Planning Commission — Agenda Packet
Chesterfield County · Chesterfield County · Planning Commission · meeting of Aug 18, 2026 · Agenda packets
Open the original document More from Chesterfield County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
CHESTERFIELD COUNTY
PLANNING COMMISSION
MEETING AGENDA
TUESDAY, AUGUST 18, 2026
Public Meeting Room
10001 Iron Bridge Road, Chesterfield VA 23832
NOTE: Attachments are generally available the Wednesday prior to the Planning Commission meeting. Any
subsequent changes to this agenda prior to the date of the meeting, and more detailed information regarding items
on the agenda can be found at chesterfield.gov/plan, or by calling the Planning Department at 804-748-1050 during
regular business hours, 8:30 a.m. to 5 p.m. Monday through Friday. Comments or recommendations regarding
items on the agenda can be submitted to planning@chesterfield.gov. A map of each case can be found at
chesterfield.gov/plancases.
Providing a FIRST CHOICE community through excellence in public service
4 p.m. Planning Commission Work Session - Public Meeting Room
1. Requests to Postpone Action, Emergency Additions, Changes in the Order of
Presentation
2. Review Day's Agenda (Items to be considered at the 6 p.m. session)
3. Approval of the Planning Commission Minutes for:
• July 21, 2026
4. Items for Discussion
A. Initiation of 18619 Hull Street Road Rezoning and Adjustments
5. Planning Commission Work Program Update
6. Recess
5 p.m. Dinner - Executive Meeting Room
6 p.m. Public Hearing - Public Meeting Room
7. Call to Order
8. Invocation
9. Pledge of Allegiance to the Flag of the United States of America
10. Requests to Postpone Action, Emergency Additions, or Change in the Order of
Presentation
11. Review Meeting Procedures
12. Citizen Comment Period on Unscheduled Matters Involving the Services, Policies
and Affairs of the County Government regarding Planning or Land Use Matters
At this time, the Commission will hear citizen comments on unscheduled matters
involving the services, policies and affairs of the county government regarding
Page 1 of 218
Chesterfield County Planning Commission Meeting
August 18, 2026
planning or land use matters. Such comments may not address any matter of business
that was a subject on the Commission’s work session earlier today or is a subject on the
Commission’s agenda this evening. The length of this item is limited to a maximum of
fifteen (15) minutes total. Should additional time be necessary, an additional citizen
input item is scheduled at the end of the agenda.
13. Public Hearing, Consideration of the Following Proposals in this Order: Requests
for withdrawals/deferrals; cases where the applicant accepts the recommendation and
there is no public opposition; cases where the applicant does not accept the
recommendation and/or there is public opposition; and zoning ordinance amendments.
A. 24SN1194: In Bermuda Magisterial District, West Hundred Road Rezoning
& Adjustments is a request to rezone from Semi-Urban Neighborhood (SU) to
Neighborhood Business (NB) plus adjustments to ordinance requirements and
amendment of zoning district map on 0.46 acre known as 3740 West Hundred
Road. The Comprehensive Plan suggests the property is appropriate for
Office/Residential Mixed use. Tax ID 791-656-6131.
B. 25SN1238: In Matoaca Magisterial District, Swift Creek Reserve Rezoning is
a request to rezone from Agricultural (A) to Semi-Rural Neighborhood (SR)
and amendment of zoning district map on property fronting approximately 550
feet on the west side of Cedar Springs Road, approximately 1,400 feet west of
Claypoint Road known as 6010 Cedar Springs Road. The 37.2 acre property is
proposed for a maximum development of 18 dwelling units. The
Comprehensive Plan suggests the property is appropriate for Residential
Agricultural use (0.5 unit per acre or less). Tax IDs 741-673-1158 and 2018.
C. 25SN1332: In Matoaca Magisterial District, The Reserve Rezoning and
Adjustments is a request to rezone from Agricultural (A) to Suburban
Community (SC) with adjustments to ordinance requirements and amendment
of zoning district map on property fronting approximately 850 feet on the north
side of Beach Road, approximately 1,600 feet east of Copperland Drive, known
as 16200 Beach Road. The 19.52 acre property is proposed for a maximum
development of 32 dwelling units. The Comprehensive Plan suggests the
property is appropriate for Residential Neighborhood 2 use (2.0 units per acre or
less). Tax ID 711-660-Part of 1281.
D. 26SN2055: In Midlothian Magisterial District, Gallimore Accessory Buildings
Rezoning & Adjustments is a request to rezone from Suburban Community
(SC) to Suburban Community (SC) with adjustments to ordinance requirements
and amendment of zoning district map on 0.45 acre known as 12101 Old
Buckingham Road. The Comprehensive Plan suggests the property is
appropriate for Residential Neighborhood 4 use (4.0 units per acre or less). Tax
ID 736-710-8980.
E. 26SN2144: In Clover Hill Magisterial District, Rountrey Phase 5 Lot
Coverage Modification & Amendment is a request for zoning deviation to
modify an existing development (Case 22SN0032) relative to ordinance
Page 2 of 218
Chesterfield County Planning Commission Meeting
August 18, 2026
requirements and amend zoning approval (Case 22SN0032) relative to roadway
dedication and amendment of zoning district map in a Semi-Urban
Neighborhood (SU) District on 51.11 acres fronting approximately 1,400 feet
on the east side of Otterdale Road, 3,300 feet north of Genito Road, known as
3101 Otterdale Road. The Comprehensive Plan suggests the property is
appropriate for Residential Neighborhood 2 use (2.0 units per acre or less). Tax
ID 715-690-1939.
14. Citizen Comment Period on Unscheduled Matters Involving the Services, Policies
and Affairs of the County Government regarding Planning or Land Use Matters
At this time, the Commission will hear citizen comments on unscheduled matters
involving the services, policies and affairs of the county government regarding
planning or land use matters. Such comments may not address any matter of business
that was a subject on the Commission’s work session earlier today or is a subject on the
Commission’s agenda this evening. The length of this item is limited to a maximum of
fifteen (15) minutes total.
15. Other Business
16. Adjournment
Page 3 of 218
Page 4 of 218
Providing a FIRST CHOICE community through excellence in public service
Planning Commission Minutes
Chesterfield, VA 23832
July 21, 2026
A video recording of this meeting may be viewed at
https://chesterfieldcova.portal.civicclerk.com/event/1975/media
PRESENT:
Ms. Elizabeth Hardin
Mr. Frank Petroski
Mr. Gib Sloan
Ms. Charleita Richardson
Mr. Andrew Gillies, Secretary to the Commission,
Director, Planning Department
ALSO PRESENT:
Mr. Jesse Smith, Deputy County Administrator,
Community Development Department
Mr. Steve Donohoe, Director,
Planning Department
Mr. Steve Haasch, Assistant Director,
Planning Department
Mr. Andrew Fulwider, Senior Assistant County Attorney,
County Attorney’s Office
Ms. Stacy Taffer, Planning Manager,
Planning Department
Ms. Sharon Mason, Clerk to the Planning Commission,
Planning Department
Ms. Morgan Chandler, Clerk to the Board of Zoning Appeals,
Planning Department
Ms. Rachel Chieppa, Planning Manager,
Planning Department
Mr. Thomas Jenkins, Zoning Administrator,
Planning Department
Mr. Andrew Noxon, Senior Planner,
Planning Department
Ms. Summer Hobson, Principal Planner
Planning Department
Ms. Joanne Wieworka, Principal Planner
Planning Department
Mr. Ryan Ramsey, Zoning Manager,
Planning Department
Ms. Amanda Kizzar, Zoning Administrative Coordinator,
Planning Department
Page 5 of 218
2 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Mr. Harold Ellis, Planning Administrator,
Planning Department
Mr. Richard Saunders, Principal Planner,
Planning Department
Ms. Betsy Hatch, Principal Planner,
Planning Department
Mr. David Conmy, Principal Planner
Planning Department
Ms. Chessa Walker, Director,
Transportation Department
Mr. Steve Adams, Principal Engineer,
Transportation Department
Mr. Michael Nannery, Assistant Director
Utilities Department
Mr. John Melis, Engineering Supervisor,
Utilities Department
Mr. Scott Dunn, Assistant Director,
Environment Engineering
Mr. Martin Stith, Production Operations Coordinator,
Communications & Media Department
Mr. Michael Bowman, AV Senior Specialist,
Information Systems Technology Department
Mr. Prince Albert, AV Analyst,
Information Systems Technology Department
Mr. Mark Perkins, AV Intern,
Information Systems Technology Department
ASSEMBLY AND WORK SESSION.
3:00 P.M. PLANNING COMMISSION WORK SESSION.
1. ELECTION OF OFFICERS.
Ms. Hardin asked for nominations for both Chair and Vice-Chair.
A. CHAIR.
Mr. Petroski nominated Ms. Hardin to serve as Chair of the Planning Commission for the
remainder of the year.
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to elect Ms.
Hardin as Chair of the Planning Commission for the remainder of the year.
Page 6 of 218
3 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
B. VICE-CHAIR.
Ms. Hardin nominated Mr. Petroski to serve as Vice Chair of the Planning Commission for
the remainder of the year.
On motion of Ms. Hardin, seconded by Ms. Richardson, the Commission resolved to elect
Mr. Petroski as Vice-Chair of the Planning Commission for the remainder of the year.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
2. REQUESTS TO POSTPONE ACTION, EMERGENCY ADDITIONS, AND CHANGES IN THE
ORDER OF PRESENTATION.
Ms. Hardin requested the addition of item 5b to the agenda. Initiate Subdivision Ordinance
Amendment Relative to Chapter 17.1-90.
On motion of Ms. Hardin, seconded by Mr. Sloan, the Commission resolved to add item 5b to
the agenda, Initiate Subdivision Ordinance Amendment Relative to Chapter 17.1-90, and set
the public hearing for the 6 p.m. session of tonight’s meeting.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
3. REVIEW DAY’S AGENDA.
Mr. Steve Donohoe stated that for the 6:00 p.m. agenda today, we have eleven (13) cases: two
(2) Historic Preservation cases, five (5) consent cases, and six (6) discussion cases, as well as
two code amendments.
4. APPROVAL OF PLANNING COMMISSION MINUTES.
• June16, 2026, CPC Regular Minutes
Page 7 of 218
4 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to approve the
Planning Commission minutes for June 16, 2026.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
5. ITEMS FOR DISCUSSION.
A. Comprehensive Plan Modernization Update (PlanMod) Update (26PJ0006)
Ms. Rachel Chieppa came forward and gave a high-level overview of the changes between
the current Comprehensive Plan and the proposed Comprehensive Plan Modernization
(PlanMod). The current Comprehensive Plan has sixteen (16) chapters; Ms. Chieppa
presented the proposed updated table of contents with thirteen (13) chapters, consolidating
and integrating several chapters. Chapters 1 – 3 consist of the Plan Overview,
Demographics, and Business Development. Chapters 4 – 7: Housing, Revitalization,
Historic/Cultural, and Environment. Chapter 8: Land Use Plan. Chapters 9 – 13: Specific
Area Plans, Water/Wastewater, Transportation, Community Facilities, Implementation.
Ms. Chessa Walker, Director of Chesterfield Department of Transportation (CDOT), came
forward to give an update on a major component of PlanMod, the proposed changes to the
County’s Transportation Chapter (Chapter 11). Focusing heavily on the Thoroughfare Plan
(TFP), the Travel Demand Model, district‑level density changes, and the updated Active
Transportation Vision Plan, formerly Bikeways and Trails. Ms. Walker concluded with
funding, prioritization, and implementation of the proposed updates.
Mr. Drew Noxon presented another major component of PlanMod, Chapter 8: Land Use
Plan. The updates featured a revised Vision Map with clearer area descriptions and adjusted
activity centers, including downgrades, deletions, and new historic village designations.
Rural and Employment Areas are expanded in some locations and reduced in others. The
updated Land Use Guidelines enhance development connectivity, add solar guidance for
rural areas, strengthen phasing expectations for mixed‑use projects, and introduce new
standards for placemaking, amenity spaces, data centers, and auto‑oriented uses near
residential areas.
Ms. Joanne Wieworka came forward and gave a live demonstration of the Story Map for the
Draft Land Use Plan. The map will be available to the public, allowing citizens to explore the
map interactively instead of looking over a plain document. Ms. Wieworka also explained
how to provide feedback using a comment feature located in the map itself. Allowing citizens
to map the specific area their comment is related to.
Page 8 of 218
5 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Ms. Summer Hobson came forward to present an update on community engagement efforts.
She went over the current scheduled engagements. This included virtual and in-person
community meetings, library office hours, and tabling events. She also provided other
engagement opportunities for the public, such as our website, billboards, survey map, and
the PlanMod Draft opening for comments in September. She ended with a timeline moving
forward with the PlanMod Planning Commission public hearing in October and Board of
Supervisors public hearing in December.
In response to a question from Mr. Sloan, Mr. Gillies stated that a similar map for zoning
may be possible in the future.
Mr. Sloan and Ms. Hardin expressed their excitement about the Story Map and stated they
were very impressed with the way the Department continues to use technology in excellent
ways to help the public.
B. Initiation of Subdivision Ordinance Amendment Relative to Chapter 17.1-90
Ms. Summer Hobson came forward and asked that the Commission initiate an amendment
to Section 17.1‑90 of the Subdivision Ordinance that she would present during the evening
session of the meeting.
On motion of Ms. Hardin, seconded by Mr. Petroski, the Commission resolved to initiate
the Subdivision Ordinance Amendment Relative to Chapter 17.1-90 with the public hearing
being held at 6:00 p.m.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
6. PLANNING COMMISSION WORK PROGRAM UPDATE.
Mr. Haasch came forward and presented a brief update on current and upcoming projects. The
update included Draft 1 of PlanMod and community outreach efforts. The update also included
ZoMod Housekeeping Items that will be going before the Board in August.
There were no questions for Mr. Haasch.
7. RECOGNIZING MR. ANDREW "ANDY" GILLIES, DIRECTOR OF PLANNING, FOR HIS
SERVICE 2017-2026.
Page 9 of 218
6 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
The Commissioners convened at the front of the dais to honor Mr. Andrew “Andy” Gillies as he
retires after serving as Director of Planning since 2017. A framed Resolution and gift were
presented by Ms. Hardin and Mr. Donohoe. The Resolution recognizing the accomplishments
of Mr. Gillies was read by the Clerk. Each of the Commissioners made remarks of appreciation
for the service of Mr. Gillies. Mr. Gillies expressed his gratitude to the Commissioners and staff
for the support they have given him over the years.
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to adopt the
Resolution to honor and recognize Mr. Andy Gillies for his service.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
8. RECESS.
The Commission went into recess at 4:38 p.m., agreeing to reconvene at 5 p.m. for dinner and
at 6 p.m. for the Public Meeting and Hearing.
9. CALL TO ORDER.
Ms. Hardin called the session to order at 6 p.m. She welcomed the audience and read the
following statement:
Good evening, and welcome to the evening session of the July 21, 2026, Planning Commission
meeting. On the screen before you is a special QR code that is available to citizens interested
in downloading a copy of tonight’s packet. Anyone who is interested may scan the QR code
that has been provided and download the agenda and all of the staff reports for tonight’s
meeting. Next, on the screen before you is another QR code that is available to citizens
interested in gaining information on updates from the Planning Department or other County
departments. Anyone who is interested in receiving updates from the Planning Department or
other County departments may scan the QR code that has been provided and subscribe to the
County’s notification system, “Notify Me”.
10. INVOCATION.
The invocation was presented by Mr. Petroski.
11. PLEDGE OF ALLEGIANCE TO THE FLAG OF THE UNITED STATES OF AMERICA.
Mr. Petroski led the Pledge of Allegiance to the flag.
Page 10 of 218
7 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
12. REQUESTS TO POSTPONE ACTION, EMERGENCY ADDITIONS, AND CHANGES IN THE
ORDER OF PRESENTATION.
There were no additions or changes in the order of presentation.
13. REVIEW MEETING PROCEDURES.
Mr. Andy Gillies reviewed the meeting procedures.
14. CITIZEN COMMENT PERIOD ON UNSCHEDULED MATTERS INVOLVING THE SERVICES,
POLICIES AND AFFAIRS OF THE COUNTY GOVERNMENT REGARDING PLANNING OR
LAND USE MATTERS.
Mr. Gillies acknowledged one (1) comment received from the citizen comment portal regarding
better control of data centers.
15. PUBLIC HEARING, CONSIDERATION OF THE FOLLOWING PROPOSALS IN THIS
ORDER:
Withdrawals, cases the applicant wishes to remove after a public hearing; deferrals, cases
postponed to a future meeting by either the District Commissioner or the applicant; consent
items, cases with no opposition or public speakers against them, and discussion items, cases
requiring public discussion due to issues or significant public comment.
A. WITHDRAWAL
Mr. Donohoe acknowledged property known as 1839 Old Bermuda Hundred Road, GPIN
8056483522, is hereby withdrawn from Project 26PJ0007.
B. HISTORIC PRESERVATION ITEMS.
THE HISTORIC PRESERVATION CASES BELOW WERE VOTED ON USING THE
BLOCK VOTE SYSTEM.
26HP2157: In Matoaca Magisterial District, Beach Station, LLC requests the removal of
historic landmark designation for the parcel (3.328 acres) located at 11410 Beach Road
while maintaining designation solely on the George Perdue House. This case amends the
original historic designation case 08HP0153. The property is zoned Agricultural, and the
Comprehensive Plan land use guidance suggests Light Business uses. Tax ID 745-654-
8256.
Page 11 of 218
8 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Ms. Richardson, the Commission resolved to
recommend approval of Case 26HP2157.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
26HP2168: In Matoaca Magisterial District, Beach Station, LLC requests the removal of
historic landmark designation for the parcel (5.211 acres) located at 11400 Beach Road
while maintaining designation solely on the Perdue-Mitchell House. This case amends the
original historic designation case 08HP0154. The property is zoned Agricultural, and the
Comprehensive Plan land use guidance suggests Light Business uses. Tax ID 746-654-
1071.
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Page 12 of 218
9 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Ms. Richardson, the Commission resolved to
recommend approval of Case 26HP2168.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
C. CONSENT ITEMS.
THE CONSENT CASES BELOW WERE VOTED ON USING THE BLOCK VOTE SYSTEM.
During the public hearing of the consent agenda items, three (3) cases were moved to the
discussion agenda at the request of citizen speakers that expressed opposition. Mr. Jerry
Turner also spoke, not regarding a specific case but to express his concern about the use
of block votes for consent items, stating that he believed the practice was inappropriate.
24SN1350: In Bermuda Magisterial District, East Hundred Road Self-Storage is a request
for conditional use to permit a self-storage facility and amendment of zoning district map in
the Corridor Commercial (CC) District on 4.45 acres known as 540 East Hundred Road. The
Comprehensive Plan suggests the property is appropriate for Arterial Business use. Tax IDs
817-652-5138, 6725, and 8321.
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
Page 13 of 218
10 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to recommend
approval of Case 24SN1350 subject to the Conditions.
CONDITIONS
Staff Note: GPINs referenced in the conditions can be found on the Current Zoning Map.
1. Conceptual Plan. The Property shall generally conform with the proposed improvements
shown on Exhibit A, titled “East Hundred Road Concept Plan” and dated June 17, 2026,
unless otherwise approved at the time of plans review by the Director Planning. (P)
2. Conceptual Building Elevations. The buildings shall be designed and constructed in a style,
manner, and appearance substantially similar to the elevations attached as Exhibit B. (P)
3. Phasing. The self-storage facility shall not receive certificate of occupancy prior to the two
(2) retail buildings depicted on the Conceptual Plan unless otherwise approved at the time
of site plan by the Director of Planning. (P)
4. Buffer Along Rear Property Line. There shall be a 100-foot buffer along the rear (northern)
property line as shown on Exhibit A. (P)
5. Masonry Screening Wall. An eight (8) foot wall designed to match the self-storage building
exterior shall be constructed as shown on Exhibit A at the time of construction of the self-
storage building. (P)
6. Opaque Glass. Any glass on the second and third levels of the self-storage facility shall be
opaque in a manner which will obstruct the view of interior storage units. (P)
7. Emergency Police Access. An electronic pushbutton keypad shall be installed at facility’s
main vehicular entrance gate for emergency police access. Applicant shall contact
Chesterfield County Emergency Communications Center (ECC) Operations Manager to
establish a unique, four-digit, police-only emergency access code prior to the certificate of
occupancy being issued. (Police)
8. Security Surveillance. The applicant/owner/operator shall be responsible for the installation,
operation, and maintenance of a functioning security camera and video system of
professional grade and quality, and rated for the surveillance of exterior self-storage (or
equivalent) operations. This security system shall, at a minimum, include exterior
surveillance camera(s) to monitor all vehicular property and customer building entrance(s).
Network video recorder (NVR)/Digital Video Recorder (DVR) shall be capable of exporting
video footage in proprietary and non-proprietary formats, unless otherwise approved by
Police Department. (Police)
Page 14 of 218
11 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
9. Access Control. Access to the storage area will be monitored via controlled gate access
requiring unique tenant codes at the entry keypad and/or card reader. All tenant entry to the
storage building and area will be recorded to include timestamps, and all gate-controlled
access points and loading areas will be under 24/7 NVR cloud-recorded video monitoring.
(Police)
10. Lighting. Full cut-off, photocell-activated, minimum 70 CRI-rated, LED luminaries shall
illuminate:
a. Sidewalks and parking with a minimum illumination level of 1.5 foot-candles,
measured at grade.
b. Loading areas with a minimum maintained illumination level of 5.0 foot-candles, as
measures at grade. (Police)
11. Landscaping.
a. Two (2) rows of evergreen trees, planted six (6) feet on center, staggered, with a
double row of shrubs, planted four (4) feet on center, staggered, shall be planted
within the front setback from Route 10.
b. Building foundation plantings shall not have natural, mature growth habits that
exceed three (3) feet in height. (P and Police)
12. Utilities.
a. Public water and wastewater shall be used.
b. The Applicant shall grant a sixteen (16) foot sanitary sewer easement and a ten (10)
foot temporary construction easement along East Hundred Road outside of the
ultimate right-of-way. Easements shall be unencumbered by buffers or planted
trees.
c. The on-site public wastewater system shall be designed with sufficient depth to
serve the natural service area, including adjacent property identified as GPIN 817-
652-9345. A wastewater line extension with terminal manhole within a public
wastewater easement, shall be provided to the southern property line for the GPIN
817-652-9345, such that on-site improvements are not disturbed by future
extensions. (U)
13. Hours of Operation for Self-Storage Use. Hours of operation for the self-storage use shall
be limited to 6:00 a.m. until 9:00 p.m. (P)
14. Access. Direct vehicular access to/from the Property to East Hundred Road (Route 10)
shall be limited to one (1) access with the exact location approved by the Transportation
Department and Planning Department. If required by the Transportation Department at time
of plans review, prior to final site plan approval an access easement, acceptable to the
Transportation Department, shall be recorded across the Property to provide shared use of
the Route 10 access with the adjacent property(ies) to the east. (T and P
Page 15 of 218
12 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
15. Dedication. Prior to the final site plan approval or within sixty (60) days from a written
request by the Transportation Department, whichever occurs first, one hundred (100) feet
of right-of-way along the north side of East Hundred Road (Route 10), measured from
the centerline of that part of the roadway immediately adjacent to the Property shall be
dedicated, free and unrestricted, to and for the benefit of Chesterfield County (CDOT). (T)
16. Transportation Improvements. In conjunction with initial development and prior to the
issuance of any certificate of occupancy, the following road improvements shall be
completed by the Owner/Developer with any modification to the design and lengths specified
below approved by the Transportation Department. If any of the road improvements
identified below are provided by others, as determined by the Transportation Department,
then the specific road improvement shall no longer be required.
a. Construction of an additional lane of pavement along the westbound lanes of East
Hundred Road (Route 10) for the entire Property frontage with any modifications
approved by the Transportation Department.
b. Construction of additional pavement along the westbound lanes of Route 10 at the
approved access to provide a separate right tum lane.
c. Construction of additional pavement along the eastbound lanes of Route 10 at the
existing uncontrolled median break/crossover located east of the Property to
provide an adequate left tum lane.
d. Construction of a VDOT standard sidewalk along the Property's frontage along
Route 10.
e. Dedication to Chesterfield County, free and unrestricted, of any additional right-of-
way (or easements) required for the improvement identified above. (T)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
26SN2068: In Clover Hill Magisterial District, 7-11 Convenience Store Amendment is a
request to amend zoning approval (Case 03SN0214) to modify permitted uses relative to
gasoline sales and amendment of zoning district map in a Suburban Community (SC) District
on 1.55 acres known as 14600 Time Square Drive. The Comprehensive Plan suggests the
property is appropriate for Residential Neighborhood 2 use (2.0 units per acre or less). Tax
ID 719-687-1624.
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
Page 16 of 218
13 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to recommend
approval of Case 26SN2068 subject to the Conditions.
CONDITIONS
Proffered Condition 1 of Case 03SN0214 is hereby deleted in its entirety and replaced with
the following condition:
1. Uses. Uses. In addition to those uses permitted by right or with restrictions in the
Convenience Business (C-1) District, the following use shall be permitted:
a. Gasoline sales, including diesel fuel sales in conjunction with a permitted use. A
maximum of four (4) pump islands containing a total of no more than eight (8) fueling
stations (a maximum of four (4) pump islands, each having two (2) fueling stations
and no more than three (3) fueling nozzles at each fueling station) shall be
permitted.
b. Motor vehicle wash in conjunction with a use, provided such use is limited to service,
automatic, single-bay operation. (P)
Staff Note: All other proffered conditions of Case 03SN0214 shall remain in full force and
effect.
The following conditions shall also apply to the Property:
2. Elevations. The convenience store shall be built in accordance with the elevations dated
July 13th, 2026, as shown in Exhibit B. (P)
3. Gas Canopy. The gas canopy columns shall be wrapped in brick matching the same
materials used in the convenience store and car wash as shown in Exhibit B (P)
4. Security.
Page 17 of 218
14 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
a. High visibility pictographic video surveillance signs shall be posted on exterior
customer doors, the car wash building, and parking lot light poles.
b. If not operational 24/7, the business shall install a professional, centrally monitored,
cell-based, door contact and motion-activated, audible security alarm system to
monitor the building.
c. Video management system shall meet the following criteria:
i. NDAA compliant and/or FIPS validated
ii. IP-based
iii. 1080p interior and exterior cameras
iv. Minimum 30-day video retention
v. 24-hour operation
vi. On-site video monitor
vii. Proprietary and non-proprietary video export formats
viii. Full-lite exterior building doors shall utilize laminated glass construction that
meets UL 972 standard for Burglary Resisting Glazing Material or doors
shall include a professionally installed, minimum 10-mil-thick break
resistant film.
d. Roof ladder shall be located interior to the building.
e. At time of site plan submission, applicant shall provide CCPD’s CPTED Planner a
security plan which details:
i. Security alarm system manufacturer and model information, system
specifications/details, duress capabilities, and monitoring center
information
ii. Exterior and interior video surveillance camera locations and viewing
angles; and
iii. Security camera cut sheets. (Police)
5. Lighting. All existing freestanding lighting shall be maintained as approved by site plan
08PR0309. (P and Police)
6. Landscaping. Building foundation plantings shall not have natural, mature growth habits that
exceed three feet (3’) in height. (Police)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
26SN2080: In Matoaca Magisterial District, Charleston Landing Rezoning is a request to
rezone from Suburban Community (SC) to Semi-Urban Neighborhood (SU) and amendment
of the zoning district map for property lying approximately 550 feet northwest of the
intersection of Woolridge Road and Magnolia Green Parkway, known as 6700 Magnolia
Green Parkway. The 60.2 acre property is proposed for a maximum development of 93 units.
Page 18 of 218
15 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
The Comprehensive Plan suggests the property is appropriate for Residential Neighborhood
2 use (2.0 units per acre or less). Tax ID 696-673-0860.
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to recommend
approval of Case 26SN2080 subject to the Proffered Conditions.
PROFFERED CONDITIONS (7/13/2026)
The property owners and applicant in this rezoning case, pursuant to Section 15.2-2298 of
the Code of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County
(the “Zoning Ordinance”), for themselves and their successors or assigns, proffer that the
property under consideration (the “Property”) will be developed according to the following
proffers if, and only if, the rezoning request submitted herewith is granted with only those
conditions agreed to by the owners and applicant. In the event this request is denied or
approved with conditions not agreed to by the owners and applicant, the proffer shall
immediately be null and void and of no further force or effect.
These Proffered Conditions include one (1) exhibit attached hereto:
Exhibit A: Shadow Creek – Section 2, Magnolia Green, prepared by Timmons Group, dated
June 9, 2026 (“Conceptual Plan”)
1. Conceptual Plan. The Property shall be developed in general conformance with the
Conceptual Plan. The Conceptual Plan is conceptual in nature and may vary based on the
final site plan depending on the final soil studies, RPA lines, road design, lot locations, lot
line locations, amenity locations, setback location and depth, easement location and depth,
waterline location, VDOT requirements, BMP design and location, and other design or
Page 19 of 218
16 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
engineering reasons. Any substantive changes that do not relate to the prior sentence may
be approved by the Planning Director at the time of plans review, upon the Director finding
that the substantive changes are generally in keeping with the spirit and intent of the
Conceptual Plan. In the event of any conflict between information shown on the Conceptual
Plan and these Proffered Conditions, these Proffered Conditions shall control. (P)
2. Density. The number of dwelling units shall be limited to a maximum of 90. (P)
3. Environmental Engineering.
a. Super Silt Fence, or an alternative as approved by the Department of Environmental
Engineering, shall be provided as a perimeter control in locations adjacent to RPA’s,
streams and wetlands.
b. Sediment traps and sediment basins sized at least 25% larger than the minimum Virginia
Stormwater Handbook’s standard shall be provided.
c. Anionic PAM, Flexible Growth Medium and/or a County-approved equivalent shall be
applied to denuded areas at final stabilization in the locations shown on plans approved
by Environmental Engineering at the time of plans review.
d. The maximum post-development discharge rate for the 100-year storm shall be based
on the maximum capacity of the existing facilities downstream, and shall not increase the
recorded and /or established 100-year backwater and /or floodplain. On-Site detention of
the post-development 100-year discharge rate to below the pre-development 100-year
discharge rate may be provided to satisfy this requirement. (EE)
4. Police.
a. CBU Lighting. Full cut-off, photocell-activated, minimum 70 CRI-rated LED luminaires
shall illuminate areas within 20 feet of the cluster mailbox units (CBUs) with a minimum
maintained illumination level of 0.5 foot-candles, as measured at grade, but this
requirement may be modified to meet VDOT requirements. (Police)
5. Road Cash Proffer.
a. The applicant, sub-divider, or assignee(s) (the “Developer”) shall pay $9,400.00 for each
single-family dwelling unit to Chesterfield County for road improvements within the
service district for the property (“Road Cash Proffer Payment”).
b. Each Road Cash Proffer Payment shall be made prior to the issuance of a certificate of
occupancy for a dwelling unit unless state law modifies the timing of the payment.
Should Chesterfield County impose impact fees at any time during the life of the
development that are applicable to the property, the amount paid in cash proffers shall
be in lieu of or credited toward, but not be in addition to, any impact fees, in a manner
determined by the County.
Page 20 of 218
17 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
c. At the option of the Applicant, or assignee(s), the Road Cash Proffer payments may be
reduced for the cost of off-site road improvements, provided by the applicant, sub-
divider, or assignee(s), as determined by the Transportation Department. (Budget)
6. Dedication – Powhite Parkway (extended). In conjunction with the recordation of the initial
subdivision plat, or within sixty (60) days after a written request by the Transportation
Department, whichever occurs first, variable width right-of-way and/or easements for the
Powhite Parkway (extended) located only within the 200’ limited access road setback (the
“Setback”), as measured from the right-of-way line for Powhite Parkway (extended) as of the
date of these proffered conditions, as illustrated on the Conceptual Plan, but not closer than
ten (10) feet from the lot lines shown on the Conceptual Plan, shall be dedicated, free and
unrestricted (except for existing easements benefiting the County), to and for the benefit of
Chesterfield County or VDOT. If Powhite Parkway (extended) design/alignment is modified,
as determined by the Transportation Department, without necessitating the right-of-way
dedication and/or easement(s), the Transportation Department may waive this dedication
obligation, or portion thereof. If requested by the Developer and accepted by the
Transportation Department, the right-of-way dedications may be phased in accordance with
an approved phasing plan. (T)
7. Limited Access Road Setback. In the event that the 200’ Limited Access Road setback or
similar 200’ setback (“Setback”) is applied to Powhite Parkway (extended), then the setback
shall be measured from the existing consistent arc line, in alignment with Powhite Parkway
(extended) (the “Arc Line”), and not measured from areas being dedicated, being used for
stormwater control measures or being used for other accessory uses related to Powhite
Parkway (extended). This Arc Line is generally illustrated on the Conceptual Plan. No noise
study shall be required of the Developer for the Powhite Parkway (extended) right-of-way
and/or any County water and/or sewer lines and easements encroachments into the
Setback. (T & P)
8. Exterior Facades.
a. Roof materials shall be architectural/dimensional asphalt composition shingle or better
with a minimum 30-year warranty, pre-finished or real copper, or standing seam metal
roof.
b. Acceptable siding materials include brick, stone, masonry, fiber cement siding (such as
HardiePlank, HardieShingle, and HardieTrim), engineered wood siding (such as LP
SmartSide), or high-grade vinyl (a minimum of .044” nominal thickness as evidenced by
manufacturer’s printed literature). Dutch lap, plywood, and metal siding are not permitted.
Any materials may be used for parapets, cornices, surrounds, trim, architectural
decorations, and design elements. (P)
9. Porches and Stoops. Front stoops and porches shall be constructed with continuous
foundation walls, or masonry piers to match the foundation of the home. (P)
Page 21 of 218
18 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
10. Garage Doors. A minimum of three (3) enhanced features shall be provided on the garage
door. Enhanced features shall include windows, raised panels, decorative panels, arches,
ornamental hardware or other architectural features on the exterior that enhance the entry
(i.e. decorative lintels, shed roof overhangs arches, columns, keystones, eyebrows, etc.).
Flat panel garage doors shall be prohibited. (P)
11. Heating, Ventilation and Air Conditioning (HVAC) Units and Generators. HVAC units and
generators installed as fixtures shall be screened initially from view of roads by landscaping
or low maintenance material, as approved by the Planning Department. (P)
12. Foundation Plantings. Foundation planting beds shall be required along the entire front
façade of buildings excluding garages, stairs and walkways accessing porches and patios.
Foundation planting beds that extend a minimum of one third (1/3) of the length of the side
elevation (as measured from the front corner of the unit) are also required on building side
elevations that are adjacent to public streets. Foundation planting beds shall be a minimum
of 4’ deep, and shall contain a minimum of fifty (50) percent evergreen material with one (1)
shrub per three (3) linear feet wide as measured from the unit foundation. Unit corners shall
be visually softened with vertical accent shrubs (4’-5’ at the time of planting) or small
evergreen trees (6’-8’ at the time of planting). An alternative foundation planting standard or
an alternative foundation bed depth may be approved by the Planning Director at the time
of plans review for some or all of the buildings in the project. (P)
13. Lighting. Any lighting requirements for sidewalks and driveways shall be met with a post light
placed in the front yard with an additional carriage light near the garage door. (P)
14. Architecture. The architectural appearance of single-family detached dwellings shall
generally conform with any one or more of the following: (i) the architectural appearance of
dwelling units constructed within the age-targeted neighborhoods of Magnolia Green
(“Existing Architectural Appearance”) or (ii) another architectural appearance approved by
the Planning Director at the time of plans review and approval or subsequent thereto upon
request by the owner of the property, upon the Director finding that the new elevations are
generally in keeping with the spirit and intent of the Existing Architectural Appearance. (P)
15. Variation in Unit Front Elevations. Single-family detached dwelling units with the same front
elevation (including materials and colors) may not be located next to or across the street
from another. Variation in the front elevation may not be achieved by simply mirroring the
façade, but may be accomplished by providing at least three (3) of the architectural changes
listed below:
a. Adding masonry elements above the required foundation masonry amount.
b. Changing the location of roof type, roof line, front facing gable(s) and/or dormers.
Page 22 of 218
19 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
c. Changing the style of roof type, roof line, front facing gable(s) and/or dormers.
d. Providing varied siding application using horizontal siding, shake siding or board and
batten siding.
e. Providing varied color application.
f. Using a front porch or a covered stoop.
g. Adding projections such as bay/box windows, second floor balconies, or accent roofs.
h. Different window fenestration design.
i. Any other element of architectural variation as approved by the Director of Planning. (P)
16. Driveways. All private driveways shall be hardscaped (i.e. constructed from concrete,
pavers, or other masonry materials). (P)
17. Front Walks. Front walks shall be provided from the driveway, street or sidewalk to the front
entrance of a dwelling. All front walks shall be a minimum of three (3) feet in width and
hardscaped (i.e. constructed from concrete, pavers, or other masonry materials). (P)
18. Garages.
a. A front-loaded garage shall not project further than five (5) feet from a portion of a front
porch or a front stoop closest to the frontage road.
b. If a dwelling does not include a front porch or a front stoop, then a front-loaded garage
shall not project further than five (5) feet from the front elevation of the dwelling closest
to the frontage road. (P)
19. Foundation Masonry. There shall be a minimum vertical height of eighteen (18) inches of
brick, brick veneer, stone, stone veneer, or other masonry material approved by the Planning
Director installed above grade for units with slab-on-grade foundations on all front, side, and
rear elevations. All other foundations shall be faced entirely of brick, brick veneer, stone,
stone veneer, cultured stone, and/or other masonry materials; except (i) for units where the
grade drops along the façade foundation this required masonry may step down at eighteen
inch (18”) intervals limited to two step downs, and (ii) for units with a walkout basement siding
may continue to the ground level of a walkout basement (aa) if there is a window or door
that shows the presence of a basement floor or (bb) if there is a first floor deck. Synthetic or
natural stucco foundations may be permitted for facades constructed entirely of stucco. (P)
20. Public Waterline. The Applicant shall dedicate a thirty (30) foot wide easement for a public
waterline in the general location shown by the orange line labeled “30” Public Water
Page 23 of 218
20 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Easement” on the Conceptual Plan, unless a different location is approved at the time of
plans review by the Director of Utilities. (U)
21. Public Utilities. Public water and wastewater shall be used. (U)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
26SN2088 (Deferred from 06/16/2026): In Bermuda Magisterial District, Womack Road
Rezoning is a request to rezone from Agricultural (A) and Transition Residential (TR) to
Semi-Urban Neighborhood (SU) and amendment of zoning district map for property lying
approximately 80 feet off the west side of Womack Road, 205 feet north of West Hundred
Road known as 12222 Womack Road. The 0.68 acre property is proposed for a maximum
development of 1 dwelling unit. The Comprehensive Plan suggests the property is
appropriate for Residential use (7.0 units per acre or more). Tax ID 786-653-0956.
Mr. Steve Donohoe presented the case. He reported that staff had received no public
opposition to this case and that staff had received agreement to the conditions from the
applicant.
There was opportunity for questions by the Commissioners for Mr. Donohoe. There were no
questions.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Mr. Sloan, the Commission resolved to recommend
approval of Case 26SN2088 subject to the Conditions.
PROFFERED CONDITIONS (6/3/2026)
Staff Note: GPINs referenced in the proffered conditions can be found on the Current Zoning
Map.
1. Utilities. The public water and wastewater systems shall be used for 12222 Womack Road.
(U)
Page 24 of 218
21 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
2. Wastewater Easement. The Applicant shall provide a sixteen (16) foot permanent sewer
easement and ten (10) foot temporary construction easement across the northern portion of
the property connecting to the existing sewer and easement to provide for future service for
GPIN 786-653-0347 (12224 Womack Road) as shown on the Zoning Exhibit. (U)
3. Water Easement. The Applicant shall provide a ten (10) foot private water service easement
from the right-of-way of Womack Road to the property boundary of GPIN 786-653-0347
(12224 Womack Road) as shown on the Zoning Exhibit. (U)
Staff Note: If a public water service is needed for 12224 Womack Road in the future, the
owner of 12224 Womack Road will need to request a Private Water Exception from Utilities
to utilize the private water service easement referenced above.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
D. DISCUSSION ITEMS.
25SN1184 (Deferred from 06/16/2026): In Matoaca Magisterial District, Spring Creek
Baptist Church Rezoning is a request to rezone from Agricultural (A) to Suburban
Community (SC) and amendment of zoning district map known as 5200 Woolridge Road.
The 7.45 acre property is proposed for a maximum development of 12 dwelling units. The
Comprehensive Plan suggests the property is appropriate for Residential Neighborhood 2
use (2.0 units per acre or less). Tax IDs 716-680-Part of 9777-00001 and Part of 9777-
00002.
Mr. Ryan Ramsey presented the case.
There was opportunity for questions by the Commissioners for Mr. Ramsey.
There were no questions.
Mr. Dave Anderson with Timmons Group came forward on behalf of the applicant and gave
a brief presentation on the case.
There were no questions for Mr. Anderson.
Ms. Hardin opened the Public Hearing.
Page 25 of 218
22 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. Ed Baumgartner, Mr. Mark Staver, Mr. Jerry Turner, Mr. Neal Fleenor, and Mr. Marty
Bland each spoke in opposition to the request. They voiced shared concerns, including
strong objections to routing construction and residential traffic through adjacent
neighborhoods. Residents also raised environmental issues related to potential impacts on
wetlands, retention ponds, and runoff into Swift Creek Reservoir. Many questioned whether
buffers would be maintained, citing past clear‑cutting, and feared declines in property values
due to the loss of wooded areas, increased noise, and greater visibility of new homes.
Several noted that existing HOA amenities are already strained and that additional homes
would worsen overcrowding. Some expressed feeling misled by sales staff and developers
about long‑term land use, and several residents stated they would prefer the land remain
natural or be preserved rather than developed.
Mr. Chris Bobber came forward and shared the same concerns; however, he was neither in
support nor opposition.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Mr. Anderson came forward and stated that throughout the process, including the four
deferrals of this case, he had not previously received many of the concerns expressed that
evening. In addressing citizen participation, he noted that multiple meetings had been held
and emphasized that he had been available to answer questions. He concluded by asking
the Commissioners to forward a recommendation of approval to the Board of Supervisors.
Mr. Sloan led the discussion. In response to a question from Mr. Sloan, Mr. Anderson stated
it was not feasible to construct a two (2) way road to accommodate construction traffic or
reroute citizen traffic. As a compromise, they were able to have the construction traffic use
property owned by the church to allow trucks to turn around and come out to a stop light,
which is much safer for everyone on the road.
Mr. Sloan asked the Deputy County Attorney about the recent guidance from the General
Assembly regarding churches pursuing residential projects. Mr. Fulwider explained that the
General Assembly now allows religious and other non‑profit organizations to build residential
projects by-right, without requiring zoning approval.
Mr. Ramsey added that the size of the property is approximately seven and a half (7.5) acres
and would allow for seventy (70) to eighty (80) units per acre if desired. A much higher
density than the proposed twelve (12) units.
Mr. Sloan expressed empathy for the citizens who spoke during the public hearing. He
emphasized the importance of residents checking the zoning of the surrounding area before
Page 26 of 218
23 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
purchasing a home. While Mr. Sloan stated he would not impose a new condition, he strongly
encouraged Mr. Anderson to revisit the transportation plan before the case moves forward
to the Board of Supervisors.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1184 subject to the Proffered Conditions.
PROFFERED CONDITIONS (6/3/2026)
The property owner and Applicant in this case, pursuant to Section 15.2-2298 of the Code
of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County, for
themselves and their successors and assigns, proffer that the property under consideration
for rezoning (“the Property”) will be developed according to the following proffers if, and
only if, the request submitted herewith is granted with only those conditions agreed to by
the owner and Applicant. In the event this request is denied or approved with conditions
not agreed to by the owner and Applicant, the proffers shall immediately be null and void
and of no further force or effect.
The proffers below are provided for Tax IDs 716680947700001 and 716680947700002 for
rezoning case 25SN1184. The proffers agreed to herein are believed by the owner and
Applicant to be reasonable, according to current laws of the Commonwealth of Virginia.
1. Exhibits. The following, prepared by Timmons Group, shall constitute the Exhibits of this
rezoning.
a. Exhibit A – Concept Layout – Dated February 25, 2026
b. Exhibit B – Zoning Limits – Dated February 25, 2026
c. Exhibit C – Precedent Elevations – Dated February 25, 2026 (P)
2. Road Cash Proffers.
a. The applicant, subdivider, or assignee(s) shall pay $9,400 for each single-family
unit to Chesterfield County for road improvements within the service district for the
property (the “Cash Proffer Payments”).
b. Each payment shall be made prior to the issuance of a certificate of occupancy for
each dwelling unit unless state law requires modification of the timing of the
payment. Should Chesterfield County impose impact fees at any time during the
life of the development that are applicable to the property, the amount paid in cash
proffers shall be in lieu of or credited toward, but not in addition to, any impact fees,
in a manner determined by the county. (Budget)
3. Utilities. Public water and wastewater systems shall be used. (U)
4. Environmental.
Page 27 of 218
24 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
a. Super Silt Fence, or an alternative as approved by the Department of Environmental
Engineering, shall be provided as a perimeter control in locations where standard
silt fence would have been required.
b. Sediment traps and sediment basins sized at least 25% larger than the minimum
Virginia Stormwater Management Handbook’s standard shall be provided.
c. Anionic PAM, Flexible Growth Medium and/or a County-approved equivalent shall
be applied to denuded areas during construction and at final stabilization in the
locations shown on plans approved by Environmental Engineering at the time of
plans review.
d. The maximum post-development discharge rate for the 100-year storm shall be
based on the maximum capacity of the existing facilities downstream and shall not
increase the recorded and /or established 100-year backwater and /or floodplain.
On-Site detention of the post-development 100-year discharge rate to below the
pre-development 100-year discharge rate may be provided to satisfy this
requirement.
e. Impervious areas created from development of the Property shall not sheet flow
through the adjacent lots in The Landing at Swift Creek subdivision. (EE)
5. General Conditions.
a. Density. The maximum overall density shall be no more than twelve (12) single
family lots.
b. Landscape & Buffers.
i. Buffers.
1. A twenty (20) foot wide undisturbed buffer shall be provided as
depicted in Exhibit A.
2. All healthy existing vegetation within the buffers shall be retained.
Buffers shall be designated on construction plans and orange
safety fencing shall be used along buffers within twenty-five (25)
feet of land disturbance activities. Prior to any land disturbance on
the Property, all buffers shall be marked with tree protection tape.
ii. Stormwater Perimeter Yard.
1. Buildings shall be setback a minimum of 50 feet from the 100-year
water surface elevation of basins. This setback shall be shown on
the subdivision record plat.
2. Should reduced vegetative perimeter yards be granted at site plan
approval per Sec 19.2-44, perimeter yards shall include enhanced
landscaping to be approved by the Environmental Engineering
Department.
c. Lighting. Except where otherwise stated, lighting shall comply with Section 19.2-38
of the Zoning Ordinance. Exterior lighting shall meet the following standards:
i. Lamp Posts.
Page 28 of 218
25 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
1. One lamp post shall be provided for each single-family lot and shall
generally be located in the front yard near the end of the driveway.
2. The design of such lamp posts shall be consistent throughout the
Property.
ii. Other Exterior Lighting.
1. Freestanding lights shall not exceed a height of 20 feet above the
finished grade.
2. Building mounted lights for individual dwelling units shall be limited
to lighting necessary to illuminate entrances into the dwelling.
d. Lot Standards.
i. Fencing. Fencing shall be constructed of decorative maintenance-free
material. No chain link fencing shall be permitted.
ii. Front Yards. Except for the foundation planting bed, all front and corner side
yards shall be sodded and irrigated.
iii. Front Foundation Planting Beds. Foundation planting is required along the
entire front façade of all the units and shall extend along all sides facing a
street. Foundation planting beds shall be a minimum of 4’ wide from the unit
foundation. Planting beds shall be defined with a trenched edge or suitable
landscaping edging material. Planting shall include medium shrubs spaces
a maximum of four (4) feet apart and may also include spreading
groundcovers. Unit corners shall be visually softened with vertical accent
shrubs (4’-5’) at the time of planting.
iv. Walkways. A minimum of four (4) foot wide hardscaped front walk shall be
provided from the driveway to each dwelling unit.
v. Driveways. All private driveways serving residential uses shall be brushed
concrete, stamped concrete, exposed aggregate concrete, decorate
pavers, or asphalt.
vi. Architecture.
1. Elevations. Unless significant deviations are approved by the
Planning Director during subdivision plan review, the architecture
treatment of the single-family dwelling units shall be consistent
(incorporating similar, but not necessarily identical design
elements, style and materials) with the precedent images shown in
Exhibit C.
2. Elevation Repetition. Dwelling units with the same elevation, not
including the same style (i.e. Craftsman, Farmhouse, etc.), shall
not be located adjacent to, directly across from, or diagonally
across from each other on the same street.
3. Exterior Facades. Acceptable siding materials include brick, stone,
stucco (E.F.I.S.), shake shingle or scallops, board and batten,
horizontal lap exclusive of dutch lap, horizontal board and batten
Page 29 of 218
26 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
or a combination thereof. Siding may be manufactured from natural
wood or cement fiber board, including, but not limited to,
hardiplank. Plywood, vinyl, and metal siding are not permitted;
provided, however, that vinyl material shall only be permitted for
trim or soffits. Additional siding requirements:
a. Synthetic stucco (E.F.I.S.) siding shall be finished in
smooth, sand, or level texture. Rough textures are not
permitted.
4. Foundations. All exposed portions of the foundation of each new
dwelling unit shall be faced with brick or stone veneer.
5. Porches and Stoops.
a. Front Porches. All front entry stoops and front porches
shall be constructed with continuous masonry foundation
wall or on 12”x12” masonry piers. Extended front porches
shall be a minimum of five (5) feet deep. Space between
piers under porches shall be enclosed with lattice panels.
Handrails and railings shall be finished pained wood or
mental railing with vertical pickets of swan balusters.
Pickets shall be supported on top and bottom rails that
span between the columns.
b. Front Porch Flooring. Porch flooring may be concrete,
exposed aggregate concrete, or a finished paving material
such as stone, tile or brick, finished (stained dark) wood,
or properly trimmed composite decking boards. Unfinished
treated wood decking is not acceptable. All front steps
shall be masonry to match the foundation.
6. Roofing. Roofing material shall be dimensional architectural
shingles or better with a minimum 30-year warranty.
7. Front Loaded Garages.
a. Front loaded garages shall be located no closer to the
street than the front façade of the dwelling unit.
b. Front loaded, and corner side loaded garages shall use an
upgraded garage door. An upgraded garage door is any
door with a minimum of two (2) enhanced features.
Enhanced features shall include windows, raised panels,
decorative panels, arches, hinge straps or other
architectural features on the exterior that enhance the
entry (i.e. decorative lintels, shed roof overhangs, arches,
columns, keystones, eyebrows, etc.). Flat panel garage
doors are prohibited.
8. Heating, Ventilation and Air Conditioning (HVAC) Units, and Whole
House Generators. Units shall initially be screened from view by
landscaping or low maintenance material.
Page 30 of 218
27 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
9. Detached Garages and Accessory Structures. Detached garages
and accessory structures shall be architecturally comparable and
employ comparable materials to that of the dwelling unit.
10. Fireplaces, Chimneys, and Flues.
a. Chimneys. Masonry fireplace chimney cases shall be
constructed of brick or stone, or with a façade matching the
adjacent façade material.
b. Direct Vent Fireplaces. Direct vent gas fireplace boxed
which protrude beyond the exterior face of the unit, are not
permitted on front facades. All the exterior materials and
finishes used to enclose the fireplace box must match the
adjacent façade material. (P and EE)
6. Conceptual Plan. The site shall be developed in general conformance with the conceptual
plan depicted as Exhibit A attached hereto entitled “Concept Layout” prepared by Timmons
Group, and dated February 25, 2026 (known as the “Conceptual Plan”). The Conceptual
Plan is conceptual in nature, and the final subdivision plat may vary based on field studies
to include location of wetlands, soil conditions, final road design, and other engineering and
design considerations. (P)
7. Construction Traffic. During the site construction phase of developing the Property, which
includes grading, road construction, and utility and other site infrastructure, all large
construction vehicles (including concrete trucks, dump trucks, and material delivery vehicles)
shall enter the Property only from Woolridge Road via Spring Creek Baptist Church Entrance
Road and shall not enter the Property from the subdivisions of Woolridge Landing and/or
The Landing at Swift Creek. The one-way construction access road through the church to
the Property shall be shown and approved with the subdivision construction plans.
Empty construction vehicles, along with trucks hauling cleared and grubbed vegetation, shall
be permitted to exit the Property onto Winding Waters Drive, but at no time shall Winding
Waters Drive or Hidden Falls Drive be used for inbound construction traffic for large
construction vehicles during site construction.
The developer of the Property shall take all reasonably necessary measures to enforce this
restriction, including but not limited to posting signage on the Property. Signs shall be posted
in English and Spanish on a 2′ x 4′ sign, clearly legible from the public right-of-way at the
entrance into the development from Woolridge Road as well as the future road connection
onto Winding Waters Drive. Signs shall be maintained by the owner/developer and shall
remain until site construction activity is complete, as determined by the Planning
Department. (P)
Ms. Hardin aye
Page 31 of 218
28 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
25SN1354: In Bermuda Magisterial District, Elder Property Rezoning & Adjustments is a
request to rezone from Agricultural (A), Semi-Urban Neighborhood (SU) and Corridor
Commercial (CC) to Semi-Urban Neighborhood (SU) with adjustments to ordinance
requirements for development standards plus a waiver to connectivity and amendment of
zoning district map on property located at the southwest corner of East Hundred Road and
Point of Rocks Road, known as 2600 East Hundred Road. The 61.45 acre property is
proposed for a maximum development of 222 dwelling units. The Comprehensive Plan
suggests the property is appropriate for Community Mixed Use. Tax IDs 826-641-8661; 826-
642-6299 and 7751; 827-641-0082; 827-642-3069, 4016 and Part of 6519; 828-641-Part of
0291; and 832-642-Part of 8718.
Mr. Rich Saunders presented the case.
There was opportunity for questions by the Commissioners for Mr. Saunders.
There were no questions.
Mr. Jeff Geiger came forward on behalf of the applicant and gave a brief presentation on the
request.
There were no questions for Mr. Geiger.
Ms. Hardin opened the Public Hearing.
Mr. Robert Brown, Mr. Jerry Turner, and Ms. Jenny Castle came forward and expressed
their concerns. Each included density, infrastructure, and traffic.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Mr. Geiger came forward in rebuttal and addressed the concerns of traffic and infrastructure
by providing the plans the developer has in place to mitigate any negative impacts. He added
that these homes will serve the people in the County who wish to live closer to their jobs.
Mr. Sloan led the discussion. He stated he read all comments provided, including several in
support. Mr. Sloan stated that with the work the developer has done, the end result will be a
positive one.
Page 32 of 218
29 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Mr. Petroski commented on infrastructure and said commercial establishments like grocery
stores will not build in a community before the density is there. In order to receive desired
services, the residents must already be in place.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1354 Request 1 subject to the Proffered Conditions.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1354 Request 2 subject to the Proffered Conditions
PROFFERED CONDITIONS (7/9/2026)
Staff Note: GPINs referenced in the proffered conditions can be found on the Current Zoning
Map.
The property owners and applicant in this rezoning case, pursuant to Section 15.2-2298 of
the Code of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County
(the “Zoning Ordinance”), for themselves and their successors or assigns, proffer that the
property under consideration (the “Property”) will be developed according to the following
proffers if, and only if, the rezoning request submitted herewith is granted with only those
conditions agreed to by the owners and applicant. In the event this request is denied or
approved with conditions not agreed to by the owners and applicant, the proffer shall
immediately be null and void and of no further force or effect.
These Proffered Conditions include three (3) exhibits attached hereto:
Exhibit A: “Elder Property” prepared by Townes Site Engineering, dated July 7, 2026
(“Conceptual Plan”).
Exhibit B: Single Family Detached Home Elevations, dated December 22, 2025
Exhibit C: “25SN1354 – ELDER PROPERTY – UTILITIES EXHIBIT” dated June 24, 2026
(“Utilities Exhibit”)
1. Conceptual Plan. The Property shall be developed in general conformance with the Conceptual
Plan. The Conceptual Plan is conceptual in nature and may vary based on the final site plan
depending on the final soil studies, RPA lines, road design, lot locations, lot line locations,
amenity locations, VDOT requirements, BMP design and location, pedestrian way design and
location, and other design or engineering reasons. Any substantive changes that do not relate
to the prior sentence may be approved by the Planning Director at the time of plans review, upon
the Director finding that the substantive changes are generally in keeping with the spirit and
Page 33 of 218
30 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
intent of the Conceptual Plan. In the event of any conflict between information shown on the
Conceptual Plan and these Proffered Conditions, these Proffered Conditions shall control. (P)
2. Density. Residential density shall be limited to a maximum of 222 dwelling units. (P)
3. Environmental Engineering. The maximum post-development discharge rate for the 100-
year storm shall be based on the maximum capacity of the existing facilities downstream,
and shall not increase the recorded and /or established 100-year backwater and /or
floodplain. On-Site detention of the post-development 100-year discharge rate to below the
pre-development 100-year discharge rate may be provided to satisfy this requirement. (EE)
4. Utilities.
a. Public water and wastewater shall be used.
b. The owner/developer shall submit a wastewater system hydraulic analysis to verify
downstream capacity of the gravity trunkline to the Utilities Department for review
and approval. The analysis shall be submitted prior to or in conjunction with the first
site or construction plan submittal. Any gravity trunkline capacity related
improvements necessary to support the wastewater demands of this development
shall be the responsibility of the owner/developer and shall be reflected on the site
or construction plan. For clarity, the pump station shall not be included in this
hydraulic analysis.
c. Prior to any tentative subdivision plan or site plan approval, whichever occurs first,
an “Overall Water and Wastewater Plan” (the Plan) for the Property shall be
submitted to and approved by the Utilities Department.
d. Utilities for this development, and phasing thereof, shall conform to the approved
Plan or as otherwise approved by the Utilities Department.
e. The Plan shall include the following components:
i. Any off-site water and/or wastewater improvements (including new lines
and associated appurtenances and/or upgrades to existing lines and
facilities) as needed to provide the volume of water delivery and/or
wastewater conveyance required for the development of the Property.
ii. A sewer line extending offsite from Johnson Creek across Rt 10 into the
development sized to accommodate the development and existing and
future land uses within the sewer shed area, as generally shown on the
Utilities Exhibit.
iii. A 12 inch waterline, from the 12 inch waterline to be constructed by the
County on Point of Rocks Road, through the subdivision to the subdivision’s
western property line, as generally shown on the Utilities Exhibit, or in
another location approved by the Director of Utilities at the time of plans
review for engineering or design reasons. Should the County project not be
in place when this line is constructed, the owner/developer shall provide a
Page 34 of 218
31 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
valve and terminal plug for the County project to connect as close as
possible to the proposed connection.
iv. A public waterline easement up to 20’ in width, on the County’s standard
form, for the portion of waterline along the Property’s frontage on E.
Hundred Road from the subdivision’s western vehicular access onto E.
Hundred Road to the Property’s western property line, or another location
based on the approved location for the 12 inch water line required above.
v. An 8 inch waterline from the existing 12 inch waterline located within the
right of way of Point of Rocks Road to the development’s internal waterline
on the proposed cul-de-sac near the southwestern corner of the
development as generally shown on the Utilities Exhibit, or in another
location approved by the Director of Utilities at the time of plans review for
engineering or design reasons.
vi. A 6 inch waterline from within the project to the existing 6 inch waterline
located within the right of way of Scully Road to the development’s internal
waterline as generally shown on the Utilities Exhibit. If the existing 6 inch
waterline is not located within the right of way of Scully Road, then the
applicant shall not be required to make this connection unless the County
has obtained the necessary right of way or easements to permit this
connection to the existing 6 inch waterline.
f. Following the approval of the Plan, upon request of the County, both access to the
property and easements shall be provided at no cost on standard County
documents, in the location of improvements shown on the Plan, for the construction
of public water and/or wastewater lines independent of the timing of this
development. (U)
5. Chesterfield Department of Transportation.
a. Access. Direct vehicular access shall be limited to two (2) access points from the
Property to East Hundred Road (Route 10) in the general locations shown on the
Conceptual Plan, with the final locations approved by the Transportation
Department in accordance with VDOT requirements. There shall be no direct
vehicular access to Point of Rocks Road.
b. Dedication. In conjunction with recordation of the initial subdivision plat, or within
sixty (60) days after a written request by the County, whichever occurs first, the
following shall be dedicated, free and unrestricted, to and for the benefit of
Chesterfield County measured from the centerline of that part of the roadway
immediately adjacent to the Property:
i. One hundred and ten (110) feet of right-of-way along the south side of East
Hundred Road (Route 10), measured from the centerline of the road; and,
Page 35 of 218
32 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
ii. Forty-five (45) feet of right-of-way along the west side of Point of Rocks
Road.
c. Road Improvements. The following road improvements shall be completed by the
owner/developer as specified below. Any modification to the alignment, design and
length specified below shall be approved by the Transportation Department in
accordance with VDOT requirements. If any of the road improvements identified
below are provided by others, as determined by the Transportation Department, or
not approved by VDOT, then the specific road improvement shall no longer be
required. Unless requested by the owner/developer and approved by the
Transportation Department at the time of plans review, the phasing of each road
improvement shall be provided as specified below.
i. At each vehicular access onto East Hundred Road (Route 10), construction
of additional pavement along the eastbound lane of Route 10 to provide a
separate right turn lane with 200-foot storage and 200-foot taper length into
each vehicular access onto the Property. Each right turn lane shall be
completed in conjunction with each vehicular access to the Property, or
sooner.
ii. If permitted by VDOT, closure of the existing Route 10 median break
located approximately 100 feet west of the Property (“Existing Median
Break”). Improvement shall be completed with construction of New Median
Break as defined below.
iii. If permitted by VDOT, construct a new median break at the westernmost
vehicular access to Route 10, together with a westbound left turn lane and
an eastbound left turn lane, each with 200-foot storage and 200-foot taper
lengths (“New Median Break”). VDOT may approve a full movement
intersection or a directional crossover for this New Median Break. If
permitted by VDOT, this improvement shall be provided in conjunction with
construction of the westernmost vehicular access, unless otherwise
approved by VDOT.
iv. If VDOT does not approve the New Median Break as a full movement
intersection, then the owner/developer shall construct additional pavement
along Route 10 to provide a separate eastbound left turn lane (200-foot
storage and 200-foot taper length) at the Point of Rocks Road intersection
and a separate westbound left turn lane (200-foot storage and 200-foot
taper length) at the Existing Median Break (“WB Left Turn Lane”); provided,
however, that if VDOT approves a directional cross over at the New Median
Break instead of a full movement intersection, then the WB Left Turn Lane
shall not be required. Improvements shall be completed with initial
development.
Page 36 of 218
33 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
v. Dedication to the County or VDOT, as applicable, free and unrestricted, of
any additional right-of-way or easements required for the improvements
identified above.
d. Road Cash Proffers. The Applicant, sub-divider or assignee(s) (“Developer”) shall
pay $9,400.00 for each dwelling unit after the issuance of the 65th certificate of
occupancy for a dwelling on the Property (the “Road Cash Proffer Payment”) to the
County for road improvements within the service district for the Property.
i. Each payment shall be made prior to the issuance of a certificate of
occupancy for a dwelling unit built as part of the development. Should the
County impose impact fees at any time during the life of the Development
that are applicable to the Property, the amount paid in cash proffers shall
be in lieu of or credited toward, but not in addition to, any impact fees, in a
manner determined by the County.
ii. The Developer may elect to pay the Road Cash Proffer Payment or provide
one or more of the Off-Site Road Improvement Options below. The Off-Site
Road Improvement Options determination shall be made by the Developer
prior to any construction plan approval for residential development. If one
or more of the Off-Site Road Improvement Options are provided by the
Developer, then the Road Cash Proffer Payment will be reduced by an
amount approved by CDOT prior to the initial residential plat recordation. If
the Developer elects to complete all three of the Off-Site Road Improvement
Options, then no Road Cash Proffer Payment shall be due to the County.
iii. Off-Site Road Improvement Options: One or more of the following road
improvements may be completed as specified below, as determined by
CDOT in accordance with VDOT requirements. The exact alignment,
design and length of these road improvements shall be approved by CDOT
in accordance with VDOT requirements.
1. Widening/improving the west side of Point of Rocks Road to an
eleven (11) foot wide travel lane, measured from the centerline of
the existing pavement, with an additional five (5) foot wide paved
shoulder, three (3) foot wide unpaved shoulder and mill/overlay the
full width of the road with one and a half (1.5) inch of surface
asphalt, with any modifications approved by the Transportation
Department, for the property frontage. Improvement shall be
completed prior to recordation of a cumulative total of more than 50
lots.
2. Construction of additional pavement along the westbound lanes of
Route 10 at the existing Point of Rocks Road intersection to extend
the existing left turn lane to provide 200-foot storage and 200-foot
Page 37 of 218
34 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
taper lengths, unless modifications approved by the Transportation
Department. Improvement shall be completed prior to recordation
of a cumulative total of more than 50 lots.
3. Construction of additional pavement along the eastbound lanes of
Route 10 at the existing Point of Rocks Road intersection to provide
a right turn lane to provide 200-foot storage and 200-foot taper
lengths, unless modifications approved by the Transportation
Department. Improvement shall be completed prior to recordation
of a cumulative total of more than 50 lots.
iv. At the option of the Developer and approved by CDOT, the Road Cash
Proffer Payments may be reduced for the cost of road improvement(s) not
identified in the “Road Improvements” Proffered Condition, provided by the
Developer, as determined by CDOT. (Budget & T)
6. Police.
a. CBU Lighting. Full cut-off, photocell-activated, minimum 70 CRI-rated LED
luminaires shall illuminate areas within 20 feet of the cluster mailbox units (CBUs)
with a minimum maintained illumination level of 0.5 foot-candles, as measured at
grade, but this requirement may be modified to meet VDOT requirements. (Police)
7. Exterior Facades.
a. Roof materials shall be architectural/dimensional asphalt composition shingle or
better with a minimum 30-year warranty, pre-finished or real copper, or standing
seam metal roof.
b. Acceptable siding materials include brick, stone, masonry, fiber cement siding (such
as HardiePlank, HardieShingle, and HardieTrim), engineered wood siding (such as
LP SmartSide), or high-grade vinyl (a minimum of .044” nominal thickness as
evidenced by manufacturer’s printed literature). Dutch lap, plywood, and metal
siding are not permitted. Any materials may be used for parapets, cornices,
surrounds, trim, architectural decorations, and design elements. (P)
8. Architecture. The architectural appearance of single family detached dwellings constructed
on the Property shall generally conform with (i) the architectural appearance on the
elevations attached hereto as Exhibit B, or (ii) another architectural appearance approved
by the Planning Director at the time of plans review and approval, upon the Director finding
that the new elevations are generally in keeping with the spirit and intent of the elevations in
Exhibit B. The owner of the Property may also ask the Planning Director to approve another
architectural appearance after plans review and approval, upon the Director finding that the
new elevations are generally in keeping with the spirit and intent of the elevations in Exhibit
B. (P)
Page 38 of 218
35 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
9. Variation in Unit Front Elevations. Single family detached dwelling units with the same front
elevation may not be located next to or across the street from another. Variation in the front
elevation may not be achieved by simply mirroring the façade, but may be accomplished by
providing at least three (3) of the architectural changes listed below:
a. Adding masonry elements above the required foundation masonry amount.
b. Changing the location of roof type, roof line, front facing gable(s) and/or dormers.
c. Changing the style of roof type, roof line, front facing gable(s) and/or dormers.
d. Providing varied siding application using horizontal siding, shake siding or board
and batten siding.
e. Providing varied color application.
f. Using a front porch or a covered stoop.
g. Adding projections such as bay/box windows, second floor balconies, or accent
roofs.
h. Adding shutters or trimmed windows.
i. Adding a third design enhancement to the garage door.
j. Any other element of architectural variation as approved by the Director of Planning.
(P)
10. Driveways. All private driveways shall be hardscaped (i.e. constructed from concrete,
asphalt, pavers, or other masonry materials). (P)
11. Front Walks. Front walks shall be provided from the driveway, street or sidewalk to the front
entrance of a dwelling. All front walks shall be a minimum of three (3) feet in width and
hardscaped (i.e. constructed from concrete, pavers, or other masonry materials). (P)
12. Porches and Stoops. Front stoops and porches shall be constructed with continuous
foundation walls, or masonry piers to match the foundation of the home. Handrails and
railings, when required by the building code, shall be finished painted wood, vinyl rails or
metal rail systems with vertical pickets, sawn balusters, or other products of equal quality.
Pickets shall be supported on top and bottom rails that span between columns. (P)
13. Foundation Masonry. There shall be a minimum vertical height of eighteen (18) inches of
brick, brick veneer, stone, stone veneer, or other masonry material approved by the Planning
Director installed above grade for units with slab-on-grade foundations on all front, side, and
rear elevations. All other foundations shall be faced entirely of brick, brick veneer, stone,
stone veneer, cultured stone, and/or other masonry materials; except (i) for units where the
grade drops along the façade foundation this required masonry may step down at eighteen
inch (18”) intervals limited to two step downs, and (ii) for units with a walkout basement siding
may continue to the ground level of a walkout basement (aa) if there is a window or door
that shows the presence of a basement floor or (bb) if there is a first floor deck. Synthetic or
natural stucco foundations may be permitted for facades constructed entirely of stucco. (P)
Page 39 of 218
36 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
14. Heating, Ventilation and Air Conditioning (HVAC) Units and Generators. HVAC units and
generators installed as fixtures shall be screened initially from view of roads by landscaping
or low maintenance material, as approved by the Planning Department. (P)
15. Foundation Plantings. Foundation planting beds shall be required along the entire front
façade of buildings excluding garages, stairs, and walkways, plus any other locations
approved at the time of plans review where planting beds would not be appropriate from a
landscape standard perspective. Foundation planting beds that extend a minimum of one
third (1/3) of the length of the side elevation (as measured from the front corner of the unit)
are also required on building side elevations that are adjacent to public streets. Foundation
planting beds shall contain a minimum of fifty (50) percent evergreen material with one (1)
shrub per three (3) linear feet wide as measured from the unit foundation within a minimum
planting bed depth of four feet (4’), unless modified at the time of plans review. Unit corners
shall be visually softened with vertical accent shrubs (4’-5’ at the time of planting) or small
evergreen trees (6’-8’ at the time of planting). (P)
16. Garage Doors. Any front-loaded garage door shall use an upgraded garage door. An
upgraded garage door is any door that meets one of the following two (2) requirements:
a. A minimum of two (2) enhanced features are provided on the garage door.
Enhanced features shall include windows, raised panels, decorative panels, arches,
ornamental hardware or other architectural features on the exterior that enhance
the entry (i.e. decorative lintels, shed roof overhangs arches, columns, keystones,
eyebrows, etc.) Flat panel garage doors shall be prohibited.
b. The garage door provides an enhanced architectural style that relates to the
architecture of the dwelling the garage serves. Enhanced architectural style shall
mean the use of color, panels and/or windows to reflect an architectural style such
as contemporary, modern, modern farmhouse, mediterranean, colonial, and tudor.
The architectural style may be evidenced by manufacturer printed material. (P)
17. Strategic Amenity Space Types. The areas identified as strategic amenity space shall be
improved with one or more qualifying strategic amenity space types. The specific
improvements shall be identified on the preliminary site plan; provided, however, the
strategic amenity space area shown adjacent to Lots 30 to 38 shall only be improved with
one or more of the following strategic amenity space types: a pavilion, dog park, improved
field, plaza, or community garden. (P)
18. Sidewalks. VDOT standard sidewalks shall be provided along the Property’s frontage on
East Hundred Road and Point of Rocks Road in lieu of a shared use path or other type of
path (as path is defined below) along the Property’s frontage on these roads. (T)
19. Adjustments
Page 40 of 218
37 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
a. Bikeways & Trails Plan. Construction of any shared use path, trail, or similar bikeway
improvement (“path”), shall not be required along East Hundred Road or Point of
Rocks Road. In lieu of construction of a path, the applicant’s dedication proffer
above includes an extra ten (10) feet of right-of-way along East Hundred Road. This
adjustment does not remove the owner/developer’s obligation to install sidewalks
along East Hundred Road and Point of Rocks Road.
b. Public Utility Easements in Buffers. Public utility easements granted to Chesterfield
County may be located in any manner, including, without limitation, a parallel
manner, within the portions of the required buffers along East Hundred Road and
Point of Rocks Road, as such portions of the required buffers are shown on the
Utilities Exhibit provided by the Utilities Department and where existing public utility
easements exist. Where a public easement is co-located with a buffer, the planting
standard shall be increased to 4 times Perimeter Landscape B and section 19.2-
41.A.10 shall be followed. (P)
20. Privacy Fence. A privacy fence approximately six feet (6’) tall shall be provided along the
shared property line where noted on the Conceptual Plan, unless a different location is
approved at the time of plans review and approval. The privacy fence shall be constructed
as a wood or vinyl board on board fence. (P)
21. GPIN 827-641-3271. Open space, a minimum of ten (10) feet deep, shall be provided along
the shared property line with GPIN 827-641-3271, except where a road buffer is required.
This open space shall be made part of the common area to be owned by the homeowner’s
association for the project. (P)
[Staff Note: See location of this parcel reference on the Current Zoning Map]
22. GPIN 826-642-8234. So long as GPIN 826-642-8234 is zoned to the Agricultural (A) District,
a twenty-five (25) foot wide perimeter landscape buffer shall be required around the
perimeter of GPIN 826-642-8234. (P)
[Staff Note: See location of this parcel reference on the Current Zoning Map]
23. Lighting. Lighting requirements for sidewalks and driveways shall be met with a post light
placed in the front yard with an additional carriage light near the garage door. (P)
24. Garage Depth. If the garage projects more than five (5) feet from the main dwelling line of
the home, then a window shall be included in the garage sidewall adjacent to the lead walk
or the front door. (P)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Page 41 of 218
38 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
26SN2139: In Bermuda Magisterial District, Dominion Sycamore Springs Switching
Station is a request to rezone from Suburban Community (SC) to Suburban Community
(SC) with adjustments to ordinance requirements for development standards plus
conditional use to permit a utility substation and amendment of zoning district map on 30
acres fronting the eastern terminus of Sulphur Springs Terrace and lying approximately 300
feet off the east side of Bermuda Orchard Lane, 425 feet north of Sycamore Springs Drive,
known as 14351 Bermuda Orchard Lane. The Comprehensive Plan suggests the property
is appropriate for Residential Neighborhood 4 use (4.0 units per acre or less). Tax ID 817-
644-4395.
Mr. Rich Saunders presented the case.
There was opportunity for questions by the Commissioners for Mr. Saunders.
There were no questions.
Mr. Brian Jackson came forward on behalf of the applicant and gave a brief presentation on
the request.
In response to a question from Mr. Sloan, Mr. Jackson confirmed there are no plans for
transformers now or in the future.
Ms. Hardin opened the public hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. David Merritt and Ms. Marie Bradley came forward and expressed concerns regarding
the location of the project, citing noise, wildlife, and wetlands.
Mr. Michael McDonough came forward and made comments in support of the request,
including the location, noting its proximity to the railroad.
Mr. Jerry Turner came forward and stated this is the best location for this project and the
company is doing good by accodomating what the County is allowing to happen.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Mr. Jackson came forward in rebuttal. He addressed the concerns by providing the plans
the developer has in place to mitigate any negative impacts.
Page 42 of 218
39 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Mr. Sloan led the discussion. He reminded citizens to get involved with the site-plan process
regarding screening. However, the zoning is appropriate and he supports the case.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 26SN2139 subject to the Proffered Conditions.
PROFFERED CONDITIONS (7/9/2026)
The property owners and applicant in this rezoning case, pursuant to Section 15.2-2298 of
the Code of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County
(the “Zoning Ordinance”), for themselves and their successors or assigns, proffer that the
property under consideration (the “Property”) will be developed according to the following
proffers if, and only if, the rezoning request submitted herewith is granted with only those
conditions agreed to by the owners and applicant. In the event this request is denied or
approved with conditions not agreed to by the owners and applicant, the proffers shall
immediately be null and void and of no further force or effect.
These Proffered Conditions include two (2) exhibits attached hereto:
Exhibit A: “Dominion Sycamore Springs Switching Station: Concept Site Plan for Case
#26SN2139” prepared by Kimley-Horn, last revised July 8, 2026 (“Concept Plan”).
Exhibit B: “Tree Preservation Plan” prepared by Timmons Group last revised July 8, 2026
(“Tree Preservation Plan”).
The following are the proffered conditions for the request:
1. Concept Plan. The Property shall be designed as generally depicted on the Concept Plan;
however, the exact dimensions of the switching station, stormwater management features,
and limits of clearing may be modified provided that the general intent of the Concept Plan
is maintained. (P)
2. Tree Preservation. To protect existing vegetation, no clearing, except for the removal of dead
or diseased trees, shall take place in the location identified as "Tree Preservation Area" on
the Tree Preservation Plan. (P)
3. Vehicular Access.
a. Construction Access: Access to the Property shall be to/from Bermuda Orchard Lane.
In the event that the Bermuda Orchard Lane access is inaccessible due to environmental
constraint(s), operational safety or permitting, access to the Property shall be provided
to/from Sulphur Springs Terrace.
Page 43 of 218
40 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
b. Post Construction Access: Access to the Property shall be to/from Sulphur Springs
Terrace. (T)
4. Traffic Management Plan. Prior to site plan approval, the Property owner shall submit a traffic
management plan ("TMP") for maintenance of Bermuda Orchard Lane, Sulphur Springs
Terrace, and Sycamore Springs Drive during and upon completion of construction of
improvements on the Property. The TMP plan shall include measures to use commercially
reasonable efforts to keep dirt and debris from accumulating on these streets and addressing
any road repairs resulting from construction traffic associated with improvements on the
Property. (T)
5. Signage. Metal ‘No Trespassing’ signage shall be installed on the exterior of each vehicle
and pedestrian fence gate and at 30’ intervals along the security fence perimeter. (Police)
6. Construction Times. Any construction activity that results in sound clearly audible at the
Property lines shall be limited to Monday through Saturday, 7:00 a.m. to 7:00 p.m. Except in
the event of an emergency, there shall be no activity that results in sound clearly audible at
the Property lines on Sundays or national holidays. (P)
7. Noise Measurement Protocol. The Property owner shall submit a sound study (or other
documentation satisfactory to the Director of Planning) to demonstrate that noise levels from
the switching station will not exceed 55 dBA at any adjacent property line except for property
lines adjacent to a railroad right-of-way within 90 days of station energization. If noise levels
exceed 55 dBA at any point on the exterior of adjacent property lines except for any property
lines adjacent to a railroad right-of-way, the Property owner/operator shall submit a plan to
mitigate excess noise. (P)
The following are the proposed adjustments to the Zoning Ordinance:
8. Security Fencing. The switching station shall be enclosed by security fencing between fifteen
(15) and thirty (30) feet in height (may be variable in height), constructed of high security
steel fabric panels, and shall not include barbed wire. The fencing location shall be as
generally shown on the Concept Plan. The fencing shall have a similar appearance to the
images entitled "Security Fence Example Photos" on the Concept Plan. (P)
9. Gravel Access Drives. The surface treatment for access drives shall be either asphalt or
gravel. Any gravel drive shall be well-graded crushed run aggregate (21B or equivalent) in
lieu of pavement. All drives shall be designed to meet minimum access requirements for
emergency equipment. (P and F)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Page 44 of 218
41 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
22SN0073 (Deferred from 06/16/2026): In Matoaca Magisterial District, Big E Ranch
Rezoning is a request to rezone from Agricultural (A) to Rural Community (RC) and
amendment of zoning district map known as 11301 Trents Bridge Road. The 548.88 acre
property is proposed for a maximum development of 65 dwelling units. The Comprehensive
Plan suggests the property is appropriate for Residential Agricultural use (0.5 units per acre
or less). Tax IDs 746-616-5488; 746-619-5970; and 749-621-3742.
Mr. Rich Saunders presented the case. He reported one (1) comment from the portal
regarding road improvements.
There was opportunity for questions by the Commissioners for Mr. Saunders.
There were no questions.
Mr. Jeff Geiger came forward on behalf of the applicant and gave a brief presentation on the
request.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. Matt Igland came forward representing an adjacent neighborhood with concerns
regarding traffic and the safety of the residents who walk along Trent’s Bridge and Exter Mill
Roads.
Mr. Charles York came forward with concerns regarding traffic, historical structures, and
density.
Mr. Jerry Turner came forward in support of the request and stated five (5) acre lots should
be the standard for the whole County.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Mr. Geiger came forward in rebuttal. He addressed the concerns by providing the plans the
developer has in place to mitigate any negative impacts.
Mr. Sloan led the discussion. He appreciated the comments received from the residents,
and stated he is in support of the case.
On motion of Mr. Sloan, seconded by Ms. Richardson, the Commission resolved to
recommend approval of Case 22SN0073 subject to the Proffered Conditions.
Page 45 of 218
42 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
PROFFERED CONDITIONS (7/8/2026)
The property owner (“Applicant’) pursuant to Section 15.2-2298 of the Code of Virginia (1950
as amended) and the Zoning Ordinance of Chesterfield County, for itself and its successors
or assigns, proffers that the use of the property under consideration in this case (the
“Property”) will be according to the following conditions if, and only if, the request submitted
herewith is granted with only those conditions agreed to by the Applicant. In the event this
request is denied or approved with conditions not agreed to by the Applicant, the proffer
conditions shall immediately be null and void and of no further force or effect.
These Proffered Conditions include one (1) exhibit attached hereto:
Exhibit A: “Big E Ranch, LLC Conceptual Layout” prepared by Townes Site Engineering,
dated February 25, 2026 (“Concept Plan”).
1. Conceptual Plan. The Property shall be developed in general conformance with the
Conceptual Plan. The Conceptual Plan is conceptual in nature and may vary based
on the final approved plats and plans, as applicable, depending on the final soil
studies, RPA lines, road design, lot locations, lot line locations, Virginia Department
of Transportation (“VDOT”) and County Transportation Department (“CDOT”)
requirements, BMP design and location, and other design or engineering reasons.
Any substantive changes that do not relate to the prior sentences may be submitted
to the Planning Director for approval at the time of plat or plans review. The Director
shall evaluate the change(s) to determine that change(s) are consistent with the
spirit and intent of large lot subdivision shown on the Conceptual Plan. In the event
of any conflict between information shown on the Conceptual Plan and these
Proffered Conditions, these Proffered Conditions shall control. (P)
2. Density. Maximum density shall be restricted to 65 residential dwelling lots. (P)
3. Road Improvements.
a. Prior to the issuance of the sixth (6th) building permit for a dwelling on the
Property, the following road improvements shall be completed by the owner of
the Property or by others. Any modification to the alignment, design and length
shown on the Conceptual Layout and/or specified below shall be approved by
the Chesterfield County Transportation Department. If any of the road
improvements identified below are provided by others, as determined by the
Transportation Department, then the specific road improvement shall no longer
be required. The timing for the provision of these improvements may be
adjusted by a phasing plan approved by the Transportation Department at the
time of plans review.
Page 46 of 218
43 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
i. Widen/improve Exter Mill Road south of its intersection with Trents
Bridge Road to provide a minimum pavement width of 22’.
ii. Dedication to the County or VDOT, free and unrestricted, of any
additional right-of-way and/or easements required for the improvement
identified above.
b. Prior to the issuance of the tenth (10th) building permit for a dwelling on the
Property, the following road improvement shall be completed by the owner of
the Property or by others. Any modification to the alignment, design and length
shown on the Conceptual Layout and/or specified below shall be approved by
the Chesterfield County Transportation Department. If any of the road
improvements identified below are provided by others, as determined by the
Transportation Department, then the specific road improvement shall no longer
be required.
i. Widen/improve the Property’s frontage along Trents Bridge Road to an
eleven foot (11’) wide travel lane, measured from the centerline of the
existing pavement, with an additional five foot (5’) paved shoulder plus
a three foot (3’) unpaved shoulder and overlaying the full width of the
road with a minimum of one and one-half inches (1.5”) of surface
asphalt, with any modifications approved by the Transportation
Department.
ii. Dedication to the County or VDOT, free and unrestricted, of any
additional right-of-way and/or easements required for the improvement
identified above.
c. The road labeled 20’ Paved Emergency Vehicle Access shall be constructed as
a private road, 20’ in width and designed to support the load of fire apparatus
(75k lbs) with a surface for all-weather driving capabilities. This road shall
remain unobstructed. The homeowner’s association shall be responsible for the
maintenance of this private road and shall restrict the use of this road to prevent
parking and storage on the road. (T & F)
4. Exterior Facades and Roofs.
a. Roof materials shall be 30 year (minimum) architectural/dimensional asphalt
composition shingle or standing seam metal. Material used on flat roofs shall
have a minimum 30 year warranty.
b. Acceptable siding materials include brick, stone, masonry, fiber cement siding
(such as HardiePlank, HardieShingle, and HardieTrim), engineered wood siding
(such as LP SmartSide), or high-grade vinyl (a minimum of .044” nominal
thickness as evidenced by manufacturer’s printed literature). Dutch lap,
Page 47 of 218
44 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
plywood, and metal siding are not permitted. Other materials may be used for
parapets, cornices, surrounds, trim, architectural decorations, and design
elements. (P)
5. Foundation Treatment. There shall be a minimum vertical height of eighteen (18)
inches of brick, brick veneer, stone, stone veneer, or other masonry material
approved by the Planning Director installed above grade for units with slab-on-grade
foundations on all front, side, and rear elevations. All other foundations shall be
faced entirely of brick, brick veneer, stone, stone veneer, cultured stone, and/or
other masonry materials; except (i) for units where the grade drops along the façade
foundation this required masonry may step down at eighteen inch (18”) intervals
limited to two (2) step downs, and (ii) for units with a walkout basement siding may
continue to the ground level of a walkout basement (aa) if there is a window or door
that shows the presence of a basement floor or (bb) if there is a first floor deck.
Synthetic or natural stucco foundations may be permitted for facades constructed
entirely of stucco. (P)
6. Architecture. Architectural styles for dwellings shall be interpretations of traditional
and modern Richmond architecture, using forms and elements compatible (but not
limited to) Georgian, Classical Revival, Colonial, Greek Revival, Queen Anne,
Craftsman, Ranch, split-level, Salt Box, Cape, mid-century Modern, Modern, and
Traditional styles. (P)
7. Variation in Unit Front Elevations. Single family detached dwelling units with the
same front elevation may not be located next to or across the street from another.
Variation in the front elevation may not be achieved by simply mirroring the façade,
but may be accomplished by providing at least two (2) of the architectural changes
listed below:
a. Adding masonry elements above the required foundation masonry amount.
b. Changing the location of roof type, roof line, front facing gable(s) and/or
dormers.
c. Changing the style of roof type, roof line, front facing gable(s) and/or dormers.
d. Providing varied siding application using horizontal siding, shake siding or board
and batten siding.
e. Providing varied color application.
f. Using a front porch or a covered stoop.
g. Adding projections such as bay/box windows, second floor balconies, or accent
roofs.
Page 48 of 218
45 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
h. Adding shutters.
i. Adding trimmed windows.
j. Adding a third design enhancement to the garage door.
k. Any other element of architectural variation as approved by the Director of
Planning. (P)
8. Porches and Stoops. Front stoops and porches shall be constructed with continuous
foundation walls, or masonry piers to match the foundation of the home. Front
porches shall be a minimum of five (5) feet deep. Handrails and railings, when
required by the building code, shall be finished painted wood, vinyl rails, metal rail
systems or another rail system approved by the Planning Director at the time of
plans review. Where used, pickets shall be supported on top and bottom rails that
span between columns. (P)
9. Foundation Plantings. Foundation planting beds shall be required along the entire
front façade of buildings excluding garages, stairs and walkways accessing porches
and patios. Foundation planting beds that extend a minimum of one third (1/3) of
the length of the side elevation (as measured from the front corner of the unit) are
also required on building side elevations that are adjacent to public streets.
Foundation planting beds shall contain a minimum of fifty (50) percent evergreen
material with one (1) shrub per three (3) linear feet wide as measured from the unit
foundation within a minimum planting bed depth of four feet (4’), unless modified at
the time of plans review. Unit corners shall be visually softened with vertical accent
shrubs (4’-5’ at the time of planting) or small evergreen trees (6’-8’ at the time of
planting). (P)
10. Front Walks. Front walks shall be provided from the driveway or sidewalk to the front
entrance of a dwelling. All front walks shall be a minimum of three (3) feet in width
and hardscaped (i.e. concrete, pavers or other masonry materials). (P)
11. Driveways. All private driveways shall be hardscaped (i.e. concrete, asphalt or
pavers). (P)
12. Heating, Ventilation and Air Conditioning (HVAC) Units and Generators. HVAC units
and generators installed as fixtures shall be screened initially from view of roads by
landscaping or low maintenance material, as approved by the Planning Department.
(P)
13. Garage Doors. Any front-loaded garage door, located on the front elevation of the
home and visible from a public street, shall use an upgraded garage door. An
upgraded garage door is any door that meets one of the following two (2)
requirements:
Page 49 of 218
46 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
a. A minimum of three (3) enhanced features are provided on the garage door.
Enhanced features shall include windows, raised panels, decorative panels,
arches, ornamental hardware or other architectural features on the exterior that
enhance the entry (i.e. decorative lintels, shed roof overhangs arches, columns,
keystones, eyebrows, etc.). Flat panel garage doors shall be prohibited.
b. The garage door provides an enhanced architectural style that relates to the
architecture of the dwelling the garage serves. Enhanced architectural style
shall mean the use of color, panels and/or windows to reflect an architectural
style such as contemporary, modern, modern farmhouse, mediterranean,
colonial, and tudor. The architectural style may be evidenced by manufacturer
printed material. (P)
14. Use Permissions. The following uses shall not be permitted on the Property:
a. Manufactured Home (on a single lot).
b. Manufactured Home, Temporary.
c. Manufactured Home Park. (P)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
25SN1158 (Deferred from 06/16/2026): In the Matoaca Magisterial District, McDonough
Equipment Wholesale & Storage is a request for conditional use to permit a home
occupation (equipment wholesale and storage) and amendment of zoning district map in the
Agricultural (A) District on 50 acres known as 11671 Adventure Hill Lane. The
Comprehensive Plan suggests the property is appropriate for Rural Residential / Agricultural
use (0.2 units per acre or less). Tax IDs 718-650-4408 and 719-648-6227.
Ms. Betsy Hatch presented the case. Ms. Hatch stated she received two (2) letters from the
comment portal and two (2) additional letters received during the meeting and provided them
to the Commissioners.
There was opportunity for questions by the Commissioners for Ms. Hatch.
There were no questions.
The applicant, Mr. Michael McDonough, came forward and explained his business is only
for his family and he wishes to have no negative impact on the community. He stated he has
received a lot of support from neighbors as he allows the community to use his property for
Page 50 of 218
47 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
various reasons such as softball games and use of his shooting range. He thanked staff for
their help with his request.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. Jerry Turner came forward in support of the request.
Ms. Heidi McDonough, the applicant’s wife, came forward and stated the equipment that
comes in and out is no larger than a garbage truck. She stated they were not aware their
business was in violation; however, it has no negative impacts on the community and asked
the Commissioners to send a recommendation of approval to the Board of Supervisors.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Mr. Sloan led the discussion. He stated he received a great amount of support from
surrounding neighbors and gladly supports the request.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1158 subject to the Conditions.
CONDITIONS
1. Use. This conditional use approval shall be for the operation of a home occupation (heavy
equipment wholesale and storage business). (P)
2. Non-Transferable Ownership. This conditional use approval shall be granted exclusively to
Michael McDonough and Heidi McDonough and shall not be transferrable with the land. (P)
3. Time Limitation. This conditional use approval shall be granted for a period not to exceed
three (3) years from the date of approval. (P)
4. Hours of Operation. Hours and days of operation shall be limited to Monday through Friday
from 7 a.m. to 6 p.m. There shall be no Saturday or Sunday operations of this use. (P)
5. Equipment Storage & Sales.
i. No more than fifteen (15) pieces of equipment for sale shall be stored on the
property and no more than fifteen (15) pieces of equipment shall be sold on a
monthly basis.
ii. For sale equipment shall be stored within the designated storage area as shown on
Exhibit A and shall be clearly delineated from personal equipment. (P)
Page 51 of 218
48 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
6. Setbacks. Storage of construction equipment on the property shall be set back a minimum
of thirty-five (35) feet from all property lines as shown on Exhibit A. The setback area shall
be maintained in its vegetated state. (P)
7. Employees and Clients. No employees shall be permitted to work on the premises other
than family member employees that live on the premises. No more than 2 clients shall be
permitted on the property at a time. (P)
8. Signage. There shall be no signage identifying this use. (P)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Ms. Hardin called a brief recess at 8:33 p.m. The Commissioners reconvened at 8:45 p.m.
25SN1208: In Matoaca Magisterial District, Spring Run Road Rezoning is a request to
rezone from Agricultural (A) to Semi-Urban Neighborhood (SU) plus a waiver to connectivity
and conditional use to permit a telecommunications tower and amendment of zoning district
on property fronting approximately 1,150 feet on the north side of Spring Run Road, 450 feet
west of Pasture Hill Road, known as 13200 Spring Run Road. The 102.4 acre property is
proposed for a maximum development of 199 dwelling units. The Comprehensive Plan
suggests the property is appropriate for Residential Neighborhood 4 use (4.0 units per acre
or less). Tax ID 733-664-0529.
Ms. Betsy Hatch presented the case. She reported receiving three (3) comments in
opposition.
There was opportunity for questions by the Commissioners for Ms. Hatch.
In response to a question from Mr. Sloan, Ms. Hatch stated that if the tower does not go in,
the space would be left as open or amenity space.
Ms. Anne Miller came forward on behalf of the applicant and gave a brief presentation on
the request.
There were no questions for Ms. Miller.
Ms. Hardin opened the Public Hearing.
Page 52 of 218
49 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. Charles Downs, Ms. Melanie Downs, Mr. Jerry Turner, Ms. Jenny Castle, Ms. Jenn
Groome, and Ms. Laura Saunders all came forward in opposition. Collectively, their
concerns were traffic, schools, density, wildlife, stormwater runoff, and infrastructure.
Mr. Ken Tarrant, representing approximately thirty (30) of his neighbors, came forward in
support of the request. While he understands the opposition, he stated if change had to
happen, this is the way to do it.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Ms. Anne Miller came forward in rebuttal. She addressed the concerns by providing the
plans the developer has in place to mitigate any negative impacts.
Mr. Sloan led the discussion and offered reasons for his support. Mr. Petroski also made
supporting comments. Both agreed that the developer has a reputation for responsibly
handling environmental features such as tree preservation. Ultimately, Mr. Sloan concluded
that the applicant has made substantial efforts to meet the County’s expectations and he
would be sending a recommendation of approval to the Board of Supervisors.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1208 Request 1 subject to the Proffered Conditions.
On motion of Mr. Sloan, seconded by Mr. Petroski, the Commission resolved to recommend
approval of Case 25SN1208 Request 2 subject to the Proffered Conditions.
PROFFERED CONDITIONS (7/14/2026)
1. Conceptual Plan. Development of the Property shall generally conform to the “Spring Run
Concept Plan” (the “Conceptual Plan”), last revised June 30, 2026, with respect to general
layout of roads, lots, and amenity space. The layout is conceptual in nature and is subject
to modification based on the approval of subdivision plans depending on final engineering
and environmental studies or as otherwise approved by the Planning Director, or assignee,
at the time of plans review. In the event of any conflict between information shown on the
Conceptual Plan and these Proffered Conditions, these Proffered Conditions shall control.
(P)
2. Utilities. The public water and wastewater systems shall be used.
Page 53 of 218
50 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
a. The applicant shall submit an Overall Water and Wastewater Plan in conjunction
with the Preliminary Plat. This plan shall be reviewed and approved prior to the
submission of any construction plans.
b. The applicant shall submit a wastewater hydraulic analysis to the Utilities
Department for review and approval in conjunction with the first construction plan
submittal. The Developer shall be responsible for any capacity-related
improvements identified as necessary to support the demands of the project, and
such improvements shall be shown on the construction plans.
c. Unless otherwise approved by the Utilities Department during plans review, the
applicant shall provide an upsized waterline connection as generally shown on the
Utilities Exhibit dated 07/09/26. The exact alignment and size of the waterline shall
be determined by the Utilities Department during the development of the Overall
Water and Sewer Plan. A 16-foot permanent easement shall be provided for any
portions of the waterline located outside of public rights-of-way.
d. Unless otherwise approved by the Utilities Department during plans review, the
applicant shall provide an interconnecting waterline to the existing 8-inch waterline
on Clover Way as generally shown on the Utilities Exhibit dated 07/09/26.
e. Unless otherwise approved by the Utilities Department during plans review, the
applicant shall provide extensions of wastewater lines for future service with 16-foot
permanent easements as required in the locations as generally shown on the
Utilities Exhibit dated 07/09/26. (U)
3. Density. The maximum density shall not exceed 199 units. (P)
4. Access. Direct vehicular access from the Property to Spring Run Road shall be limited to
two (2) accesses with the exact location approved by the Transportation Department. (T)
5. Road Improvements. In conjunction with initial development unless otherwise noted below,
the following road improvements shall be completed, as determined by the Transportation
Department. The Transportation Department shall approve the exact design, length, or other
modifications of the improvements.
a. Widening/improving the north side of Spring Run Road to a twelve (12) foot wide
travel lane, measured from the centerline of the existing pavement, with an
additional four (4) foot wide paved shoulder plus a four (4) foot wide unpaved
shoulder and overlaying the full width of the road with one and a half (1.5) inch of
compacted bituminous asphalt concrete, with any modifications approved by the
Transportation Department, for the entire property frontage.
Page 54 of 218
51 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
b. At the proposed full-vehicle access: construction of additional pavement along
Spring Run Road at the approved access to provide right and left turn lanes.
Improvements shall be provided in conjunction with the vehicular access.
c. At the restricted vehicular access: Construction of a raised median and/or other
traffic device(s), as approved by the Transportation Department and VDOT, to limit
the vehicular access to right-in/right-out and construction of additional pavement
along Spring Run Road to provide a separate right turn lane. Improvement shall be
provided in conjunction with the vehicular access.
d. Construction of a three (3) lane typical section (2 outbound lanes/1 inbound lane)
along the proposed full vehicular public road access to Spring Run Road.
e. Dedication to Chesterfield County, free and unrestricted, of any additional right of
way (or easements) required for the improvements identified above. (T)
6. Dedication. In conjunction with recordation of the initial subdivision plat, prior to any final site
plan approval, or within sixty (60) days from a written request by the Transportation
Department, whichever occurs first, fifty(50) feet of right-of-way along the north side of
Spring Run Road, measured from the centerline of the part of the roadway immediately
adjacent to the Property, shall be dedicated, free and unrestricted, to and for the benefit of
Chesterfield County. (T)
7. Road Cash Proffers.
a. The applicant, sub-divider, or assignee(s) shall pay $9,400 for each dwelling unit to
Chesterfield County for road improvements within the service district for the property
(the “Cash Proffer Payments”).
b. Each payment shall be made prior to the issuance of a certificate of occupancy for
a dwelling unit unless state law modifies the timing of the payment. Should
Chesterfield County impose impact fees at any time during the life of the
development that are applicable to the property, the amount paid in cash proffers
shall be in lieu of or credited toward, but not in addition to any impact fees, in a
manner determined by the county.
c. At the option of the Transportation Department, Cash Proffer Payments may be
reduced for the cost of transportation improvements, other than those improvements
identified in the Road Improvements Proffered Condition, provided by the applicant,
sub-divider, or assignee(s), as determined by the Transportation Department.
(Budget)
Page 55 of 218
52 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
8. Internal Public Road Design (“Roads”). At time of plans review, roads shall be designed or
layout revised to accommodate traffic calming design and/or features, such as traffic circles,
intersection bump-outs, or other design elements/alignments, as approved by the
Transportation Department and VDOT. (T)
9. Environmental Engineering.
a. The maximum post-development discharge rate for the 100-year storm shall be
based on the maximum capacity of the existing facilities downstream and shall not
increase the recorded and /or established 100-year backwater and /or floodplain.
On-Site detention of the post-development 100-year discharge rate to below the
pre-development 100-year discharge rate may be provided to satisfy this
requirement.
b. The existing dam, DCR #041079 Geara Woods Dam, located on the Property shall
be modified to meet all applicable standards and requirements of the Virginia
Department of Conservation and Recreation (DCR) Dam Safety Regulations. The
dam shall remain under the ownership and maintenance of the Developer until
completion of the required modifications and receipt of the Final Certification from
DCR, at which time ownership and maintenance shall be transferred to and
assumed by the Homeowners’ Association (HOA). (EE)
Subdivision Design Elements
10. Driveways. All private driveways serving residential units shall be brushed concrete,
stamped concrete, exposed aggregate concrete, decorative pavers, or asphalt. (P)
11. Front Walks. A minimum of three (3) foot wide concrete (brushed, stamped or exposed
aggregate) front walks shall be provided to each dwelling unit to connect drives, sidewalks,
and/or streets. (P)
12. Front Foundation Planting Beds. Foundation planting is required along the entire front and
corner side façade(s) of all dwelling units. Foundation planting beds shall be a minimum of
four (4) feet wide from the unit foundation. Planting beds shall include medium shrubs
spaced a maximum of four (4) feet apart. The plant materials used should visually soften the
unit corners and complement the architecture of the home at their mature sizes. (P)
13. Architecture. Residential dwelling units shall reflect sound architectural design principles as
shown in the “Spring Run Conceptual Elevations” (Exhibit B). The intent is to create a
cohesive, attractive community featuring a variety of architectural styles, such as Classical,
Georgian, Colonial Revival, Craftsman, American Arts & Crafts, Victorian, and European
Romantic. Construction of residential units shall be in general conformance with the
architectural appearance shown on the illustrative elevations or another architectural
Page 56 of 218
53 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
appearance approved by the Planning Director at the time of plans review. Subsequent to
plans approval, the owner may also request approval of another architectural appearance
by the Planning Director. The illustrative elevations are conceptual in nature and may vary
in detail at the time of plans review. (P)
14. Exterior Facades.
a. Acceptable siding materials include brick, stone, masonry, cementitious siding (such
as HardiPlank, HardieShingle, and HardieTrim), or engineered wood siding (such
as LP SmartSiding), premium quality vinyl siding with a minimum thickness of 0.044
inches or other comparable material as approved by the Planning Department at
time of plans review. Plywood and metal siding are not permitted. Other materials
may be used for trim, architectural decorations, or design elements provided they
blend with the architectural style of the dwelling unit. Where a dwelling borders more
than one street, all street-facing facades shall be finished in the same materials.
b. If the dwelling is constructed on a slab, brick, brick veneer, stone, stone veneer, or
other masonry material shall be employed around the base of the dwelling a
minimum of eighteen (18) inches above grade so as to give the appearance of a
foundation. If not constructed on slab, all exposed portions of the foundation of each
dwelling shall be faced with brick, brick veneer, stone, stone veneer, or other
masonry material.
c. Stepping the siding down below the first floor shall only be permitted in
circumstances of unique topographical conditions. For dwelling units stepping the
siding down below the first floor shall be permitted on the side and rear elevations
that do not front on a street, with a maximum of two (2) steps permitted on any
elevation. A minimum of eighteen (18) inches of exposed brick or stone shall be
required, unless a lesser amount is approved by the Planning Department at the
time of plan review due to unique design circumstances.
d. Roof materials on pitched roofs shall be thirty (30) year minimum architectural
dimensional asphalt composition shingle or standing seam metal. In the event that
flat roofs are proposed, the roofing materials shall be of a similar quality and
durability to those specified above. (P)
15. Porches & Stoops. Front stoops and porches shall be constructed with continuous
foundation walls or masonry piers to match the foundation of the home. (P)
16. Garages. Front loaded, and corner side loaded garages shall use an upgraded garage door.
An upgraded garage door is any door with a minimum of three (3) enhanced features.
Enhanced features may include windows, raised panels, decorative panels, arches,
ornamental hardware, or other architectural features on the exterior that enhance the entry
Page 57 of 218
54 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
(i.e., decorative lintels, shed roof overhangs, arches, columns, keystones, eyebrows, etc.).
Flat panel garage doors are prohibited. (P)
17. Heating Ventilation and Air Conditioning (HVAC) Units and Whole House Generators. Units
shall initially be screened from view of roads by landscaping or low maintenance material,
as approved by the Planning Department. (P)
18. Amenity Space. Amenity space shall be provided in accordance with the requirements of the
Zoning Ordinance. In addition to the amenities described below, the Applicant may provide
other amenities from the categories outlined in the Zoning Ordinance to satisfy the required
amount and standards for amenity space.
a. Pathways shall be provided around the existing lake, generally consistent with the
alignment depicted on the Conceptual Plan. The exact design, materials, and
placement of the pathways shall be subject to review and approval during plans
review, including permitting by appropriate agencies. If for any reason a permit
cannot be obtained for certain locations, pathways shall not be required in those
locations.
b. A dock or pier providing access to the existing lake shall be provided in the general
location shown on the Conceptual Plan subject to permitting by appropriate
agencies. The exact design, materials, and placement of such structure shall be
subject to review and approval during plans review. If for any reason a permit cannot
be obtained, the dock or pier shall not be required.
c. A fire pit and gazebo shall be provided. The exact design, materials, and placement
of such structures shall be subject to review and approval during plans review. If the
dock or pier as described above is not permitted, the fire pit and gazebo shall be
provided in that general location.
d. A covered structure, such as small pavilion, shall be provided in the general location
shown on the Conceptual Plan. The exact design, materials, and placement of such
structure shall be subject to review and approval during plans review. (P)
19. Phasing of Amenity Space. Amenity space and strategic amenity space shall be developed
concurrently with the phase of development in which such amenity space is located. The
exact design, location, and size of all amenity spaces and strategic amenity spaces shall be
subject to review and approval during plans review. (P)
20. Buffer.
a. A twenty-five (25) foot buffer shall be provided along the northern and eastern
property lines in accordance with the requirements of the Zoning Ordinance. In
Page 58 of 218
55 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
addition to the required buffer treatment, a privacy fence with a minimum height of
six (6) feet, constructed of vinyl or pressure-treated wood, shall be installed along
the northern and eastern property lines adjacent to the buffer. This fence shall be
maintained by the Homeowners Association.
b. The minimum lot size for the lots adjoining the buffer along the northern and eastern
property boundaries shall be 11,000 square feet. All such lots shall comply with the
applicable lot and building standards of the Base Option within the Semi-Urban
Neighborhood (SU) District for Single-Family Lots. (P)
21. Elevation Variation. The same dwelling unit elevations shall not be located adjacent to or
directly across from each other along the same road. This requirement does not apply to
units on different streets backing up to each other. Variation in the front elevation shall not
be achieved by simply mirroring the façade but may be accomplished by providing at least
three (3) of the following architectural changes.
a. Adding or removing a porch or covered entry or increasing or decreasing the length
of the porch or entry.
b. Adding masonry on the front façade elevation of the first floor.
c. Varying the location and/or style of roof type, roof line, front facing gable(s) and/or
dormers.
d. Providing varied siding application using horizontal siding, shake siding, and/or
board and batten siding.
e. Adding projections such as bay windows, second floor balconies, and accent roofs.
f. Alternating the location of a garage, if provided.
g. Providing a different architectural style.
h. Any other element of architectural variation as approved by the Director of Planning.
(P)
22. Telecommunications Tower. The following conditions shall apply to a telecommunications
tower if constructed on the Property:
a. Reservation of Tower Area. The Applicant shall reserve and set aside an area on
the Property (the “Tower Area”) for the potential future construction of a wireless
Telecommunication Tower (the “Tower”). If a Tower is provided, the Tower Area
shall be located in either Tower Area ‘A’ or Tower Area ‘B’, as generally shown on
the Telecommunication Tower Exhibit, dated June 30, 2026. The precise placement
of the Tower within the selected Tower Area shall be determined during plans
review. The Tower Areas shall not be conveyed to the Homeowners Association
until a tower is constructed or the Tower Areas have been terminated (in accordance
with item b below).
b. Termination of Reservation of Tower Area. The obligation to reserve the Tower Area
shall terminate upon the earlier of:
Page 59 of 218
56 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
i. Eight (8) years from the date of approval of this rezoning case if no Tower
has been constructed within the Tower Area by that date; or
ii. A written determination by Chesterfield County, or its designated agent,
says that the Tower Area is no longer needed for a Tower.
Upon termination, all obligations relating to the reservation of the Tower Area shall
cease and be of no further force and effect, and the Applicant and its successors
and assigns shall have no further obligation to preserve, dedicate, reserve, make
available, or construct a Tower within the Tower Area. Thereafter, the Tower Area
may be developed and used in accordance with the otherwise applicable zoning
and development regulations.
c. Buffers. A fifty (50) foot buffer shall be maintained around the base of the tower. No
trees may be removed from this buffer area except 1) to the extent such trees are
dead, diseased or dying, or 2) in connection with the construction of the access road
or removal of the communications tower.
d. Equipment Screening. Any building or mechanical equipment shall comply with
applicable development standards related to architectural treatment and screening
of mechanical equipment.
e. Fencing. The base of the tower shall be enclosed by a minimum six (6) foot high
fence designed to preclude trespassing. The fence shall provide a privacy screen
(vinyl slats, mesh tarp, or windscreen) as part of this fence segment. The exact
design shall be approved at the time of site plan review. Such privacy screen shall
be earth tone in color, such as black, dark green or dark brown. Any portion of such
fence with the privacy screen shall also be an earth tone color, such as black, dark
green or dark brown to match the privacy screen. Such fence and privacy screen
shall be maintained in good visual condition.
f. Signage. There shall be no signs permitted to identify this use except those required
by FCC or other regulatory body.
g. Tower Type and Height. Any Tower constructed within the Tower Area shall be
limited to a monopole. Guyed towers and guyed masts shall be prohibited.
i. If provided in Tower Area ‘A’, the total height of the Tower, including the
structure, antennas, arrays, and all appurtenances, shall not exceed 100
feet above existing grade.
ii. If provided in Tower Area ‘B’, the total height of the Tower, including the
structure, antennas, arrays, and all appurtenances, shall not exceed 199
feet above existing grade.
Page 60 of 218
57 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
h. Tower Design.
i. The tower shall be gray or another neutral color, acceptable to the Planning
Department.
ii. The Tower shall not be illuminated.
iii. The tower shall be a monopole structure with internally mounted antennas
or sector array antennas.
iv. Any satellite dish and microwave dish antennas attached to the
telecommunications tower shall not exceed six (6) feet in diameter and shall
be of a neutral color with no logos.
v. Cables shall be run within the interior of the tower to the extent technically
practicable.
i. Tower Fall Zone Setbacks. Depending on the Tower’s design, the following
setbacks from existing off-site dwellings shall be adhered to:
i. For towers one hundred (100) feet or less in height, the minimum setback
shall be 200 feet.
ii. For towers greater than one hundred (100) feet in height, the minimum
setback shall be 300 feet.
j. Structural Integrity. Prior to use of this telecommunications tower, the owner of the
tower shall obtain approval of the structural integrity by a registered professional
engineer licensed in Virginia and a copy of the report filed with the Planning
Department.
k. Co-Location. If constructed to a height that exceeds one hundred (100) feet, the
tower shall be designed and constructed to support the antennas and related
equipment of at least two (2) carriers, including the Applicant’s initial equipment.
l. Dismantling and Discontinuance of Use. If the Tower ceases to be used for
communications purposes for a period of more than twelve (12) consecutive
months, the owner/developer shall dismantle and remove the Tower and all
associated equipment from the Property.
m. Access and Easements. Access to the Tower shall be provided from a public
right-of-way within the development at a location determined during plans review.
The Applicant shall grant, at no cost, any access and utility easements reasonably
necessary for the construction, operation, and maintenance of the Tower, in
locations and dimensions reasonably acceptable to the County and the entity
constructing the Tower. (P)
23. Lamp Post. One (1) lamp post shall be provided in the front yard of each dwelling unit. The
design of such lamp posts shall be consistent throughout the Property. (P)
Page 61 of 218
58 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
25SN1223: In Dale Magisterial District, Garcia Tree Service Business and Accessory
Dwelling Unit is a request for conditional use to permit a business from the home
(landscaping business with commercial vehicle storage) and an accessory dwelling unit
(detached) and amendment of zoning district map in the Agricultural (A) District on 1.68
acres known as 4901 Turner Road. The Comprehensive Plan suggests the property is
appropriate for Residential Neighborhood 4 use (4.0 units per acre or less). Tax ID 770-687-
0331.
Ms. Betsy Hatch presented the case. She reported receiving no comments from the portal.
There was opportunity for questions by the Commissioners for Ms. Hatch.
There were no questions.
Mr. Jose Sephera came forward on behalf of the applicant and stated the applicant agrees
to all conditions should his request be approved.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in
opposition to, the request.
Mr. Eric Whitaker, Ms. Lynn Whitaker, and Ms. Mary Jessup spoke in opposition to the home
business request, while expressing no position on the second‑dwelling request. Their
concerns included early‑morning truck noise beginning around 6:00 a.m., the storage of logs
and trees that could spread pests or disease, increased traffic, and potential impacts on
property values.
Mr. Sephera came forward and stated the applicant will abide by business hours and will not
continue storing trees or logs in the trucks.
In response to a question from Ms. Hardin, Ms. Hatch stated she would research if the
applicant’s easement encroaches on an adjacent property.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
Ms. Richardson led the discussion and noted that she took the case seriously, recognizing
that it affects the applicant’s livelihood. However, based on the concerns raised at the
Page 62 of 218
59 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
community meeting, including resident safety, traffic issues, and unclear business hours,
she stated that she could not support the request.
On motion of Ms. Richardson, seconded by Mr. Sloan, the Commission resolved to
recommend denial of Case 25SN1223 Request 1 subject to the Conditions.
On motion of Ms. Richardson, seconded by Mr. Petroski, the Commission resolved to
recommend approval of Case 25SN1223 Request 2 subject to the Conditions.
CONDITIONS
Staff Note: Conditions 10-12 shall apply to the existing accessory dwelling unit (detached)
as outlined in Request II.
1. Occupancy. Occupancy of the accessory dwelling shall be limited to: the occupants of the
principal dwelling unit, individuals related to them by blood, marriage, adoption, or
guardianship, foster children, personal guests, and household employees. (P)
2. Deed Restriction. For the purpose of providing record notice, a deed restriction shall be
recorded setting forth the limitation in Condition 10. The deed book and page number of
such restriction and a copy of the restriction as recorded shall be submitted to the Planning
Department within ninety (90) days of zoning approval. (P)
3. Accessory Dwelling Location, Size, and Construction Limitations.
a. The accessory dwelling shall be located on the Property as generally depicted on
Exhibit A.
b. The accessory dwelling shall not exceed 450 square feet.
c. A manufactured home shall not be permitted on the Property. (P)
4. Utility Connection. Should the property be legally subdivided in the future, the owner
shall establish separate water and/or wastewater connections to each dwelling unit, subject
to the review and approval of the Utilities Department. The owner shall be responsible for all
costs to establish the new water and/or wastewater connections, including the payment of
connection fees in effect at the time service is initiated. (U)
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Page 63 of 218
60 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
16. CONSIDERATION OF THE FOLLOWING CODE AMENDMENTS.
Subdivision Ordinance Amendment Relative to Chapter 17.1-90
The Subdivision Ordinance (Chapter 17.1) establishes regulations for how land in the County
is subdivided. Section 17.1-90 is proposed to be amended to coincide with a proposed
amendment to Chapter 16 of the County Code to shift responsibility for street naming and
building numbering from the Department of Environmental Engineering to the Department of
Planning. The proposed amendment to the Subdivision Ordinance would establish the Director
of Planning as the official to approve street names and signage for streets.
Mr. Steve Haasch came forward and explained the proposed change would align the Ordinance
with a related amendment to Chapter 16 of the County Code that transfers responsibility for
street naming and building numbering from Environmental Engineering to the Department of
Planning. The amendment would formally designate the Director of Planning as the official who
approves street names.
There were no questions for Mr. Haasch.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in opposition
to, the request.
No one came forward to speak in favor of, or in opposition to, the request.
There being no one to speak, Ms. Hardin closed the Public Hearing.
On motion of Mr. Petroski, seconded by Ms. Richardson, the Commission resolved to
recommend approval of Subdivision Ordinance Amendment Relative to Chapter 17.1-90.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Code Amendment Relative to General Housekeeping (26PJ0007)
Ordinance to amend the Code of the County of Chesterfield, 1997, as amended, by amending
and reenacting the following sections of the zoning ordinance. Among other things, this
amendment would do the following:
• 19.2-8 Agricultural: correcting inconsistencies in table notes
Page 64 of 218
61 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
• 19.2-9 Rural Community, 19.2-10 Semi Rural, 19.2-11 Suburban Community: added note
regarding road frontage on terminus of a stub street
• 19.2-12 Semi-Urban
o Added table note regarding road frontage on terminus of a stub street.
o Reduce corner side setback for accessory structures from 25’ to 7.5’
• 19.2-24 Roseland Zoning Overlay (RZO): Assign labels to unlabeled figures & tables
• 19.2-27 Floodplain Management: fix section cross-reference
• 19.2-29 Principal Use Matrix
o New use: Crisis receiving center - permitted in Corridor Commercial
(CC)/Employment Center (EC); conditional in Neighborhood Business (NB) and
Mixed Use (MU)
o Temporary manufactured home: change to use allowed by special exception in
Agriculture
o Manufactured home (on a single lot): change to permitted use in Agricultural,
change to use permitted with restrictions in all districts except EC (aligns with
HB655/SB346)
o Golf Course & MATS - Change to conditional use
o Artisan Studio Workshop – change to permitted use in Employment General (EG)
o Commercial Amusement, Indoor – change to permitted use in Employment General
(EG)
o Mobile food vending – move to accessory matrix
o Commercial contractor with Outside Storage – change to use permitted with
restrictions in Warehouse and Distribution (WD)
o New use: Temporary support structure – permitted with restrictions in all districts
o Utility Scale Solar Facility- change to Conditional use with additional guidance (C*)
in NB, CC, MU, EC, EG, WD (aligns with HB711/SB347)
• 19.2-30 Principal Use Restrictions
o Auto sales - change CORDLI to OLPA
o Commercial contractors with outside storage and/or fleet parking
o Add limitation on outside storage to 50% of site in WD district
o Dwelling, Multifamily
o Delete "C. Northern Route 1 Corridor"
o Dwelling, Townhouse
o Add clause stating townhouse dwellings are allowed with a new mixed-use zoning
case using Option 2 in the CC District.
o Change “restaurant drive-in” to “drive-through window”
o Manufactured Home (aligns with HB655/SB346)
o add restrictions for real property conversion and date of manufacture
o Clarify that BZA may grant a Special Exception for projects not meeting restrictions
o Mobile food vending
o Move to accessory use restrictions
Page 65 of 218
62 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
o Solar Energy Facility, Utility Scale– amend all recommended conditions to be
consistent with requirements of HB711
o Temporary Support Structure (aligns with HB876)
o Must be necessary for testing system performance, supplementing coverage for an
inoperable permitted wireless facility, to provide coverage during an emergency, or
during a special event.
o Allowed for 180 days and may be extended for up to 2 years total
o Removed at the end of the approval period
• 19.2.-31 Accessory Use Matrix
o Add new use: Energy Storage Facility, permitted with restrictions in Agricultural
district (aligns with HB891/SB443)
o Animal Run, Outdoor
o Move Mobile Food Vending from principal use matrix to accessory use matrix
• 19.2-32 Accessory Use Restrictions
o Animal Run, Outdoor
o Change setback from residential district to setback from residential use
o Energy Storage facility (aligns with HB891/SB443)
o Allowed as an accessory use at any approved solar facility
o Rated capacity of the energy storage facility must not exceed the generating
capacity of the associated solar facility
o Mobile food vending
o Moved from principal use matrix
o Recreational Vehicle and Trailer parking
o Fix typo in title
o Added exemption for screening for open sided utility trailers <20’ in length.
o Shipping Container
o Removed discretionary permit approval process
o Allowed for active building permit in residential districts.
o Allowed one container for agricultural parcels >5 acres
o Storage, Outside
o Add limitation on outside storage to 50% of site in WD district
• 19.2-34 Amenity Space
o Add labels to Unlabeled figures & tables
o Correct math errors in sample calculation table
o Provide clarity on calculating amenity space on projects with multiple districts, and
within the Corridor Commercial district.
• 19.2-35 Buffers
o Clarify that prohibition of lots within a buffer applies to lots recorded after effective
date.
o Clarify that individual lots in SC, SU, TR, UR, AR, or MU districts cannot go into the
RPA Buffer.
Page 66 of 218
63 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
o Buffer tables - remove "proposed zoning" and replace with "zoning district of
proposed development"
o Add label to Unlabeled figures & tables
• 19.2-37 Dimensional Standards
o Fix typos
o Add that common lot developments in TR, UR, and AR districts must have 40’
setback from limited access highway.
o Remove height limit for communication tower; it is covered elsewhere in Chapter
• 19.2-39 Fences, Retaining Walls, and Visual Obstructions
o Specify that fences in AR Option 1 are limited to four feet in height.
o Corner side yard fences
o Allow 7' fence to come up to property line if it includes ornamental features, or
o 3' setback for 7' fence with plantings
• 19.2-41 Landscaping: correct typos
• 19.2-42 Parking
o Clarify that PDM plan is required when requesting adjustment to parking
o Clarify off-site parking requirements
o Exempt solar facilities from paved parking/driveway requirement
o Table 19.2-42.2 Stacking Spaces; replace “fast food restaurant” with “restaurant
with drive-through window”; add “with drive-through window” to “Financial
Institution”
o Reduce parking minimums for residential and mixed use development within 0.5
mile of mass transit/public transportation facility (aligns with HB888)
o Add 20% parking reduction for residential/multifamily/mixed use development where
parking is placed in a parking structure (aligns with HB888)
• 19.2-43 Signs
o Add missing word “demolish” to J.4 regarding outdoor advertising sign
modernization
• 19.2-47 General Procedural Requirements
o Changed “CUPD” to “Zoning Deviation”
o Add an automatic withdrawal for applications for zoning approval and site plan that
do not show any good faith effort to advance the project within one year.
o Correct typos
• 19.2-48 Notice
o Change incorrect section references and numbering.
o Replace “variance” with “modification”
o Add label to Unlabeled figures & tables
• 19.2-66 Variances
o Insert missing language to match § 15.2-2309
• 19.2-67 Administrative Modifications
o Change “variance” to “modification” in C.3
• 19.2-72 Development Under Prior Zoning Ordinances
Page 67 of 218
64 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
o 19.2-72.C.2 – reword to apply to any property zoned TR or AR
o Add “dwelling, multifamily” to list of uses not eligible for 5-year continuation
• 19.2-73 Continuity of Prior Zoning Approvals
o Clarify that the list of uses in 19.2-72.E.1 are not generally continued unless
explicitly permitted by conditions of zoning
• 19.2-76 Enforcement
o Add "mobile food vendor" to list of actions that don’t require 10-day notice
• 19.2-83 Definitions
o Add definitions for the following terms: tent; mass transit or public transportation
(HB888); mass transit or public transportation station or facility (HB888); temporary
support structure (HB876); crisis receiving center
o Remove definitions for the following terms: restaurant, drive-in or drive through;
o Restaurant - remove last sentence that precludes drive-through restaurants
o Unlabeled figures & tables
Mr. Jenkins came forward, and gave a brief overview of the amendment that was presented at
the previous month’s work session. He stated there was error rate of 0.0008 during the
conversion of 19.1 to 19.2 of the Zoning Ordinance. The amendment is to correct the several
parcels that were given the wrong district during that conversion.
There were no questions for Mr. Jenkins.
Ms. Hardin opened the Public Hearing.
Ms. Hardin asked if there was anyone present who wished to speak in favor of, or in opposition
to, the request.
Mr. Jerry Turner came forward and noted that his earlier cautions had been validated and more
changes were to come.
There being no one else to speak, Ms. Hardin closed the Public Hearing.
On motion of Ms. Hardin, seconded by Mr. Sloan, the Commission resolved to recommend
approval of Code Amendment Relative to General Housekeeping (26PJ0007).
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
17. CITIZEN COMMENT PERIOD ON UNSCHEDULED MATTERS INVOLVING THE SERVICES,
POLICIES AND AFFAIRS OF THE COUNTY GOVERNMENT REGARDING PLANNING OR
LAND USE MATTERS.
Page 68 of 218
65 | P a g e
07-21-2026 CPC DRAFT Minutes/SM
No one came forward to speak.
18. OTHER BUSINESS.
There was no other business.
19. ADJOURNMENT.
There being no further business to come before the Commission, on motion of Ms. Hardin,
seconded by Mr. Petroski, the meeting adjourned at 10:13 p.m. to 4:00 p.m. on Tuesday, August
18, 2026.
Ms. Hardin aye
Mr. Petroski aye
Mr. Sloan aye
Ms. Richardson aye
Page 69 of 218
Page 70 of 218
Page 71 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 1 of 15
24SN1194 – West Hundred Road
Rezoning & Adjustments
Magisterial District – Bermuda
Agent – Stephen Donohoe (804-748-1050)
CPC Public Hearing – August 18, 2026
Time Remaining
100 Days
Case Manager
David Conmy
(804-796-7095)
Request
Rezoning &
Adjustments to Ordinance Requirements
Continued use of an existing office building with a
massage clinic tenant is planned.
Staff Recommendation
Approval
The Property
3740 West Hundred Road
Site Size
0.46 Acre
Comprehensive Plan –
Land Use Designation
Office/Residential Mixed Use
Plan Area
The Chester Plan
Figure 1: Aerial of Request Area – Click Image for Link to GIS
Figure 2: Area Map of Request & Land Use Plan Map
Rezoning from Semi-Urban Neighborhood (SU) to Neighborhood Business (NB) District to permit office and massage
clinic uses with adjustments to ordinance requirements relative to buffers and Village Overlay requirements.
An existing office building with an associated parking area is located on the Property. Previous zoning approval
permitted the conversion of a dwelling into an office building. The owner has since leased a portion of this building to a
tenant who operates a massage clinic, which requires zoning approval to permit this use. Uses for the Property will be
limited to office and massage clinic uses only. The adjustments in this request would provide relief to buffer and Village
Overlay District requirements that are a result of this rezoning action.
Staff Note: This request is subject to the procedural and development regulations provided
in Chapter 19.2 of the Zoning Ordinance.
Summary of Proposal
Page 72 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 2 of 15
STAFF - APPROVAL
The proposal will conform to The Chester Plan, which suggests the property is appropriate for Office/Residential Mixed
Use. Continuation of the existing office uses , in addition to the massage clinic, will support the Plan’s land use
recommendation for administrative and professional office uses along the W est Hundred (Route 10) corridor. As
conditioned, uses on the Property will continue to be limited and allow the existing development configuration of the
Property to remain until it is redeveloped. If redeveloped, the Property will then be required to conform to today’s Village
Overlay District requirements.
NOTES FOR THE PLANNING COMMISSION AND BOARD OF SUPERVISORS
1. The only condition that may be imposed is a buffer condition. The property owner may proffer conditions.
2. Proffered conditions and a Conceptual Plan have been offered by the applicant.
Recommendation
Page 73 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 3 of 15
Summary of Proposal .............................................................................................................................................................. 1
Recommendation .................................................................................................................................................................... 2
Table of Contents .................................................................................................................................................................... 3
Planning................................................................................................................................................................................... 4
Current Zoning Map ................................................................................................................................................................ 7
Supplemental Analysis ............................................................................................................................................................ 8
Community Enhancement .................................................................................................................................................. 8
Environmental Engineering ................................................................................................................................................. 8
Fire & Emergency Medical Services .................................................................................................................................... 8
Police ................................................................................................................................................................................... 8
Transportation - County Department of Transportation .................................................................................................... 8
Transportation - Virginia Department of Transportation ................................................................................................... 8
Utilities – Water and Wastewater ...................................................................................................................................... 8
Community Engagement & Public Hearings ........................................................................................................................... 9
Proffered Conditions (8/10/2026) ........................................................................................................................................ 10
Justification for Adjustments to Ordinance Requirements .................................................................................................. 11
Conceptual Plan – Exhibit A .................................................................................................................................................. 13
Signage – Exhibit B ................................................................................................................................................................ 14
Case Contacts ........................................................................................................................................................................ 15
Table of Contents
Page 74 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 4 of 15
Zoning History
81SN0081: Approved (10/1981)
Conditional use planned development to permit professional offices (insurance/real estate office) in a Residential (R-7)
District and an exception to the paving requirement for driveways and parking areas. Conditions of approval addressed
use limitations, no additions or alterations to the exterior structure, parking location and screening, right-of-way
dedication, and signage.
86SN0012: Approved (2/1986)
Amendment of a previously approved conditional use planned development to allow all types of professional offices, as
opposed to limiting the office use to real estate and/or insurance firms, and to increase the permitted freestanding sign
area from ten (10) square feet to 21.25 square feet. Conditions of approval addressed use limitations, signage, paving
for parking areas, and right-of-way dedication.
Comprehensive Plan – Land Use Plan Designation
The Chester Plan designates the Property for Office/Residential Mixed Use, which suggests the Property is appropriate
for professional and administrative offices, along with residential developments of varying densities.
Proposal
An office building with a massage clinic tenant are located on the Property today. The existing office building is a
converted residence that was built in 1912 (Figure 3). Previously approved conditions of zoning approval prohibit the
massage clinic use, and rezoning to the Neighborhood Business (NB) District would permit this additional use. Proffered
Condition 1 would limit uses on the Property to these two (2) uses only. In addition, the existing improvements on the
Property today will be permitted and are documented in the Conceptual Plan (Proffered Condition 2).
Figure 3: Existing office building on the Property.
The existing conditions of the Property cannot meet today’s buffer and development standards outlined in the Village
Overlay District. A fifty (50) foot buffer is required between the Property and the developed SU zoned property to the
north, and a twenty-five (25) foot buffer is required between the Property and the vacant SU zoned property to the east.
Additionally, the Village Overlay District requires the western side of the parking lot facing Old Centralia Road to be no
closer to the road than the front of the building and requires certain building design and development standards.
Planning
Page 75 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 5 of 15
Proffered Condition 3 provides relief through adjustments to these ordinance requirements based on existing
improvements for the building, parking area, and fence, as shown on a Conceptual Plan (Exhibit A) (Figure 4).
The Conceptual Plan highlights an existing six (6) foot tall vinyl fence that screens the Property’s parking lot from an
adjacent single-family dwelling to the north. Proffered Condition 3.a.i requires this fence to be maintained. The
Conceptual Plan also highlights an existing row of twelve (12) evergreen trees that screen the parking lot from the
adjacent, but undeveloped, residentially zoned property to the east. If fifty (50) percent of those evergreen trees are
removed or a contiguous row of three (3) or more evergreen trees are removed in the future, Proffered Condition 3.a.ii
will require the onsite installation of a six (6) foot tall opaque fence between the parking area and eastern property line.
Such fence would be required to be architecturally compatible with the existing fence located along the northern
property line.
Additionally, in the event the Property is redeveloped in the future (modifications to access, parking, and/or building
locations), Proffered Condition 5 establishes that such development shall conform to Ordinance requirements and not
be subject to the proffered Conceptual Plan. Redevelopment of the Property would need to meet all Ordinance
requirements, including the Village Overlay District.
Figure 4: Excerpt of the Conceptual Plan for the Property.
Signage
The Conceptual Plan also identifies an existing freestanding sign near the southeastern corner of the Property facing
West Hundred Road (Exhibit B). Existing zoning conditions limit the property to only one (1) freestanding sign and
establish that such sign shall not exceed 21.25 square feet in area and six (6) feet in height. This sign was recently
modified in a manner which brings it out of compliance with sign requirements. Proffered Condition 4 requires the sign
be brought back into conformance within thirty (30) days of zoning approval, requires the sign to maintain the design as
shown in Exhibit B, and prohibits other freestanding signs on the property. Furthermore, it establishes that a future
replacement sign shall conform to the Village Overlay Ordinance signage requirements.
Page 76 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 6 of 15
Adjustments
• A fifty (50) foot buffer is required along the northern property line of the Property; an adjustment requesting
that no buffer be provided is proposed. The existing physical conditions of the Property, including an existing
fence, would remain subject to the proffered Conceptual Plan. If the Property is ever redeveloped and the
adjacent zoning remains zoned SU, the required buffer will then be provided.
• A twenty-five (25) foot buffer is required along the eastern property line of the Property; an adjustment
requesting that no buffer be provided is proposed. The existing physical conditions of the Property, including
off-site landscaping, would remain subject to the proffered Conceptual Plan. If the Property is ever redeveloped
and the adjacent zoning remains zoned SU, the required buffer will then be provided.
• The Village Overlay District provides development standards for non-residential development in specified areas
of the County; an adjustment requesting that the Property conform to the existing improvements shown on the
Conceptual Plan is proposed. If the Property is redeveloped (modification to the access, parking and/or building
locations), Village Overlay District requirements will then apply to the Property.
Page 77 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 7 of 15
Current Zoning Map
GPIN 791-656-7034
Page 78 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 8 of 15
No comment on this request.
No comment on this request.
Service Area
The Chester Fire Station, Company Number 1
Additional Information
This request will have minimal impacts on Fire & Emergency Medical Services.
Division Beat District
Appomattox 73 Bermuda
Additional Information
This request is anticipated to have minimal impacts on Police.
This request is anticipated to have a similar traffic impact as the existing permitted uses on the property.
The Virginia Department of Transportation (VDOT) has reviewed Case 24SN1194 to rezone from Semi-Urban
Neighborhood (SU) to Neighborhood Business (NB) District to permit an existing office and massage clinic use with
adjustments to ordinance requirements. Should any work be required in VDOT right-of-way, a Land Use Permit will be
required.
1. The Property is connected to public water and wastewater.
2. This request does not impact Utilities.
3. The Utilities Department supports this request.
Supplemental Analysis
Community Enhancement
Environmental Engineering
Fire & Emergency Medical Services
Police
Transportation - County Department of Transportation
Transportation - Virginia Department of Transportation
Utilities – Water and Wastewater
Page 79 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 9 of 15
Community Meeting
No community meeting was conducted for this request.
Community Engagement & Public Hearings
Page 80 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 10 of 15
Staff Note: GPINs referenced in the proffered conditions can be found on the Current Zoning Map or the
Conceptual Plan.
1. Uses. Uses for the Property shall be limited to the following:
a. Office.
b. Massage clinic. (P)
2. Conceptual Plan. The Property shall generally conform to the existing improvements for the building, parking
area, and fencing shown on the Conceptual Plan, Exhibit A. (P)
3. Adjustments. The following adjustments shall be provided for the existing improvements shown on Exhibit A:
a. Buffers. No buffer shall be required for the Property along the northern or eastern property lines.
i. The existing fence along the northern property line shall be maintained, as shown on Exhibit A.
ii. If the twelve (12) existing evergreen trees on GPIN 791-656-7034 are maintained in the location
shown on Exhibit A, no fence shall be required between the existing parking area and the
property line. If fifty (50) percent of these evergreen trees are removed or a contiguous row of
three (3) or more of these evergreen trees are removed, a six (6) foot tall opaque fence shall be
installed between the parking area and the eastern property line to provide screening to the
adjacent property. This fence shall be architecturally compatible with the existing fence along
the northern property line.
b. Village Overlay District. The Property shall conform to the Conceptual Plan and not be subject to the
Village Overlay District standards unless the Property is redeveloped, as defined in Proffered Condition
5. (P)
4. Signage. The existing freestanding sign shall be limited to a height of six (6) feet, 21.25 square feet in area, and
maintain the current design that is shown on Exhibit B. The lower sign panel, as identified on Exhibit B, shall be
removed within thirty (30) days of zoning approval. If this freestanding sign is replaced, the new freestanding
sign shall meet Ordinance requirements for signage in the Village Overlay District. No other freestanding signs
shall be permitted on the Property. (P)
5. Redevelopment. If the Property is redeveloped (modification to either the access, parking, and/or building
locations), development of the Property shall conform to Ordinance requirements and not be subject to the
Conceptual Plan. (P)
Proffered Conditions (8/10/2026)
Page 81 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 11 of 15
Request for Adjustments to Ordinance Requirements
With Justification and Mitigating Enhancements
Pursuant to Chapter 19.2-51-1 Adjustments to Ordinance Requirements, the applicant may request adjustments to
development standards of the Zoning ordinance as part of a proffer statement provided there is appropriate and
sufficient justification along with mitigating enhancements demonstrated in the request. The following adjustments to
development standards are being requested with this zoning application:
Adjustment 1: Chapter 19.2-35.B.1 – Buffers Between Different Zoning Districts. The applicant proposes to eliminate the
required fifty (50) foot buffer between the Property’s northern property line and the adjacent property zoned Semi-
Urban Neighborhood (SU) District, which includes a single-family dwelling built in 1956. Case 81SN0081 allowed for the
adaptive re-use of an existing single-family dwelling on the Property (built in 1912) into professional offices. Condition 3
of the approved case established that “all parking shall be located to the rear of the existing structure…and shall be
screened from view of adjacent property to the north and east…by existing vegetative conditions and/or additional
planting” as reflected in a schematic plan. This plan makes no mention of buffers or vegetative screening and appears to
place the parking area a short distance from the northern property line. This condition was retained during case
86SN0012, and no additional conditions concerning buffers were established. An existing six (6) foot tall vinyl fence
provides screening between the two properties, and Condition 2 mitigates this adjustment by requiring the property to
conform to existing improvements as identified in a proffered Conceptual Plan (Exhibit A), including this existing fence.
Condition 3.a.i reinforces this mitigation by clearly stating “the existing fence along the northern property line shall be
maintained, as shown on Exhibit A.” Finally, Proffered Condition 5 would require the property to conform to Ordinance
requirements instead of the Conceptual Plan in the event of redevelopment; and, in the event of such redevelopment,
ordinance requirements – including buffers – could then enable additional screening between the two properties to
mitigate any issues that may arise at that time.
Adjustment 2: Chapter 19.2-35.B.1 – Buffers Between Different Zoning Districts. The applicant proposes to eliminate the
required twenty-five (25) foot buffer between the Property’s eastern property line and the adjacent, undeveloped Semi-
Urban Neighborhood (SU) District zoned property. Case 81SN0081 allowed for the adaptive re-use of an existing single-
family dwelling on the Property (built in 1912) into professional offices. Condition 3 of the approved case established
that “all parking shall be located to the rear of the existing structure…and shall be screened from view of adjacent
property to the north and east…by existing vegetative conditions and/or additional planting” as reflected in a schematic
plan. This plan makes no mention of buffers or vegetative screening and appears to place the parking area a short
distance from the eastern property line. This condition was retained during case 86SN0012, and no additional conditions
concerning buffers were established. Furthermore, a new, superseding condition was included in case 86SN0012
establishing “parking areas shall be designed to facilitate traffic movements through the site to the adjacent property to
the east as such time as it is developed for office/commercial use.” No such development has occurred, though it would
be reasonable for such a connection to occur in the future with the Chester Plan suggesting the property is appropriate
for Office/Residential Mixed Use. Notwithstanding adjacent development, in the event that either fifty (50) percent of
these evergreen trees are removed or a contiguous row of three (3) or more of these evergreen trees are removed,
Condition 3.a.ii requires “a six (6) foot tall opaque fence (to) be installed between the parking area and the eastern
property line to provide screening to the adjacent property,” to assist in mitigating screening between the two (2)
properties. Finally, Proffered Condition 5 would require the property to conform to Ordinance requirements instead of
the Conceptual Plan (proffered in Condition 2) in the event of redevelopment; and, in the event of such redevelopment,
ordinance requirements – including buffers – could then enable additional screening between the two properties to
mitigate any issues that may arise at that time.
Justification for Adjustments to Ordinance Requirements
Page 82 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 12 of 15
Adjustment 3: Chapter 19.2-22 – Village Overlay District. The applicant proposes to allow the existing building, parking
area, and fencing to remain on the Property (as shown on the Conceptual Plan) and not be subject to any of the Village
Overlay District requirements. The existing office building dates to 1912 and the parking area that serves the office was
constructed in the mid-1980s. The rezoning action to permit the massage clinic use will require the Village Overlay
District requirements to apply to the Property. No new improvements are planned for the Property at this time,
therefore there is no need to apply the Village Overlay District requirements to the existing improvements. Proffered
Condition 2 will require the Property to “generally conform to the existing improvements for the building, parking area,
and fencing shown on the Conceptual Plan, Exhibit A.” Furthermore, Proffered Condition 5 would require the Property
to conform to Ordinance requirements instead of the Conceptual Plan (Proffered Condition 2) in the event of
redevelopment; and, in the event of such redevelopment, dimensional requirements of the Village Overlay District
would apply.
Page 83 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 13 of 15
Conceptual Plan – Exhibit A
Existing 6’ tall vinyl
fence
Existing evergreen trees on
GPIN 791-656-7034
Existing
freestanding sign
Existing office
building
Future fence location
(if evergreen trees removed)
Page 84 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 14 of 15
Signage – Exhibit B
Page 85 of 218
West Hundred Road Rezoning & Adjustments 24SN1194 Page 15 of 15
Applicant
• Applicant’s Agent:
Stephen Donohoe (804-748-1050)
District Planning Commissioner
• Gib Sloan (804-892-5633)
sloang@chesterfield.gov
Staff
• Planning Department Case Manager: Ryan Ramsey (804-751-4474) ramseyrp@chesterfield.gov
• Community Enhancement: Brian Chamberlain (804-748-1541) chamberlainb@chesterfield.gov
• Environmental Engineering: Douglas Miles (804-768-7797) milesd@chesterfield.gov
• Fire & Emergency Medical Services: Christopher Harding (804-971-0399)
hardingc@chesterfield.gov
• Police: Jim Eicher (804-318-8693) eicherj@chesterfield.gov
• Transportation - County Department of Transportation: Steve Adams (804-751-4461)
adamsst@chesterfield.gov
• Transportation - Virginia Department of Transportation: Dustin Dunnagan (804-674-2384)
dustin.dunnagan@vdot.virginia.gov
• Utilities: Alan Harrison (804-796-7126) harrisonl@chesterfield.gov
Case Contacts
Page 86 of 218
24SN1194 – Bermuda
Rezone from Semi-Urban Neighborhood (SU) to Neighborhood
Business (NB) plus adjustments to ordinance requirements.
West Hundred Road Rezoning & Adjustments
Case 24SN1194, in the Bermuda Magisterial District, West Hundred Road Rezoning
& Adjustments is a request to rezone 0.46 of an acre of land from Semi-Urban
Neighborhood (SU) to Neighborhood Business (NB) District to permit office and
massage clinic uses with adjustments to ordinance requirements relative to buffers
and Village Overlay requirements.
1
Page 87 of 218
24SN1194 – Overview
1. Rezoning to Neighborhood
Business (NB) with use
restrictions to permit office
and massage clinic uses
only
2. Adjustments to buffer and
Village Overlay District
3. Proffered Conceptual Plan
4. Staff recommends approval
Overview Slide.
2
Page 88 of 218
24SN1194 – Zoning Map
The Property contains 0.46 of an acre and is zoned Semi-Urban Neighborhood (SU)
and located in the Village Overlay District. Surrounding properties are zoned Semi-
Urban Neighborhood (SU) to the north, east and west and Suburban Community
(SC) to the south.
3
Page 89 of 218
24SN1194 – Aerial & Land Use Plan Map
The first image on the left reflects an aerial of the Property with Thomas Dale High School
to the northeast and a mixture of residential and non-residential uses along West Hundred
Road (Route 10). The Property is currently occupied with an existing office building and
associated parking areas. The second image on the right reflects the Chester Plan for the
Property and that it is designated for Office/Residential Mixed Use.
4
Page 90 of 218
24SN1194 – Proffered Conceptual Plan
An office building, which includes a massage clinic, operate on the Property today. Previously
approved zoning conditions prohibit the massage clinic, and rezoning the Property to Neighborhood
Business District would permit this additional use. Proffers would limit uses on the property to
these two (2) uses only and permit the existing improvements on the Property as documented in
the proffered Conceptual Plan (Proffered Condition 2), which is shown in the current slide.
The existing conditions of the Property cannot meet today’s buffer and development standards in
the Neighborhood Business and Village Overlay Districts. Proffers provide relief through
adjustments to these ordinance requirements based on existing improvements for the building,
parking area, six (6) foot tall vinyl fence, and row of twelve (12) evergreen trees – all shown on the
Conceptual Plan. The fence and evergreen trees screen the property’s parking lot from adjacent
properties to the north and east. Proffers would require the existing fence to be maintained and
the installation of a new, architecturally compatible fence if the evergreen trees are removed. In
the event the Property is redeveloped, proffers require such development to conform to Ordinance
requirements and not be subject to the proffered Conceptual Plan.
Finally, proffers require an existing freestanding sign near the southeastern corner of the Property
to be brought back into conformance within thirty (30) days of zoning approval and maintain the
design as shown in Exhibit B of the staff report. Other freestanding signs on the property would be
prohibited and a future replacement sign would be required to conform to the Village Overlay
Ordinance signage requirements.
5
Page 91 of 218
24SN1194 – Recommendation
1. Staff – Approval
• Proposal conforms to The Chester Plan
• Proffered conditions limit uses, allow existing
development configurations, and provides screening
• If redeveloped, Property will be required conform to
ordinance requirements
Staff recommends approval of this request. The proposal will conform to The Chester Plan,
which suggests the property is appropriate for Office/Residential Mixed Use. Continuation
of the existing office uses, in addition to the massage clinic, will support the Plan’s land use
recommendation for administrative and professional office uses along the West Hundred
(Route 10) corridor. As conditioned, uses on the Property will continue to be limited and
allow the existing development configuration of the Property to remain until it is
redeveloped. Adjustments providing relief from buffer and Village Overlay requirements
are mitigated through Proffers and the Conceptual Plan. If redeveloped, the Property will
then be required to conform to today’s Village Overlay District requirements.
6
Page 92 of 218
24SN1194 – Zoning Map
End of Presentation.
7
Page 93 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 1 of 24
25SN1238 – Swift Creek Reserve
Rezoning
Magisterial District – Matoaca
Agent – Brady Deal (540-905-3415)
CPC Public Hearing – August 18, 2026
Time Remaining
100 Days
Case Manager
Richard Saunders
(804-796-7192)
Request
Rezoning
A single-family development with up to eighteen (18)
dwellings is proposed.
Staff Recommendation
Approval
The Property
6010 and 6020 Cedar Springs Road
Site Size
37.2 Acres
Comprehensive Plan –
Land Use Designation
Residential Agricultural
Plan Area
County Wide Plan
Figure 1: Aerial of Request Area – Click Image for Link to GIS
Figure 2: Area Map of Request & Land Use Plan Map
Rezoning from Agricultural (A) to Semi-Rural Neighborhood (SR).
Subdivision of the Property into eighteen (18) single-family residential lots is proposed. The applicant proposes that
homes within the development be served by private well and septic systems, which requires that the Semi-Rural
Neighborhood (SR), Base Option be utilized. The proffered Conceptual Plan (Exhibit A) shows that each residential lot
will be a minimum of two (2) acres.
Staff Note: This request is subject to the procedural and development regulations provided
in Chapter 19.2 of the Zoning Ordinance.
Summary of Proposal
Page 94 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 2 of 24
STAFF - APPROVAL
The Comprehensive Plan’s land use designation for the Property is Residential Agricultural uses, which supports single-
family dwellings in subdivisions with lots of 2 acres or larger. The applicant’s request will comply with the Residential
Agricultural land use designation. No adjustments to zoning ordinance requirements have been included in this
request. The proposal’s overall residential density of 0. 48 dwellings per acre falls below the Plan’s recommended
residential density of 0.5 dwellings per acre or less. The applicant has provided conceptual elevations and has proffered
building and lot design standards that will complement and enhance surrounding residential development.
The development’s traffic impact will be addressed by road improvements and road cash proffers.
NOTES FOR THE PLANNING COMMISSION AND BOARD OF SUPERVISORS
1. The only condition that may be imposed is a buffer condition. The property owner may proffer conditions.
2. Proffered conditions, a conceptual plan, and conceptual elevations have been submitted by the applicant.
Recommendation
Page 95 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 3 of 24
Summary of Proposal .............................................................................................................................................................. 1
Recommendation .................................................................................................................................................................... 2
Table of Contents .................................................................................................................................................................... 3
Planning................................................................................................................................................................................... 4
Current Zoning Map ................................................................................................................................................................ 6
Supplemental Analysis ............................................................................................................................................................ 7
Budget & Management ....................................................................................................................................................... 7
Community Enhancement .................................................................................................................................................. 7
Environmental Engineering ................................................................................................................................................. 7
Fire & Emergency Medical Services .................................................................................................................................... 7
Libraries ............................................................................................................................................................................... 8
Parks & Recreation .............................................................................................................................................................. 9
Police ................................................................................................................................................................................... 9
Schools ................................................................................................................................................................................ 9
Transportation - County Department of Transportation .................................................................................................. 10
Transportation - Virginia Department of Transportation ................................................................................................. 11
Utilities – Water and Wastewater .................................................................................................................................... 11
Community Engagement & Public Hearings ......................................................................................................................... 13
Proffered Conditions (8/6/2026) .......................................................................................................................................... 14
Conceptual Plan – Exhibit A .................................................................................................................................................. 17
Conceptual Elevations – Exhibit B ......................................................................................................................................... 18
Case Contacts ........................................................................................................................................................................ 21
Appendix ............................................................................................................................................................................... 22
Fire & Emergency Medical Services .................................................................................................................................. 22
Schools .............................................................................................................................................................................. 24
Table of Contents
Page 96 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 4 of 24
Comprehensive Plan – Land Use Plan Designation
The Comprehensive Plan designates the Property for Residential Agricultural, which suggests the Property is appropriate
for residential development at a density of 0.5 units per acre or less.
Proposal
A residential community consisting of a maximum of eighteen (18) single-family dwellings is proposed as detailed in the
Conceptual Plan (Exhibit A, Figure 3, Proffered Condition 1). Single-family detached dwellings located on individual lots
are planned, with lot sizes ranging from 2.0 to 2.58 acres as conceptually shown on the Conceptual Plan. The
development would have one (1) entrance off of Cedar Springs Road. As required by the Zoning Ordinance, a 200-foot
sound setback is being provided within lots from the Route 288 right-of-way. Clearing of trees would not be permitted
within this setback. The local road serving the subdivision would be stubbed to the property to the south, with a
temporary cul-de-sac easement being provided at the road’s terminus.
Figure 3: Conceptual Plan for the Property.
Design
High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods
that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance
to promote the health, safety, convenience and general welfare of the public includes the creation of convenient,
attractive and harmonious communities, protection against overcrowding of land, and protection of the natural
environment. As such, developments that promote unique, viable and long-lasting places and enhance the community
are encouraged.
The applicant has proffered design requirements as part of this request. A conceptual plan (Exhibit A) showing a
conceptual layout of streets, lots, buildable areas and environmental features for the proposed subdivision on the
Property has been provided. Lot and project design standards have been proffered to include: internal sidewalks on one
side of the internal project road, front foundation planting beds, hardscaped front walks and driveways, and screening
Planning
Page 97 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 5 of 24
of mechanical equipment (Proffered Conditions 4, 9, 10 and 13). Design standards for dwellings include masonry
foundation treatment, treatment of porches, stoops, garage doors and fireplaces, chimneys, and flues, conceptual
elevations, unit variation, and the use of high quality siding and roofing materials (Proffered Conditions 8, 11, 12, 14, 15,
16 and 17). As required by the zoning ordinance, a 200-foot sound setback is being provided within lots adjacent to the
Route 288 right-of-way.
Water Wells
The applicant proposes that each home be served by a private water well. The Semi-Rural Neighborhood (SR) Base
Option permits the use of private wells and septic systems unless otherwise required by Section 18-60 of the County
Code. In response to concerns regarding potential impacts on the water supply for existing nearby wells, the applicant
has proffered that all wells serving the proposed homes be drilled to a minimum depth of 200 feet (Proffered Condition
18). At this depth, the wells will draw from a deeper aquifer than those serving most homes in the surrounding area.
This proffer was offered in direct response to concerns raised by area residents at the community meetings.
Findings
The applicant proposes a single-family detached residential development on large lots, consistent with the uses and
density supported by the Comprehensive Plan. The proffered design standards will contribute to the creation of a
well-designed, attractive, and vibrant community. Staff supports this request.
Page 98 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 6 of 24
Current Zoning Map
Page 99 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 7 of 24
No comment on this request.
No comment on this request.
1. The Property is located within the Middle Swift Creek Watershed and is located adjacent to Swift Creek which
contains associated Resource Protection Area (RPA) confirmed by an RPA delineation (RPAD-1382) on December
5, 2025. Steep slopes are located between Bailey Bridge Middle School and the Property and are contained
within the RPA area.
2. To address water quality concerns in the watershed, enhanced erosion and sediment control measures above
those required by state regulations shall be provided, which include the use of super silt fence or an approved
alternative; sediment traps and basins that are at least twenty-five (25) percent larger than the minimum state
standards; and the application of Anionic PAM (Polyacrylamide) or an approved equivalent to denuded areas
during construction and final stabilization.
a. The applicant has offered Proffered Condition 3.a and 3.b to address these concerns.
3. The maximum post-development discharge rate for the 100-year storm shall be based on the maximum capacity
of the existing facilities downstream and shall not increase the recorded and /or established 100-year backwater
and /or floodplain. On-Site detention of the post-development 100-year discharge rate to below the
pre-development 100-year discharge rate may be provided to satisfy this requirement.
a. The applicant has offered Proffered Condition 3.c to address this concern.
Service Area
The Manchester Volunteer Rescue Squad Fire Station, Company Number 24
Community Fire Protection Capabilities Assessment*
Insurance Service Office (ISO) Public Protection Classification (PPC) Class 2Y
Anticipated Impacts On Fire & EMS
Call Load in Immediate Service Area During Previous Fiscal Year 3,524
Projected Calls Generated Yearly by This Proposed Development 4.8
Projected Calls Generated Yearly by ALL Proposed (Pipeline) Developments 636.8
Projected Call Load In Immediate Service Area After Proposed Developments 4,165
Projected Call Load Increase in Immediate Service Area by Proposed Developments 18.2 %
Drive And Response Times
Response Zone Urban
Road Miles from Closest Fire Station 3.31 mi
Estimated Response Time for First Unit on Scene2
The CFEMS goal is a 7-minute or less response time for priority 1 incidents: 1:30 ECC processing + 1:30
FF Turnout + 4:00 travel time.
7:01 min
Supplemental Analysis
Budget & Management
Community Enhancement
Environmental Engineering
Fire & Emergency Medical Services
Page 100 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 8 of 24
Estimated Travel Time from Closest Fire Station1
The CFEMS goal is a 4-minute or less travel time from the closest CFEMS station for priority 1 incidents 4:01 min
Estimated Travel Time for an Effective Response Force2 < 3,000 sq/ft
An Effective Response Force is the ability to get the minimum number of firefighters on scene of a
structure fire within 8 minutes’ travel time to perform all critical tasks required.
6:32 min
Estimated Travel Time for an Effective Response Force2 > 3,000 sq/ft
An Effective Response Force is the ability to get the minimum number of firefighters on scene of a large
structure fire within 8 minutes’ travel time to perform all critical tasks required.
9:28 min
Planned Capital Facility Improvements
Five Forks Station : New facility in the vicinity of Courthouse Road and Route 288. Addresses
coverage gaps and demand issues in the area of 288 and Courthouse Rd. Property identified and
acquired. This new facility will be constructed on a site previously purchased and rezoned at the
intersection of Courthouse Road and Newby’s Bridge Road. The station was approved by voters as
part of a 2004 bond referendum but has not yet been constructed. Chesterfield Fire & Emergency
Management Services (CFEMS) plans to staff an engine company, truck company, and transport unit
at the future new station and relocate the Shift Commander and Tactical Safety Officer to the station
due to its central geographic location in the county near the intersection of Courthouse Road and
State Route 288. The proximity to two (2) major transportation arterials allows for substantial
improvement in 8 -minute drive time coverage that would allow CFEMS to improve Effective
Response Force (ERF) performance standards for nearly 5,000 additional addresses. This new facility
will also improve ERF performance along the Route 10 corridor north and south of State Route 288,
where considerable multi-family and mixed-use development is planned and approved.
Additional Information
The closest fire hydrant to this project is located at the corner of Clay Ridge Dr and Parrish Creek,
approximately .7 miles or roughly 3,700 ft away. The fire department will have to use multiple engine
companies to establish a water supply or deploy tanker shuttle operations which could delay the
establishment of an adequate and effective water supply plan.
If speed calming measures are included in the design of interior streets, these must be reviewed and
accepted by the Fire Department in coordination with CDOT. Certain speed calming measures may
increase Fire & EMS response times.
*Additional information relative to Fire & Life Safety’s Mission and Service Profile, Community Fire
Protection Capabilities Assessment, and Response Time Goals can be found in the Appendix.
1 Drive-time estimates are exclusive of potential delays due to weather, traffic, or blockage of response routes.
2 Estimates assume response units and personnel are in the station and available to respond at the time of an incident.
Nearby Facilities - LaPrade Library (5.3 miles) and Clover Hill Library (5.4 miles)
1. While all county libraries could be potentially impacted by the proposed development, the LaPrade Library and
the Clover Hill Library are the closest library facilities to the Property.
2. The Public Facilities Plan suggests the Clover Hill library should be expanded/replaced or a new facility shall be
constructed in the general vicinity at or near current site. Land for expansion of this facility has been acquired.
Libraries
Page 101 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 9 of 24
No comment on this request.
Division Beat District
Swift Creek 33 Matoaca
Additional Information
The proposed development is projected to generate an additional nineteen (19) Chesterfield
County Police Department calls for service, annually.
This application is for a development containing eighteen (18) residential lots. The total potential student yield for this
development is projected to be eight (8) to nine (9) students at buildout.
Membership and Capacity Zoning Case: 25SN1238
Current
Enrollment
(09-30-
2025)
Program
Capacity
(1)
Program
Capacity
Percentage
Proposed
Number of
Units
Housing
Type
SGF 2025 (2) Anticipated Student Yield Range
School
Specific
Countywide
Average
School
Specific
Countywide
Average
Thelma
Crenshaw
Elementary
698 752 93%
18 Single
Family 0.18 0.20 3.00 4.00
Multi-
Family - - - -
Condo - - - -
Townhouse - - - -
18 3 4
Bailey Bridge
Middle 1,272 1,499 85%
18 Single
Family 0.10 0.10 2.00 2.00
- Multi-
Family - - - -
- Condo - - - -
- Townhouse - - - -
18 2 2
Manchester
High 2,121 2,178 97%
18 Single
Family 0.14 0.14 3.00 3.00
- Multi-
Family - - - -
- Condo - - - -
- Townhouse - - - -
18 3 3
Notes:
(1) Program capacity is the maximum number of students the building can accommodate based on the Virginia Department of Education Standards
of Quality and the current school programming that may adjust the number of rooms used for core or grade-level classrooms in the overall
building design capacity.
(2) Student Generation Factor is the actual total number of students by grade level divided by the actual total number of housing units by housing
type. Based upon the average number of students per townhome dwelling unit for each of the school attendance zones where the proposal is
located. Updated annually based upon September 30 attendance.
Parks & Recreation
Police
Schools
Page 102 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 10 of 24
School Capacity Analysis
Thelma Crenshaw Elementary: Current program capacity at Thelma Crenshaw Elementary is at ninety-three (93)
percent. While the total potential yield from this case could range from three (3) to four (4) elementary students at full
build out, the number of potential students generated on an annual basis will change incrementally while this
development is under construction. This school is forecasting to be between 85.4 and 85.7 percent of program capacity
by 2030.
Bailey Bridge Middle: Current program capacity at Bailey Bridge Middle is at eighty-five (85) percent. While the total
potential yield from this case could range up to two (2) middle school students at full build out, the number of potential
students generated on an annual basis will change incrementally while this development is under construction. This
school is forecasting to be between 95.2 and 96.8 percent of program capacity by 2030.
Manchester High: Current program capacity at Manchester High is at ninety-seven (97) percent. While the total
potential yield from this case could range up to three (3) high school students at full build out, the number of potential
students generated on an annual basis will change incrementally while this development is under construction. This
school is forecasting to be between 96.0 and 96.5 percent of program capacity by 2030.
Additional information on CCPS Mission and Capital Improvements can be found in the Appendix.
The applicant has proffered a maximum density of 18 dwelling units. Applying trip generation for a single-family
detached dwelling unit, the development could generate approximately 170 average daily trips (ITE 12th Edition). The
Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide transportation needs that are
expected to mitigate traffic impacts of future growth. The anticipated traffic impact of the proposal has been evaluated,
and recommendations are detailed in the chart below. Traffic impacts of this request will be addressed through cash
payments and road improvements.
Recommendations Applicant’s
Proposal
Internal Sidewalks:
Virginia Department of Transportation (VDOT) standard sidewalk shall be provided along one side of all
roads, unless otherwise approved by the Planning and Transportation Departments or as required by
VDOT for state acceptance.
Proffered
Condition 4
Road Cash Proffer Policy (“Policy”):
An applicant may choose to address the development’s impacts on the county’s road transportation
network through dedication of property, construction of road improvements, or a cash proffer . In
accordance with the Policy, the traffic impact of the proposed development, located within Traffic
Shed 12, could be valued at $169,200 (18 dwelling units x $9,400). The applicant has proffered to
make payments of $9,400 for each dwelling unit at time of certificate of occupancy.
Proffered
Condition 5
Road Improvement – Prior to state acceptance of the proposed road:
Provide full width mill and overlay with surface asphalt of Cedar Springs Road from the P roperty’s
frontage to the Claypoint Road intersection (approximately 1,900 feet).
Proffered
Condition 6
Advisory – To be addressed at time of plans review:
• VDOT standard cul-de-sac shall be provided at the terminus of proposed road.
• Dedication of twenty-five (25)-foot of right-of-way, measured from the centerline of Cedar Spring Road
(local road), shall be provided in accordance with the Subdivision Ordinance.
• Provide 200-foot limited access setback along the Property’s frontage to Route 288 in accordance with
the Zoning Ordinance (shown on the conceptual plan).
Plans Review
(Advisory)
Transportation - County Department of Transportation
Page 103 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 11 of 24
The Virginia Department of Transportation (VDOT) has reviewed Case 25SN1238 for a rezoning from Agricultural (A) to
Semi-Rural Residential (SR) to permit a residential community with up to eighteen (18) single-family dwellings. The
Conceptual Plan (Exhibit A) shows a proposed eighteen (18) lot subdivision with a new proposed public local road off
Cedar Springs Road and a temporary cul-de-sac easement.
Any access to VDOT-maintained rights-of-way (ROWs) shall be in accordance with the requirements of the VDOT Road
Design Manual for the functional classification and design speed of the road. Any proposed access points that do not
meet the minimum spacing criteria for VDOT’s Access Management Policy will require an exception to be approved by
VDOT in order to permit and construct access. Any proposed commercial entrance shall be designed in accordance with
the Commercial Entrance Design Criteria per Appendix F of the Road Design Manual. During the plan review process,
VDOT will require trip generations, turn lane warrant analysis, and queuing analysis based on the proposed site
improvements. Any proposed roadway widening widths will need to match existing lane widths.
All proposed subdivision streets to be state-maintained must comply with all requirements of the 2011 Secondary Street
Acceptance Requirements (SSAR) Regulation, such as roadway width (with consideration for on-street parking and traffic
volume), pedestrian accommodations, and public benefits. The proposed development should follow the requirements
of Appendix B(1) of the VDOT Road Design Manual.
1. Use of public water and wastewater is not required in the Semi-Rural Neighborhood – Base Option.
2. The Applicant is proposing to use private wells and septic fields to serve the proposed development.
3. Public water and wastewater are not abutting the Property, therefore connection is not required under the
Utility Ordinance 18-60.
a. A public wastewater force main is located parallel to 288 along the northern property boundary however
connection to this line is not allowed.
b. Public water is approximately 3,500’ away on the opposite side of 288.
c. Public wastewater is approximately 100 feet to the west on the opposite side of Swift Creek. Due to
topography, this is not a viable option.
4. The Applicant has supplied Proffered Condition 7:
a. Dedication of sixteen (16) feet permanent water and ten (10) foot temporary construction easement along
the Property’s frontage of Cedar Springs Road in conjunction with the first site plan submittal.
b. Easement access shall be preserved to access the existing wastewater easement located along the southern
boundary of the Route 288 right-of-way.
5. The Utilities Department supports this request.
Transportation - Virginia Department of Transportation
Utilities – Water and Wastewater
Page 104 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 12 of 24
Page 105 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 13 of 24
Community Meetings
1/22/2026 – Discussion Topics:
1. Impact on wells serving existing homes
2. Hydraulic analysis for potential impacts on wells
3. Project phasing
4. Traffic impact on Claypoint Road
5. Construction traffic
6. Concerns over pedestrian easement and trespassing
7. Stormwater runoff
6/1/2026 – Discussion Topics:
1. Questions on hydrogeologic studies
2. Lack of well contractors and potential conflict of interest
3. Size of homes
4. Availability of water and sewer
5. Projected timeline
Community Engagement & Public Hearings
Page 106 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 14 of 24
The property owners and applicant in this rezoning case, pursuant to Section 15.2-2298 of the Code of Virginia (1950 as
amended) and the Zoning Ordinance of Chesterfield County (the “Zoning Ordinance”), for themselves and their
successors or assigns, proffer that the property under consideration (the “Property”) will be developed according to the
following proffers if, and only if, the rezoning request submitted herewith is granted with only those conditions agreed
to by the owners and applicant. In the event this request is denied or approved with conditions not agreed to by the
owners and applicant, the proffer shall immediately be null and void and of no further force or effect.
These Proffered Conditions include two (2) exhibits attached hereto:
Exhibit A: Swift Creek Conceptual Plan, prepared by Timmons Group and last revised June 1, 2026 (“Conceptual Plan”)
Exhibit B: Residential Elevation Concept, prepared by Main Street Homes and dated August 22, 2026 (“Conceptual
Elevations”)
1. Conceptual Plan. The Property shall be developed in general conformance with the Conceptual Plan. The
Conceptual Plan is conceptual in nature and may vary based on the final approved subdivision plans or site plan,
as applicable, depending on the final soil studies, RPA lines, road design, lot locations, lot line locations, amenity
locations, VDOT requirements, BMP design and location, pedestrian way design and location, and other design
or engineering reasons. Any substantive changes that do not relate to the prior sentence shall be approved by
the Planning Commission at the time of plans review. In the event of any conflict between information shown on
the Conceptual Plan and these Proffered Conditions, these Proffered Conditions shall control. (P)
2. Residential Density. The total number of residential dwelling units on the Property shall not exceed 18 units. (P)
3. Environmental Engineering.
a. Super Silt Fence, or an alternative as approved by the Department of Environmental Engineering, shall be
provided as a perimeter control in locations where standard silt fence would have been required.
b. Anionic PAM, Flexible Growth Medium and/or a County-approved equivalent shall be applied to denuded
areas (areas that have been cleared of vegetative cover) during construction and at final stabilization in the
locations shown on plans approved by Environmental Engineering at the time of plans review.
c. The maximum post-development discharge rate for the 100-year storm shall be based on the maximum
capacity of the existing facilities downstream, and shall not increase the recorded and /or established 100-
year backwater and /or floodplain. On-Site detention of the post-development 100-year discharge rate to
below the pre-development 100-year discharge rate may be provided to satisfy this requirement. (EE)
4. Internal Sidewalks. Sidewalks shall be provided on one side of all roads within dedicated right-of-way, unless
otherwise approved by the Planning and Transportation Departments or as required by VDOT for road
acceptance. (P and T)
5. Road Cash Proffers. The applicant/sub-divider, or assignee(s) (“Developer”) shall pay $9,400 for each dwelling
unit to Chesterfield County for road improvements within the service district for the Property (“Road Cash
Proffer Payment”). Each Road Cash Proffer Payment shall be made prior to the issuance of a certificate of
occupancy for a dwelling unit unless state law modifies the timing of the payment. Should Chesterfield County
impose impact fees at any time during the life of the development that are applicable to the Property, the
amount paid in cash proffers shall be in lieu of or credited toward such fees in a manner determined by
Chesterfield County. (T)
Proffered Conditions (8/6/2026)
Page 107 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 15 of 24
6. Road Improvement. Prior to state acceptance of the proposed road on the Property, the owner/developer shall
complete a full width mill and overlay with surface asphalt of Cedar Springs Road from the property’s frontage
to the Cedar Springs Road/Claypoint Road intersection (approximately 1,900 feet), with any such modifications
approved by the Transportation Department and VDOT (“Improvement”). If the Improvement is completed by
others, as determined by the Transportation Department and/or VDOT, then the owner/developer shall be
relieved of the obligation to provide the Improvement. (T)
7. Utility Easement Dedication.
a. Dedication of 16’ permanent water and 10’ temporary construction easement along the property frontage
of Cedar Springs Road in conjunction with the first site plan submittal.
b. Easement access shall be preserved to access the existing wastewater easement located along the southern
boundary of the 288 right-of-way. (U)
8. Foundations. There shall be a minimum vertical height of eighteen (18) inches of brick, stone or stone veneer
above grade utilized on slab-on-grade foundations on all front, side, and rear elevations. All foundations shall be
faced entirely of brick, brick veneer, stone, stone veneer, cultured stone, and/or other masonry materials.
Synthetic or natural stucco foundations may be permitted for facades constructed entirely of stucco. Except (i)
for units where the grade drops along the façade foundation this required masonry may step down at eighteen
inch (18”) intervals for a maximum of two steps, and (ii) for units with a walkout basement siding may continue
to the ground level of a walkout basement (aa) if there is a window or door that shows the presence of a
basement floor or (bb) if there is a first floor deck. (P)
9. Planting Beds. Foundation planting beds shall be provided along the front façades of dwelling units. Foundation
planting beds shall be a minimum of four (4) feet wide as measured from the foundation. Foundation planting
beds that extend a minimum of one third (1/3) of the length of the side elevation (as measured from the front
corner of the unit) are also required on building side elevations that are adjacent to public streets. Planting beds
shall be defined with a trenched edge or suitable landscape edging material. Planting beds shall include medium
shrubs spaced a maximum of four (4) feet apart. Corners shall be visually softened with vertical accent shrubs (2-
4’ in height) or small evergreen trees (5-7’ in height) at the time of planting. (P)
10. Driveways/Front Walks.
a. All private driveways shall be hardscaped (concrete, asphalt, pavers or other material approved by the
Planning Director at the time of plans review).
b. Front walks shall be provided from the driveway or sidewalk to the front entrance of a dwelling. All front
walks shall be a minimum of three (3) feet in width and hardscaped (concrete, asphalt, pavers or other
material approved by the Planning Director at the time of plans review).
c. One (1) lamp post shall be provided in the front yard of each dwelling unit. The design of such lamp posts
shall be consistent throughout the Property. (P)
11. Porches and Stoops. Front stoops and porches shall be constructed with continuous foundation walls or
masonry piers to match the foundation of the home. Extended front porches shall be a minimum of five (5) feet
deep. Handrails and railings, when required by the building code, shall be finished painted wood, vinyl rails or
metal rail systems with vertical pickets, sawn balusters, or other products of equal quality. Pickets shall be
supported on top and bottom rails that span between columns. (P)
12. Fireplaces, Chimneys and Flues. If provided, the following shall be required:
a. Masonry fireplace chimney chases shall be constructed of brick or stone. The width and depth of chimneys
shall be appropriately sized in portion to the size and height of the unit. (P)
Page 108 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 16 of 24
13. Heating, Ventilation and Air Conditioning (HVAC) Units and Generators. HVAC units and generators installed as
fixtures shall be screened initially from view of roads by landscaping or low maintenance material, as approved
by the Planning Department. (P)
14. Garage Doors. Any front-loaded garage door shall use an upgraded garage door. An upgraded garage door is any
door that meets one of the following two (2) requirements:
a. A minimum of three (3) enhanced features are provided on the garage door. Enhanced features shall include
windows, raised panels, decorative panels, arches, hinge straps or other architectural features on the
exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs arches, columns, keystones,
eyebrows, etc.) Flat panel garage doors shall be prohibited.
b. The garage door provides an enhanced architectural style that relates to the architecture of the dwelling the
garage serves. Enhanced architectural style shall mean the use of color, panels and/or windows to reflect an
architectural style such as contemporary, modern, modern farmhouse, mediterranean, colonial, and tudor.
The architectural style may be evidenced by manufacturer printed material. (P)
15. Architecture. Development of single family detached dwellings shall be in general conformance with the
illustrative elevations in Exhibit B or another architectural appearance approved by the Planning Director at the
time of plans review. Subsequent to plans approval, the owner may also request approval of another
architectural appearance by the Planning Director. The illustrative elevations are conceptual in nature and may
vary at the time of plans review. For example, the location of materials, types of material, use of stoops, use of
covered porches, and other architectural detailing may change and may vary from home to home. (P)
16. Variation in Front Elevations. Buildings with the same front elevation may not be located next to each other or
across a street from each other. Variation in the front elevation may not be achieved by simply mirroring the
façade, but may be accomplished by providing at least three (3) of the following architectural changes:
a. Adding masonry elements above the masonry required for the foundation.
b. Changing the location of roof type, roof line, front facing gable(s) and/or dormers.
c. Changing the style of roof type, roof line, front facing gable(s) and/or dormers.
d. Providing varied siding application using horizontal siding, shake siding or board and batten siding.
e. Providing varied color application.
f. Adding or removing a porch.
g. Adding or removing a covered stoop.
h. Adding projections such as bay/box windows, second floor balconies, or accent roofs.
i. Adding a fourth (4th) enhanced feature to a garage door.
j. Any other element of architectural variation as approved by the Director of Planning. (P)
17. Exterior Materials.
a. Acceptable siding materials include brick, stone, masonry, fiber cement siding, engineered wood siding or
high-grade vinyl (a minimum of .044” nominal thickness as evidenced by manufacturer’s printed literature).
Dutch lap, plywood, and metal siding are not permitted. Other materials may be used for parapets, cornices,
surrounds, soffits, trim, architectural decorations, and design elements.
b. Slanted roofing material shall be dimensional architectural shingles with a minimum thirty (30) year
warranty or standing seam metal. (P)
18. Water Wells. All wells drilled to provide domestic water supply to homes within the proposed development shall
be drilled to a minimum of 200 feet in depth. (P)
Page 109 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 17 of 24
Conceptual Plan – Exhibit A
Page 110 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 18 of 24
Conceptual Elevations – Exhibit B
Page 111 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 19 of 24
Page 112 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 20 of 24
Page 113 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 21 of 24
Applicant
• Applicant’s Agent:
Brady Deal (540-905-3415)
• Applicant’s Contact:
Greg Rogers (804-200-6580)
District Planning Commissioner
• Christopher Chapman
chapmanch@chesterfield.gov
Staff
• Planning Department Case Manager: Richard Saunders (804-796-7192) saundersri@chesterfield.gov
• Budget & Management: David Oakley (804-706-2586) oakleyd@chesterfield.gov
• Community Enhancement: Brian Chamberlain (804-748-1541) chamberlainb@chesterfield.gov
• Environmental Engineering: Douglas Miles (804 -768-7797) milesd@chesterfield.gov
• Fire & Emergency Medical Services: Christopher Harding (804-971-0399)
hardingc@chesterfield.gov
• Libraries: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov
• Parks & Recreation: Laura Baker (804-717-6354) bakerla@chesterfield.gov
• Police: Jim Eicher (804-318-8693) eicherj@chesterfield.gov
• Schools: David Oakley (804-706-2586) oakleyd@chesterfield.gov
• Transportation - County Department of Transportation: Steve Adams (804-751-4461)
adamsst@chesterfield.gov
• Transportation - Virginia Department of Transportation: Dustin Dunnagan (804-674-2384)
dustin.dunnagan@vdot.virginia.gov
• Utilities: Alan Harrison (804-796-7126) harrisonl@chesterfield.gov
Case Contacts
Page 114 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 22 of 24
Mission & Service Profile
The mission of Chesterfield Fire and Emergency Medical Services (CFEMS) is to protect life, property and the
environment. This requires a comprehensive portfolio of services aimed at preventing fires, mitigating the impact of
fires and disasters on the community, and providing a timely and effective response when fires, medical and other
emergencies occur. Community risks, population growth and demographic changes, service demands, and response
times are reviewed annually and the need for additional Fire & EMS operating and capital resources in support of the
department’s mission is evaluated during the county’s annual budget and 5-year Capital Improvement Plan (CIP)
processes.
Community Fire Protection Capabilities Assessment
Chesterfield Fire and EMS participates in the Insurance Services Office (ISO) Public Protection Classification (PPC)
program, which rates a community’s fire protection capabilities in accordance with the Fire Suppression Rating Schedule
(FSRS). Using the FSRS, the ISO performs a comprehensive evaluation of a community’s fire department, water supply,
emergency communications and community risk reduction efforts. The resulting score establishes a PPC rating from 1 to
10, with Class 1 being the best possible rating. Many insurance carriers reference a community’s PPC rating in
establishing insurance premiums. Generally, communities with a Class 1 rating enjoy lower insurance premiums than
those communities with a Class 10 rating. Chesterfield County has a current community classification of 2/2Y, however
some portions are classified as 10 or 10W based on the parameters indicated below;
Class 2 - within 5 miles of a fire station and within 1,000 feet of a fire hydrant.
Class 2Y – within 5 miles of a fire station but not within 1,000 feet of a fire hydrant.
Class 10W – within 5-7 miles of a fire station and within 1,000 feet of a fire hydrant.
Class 10 – outside of 5 miles of a fire station and not within 1,000 feet of a fire hydrant.
Appendix
Fire & Emergency Medical Services
Page 115 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 23 of 24
Response Time Goals (Urban/Rural Zones)
Urban Zone
Fire and EMS response goal is 7 minutes from receipt of call in the Emergency Communications Center (ECC) to arrival of
first responding unit. Fire and EMS facilities should be strategically located to provide 4 minutes or less travel time for
the first arriving engine company at a suppression incident, and 8 minutes or less travel time for deployment of an
Effective Firefighting Force (first alarm assignment) at a suppression incident.
Rural Zone
Fire and EMS response goal is 12 minutes from receipt of call in the Emergency Communications Center (ECC) to arrival
of first responding unit. Fire and EMS facilities should be strategically located to provide 9 minutes or less travel time for
the first arriving engine company at a suppression incident, and 13 minutes or less travel time for deployment of an
Effective Firefighting Force (first alarm assignment) at a suppression incident.
Page 116 of 218
Swift Creek Reserve Rezoning 25SN1238 Page 24 of 24
Mission
High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The
comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater
access, flexible designs and locations that better meet the needs of the communities in which they are located.
Capital Improvements
The School Board FY2026 approved five-year Capital Improvement Plan (CIP) continues to support the 2022 voter
approved bond referendum. The approved CIP will replace or renovate seven schools and construct five new schools to
add an additional capacity of approximately 8,500 seats countywide. The existing facilities that are part of the
replacement and renovation program are A.M. Davis Elementary (completed August 2025), Bensley Elementary (to open
August 2026), Grange Hall Elementary, Falling Creek Middle School (completed August 2024), Matoaca Middle,
Midlothian Middle, and Thomas Dale High. The five new schools include a Deep Creek Middle School (completed August
2025) and Deep Creek Elementary School (to open August 2026) near Westerleigh Parkway. A Western Area High School
will also open in 2027 near Duval Road. A new Dale District and an Old Hundred Area Elementary School are also in the
CIP. Information on the CIP and School Board approved construction projects can be found in the financial section of the
CCPS Adopted Budget for FY2026 or the County CIP Dashboard.
Schools
Page 117 of 218
25SN1238 – Matoaca
Rezone from Agricultural (A) to Semi-Rural Neighborhood (SR).
Swift Creek Reserve Rezoning
Case 25SN1238, in the Matoaca Magisterial District, Swift Creek Reserve Rezoning is a
request to rezone 37.2 acres to Semi-Rural Neighborhood. A single-family
development with up to eighteen (18) residential lots is proposed.
1
Page 118 of 218
25SN1238 – Overview
1. Rezone from A to SR, 18
single-family dwellings
proposed
2. Density = 0.48 DUA, Plan
supports 0.5 DUA or less
3. Minimum lot size of 2 acres
4. Staff recommends approval
Overview Slide.
2
Page 119 of 218
25SN1238 – Zoning Map
The subject property, outlined in red, consists of 37.2 acres, and is currently zoned
Agricultural (A). Properties to the east and south are also zoned Agricultural (A).
Properties to the north and west are zoned Suburban Community (SC).
3
Page 120 of 218
25SN1238 – Aerial & Land Use Plan Map
The subject property is outlined in white on the left image and in grey on the right. The
aerial image on the left shows that the site is currently undeveloped and primarily
wooded. The image on the right highlights the Land Use Plan designation for the
Property. The Comprehensive Plan designates the Property for Residential Agricultural,
which suggest the Property is appropriate for residential development at a maximum
density of 0.5 dwelling units per acre.
4
Page 121 of 218
25SN1238 – Conceptual Plan
A residential community consisting of a maximum of eighteen (18) single-family
dwellings is proposed as detailed in the Conceptual Plan shown in this slide and
proffered by the applicant (Proffered Condition 1). Single-family detached
dwellings located on individual lots are planned, with lot sizes ranging from 2.0
to 2.58 acres as conceptually shown on the Conceptual Plan. The development
would have one (1) entrance off of Cedar Springs Road. As required by the
Zoning Ordinance, a 200-foot sound setback is being provided within lots from
the Route 288 right-of-way. Clearing of trees would not be permitted within this
setback. The local road serving the subdivision would be stubbed to the
property to the south, with a temporary cul-de-sac easement being provided at
the road’s terminus.
5
Page 122 of 218
25SN1238 – Conceptual Elevations
Lot and project design standards have been proffered to include: internal
sidewalks on one side of the internal project road, front foundation planting
beds, hardscaped front walks and driveways, and screening of mechanical
equipment (Proffered Conditions 4, 9, 10 and 13). Design standards for
dwellings include masonry foundation treatment, treatment of porches, stoops,
garage doors and fireplaces, chimneys, and flues, conceptual elevations, as
shown in this slide, unit variation, and the use of high-quality siding and roofing
materials (Proffered Conditions 8, 11, 12, 14, 15, 16 and 17).
6
Page 123 of 218
25SN1238 – Recommendation
1. Staff- Approval
• Proposal conforms to Plan’s use and density
guidance
• High-quality, single-family housing proposal
Staff recommends approval of the request. The applicant proposes a single-family
detached residential development on large lots, consistent with the uses and
density supported by the Comprehensive Plan. The proffered design standards
will contribute to the creation of a well-designed, attractive, and vibrant
community.
7
Page 124 of 218
25SN1238 – Zoning Map
Extra slide.
8
Page 125 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 1 of 26
25SN1332 – The Reserve Rezoning &
Adjustments
Magisterial District – Matoaca
Agent – Anne Miller (804-707-7149)
CPC Public Hearing – August 18, 2026
Time Remaining
100 Days
Case Manager
Harold Ellis
(804-768-7592)
Request
Rezoning &
Adjustments to Ordinance Requirements
A single-family development with up to 32 dwellings is
proposed.
Staff Recommendation
Approval
The Property
16200 Beach Road
Site Size
19.52 Acres
Comprehensive Plan –
Land Use Designation
Residential Neighborhood 2
Plan Area
County Wide Plan
Figure 1: Aerial of Request Area – Click Image for Link to GIS
Figure 2: Area Map of Request & Land Use Plan Map
Rezoning from Agricultural (A) District to the Suburban Community (SC) District with an adjustment to ordinance
requirements.
A residential development is proposed consisting of up to thirty-two (32) single-family dwellings. The minimum lot area
will be 10,000 square feet and the density of the development is 1.64 dwelling units per acre. The applicant proposes a
buffer adjacent to the existing Harpers Mill subdivision, as well as a pedestrian trail connecting to a required shared use
path along Beach Road. The applicant requests an adjustment to ordinance requirements to reduce the width of the
required buffer along Beach Road to assist in accommodating a County utility line project.
Staff Note: This request is subject to the procedural and development regulations provided
in Chapter 19.2 of the Zoning Ordinance.
Summary of Proposal
Page 126 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 2 of 26
STAFF - APPROVAL
The proposed lot sizes are consistent with adjacent and nearby properties and the development provides quality design
and architecture resulting in an attractive and harmonious community. The Comprehensive Plan’s land use
recommendation for the Property is for Residential Neighborhood 2 uses, which supports the proposed single-family
residential subdivision. The proposal’s overall residential density of 1.64 dwelling unit per acre falls below the Plan’s
recommended residential density of 2.0 dwelling unit per acre or less.
NOTES FOR THE PLANNING COMMISSION AND BOARD OF SUPERVISORS
1. The only condition that may be imposed is a buffer condition. The property owner may proffer conditions.
2. Proffered conditions, a conceptual plan, and conceptual elevations have been submitted by the applicant.
Recommendation
Page 127 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 3 of 26
Summary of Proposal .............................................................................................................................................................. 1
Recommendations .................................................................................................................................................................. 2
Table of Contents .................................................................................................................................................................... 3
Planning................................................................................................................................................................................... 4
Current Zoning Map ................................................................................................................................................................ 7
Supplemental Analysis ............................................................................................................................................................ 8
Community Enhancement .................................................................................................................................................. 8
Environmental Engineering ................................................................................................................................................. 8
Fire & Emergency Medical Services .................................................................................................................................... 8
Libraries ............................................................................................................................................................................... 9
Parks & Recreation .............................................................................................................................................................. 9
Police ................................................................................................................................................................................... 9
Schools .............................................................................................................................................................................. 10
Transportation - County Department of Transportation .................................................................................................. 12
Transportation - Virginia Department of Transportation ................................................................................................. 13
Utilities – Water and Wastewater .................................................................................................................................... 13
Community Engagement ...................................................................................................................................................... 15
Proffered Conditions (8/3/2026) .......................................................................................................................................... 16
Justification for Adjustment to Ordinance Requirements .................................................................................................... 20
Concept Plan – Exhibit A ....................................................................................................................................................... 21
Conceptual Elevations – Exhibit B ......................................................................................................................................... 22
Case Contacts ........................................................................................................................................................................ 23
Appendix ............................................................................................................................................................................... 24
Fire & Emergency Medical Services .................................................................................................................................. 24
Schools .............................................................................................................................................................................. 26
Table of Contents
Page 128 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 4 of 26
Comprehensive Plan – Land Use Plan Designation
The Comprehensive Plan designates the Property for Residential Neighborhood 2, which suggests the Property is
appropriate for residential development at a density of 2.0 dwelling units per acre or less. Appropriate land uses include
single-family dwellings; neighborhood-serving, low-intensity commercial uses; and religious institutions and government
buildings.
Proposal
The applicant is requesting rezoning from
the Agricultural (A) District to the
Suburban Community (SC) District with
adjustments to ordinance requirements to
permit a thirty-two (32) lot residential
development (Exhibit A). The application
acreage is 19.52 acres of a larger 25.75
acre parcel. The remaining parcel acreage
is not a part of the rezoning case and will
retain its current Agricultural (A) zoning.
The proposed density is 1.64 dwelling units
per acre.
The applicant is proffering lot sizes with a
minimum area of 10,000 square feet. As
illustrated in the Concept Plan (Exhibit A),
and Figure 3, primary access to the site is
provided by a single access point from
Beach Road.
The applicant proposes a thirty-five
(35) foot buffer adjacent to the existing
Harpers Mill subdivision, as well as a
pedestrian trail connecting to a required shared use path along Beach Road. In addition to the buffer, open space
illustrated behind Lots 8 and 9 will further buffer the site from Harpers Mill and preserves existing vegetation in those
areas.
Requested adjustment to ordinance requirements include a reduced required buffer along Beach Road to assist in
accommodating a County utility line project.
Planning
Figure 3: Excerpt from Conceptual Plan
Figure 3: Excerpt from Conceptual Plan
Page 129 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 5 of 26
Design
High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods
that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance
to promote the health, safety, convenience and general welfare of the public includes the creation of convenient,
attractive and harmonious communities, protection against overcrowding of land, and protection of the natural
environment. As such, developments that promote unique, viable and long-lasting places and enhance the community
are encouraged.
The following provides an overview of the design standards offered as part of this request (Proffered Conditions 8-22):
Community Design
• Conceptual Plan (Exhibit A)
• Amenity and Open space
• Anti-monotony requirements
• Buffering adjacent to existing residential
• Entry Monument
• Cluster mailbox and unified lot lamp post
lighting
Building & Lot Design
• Conceptual building elevations (Exhibit B)
• Siding Materials: Acceptable siding materials include brick, stone, masonry, fiber cement siding (such as
HardiPlank, HardieShingle, and HardieTrim), engineered wood siding (such as LP SmartSiding), or premium
quality vinyl.
• Masonry Requirement: At least fifty (50) percent of dwelling units constructed shall have brick, stone or masonry
fronts that cover a minimum of twenty (20) percent of the front façade (which façade shall exclude gables,
windows, trim, and doors).
• Masonry Foundations:
o Slabs. All exposed portions of the foundation, except for exposed piers supporting front porches of each
new dwelling unit, shall be faced with brick or stone veneer a minimum of eighteen (18) inches above
grade on front foundations; and twelve (18) inches on sides and rear foundations.
o All other foundations. All other foundations shall be faced entirely of brick, brick veneer, stone, stone
veneer, cultured stone, and/or other masonry materials; except for units where the grade drops along
the façade foundation this required masonry may step down at twelve (18) inch intervals limited to two
step downs
• Roof Material: Roofing material for sloped and flat roofs is required to be dimensional architectural shingles,
standing seam metal, or another suitable material with a minimum thirty (30) year warranty.
• Heating, Ventilation and Air Conditioning (HVAC) Units and Whole House Generators: Units shall initially be
screened from view by landscaping or low maintenance material.
• Garages: A minimum of three (3) enhanced features shall be provided on garage doors, as well as decorative
exterior lighting.
• Foundation Landscaping: Foundation planting is required along the entire front and corner side façade(s) of all
dwelling units.
Page 130 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 6 of 26
Adjustments
The applicant is requesting an adjustment to an ordinance requirement, highlighted below. The applicant has provided
justification and mitigation to account for the adjustment.
Adjustment 1: 19.2-35. B.3 & Table 19.2-35.3 Buffers Adjacent to Roads for Subdivisions.
The applicant requests a seventy-five (75) foot reduction to the required 100-foot wide buffer along Beach Road, an
arterial roadway. The Property is located within the Upper Swift Creek Special Buffer Area, which requires a 100-foot
wide buffer along arterial roadways.
This adjustment is being requested as the Utilities Department is requesting that the owner grant easements and install
improvements for the benefit of the County’s utility system so that the system may serve other properties. This
adjustment is being mitigated with requisite landscaping (being permitted within the easements), through the provision
of amenity space for the development, and with thirty-five (35) foot buffer along the east and north property lines, as
described in Proffered Conditions 19 and 20.
Staff supports the adjustment. The applicant has indicated the adjustment is warranted, sufficient, provide appropriate
mitigation, and will enhance the proposal compared to what would be required with Ordinance requirements. Further,
the reduction in buffer will allow the County utility project to continue which will serve other County projects and
properties.
Findings
The proposed lot sizes are consistent with adjacent and nearby properties and the proposed density and land use is in
compliance with the Comprehensive Plan’s land use plan designation. Additionally, a thirty-five (35) foot buffer is being
proposed along the north and east sides of the development adjacent to Harpers Mill. Further, with the proffered
conditions proposed, the development provides quality design and architecture resulting in an attractive and
harmonious community.
Page 131 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 7 of 26
Current Zoning Map
Page 132 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 8 of 26
No comment on this request.
The Property is located within the Appomattox Watershed and Resource Protection Area Delineation (RPAD)-1131
issued on May 5, 2022, did not confirm any Resource Protection Area (RPA) on the Property. Increased stormwater
runoff from the development may increase floodplain limits on downstream properties. Impervious areas created from
the development of the Property shall not sheet-flow through adjacent properties to the north or east in Harpers Mill
Southwest Section 2 subdivision.
a. The applicant has offered Proffered Condition 6 a. and b. to address these concerns.
Service Area
The Winterpock Fire Station, Company Number 19
Community Fire Protection Capabilities Assessment*
Insurance Service Office (ISO) Public Protection Classification (PPC)
An ISO rating of 10 or 10W places the development within a service area that may have longer Fire and
EMS response times, higher risks of increased fire damage, and homeowners may have limited
insurance carrier choices with higher insurance premiums.
Class 2
Anticipated Impacts On Fire & EMS
Call Load in Immediate Service Area During Previous Fiscal Year 1,342
Projected Calls Generated Yearly by This Proposed Development 5.5
Projected Calls Generated Yearly by ALL Proposed (Pipeline) Developments 388.2
Projected Call Load In Immediate Service Area After Proposed Developments 1,735
Projected Call Load Increase in Immediate Service Area by Proposed Developments 29.3%
Drive And Response Times
Response Zone Rural
Road Miles from Closest Fire Station 2.9 mi
Estimated Response Time for First Unit on Scene2
The CFEMS goal is a 12-minute or less response time for priority 1 incidents: 1:30 ECC processing + 1:30
FF Turnout + 9:00 travel time.
6:38 min
Estimated Travel Time from Closest Fire Station1
The CFEMS goal is a 9-minute or less travel time from the closest CFEMS station for priority 1 incidents 3:38 min
Estimated Travel Time for an Effective Response Force2 < 3,000 sq/ft
An Effective Response Force is the ability to get the minimum number of firefighters on scene of a
structure fire within 13 minutes’ travel time to perform all critical tasks required
6:22 min
Estimated Travel Time for an Effective Response Force2 > 3,000 sq/ft
An Effective Response Force is the ability to get the minimum number of firefighters on scene of a
large structure fire within 13 minutes’ travel time to perform all critical tasks required.
9:10 min
Supplemental Analysis
Community Enhancement
Environmental Engineering
Fire & Emergency Medical Services
Page 133 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 9 of 26
Planned Capital Facility Improvements
There are no planned capital facility improvements for this fire district at this time.
Additional Information
When the property is developed, the number of hydrants, quantity of water needed for fire protection,
and access requirements will be evaluated during the plans review process. If speed calming measures
are included in the design of interior streets, these must be reviewed and accepted by the Fire
Department in coordination with CDOT. Certain speed calming measures may increase Fire & EMS
response times.
*Additional information relative to Fire & Life Safety’s Mission and Service Profile, Community Fire
Protection Capabilities Assessment, and Response Time Goals can be found in the Appendix.
1 Drive-time estimates are exclusive of potential delays due to weather, traffic, or blockage of response routes.
2 Estimates assume response units and personnel are in the station and available to respond at the time of an incident .
Nearby Facility – Clover Hill Library (6.2 miles)
1. While all county libraries could be potentially impacted by the proposed development, the C lover Hill Library is
the closest library facility to the Property.
2. Public Facilities Plan suggests the Clover Hill Library should be expanded/replaced or a new facility at or near current
site. Land for expansion or replacement of this facility or new facility has been acquired.
No comment on this request.
Division Beat District
Swift Creek 38 Matoaca
Additional Information
The development is projected to generate an additional sixteen (16) Chesterfield County Police
Department calls for service, annually.
The applicant has included a CCPD-recommended CBU illumination proffer (Proffered Condition
22).
Libraries
Parks & Recreation
Police
Page 134 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 10 of 26
This application is for a development containing thirty-two (32) residential lots. The total potential student yield for this
development ranges from thirteen (13) to fifteen (15) students at buildout.
Membership and Capacity Zoning Case: 25SN1332
Current
Enrollment
(09-30-
2025)
Program
Capacity
(1)
Program
Capacity
Percentage
Proposed
Number
of Units
Housing Type
SGF 2025 (2) Anticipated Student Yield Range
School
Specific
Countywide
Average
School
Specific
Countywide
Average
Grange Hall
Elementary 702 811 87%
32 Single
Family 0.20 0.20 6.00 6.00
Multi-
Family - - - -
Condo - - - -
Townhouse - - - -
32 6 6
Bailey
Bridge
Middle
1,272 1,499 85%
32 Single
Family 0.10 0.10 3.00 3.00
- Multi-
Family - - - -
- Condo - - - -
- Townhouse - - - -
32 3 3
Cosby High 2,489 1,987 125%
32 Single
Family 0.19 0.14 6.00 4.00
- Multi-
Family - - - -
- Condo - - - -
- Townhouse - - - -
32 6 4
Notes:
(1) Program capacity is the maximum number of students the building can accommodate based on the Virginia Department of Education
Standards of Quality and the current school programming that may adjust the number of rooms used for core or grade-level classrooms in the
overall building design capacity. Program capacity numbers may be higher than previous years due to more spaces being designated/quantified
for capacity uses. Updated annually by CCPS on September 30.
(2) Student Generation Factor is the actual total number of students by grade level divided by the actual total number of housing units by
housing type. Based upon the average number of students per townhome dwelling unit for each of the school attendance zones where the
proposal is located. Updated annually based upon September 30 attendance.
School Capacity Analysis
Grange Hall Elementary: Current program capacity at Grange Hall Elementary is eighty-seven (87) percent. While the total
potential yield from this case could range up to six (6) elementary students at full build out, the number of potential
students generated annually will change incrementally while this development is under construction. This school
is forecasting to be between 95 and 98.9 percent of program capacity by 2030. A Capital Improvement Project (CIP) is
planned within this school’s attendance zone and should provide additional capacity for this school facility as well as
nearby school facilities.
Schools
Page 135 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 11 of 26
Bailey Bridge Middle: Current program capacity at Bailey Bridge Middle is eighty-five (85) percent. While the total
potential yield from this case could range up to three (3) middle school students at full build out, the number of potential
students generated on an annual basis will change incrementally while this development is under construction. This school
is forecasting to be between 95.2 and 96.8 percent of program capacity by 2030.
Cosby High: Current program capacity at Cosby High is 125 percent. While the total potential yield from this case could
range up to four (4) to six (6) high school students at full build out, the number of potential students generated on an
annual basis will change incrementally while this development is under construction. This school is forecasting to be
between 145.1 and 147.6 percent of program capacity by 2030. West Ridge High School is currently under construction
and will open in August 2027. This will provide additional capacity and the opportunity to balance enrollment at the high
school level and provide relief to Cosby High.
Additional information on CCPS Mission and Capital Improvements can be found in the Appendix.
Page 136 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 12 of 26
The applicant has proffered a maximum density of thirty-two (32) dwelling units. Applying trip generation rates for a
single-family detached unit, development could generate approximately 300 average daily trips (ITE 12th Edition). The
Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide transportation needs that are
expected to mitigate traffic impacts of future growth. The anticipated traffic impact of the proposal has been evaluated,
and recommendations are detailed in the chart below. The traffic impact of this request will be addressed through road
improvements.
Recommendation Applicant’s
Proposal
Vehicular Access:
Limited to two (2) accesses to Beach Road (Major Arterial), which shall consist of one public road access
to serve the development and one access to serve county/utility facilities.
Proffered
Condition 3
Road Improvements (in conjunction with initial development):
• Widen/improve the north side of Beach Road to provide an eleven (11) foot wide travel lane, five (5)
foot wide paved shoulder, three (3) foot wide unpaved shoulder, and overlaying the full width of the
road for the property frontage for the zoning request (approximately 850 feet) and for the portion of
the property not part of this zoning request to the western property line (approximately 1,100 feet).
• Construction of left and right turn lanes along Beach Road into the approved public road access.
Proffered
Condition 4
Dedication:
Forty-five (45) feet of right-of-way on the north side of Beach Road, measured from the centerline of that
part of the road adjacent to the Property.
Proffered
Condition 5
Road Cash Proffer Policy:
An applicant may choose to address the development’s impacts on the county’s road transportation
network through dedication of property, construction of road improvements, or a cash proffer . In
accordance with the Policy, the traffic impact of the proposed development, located within Traffic
Shed 11, could be valued at $300,800 (32 single family dwelling units x $9,400).
The applicant has proffered to construct off -site road improvement (widen/improve north side of
Beach Road, approximately 1,100 feet) as noted above. Staff estimates cost of the off -site road
improvement is $979,000. It should be noted, however, that the actual cost to provide this
improvement could be more or less than this amount.
Proffered
Condition 4
Advisory – At time of plans review:
As required by the Zoning Ordinance, the development will be required to address the Bikeways and Trails
Plan by providing a VDOT standard shared use path along the rezoned portion of the property frontage
to Beach Road (shown on the conceptual plan).
Transportation - County Department of Transportation
Page 137 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 13 of 26
The Virginia Department of Transportation (VDOT) has reviewed Case 25SN1332 for a rezoning from Agricultural (A) to
Suburban Community (SC) to permit a residential community with up to thirty-two (32) single-family dwellings. The
Concept Plan (Exhibit A) shows a proposed thirty-two (32)-lot subdivision with a new proposed public local road
containing two cul-de-sacs off Beach Road, an area reserved for stormwater management, a pedestrian trail, a shared
use path, a forty-five (45)-foot right-of-way (ROW) dedication, a thirty (30)-foot utility easement, and a pedestrian
access easement.
Any access to VDOT-maintained right-of-way (ROW) shall be in accordance with the requirements of the VDOT Road
Design Manual for the functional classification and design speed of the road. Any proposed access points that do not
meet the minimum spacing criteria for VDOT’s Access Management policy will require an Exception to be approved by
VDOT in order to permit and construct access. Any proposed street trees within VDOT-maintained ROW will need to
comply with clear zone and landscaping requirements detailed in Appendix A1 and Appendix B1 of the VDOT Road
Design Manual. Any proposed bicycle and pedestrian paths within VDOT right-of-way shall be in accordance with the
VDOT Complete Streets: Bicycle and Pedestrian Guidelines, per Appendix A(1). During the plan review process, VDOT will
require trip generations and turn lane warrant analysis based on the proposed site improvements. Any proposed public
roads intended for maintenance by the Virginia Department of Transportation shall be free and clear of any
encumbrances.
All proposed subdivision streets to be state-maintained must comply with all requirements of the 2011 Secondary Street
Acceptance Requirements (SSAR) Regulation, such as roadway width (with consideration for on-street parking and traffic
volume), pedestrian accommodations, and public benefits.
The internal road shown on the Concept Plan (Exhibit A) does not meet the multiple connections in multiple directions
requirement for 2011 SSAR. The applicant should work with the residency through the SSAR process. An approved
waiver will be required at the time of street acceptance. The proposed development should follow the requirements of
Appendix B(1) of the VDOT Road Design Manual.
1. Per Chapter 19.2, the Suburban Community (SC) requires the use of public water and wastewater.
2. Water is available:
a. A twelve (12) inch water line runs through Copper Grove to the west with a six (6) inch line stubbed at
the cul-de-sac of Midway Road. An easement is in place to the western boundary of the 16200 Beach
Road. The Applicant has been advised that upsizing of the six (6) inch line will be required at site plan if
this route is pursued.
b. An eight (8) inch water line is located along Glen Royal Drive to the east within Harpers Mill Section 2.
The Applicant is pursuing an easement to extend the eight (8) inch waterline approximately 510 feet to
the eastern property line.
3. Wastewater is available: An eight (8) inch line is available approximately 125 feet to the northeast of the
Property with an easement in place for extension to the Property line.
4. The Applicant has submitted Proffered Condition 7:
a. The public water and wastewater systems shall be used.
b. In conjunction with recordation of the initial subdivision plat, prior to any final site plan approval, or within
sixty (60) days from a written request by the Utilities Department, whichever occurs first, a thirty (30) foot
permanent waterline easement along the north side of Beach Road, measured from the ultimate right-of-
way, shall be dedicated, free and unrestricted, to and for the benefit of Chesterfield County.
5. The Utilities Department supports this request.
Transportation - Virginia Department of Transportation
Utilities – Water and Wastewater
Page 138 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 14 of 26
Page 139 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 15 of 26
Community Meeting
3/18/2026 – Discussion Topics:
1. Details on portion of the Property being developed
2. Location and impact of wetlands/RPA
3. Buffering between the site and existing Harpers Mill
4. Location of proposed homes on proposed lots and setback areas adjacent to Harpers Mill
5. Proposed utility connections
6. Impact of runoff on adjacent properties
7. Details on proposed land clearing and possible future clearing by future homeowners
8. Concern about tree clearing near Harpers Mill properties impacting their existing trees
9. Desire to keep as much existing tree cover as possible
10. Plans for amenities and concern over future residents using Harpers Mill amenities
11. Questions about Property being added to Harpers Mill HOA
12. Clearing along Beach Road and any impacts on Beach Road and proposed buffer adjustment
13. Design details of proposed homes and lot sizes
14. Details of any proposed fencing
15. Proposed home sales prices and potential impact on existing adjacent home values
16. Impact on any potential remnants of old railroad bed on site
Community Engagement
Page 140 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 16 of 26
1. Concept Plan. Development of the Property shall generally conform to the layout, titled “The Reserve”, prepared
by Balzer and Associates last revised Apil 24, 2026 (the “Concept Plan”). The Concept Plan (Exhibit A) is conceptual
in nature and may vary based on the final approved subdivision plans, as applicable, depending on the final soil
studies, RPA lines, road design, lot locations, lot line locations, open space locations, building f ootprints, VDOT
requirements, BMP design and location, pedestrian way design and location, and other design or engineering
reasons. Any substantive changes that do not relate to the prior sentence shall be approved by the Planning
Director at the time of plans review. In the event of any conflict between information shown on the Concept Plan
and these Proffers, these Proffers shall control. (P)
2. Density. The total number of residential dwelling units shall not exceed thirty-two (32) units. (P)
3. Access. Direct vehicular access from the Property to Beach Road shall be limited to one (1) public road access to
serve the development and one (1) access to serve county/utility facilities, with the exact location of these
accesses to be approved by the Transportation Department. (T)
4. Road Improvements. In conjunction with initial development, the following road improvements shall be
completed, as determined by the Transportation Department. The Transportation Department shall approve the
exact design, length, or other modifications of the improvements.
a. Widening/improving the north side of Beach Road to a eleven (11) foot wide travel lane, measured from
the centerline of the existing pavement, with an additional five (5) foot wide paved shoulder, three (3)
foot wide unpaved shoulder and overlaying the ful l width of the road with one and a half (1.5) inch of
surface asphalt, with any modifications approved by the Transportation Department, for the subject
property frontage (approximately 850 feet) and for the property approximately 1,100 feet west of the
subject property’s western property line (approximately 1,100 feet).
b. Construction of additional pavement along Beach Road to provide right and left turn lanes at the approved
access.
c. Dedication to Chesterfield County, free and unrestricted, of any additional right of way (or easements)
required for the improvements identified above. (T)
5. Dedication. In conjunction with recordation of the initial subdivision plat, prior to any final site plan approval, or
within sixty (60) days from a written request by the Transportation Department, whichever occurs first, forty-five
(45) feet of right -of-way along t he north side of Beach Road, measured from the centerline of the part of the
roadway immediately adjacent to the Property, shall be dedicated, free and unrestricted, to and for the benefit
of Chesterfield County. (T)
6. Drainage.
a. The 100 -year post development peak discharge rate shall not exceed the 100 -year pre -development
discharge rate. The proposed SWM / BMP may include landscaping and if classified as a wet pond a
fountain or other comparable, low maintenance aeration feature may be used, both subject to review and
approval by the Department of Environmental Engineering during plans review.
b. Impervious areas created from the development of the Property shall not sheet flow through the adjacent
properties to the north or east within the Harper’s Mill Southwest Section 2 subdivision. (EE)
Proffered Conditions (8/3/2026)
Page 141 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 17 of 26
7. Utilities.
a. The public water and wastewater systems shall be used.
b. In conjunction with recordation of the initial subdivision plat, prior to any final site plan approval, or within
sixty (60) days from a written request by the Utilities Department, whichever occurs first, a thirty (30) foot
permanent waterline easement along the north side of Beach Road, measured from the ultimate right-of-
way, shall be dedicated, free and unrestricted, to and for the benefit of Chesterfield County. (U)
Subdivision Design Elements
8. Lot Size. The minimum lot size shall be 10,000 square feet, and all lots shall comply with the applicable lot and
building standards of the Suburban Community (SC) District, Option 2, for Single-Family Lots. (P)
9. Driveways. All private driveways shall be hardscaped (concrete, asphalt, pavers or other material approved by the
Planning Director at the time of plans review). (P)
10. Front Walks. Front walks shall be provided from the driveway or sidewalk to the front entrance of a dwelling. All
front walks shall be a minimum of three (3) feet in width and hardscaped (concrete, asphalt, pavers or other
material approved by the Planning Director at the time of plans review). (P)
11. Front Foundation Planting Beds. Foundation planting is required along the entire front and corner side façade(s)
of all dwelling units. Foundation planting beds shall be a minimum of four (4) feet wide from the unit foundation.
Planting beds shall include medium shrubs spaced a maximum of four (4) feet apart. The plant materials used
should visually soften the unit corners and complement the architecture of the home at their mature sizes. (P)
12. Architecture. Development of the residential units shall follow the general look and feel of the designs shown in
Exhibit B or another architectural appearance approved by the Planning Director at the time of plans review. The
designs in Exhibit B are conceptual in nat ure and may vary in detail, including design elements, styles, colors and
materials, at the time of plans review. (P)
13. Exterior Facades.
a. Acceptable siding materials include brick, stone, masonry, fiber cement siding (such as HardiPlank,
HardieShingle, and HardieTrim), or engineered wood siding (such as LP SmartSiding), premium quality
vinyl siding with a minimum thickness of 0.044 inches or other comparable material as approved by the
Planning Department at time of plans review. Plywood and metal siding are not permitted. Other
materials may be used for trim, architectural decorations, or design elements provided they blend with
the architecture of the dwelling unit. Where a dwelling borders more than one street, all street -facing
facades shall be finished in the same materials.
b. If the dwelling is constructed on a slab, brick, brick veneer, stone, stone veneer, or other masonry material
shall be employed around the base of the dwelling a minimum of eighteen (18) inches above grade so as
to give the appearance of a foundation. If not constructed on slab, all exposed portions of the foundation
of each dwelling shall be faced with brick, brick veneer, stone, stone veneer, or other masonry material.
c. Stepping the siding down below the first floor shall only be permitted in circumstances of unique
topographical conditions. For dwelling units stepping the siding down below the first floor shall be
permitted on the side and rear elevations that do not fro nt on a street, with a maximum of two (2) steps
permitted on any elevation. A minimum of eighteen (18) inches of exposed brick or stone shall be
required, unless a lesser amount is approved by the Planning Department at the time of plan review due
to unique design circumstances.
Page 142 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 18 of 26
d. Roof materials on pitched roofs shall be thirty (30) year minimum architectural / dimensional asphalt
composition shingle or standing seam metal.
e. At least 50% (5 in 10) dwelling units constructed shall have brick, stone or masonry fronts that cover a
minimum of 20% of the front façade (which façade shall exclude gables, windows, trim, and doors). (P)
14. Elevation Repetition. The same dwelling unit elevations shall not be located adjacent or directly across from each
other along the same road. This requirement does not apply to units on different streets backing up to each other.
Variation in the front elevation shall not be achieved by simply mirroring the façade but may be accomplished by
providing at least three (3) of the following architectural changes.
a. Adding or removing a front porch or covered entry or increasing or decreasing the length of the porch or
entry.
b. Adding masonry on the front façade elevation of the first floor.
c. Varying the location and/or style of the roof type, roof line, front facing gable(s), and /or dormers.
d. Providing varied siding applications using horizontal siding, shake siding, an/or board and batten siding.
e. Adding projections such as bay windows, second floor balconies, and accent roofs.
f. Alternating the location of a garage, if provided.
g. Providing a different architectural style.
h. Any other element of architectural variation as provided by the Director of Planning. (P)
15. Porches & Stoops . Front stoops and porches shall be constructed with continuous foundation walls or masonry
piers to match the foundation of the home. Front porches shall be a minimum of four (4) deep. (P)
16. Garages.
a. Any garage door visible from a public street shall use an upgraded garage door. An updated garage door
is any door with a minimum of three (3) enhanced features. Enhanced features shall include windows,
raised panels, decorative panels, arches, ornamental hardware or other architectural features on the
exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs, arches, columns, keystones,
eyebrows, etc.). Flat panel doors shall be prohibited.
b. If a home has a front-facing garage door in front of, or on the same building elevation plane, as the primary
front elevation plane (i.e. the portion of the building front elevation with the largest width), then the home
shall include a covered porch or a covered stoop and the building elevation plane with the garage door
shall not extend more than six (6) feet from the nearest portion of the front porch or front stoop plane.
Thirty (30) percent of the homes may have a garage projection that extends up to ten (10) feet from the
front porch or front stoop plane and shall incorporate a shed roof overhang or other similar overhang (in
addition to the enhanced features requirement listed above). This proffer shall not apply to front facing
garage doors located behind the primary front elevation plane.
c. A minimum of two (2) decorative exterior wall mounted lights shall be provided for homes with one garage
door (one on each side). A minimum of three (3) decorative exterior wall mounted lights shall be provided
with homes with two garage doors (one on each side and one in the middle). (P)
17. Heating Ventilation and Air Conditioning (HVAC) Units and Whole House Generators. Units shall initially be
screened from view of roads by landscaping or low maintenance material, as approved by the Planning
Department. (P)
18. Fireplaces, Chimneys and Flues. If provided and in addition to the requirements of the Zoning Ordinance, the
following shall be required.
Page 143 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 19 of 26
a. Masonry fireplace chimney chases shall be constructed of brick or stone. The width and depth of chimneys
shall be appropriately sized in portion to the size and height of the unit.
b. All the exterior materials and finishes used to enclose the fireplace box must match the adjacent façade.
(P)
19. Buffers.
a. A twenty -five (25) foot buffer shall be provided along the Beach Road frontage of the property, as
generally shown on the Concept Plan. This buffer shall meet the Zoning Ordinance standards for 2.1 x
Landscape B and shall be exclusive of the permanent waterline eas ement. Existing vegetation within this
buffer shall be preserved to the maximum extent practicable.
b. A thirty-five (35) foot buffer shall be provided along the east and north property boundaries, as generally
shown on the Concept Plan. This buffer must comply with the Zoning Ordinance requirements for
treatments between differing zoning districts in cases where the required buffer width is less than fifty
(50) feet. (P)
20. Amenity Space. A minimum 48-inch-wide pedestrian path constructed with a base of #57 stone, 21A stone, and
rolled, as generally shown on the Concept Plan, shall be provided as passive recreation within the natural/forested
areas located in the western portion of the dev elopment. This path will provide connection(s) to the internal
sidewalk network. The final alignment and configuration of the pedestrian path system shall be determined during
plans review in conjunction with engineering of the stormwater management facility. Seating areas or informal
gathering spaces may be incorporated along the path, subject to review and approval during plans review. (P)
21. Entry Monument. An entry monument with signage and landscaping shall be provided at the entrance of the
development from Beach Road. The exact design, location and size of the monument with landscaping shall be
reviewed by the Planning Department during plans review. (P)
22. Lighting.
a. For cluster mailbox units (CBUs) located outside, full cut -off, photocell-activated, minimum 70 CRI-rated
LED luminaires shall illuminate areas within 20 feet of the CBUs with a minimum maintained illumination
level of 0.5 foot -candles, as measured at grade, but this requirement may be reduced and modified to
meet VDOT requirements.
b. One (1) lamp post shall be provided in the front yard of each dwelling unit. The design of such lamp posts
shall be consistent throughout the Property. (P)
Page 144 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 20 of 26
Request for Adjustments to Ordinance Requirements
with Justification and Mitigating Enhancements
Pursuant to Chapter 19.2 -51-1 Adjustments to Ordinance Requirements , the applicant may request adjustments to
development standards of the Zoning Ordinance as part of a proffer statement provided there is appropriate and sufficient
justification along with mitigating enhancements demonstrated in the request. The following adjustments to development
standards are being requested with this zoning application:
Adjustment 1: Chapter 19.2-35. B.3 & Table 19.2-35.3 Buffers Adjacent to Roads for Subdivisions.
The applicant requests a reduction of the required one hundred (100)-foot buffer along Beach Road, an arterial
roadway, to a minimum buffer of twenty-five (25) feet, exclusive of easements.
Table 19.2-35.3 requires a fifty (50) foot buffer adjacent to arterial roads; however, for properties located within the
Upper Swift Creek Special Buffer Area, the required buffer width increases to one hundred (100) feet. While the zoning
map indicates that the subject property is within the Upper Swift Creek Special Buffer Area, Environmental Engineering
has confirmed that only a very small portion of the northeast corner of the site lies within the Upper Swift Creek
watershed, which is shown as preserved open space on the concept plan, and the majority of the property is not located
within the watershed. In addition, the Utilities Department has requested that the applicant proffer a thirty (30) foot
wide permanent waterline easement along Beach Road to accommodate a proposed thirty-six (36) inch waterline
associated with Utility Project 24-0186. Although the proposed development will not connect to this waterline, the
improvement will serve other County projects and properties. As this is a publicly funded project, the applicant agrees to
dedicate a seventy-five (75) foot wide utility easement along Beach Road (inclusive of the forty-five (45) foot right-of-
way shown on the Utility Plan) and to maintain a minimum twenty-five (25) foot buffer between the easement and the
rear of the proposed lots as described in Proffered Condition 19. This approach is consistent with Section 19.2-35. E.2.b
of the Zoning Ordinance regarding encroachments for publicly funded projects.
The requested buffer reduction is mitigated through the provision of amenity space for the development as well as a
buffer along the east and north property lines, as described in Proffered Conditions 19 & 20. While amenity space is not
required for subdivisions containing fewer than fifty (50) lots, the applicant is voluntarily providing this feature to offset
the reduced buffer width. The applicant is also proffering to dedicate the thirty (30) foot wide permanent waterline
easement along Beach Road to Chesterfield County free and unrestricted, resulting in a public infrastructure
improvement that will not serve this development but will function as a county asset. From a landscaping perspective,
the applicant will coordinate with Planning and Utilities during the plan review process, and following final identification
of the easement location, to install medium-sized shrubs within the easement where permitted. This landscaping, in
combination with the twenty-five (25) foot buffer between the easement and the rear of lots, will provide a landscaped
area totaling approximately fifty-five (55) feet between the right-of-way and the rear of the proposed lots, enhancing
the visual character along Beach Road.
Justification for Adjustment to Ordinance Requirements
Page 145 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 21 of 26
Concept Plan – Exhibit A
Page 146 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 22 of 26
Conceptual Elevations – Exhibit B
Page 147 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 23 of 26
Applicant
• Applicant’s Agent:
Anne Miller (804-707-7149)
• Applicant’s Contact:
Zack Lapinski (804-221-7247)
District Planning Commissioner
• Christopher Chapman
chapmanch@chesterfield.gov
Staff
• Planning Department Case Manager: Harold Ellis (804-768-7592) ellish@chesterfield.gov
• Budget & Management: David Oakley (804-706-2586) oakleyd@chesterfield.gov
• Community Enhancement: Brian Chamberlain (804-748-1541) chamberlainb@chesterfield.gov
• Environmental Engineering: Douglas Miles (804-768-7797) milesd@chesterfield.gov
• Fire & Emergency Medical Services: Christopher Harding (804-971-0399)
hardingc@chesterfield.gov
• Libraries: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov
• Parks & Recreation: Laura Baker (804-717-6354) bakerla@chesterfield.gov
• Police: Jim Eicher (804-318-8693) eicherj@chesterfield.gov
• Schools: David Oakley (804-706-2586) oakleyd@chesterfield.gov
• Transportation - County Department of Transportation: Steve Adams (804-751-4461)
adamsst@chesterfield.gov
• Transportation - Virginia Department of Transportation: Dustin Dunnagan (804-674-2384)
dustin.dunnagan@vdot.virginia.gov
• Utilities: Alan Harrison (804-796-7126) harrisonl@chesterfield.gov
Case Contacts
Page 148 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 24 of 26
Mission & Service Profile
The mission of Chesterfield Fire and Emergency Medical Services (CFEMS) is to protect life, property and the
environment. This requires a comprehensive portfolio of services aimed at preventing fires, mitigating the impact of
fires and disasters on the community, and providing a timely and effective response when fires, medical and other
emergencies occur. Community risks, population growth and demographic changes, service demands, and response
times are reviewed annually and the need for additional Fire & EMS operating and capital resources in support of the
department’s mission is evaluated during the county’s annual budget and 5-year Capital Improvement Plan (CIP)
processes.
Community Fire Protection Capabilities Assessment
Chesterfield Fire and EMS participates in the Insurance Services Office (ISO) Public Protection Classification (PPC)
program, which rates a community’s fire protection capabilities in accordance with the Fire Suppression Rating Schedule
(FSRS). Using the FSRS, the ISO performs a comprehensive evaluation of a community’s fire department, water supply,
emergency communications and community risk reduction efforts. The resulting score establishes a PPC rating from 1 to
10, with Class 1 being the best possible rating. Many insurance carriers reference a community’s PPC rating in
establishing insurance premiums. Generally, communities with a Class 1 rating enjoy lower insurance premiums than
those communities with a Class 10 rating. Chesterfield County has a current community classification of 2/2Y, however
some portions are classified as 10 or 10W based on the parameters indicated below;
Class 2 - within 5 miles of a fire station and within 1,000 feet of a fire hydrant.
Class 2Y – within 5 miles of a fire station but not within 1,000 feet of a fire hydrant.
Class 10W – within 5-7 miles of a fire station and within 1,000 feet of a fire hydrant.
Class 10 – outside of 5 miles of a fire station and not within 1,000 feet of a fire hydrant.
Appendix
Fire & Emergency Medical Services
Page 149 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 25 of 26
Response Time Goals (Urban/Rural Zones)
Urban Zone
Fire and EMS response goal is 7 minutes from receipt of call in the Emergency Communications Center (ECC) to arrival of
first responding unit. Fire and EMS facilities should be strategically located to provide 4 minutes or less travel time for
the first arriving engine company at a suppression incident, and 8 minutes or less travel time for deployment of an
Effective Firefighting Force (first alarm assignment) at a suppression incident.
Rural Zone
Fire and EMS response goal is 12 minutes from receipt of call in the Emergency Communications Center (ECC) to arrival
of first responding unit. Fire and EMS facilities should be strategically located to provide 9 minutes or less travel time for
the first arriving engine company at a suppression incident, and 13 minutes or less travel time for deployment of an
Effective Firefighting Force (first alarm assignment) at a suppression incident.
Page 150 of 218
The Reserve Rezoning & Adjustments 25SN1332 Page 26 of 26
Mission
High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The
comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater
access, flexible designs and locations that better meet the needs of the communities in which they are located.
Capital Improvements
The School Board FY2026 approved five-year Capital Improvement Plan (CIP) continues to support the 2022 voter
approved bond referendum. The approved CIP will replace or renovate seven schools and construct five new schools to
add an additional capacity of approximately 8,500 seats countywide. The existing facilities that are part of the
replacement and renovation program are A.M. Davis Elementary (completed August 2025), Bensley Elementary (to open
August 2026), Grange Hall Elementary, Falling Creek Middle School (completed August 2024), Matoaca Middle,
Midlothian Middle, and Thomas Dale High. The five new schools include a Deep Creek Middle School (completed August
2025) and Deep Creek Elementary School (to open August 2026) near Westerleigh Parkway. A Western Area High School
will also open in 2027 near Duval Road. A new Dale District and an Old Hundred Area Elementary School are also in the
CIP. Information on the CIP and School Board approved construction projects can be found in the financial section of the
CCPS Adopted Budget for FY2026 or the County CIP Dashboard.
Schools
Page 151 of 218
25SN1332 – Matoaca
Rezone from Agricultural (A) to Suburban Community (SC) with
adjustments to ordinance requirements for development
standards.
The Reserve Rezoning and Adjustments
25SN1332, in the Matoaca District, is a request to rezone from the Agricultural (A)
District to the Suburban Community (SC) District with adjustments to ordinance
requirements for development standards.
1
Page 152 of 218
25SN1332 – Overview
1. Rezoning to SC with adjustments
to ordinance requirements
• 32 residential lots
• Min 10,000 sq ft lots
• 1.64 dwelling units per
acre
• Adjustment to buffer
along Beach Road
2. 35’ buffer adjacent to Harpers
Mill subdivision
3. Staff recommends approval
A residential development is proposed consisting of up to thirty-two (32) single-
family dwellings. The minimum lot area will be 10,000 square feet and the density
of the development is 1.64 dwelling units per acre. The applicant proposes a buffer
adjacent to existing Harpers Mill, as well as a pedestrian trail connecting to a
required shared use path along Beach Road. The applicant requests an adjustment
to ordinance requirements to reduce the width of the required buffer along Beach
Road to assist in accommodating a County utility line project. Staff recommends
approval.
2
Page 153 of 218
25SN1332 – Zoning Map
The subject property, outlined in red above, is located along the north side of Beach
Road, west of Otterdale Road, adjacent to the Harpers Mill subdivision, and is
currently zoned Agricultural (A), as is property to the south. Properties to the
north, east, and west are zoned Suburban Community (SC).
3
Page 154 of 218
25SN1332 – Aerial & Land Use Plan Map
The subject property is outlined above. As illustrated on the aerial plan, the site is
currently undeveloped. The land use designation for the property is Residential
Neighborhood 2.
4
Page 155 of 218
25SN1332 – Conceptual Layout Plan
A residential development is proposed consisting of up to thirty-two (32) single-
family dwellings. The minimum lot area will be 10,000 square feet and the density
of the development is 1.64 dwelling units per acre. The applicant proposes a buffer
adjacent to existing Harpers Mill, as well as a pedestrian trail connecting to a
required shared use path along Beach Road. An adjustment to ordinance
requirements is requested to reduce the width of the required buffer along Beach
Road to assist in accommodating a County utility line project.
5
Page 156 of 218
25SN1332 – Conceptual Elevations
These are the proposed conceptual elevations. In addition to proffered variation in
elevations, acceptable siding materials include brick, stone, masonry, fiber cement
siding (such as HardiPlank, HardieShingle, and HardieTrim), engineered wood siding
(such as LP SmartSiding), or high-grade vinyl.
6
Page 157 of 218
25SN1332 – Recommendation
1. Staff – Approval
• Proposal falls within the recommended density of the
Comprehensive Plan
• Quality design standards for lot development and architecture
provided
The proposed development provides quality design and architecture resulting in an
attractive and harmonious community and will result in a reduction in density and
unit count currently permitted on the Property. The proposal’s overall residential
density of 1.64 dwelling unit per acre falls below the Plan’s recommended
residential density of 2.0 dwelling unit per acre or less. And lastly, quality design
standards for lot development and architecture have been proffered by the
applicant to create a unique and viable development. Staff recommends approval.
7
Page 158 of 218
25SN1332 – Zoning Map
8
Page 159 of 218
Gallimore Accessory Buildings Rezoning & Adjustments 26SN2055 Page 1 of 2
26SN2055 – Gallimore Accessory
Buildings Rezoning &
Adjustments
Magisterial District – Midlothian
Applicant – Maurice Gallimore (804-921-2839)
CPC Public Hearing – August 18, 2026
Time Remaining
100 Days
Case Manager
Haley Gibson
(804-748-1071)
Request
Rezoning &
Adjustments to Ordinance Requirements
Construction of a new accessory building (detached
garage) is planned. Relief to setbacks for the proposed
accessory building and two (2) existing accessory buildings
(frame sheds) is requested.
Staff Recommendation
Approval
The Property
12101 Old Buckingham Road
Site Size
0.45 Acre
Comprehensive Plan –
Land Use Designation
Residential Neighborhood 4
Plan Area
County Wide Plan
Figure 1: Aerial of Request Area – Click Image for Link to GIS
Figure 2: Area Map of Request & Land Use Plan Map
Rezoning from Suburban Community (SC) to Suburban Community (SC) with adjustments to development standards
relative to setbacks for a proposed detached garage and two (2) existing accessory buildings (frame sheds).
The applicant proposes to construct a new detached garage on the Property to store personal vehicles. The proposed
detached garage would be located in the corner side yard, and the applicants are proposing a lesser setback from the
corner side property line than what the Zoning Ordinance requires. Additionally, as staff was evaluating the request, it
was discovered that the two (2) existing frame sheds in the rear yard do not meet required setbacks as outlined in the
Zoning Ordinance. Therefore, this zoning request includes an adjustment for the proposed and existing accessory
buildings setbacks.
Staff Note: This request is subject to the procedural and development regulations provided
in Chapter 19.2 of the Zoning Ordinance.
Summary of Proposal
Page 160 of 218
Gallimore Accessory Buildings Rezoning & Adjustments 26SN2055 Page 2 of 3
STAFF - APPROVAL
The applicants have owned the Property since January of 2001. The proposed detached garage will provide an indoor
space for the applicants to store their person vehicles. Additionally, the detached garage will be surrounded by
landscaping and be constructed of horizonal metal siding that matches the same color and design of the existing
dwelling and accessory buildings on the Property. The existing accessory buildings have been located on the Property in
the rear yard since 2001. Approval of the setback adjustment will bring two (2) existing accessory buildings into
compliance with today’s standards as set forth in the Zoning Ordinance.
NOTES FOR THE PLANNING COMMISSION AND BOARD OF SUPERVISORS
1. The only condition that may be imposed is a buffer condition. The property owner may proffer conditions.
2. Proffered conditions, a proposed layout plan, and conceptual elevations have been submitted by the applicants.
Recommendation
Page 161 of 218
Gallimore Accessory Buildings Rezoning & Adjustments 26SN2055 Page 3 of 4
Summary of Proposal .............................................................................................................................................................. 1
Recommendation .................................................................................................................................................................... 2
Table of Contents ................................................................................................................................................................... 3
Planning................................................................................................................................................................................... 4
Current Zoning Map ..........................................................
Text truncated. Open the original for the full document.
Source: Chesterfield County website. First collected Oct 5, 2026.