tax; Consumer Utility Tax Electric;
Communications Sales and Use Tax; Business Licenses; Motor Vehicle Licenses; Lodging Tax; Meals
Tax; and Ambulance Service Fees.
Councilmember Faraldi asked for clarification regarding a line item on the Ambulance Service
Fees of $100 being charged to patients who receive emergency medical services but do not require
transport. He asked Ms. Witt to clarify if this was a new fee, to which she replied it was not.
Councilmember Nelson asked for further explanation with the increase to online sales. Ms. Witt
explained that this figure increased due to the Wayfair Act and because more people were buying things
online since the pandemic. Councilmember Nelson asked if she believed there could be an uptick in next
year’s revenues, or if the increase was simply due to the pandemic; his hope is that there will be extra
revenues in the coming years to accommodate equalizing the tax rate. Ms. Witt explained that she
believes the increase in online sales will level off once brick and mortar retail store open back up and
revenues will be shared between retail sales and online sales.
March 23, 2021
AGENDA ITEM #: 4
2
Councilmember Wilder asked for further explanation on the Real Property Tax Relief Program.
Ms. Witt explained that this program is for the disabled and the elderly and is administered through the
Commissioner of the Revenue.
Councilmember Helgeson added the following items to The List: Funds available above the
minimum 10% unassigned fund balance policy; Schools Funding; and the Trash Bag Decal Violation.
Councilmember Tweedy requested feedback in writing for the following item: understand the
financial involvement with the Rotary Centennial Skate Park.
// In the matter of Budget, Agenda Item #2, Interim City Manager Dr. Reid Wodicka reviewed with Council
the Proposed FY 2022 – 2026 Capital Improvement Program and gave an overview of each project.
Councilmember Helgeson added the following items to The List: Parking Lot Repairs and
Improvement/Multiple Projects. He also asked Mr. Brian Booth, Director of Greater Lynchburg Transit
Company (GLTC), if the transit company could utilize federal CARES funds for the 10% local match. Mr.
Booth stated that he would look into the matter. Councilmember Faraldi expressed the same sentiment as
Councilmember Helgeson. Councilmember Tweedy asked Mr. Booth if the CARES funds were received
due to the loss in ridership. Mr. Booth explained that the funds were due to ridership loss and revenue
loss is the primary source, however, in certain circumstances there is the ability to use it for some capital,
but will check to confirm what those are. If we use CARES funds we would be taking away the potential of
having those funds for future years in the operating budget.
Councilmember Nelson asked to add the following item to The List: Sandbar Removal – Hollins
Mill Road Trail Crossing.
// In the matter of Roll Call, Councilmember Faraldi asked staff for data on the cost of both a firefighter
position and police officer. Councilmember Wilder asked staff to explore a naming opportunity with
businesses for parking decks and other downtown renovation projects as a possible revenue source; he
also gave condolences for the families that were affected by both the Colorado and Atlanta shootings; he
paid tributes to the life of a community advocate and volunteer, Ms. Laura Munson. Councilmember
Tweedy noted that there has been trash on both the on- and off-ramps on the highway and that refuse
March 23, 2021
AGENDA ITEM #: 4
3
collection is important to keep in mind during budget discussions. Councilmember Nelson had no items.
Councilmember Helgeson agreed with Councilmember Tweedy that trash is a real problem for the city; he
also stated that he hoped that the Lynchburg City Schools would have opened back up by now. Vice
Mayor Wright had no items. Mayor Dolan made the following announcements:
• If you haven’t registered for the vaccine or have not updated your information please do so at
vaccinate.virginia.gov or call 877-VAX-IN-VA.
• The Lynchburg Regional Vaccination Center located in the Candlers Station Shopping Center
needs both medical and non-medical volunteers. In addition to vaccinators, the Center needs
NAVIGATORS, OBSERVERS, REGISTRATION, SCREENERS and SCRIBES. I encourage
you to sign up to help in this rewarding community effort by going to vaccinatecentralva.org.
You will find all the information you need to volunteer for this worthwhile effort! Together we
can do it!
• On Wednesday, April 7, at 7:00 p.m. join Bridges to Progress and the City of Lynchburg for a
Virtual Town Hall Meeting called, Faith, Facts, and the COVID Vaccine. A moderated panel
of Lynchburg faith leaders and healthcare professionals will discuss the COVID-19 vaccine
and its impact on communities of color. Look for more information soon on the City’s
Facebook page.
// The meeting was recessed at 6:08 p.m.
// City Council reconvened the meeting at 7:30 p.m. The following members were present:
Present: MaryJane Dolan, Beau Wright, Jeff S. Helgeson, J. Randy Nelson, Treney Tweedy,
Sterling A. Wilder, Chris Faraldi 7
Absent: 0
Councilmember Faraldi gave the Invocation, followed by the Pledge of Allegiance.
// In the matter of the Consent Agenda Item #4, copies of the minutes of the March 9, 2021 meeting have
been previously furnished to Council, and on motion of Councilmember Nelson, seconded by
Councilmember Wilder, Council by the following recorded vote approved the minutes as presented:
March 23, 2021
AGENDA ITEM #: 4
4
Ayes: Dolan, Wright, Helgeson, Nelson, Tweedy, Wilder, Faraldi 7
Noes: 0
// In the matter of Community Development, Agenda Item #5, Council considered adopting Resolution #R-
21-021 approving the allocation of the FY 2022 Community Development Block Grant (CDBG) and
HOME Program funds and incorporating the FY 2022 CDBG Fund and HOME Fund Budgets and
Program Year 2021 Annual Action Plan.
Ms. Melva Walker, Grants Manager, provided Council with a brief summary of the request. The
U.S. Department of Housing and Urban Development (HUD) funds the CDBG and HOME Programs. The
City has available the following funds to use for eligible CDBG and HOME activities during FY 2022 (PY
2021).
CDBG AVAILABLE FUNDING/SOURCE AMOUNT
HUD Entitlement Allocation $718,593.00
Reprogrammed Funds _ 22,712.47
Total CDBG Funding Available $741,305.47
HOME AVAILABLE FUNDING AMOUNT
HUD Entitlement Allocation $413,856.00
Reprogrammed Funds 54,568.87
Total HOME Funding Available $468,424.87
All CDBG and HOME funds will be expended in accordance with primary objectives of the
programs. The City estimates that over 70% of the CDBG FY 2022 funding will benefit low/moderate
income persons which complies with HUD regulations. All applications submitted for funding
consideration are available for review in the Grants Administration Office, Second Floor, City Hall.
At the conclusion of the public hearing, City Council will review the recommendations of the
CDAC and approve the funding allocations to be included in the FY 2022 CDBG Fund and HOME Fund
March 23, 2021
AGENDA ITEM #: 4
5
Budgets and PY 2021 CDBG and HOME Program Annual Action Plan. The Annual Action Plan will
subsequently be submitted to HUD for approval.
There was no one in person to either speak in favor or opposition. There were several
correspondences previously furnished to the Clerk of Council which were then read into the record. M s.
Olyvia Brown-Coles, Director of Housing Services at Lynchburg Community Action Group (Lyn -CAG),
spoke on behalf of the group to request Council consider approving the funds related to its HOME project,
First Time Homebuyer Down Payment Assistance Program. Mr. Jeff Smith, Executive Director of Rush
Homes, spoke on behalf of the group to request Council consider approving the funds related to its
HOME project Florida Terrace Rental Housing. Ms. Donna Vincent, Executive Director of Greater
Lynchburg Habitat for Humanity, spoke on behalf of the group to request Council consider approving the
funds related to its HOME project Knott Street Development. Ms. Sarah Quarantotto, Executive Director
of Miriam’s House, spoke on behalf of the group to request Council consider approving funds related to
the CDBG project, Lynchburg Redevelopment and Housing Authority Centralized Homeless Intake
Coordinator. At the conclusion of citizen input, the public hearing was closed and the matter rested with
Council.
Vice Mayor Wright, Chair of CDAC, reviewed the projects recommended for approval:
CDBG:
City Administration $126,500.00
Jefferson Park Revitalization Improvements $507,017.47
Lynchburg Redevelopment and Housing Authority (LRHA) Centralized Homeless Intake Coordinator $65,000.00
LRHA Affordable Housing Resource Center $42,788.00
Total CDBG $741,305.47
HOME:
City Administration $33,000.00
Rush Lifetime Homes- Florida Terrace Rental Housing (CHDO) $150,000.00
Greater Lynchburg Habitat for Humanity Knott Street Development $208,424.87
Lynchburg Community Action Group (Lyn-CAG)- Down Payment Assistance $77,000.00
Total HOME $468,424.87
March 23, 2021
AGENDA ITEM #: 4
6
Vice Mayor Wright made the motion to approve the recommendations, seconded by
Councilmember Tweedy.
Councilmember Helgeson asked for clarification on the increase in funds for the line item “City
Administration” for the CDBG funds. Mr. Kent White, Interim Deputy City Manager, indicated that the
increase will help fund the extra support needed to maintain these funds for the projects. These are five-
year grants and the city has several CDBG COVID grants that are requiring a lot of staff time.
Councilmember Helgeson wishes that more of the money would go to projects and n ot administration.
With no other discussion from Council, the following vote was recorded approving Resolution #R -
21-021.
Ayes: Dolan, Wright, Helgeson, Nelson, Tweedy, Wilder, Faraldi 7
Noes: 0
// In the matter of Public Comment, Agenda Item #6, Mr. Andrew Glover spoke to Council about its
decision at its February 23, 2021 meeting to hold a public hearing at a later date regarding the renaming
of 5th Street to Martin Luther King, Jr. Boulevard. Mr. Glover commented that the request generated from
seemingly very little community impetus and urged Council to also hold a public hearing to garner citizen
feedback from parents on reopening Lynchburg City Schools.
// In the matter of Parking, Agenda Item #7, Council considered adopting an ordinance amending Chapter
25; Division 3 – Permit Parking of the City Code. Mr. David Malewitz, Director of Parking Management,
provided Council with a brief summary of the request. The Lynchburg Parking Authority (LPA) at its
February 9, 2021 meeting recommended City Council adopt revisions to the City Code that would modify
code language to effectively manage residential parking permits and permitted districts. Highlights of the
proposed revisions include (i) allowing the Department of Parking Management to establish rules and
fees for visitor permits, (ii) the creation of two distinct residential permit parking districts in the Central
Business District, (iii) replace the yearly on-street residential parking permits in the Central Business
District with a monthly permit and establish a new monthly parking permit rate for on-street residential
parking permits, (iv) institute a $5 late fee after the 5th of the month for monthly permits not renewed by
March 23, 2021
AGENDA ITEM #: 4
7
the first of the month, and (v) establish rules to allow the Lynchburg Parking Authority board to set
monthly residential parking permit rates for all off-street City-owned or City-managed parking facilities.
The recommendations are consistent with the Lynchburg Parking Authority 2019 -2021 Comprehensive
Work Plan. The plan is designed to identify parking specific strategies focused on continually maintaining,
improving, and increasing parking opportunities in the Central Business District.
Councilmember Helgeson stated a concern with increasing the business parking permits.
Businesses, who in essence are only occupying the space for eight hours a day, pay a higher rate than a
residential permit holder who could be maintaining the space twenty-four hours a day. He further stated
that the downtown area is a business zone but preferential treatment is being granted to residential permit
holders. He also stated that he would like to strike the addition of allowing the LPA to set monthly
residential permit rates in off-street parking facilities since the LPA is an appointed body whose purpose
is to recommend rates to Council.
Councilmember Faraldi stated that he would be in favor of including a grandfather clause for the
individuals in the Central Business District who would be affected by the change from a yearly rate to a
new monthly permit at a higher rate.
Councilmember Tweedy commented that businesses will receive a tax write-off at the end of the
year and will receive a benefit. Councilmember Helgeson stated that it is plausible that not all businesses
pay for their employees parking and that employees will be affected with the increased business rate.
Councilmember Wilder asked if there was any residential and downtown business representation
on the committee that recommended these changes. Mr. Malewitz explained that there was downtown loft
management representation, business owners, and the Downtown Lynchburg Association representation
on LPA. Councilmember Wilder commented that parking downtown during the day is more in demand so
he is supportive of the higher business permit rate. He is also supportive of a grandfather clause and
removing the authority of the LPA to set rates.
Deputy City Attorney Mr. Matthew Freedman commented that the Lynchburg Parking Authority
Act had already been adopted under state law which permits the LPA to set rates for off-street facilities.
He suggested that Council could include language in the ordinance that the LPA will consider a
recommendation from Council as it relates to those rates. He reiterated that Council regulates the on-
March 23, 2021
AGENDA ITEM #: 4
8
street rates, however, because of the Lynchburg Parking Authority Act, the LPA has the power to regulate
off-street City maintained facilities. Vice Mayor Wright asked if this was just a housekeeping item to align
City Code with state law to which Mr. Freedman replied that it was.
Councilmember Nelson stated that he would be in favor of the LPA setting monthly residential
parking permit rates for all off-street City-owned or City-managed parking facilities as long as it was
written in the ordinance that the LPA would hold a public hearing with the affected audience in order to
learn of the needs of those they serve. He also stated that he is very reluctant to increase any fees or
taxes during a pandemic if it can be helped. He also stated that the rate should go up for on-street
parking. He commented that he would like to see this delayed so as to discuss with a little more detail to
make sure Council assess properly.
Interim City Manager Dr. Reid Wodicka reiterated that staff will bring this item back for Council’s
consideration after the addition of language addressing a grandfather clause, as well as a codifying a rate
setting process for the Lynchburg Parking Authority, and further consideration to the business rates.
Councilmember Tweedy asked staff to survey businesses downtown to see who pays for their employees
parking.
Mr. Malewitz reminded Council that there is a time constraint associated with this item due to the
sale of on-street parking permits that begin on April 15th.
// In the matter of the Fire Department, Agenda Item #8, Council received the first reading of Resolution
#R-21-022 amending the FY 2021 City/Federal/State Aid Fund budget and appropriate $67,200 with
resources to purchase eighteen Pharm Guard Temperature Controls systems for pharmacy drug boxes
carried on fire and EMS apparatus for the Fire Department.
Fire Chief Greg Wormser provided Council with a brief summary of the request. The Virginia Office
of Emergency Medical Services (EMS) awards grant funding to EMS agencies for the purpose of
obtaining and maintaining emergency vehicles and equipment; providing EMS management, le adership,
and advanced life support training; and achieving other goals that support the enhancement of community
EMS services. The Fire Department has been awarded RSAF grant funds to purchase eighteen Pharm
Guard Temperature Controls Systems for pharmacy boxes carried on fire and EMS apparatus. These
March 23, 2021
AGENDA ITEM #: 4
9
devices are designed to provide climate control for the medications on each of the apparatus. The
medications the department carry must be climate controlled in accordance with Virginia Office of EMS
regulations to ensure efficacy. The grant requires a local match. The Fire Department applied for these
funds under a Hardship Request, which would have required the locality to pay 20 percent and RSAF
would have paid 80 percent. However, the RSAF funds were awarded with a required 50 percent match.
With a total cost of $67,200, the required local match is $33,600. The match will be funded from the FY
2021 General Fund Fire Department budget.
At its March 23, 2021 meeting, the Finance Committee recommended approval. As Chair of that
committee, Councilmember Helgeson brought the committee’s recommendation for approval forward as a
motion. No second was required, and with no discussion from Council, the following recorded vote
approved the motion:
Ayes: Dolan, Wright, Helgeson, Nelson, Tweedy, Wilder, Faraldi 7
Noes: 0
//On motion of Councilmember Wilder, seconded by Councilmember Tweedy, Council, by the following
recorded vote, elected to hold a closed meeting for the discussion of discussion and consideration of
information provided to the City by a private entity under the provisions of the Public -Private
Transportation Act relating to the possible construction of a Police Headquarters Facility, pursuant to
Sections 2.2-3711(A.) (28) and 2.2-3705.6(11) of the Code of Virgini, as amended.
With no discussion from Council, the following vote was recorded:
Ayes: Dolan, Wright, Helgeson, Nelson, Tweedy, Wilder, Faraldi 7
Noes: 0
// The meeting was reopened to the public.
// Councilmember Helgeson made the following motion:
March 23, 2021
AGENDA ITEM #: 4
10
WHEREAS, the Council of the City of Lynchburg has convened a closed meeting on this date, pursuant
to an affirmative recorded vote and in accordance with the provisions of The Virginia Freedom of
Information Act; and
WHEREAS, Section 2.2 3712 of the Code of Virginia requires a certification by City Council that
such closed meeting was conducted in conformity with Virginia law;
NOW, THEREFORE, BE IT RESOLVED that the Council of the City of Lynchburg certifies that, to
the best of each member's knowledge, (i) only public business matters lawfully exempted from open
meeting requirements by Virginia law were discussed in the closed meeting to which this certification
resolution applies, and (ii) only such public business matters as were identified in the motion convening
the closed meeting were heard, discussed or considered by Council.
The motion was seconded by Councilmember Faraldi, and Council, by the following recorded
vote, adopted the motion:
Ayes: Dolan, Wright, Helgeson, Nelson, Tweedy, Wilder, Faraldi 7
Noes: 0
// Councilmember Tweedy made a statement supporting the Lynchburg City Schools Return to Learn
Plan.
// The meeting adjourned at 9:26p.m.
____________________________
Clerk of Council
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 6
CONSENT: REGULAR: X WORK SESSION: CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: Appalachian Power Company (AEP) Electric Line Easement 2521 Old Wards Road
(Milestone Tower Site)
KEY ELEMENTS:
___Economic Development _X_Excellent Government ___Natural and Built Environment ___Safe Community ___Vibrant Community
RECOMMENDATION: Hold a public hearing and adopt a resolution granting an easement, located at 2521
Old Wards Road, Lynchburg City Tax Map No. 16109001, for the extension of electric service to a new
Milestone Cell Tower.
SUMMARY: Milestone LP is presently constructing a Cell Tower on City Property off Old Wards Road. As part
of the project, it is necessary for Appalachian Power Company to acquire, from the City, easements to extend
an electric service line from Old Wards Road to the tower.
PRIOR ACTION(S): April 13, 2021: The Physical Development Committee recommended approval of the
easement.
August 11, 2020 – City Council approved a Conditional Use Permit petition to allow the construction of a one
hundred fifty-four (154) foot monopole to be used for telecommunications at 1501 Fenwick Drive.
FISCAL IMPACT: None
CONTACT(S): Lee Newland, City Engineer – 455-3947
Gaynelle Hart, Director of Public Works – 455-4406
ATTACHMENT(S): Resolution
Easement Plat
REVIEWED BY: klw
048A
RESOLUTION:
BE IT RESOLVED THAT: The Lynchburg City Council hereby authorizes Reid Wodicka, Interim City Manager,
and/or his designees, to execute a right of way and easement agreement with Appalachian Power Company for
the installation and maintenance of a power line in order to serve the Milestone Cell Tower on city property, Tax
Parcel Number 16109001.
Adopted:
Certified: ____________________________
Clerk of Council
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 7
CONSENT: REGULAR: X WORK SESSION: CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: Appalachian Power Company (AEP) Electric Line Easement 409 Perrymont Avenue
KEY ELEMENTS:
___Economic Development _X_Excellent Government ___Natural and Built Environment ___Safe Community ___Vibrant Community
RECOMMENDATION: Hold a public hearing and adopt a resolution granting an easement, located at 409
Perrymont Avenue, Lynchburg City Tax Map No. 05613002, for the extension of electric service to a new
gymnasium.
SUMMARY: Lynchburg City Schools is presently constructing a new gymnasium at Perrymont Elementary
School. As part of the project, it is necessary for Appalachian Power Company to acquire, from the City,
easements to extend an electric service line from the right of way to the gym.
PRIOR ACTION: April 13, 2021 – Physical Development Committee recommended approval of the
easement.
FISCAL IMPACT: None
CONTACT(S): Lee Newland, City Engineer – 455-3947
Gaynelle Hart, Director of Public Works – 455-4406
ATTACHMENT(S): Resolution
Easement Plat
REVIEWED BY: klw
049A
RESOLUTION:
BE IT RESOLVED THAT: The Lynchburg City Council hereby authorizes Reid Wodicka, Interim City Manager,
and/or his designees, to execute a right of way and easement agreement with Appalachian Power Company for
the installation and maintenance of a power line in order to serve the Perrymont School Gymnasium on city
property, Tax Parcel Number 05613002.
Adopted:
Certified: ____________________________
Clerk of Council
APPALACHIAN POWER COMPANY
EXHIBIT "A" DATED 11-11-2020
PROPOSED RIGHT OF WAY AND EASEMENT
ON THE PROPERTY OF: CITY OF LYNCHBURG
DRAWN BY : DENNIS SMITH
TAX PARCEL# 05613002
NO SCALE
CITY OF LYNCHBURG
PARCEL # 05613002
NEW POLE
NEW POLE
NEW POLE
PROPOSED
CENTERLINE
NEW
GYMNASIUM
PROPERTY LINE
N
1
Finney, Alicia
From: Brandon Barney <bbarney2475@gmail.com>
Sent: Wednesday, April 21, 2021 10:57 AM
To: Finney, Alicia
Subject: Re: City Council meeting
CAUTION: External Sender
Firefighter ment
al health and burnout
On Wed, Apr 21, 2021, 6:52 AM Finney, Alicia <Alicia.Finney@lynchburgva.gov> wrote:
Hello Mr. Barney,
I’m happy to place you on our agenda for next Tuesday night’s (April 27) Council meeting under Public Comment. Could
you please provide a brief summary of what you’d like to talk about? A sentence should do.
Thank you!
ALICIA L. FINNEY – Clerk of Council
City of Lynchburg
900 Church Street
Lynchburg, VA 24504
P: (434) 455‐3990 F: (434) 847‐1536
*Formerly alicia.campbell@lynchburgva.gov
From: Brandon Barney <bbarney2475@gmail.com>
Sent: Tuesday, April 20, 2021 4:28 PM
To: Finney, Alicia <Alicia.Finney@lynchburgva.gov>
Subject: City Council meeting
AGENDA ITEM #: 8
2
CAUTION: External Sender
Alicia,
I am a retired fireman and would like to speak on my behalf
054A
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 9
CONSENT: REGULAR: X WORK SESSION: X CLOSED SESSION:
ACTION: INFORMATION: (Confidential)
ITEM TITLE: City Code Amendment Chapter 17 – Fences and Walls, Section 17-22, Electrically Charged Fences
KEY ELEMENTS:
_ _Economic Development _X_Excellent Government _X_Natural and Built Environment _ X Safe Community _ _Vibrant Community
RECOMMENDATION: Consider amending Section 17-22, Electrically Charged Fences to allow electrically
charged security fences in non-residential areas.
SUMMARY: Electrically charged fences are not currently permitted in the City. Mr. Donald McLellan,
AMAROCK, LLC has requested that City Council consider amending the City Code to allow electrically
charged security fences in non-residential areas. City staff has reviewed a “model” ordinance provided by Mr.
McLellan as well as similar ordinances from other Virginia First Cities and drafted amendments for City
Council’s consideration.
The draft ordinance proposes:
• Allowing electrically charged security fences around the perimeter of non-residential outside storage
areas.
• Requiring compliance with International Standard IEC 60335-2-76.
• Requiring a non-electric fence to surround the perimeter of the electric fence.
• Setting a maximum height of ten (10) feet.
• Requiring identification of the electric fence with warning signs.
• Requiring notification to the City’s Police & Fire Departments upon installation.
PRIOR ACTION(S):
January 28, 2020: City Council repealed Sections of the City Code pertaining to Fences and Walls that
conflicted with the Zoning Ordinance and the Code of Virginia.
FISCAL IMPACT: N/A
CONTACT(S): Tom Martin, City Planner – 455-3900
Mr. Donald McLellan, AMAROCK, LLC – (803) 201-1773
ATTACHMENT(S):
• Ordinance
• Presentation Slides
• International Standard IEC 60335-2-76
• Model Ordinance
REVIEWED BY: klw
053A
AN ORDINANCE TO AMEND AND REENACT SECTION 17-22 OF THE CODE OF THE CITY OF
LYNCHBURG, 1981, THE AMENDED SECTION RELATING TO ELECTRICALLY CHARGED FENCES
WITHIN THE CITY.
BE IT ORDAINED BY THE COUNCIL OF THE CITY OF LYNCHBURG:
1. That Section 17-22 of the Code of the City of Lynchburg, 1981, be and the same is hereby amended and
reenacted as follows:
Sec. 17-22. - Electrically charged fence.
No electrically charged fence shall be erected or maintained within the city.
A. As used in this section “electric fence” shall mean a fence designed to conduct electric current along
one (1) or more wires thereof so that a person or animal touching any such wire or wires will receive an
electric shock.
B. The construction and use of electric fences shall be allowed in the city only as provided in this section
and subject to the following standards:
1. Unless otherwise specified herein, electric fences shall be constructed and installed in conformance
with the specifications set forth in the International Standard IEC 60335-2-76.
2. Electrification
(a) The energizer for electric fences shall be driven by a commercial storage battery not to exceed twelve
(12) volts DC. The storage battery shall be charged primarily by a solar panel; however, the solar panel
may be augmented by a commercial trickle charger.
(b) The electric charge produced by the fence upon contact shall not exceed energizer characteristics set
forth in paragraph 22.108 and depicted in Figure 102 of International Standard IEC 60335-2-76.
3. Perimeter fence or wall: No electric fence shall be installed or used unless it is completely surrounded
by a non-electrical fence or wall that meets the standards of the Zoning Ordinance.
4. Location: Electric fences shall only be permitted along the perimeter of non-residential storage areas.
5. Height: Electric fences shall not exceed a height of two (2) feet above the height of the perimeter
fence.
6. Warning signs: Electric fences shall be clearly identified with warning signs that read “Warning –
Electric Fence” at intervals of not less than thirty (30) feet.
7. A Knox Remote Power Box or equivalent device acceptable to the City’s Police & Fire Departments
shall be installed with the capability of deenergizing the fence during an emergency.
8. Notification: Upon installation of an electric fence the owner of the property shall notify the City’s Police
Department & Fire Department of the location of the electric fence and the device capable of
deenergizing the electric fence.
2. That this ordinance shall become effective upon its adoption.
Adopted:
Certified: ____________________________
Clerk of Council
Electric Fences
Tom Martin, AICP City Planner
City Council
April 27, 2021
Purpose and Outline
Purpose: Discuss allowing electrically charged security fences
Outline:
1. City Code
2. Background
3. Considerations
4. Discussion
2
City Code
• Chapter 17 – Fences and Walls, Section 17-22
• Electrically charged fences prohibited in City since 1959
• January 28, 2020 – City Council repealed Sections of City Code pertaining
to Fences and Walls that conflicted with Zoning Ordinance
3
Background
• AMAROCK, LLC is requesting City Council consider amending
City Code to allow electrically charged security fences
• AMAROCK, LLC has provided a “model” ordinance
• International Standard IEC 60335-2-76 lists requirements for
electric fence energizers
4
Considerations
• Leave current prohibition
• Allow in non-residential areas with standards
• Public Safety Considerations
• Permitting & Inspection Considerations
5
Discussion:
Discussion
6
INTERNATIONAL
STANDARD
IEC
60335-2-76
Second edition
2002-08
Household and similar electrical appliances –
Safety –
Part 2-76:
Particular requirements for electric fence
energizers
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-76:
Règles particulières pour les électrificateurs
de clôtures
Reference number
IEC 60335-2-76:2002(E)
Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in the
60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.
Consolidated editions
The IEC is now publishing consolidated vers ions of its publications. For example,
edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the
base publication incorporating amendment 1 and the base publication incorporating
amendments 1 and 2.
Further information on IEC publications
The technical content of IEC publications is kept under constant review by the IEC,
thus ensuring that the content reflects current technology. Information relating to
this publication, including its validity, is available in the IEC Catalogue of
publications (see below) in addition to new editions, amendments and corrigenda.
Information on the subjects under consi deration and work in progress undertaken
by the technical committee which has prepared this publication, as well as the list
of publications issued, is also available from the following:
• IEC Web Site ( www.iec.ch )
• Catalogue of IEC publications
The on-line catalogue on the IEC web site ( www.iec.ch/catlg-e.htm ) enables
you to search by a variety of criteria including text searches, technical
committees and date of publication. On -line information is also available on
recently issued publications, withdrawn and replaced publications, as well as
corrigenda.
• IEC Just Published
This summary of recently issued publications ( www.iec.ch/JP.htm ) is also
available by email. Please contact the Customer Service Centre (see below) for
further information.
• Customer Service Centre
If you have any questions regarding this publication or need further assistance,
please contact the Customer Service Centre:
Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL
STANDARD
IEC
60335-2-76
Second edition
2002-08
Household and similar electrical appliances –
Safety –
Part 2-76:
Particular requirements for electric fence
energizers
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-76:
Règles particulières pour les électrificateurs
de clôtures
IEC 2002 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
S
For price, see current catalo gue
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
Межд
ународная Элект ротехническая Комиссия
– 2 – 60335-2-76 IEC:2002(E)
CONTENTS
FOREWORD ....................................................................................................................... ... 4
INTRODUCTION ................................................................................................................... .6
1 Scope ......................................................................................................................... ..... 7
2 Normative references....................................................................................................... 7
3 Definitions ................................................................................................................... .... 7
4 General requirement .......................................................................................................11
5 General conditions for the tests ......................................................................................11
6 Classification ................................................................................................................ ..12
7 Marking and instructions .................................................................................................12
8 Protection against access to live parts ............................................................................13
9 Starting of motor-operated appliances ............................................................................14
10 Power input and current..................................................................................................14
11 Heating...................................................................................................................... .....14
12 Void ......................................................................................................................... .....15
13 Leakage current and electric strength at operating temperature ......................................15
14 Transient overvoltages....................................................................................................15
15 Moisture resistance.........................................................................................................1 7
16 Leakage current and electric strength .............................................................................17
17 Overload protection of transformers and associated circuits............................................18
18 Endurance .................................................................................................................... ..18
19 Abnormal operation.........................................................................................................19
20 Stability and mechanical hazards....................................................................................21
21 Mechanical strength........................................................................................................21
22 Construction ................................................................................................................. ..21
23 Internal wiring.............................................................................................................. ...24
24 Components ................................................................................................................... 24
25 Supply connection and external flexible cords.................................................................24
26 Terminals for external conductors ...................................................................................25
27 Provision for earthing......................................................................................................2 6
28 Screw and connections ...................................................................................................26
29 Clearances, creepage distances and solid insulation ......................................................26
30 Resistance to heat and fire .............................................................................................26
31 Resistance to rusting ......................................................................................................27
32 Radiation, toxicity and similar hazards ............................................................................27
Annexes........................................................................................................................ ........30
Annex AA (informative) Circuit for the independent control of the switching speed of
the major pulse-switching device...........................................................................................32
Annex BB (normative) Instructions for installation and connection of electric fences ............33
Annex CC (informative) Installation of electric security fences..............................................39
Bibliography................................................................................................................... .......43
60335-2-76 IEC:2002(E) – 3 –
Figure 101 – Schematic examples of the different types of battery-operated energizers
suitable for connection to the mains ......................................................................................28
Figure 102 – Current limited energizer characteristic limit line...............................................29
Figure AA.1 – Circuit for the independent control of the switching speed of the major
pulse-switching device ......................................................................................................... .32
Figure BB.1 – Symbol for warning sign..................................................................................38
Figure CC1 – Prohibited area for pulse conductors ...............................................................40
Figure CC2 – Typical constructions where an electric security fence is exposed to the
public ......................................................................................................................... ...........41
Figure CC3 – Typical fence constructions where the electric security fence is installed
in windows and skylights ....................................................................................................... 42
Table 101 – Battery source impedance .................................................................................15
Table 102 – Additional test voltages ......................................................................................17
Table BB 1 – Minimum clearances from power lines for electric animal fences ......................34
Table BB 2 – Minimum clearances from power lines for electric security fences ....................36
– 4 – 60335-2-76 IEC:2002(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-76: Particular requirements for electric fence energizers
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61H:
Safety of electrically operated farm appliances, of IEC technical committee 61: Safety of
household and similar electrical appliances.
This second edition cancels and replaces the first edition published in 1997 and its
amendment 1 (1999). It constitutes a technical revision.
The text of this part of IEC 60335 is based on the following documents:
FDIS Report on Voting
61H/173/FDIS 61H/174/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for electric fence
energizers.
60335-2-76 IEC:2002(E) – 5 –
When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies
as far as is reasonable. When this standard states “addition”, “modification” or “replacement”,
the relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional Annexes are lettered AA, BB, etc.
NOTE 3 The following print types are used:
– requirements: in roman type
– test specifications: in italic type
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and
associated noun are also in bold.
The committee has decided that the contents of this publication will remain unchanged until
2004. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
The following differences exist in the countries indicated below:
– 6.101: Only energy limited energizers are allowed (Austria, Denmark, France, Germany, Netherlands,
Norway, Switzerland and United Kingdom).
A bilingual version of this publication may be issued at a later date.
– 6 – 60335-2-76 IEC:2002(E)
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in
normal use taking into account the manufacturer's instructions. It also covers abnormal
situations that can be expected in practice.
This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply
mains. However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features that impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of
the requirements and, if found to be substantially equivalent, may be considered to comply
with the standard.
60335-2-76 IEC:2002(E) – 7 –
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-76: Particular requirements for electric fence energizers
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric fence energizers , the rated
voltage of which is not more than 250 V and by means of which fence wires in agricultural,
feral animal control and security fences may be electrified or monitored.
NOTE 101 Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers ;
– battery-operated electric fence energizers suitable for connection to the mains , as shown in Figure 101;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not in general take into account
– the use of appliances by young children or infirm persons without supervision;
– the playing with appliances by young children.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used on board ships or aircraft, additional requirements may be necessary;
– in many countries additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
NOTE 103 This standard does not apply to
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601).
2 Normative references
This clause of Part 1 is applicable except as follows.
Addition:
IEC 60068-2-52, Environmental testing – Part 2: Tests – Test Kb: Salt mist, cyclic (sodium
chloride solution)
3 Definitions
This clause of Part 1 is applicable except as follows.
3.1.1 Addition:
For type D energizers , the rated voltage of the energizer is the rated voltage for battery
supply.
– 8 – 60335-2-76 IEC:2002(E)
3.1.6 Addition:
For battery-operated electric fence energizers not for connection to the mains, it is the
average input current assigned to the energizer by the manufacturer.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions: the electric fence energizer is
operated as in normal use when connected to the supply, with no load connected to the
output terminals
3.6.3 Addition:
NOTE 101 It also includes terminals for the connection of the battery and other metal parts in a battery
compartment that become accessible when replacing batteries even with the aid of a tool .
3.6.4 Replacement:
live part
conductive part that may cause an electric shock
3.101
electric fence energizer
appliance that is intended to deliver periodically voltage impulses to a fence connected to it
NOTE Electric fence energizers are hereinafter also referred to as energizers .
3.102
mains-operated energizer
energizer designed for direct connection to the mains
3.103
battery-operated energizer suitable for connection to the mains
energizer
– operated by batteries and having, or being designed for connection to, facilities for
charging these batteries from the mains, or
– designed for operation from the mains and from batteries
3.104
type A energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit, a battery charging circuit and a battery, the impulse generating circuit
being connected to the mains or the battery when the energizer is in operation
NOTE Type A energizers are shown schematically in Figure 101.
3.105
type B energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit, a battery charging circuit and a battery, the impulse generating circuit
being connected to the battery and disconnected from the battery charging circuit and the
mains when the energizer is in operation. For recharging the battery the impulse generating
circuit is disconnected and rendered inoperable
NOTE Type B energizers are shown schematically in Figure 101.
60335-2-76 IEC:2002(E) – 9 –
3.106
type C energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit and a battery, the impulse generating circuit being connected to the mains
or the battery when the energizer is in operation, and where it is necessary to remove the
battery to recharge it using a separate battery charger or, in the case of a non-rechargeable
battery, to replace it with a new battery
NOTE Type C energizers are shown schematically in Figure 101.
3.107
type D energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit intended to be powered by a battery, the impulse generating circuit being
connected to the battery when the energizer is in operation and the energizer or the battery
being connected to a separate battery charger for recharging the battery
NOTE Type D energizers are shown schematically in Figure 101.
3.108
battery-operated energizer
energizer deriving its energy solely from batteries or other sources of energy and not
designed for connection to the mains
3.109
battery charger
appliance to be connected to the mains and intended for charging one or more batteries
3.110
fence
barrier for animals or for security purposes, comprising one or more conductors, such as
metal wires, rods or rails
3.111
fence circuit
all conductive parts or components within an energizer , that are connected or intended to be
connected galvanically to the output terminals
3.112
earth electrode
metal structure that is driven into the ground near an energizer and connected electrically to
the output earth terminal of the energizer , and that is independent of other earthing
arrangements
3.113
prospective peak voltage
peak output voltage of the impulse generator specified in Clause 14 that would be obtained
with the energizer not connected to the test circuit
3.114
rated voltage for battery supply
voltage for battery supply, for types A, B, C and D energizers , assigned to the energizer by
the manufacturer
3.115
rated voltage range for battery supply
voltage range for battery supply, for types A, B, C and D energizers , assigned to the
energizer by the manufacturer, expressed by its lower and upper limits
– 10 – 60335-2-76 IEC:2002(E)
3.116
impulse duration
duration of that part of the impulse that contains 95 % of the overall energy and is the shortest
interval of integration of I²(t) that gives 95 % of the integration of I²(t) over the total impulse
NOTE I(t) is the impulse current as a function of time.
3.117
output current
r.m.s. value of the output current per impulse calculated over the impulse duration
3.118
standard load
load consisting of a non-inductive resistor of 500 Ω ± 2,5 Ω and a variable resistor that is
adjusted so as to maximize the energy per impulse or output current in the 500 Ω resistor,
as applicable. The variable resistor is connected in series or parallel with the 500 Ω resistor,
whichever gives the more unfavourable result
3.119
electric fence
a barrier that includes one or more electric conductors, insulated from earth, to which electric
pulses are applied by an energizer
3.120
connecting lead
an electric conductor, used to connect the energizer to the electric fence or the earth
electrode
3.121
electric animal fence
an electric fence used to contain animals within or exclude animals from a particular area
3.122
electric security fence
a fence used for security purposes that comprises an electric fence and a physical barrier
electrically isolated from the electric fence
3.123
physical barrier
a barrier not less than 1,5 m high intended to prevent inadvertent contact with the pulsed
conductors of the electric fence
NOTE Physical barriers are typically constructed from vertical sheeting, rigid vertical bars, rigid mesh, rods or
chainwire mesh.
3.124
public access area
any area where persons are protected from inadvertent contact with pulsed conductors by
a physical barrier
3.125
pulsed conductors
conductors that are subjected to high voltage pulses by the energizer
3.126
secure area
an area where a person is not separated from pulsed conductors below 1,5 m by a physical
barrier
60335-2-76 IEC:2002(E) – 11 –
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.2 Modification:
Replace the test specification by the following:
The tests are made on two energizers as delivered, one being subjected to all the tests with
the exception of that of Clause 18, and the other to the tests of clause 5 and Clause 18.
However, the tests of Clauses 22 to 28 may be made on separate samples.
For types A and C energizers , an additional sample is required for the test of Clause 18.
Addition:
NOTE 101 Where electronic circuits , electronic components or other devices are normally encapsulated,
specially prepared samples may be needed for the tests of 19.11 and 19.101.
5.3 Addition:
The measurements of 22.108 shall be carried out before the tests of Clause 14. The tests
specified in 14.101 shall be carried out on all appliances.
If any electronic component has been damaged during the tests of Clause 14, the tests of
Clause 19 are made twice, once before and once after the damaged electronic components
have been replaced by new electronic components .
5.5 Addition:
The energizer is mounted in a normal position such that the deviation from the position for
which it is designed does not exceed 15°. However, if the energizer is provided with means
for adjustment to the normal position, such as a spirit level, the energizer shall be adjusted to
within ±2° of the normal position.
The earthing terminal of the fence circuit is connected to earth. However, if there is no
indication as to which of the output terminals is to be connected to earth, the terminal that
gives the most unfavourable result is earthed.
5.8.1 Addition:
For types A, B, C and D energizers where the terminals for the connection of the battery
have no indication of polarity, the more unfavourable polarity of the voltage source replacing
the battery shall be applied.
For battery-operated energizers where the supply terminals for the connection of the battery
have no indication of polarity, the more unfavourable polarity shall be applied.
For mains-operated energizers and battery-operated energizers suitable for connection
to the mains , the reference source impedance of the mains supply shall be 0,4 Ω + j0,25 Ω .
5.101 All energizers are tested as motor-operated appliances .
– 12 – 60335-2-76 IEC:2002(E)
6 Classification
This clause of Part 1 is applicable except as follows.
6.1 Replacement:
Mains-operated energizers and battery-operated energizers suitable for connection to
the mains shall be class II with respect to protection against electric shock.
Compliance is checked by inspection and by the relevant tests.
6.2 Addition :
Energizers shall be of at least IPX4.
6.101 Energizers are classified as being either energy limited energizers or current
limited energizers.
Compliance is checked by the appropriate tests.
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
Energizers shall be marked with symbol 1641 of ISO 7000.
Types A, B and C energizers shall be marked with the rated voltage for battery supply or
rated voltage range for battery supply , in volts.
Battery-operated energizers shall be marked with the substance of the following:
WARNING: Do not connect to mains-operated equipment.
Energy limited energizers that are marked with a maximum energy/impulse exceeding 5 J
shall also be marked with the corresponding load resistance at which maximum
energy/impulse is obtained.
7.6 Addition:
[symbol 5036 of IEC 60417 ] Dangerous voltage
[symbol 5017 of IEC 60417 ] Earth (ground)
The symbols for output ( Fence ) and output (Earth) shall be in accordance with symbols 5036
and 5017 of IEC 60417 respectively.
60335-2-76 IEC:2002(E) – 13 –
7.12 Addition:
Instructions for types A, B and D energizers shall
– include a warning against using non-rechargeable batteries;
– state that, during charging, lead-acid batteries must be placed in a well-ventilated area.
The instructions for battery-operated energizers shall in particular emphasize the warning
marked on the energizer that states the substance of the following:
WARNING: Do not connect to mains-operated equipment.
7.101 Unless the correct mode of connection is obvious, the output terminals shall be clearly
and indelibly identified by marking with the words EARTH and FENCE, or with symbols 5017
and 5036 of IEC 60417 respectively.
Where alternative output terminals are provided they shall be similarly marked, or marked with
the words FULL POWER, REDUCED POWER or REDUCED VOLTAGE, as appropriate.
If a switch to control the output energy is provided, the various positions of the switch shall be
marked with the appropriate symbols, or with the words FULL POWER, REDUCED POWER or
REDUCED VOLTAGE, as appropriate.
The lettering of the marking shall have a height of at least 3 mm and the symbols a height of
at least 6 mm.
Compliance is checked by inspection and measurement.
7.102 For types A, B, C and D energizers and battery-operated energizers the supply
terminals for connection of the battery shall be clearly indicated by the symbol “+” or the
colour red, if of positive polarity, and by the symbol “–” or the colour black, if of negative
polarity, unless the polarity is irrelevant.
Compliance is checked by inspection.
7.103 Energizers shall be supplied with instructions that contain information regarding
– the installation of electric fences;
– the means of connecting the energizer to the electric fence .
Such information shall contain the substance of the wording given in BB.1 ( electric animal
fences ) or Annex BB.2 ( electric security fences ), as appropriate.
NOTE It is recommended that energizers intended for use with electric security fences also be supplied with
the information given in Annex CC.
Compliance is checked by inspection.
8 Protection against access to live parts
This clause of Part 1 is applicable except as follows.
8.1.4 Addition:
The means for the connection of the fence is not considered to be a live part .
– 14 – 60335-2-76 IEC:2002(E)
9 Starting of motor-operated appliances
This clause of Part 1 is not applicable.
10 Power input and current
This clause of Part 1 is applicable except as follows.
10.101 For energy limited energizers that are marked with a maximum energy/impulse
exceeding 5 J, the value so marked shall not deviate from that delivered by more than ±10 %
and the load resistance at which it is obtained shall not deviate from the value marked on the
energizer by more than ±5 %.
Compliance is checked by the following test.
The energizer is supplied at rated voltage or rated voltage for battery supply , as
appropriate, under conditions of normal operation but with a variable resistive load
connected across its output terminals.
The energy per impulse dissipated in the resistive load connected across the energizer
output terminals is measured using the measuring arrangement described in 22.108. The
resistive load value is measured after it is adjusted to maximize the energy per impulse
measured.
11 Heating
This clause of Part 1 is applicable except as follows.
11.2 Addition:
For type A energizers when connected for mains supply, type D energizers when connected
for battery charger supply and type B energizers when connected for mains supply with
battery charge operation, a battery of the largest type for which the energizer is designed is
connected to the terminals for the connection of the battery supply. Before starting the test,
the battery is discharged to such an extent that the voltage delivered by the battery does not
exceed 0,75 times its nominal value.
11.5 Replacement:
The energizer is operated under normal operation , supplied as follows.
A mains-operated energizer is supplied with the most unfavourable supply voltage between
0,85 and 1,1 times rated voltage .
Types A and C energizers , when they are connected for mains supply, are supplied with the
most unfavourable supply voltage between 0,85 and 1,1 times rated voltage .
A type B energizer , when it is connected for mains supply with battery charge operation, is
supplied with the most unfavourable supply voltage between 0,85 and 1,1 times rated
voltage .
Types A, B, C and D energizers , when they are connected for battery supply, and battery-
operated energizers are supplied at the terminals for the connection of the battery with the
most unfavourable supply voltage between
60335-2-76 IEC:2002(E) – 15 –
• 0,55 and 1,1 times rated voltage for battery supply , if the energizer can be used
with non-rechargeable batteries;
• 0,75 and 1,1 times rated voltage for battery supply , if the energizer is designed for
use with rechargeable batteries only.
The values specified in Table 101 for the internal resistance per cell of the battery shall be
taken into account.
Table 101 – Battery source impedance
Internal resistance per cell
ΩSupply to the terminals for the
connection of the battery
Non-rechargeable
batteries
Rechargeable
batteries
1,1 times rated voltage for battery supply
1,0 times rated voltage for battery supply
0,75 times rated voltage for battery supply
0,55 times rated voltage for battery supply
0,08
0,10
0,75
2,00
0,0012
0,0015
0,0060
–
NOTE When determining the internal resistance of a battery, two or more cells connected in
parallel are considered to be one cell.
Type D energizers , when they are connected for battery charger supply, are supplied from a
source incorporating a series resistance of 1 Ω and having the form of
• a half-wave rectified sine-wave with an r.m.s. value equal to the rated voltage for battery supply,
• a full-wave rectified sine-wave with an r.m.s. value equal to the rated voltage for battery
supply ,
whichever is the more onerous.
11.7 Replacement:
The energizer is operated until steady conditions are established.
12 Void
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable except as follows.
13.1 Modification:
Compliance is checked by the tests of 13.2 and 13.3 for mains-operated energizers and
battery-operated energizers suitable for connection to the mains only.
Addition:
The energizer is operated under normal operation when supplied as specified in 11.5 for
mains operation.
14 Transient overvoltages
14.101 Energizers shall be resistant to atmospheric surges entering from the fence .
– 16 – 60335-2-76 IEC:2002(E)
Compliance is checked by the tests of
– 14.102 to 14.104 for mains-operated energizers and types A, B and C energizers ;
– 14.102 to 14.104 for type D energizers ;
– 14.104 for battery-operated energizers with a rated voltage exceeding 42,4 V.
NOTE The value of U0 is the peak value of the energizer output voltage obtained during the test of 22.111.
Unless otherwise specified, during the tests, no disruptive discharges shall occur but surge
protection devices are allowed to operate.
Mains-operated energizers and types A, B, C and D energizers are fixed to a metal plate
having dimensions that are at least 150 mm in excess of those of the orthogonal projection of
the energizer on the plate, and are then installed as in normal use.
Battery-operated energizers are installed as in normal use.
The tests are made by means of an impulse generator producing positive and negative full
lightning impulses having a front time of 1,2 µs and a time to half-value of 50 µs, the
tolerances being
• ±5 % for the peak value;
• ±30 % for the front time;
• ±20 % for the time to half-value.
Small oscillations in the impulse are allowed, provided their amplitude near the peak of the
impulse is less than 5 % of the peak value. For oscillations during the first half of the front
time, amplitudes up to 10 % of the peak value are allowed.
The shape of the impulses is adjusted with the energizer connected to the impulse generator.
The adjustment shall be made at approximately 50 % of the test voltage specified. If, for the
test of 14.104, it is not possible to obtain the correct shape of the impulses, it is only
necessary to ascertain that the front time has the required value at approximately 50 % of the
prospective peak voltage specified.
The impulse generator to be used for the tests shall have an energy content of at least 125 J
at the test voltage.
14.102 Five positive and five negative impulses, each having a prospective peak voltage
of 2U
0 but not less than 25 kV, are applied between
– the output terminals and a.c. input terminals connected together and the metal plate, for
mains-operated energizers and types A, B and C energizers ,
– the output terminals and the metal plate, for type D energizers ,
the interval between consecutive impulses being at least 10 s.
14.103 Five positive and five negative impulses, each having a prospective peak voltage
of 2U 0 but not less than 25 kV, are applied between the output terminals connected together
and
– the a.c. input terminals connected together, for mains-operated energizers and types A,
B and C energizers ,
– the terminals for connection of the external battery charger , for type D energizers ,
the interval between consecutive impulses being at least 10 s.
60335-2-76 IEC:2002(E) – 17 –
If, during this test, a surge protection device operates, the test is repeated with the surge
protection device rendered inoperative. During the repeat test no disruptive discharges are
allowed.
If the energizer has more than one fence circuit , each fence circuit is subjected to this test
in turn, the other fence circuits being open-circuited.
14.104 Five positive and five negative impulses, each having a prospective peak voltage
of 2U0 but not less than 25 kV, are applied between the output terminals, the interval between
the impulses being at least 10 s. The input terminals are open-circuited.
15 Moisture resistance
This clause of Part 1 is applicable.
16 Leakage current and electric strength
This clause of Part 1 is applicable except as follows.
16.1 Modification:
Compliance is checked by the tests of
– 16.2, 16.3 and 16.102 for mains-operated energizers and battery-operated energizers
suitable for connection to the mains;
– 16.101 and 16.102 for battery-operated energizers .
16.2 Modification:
The test voltage is the upper limit of the voltage in 11.5.
16.3 Addition:
Other values of the test voltages and the points of application are shown in Table 102.
Table 102 – Additional test voltages
Points of application Test voltage a
Between the supply circuit and accessible parts for
metal-encased class II energizers
Between the fence circuit and accessible parts b
Between the supply circuit and the fence circuit
2U0 but not less than 10 000 V
2U0 but not less than 10 000 V
2U0 but not less than 10 000 V
a The value 2 U0 is a peak value equal to twice the maximum peak value of the output voltage
measured in 22.111.
b A gap of 50 mm around the output terminal shall be provided in the metal foil in contact with
accessible parts .
– 18 – 60335-2-76 IEC:2002(E)
16.101 For battery-operated energizers the supply terminals are connected for 10 min to a
voltage between 1,1 and 1,5 times rated voltage for battery supply , that is so chosen that
the output voltage, without a load connected, has the maximum value, protective spark gaps,
if any, being disconnected.
The insulation between the poles of the supply circuit is then subjected for 1 min to a d.c.
voltage of approximately 500 V. Before this test is made, capacitors, resistors, inductors,
transformer windings and electronic components that are connected between the poles of
the supply circuit are disconnected. When a capacitor forms part of an integrated circuit and
cannot be disconnected separately, the circuit as a whole is disconnected.
No breakdown shall occur during the test.
16.102 Immediately after the tests of 16.3 and 16.101, the output characteristics are
measured as specified in 22.108.
The values measured shall be within the limits specified in 22.108 and shall not deviate in an
unfavourable way by more than 10 % from the values measured during the tests of 22.108.
17 Overload protection of transformers and associated circuits
This clause of Part 1 is not applicable.
18 Endurance
Energizers shall be so constructed that they are able to endure extreme temperatures that
may be encountered in normal use. Moreover, overload protection devices shall not operate
under these conditions.
Compliance is checked by the following test.
Mains-operated energizers , and types A and C energizers when they are connected for
mains supply are operated under conditions of normal operation . The voltage applied is the
rated voltage .
Type D energizers , when connected for battery charger supply, are operated under
conditions of normal operation . The voltage applied is as specified in 11.5.
Battery-operated energizers and type B energizers connected for battery operation are
placed in their normal position and are fitted with a battery having a nominal voltage equal to
the rated voltage for battery supply of the energizer . The battery shall be of the largest
type for which the energizer is designed. The battery shall be fully charged at the beginning
of the test and shall be replaced by a fresh one as soon as, during the test, the voltage of the
battery decreases to 0,75 times its nominal voltage for a rechargeable battery or to 0,55 times
its nominal voltage for a non-rechargeable battery.
For types A and D energizers , a battery of the largest type for which the energizer is
designed is connected and placed in the battery compartment. Before starting the test the
battery is discharged to such an extent that the voltage delivered does not exceed 0,75 times
its nominal value.
The other sample, for types A and C energizers , is to be connected for battery supply and
supplied from a battery of the largest type for which the energizer is designed. The battery
shall be fully charged at the beginning of the test, and shall be replaced by a fresh one as
soon as, during the test, the voltage of the battery decreases to 0,75 times its nominal voltage
for a rechargeable battery or to 0,55 times its nominal voltage for a non-rechargeable battery.
60335-2-76 IEC:2002(E) – 19 –
The energizer is operated continuously for 168 h (seven days) at an ambient temperature
of –15 °C ± 2 °C and then for 168 h (seven days) at an ambient temperature of 50 °C ± 2 °C.
The output terminals are loaded with a non-inductive resistor of 500 Ω ± 2,5 Ω during the
first 84 h of each period of 168 h and the load is removed for the remainder of these periods.
At the end of each of the periods of 168 h, the output characteristics are measured, as
specified in 22.108, at the ambient temperature prescribed for the relevant period.
The values measured shall be within the limits specified in 22.108 and shall not deviate in an
unfavourable way by more than 10 % from the values measured during the test of 22.108.
During the test, the energizer shall show no change impairing its further use, the sealing
compound, if any, shall not flow out to such an extent that live parts are exposed and the
energizer shall still meet the requirements of Clause 8.
19 Abnormal operation
This clause of Part 1 is applicable except as follows.
19.1 Modification:
Instead of the indication of the subclauses applicable to the various types of appliances, the
following applies.
Energizers are subjected to the tests of 19.11, 19.12, 19.101, 19.102, 19.103 and 19.104.
Addition:
The energizer is mounted as in 11.2, except that the battery, where applicable, is fully
charged.
During the tests, fuses that are accessible to the user are short-circuited.
19.11.1 Addition:
Components, except the major switching device, directly related to the pulse interval timing of
the major switching device where this is an electronic component , are exempt from the tests
of 19.11.2.
19.11.3 Not applicable.
19.12 Addition:
If, for any of the fault conditions, the impulse repetition rate is greater than 1 Hz and the
safety of the energizer depends upon the operation of a non-self-resetting protective
device incorporating an internal fuse, the test is carried out three times to ensure that this
fuse operates reliably and that internal parts are not damaged at the increased impulse
repetition rate.
– 20 – 60335-2-76 IEC:2002(E)
19.13 Addition:
During the tests the output characteristics shall be as specified in 22.108, except for the
impulse repetition rate.
If the impulse repetition rate is greater than 1,34 Hz, the discharge energy per second into a
load consisting of a non-inductive resistor of 500 Ω shall not exceed 2,5 J/s for a period
exceeding 3 min before the energizer is rendered inoperative by a non-self-resetting
protective device .
The temperature rises of the windings shall not exceed the values shown in Table 8.
19.101 Energizers are subjected to each of the following conditions in turn, while being
supplied with the voltage specified in 11.5, including those associated with such other fault
conditions that are an actual consequence of the condition chosen:
–t h e energizer is placed in its most unfavourable position even if it is not likely to be
installed in this position in normal use;
– parts intended for adjusting the energizer , other than those that are adjustable from the
outside of the energizer without the aid of a tool , are adjusted to their most unfavourable
position, even if these parts are not intended to be adjusted by the user, unless they are
effectively sealed against further adjustment;
– the earthing conductor is removed from the earthing terminal of the fence circuit and
connected to any other output terminal;
– the output terminals are short-circuited;
– switches, relay-contacts and the like, that form part of the impulse device, are
short-circuited or open-circuited, whichever is the more unfavourable;
– fuses that are accessible without the aid of tools , series spark gaps in the fence circuit ,
discharging valves and thermal relays are short-circuited;
– except for electronic circuits , any creepage distance or clearance between live parts
of different potential that is less than 5 mm for the fence circuit , or 2 mm or less for other
circuits, is short-circuited, and any unlocked connection is loosened;
– the switching speed of an electronic component used as the major pulse switching
device shall be varied in the range 0,1 Hz to twice the rated frequency , in approximately
a 1:2:5 progression sequence over three decades, by referencing the gate signal of this
device to the voltage across it using an external independent control.
NOTE Details of a simple comparator circuit that has been found suitable for controlling the switching speed of
the major pulse switching device are given in Annex AA.
19.102 Types A, C and D energizers are subjected to each of the following conditions in
turn, while being supplied with the voltage specified in 11.5:
– with the energizer connected for battery supply, terminals for the connection of the battery
having an indication of polarity are connected to the opposite polarity, unless such a
connection is unlikely to occur in normal use;
– with the energizer connected for mains operation, terminals for the connection of the
battery supply are connected to the most unfavourable load, including a short circuit.
19.103 Type B energizers connected for mains supply with battery charge operation are
subjected to each of the following conditions in turn, while being supplied with the voltage
specified in 11.5:
– the terminals for the connection of the battery having an indication of polarity are
connected to the opposite polarity, unless such a connection is unlikely to occur
in normal use;
– the terminals for the connection of the battery supply are connected to the most
unfavourable load, including a short circuit.
60335-2-76 IEC:2002(E) – 21 –
19.104 Battery-operated energizers and type B energizers connected for battery supply
are supplied with the voltage specified in 11.5. The supply terminals having an indication of
polarity are connected to the opposite polarity, unless such a connection is unlikely to occur in
normal use.
20 Stability and mechanical hazards
This clause of Part 1 is not applicable.
21 Mechanical strength
This clause of Part 1 is applicable except as follows.
21.101 The energizer shall withstand the effect of being dropped.
Compliance is checked by the following test.
The energizer is bolted centrally to a board 1 000 mm ± 5 mm long by 225 mm ± 5 mm wide
and approximately 25 mm thick. The board is supported at each end on a rigid table by baulks
of timber of such a size that the energizer is held clear of the table surface. One end of the
board is lifted through a distance of 200 mm ± 5 mm and allowed to fall freely. The test is
repeated 20 times. This procedure is then repeated with the board placed on each of its other
longitudinal edges in turn.
After the test, the energizer shall show no damage within the meaning of this standard.
22 Construction
This clause of Part 1 is applicable except as follows.
22.31 Modification:
The requirement applies only to mains-operated energizers and battery-operated energizers
suitable for connection to the mains .
22.32 Modification:
The requirement applies only to mains-operated energizers and battery-operated energizers
suitable for connection to the mains .
22.101 For mains-operated energizers and battery-operated energizers suitable for
connection to the mains , internal connections shall be so fixed or protected, and energizers
shall be so designed that, even in the event of the loosening or breaking of wires, a
conductive connection cannot be formed between the mains supply and the fence circuit ,
and no other hazardous condition shall arise.
The input winding and the output windings of transformers used to isolate the fence circuit
from the supply circuit shall be separated by an insulating barrier, and the construction shall
be such that there is no possibility of any connection between these windings, either directly
or indirectly through other metal parts.
In particular, precautions shall be taken to prevent
– displacement of input or output windings, or the turns thereof;
– 22 – 60335-2-76 IEC:2002(E)
– undue displacement of parts of windings, or of internal wiring, in the event of a rupture or
loosening of connections.
Compliance is checked by inspection and by the tests of the other clauses of this standard.
NOTE 1 Isolation between the mains and the fence circuit may be achieved by the incorporation of a
double-wound transformer situated either in the input circuit or in the fence circuit . If such transformers are
incorporated in both circuits, at least one of these transformers should provide the required degree of isolation.
NOTE 2 Circuits connected between the input terminals and the primary side of the transformer providing
the required degree of isolation are considered to be connected to the mains, and circuits connected between the
output terminals and the secondary side of this transformer are considered to belong to the fence circuit .
NOTE 3 Examples of constructions that comply with the requirements of this subclause for windings are
– windings on separate spools of adequate insulating material, rigidly fixed with respect to each other and to the
core of the transformer;
– windings on a single spool with a partition wall, both of adequate insulating material, provided that the spool
and partition wall are pressed or moulded in one piece, or that, in the case of a pushed-on partition wall, there
is an intermediate sheath or covering over the joint between the spool and the partition wall;
– concentric windings on cheekless formers, provided that
• each layer of the winding is interleaved with adequate insulating material projecting beyond the end turns
of each layer,
• one or more separate sheets of insulating material of adequate thickness are provided between the input
winding and the output windings, and
• the windings are impregnated with a hard-baked or other suitable material that fully penetrates the
interstices and effectively seals off the end turns.
NOTE 4 It is not to be expected that two independent fixings will become loose at the same time.
22.102 For mains-operated energizers and battery-operated energizers suitable for
connection to the mains , transformers in the fence circuit shall be placed in a separate
compartment. This compartment shall not contain any part that is, or can come, in contact
with the mains, with the exception of the input winding of the transformer. The bushings
referred to in 22.105 shall be in the wall of this compartment.
Compliance is checked by inspection and by the tests of the other clauses of this standard.
22.103 For metal-encased class II energizers , the output terminals shall be placed so that
external conductors connected to these terminals are not likely to come into contact with the
enclosure.
Compliance is checked by inspection.
22.104 Energizers shall be so designed that
– the conductors for the connection of the fence and the earth electrode can be easily
connected;
– it is possible to actuate switches and other controls, if this is necessary in normal use,
after the energizer has been mounted and connected to the supply, without opening or
removing any enclosure that provides protection against harmful ingress of water or
unintended electric shock.
Compliance is checked by inspection.
22.105 For mains-operated energizers and battery-operated energizers suitable for
connection to the mains , any assembly gap in supplementary insulation shall not be co-
incidental with any such gap in basic insulation , neither shall any such gap in reinforced
insulation give straight access to live parts .
Compliance is checked by inspection.
60335-2-76 IEC:2002(E) – 23 –
22.106 In types A, B and C energizers , terminals for the connection of the battery and
other metal parts in a battery compartment that become accessible when replacing batteries,
even with the aid of a tool , shall be insulated from live parts by double insulation or
reinforced insulation .
In type D energizers and battery-operated energizers , parts in a battery compartment
that become accessible when replacing batteries, even with the aid of a tool , shall not be
live parts .
Compliance is checked by inspection, measurement and by the tests specified for double
insulation or reinforced insulation .
22.107 Battery-operated energizers and battery-operated energizers suitable for
connection to the mains shall be provided with means to prevent the user from being
subjected to an electric shock due to the energizer output voltage, when connecting a battery
to the energizer .
Compliance is checked by inspection.
NOTE Examples of such means are:
– a switch that isolates the terminals for the connection of the battery;
– a control that enables the output voltage to be reduced to zero;
– insulated crocodile clips or similar devices.
22.108 Energizer output characteristics shall be such that
– the impulse repetition rate shall not exceed 1 Hz;
–t h e impulse duration of the impulse in the 500 Ω component of the standard load shall
not exceed 10 ms;
–f o r energy limited energizers the energy/impulse in the 500 Ω component of the
standard load shall not exceed 5 J;
–f o r current limited energizers the output current in the 500 Ω component of the
standard load shall not exceed for
• an impulse duration of greater than 0,1 ms, the value specified by the characteristic
limit line detailed in Figure 102;
• an impulse duration of less than 0,1 ms, 15 700 mA.
Compliance is checked by measurement when the energizer is supplied with the voltage
in 11.5, the energizer being operated under conditions of normal operation but with the
standard load connected to its output terminals. When measuring the impulse repetition rate
the standard load is not connected.
The measurements are made using a measuring arrangement with an input impedance
consisting of a non-inductive resistance of not less than 1 M Ω in parallel with a capacitance of
not more than 100 pF.
22.109 If the energizer is provided with more than one fence circuit , the output
characteristics shall be within the limits specified in 22.108 for any possible connection of
the fence circuits .
The impulses for the individual sets of output terminals shall be synchronized and
–t h e impulse duration shall not exceed the value specified in 22.108;
– the impulse repetition rate shall not exceed the value specified in 22.108;
for any possible combination of individual impulses.
Compliance is checked by the measurements specified in 22.108
– 24 – 60335-2-76 IEC:2002(E)
22.110 For types A and B energizers that have terminals for the connection of the battery,
the no-load d.c. output voltage shall not exceed 42,4 V.
Compliance is checked by measuring the no-load d.c. output voltage appearing at the
terminals for the connection of the battery when the energizer is connected for mains supply
and is supplied at rated voltage .
22.111 The peak value of the output voltage, U0, shall be measured and recorded to enable
the tests and measurements of 14.102, 14.103, 14.104 and 16.3 to be carried out.
Compliance is checked by the following test.
The peak value of the output voltage is measured, using a measuring arrangement described
in 22.108 with the energizer supplied with the voltage in 11.5 under conditions of normal
operation , but with a load connected to the output terminals consisting of a capacitor having
a capacitance that can be varied between 0 and 200 nF in steps of approximately 10 nF.
23 Internal wiring
This clause of Part 1 is applicable except as follows.
23.7 Replacement:
For mains-operated energizers and battery-operated energizers suitable for connection
to the mains , conductors identified by the colour combination green/yellow shall not be used.
Compliance is checked by inspection.
24 Components
This clause of Part 1 is applicable.
25 Supply connection and external flexible cords
This clause of Part 1 is applicable except as follows.
25.1 Addition:
Type D energizers shall be provided with a non-detachable flexible cord with connecting
means that are not suitable for connection to the mains, or an appliance inlet, having at least
the same degree of protection against moisture as required for the energizer , that is not
compatible with appliance couplers complying with the standard sheets of IEC 60320.
Compliance is checked by inspection.
25.5 Addition:
The flexible leads or flexible cord used to connect the battery in battery-operated energizers
shall be assembled with the energizer by a type X attachment .
25.7 Replacement:
Supply cords , other than the flexible leads or flexible cord connecting an external battery or
battery box with an energizer , shall not be lighter than
60335-2-76 IEC:2002(E) – 25 –
– ordinary polyvinyl chloride sheathed cord (code designation 60227 IEC 53);
– ordinary polychloroprene sheathed cord (code designation 60245 IEC 57).
The ordinary polychloroprene sheathed cord shall be used where, for climatic reasons, the
ordinary polyvinyl chloride sheathed cord is not suitable.
Compliance is checked by inspection.
25.8 Addition:
The conductors in flexible leads or flexible cords used to connect the battery in battery-
operated energizers shall have a nominal cross-sectional area of not less than 0,75 mm 2.
25.13 Addition:
This requirement is not applicable to the flexible leads or flexible cord connecting external
batteries or a battery box with an energizer .
25.23 Addition:
In types A, B, C, D and battery-operated energizers , if the battery is placed in a separate
box, the flexible lead or flexible cord connecting the box with the energizer is considered to
be an interconnection cord .
25.101 Battery-operated energizers shall have suitable means for connection of the
battery. If the type of battery is marked on the energizer , the means of connection shall be
suitable for this type of battery.
Compliance is checked by inspection.
26 Terminals for external conductors
This clause of Part 1 is applicable except as follows.
26.1 Addition:
The second sentence of the requirement does not apply to the energizer output terminals.
26.5 Addition:
Terminal devices in an energizer for the connection of the flexible leads or flexible cord with
type X attachment connecting an external battery or battery box shall be so located or
shielded that there is no risk of accidental connection between supply terminals.
26.9 Addition:
The requirement does not apply to the energizer output terminals.
26.101 Output terminals shall be so designed or located that it is not possible to connect the
fence or the earth electrode to the energizer by means of a plug that is designed for
connection to a socket-outlet for mains supply.
Compliance is checked by inspection and by manual test.
– 26 – 60335-2-76 IEC:2002(E)
26.102 Output terminals shall be fixed so that they will not work loose when external
conductors are connected or disconnected.
Compliance is checked by inspection and by manual test.
26.103 Devices for clamping the conductors connecting the fence or the earth electrode to
the energizer shall not serve to fix any other component.
Compliance is checked by inspection.
27 Provision for earthing
This clause of Part 1 is applicable except as follows.
27.1 Addition:
NOTE 101 In class II energizers provision may be made for connecting at least one of the output terminals to the
earth electrode .
28 Screw and connections
This clause of Part 1 is applicable.
29 Clearances, creepage distances and solid insulation
This clause of Part 1 is applicable except as follows.
Addition:
Compliance is also checked by the requirements and measurements of 29.101.
29.101 Clearances between
– live parts of the fence circuit and other metal parts, or
– metal enclosures and other metal parts of the energizer , including foil wrapped around the
supply cord inside inlet bushings, cord guards, cord anchorages and similar parts,
shall not be less than 25 mm.
The clearances between the poles of the supply circuit in battery-operated energizers shall
be not less than 2 mm, when the energizer is fitted with conductors as in normal use.
Compliance is checked by measurement.
30 Resistance to heat and fire
This clause of Part 1 is applicable except as follows.
30.2.1 Modification:
The glow-wire test is made at a temperature of 650 °C.
30.2.2 Not applicable.
60335-2-76 IEC:2002(E) – 27 –
31 Resistance to rusting
This clause of Part 1 is replaced by the following.
The enclosure of metal-encased class II energizers shall be adequately protected against
corrosion.
Compliance is checked by the salt mist test of IEC 60068-2-5. Severity 2 is applicable.
Before the test, coatings are scratched by means of a hardened steel pin, the end of which
has the form of a cone with an angle of 40 o. Its tip is rounded with a radius of
0,25 mm ± 0,02 mm. The pin is loaded so that the force exerted along its axis is 10 N ± 0,5 N.
The scratches are made by drawing the pin along the surface of the coating at a speed of
approximately 20 mm/s. Five scratches are made at least 5 mm apart and at least 5 mm from
the edge.
After the test, the appliance shall not have deteriorated to such an extent that compliance with
this standard is impaired. The coating shall not have broken and shall not have loosened from
the metal surface.
32 Radiation, toxicity and similar hazards
This clause of Part 1 is applicable.
– 28 – 60335-2-76 IEC:2002(E)
Connection for Connection for
mains operation battery operation
Key
S = supply mains
Ch = battery charger circuit
IG = impulse generating circuit
B.Ch = separate battery charger
= battery
F= fence connection
Figure 101 – Schematic examples of the different types of battery-operated
energizers suitable for connection to the mains
IEC 425/97
60335-2-76 IEC:2002(E) – 29 –
0,01
0,1
1
10
100
100 1 000 10 000 100 000
Output current (mA)
Impulse duration (ms)
IEC 322/99
NOTE The equation of the line relating impulse duration (ms) to output current (mA) for 1 000 mA < output
current < 15 700 mA, is given by impulse duration = 41,885 × 103 × (output current )–1,34
Figure 102 – Current limited energizer characteristic limit line
– 30 – 60335-2-76 IEC:2002(E)
Annexes
The Annexes of Part 1 are applicable except as follows.
Annex A
(informative)
Routine tests
This Annex of Part 1 is applicable except as follows.
A.2 Electric strength test
Addition:
For mains-operated energizers and battery-operated energizers suitable for connection
to the mains , an electric strength test is carried out between the mains supply circuit and the
fence circuit , the test voltage being 10 000 V, a.c., 50 Hz or 60 Hz for 1 s.
A.3 Functional test
Addition:
The energizer output characteristic shall be checked by operating the energizer at rated
voltage with a 500 Ω load connected across the fence terminals.
The energizer output characteristic shall be such that
− the impulse repetition rate shall not exceed 1 Hz;
− the impulse duration of the impulse shall not exceed 10 ms;
− for energy limited energizers , the energy/impulse shall not exceed 5 J;
− for current limited energizers , the output current shall not exceed
• the value specified by the characteristic limit line detailed in Figure 102;
• for an impulse duration of less than 0,1 ms, 15 700 mA.
60335-2-76 IEC:2002(E) – 31 –
Annex B
(normative)
Appliances powered by rechargeable batteries
This Annex of Part 1 is applicable except as follows.
Addition:
The modifications to 3.19, 11.7, 19 and 30.2 are not applicable.
– 32 – 60335-2-76 IEC:2002(E)
Annex AA
(informative)
Circuit for the independent control of the switching speed
of the major pulse-switching device
A suitable circuit for external independent control of the switching speed of semiconductor
devices used as the major pulse-switching device in the energizer , in accordance with the
eighth dashed item of 19.101, is shown in Figure AA.1.
The circuit is used to reference the gate signal of the major pulse-switching device to the
voltage across this device so that it can be triggered at the same point in the charging cycle.
The reference voltage should be of such a value that the comparator is adjustable over the
whole range of the energizer charging voltage, thereby allowing the switching speed to be set
at any desired frequency.
The input impedance of the comparator circuit should be such that it does not influence the
results of the test.
Vc
Vr
Sg
Op
Pot
Key
Vc = Charging voltage
Vr = Reference voltage
Sg = Gate signal
Pot = Switching speed adjustor
Op = Comparator
Figure AA.1 – Circuit for the independent control of the switching speed
of the major pulse-switching device
60335-2-76 IEC:2002(E) – 33 –
Annex BB
(normative)
Instructions for installation and connection of electric fences
BB.1 Requirements for electric animal fences
Electric animal fences and their ancillary equipment shall be installed, operated and
maintained in a manner that minimizes danger to persons, animals or their surroundings.
Electric animal fence constructions that are likely to lead to the entanglement of animals or
persons shall be avoided.
An electric animal fence shall not be supplied from two separate energizers or from
independent fence circuits of the same energizer .
For any two separate electric animal fences , each supplied from a separate energizer
independently timed, the distance between the wires of the two electric animal fences shall
be at least 2 m. If this gap is to be closed, this shall be effected by means of electrically non-
conductive material or an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an energizer .
A non-electrified fence incorporating barbed wire or razor wire may be used to support one or
more off-set electrified wires of an electric animal fence . The supporting devices for the
electrified wires shall be constructed so as to ensure that these wires are positioned at a
minimum distance of 150 mm from the vertical plane of the non-electrified wires. The barbed
wire and razor wire shall be earthed at regular intervals.
Follow the energizer manufacturer’s recommendations regarding earthing.
A distance of at least 10 m shall be maintained between the energizer earth electrode and
any other earthing system connected parts such as the power supply system protective earth
or the telecommunication system earth.
Connecting leads that are run inside buildings shall be effectively insulated from the earthed
structural parts of the building. This may be achieved by using insulated high voltage cable.
Connecting leads that are run underground shall be run in conduit of insulating material or
else insulated high voltage cable shall be used. Care must be taken to avoid damage to the
connecting leads due to the effects of animal hooves or tractor wheels sinking into the
ground.
Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
Connecting leads and electric animal fence wires shall not cross above overhead power or
communication lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a crossing
cannot be avoided it shall be made underneath the power line and as nearly as possible at
right angles to it.
– 34 – 60335-2-76 IEC:2002(E)
If connecting leads and electric animal fence wires are installed near an overhead power
line, the clearances shall not be less than those shown in Table BB1.
Table BB1 – Minimum clearances from power lines for electric animal fences
Power line voltage
V
Clearance
m
≤ 1 000
> 1 000 and ≤ 33 000
> 33 000
3
4
8
If connecting leads and electric animal fence wires are installed near an overhead power
line, their height above the ground shall not exceed 3 m
This height applies to either side of the orthogonal projection of the outermost conductors of
the power line on the ground surface, for a distance of
– 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
– 15 m for power lines operating at a nominal voltage exceeding 1 000 V.
Electric animal fences intended for deterring birds, household pet containment or training
animals such as cows need only be supplied from low output energizers to obtain satisfactory
and safe performance.
In electric animal fences intended for deterring birds from roosting on buildings, no electric
fence wire shall be connected to the energizer earth electrode . A warning sign shall be fitted
to every point where persons may gain ready access to the conductors.
Where an electric animal fence crosses a public pathway, a non-electrified gate shall be
incorporated in the electric animal fence at that point or a crossing by means of stiles shall
be provided. At any such crossing, the adjacent electrified wires shall carry warning signs.
Any part of an electric animal fence that is installed along a public road or pathway shall be
identified at frequent intervals by warning signs securely fastened to the fence posts or firmly
clamped to the fence wires.
The size of the warning sign shall be at least 100 mm × 200 mm.
The background colour of both sides of the warning sign shall be yellow. The inscription on
the sign shall be black and shall be either
– the symbol of Figure BB1, or
– the substance of “CAUTION: Electric animal fence ”.
The inscription shall be indelible, inscribed on both sides of the warning sign and have a
height of at least 25 mm.
Ensure that all mains-operated, ancillary equipment connected to the electric animal fence
circuit provides a degree of isolation between the fence circuit and the supply mains
equivalent to that provided by the energizer .
NOTE 1 Ancillary equipment that complies with the requirements relating to isolation between the fence circuit
and the supply mains in Clauses 14, 16 and 29 of the standard for the electric fence energizer is considered to
provide an adequate level of isolation.
60335-2-76 IEC:2002(E) – 35 –
Protection from the weather shall be provided for the ancillary equipment unless this
equipment is certified by the manufacturer as being suitable for use outdoors, and is of a type
with a minimum degree of protection IPX4.
BB.2 Requirements for electric security fences
Electric security fences and their ancillary equipment shall be installed, operated and
maintained in a manner that minimizes danger to persons, and reduces the risk of persons
receiving an electric shock unless they attempt to penetrate the physical barrier , or are in
the secure area without authority.
Electric security fence constructions that are likely to lead to the entanglement of persons
shall be avoided.
Gates in electric security fences shall be capable of being opened without the person
receiving an electric shock.
An electric security fence shall not be supplied from two separate energizers or from
independent fence circuits of the same energizer .
For any two separate electric security fences , each supplied from a separate energizer
independently timed, the distance between the wires of the two electric security fences shall
be at least 2,5 m. If this gap is to be closed, this shall be effected by means of electrically
non-conductive material or an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an energizer .
Follow the energizer manufacturer’s recommendations regarding earthing.
The distance between any electric security fence earth electrode and other earth systems
shall be not less than 2 m, except when associated with a graded earth mat.
NOTE 1 Where possible the distance between any electric security fence earth electrode and other earth
systems should preferably be at least 10 m.
Exposed conductive parts of the physical barrier shall be effectively earthed.
Where an electric security fence passes below bare power line conductors, the highest
metallic element shall be effectively earthed for a distance of not less than 5 m on either side
of the crossing point.
Connecting leads that are run inside buildings shall be effectively insulated from the earthed
structural parts of the building. This may be achieved by using insulated high voltage cable.
Connecting leads that are run underground shall be run in conduit of insulating material or
else insulated high voltage cable shall be used. Care must be taken to avoid damage to the
connecting leads due to the effects of vehicle wheels sinking into the ground.
Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
Connecting leads and electric security fence wires shall not cross above overhead power
or communication lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a crossing
cannot be avoided it shall be made underneath the power line and as nearly as possible at
right angles to it.
– 36 – 60335-2-76 IEC:2002(E)
If connecting leads and electric security fence wires are installed near an overhead power
line, the clearances shall not be less than those shown in Table BB2.
Table BB2 – Minimum clearances from power lines for electric security fences
Power line voltage
V
Clearance
m
≤1 000
>1 000 and ≤33 000
>33 000
3
4
8
If connecting leads and electric security fence wires are installed near an overhead power
line, their height above the ground shall not exceed 3 m
This height applies to either side of the orthogonal projection of the outermost conductors of
the power line on the ground surface, for a distance of
– 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
– 15 m for power lines operating at a nominal voltage exceeding 1 000 V.
A spacing of 2,5 m shall be maintained between uninsulated electric security fence
conductors or uninsulated connecting leads supplied from separate energizers . This
spacing may be less where conductors or connecting leads are covered by insulating
sleeving, or consist of insulated cables rated to at least 10 kV.
This requirement need not apply where the separately energized conductors are separated by
a physical barrier that does not have any openings greater than 50 mm.
A vertical separation of not less than 2 m shall be maintained between pulsed conductors
fed from separate energizers .
Electric security fences shall be identified by prominently placed warning signs.
The warning signs shall be legible from the secure area and the public access area .
Each side of the electric security fence shall have at least one warning sign.
Warning signs shall be placed
– at each gate;
– at each access point;
– at intervals not exceeding 10 m;
– adjacent to each sign relating to chemical hazards for the information of the emergency
services.
Any part of an electric security fence that is installed along a public road or pathway shall
be identified at frequent intervals by warning signs securely fastened to the fence posts or
firmly clamped to the fence wires.
The size of the warning sign shall be at least 100 mm × 200 mm.
60335-2-76 IEC:2002(E) – 37 –
The background colour of both sides of the warning sign shall be yellow. The inscription on
the sign shall be black and shall be either
– the symbol of Figure BB1, or
– the substance of “CAUTION: Electric security fence ”.
The inscription shall be indelible, inscribed on both sides of the warning sign and have a
height of at least 25 mm.
Ensure that all mains operated, ancillary equipment connected to the electric security fence
circuit provides a degree of isolation between the fence circuit and the supply mains
equivalent to that provided by the energizer .
NOTE 2 Ancillary equipment that complies with the requirements relating to isolation between the fence circuit
and the supply mains in Clauses 14, 16 and 29 of the standard for the electric fence energizer is considered to
provide an adequate level of isolation.
Mains supply wiring shall not be installed in the same conduit as signalling leads associated
with the electric security fence installation.
Protection from the weather shall be provided for the ancillary equipment unless this
equipment is certified by the manufacturer as being suitable for use outdoors, and is of a type
with a minimum degree of protection IPX4.
– 38 – 60335-2-76 IEC:2002(E)
Figure BB1 – Symbol for warning sign
60335-2-76 IEC:2002(E) – 39 –
Annex CC
(informative)
Installation of electric security fences
CC.1 General
An electric security fence should be installed so that, under normal conditions of operation,
persons are protected against inadvertent contact with pulsed conductors .
NOTE 1 This requirement is primarily intended to establish that a desirable level of safety is present or is being
maintained in the physical barrier .
NOTE 2 When selecting the type of physical barrier , the likely presence of young children should be a factor in
considering the size of openings.
CC.2 Location of electric security fence
The electric fence should be separated from the public access area by means of a physical
barrier .
Where an electric fence is installed in an elevated position, such as a window or skylight, the
physical barrier may be less than 1,5 m high where it covers the whole of the electric fence .
CC.3 Prohibited zone for pulsed conductors
Pulsed conductors shall not be installed within the shaded zone shown in Figure CC1.
NOTE 1 Where an electric security fence is planned to run close to a site boundary, the relevant government
authority should be consulted before installation begins.
NOTE 2 Typical electric security fence installations are shown in Figure CC2 and Figure CC3.
CC.4 Separation between electric fence and physical barrier
Where a physical barrier is installed in compliance with CC.3 at least one dimension in any
opening should be not greater than 130 mm and the separation between the electric fence
and the physical barrier should be
– within the range of 100 mm to 200 mm or greater than 1 000 mm where at least one
dimension in each opening in the physical barrier is not greater than 130 mm;
– greater than 1 000 mm where any opening in the physical barrier has all dimensions
greater than 50 mm;
– less than 200 mm or greater than 1 000 mm where the physical barrier does not have any
openings.
NOTE 1 These restrictions are intended to reduce the possibility of persons making inadvertent contact with the
pulsed conductors and to prevent them from becoming wedged between the electric fence and the physical
barrier , thereby being exposed to multiple shocks from the energizer .
NOTE 2 The separation is the perpendicular distance between the electric fence and the physical barrier .
CC.5 Prohibited mounting
Electric fence conductors should not be mounted on a support used for any overhead power line.
– 40 – 60335-2-76 IEC:2002(E)
CC.6 Operation of electric security fence
The conductors of an electric fence should not be energized unless all authorized persons,
within or entering the secure area , have been informed of its location.
Where there is a risk of persons being injured by a secondary cause, appropriate additional
safety precautions should be taken.
NOTE An example of a secondary cause is where a person may be expected to fall from a surface if contact is
made with pulsed conductors .
45°
A
1 500 mm
B
Key
A = Secure area
B = Public access area
Physical barrier
Prohibited Prohibited area
Electric security fence
Figure CC1 – Prohibited area for pulse conductors
60335-2-76 IEC:2002(E) – 41 –
A
1 500 mm min.
B
1 2
A
1 500 mm min.
B
1 2
A
1 500 mm min.
B
1
2
A
1 500 mm min.
B
1 2
C
A
1 500 mm min.
B
12
Key
A = Secure area
B = Public access area
C = Barrier where required
1 = Electric security fence
2 = Physical barrier
Figure CC2 – Typical constructions where an electric
security fence is exposed to the public
– 42 – 60335-2-76 IEC:2002(E)
E
2
B
A
1
C
C
1
A B
D
2
Key
A = Secure area
B = Public access area
C = Barrier where required
D = Glass window pane
E = Skylight in roof
1 = Electric security fence
2 = Physical barrier
Figure CC3 – Typical fence constructions where the electric
security fence is installed in windows and skylights
60335-2-76 IEC:2002(E) – 43 –
Bibliography
The bibliography of Part 1 is applicable except as follows.
Addition:
IEC 60335-2-86, Household and similar electrical appliances – Safety – Part 2-86: Particular
requirements for electric fishing machines
IEC 60335-2-87, Household and similar electrical appliances – Safety – Part 2-87: Particular
requirements for electric animal stunning equipment
___________
Standards Survey
The IEC would like to offer you the best quality standards possible. To make sure that we
continue to meet your needs, your feedback is essential. Would you please take a minute
to answer the questions overleaf and fax them to us at +41 22 919 03 00 or mail them to
the address below. Thank you!
Customer Service Centre (CSC)
International Electrotechnical Commission
3, rue de Varembé
1211 Genève 20
Switzerland
or
Fax to: IEC/CSC at +41 22 919 03 00
Thank you for your contribution to the standards-making process.
Non affrancare
No stamp required
Nicht frankieren
Ne pas affranchir
A Prioritaire
RÉPONSE PAYÉE
SUISSE
Customer Service Centre (CSC)
International Electrotechnical Commission
3, rue de Varembé
1211 GENEVA 20
Switzerland
Q1 Please report on ONE STANDARD and
ONE STANDARD ONLY . Enter the exact
number of the standard: (e.g. 60601-1-1)
.............................................................
Q2 Please tell us in what capacity(ies) you
bought the standard (tick all that apply).
I am the/a:
purchasing agent /G52
librarian /G52
researcher /G52
design engineer /G52
safety engineer /G52
testing engineer /G52
marketing specialist /G52
other.....................................................
Q3 I work for/in/as a:
(tick all that apply)
manufacturing /G52
consultant /G52
government /G52
test/certification facility /G52
public utility /G52
education /G52
military /G52
other.....................................................
Q4 This standard will be used for:
(tick all that apply)
general reference /G52
product research /G52
product design/development /G52
specifications /G52
tenders /G52
quality assessment /G52
certification /G52
technical documentation /G52
thesis /G52
manufacturing /G52
other.....................................................
Q5 This standard meets my needs:
(tick one)
not at all /G52
nearly /G52
fairly well /G52
exactly /G52
Q6 If you ticked NOT AT ALL in Question 5
the reason is: (tick all that apply)
standard is out of date /G52
standard is incomplete /G52
standard is too academic /G52
standard is too superficial /G52
title is misleading /G52
I made the wrong choice /G52
other ....................................................
Q7 Please assess the standard in the
following categories, using
the numbers:
(1) unacceptable,
(2) below average,
(3) average,
(4) above average,
(5) exceptional,
(6) not applicable
timeliness.............................................
quality of writing....................................
technical contents.................................
logic of arrangement of contents ..........
tables, charts, graphs, figures...............
other ....................................................
Q8 I read/use the:
(tick one)
French text only /G52
English text only /G52
both English and French texts /G52
Q9 Please share any comment on any
aspect of the IEC that you would like
us to know:
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
ISBN 2-8318-6501-8
-:HSMINB=][ZUVU:
ICS 65.040.99
Typeset and printed by the IEC Central Office
GENEVA, SWITZERLAND
MODEL ELECTRIC FENCE ORDINANCE
A. The construction and use of electric fences shall be allowed in the city only as
provided in this section, subject to the following standards:
1. IEC Standard 60335-2-76: Unless otherwise specified herein, electric fences shall
be constructed or installed in conformance with the specifications set forth in
International Electro technical Commission (IEC) Standard No. 60335-2-76.
2. Electrification:
(a) The energizer for electric fences must be driven by a commercial storage
battery not to exceed 12 volts DC. The storage battery is charged primarily
by a solar panel. However, the solar panel may be augmented by a
commercial trickle charger.
(b) The electric charge produced by the fence upon contact shall not exceed
energizer characteristics set forth in paragraph 22.108 and depicted in
Figure 102 of IEC Standard No. 60335-2-76.
3. Perimeter fence or wall:
(a) No electric fence shall be installed or used unless it is completely
surrounded by a non-electrical fence or wall that is not less than five feet.
4. Location: Electric fences shall be permitted on any non-residential outdoor
storage areas.
5. Height: Electric fences shall have a height of 10 feet (or 2 feet higher than the
perimeter fence whichever is higher).
6. Warning signs: Electric fences shall be clearly identified with warning signs that
read: "Warning-Electric Fence" at intervals of not less than sixty feet.
7. Electric fences shall be governed and regulated under burglar alarm regulations
and permitted as such.
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: *10
CONSENT: REGULAR: X WORK SESSION: CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: Substantial Amendment #3 for the CDBG program and the receipt of the Community Development
Block Grant Coronavirus Aid, Relief and Economic Security Act (CARES ACT) (CDBG-CV) Round 3 Program
Funds
KEY ELEMENTS:
___Economic Development ___Excellent Government _X_ Natural and Built Environment _X Safe Community _X _Vibrant Community
RECOMMENDATION: Adopt a resolution approving the submission of Substantial Amendment #3 to the
Program Year (PY) 2019 Annual Action Plan (Fiscal Year [FY] 2021) for the Community Development Block
Grant (CDBG) and HOME Program to the U. S. Department of Housing and Urban Development (HUD); and
amend the FY 2021 Community Development Block Grant budget with resources of $389,143 from the
Community Development Block Grant Coronavirus Aid, Relief And Economic Security Act (CARES ACT)
(CDBG-CV) Round 3 Program Funds.
SUMMARY: The City has received notification from HUD for an additional special allocation of
Community Development Block Grant funds to be used to prevent, prepare for, and respond to the
coronavirus (COVID-19). This allocation was authorized by HUD on September 11, 2020 and constituted
a third round of CDBG-CV funds for states and local governments. These funds are an extension of the
Coronavirus Aid, Relief, and Economic Security Act (CARES Act), which was signed by President Trump
on March 27, 2020, to respond to the growing effects of this historic public health crisis. Lynchburg’s
allocation is $389,143.
For receipt of these funds, in accordance with HUD regulations; the City is required to submit a
"Substantial Amendment" to its HUD PY 2019 CDBG Annual Action Plan. This Amendment is to include
projects that will prevent, prepare for, and respond to the Coronavirus (COVID-19).
Utilizing the CDBG application process and the guidelines from HUD for eligible projects/activities, City staff
solicited and accepted applications for the CDBG-CV funds. Attached is a summary of the applications
received from local nonprofits and City departments. These projects/activities are eligible according to the
HUD guidelines and will benefit the citizens of Lynchburg that have been or will be affected by COVID-19.
In accordance with the CDBG Citizen Participation Plan’s “In the Event of an Emergency” section, the public
comment period was reduced to five (5) days as approved by HUD. The Community Development Advisory
Committee (CDAC) did not conduct a public meeting regarding the submitted projects. However, the
applications were provided to CDAC with the opportunity to comment on the proposed projects. The CDAC
comments provided to City staff supported the funding of the proposed projects. The following lists of projects
are recommended for funding by City staff:
CDBG-CV PROJECTS PROPOSED FOR FUNDING:
City Administration $18,448
Feeding the Homebound (Meals on Wheels of Greater Lynchburg) $46,500
Emergency Housing Assistance (Lynchburg Community Action Group) $75,000
Reducing Evictions through Legal Aid (Virginia Legal Aid Society) $30,000
Domestic Violence Prevention Program (YWCA of Central Virginia) $6,680
Summer Lunch & Play Program (City’s Department of Parks and Recreation) $20,000
Shelter Program and Apparatus Air Purifier Project (City’s Fire Department) $192,515
Total CDBG-CV ROUND 3 $389,143
The public was notified of the public hearing through a public notice advertisement published in The News and
Advance on April 5 and through various sources of social media. Following the public hearing, City Council
approved all of the projects except for the “Reducing Evictions through Legal Aid” request. That item was
tabled and staff was asked to provide additional information (i) from Virginia Legal Aid Society on additional
federal and/or state funding they have received to reduce evictions and (ii) from the Lynchburg Redevelopment
and Housing Authority on the level of communication and partnership the agency has with Virginia Legal Aid
Society. The response from Virginia Legal Aid Society is attached and the Executive Directors of both agencies
plan to attend the City Council meeting.
PRIOR ACTION(S): City Council conducted a public hearing on April 13, 2021.
FISCAL IMPACT: The FY 2021 (HUD PY 2019) Community Development Block Grant fund will be
increased by $389,143
CONTACT(S): Melva Walker, Grants Manager, 455-3916;
Kent White, Interim Deputy City Manager/Director of Community Development, 455-3919
ATTACHMENT(S): Resolution
Attachment A – Summary of CDBG-CV Applications
Attachment B – CDBG-CV Worksheet
Attachment C – Virginia Legal Aid Society Background Information
REVIEWED BY: klw
057A
RESOLUTION: #R-21-024
BE IT RESOLVED that the HUD Program Year 2019 (FY 2021) Community Development Block Grant (CDBG)
Annual Action Plan Substantial Amendment #3 is amended incorporating the proposed CDBG-CV Round 3
projects and is hereby approved for submittal to the U. S. Department of Housing and Urban Development
(HUD); and
BE IT FURTHER RESOLVED that the FY 2021 Community Development Block Grant budget (HUD Program
Year 2019) is amended and $389,143 is appropriated with resources from the Community Development Block
Grant Coronavirus Aid, Relief and Economic Security Act (CARES ACT) (CDBG-CV-Round 3).
Introduced: April 13, 2021 Adopted:
Certified: ____________________________
Clerk of Council
ATTACHMENT A
1
Summary of Fiscal Year (FY) 2021, Program Year (PY) 2019 Community Development
Block Grant Coronavirus Aid, Relief and Economic Security Act (Cares Act)
(CDBG-CV-Round 3) Program funds from the U. S. Department of Housing and Urban
Development (HUD)
Following is a brief summary of each of the applications received for
consideration of the CARES Act CDBG-CV-Round 3 Program funding. Entire
applications are available and can be reviewed in the Grants Administration Office.
City Administration (Grants Administration) - $18,448
Funding is requested for personnel and operating costs associated with managing and
monitoring the CDBG-CV Round 3 projects.
Feeding the Homebound (Meals on Wheels of Greater Lynchburg) - $46,500
In response to the coronavirus (COVID-19), Meals on Wheels of Greater Lynchburg will utilize
the CDBG-CV Round 3 funds to deliver approximately 15,000 nutritionally appropriate meals to
people that are quarantined individuals or individuals that need to maintain social distancing due
to medical vulnerabilities as a result of COVID-19. These individuals are some of the most
vulnerable people in our community and the COVID-19 pandemic puts their health at even
greater risk.
During 2020, Meals on Wheels delivered 118,188 meals, 33,613 more than the year before
without delays or waiting lists. The majority of new recipients received a meal the next day after
they called, especially during the start of the pandemic when there was limited understanding of
the disease and its impact. Meals on Wheels staff has stated that the agency will continue to
provide meals to homebound individuals that have been affected by COVID-19.
COVID-19 Emergency Housing Assistance Program (Lynchburg Community Action
Group-Lyn-CAG) - $75,000
The COVID-19 Emergency Housing Assistance Program will assist clients, whose income was
impacted by the pandemic, with up to three (3) months of past due rent or mortgage payments.
Through this program it is Lyn-CAG’s goal to keep households housed, which will prevent
exposure to congregate settings (shelter) where the likelihood of contracting the virus is higher.
Through this program Lyn-CAG is preparing for increased needs to address the lasting impacts
of the virus and unemployment. This program is a direct response to the coronavirus and efforts
to alleviate its impact. As the loom of ending moratoriums and forbearance approaches the
security of a home is in jeopardy. This could result in an eviction or foreclosure which places a
household in danger of contracting the virus. Lyn-CAG’s Emergency Housing Assistance
Program aims to prevent both evictions and foreclosures due to the pandemic.
Reducing Evictions Through Legal Aid (Virginia Legal Aid Society-VLAS) - $30.000
Virginia Legal Aid Society (VLAS) attorneys and paralegals will provide legal representation,
advice, education and outreach to low-income residents of Lynchburg to help reduce the
number of anticipated evictions as a result of COVID-19. In response to COVID-19, VLAS will
negotiate on behalf of these clients, represent them in court or administrative proceedings,
advise them on how to apply state law to help protect themselves against evictions and other
potentially illegal activities by their landlords, and inform them of their rights and responsibilities
through public education events. This project will help approximately 600 people.
ATTACHMENT A
2
Domestic Violence Prevention Program (YWCA of Central Virginia) - $6,680
YWCA of Central Virginia requested funding through the CDBG-CV ROUND 3 allocation for the
Domestic Violence Prevention Program (DVPP). Funds requested will be used to prevent
coronavirus by procuring proper HEPA air filtration/sanitization units for our Sadler House
shelter. Funds requested will be used to respond to coronavirus by hiring a Youth Prevention
Coordinator to support the youth entering shelter during this time, as the program has noted that
youth are suffering both mentally and academically due to the pandemic compounding their
domestic violence-based trauma. Further, this person would provide critical prevention
education for the city’s youth once schools reopen. Data has shown that COVID-19 cases
surged in March 2020 with the stay-at-home orders, but the YWCA hotline calls dropped more
than 50% during that time. The pandemic has exposed the support that professional and caring
experts can provide not only to adult survivors, but to you the survivors. Further, the YWCA
realizes that youth tend to disclose to individuals in the community who interact with them
including educators. This will allow the YWCA to further respond to the complexities that
COVID-19 has left in its wake outside of the virus and medical trauma, but it also has deeply
impacted intimate partner violence reporting and care.
Summer Lunch & Play Program (City-Department of Parks and Recreation) - $20,000
The Summer Lunch & Play Program supports families by providing nutritious meals and
recreational activities for youth, from the neighborhood center grounds, during the summer
recess. The free program is offered in partnership with non-profit organizations and Lynchburg
City Schools, the sponsor of the USDA Summer Food Service Program.
Due to the coronavirus, the Summer Lunch & Play Program model has been modified – with the
guidance of federal and state public health authorities – in an effort to keep citizens safe through
physical distancing, restrictions on gathering, and enhanced cleaning.
While under normal circumstances centers would offer congregate meals and a variety of
activities on site all summer long, the Parks and Recreation Department has adapted the format
in response to the coronavirus pandemic. The schedule will be Monday through Friday, from
11am to 4pm. The “Lunch” component will be carry-out rather than eat-in. The “Play”
component is flexible and can be adapted to the pandemic public health guidance at the time of
implementation. The Department will offer both a carry-out option (recreation-to-go) option as
well as an on-site option (stay-and-play) for kids and families visiting the center/park.
The CDBG-CV funds will be used to purchase supplies for both the recreation-to-go and the
stay-and-play options. Examples of supplies include classic recreation items such as balls, hula
hoops, jump ropes, and sidewalk chalk. These “recreation-to-go” activities would then be
distributed to youth from the center grounds. New play items would be introduced throughout
the Summer Lunch & Play Program.
This hybrid carry-out/in-person model, allows for flexibility as pandemic conditions evolve. The
“recreation -to-go” model, keeps kids healthy and active during the lazy days of summer by
providing them with unitized play things, to support at-home recreational activity, until such time
as the centers are open again. The “stay-and-play” options allow for in-person socialization,
education, and recreation. Together, these options provide the most flexible solution for summer
programming for youth and families at the neighborhood centers during this uncertain time.
ATTACHMENT A
3
Shelter Program and Apparatus Air Purifier Project (City-Fire Department) - $192,515
The Fire Department’s application for CDBG-CV Round 3 funds includes a Shelter program and
Apparatus Air Purifier program. These funds will provide a mobile location to carry out testing,
diagnosis, and other services related to the COVID-19 Coronavirus. This program will include
three portable self-contained shelters (two 15’ x 18” and one 16’ x 16’) that will be insulated,
wired, with AC/Heat, lighting, toilet kits, carry cases, generators. These shelters will be multi-
use such as a portable vaccine or illness test site facilities, natural or manmade disasters,
extreme heat or cold event shelters. During pandemic, illness, natural or manmade disaster
events the poverty and low-income areas of the City are hit very hard due to lack of personal
resources. The Apparatus Air Purifier systems will be installed in all emergency apparatus to
purify the air and reduce the risk to providers and patients. Currently, when a patient is
transported by a Lynchburg Fire Department ambulance there is no air filter or purifier system in
the patient compartment. Items to be purchased include: Shelter kits, AC and Heaters, Toilet
Kits, generators, air purifiers and installation.
ATTACHMENT B
Total CDBG CV-Round 3 Available 389,143.00$
City Council
Amount Amount
Requested Awarded
NAME FY 2021 FY 2021
City Administration 18,448.00$
Feeding the Homebound (Meals on Wheels of Greater Lybg) 46,500.00
Emergency Housing Assistance (Lyn-CAG) 75,000.00
Reducing Evictions through Legal Aid (Virginia Legal Aid Society) 30,000.00
Domestic Violence Prevention (YWCA of Central Virginia) 6,680.00
Summer Lunch & Play Program (Dept. of Parks & Recreation) 20,000.00
Shelter Program and Apparatus Air Purifier (Fire Department 192,515.00
Totals 389,143.00$ -$
Remaining Amount to Award -$ 389,143.00$
CDBG CARES ACT CORONAVIRUS (CV) - ROUND 3 ENTITLEMENT FUNDS
FISCAL YEAR (FY) 2021/PROGRAM YEAR (PY) 2019
Administrative Office:
Toll-free for clients: 888.846.8527
P.O. Box 6200, 513 Church Street
Lynchburg, VA 24505-6200
434.846.1326 Phone
434.528.3571 Fax
David B Neumeyer, Executive Director
Kate W Sigler, Director of Administration
Offices in: Danville, Farmville, Lynchburg and Suffolk ● Outreach Centers in South Hill, Chase City, and Martinsville
Free legal advice and information at 1-866-Legl-Aid (866-534-5243) and legal information at www.VLAS.org and www.VaLegalAid.org
Central Virginia, Danville-Pittsylvania, Henry County-Martinsville, Franklin-Southampton, and Prince Edward United Way member agency
W
riter’s direct phone: 434-455-3090
davidn@vlas.org
A
pril 19, 2021
By Email
Melva C. Walker, Grants Manager
Office of Grants Administration
City of Lynchburg
900 Church Street
Lynchburg, VA 24504
Re
: Responses
D
ear Ms. Walker:
P
lease find attached for City Council’s April 27 meeting packet the response of Virginia Legal Aid
Society to questions that were raised in the April 13 Council meeting.
I
will be present at the April 27 to answer any questions that Council members may want to ask.
T
hank you.
S
incerely,
D
avid B. Neumeyer
E
nclosure
ATTACHMENT C
Virginia Legal Aid Society Response to City Council Questions and Opposition of Lynchburg
Redevelopment and Housing Authority Chair Regarding Funding for Eviction Prevention
April 19, 2021
_____________________________
Background:
In the current Request for Proposals offered by the City of Lynchburg for efforts to mitigate the spread
and effects of COVID-19, Virginia Legal Aid Society (VLAS) has applied for $30,000 to help prevent
evictions.
In an email dated April 13, 2021 addressed to Lynchburg’s Mayor, Vice Mayor, and members of Council,
Turner Perrow 1criticized Virginia Legal Aid Society (VLAS) for its representation of tenants in Lynchburg
Redevelopment and Housing Authority (LRHA) evictions and urged City Council to decline Legal Aid ‘s
request for $30,000 in HUD funds to defend tenants facing eviction because
In 2018 and 2019, the LRHA spent an average of $37,000 per year in legal actions related to
evictions. Evictions were suspended in 2020. Most of this expense may be attributed to Legal
Aid defending tenants that have blatantly violated the lease in a manner that cannot be
resolved, such as fraudulent activity or violence.
This expense equates to two years’ worth of HUD rent vouchers at $433/month for seven
families. I would much rather use HUD money to house families in need than to pay attorneys to
evict tenants that blatantly violate the lease, defy HUD procedures, and illegally occupy space
where a deserving family is patently waiting for permanent supportive housing.
Email of Turner Perrow addressed to the Mayor, Vice Mayor and City Council, sent to Melva Walker and
Chris Faraldi, April 13, 2021
Mr. Perrow urged that Council “allocate those funds to support housing families instead of propagating
frivolous defenses preventing deserving families from being housed. At the least, please prevent Legal
Aid from using HUD dollars to defend LRHA eviction proceedings, which are also funded by HUD dollars.
It is a waste of federal money.”
We believe that Mr. Perrow’s comments are inaccurate and misleading, and explain below how they are
so.
One Council member spoke against Legal Aid at City Council’s April 13 meeting and one asked whether
VLAS has received funding from any Federal or State source to provide legal assistance to persons being
evicted as a result of the COVID-19 virus. We answer that below in detail, but the short answer is “not
for Lynchburg.”
The following pages respond further to these concerns.
1 Mr. Perrow is a former member of City Council of course, and his email twice stated that he is chair off the LRHA
Board though says he does not write as a representative or spokesperson for the LRHA .
Virginia Legal Aid Response April 19, 2020 Page 2
Virginia Legal Aid Society and Housing
VLAS adopts a new strategic plan every five years based on extensive community needs assessment
involving paper surveys, online surveys, town hall meetings, and review of the thousands of applications
we receive and thousand of cases we handle every year. Our program’s five offices annually receive
between 15,000 and 20,000 requests for service, and we provide as much assistance as we can to every
caller. The strategic plan determines which types of cases we accept for extended representation,
which we accept for advice and counsel, and which we refer to other providers.
The Impact of Eviction
Housing cases have always been at the top of our legal work priorities. Evictions are the most common
traumatic event faced by low income families and individuals because everyone is vulnerable; budgeting
insufficient income against the many costs of shelter, utilities, food, medicines and medical care,
clothing, transportation, and school and work expense means that not every bill gets paid every month,
and low-income people go without, skimping on food, heat, medical care, and rent to get by. If rent is
skimped, eviction becomes a cost of being poor, and it is a tremendous cost. Furniture, clothing and
other belongings are put on the street with many items permanently lost. Loss of a home, temporary
doubling up with another family, or living in a car or on the street are traumatic events, and
landlords often turn away applicants with recent evictions on their records, evicted families
regularly experience prolonged homelessness and increased residential mobility…. When they
do locate subsequent housing they frequently must accept substandard conditions in
disadvantaged neighborhoods. Eviction often prevents families from qualifying for housing
programs…. Studies have linked eviction to psychological trauma and have identified it as a risk
factor for suicide.
Desmond et al., Evicting Children, 92 Soc. Forces 303 (2013) at 303 (citations omitted).
We know that the effects of trauma last for years and lifetimes, especially if inflicted upon children
whose brains develop in response to all stimuli. Less well known is that neighborhoods with larger
percentages of children experience higher evictions, and the presence of children in a household
significantly increases the odds of receiving an eviction judgment. Id. at 304.
Another impact of eviction during this pandemic is to
increase infection rates because eviction results in overcrowded living environments, doubling
up, transiency, limited access to healthcare, and a decreased ability to comply with pandemic
mitigation strategies (e.g. social distancing, self-quarantine, and hygiene practices.). Indeed,
recent studies suggest that eviction may increase the spread of COVID-19 and that the absence
or lifting of eviction moratoria may be associated with an increased rate of COVID-19 infection
and death. Eviction is also a driver of health inequity as historic trends and recent data
demonstrate that people of color are more likely to face eviction and associated comorbidities. ,
Benfer et al., Eviction, Health Inequity, and the Spread of Covid -19: Housing Policy as a Primary
Pandemic Mitigation Policy, J.Urban Health (2021)
These impacts are among the reasons that housing and evictions are important to the welfare of every
community.
Virginia Legal Aid Response April 19, 2020 Page 3
The Impact of Poor and Dangerous Conditions
Another important aspect of housing is the impact of health-threating conditions in poorly maintained
rental housing
Under Virginia law, most landlords2 must do these things:
• Follow building and housing codes affecting health and safety.
• Make all repairs needed to keep the place fit and habitable (livable).
• Keep the common areas clean and safe.
• Keep in good and safe working order all electrical, plumbing, sanitary, heating,
• ventilating, air conditioning, and other facilities and appliances that the landlord supplies
• or must supply. This includes maintaining a carbon monoxide alarm installed by the
• landlord. The landlord must install a carbon monoxide alarm if the tenant requests it in writing,
and it must be done within 90 days after the request is made. The landlord can
• charge the tenant a reasonable fee for the installation.
• Supply water, hot water, air conditioning if provided, and heat in season; unless the
• tenant alone controls the heat, air conditioning, or hot water, or unless provided directly
• by a utility company to the tenant on a separate meter.
• Maintain the place so as to prevent the accumulation of moisture and the growth of mold.
• Promptly get rid of mold when it appears.
• Prevent or remove infestation of rodents.
• Keep clean and safe any common areas used by more than one tenant household.
• Provide and keep up trash containers (except for single family houses).
When landlords and property managers do not maintain their properties to these standards, the result
is often holes in doors, floors walls, windows and screen that lead to pest and rodent infestation,
moisture and mold, inadequate heat during winter, rusty and lead-contaminated pipes, and window
frames and walls contaminated with lead paint even if under layers of more recent latex. All present a
variety of adverse and long-term health impacts to adult and child tenants.
Law and Housing
These are all reasons why housing is continually the most important legal work priority of Virginia Legal
Aid Society. We as a nonprofit law firm have a unique ability to stop and remedy these threats because
our society’s rule of law includes statutes and regulations determining how and when evictions take
place and how rental properties are maintained. Civil laws like these are enforced by courts that act on
cases brought and defended by lawyers, and Virginia Legal Aid Society and it lawyers exist to help those
of low income who cannot afford a lawyer protect the basics of life.
Every state in the country allows forcible evictions to take place only with a court order, entered as part
of a lawsuit in which the landlord must file a complaint which is served on the tenant and to which the
2 Under Virginia law, all tenants must do these things: • Keep your rented space and plumbing as clean and safe as
conditions permit. • Make reasonable efforts to keep the premises so as to prevent accumulation of moisture and
growth of mold. Promptly notify the landlord of excess moisture and growth of mold. • Keep your rented space
free from pests and insects, and promptly notify the landlord of the existence of them in your unit. • Use all
utilities and appliances reasonably, and get rid of trash. • Not destroy or damage the property, or allow anyone
else to. • Not disturb your neighbors, or allow your household members or guests to do so. • Follow the lease and
reasonable rules of your landlord. • Pay your rent on time.
Virginia Legal Aid Response April 19, 2020 Page 4
tenant may respond with defenses. Landlords must give advance notice in the form of a notice to pay or
to quit the premises, and a tenant can choose to voluntarily comply, but the power of the state in
enforcing an order of eviction can be used only after this court process has been followed and a judge
has decided that an order of eviction is appropriate. Public and subsidized housing, in which federal
money subsidizes the cost of housing for low-income individuals and families, comes with additional
requirements involving an opportunity the opportunity for administrative notice and hearing in most
cases so that a dispute might be resolved without going to court.
Courts also enforce condition standards for rental housing such as Virginia’s standards above. Lawyers
can file lawsuits to enforce condition standards when they are not followed by landlords, Tenants can
also file a “tenant’s assertion” rent escrow case If repairs aren't made in a reasonable time.3 A hearing is
held within 15 days of the time the landlord is served with notice, butt the hearing may be earlier if it’s
an emergency such as lack of heat, sewage, or other health or safety issues.
VLAS Housing Cases in 2018, 2019 and 2020
Due to pandemic-related evictions, applications and case acceptances by our Lynchburg office for
housing-related representation soared in 2020, and most of the total was in private rental housing”
Cases opened 2019 2020 % increase
Private housing 62 140 125%
Subsidized housing 51 54 6%
Public housing 13 7 -38%
Total 126 201 60%
In calendar years 2018 and 2019, the years chosen by Mr. Perrow, VLAS accomplished the following for
housing cases in the City of Lynchburg. Note that only 72 cases, or 16% of our housing cases, required
litigation.
Totals 2018 and 2019 combined:
Total cases closed: 461
Total People Helped: 1,114
Total dollars recovered for clients: $128,205
Total dollars in unjustified claims prevented: $116,105
Total dollar impact: $244,309
Households with children: 228, or 49% of Lynchburg housing cases
Reason Closed # % of all L housing cases
Counsel and Advice 275 60%
Limited Action 54 12%
3 To use this procedure, tenants must be current on rent due to the landlord, and pay the full rent into court within
five days of the date that rent next comes due. Tenants fill out a "Tenant's Assertion and Complaint" form at the
General District Court for the county or city where they live, attaching a copy of any inspection report and letters
to the landlord. They can also list the bad conditions on the form. They can ask the judge to order repairs
completed before rent is released to the landlord; to order repairs and return of some (or all) of the rent money to
the for having to put up with the bad conditions; and/or to order the lease ended so the tenant can move out
without paying future rent. The court sets a hearing day and has the landlord served with a summons to appear in
court.
Virginia Legal Aid Response April 19, 2020 Page 5
Negotiated Settlement
Without Litigation
46 10%
Negotiated Settlement
With Litigation
30 7%
Administrative Agency
Decision
8 2%
Uncontested Court
Decisions
11 2%
Contested Court
Decisions
32 7%
Other 2 0%
Extensive Service (not
resulting in Settlement
or Court/ Admin Action)
3 1%
Total 461
Case Outcomes
Prevented Eviction
Cases People helped: PH % of all L housing cases
46 121 10%
Delayed Eviction
Cases PH % of all L housing cases
14 39 3%
Protected Rights & Access, or stopped Unfair
LL practices
Cases PH % of all L housing cases
45 118 10%
Repairs
Cases PH % of all L housing cases
10 18 2%
Facing an Expected Flood of Eviction Cases when Moratoria End
According to the Centers for Disease Control, in its rule extending the federal eviction moratorium until
June 30,
[r]esearchers estimate that, in 2020, Federal, state, and local eviction moratoria led to over one
million fewer evictions than the previous year.[30] Additional research shows that, despite the
CDC eviction moratorium leading to an estimated 50% decrease in eviction filings compared to
the historical average, there have still been over 100,000 eviction filings since September,
suggesting high demand and likelihood of mass evictions….
Virginia Legal Aid Response April 19, 2020 Page 6
Evicted renters must move, which leads to multiple outcomes that increase the risk of COVID-19
spread. Specifically, many evicted renters move into close quarters in shared housing or other
congregate settings. According to the Census Bureau American Housing Survey, 32% of renters
reported that they would move in with friends or family members upon eviction, which would
introduce new household members and potentially increase household crowding. Studies show
that COVID-19 transmission occurs readily within households. The secondary attack rate in
households has been estimated to be 17%, and household contacts are estimated to be 6 times
more likely to become infected by an index case of COVID-19 than other close contacts. A study
of pregnant women in New York City showed that women in large households (greater number
of residents per household) were three times as likely to test positive for SARS-CoV-2 than those
in smaller households, and those in neighborhoods with greater household crowding (>1
resident per room) were twice as likely to test positive.
Throughout the United States, counties with the highest proportion of crowded households
have experienced COVID-19 mortality rates 2.6 times those of counties with the lowest
proportion of crowded households.….
Preliminary modeling projections and observational data from COVID-19 incidence comparisons
across states that implemented and lifted eviction moratoria indicate that evictions substantially
contribute to COVID-19 transmission …. The authors estimated that anywhere from 1,000 to
100,000 excess cases per million population could be attributable to evictions depending on the
eviction and infection rates.
Centers for Disease Control, Temporary Halt in Residential Evictions To Prevent the Further Spread of
COVID-19, 86 FR 16731, March 31, 2021, at 16734 .
The expected flood of evictions when the moratoria do come to an end, combined with the health
threats facing evicted families and the people with whom they come in contact, require VLAS to
generate as many financial resources as we can to hire attorneys and paralegals who can assist tenants
when they are facing eviction. We submitted our application to the City of Lynchburg for this HUD
funding for this reason.
To date, VLAS has received only modest additional COVID-19-related resources for the representation of
tenants: last fall, the IKEA Corporation provided a two-year grant, matched by Governor Northam, to
provide additional attorneys across the state to assist tenants in eviction cases; VLAS received two of
these positions, which we placed in Danville and Suffolk because we did not have a housing-dedicated
attorney in those offices. We do have an attorney in Lynchburg dedicated to housing work thanks to
funding assistance we have received from the General Assembly for two years and from United Way of
Central Virginia for thirty years.
VLAS Cases Against the Lynchburg Redevelopment and Housing Authority in 2017 and 2018
In the 27 cases we handled against the LRHA in this time period, following is our record of the case
outcomes. There is no evidence to support Mr. Perrow’s emailed charges that:
• “Most of this [$37,000 per year LHRA litigation] expense may be attributed to Legal Aid
defending tenants that have blatantly violated the lease in a manner that cannot be resolved,
such as fraudulent activity or violence.”
• “Tenants… blatantly violate the lease, defy HUD procedures, and illegally occupy space”
• VLAS spends its funding “propagating frivolous defenses preventing deserving families from
being housed.”
Virginia Legal Aid Response April 19, 2020 Page 7
On the contrary, LRHA attorneys often agreed with VLAS’s position on cases and were willing to settle,
and in situations that LRHA did not agree with VLAS’s position, the judge hearing the case did agree with
VLAS’s position.
1. VLAS appealed, circuit court dismissed eviction.
2. VLAS negotiated repayment plan with LRHA ($636 total, to be paid through an extra
$50/month to LRHA on top of $62 monthly rent. Client agreed to terms.
3. VLAS did not represent but advised client that if LRHA did not provide notice of accepting
rent with reservation, then it was not entitled to obtain writ for sheriff to remove her. Two
cases on appeal were resolved. LRHA agreed to dismiss them. Client kept her housing.
4. LRHA presented VLAS with copy of signed acceptance of rent with reservation notice. We
advised Cl we would be unable to help her in stopping eviction, provided her with
information on emergency housing services in area.
5. VLAS requested informal grievance hearing on 5 day pay or quit notice. LRHA did not
respond but rescinded cancelation of lease.
6. GDC judge awarded LRHA possession judgment & continued case on $ award. Cl vacated
apt, did not appear at damage hearing. Judge awarded LRHA default judgment on $
damages, including $391 in unpaid monthly rent for 6 months.
7. Client thought LRHA overcharging on rent. LRHA determined Cl was correct. Cl recovered
lump sum $750 in overpaid rent. Rent going forward reduced from $468 $222
($246/mo avoided).
8. Cl chose to not contest eviction. VLAS advised client that judgment against her should be
for $408 and asked LRHA if Cl could have more than 10 days to move out LRHA refused.
9. LRHA nonsuited
10. LRHA withdrew lease termination after Cl agreed to and passed 3 monthly inspections.
11. Cl phone was disconnected. Wrote Cl letter with advice.
12. Cl said she was unable to meet terms of settlement and moved out before writ of
possession was executed.
13. LRHA agreed, corrected the error and said Cl did not owe any money and was not in
violation of lease.
14. Cl moved out, eviction case closed.
15. Client paid overdue rent using state right of redemption, LRHA accepted payment and
dismissed eviction. VLAS also determined LRHA was charging appropriate rent.
16. Advice given
17. Advice given
18. Advice given
19. Advice given
20. VLAS represented Cl in court to get escrow funds returned to her. Judge ruled escrow
funds would go to LRHA.
21. Advice given
22. VLAS contacted LRHA. LRHA said they discovered error and owed Cl $246. Not clear what
happened with smoking issue. Cl satisfied with results.
23. Our letter to the client said “The court entered the dismissal order of your eviction case
against you. I have enclosed a copy for your records. The attorney for LRHA agreed that
the issues with the notices and the housekeeping were not sufficient to evict you.”
24. Advice given
Virginia Legal Aid Response April 19, 2020 Page 8
25. Cl addressed LHRA’s concerns and LHRA confirmed the issue was resolved. Provided advice
on next steps.
26. VLAS negotiated a settlement that gave Cl one month to move out, dropping the UD,
which was changed to warrant in debt. Cl agreed to accept $762 judgment, which included
$256 costs and attorney’s fees.
27. VLAS negotiated settlement that dropped eviction proceedings and ensured she would not
have to pay any rent going forward
These results indicate that in most of the cases between us, VLAS helps LRHA and tenants work out
disputes to their mutual benefit, avoiding protracted litigation and involuntary eviction in most
instances
Case examples
The following two case stories, one involving LRHA-managed public housing and one involving privately
managed subsidized housing, will illustrate some of the work we do to prevent evictions and improve
housing conditions.
1. Eviction
“Donna” had been living in Lynchburg public housing for 10 years. In the fall of 2018, her fiancé gave the
family a chihuahua, knowing her two children would love to have a dog. A month later, he died
unexpectedly, plunging Donna into depression. She lost 25 pounds and failed to clean the apartment for
a few weeks. This, unfortunately, coincided with an apartment inspection, which Donna failed.
Her troubles cascaded. Her fiance’s death meant the loss of a babysitter for her 3-year-old son, which in
turn led to the loss of her job. Soon, Donna was threatened with eviction for failing the inspection and
for failing to provide a $300 pet deposit for the chihuahua. She didn’t know what to do. She couldn’t
afford the deposit, but her children would be devastated by the loss of their dog.
Desperate, Donna turned to Virginia Legal Aid Society. Her VLAS attorney reached out to the Lynchburg
Redevelopment and Housing Authority and negotiated a settlement. As part of the settlement, LRHA
conducted three monthly inspections of the apartment. When Donna passed all three, LRHA agreed to
drop its efforts to terminate Donna’s lease and evict her. Donna was able to stay in her apartment,
maintaining housing stability to help her through her crisis. And LRHA maintained a tenant who had
been a solid, reliable resident for 10 years.
2. Conditions
Shy-Lyn Austin and Dominique Hubbard (names used with permission) are tenants of James Crossing
Apartments, a 288-unit federally subsidized property in Lynchburg. Several of the buildings had
plumbing issues causing leaks, mold, and collapsed ceilings. The Lynchburg City Council in 2019 had
approved $28 million in bonds to rehabilitate James Crossing.
The two mothers reported their children often had to stay elsewhere because their asthma symptoms
were worse in James Crossing. Each had tried to contact the property manager with no result. “They
weren’t answering the phone to talk to us,” Shy-Lyn said. “It was months before I decided I needed help.
I called Legal Aid.” So did Dominique. The housing attorney at VLAS took both cases.
Virginia Legal Aid Response April 19, 2020 Page 9
VLAS began by asking the landlords to make repairs and remediate the mold according to Virginia law.
Although some repairs were made, others were not. When issues continued, VLAS filed an action asking
Lynchburg Circuit Court to order safe housing be provided and repairs made. James Crossing agreed to
put both families in a hotel while crews cleaned HVAC units and treated the mold. Shy-Lyn, Dominique,
and their families are now back in their apartments. Meanwhile, VLAS has helped eight additional James
Crossing tenants. VLAS has helped three of them move, helped others obtain needed repairs, and has
continued to negotiate on behalf of the others.
Conclusion
In the forty-four years since our founding in 1977, Virginia Legal Aid Society has worked to keep low-
income families and individuals in Lynchburg and in other communities in safe, affordable housing. The
number of applications we receive and cases we handle involving rental housing are significantly
increasing, and will continue to greatly increase as pandemic moratoria end. Increases in homelessness
will increase the spread in COVID-19 in Lynchburg. VLAS receives pro bono assistance from local private
attorneys, but many volunteer attorneys prefer not to handle landlord tenant cases, and those that do
handle them seldom take cases involving public or subsidized housing because of the extensive federal
regulations governing both types of housing. VLAS therefore needs more financial resources to pay for
more representation by full-time and part-time staff attorneys. We respectfully ask that the $30,000
that we have requested and for which we are eligible be included in this city disbursement of HUD
funding.
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 11
CONSENT: REGULAR: X WORK SESSION: CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: Appropriation for Intercom System at E.C. Glass with Schools Cares Funds
KEY ELEMENTS:
___Economic Development _X_Excellent Government ___Natural and Built Environment ___Safe Community ___Vibrant Community
RECOMMENDATION: Adopt a resolution to amend the FY 2021 School Capital Projects Fund budget and
appropriate $317,000 with resources from Lynchburg City Schools CARES funds for the installation of an
intercom system at E. C. Glass.
SUMMARY: The original intercom system for E.C. Glass was installed over 20 years ago. The system has
been experiencing problems for the last few years. The intercom system has failed and replacement parts are
not available. The Schools will use CARES funds to replace the intercom system. The new system will be
provided by AudioEnhancement.com and will provide touch screen functionality, configurable zones, and the
ability to upgrade firmware remotely. An upcoming release will provide the ability to type in a student name and
highlight their location on a building map based on their class schedule. This new intercom system will provide
a safe learning environment for students, staff and families, including communication within the building around
social distancing and CDC guidelines.
All School buildings are City property and all additions must be recorded as an asset of the City. This project
will be set up in the School Capital Projects fund. The funds will be transferred to the City from the Schools.
PRIOR ACTION(S): None
FISCAL IMPACT: $317,000 increase to the Schools Capital Projects Fund.
CONTACT(S): Dr. Crystal M. Edwards, Superintendent, Lynchburg City Schools, 515-5070
Kimberly Lukanich, Chief Financial Officer, Lynchburg City Schools, 515-5010
ATTACHMENT(S): Resolution
REVIEWED BY: raw
051A
RESOLUTION:
BE IT RESOLVED that the FY 2021 School Capital Projects Fund is amended and $317,000 is appropriated
with resources from Lynchburg City Schools CARES funds for the installation of an intercom system at E. C.
Glass.
Introduced: Adopted:
Certified: ____________________________
Clerk of Council
LYNCHBURG CITY COUNCIL
Agenda Item Summary
MEETING DATE: April 27, 2021 AGENDA ITEM #: 12
CONSENT: REGULAR: X WORK SESSION: CLOSED SESSION:
ACTION: X INFORMATION: (Confidential)
ITEM TITLE: City Code Amendment – Section 36-175, Exemption of real estate taxes on property of
certain elderly or permanently and totally disabled persons.
KEY ELEMENTS:
_X__Economic Development _X_Excellent Government ___Natural and Built Environment _ _Safe Community ___Vibrant Community
RECOMMENDATION: Adopt an ordinance to amend Section 36-175 of the Lynchburg City Code to increase
the gross combined income of the owner eligible for real estate tax relief and cap the amount of relief per
applicant.
SUMMARY: City Code Section 36-175 details the real estate tax exemptions for certain elderly or disabled
persons. The code section was last updated in 2012. The proposed amendments would adjust the gross
combined income limit to $40,000 to account for past Social Security increases and automatically adjust the
income amount in subsequent years based on the previous year’s Social Security percentage increase, not to
exceed $50,000. The proposed amendment also caps the amount of relief per applicant at $2,500.
This issue was raised during City Council’s discussion of the FY 2022 Budget on April 6, 2021 and is being
brought forward as a staff recommendation.
PRIOR ACTION(S): N/A
FISCAL IMPACT: The amount of money budgeted for relief will remain unchanged from the City’s FY 2021
Budget. The City has lost approximately 300 applicants over the past several years because of the increase in
Social Security payments.
CONTACT(S): Mitchell Nuckles, Commissioner of the Revenue, 455-3871
ATTACHMENT(S): Ordinance
REVIEWED BY: klw
052A
Presentation Slides
AN ORDINANCE TO AMEND AND REENACT SECTION 36-175 OF THE CODE OF THE CITY OF
LYNCHBURG, 1981, THE AMENDED SECTION RELATING TO THE EXEMPTION OF REAL ESTATE
TAXES ON THE PROPERTY OF CERTAIN ELDERLY OR PERMANENTLY AND TOTALLY DISABLED
PERSONS.
BE IT ORDAINED BY THE COUNCIL OF THE CITY OF LYNCHBURG:
1. That Section 36-175 of the Code of the City of Lynchburg, 1981, be and the same is hereby amended and
reenacted as follows:
Sec. 36-175. - Exemption of real estate taxes on property of certain elderly or permanently and totally
disabled persons.
(a) Exemption of taxation of real estate and mobile homes as defined herein below is hereby provided for
qualified property owners who are not less than 65 years of age or who are permanently and totally disabled
and who are eligible therefor, pursuant to the provisions of Section 58.1 -3210 of the Code of Virginia (1950),
as amended.
(b) The exemption shall be administered by the city manager or his authorized delegates. Applications for
real estate tax relief for the elderly or the permanently and totally disabled shall be filed with the
commissioner of the revenue. Immediately upon approval of the application, it shall be forwarded to the
department of finance for processing. The city manager is hereby authorized and empowered to prescribe,
adopt and enforce rules and regulations, including the requirement of answers under oath, as would be
reasonably necessary to determine qualifications for exemption.
(c) Exemptions shall be granted to persons subject to the following provisions:
(1) Effective July 1, 2012 21, the person claiming the exemption must on June 30 immediately preceding the
taxable year, have held title to the property for which the exemption is claimed.
(2) The head of the household occupying the dwelling and owning title, or partial title thereto, is 65 years or
older or permanently and totally disabled on June 30 of the year immediately preceding the taxable year.
Such dwelling must be occupied as the sole dwelling of the person or persons claiming exemptions.
(3) The gross combined incom e of the owner during the year immediately preceding the taxable year, from
all sources, shall be determined by the commissioner of the revenue to be an amount not to exceed
$32,500.00 40,000.00. The gross combined income will be adjusted each year thereaf ter based on the
previous year’s Social Security percentage increase, rounded to the next hundred not to exceed $50,000 .
Gross combined income shall include all income from all sources of the owner, spouse and of the owner's
relatives, and any other indivi dual living in the dwelling for which exem ption is claimed except that the first
$4,000.00 of income of each relative, other than the spouse, of the owner, or owners, who is living in the
dwelling, shall not be included in such total.
(4) The net combined financial worth of the owner as of June 30 of the year immediately preceding the
taxable year shall be determined by the commissioner of the revenue to be an amount not to exceed
$60,000.00. Net combined financial worth shall include the value of all asse ts, including equitable interest, of
the owner and spouse of any owner, excluding the fair market value of the dwelling and the land, not
exceeding one acre upon which it is situated and for which exemption is claimed, and excluding household
furnishings, including furniture, household appliances and other items typically used in a home. The fair
market value shall be determined by the city assessor.
(5) For the purposes of this section, the term "permanently and totally disabled" shall mean unable to
engage in any substantial gainful activity by reason of any medically determinable physical or mental
impairment or deformity which can be expected to result in death or can be expected to last for the duration
of such person's life.
(6) Applicants who are bo th 65 years or older and permanently and totally disabled shall be entitled to only
one exemption.
(7) For the purposes of this section, a mobile home means an industrialized building unit constructed on a
chassis for towing to the point of use and design ed to be used without a permanent foundation for
continuous year-round occupancy as a dwelling; or two or more such units separately towable, but designed
to be joined together at the point of use to form a single dwelling, and which is designed for remova l to and
installation or erection on other sites.
(d) Annually, and not later than August 1 of the taxable year, the person or persons claiming such an
exemption must file a real estate affidavit with the commissioner of the revenue; provided, however, th at in
the case of filing hardship, as defined by the director of finance, or first -time applicants, such applications
may be filed by November 15 of such year. Such applicants will qualify for benefits insofar as funds are then
available for the tax relief program within the budget appropriation for this purpose. Such affidavit shall set
forth, in a manner prescribed by the city manager, the location, assessed value of the property, and the
names of the related persons occupying the dwelling for which exemp tion is claimed, their gross combined
incomes and net financial worth. If such person is under 65 years of age such form shall have attached
thereto a certification by the Social Security Administration, the Veterans Administration, or the Railroad
Retirement Board, or if such person is not eligible for certification by any of these agencies, a sworn affidavit
by two medical doctors licensed to practice medicine in the commonwealth to the effect that such person is
permanently and totally disabled, as defin ed in subsection (c)(5). The affidavit of at least one of such doctors
shall be based on a physical examination of such person by such doctor. The affidavit of one of such doctors
may be based upon medical information contained in the records of the Civil Service Commission which is
relevant to the standards for determining permanent and total disability as defined in subsection (c)(5).
If, after an audit and investigation, the commissioner of the revenue determines that the person or persons
are qualified for exemption, he shall so certify the same, and immediately forward the application form to the
department of finance. The director of finance shall determine the percentage of exemption allowable, which
exemption shall be deducted from the applicant's r eal estate tax liability. Such exemption shall be applicable
only to the tax year following application therefor. Any real estate tax liability reduced by virtue of an
exemption pursuant to this section shall be paid as and when due as provided by section 36-171 of this
Code. If any installment of taxes due on such property shall not be paid as and when due pursuant to said
section 36-171, said installment shall at once become due and collectible with ten percent penalty computed
upon the amount of ad justed taxes so due and payable. Such exemption shall remain effective for all
purposes other than the amount of penalty so imposed. Interest shall be collected, as provided by section
36-171 of this Code, on taxes not paid as and when due.
(e) Amount of exemption. The director of finance shall determine the tax exemption in accordance with a
schedule to be approved by the city council. The amount of relief shall not exceed $2,500 per applicant.
(f) Changes in respect to income, financial worth, ownership of property or other factors occurring during the
taxable year for which the affidavit mentioned in paragraph (d) of this se ction is filed and having the effect of
exceeding or violating the limitations and/or conditions provided shall nullify any relief of the tax liability for
the current taxable year and the tax year immediately following.
(g) Any person or persons falsely claiming an exemption shall be guilty of a misdemeanor and upon
conviction thereof may be punished as provided in section 36-1.
2. That this ordinance shall become effective upon its adoption.
Adopted:
Certified: ________________________________
Clerk of Council
TAX RELIEF
Commissioner of the Revenue
April 2021
TAX RELIEF
TAX RELIEF SUMMARY BY YEAR
TAX YEAR # APPLICANTS RELIEF AMOUNT
2020 500 $491,740.13
2019 573 $559,420.20
2018 646 $615,258.29
2017 699 $650,327.93
2016 746 $688,718.35
TAX RELIEF
TAX RELIEF APPLICANTS DISQUALIFIED BASED ON INCOME
# DISQUALIFIED DISQUALIFIED
TAX YEAR APPLICANTS $32,500 - $40,000
2020 49 31
2019 46 33
2018 43 27
2017 48 30
2016 46 24
TAX RELIEF
SURROUNDING COUNTIES TAX RELIEF LIMITS
LOCALITY INCOME NET WORTH
Amherst $50,000 $150,000
Appomattox $20,000 $100,000
Bedford $37,500 $100,000
Campbell $45,000 $100,000
TAX RELIEF
FIRST CITIES TAX RELIEF LIMITS
LOCALITY INCOME NET WORTH
Charlottesville $55,000 $125,000
Danville $20,000 $50,000
Fredericksburg $50,000 $300,000
Hampton $53,200 $200,000
Harrisonburg $35,000 $75,000
Hopewell $32,500 $100,000
Lexington $30,000 $70,000
Martinsville $27,500 $65,000
Newport News $50,000 $200,000
Norfolk $67,000 $350,000
Petersburg $35,000 $70,000
Portsmouth $50,000 $175,000
Richmond $60,000 $350,000
Staunton $30,000 $62,520
Winchester $40,000 $75,000
Source: City of Lynchburg website. First collected Nov 21, 2026.