RecordWell Data

Planning Commission Meeting Packet (PDF)

City of Suffolk · Suffolk City County · meeting of Oct 20, 2026 · Agenda packets

Open the original document More from City of Suffolk

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

SUFFOLK PLANNING COMMISSION AGENDA FOR OCTOBER 20, 2026 PREPARED BY THE CITY OF SUFFOLK DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT KEVIN WYNE, AICP, DIRECTOR OF PLANNING & COMMUNITY DEVELOPMENT THE REGULAR MEETING WILL BE HELD AT 2:00 P.M. IN THE SUFFOLK CITY COUNCIL CHAMBERS OF THE CITY HALL BUILDING IF YOU CANNOT ATTEND OR NEED SPECIAL ACCOMODATIONS AT THE MEETING, PLEASE CALL THE CITY OF SUFFOLK DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT AT (757) 514-4060 PRIOR TO 12:00 NOON ON FRIDAY, OCTOBER 16, 2026. ANITA HICKS CHAIRMAN Page 1 AGENDA SUFFOLK PLANNING COMMISSION October 20, 2026 2:00 P.M. 1. Call to Order A. Invocation B. Pledge of Allegiance C. Roll Call 2. Approval of minutes from previous meeting 3. Family Transfer Subdivision Plat: A. FAMILY SUBDIVISION PLAT, FTR2026 -0004, submitted by Annette Tonkin Brooks, applicant, on behalf of The Annette Tonkin Brooks Revocable Trust, property owner, requesting a family subdivision pursuant to Section 31- 514 of the Unified Development Ordinance, to approve a Family Subdivision Plat to create one (1) new parcel, on property located at 3400 Knotts Neck Road, Zoning Map 5, Parcel 33A . The affected property is further identified as being located in the Sleepy Hole Voting Borough, zoned RR, Rural Residential zoning district. The City’s 2045 Comprehensive Plan identifies this property as being located within the Traditional Neighborhood Land Use Type. 4. Public Hearings: A. ORDINANCE TEXT AMENDMENT, OTA2026-010, initiated by the City of Suffolk, for amendments to Sections 31-604(e), 31-604(h), 31-605(b), 31-606 (a), 31-606(c), 31-612(p), 31-612(k), 31 -701, 31- 702(d), 31- 702(e), 31- 708(a), 31 -801(e), and Appendix B of the Unified Development Ordinance of the City of Suffolk, Virginia B. ORDINANCE TEXT AMENDMENT, OTA2026-011, initiated by the City of Suffolk, for amendments to Sections 31-506(b) and 31-605(h) of the Unified Development Ordinance of the City of Suffolk, Virginia 5. Old Business 6. New Business A. Staff Report – Significant Land Use Item • REZONING REQUEST, RZN2026 -00002, Pruden Lake Prince: to rezone and amend the official zoning map of the City of Suffolk in order to change the zoning Page 2 from RE, Rural Estate zoning district to RM, Residential Medium Density (Conditional) Zoning District and B -2, General Commercial (Conditional) Zoning District, for property located at 3840 Pruden Boulevard and Lake Prince Drive, Zoning Map 24, Parcels 5 and 6. B. Staff Report – Amendments to the Table of Uses and Definitions in Appendix A of the Unified Development Ordinance C. Staff Report – Cannabis Regulations D. Status Report - City Council Meeting, September 16, 2026 E. Status Report - Preliminary Plats Approved 7. Commissioner’s Comments 8. Adjournment 1 MINUTES SUFFOLK PLANNING COMMISSION September 15, 2026 2:00 P.M. The meeting of the Suffolk Planning Commission was held on Tuesday, September 15, 2026, at 2:00 p.m., in the Council Chambers of the Municipal Building, 442 W. Washington Street, Suffolk, Virginia, with the following persons present: MEMBERS: Anita Hicks, Chairman Oliver Creekmore, Vice-Chairman Mary Ellen Baur Gerald Goodman Thomas Powell Selena Thornton-Manuel Johnnie Edwards David Bosselman STAFF: William Hutchings, Jr., City Attorney Margaret Pittenger, Asst. Dir. of Planning William Mellon, Zoning Administrator Caitlin Aubut, Land Use Planning Manager Jonathan McBride, Comp. Planning Manager Goncalo Borges, Senior Planner Cassidy McKelvie, Senior Planner Isabella Reynolds, Planner I Yasaman Maleki, Planner I Lisa Marshall, Asst. Zoning Administrator Karl Schulz, Planner II Catina Myrick, Administrative Analyst The meeting was called to order by Chairman Hicks. Commissioner Edwards offered the Invocation and led the Pledge of Allegiance. The roll was called by Mr. Wyne and the Chairman was informed that a quorum was present. APPROVAL OF MINUTES: The minutes of the previous meeting were approved as written. RECOGNITION OF SERVICE: ` 2 On behalf of the Commission, Chairman Hicks presented a Resolution of Appreciation to Mr. Staylor for his years of service on the P lanning Commission. PUBLIC HEARINGS: REZONING REQUEST, RZN2025 -00002, Towne Creek: submitted by Bob Arnette, 1427 Holland Road, LLC, applicant, on behalf of Stanley Martin Homes, LLC, property owner, in accordance with Sections 31-304 and 31-305 of the Unified Development Ordinance, to rezone and amend the official zoning map of the City of Suffolk in order to amend the previously approved proffered conditions, for property located at 1407, 1419 and 1427 Holland road, Zoning Map 33, Parcels 66, 66C and 66D. The purpose of this request is to amend previously approved proffers pertaining to the number of residential dwelling units. The affected area is further identified as being located in the Holy Neck Voting Borough, zoned RU, Residential Urban (Conditional) Zoning District. The 2045 Comprehensive Plan designates this area as part of the Central Growth Area, Traditional Neighborhood Land Use Type. The first item of business was introduced by the Chairman followed by a staff report by Goncalo Borges, Senior Planner. Mr. Borges stated that this request is to amend previously approved proffered conditions on properties located at 1407, 1419, and 1427 Holland Rd for the purpose of including 17 additional units in the Towne Creek development, thus increasing the amount of total units from 140 to 157. In condition #1, the applicant amended the school capacity advancement cash contributions to mitigate the impact of 4 new students generated by the addition of 17 new units. The applicant amended Condition #1 by proposing a total cash contribution of $143,602.2 total, or $8,447.1 per dwelling unit, or $35,900.55 per student. Since the original cash contribution from RZN2018- 007 (Conditional) was a total of $688.750, with the 3 additional 17 units and the 4 students generated at the Elementary School level, the total value of this cash contribution of $832.352 – to make up for the difference. Condition #2, the applicant propos ed to increase the maximum number of allowed units from 140 to 157 total attached and detached single -family dwelling units. Condition #7, the applicant is changing the warranty for roof shingles from 35 years to 30 years. With the additional 17 units, now 157 detached and attached units, which is increasing density to 7.2 dwelling units per acre, RU is 10.9 DU per acre within the Traditional Neighborhood Land Use Type’s density range of 4-10 dwelling units per acre set by the 2045 Comprehensive Plan. The proposed use and density remain compatible with the existing surrounding uses, zoning designations, and land use types. The Department of Public Utilities ha d no objections to the amendment application at this time. The Department of Public Works’ Eng ineering Division reviewed the request and stated that the developer will have to finalize an encroachment agreement with Dominion Energy for their easement that crosses the property before plan approval. The applicant submitted a revised Traffic Impact Study. Per the Institute of Transportation Engineers’ (ITE) Trip Generation Manual, an additional 17 single-family detached units will generate 4 “in” and 11 “out” trips at the morning peak hour, and 12 “in” and 7 “out” trips at the afternoon peak hour. The full development will generate 198 average daily trips and the 17 additional units will 4 contribute 15 trips at the morning peak hour and 19 at the afternoon peak hour. Regarding the Intersection Capacity Analysis, per the traffic impact study , both signalized intersections are expected to operate satisfactorily in the built condition. The traffic impact study stated that turn lanes are required per City code. However, there is currently a two-way left turn lane along the Holland Road frontage, so only the addition of right turn lanes is required. This improvement has already been proffered as part of the original approved development. The proposed development, as amended, meets the required conditions for adequate public facilities, and does not negatively impact the already approved conditions from the original rezoning nor the orderly planning and development in the vicinity of the subject properties. Therefore, staff recommended approval of this application with the amended proffered conditions in the staff report. The public hearing was opened and speaking in favor of this application was Sam Baraki, 300 Cedar Lake Drive, Chesapeake, VA. Speaking in opposition was Blake Baker, R. W. Baker Funeral Home, 1401 Holland Road, Suffolk, VA. Also, speaking in opposition was David Lego, 112 Royal Oak Ct., Suffolk, VA. There being no more speakers, the public hearing was closed. 5 After discussion by the Commission, Commissioner Goodman made a motion to approve this application with the amended proffers , seconded b y Commissioner Edwards and failed by a recorded vote of 4 to 4. CONDITIONAL USE PERMIT REQUEST, CUP2025-00018, Harbour Pointe In-Law Suite: submitted by Timothy Schaffner and Sara Serji, applicants and property owners, in accordance with Sections 31-306 and 31-406 of the Unified Development Ordinance, to grant a Conditional Use Permit to establish a detached accessory dwelling unit on property located at 6528 Harbour Pointe Drive, Zoning Map 6E, Parcel RF*DD*13. The affected area is further identified as being located in the Sleepy Hole Voting Borough, zoned PD, Planned Development Zoning District. The 2045 Comprehensive Plan designates this area as part of the Northern Growth Area, Traditional Neighborhood Land Use Type. The next item of business was introduced by the Chairman followed by a staff report by Isabella Reynolds, Planner I. Ms. Reynolds stated that this conditional use permit request is to establish an accessory dwelling unit. The proposed accessory dwelling unit will be located in the rear of the subject property which abuts a tidal creek off the Nansemond River. The proposed accessory dwelling unit will be approximately 920 square feet in size and will primarily be utilized by the applicants' parents to reside in. The size of the primary dwelling is approximately 2,988 square feet ; therefore, the proposed accessory dwelling unit satisfies this criteria as the proposed square footage is 920. In conclusion, this conditional use permit request does sufficiently satisfy the criteria set forth i n the UDO. The proposed accessory dwelling unit align with the character of the principal structure and the neighborhood. Also, the proposed 6 accessory dwelling unit is not anticipated to have adverse impacts to the surrounding community. Therefore, staff recommended approval of this application with the conditions noted in the staff report. The public hearing was opened and speaking in favor of this application was Brian Layne, 7021 Harbourview Blvd., Suffolk, VA. There being no speakers in opposition, the public hearing was closed. After discussion by the Commission, Commissioner Baur made a motion to approve this application with the conditions , seconded by Commissioner Creekmore and passed by a recorded vote of 7 to 0 to 1. ORDINANCE TEXT AMENDMENT, OTA2026-007, initiated by the City of Suffolk, for amendments to Sections 31-301(a), 31-301(h), 31-301(i), 31-306(g), 31- 307(a), 31-309(d), 31-413(g), 31-509(c), and 31-603(e), of the Unified Development Ordinance of the City of Suffolk, Virginia. The next item of business was introduced by the Chairman followed by a staff report by Caitlin Aubut, Land Use Planning Manager. Ms. Aubut stated that this application contains a series of proposed amendments to the UDO. 1) Section 31-301(a)(3)(i) – Application Resubmittal – Filing Term: A new subsection is proposed tha t a resubmittal of an administratively approved plan (site plan, subdivision plat, engineering plan) must be received within 180 days from the most recent comment letter to resubmit or otherwise be subject to closure upon notice to the applicant and must be filed as a new application upon the next submittal. 2) Proposed Section 31 - 7 301(a)(3)(ii) provides that a resubmittal of conditional use permit, rezoning and comprehensive plan amendments must be resubmitted within one year of the date of the most recent comment letter, or the application will be closed upon notice to the applicant and any submission afterwards will be processed as a new submittal. 3) Section 31-301(h)(3) – C onduct of Public Hearing s: Remove outdated City code reference and correct it to general reference that public hearings shall be in accordance with state law and City code. 4) Section 31-301(i)(2) – Correct process for appealing City Council decisions: Remove language stated that CUP’s decision appeals must be filed with the Director. Correct to state that appeal contesting decision must be filed with the Suffolk Circuit Court within 30 days of City Council’s decision in accordance with state code. 5) Section 31-306(g)(1) - Minor CUP Modifications : Modify language to read “Non-material and insignificant shifts in on-site location that are determined by the Director will not result in substantial alterations of the site design and layout beyond what was originally approved, or a five-percent (5%) or less increase in either lot coverage or floor area over what was originally approved”. 6) Section 31-309(d) – Remove BZA Variance Expiration – modify language to read: A variance or any determination by the Board of Zoning Appeals on appeal from an officer, department, board or bureau pursuant to this Section shall not authorize the use, occupancy, or development of land. Following an appeal, the applicant may apply 8 for a zoning permit, which zoning permit shall be issued if in conformance with the terms of the ruling of the Board of Zoning Appeals and all other applicable provisions of this Ordinance. Rights and privileges established by the granting of a variance shall be exercised within one year following the date of approval unless a different time limit is specified by the Board of Zoning Appeals at the time the variance is granted. Failure to exercise a variance within the time limits specified shall cause the variance to become null and void. 7) Section 31-307 - Telecom Co-location: Modified slightly to allow the colocation of antennae on telecommunications towers without a site plan, unless land disturbance or improvements on the ground are proposed. 8) Section 31- 413(g)(4) – HC District: Signs or artwork installed by a governm ental agency are proposed to be exempted from review by the Historic Landmarks Commission. 9) Section 31-509(c)(2) – Final Plats: Proposed to be modified to require that the surveyor’s certification statement on a plat must be dated within 180 days prior to submitting the plat for review by City staff. 10) Section 31-603(e)(3) - Landscaping Standards: Staff recommended removing an exemption that allows areas devoid of woody plant material exceeding five feet in height to be excluded from a tree canopy calculation. The existing exemptions for school sites, playing fields, and wetlands are preserved. An additional minor change in Section 31-603(e)(2) updates the reference to the American Standard for Nursery Stock. The above housekeeping amendments 9 are proposed to keep Suffolk’s UDO current by updating minor regulations, streamlining standards, and addressing common issues for more efficient administration and consistent interpretation. Therefore, staff recommended approval of this ordinance text amendment as noted in Exhibit B of the staff report. After discussion by the Commission, Commissioner Edwards made a motion to approve this ordinance text amendment, seconded by Commissioner Creekmore and passed by a recorded vote of 8 to 0. ORDINANCE TEXT AMENDMENT OTA2026-008, initiated by the City of Suffolk, for amendments to Unified Development Ordinance of the Code of the City of Suffolk to amend Section 31-406(c) and Appendix A of the Unified Development Ordinance. The purpose of the text amendment is to update and refine the Code of the City of Suffolk, Chapter 31, Unified Development Ordinance. The next item of business was introduced by the Chairman followed by a staff report by Margaret Pittenger, Assistant Director of Planning. Ms. Pittenger stated that City Council approved a motion directing the Planning Commission to draft an amendment to the UDO to prohibit data centers as a use in all zoning districts. Staff prepared a proposed amendment to Section 31-406, Use Regulations, specifically Subsection 31- 401(c) Permitted Uses, Table 406-1: Principal Uses Permitted in Zoning Districts, that lists Data Ce nter in the table as a Prohibited Use in all zoning districts. Staff also proposed the creation of a definition of Data Center within Appendix A. Additionally, staff proposed amendments to the existing definitions for Trucking Terminal, 10 Warehousing and Distribution, General, Warehouse and Freight Storage, and Warehousing Wholesale, and Distribution, Limited to clarify that these uses do not include uses that are defined as a Data Center. In that regard, staff recommended approval of this ordinance text amendment as noted in Exbibit B in the staff report. After discussion by the Commission, Commissioner Bosselman made a motion to approve this ordinance text amendment , seconded by Commissioner Edwards and passed by a recorded vote of 8 to 0. NEW BUSINESS: Staff Report: Amendments to the Table of Uses and Definitions in Appendix A of the UDO Staff gave a brief discussion on the proposed amendments to the Table of Uses and Definitions in Appendix A of the UDO. APPOINTMENT OF FY 2028-2037 CIP SUBCOMMITTEE: Commissioners Edwards and Powell were appointed to serve on the Capital Improvements Plan Subcommittee. STATUS UPDATE: Mr. Wyne reported on the results of the August 19 th City Council meeting. COMMISSIONER’S COMMENTS: Commissioner Thornton-Manuel requested that staff prepare an annual report of the Planning Commission at the end of the year. 11 ADJOURNMENT: There being no further business, the meeting was adjourned. MT: Goodman 2ND: Edwards TO: Approve w/amended proffers MT: Baur 2 ND: Creekmore TO: Approve w/conditions MT: Edwards 2 ND: Creekmore TO: Approve MT: Bosselman 2 ND: Edwards TO: Approve VOTE: 4-4 VOTE: 7-0-1 VOTE: 8-0 VOTE: 8-0 RZN2025-02 CUP2025-018 OTA2026-07 OTA2026-08 PRESENT ABSENT YES NO YES NO YES NO YES NO Baur, Mary Ellen X X X X X Bosselman, David X X X X X Creekmore, Oliver X X X X X Edwards, Johnnie X X X X X Goodman, Gerald X X X X X Hicks, Anita X X X X X Powell, Thomas X X X X X Thornton-Manuel, Selena X X Abstained X X PLANNING COMMISSION MEETING September 15, 2026 STAFF REPORT DESCRIPTION FAMILY SUBDIVISION PLAT FTR2026-00004 : Family Subdivision Plat, FTR2026-00004, requesting a Family Subdivision to create one (1) new parcel pursuant to Section 31-514 of the Unified Development Ordinance APPLICANT: Submitted by Annette Tonkin Brooks, applicant, on behalf of The Annette Tonkin Brooks Revocable Trust, property owner. A copy of this staff report was sent to the applicant on October 16, 2026. LOCATION: The subject property is located at 3400 Knotts Neck Road and is further identified as Zoning Map 5, Parcel 33A. PRESENT ZONING: RR, Rural Residential zoning district. EXISTING LAND USE: The property is 17.50 acres in size and features a single-family dwelling. PROPOSED LAND USE: This family subdivision is a proposal to create one (1) new lot for Timothy Ryan Moring, who is an immediate family member of Annette Tonkin Brooks, the beneficiary and trustee of The Annette Tonkin Brooks Revocable Trust. Annette Tonkin Brooks will retain the residue parcel as trustee of The Annette Tonkin Brooks Revocable Trust. SURROUNDING LAND USES: North: Tidal marsh, zoned RR, Rural Residential zoning district, with the Nansemond River beyond. East: Wooded and agricultural land zoned RR, Rural Residential zoning district. South: Agricultural land and marsh zoned RR, Rural Residential zoning district. West: Single-family detached dwellings and crop fields zoned RR, Rural Residential zoning district. COMPREHENSIVE PLAN: The City’s 2045 Comprehensive Plan identifies this property as being located within the Northern Growth Area, Traditional Neighborhood Land Use Type. CHESAPEAKE BAY PRESERVATION AREA DESIGNATION: This property is located within the Chesapeake Bay Preservation Area (CBPA) and is designated as a Resource Management Area (RMA) and a Resource Protection Area (RPA). FLOOD PLAIN: The subject parcel is within Flood Zones AE, VE, and X, subject to LiMWA along the northern tidal portion of the property, as shown on Flood Insurance Rate Map (FIRM) Panel No. 5101560038F of the City of Suffolk, Virginia Flood Map dated July 7, 2026. Planning Commission October 20, 2026 FTR2026-00004 Page 2 of 3 CASE HISTORY: Annette Tonkin Brooks transferred the property into the trust by deed recorded on February 25, 2022, as Instrument Number 220002919. Said deed cites Annette Tonkin Brooks, FKA Annette Tonkin Moring as the Grantor. STAFF ANALYSIS ISSUE The subject property, located at 3400 Knotts Neck Road, is owned by The Annette Tonkin Brooks Revocable Trust and is comprised of 17.50 acres from which the trustee, Annette Tonkin Brooks, proposes to subdivide a 1-acre parcel to be conveyed to Timothy Ryan Moring pursuant to Section 31-514 of the Unified Development Ordinance (UDO). The grantee is an immediate family member of the beneficiary of the trust. The Annette Tonkin Brooks Revocable Trust would retain 16.50 acres as the residue parcel. CONSIDERATIONS AND CONCLUSIONS 1. Pursuant to the provisions of Section 31-514(a) of the Unified Development Ordinance (UDO), it is the purpose and intent of a Family Subdivision to keep the family estate within the immediate family and not for the purpose of short-term investment for sale after division to those outside of the immediate family. It is the further intent to provide family members the ability to remain in close proximity as housing needs change, to provide mutual opportunities for support and care of family members, and to allow the preservation of family land holdings which might otherwise be fragmented for economic reasons. 2. Lot dimensions and building setback lines for the proposed new lot are consistent with the RR, Rural Residential zoning district, as set forth in Table 407-1 of the UDO. There is adequate area on the newly proposed lot to allow for the construction of a dwelling and the necessary septic drain field. 3. Pursuant to the provisions of Section 31-514(a) of the UDO and Virginia Code Sections 15.2-2244 (A) and 15.2-2244.2, the property owner has requested a subdivision of property held in trust for the purpose of a gift to member of the immediate family. Timothy Ryan Moring is the son of Annette Tonkin Brooks and is the proposed recipient of the newly created lot. Timothy Ryan Moring has not previously received a family subdivision parcel; therefore, they are eligible for this request. 4. The plat is accompanied by a Deed of Gift conveying fee simple title in the proposed parcel of land with restrictive covenants that prohibit the transfer of the properties within fifteen (15) years of their receipt except in conformity with Section 31-514(e)(4) of the UDO. The deed shall be executed and recorded simultaneously with the plat. 5. Pursuant to the provisions of Section 31-514(c)(3) of the UDO, by sworn affidavit and covenants provided in the Deed of Gift, the Grantee, has acknowledged that the subject lot created under the provisions of the aforesaid section shall be titled only in the name of the immediate family member for whom the subdivision is made for a period of not less than fifteen (15) years. Note that the Grantee may hold title with their spouse during such period. Planning Commission October 20, 2026 FTR2026-00004 Page 3 of 3 6. Pursuant to Section 31-514(c)(3) of the UDO, the Grantor and the Grantee executed a Family Subdivision Sworn Affidavit acknowledging that the transfer of property is not for the purpose of circumventing any section or sections of the UDO, but is instead intended to provide a separate place of residence for the Grantee exclusive of the residence of the Grantor, and is intended to keep the family estate within the immediate family. In the event the Director determines that a Family Subdivision has been used to circumvent the Subdivision Ordinance, the Director shall initiate the vacation of all or part of the plat of the original lot or parcel to the extent necessary to correct the violation. 7. Pursuant to Section 31-514(c)(5) of the UDO, each lot or parcel created by the family subdivision shall front on right-of-way or an ingress and egress easement not less than fifty (50) feet in width shall be provided to new parcel. The Deed of Gift grants a (50) fifty-foot wide ingress and egress easement from a private road owned by Earl E. Tonkin, who has signed the plat for the proposed parcel. 8. Pursuant to Section 31-514(c)(6) of the UDO, an approval letter, dated July 27, 2026, from the City of Suffolk Health Department for the proposed family subdivision parcel as it relates to an on-site septic wastewater system was received. The Health Department noted that the applicant has obtained an approved certification letter for a three-bedroom sewage treatment system located on proposed parcel. A copy of the Health Department letter is attached to this report. RECOMMENDATION Staff finds that this request meets the criteria for a Family Subdivision and the proposed parcel meets all zoning requirements as set forth in the Unified Development Ordinance. Therefore, staff recommends approval of the applicant’s Family Subdivision request, FTR2026-00004, as stated in the attached resolution. Attachments  General Location Map  Zoning/Land Use Map  Family Transfer Affidavit  Deed of Gift to Timothy Ryan Moring  Health Department Letter  Resolution  Exhibit A – Family Subdivision Plat COMMONWEALTH OF VIRGINIA WESTERN TIDEWATER ENVIRONMENTAL HEALTH DISTRICT SUFFOLK HEALTH DEPARTMENT 135 Hall Avenue, Suite A SUFFOLK, VIRGINIA 23434 757-514-4751 Subdivision Approval Recommended July 27, 2026 Planning Department City of Suffolk P.O. Box 1858 Suffolk, Virginia 23439-1858 RE: Planning File #: FTR 2026-00004 Project Address: 3400 Knotts Neck Road, Suffolk, VA 23435 Tax Map: 5*33A Account Number: 303685000 On July 21, 2026 the Suffolk Health Department received a request from you to review the proposed lot in the referred subdivision for onsite wastewater system approvals for first submittal. This letter is to inform you that the above referenced subdivision plat is approved for individual onsite wastewater systems in accordance with the provisions of the Code of Virginia, the Sewage Handling and Disposal Regulations , and the Private well regulations (12VAC5-610-20 et. seq., the Regulations) (12VAC5-630-30 et. seq.,) This request for subdivision review was submitted pursuant to the provisions of §32.163.5 of the Code of Virginia which requires the Virginia Department of Health to accept private soil evaluations and designs from a licensed Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation with an OSE for residential development. This subdivision was certified as being in compliance with the Boa rd of Health’s regulations by: Adam Herman, AOSE. The Suffolk Health Department has an approved certification letter for a three-bedroom sewage treatment system located on proposed parcel 5*33A*1 (1.00 acres). Approved Health Department certification letter is attached. If you have any questions, please contact me at (757) 514-4758, or by email at Bethany.Kenny@vdh.virginia.gov. Sincerely, Bethany M. Kenny Bethany Kenny Environmental Health Specialist, Sr. Suffolk Health Department Cc: Adam Herman-OSE Note: If the approved sewage system sites are not shown on the record plat, they must be shown on a separate plat on file in the local health department. The plat showing the sewage system sites must be reconciled with the record plat. RESOLUTION NO. 26-10-01 CITY OF SUFFOLK PLANNING COMMISSION A RESOLUTION APPROVING A FAMILY SUBDIVISION ON PROPERTY LOCATED AT 3400 KNOTTS NECK ROAD, ZONING MAP 5, PARCEL 33A, ACCOUNT NUMBER 303685000; FTR2026-00004 WHEREAS, Annette Tonkin Brooks, applicant, on behalf of The Annette Tonkin Brooks Revocable Trust, property owner, submitted an application for a Family Subdivision for review pursuant to the provisions of Section 31-514 of the Unified Development Ordinance (UDO) of the City of Suffolk, which plat is attached hereto as Exhibit “A” and incorporated herein and hereafter referred to as the Plat; and WHEREAS, this specific request is to grant permission under Section 31-514 of the Unified Development Ordinance for a transfer of property to an immediate family member to hold title to the subject property for a period of not less than fifteen (15) years from the date of recording of the Plat; WHEREAS, the procedural requirements for the consideration of this request by the Planning Commission have been met. NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Suffolk, Virginia, that: Section 1. Findings. The Suffolk Planning Commission: ___ a. Finds, ___ b. Does not find, (1) Granting this Family Subdivision will be for the purpose of providing separate places of residence to an immediate family member over the age of eighteen (18) years old for a period of fifteen (15) years; (2) This Family Transfer Subdivision is not created to circumvent the subdivision ordinance; (3) Lot dimensions and building setbacks for the lot created by this Family Subdivision will be consistent with the Rural Residential zoning district as set forth in Table 407-1 of the City of Suffolk UDO. (4) The proposed parcel has received Health Department approval for a septic system as noted on the plat. (5) The Family Subdivision Affidavit has been executed by the Grantor and the Grantee. The Deed of Gift for this Family Transfer shall be executed and recorded simultaneously with the plat. READ AND ADOPTED: ___________________ TESTE: __________________________________ STAFF REPORT DESCRIPTION ORDINANCE TEXT AMENDMENT O TA2026-010: Presented for your consideration are proposed amendments to Sections 31-604(e), 31-604(h), 31-605(b), 31-606 (a), 31 -606(c), 31 - 612(p), 31-612(k), 31-701, 31-708(a), 31-801(e), and Appendix B, of the Unified Development Ordinance, Chapter 31 of the Code of the City of Suffolk . The purpose of the proposed text amendment is to update and refine the Unified Development Ordinance due to a change in circumstance. APPLICANT: The proposed ordinance text amendment has been initiated by the City of Suffolk. PUBLIC NOTICE: This request has been duly advertised in accordance with the public notice requirements set forth in Section 15.2-2204 of the Code of Virginia, as amended, and with the applicable provisions of the Unified Development Ordinance. STAFF ANALYSIS ISSUE AND BACKGROUND This application contains a series of proposed amendments to the Unified Development Ordinance (UDO) prepared by staff and are intended to address several areas where changes have been recommended for consideration in response to questions or concerns that have arisen in the context of the day -to-day administration of the UDO. The proposed changes update and clarify code language and fix discrepancies within the UDO, as summarized in this report. This material in this application was discussed by the Committee on Ordinances at its August 19, 2026 meeting. Following the meeting, the initial application was divided into two separate applications due to the volume of material, in order the ensure Planning Commission, City Council, and the public can adequately review the proposed amendments. Therefore, this application functions as Part 2 of “General Housekeeping” text amendments to the UDO. Each Article of the UDO proposed to be modified with this particular application is listed, with changes to specific sections in each Article detailed below; SUMMARY AND EXPLANATION OF PROPOSED TEXT AMENDMENTS Article 6, Design and Improvement Standards Section 31-604, Lighting This section establishes standards for public streetlights in Suffolk. Public streetlights are installed and maintained by Dominion Energy, and as of 2022, Dominion has shifted to only installing LED fixtures in new streetlights. The current streetlight standards in this section are outdated and lack any reference to LEDs. Therefore, in Table 604-1, Shielding Requirements, a new row is added for LED fixtures , requiring fully shielded fixtures to prevent light pollution. The footnote 1 reference is struck from the low-pressure sodium row, shifting the “preferred light source” to LED, Planning Commission October 20, 2026 OTA2026-010 Page 2 of 4 as low-pressure sodium lamps are now more difficult to obtain and install. Footnote 5, which lists preferred lamp colors, is proposed to be amended to add LED fixtures with a color -corrected temperature of 4,000 Kelvin , matching the current color temperature for streetlights in Public Works’ Public Facilities Manual. In subsection (e)(1), the light ing standard is restated as a minimum light output of 5,000 lumens rather than a minimum “lamp size” (LED fixtures are not traditional lamps) and the exception is triggered by the need for a “brighter light fixture ” rather than a “larger size lamp ”. New subsection (e)(3) is proposed to require streetlight fixtures to be installed with a Type II or Type III light distribution pattern , in accordance with the Public Facilities Manual. Section 31-605, Lot Layout Standards This section is proposed to be modified to require that the 100-foot Resource Protection Area (RPA) buffer can no longer be located on new individual residential lots with less than 10,000 square feet of buildable area platted as part of a major subdivision. For major subdivisions with small lots, RPA buffer area must now be located within common open space , unless a lot with RPA located on it contains 10,000 square feet or more buildable area, so as to not eliminate the possibility of creating waterfront lots in major subdivisions where appropriate . Since many new major subdivisions are subdivided in a cluster form with smaller lots, it is not particularly desirable to create a small parcel where significant portions of land (or, in actual cases, the entirety of a rear yard) are located within protected RPA , and the proposed regulation will help reduce accidental encroachment violations by individual homeowners who disturb protected buffers. RPA being located in common open space under the ownership of a property owners ’ association also has facilitates more centralized management and shifts CBPA compliance to that collective entity, as opposed to each individual property owner. Section 31-606, Parking and Loading Standards Staff has proposed amendments to clarify minimum off-street parking dimensional standards and to provide provisions for alternative parking solutions. Table 606 -3, Parking Dimensions, is proposed to be amended, retaining the existing one-way and two-way aisle widths by parking angle and adding minimum stall width and stall length columns for standard spaces (8 feet by 20 feet at 0–44 degrees; 9 feet by 19 feet at 45–59 degrees; 9 feet by 20 feet at 60–74 degrees; 9 feet by 18 feet at 75–90 degrees), plus new compact space provisions (eight-foot widths with lengths of 18 feet, 17 feet, 18 feet, and 16 feet across the same angle ranges noted prior), subject to a new footnote allowing up to 25 percent of required spaces to be compact and requiring them to be marked “Compact Cars Only ”. Subsection (a)(9)(H) is rewritten so that accessible parking is provided and labeled per the numerical and design standards of the Virginia Uniform Statewide Building Code and the Americans with Disabilities Act of 1990; the paragraph directing applicants to specific federal technical assistance manual web addresses are proposed to be removed since the website addresses are outdated and subject to frequent change . Section 31-606(a)(9)(I) establishes minimum dimensions of 4 feet by 8 feet for designated motorcycle or motor scooter spaces, which must be clearly marked. In the provision on parking and storage of certain vehicles, staff has proposed an addition to subsection (c)(2); a prohibition on parking commercial trailers or semi-trailers parallel and outside a marked space within designated drive aisles serving a development in any zoning district. This is to prevent access conflicts within developments. Planning Commission October 20, 2026 OTA2026-010 Page 3 of 4 Section 31-612, Street Improvement Standards A minor addition is proposed to this section to standardize the abbreviations used for street name suffixes (e.g., clarifying Circle is abbreviated as CIR), and to add Avenue and Way to codified list of acceptable street suffixes. A typo in 612(k)(3) has also been corrected. Article 7 - Supplemental Use Regulations Section 31-701, Accessory Uses and Structures Staff has proposed minor “clean-up” changes to the supplemental standards for accessory uses. In subsection (a), fences are carved out of the rule barring accessory buildings before commencement of construction the principal building, by cross-reference to subsection (d). In subsection (b)(10), the fence provision is amended to clarify that it applies to single-family residential uses. Staff has also proposed language in this same subsection to permit fences or walls six feet in height in side or rear yards abutting a street where the established setback exceeds the district minimum. • Section 31-701(b)(18), Family Day Homes: While the supplemental standards for family day homes for 5-12 children (which are only permitted by CUP) establish certain operating hours from 6 AM to 8 PM, City Council has often allows an exception permitting alternate hours of operation, such as overnight care. A provision is proposed to be added that codifies City Council’s ability to approve alternate hours of operation on a case-by-case basis. The proposed amendments to the section update the licensing agency from the Virginia Department of Social Services to the Virginia Department of Education or other state agencies as required by the Code of Virginia. • Section 31-701(d), Fences: Staff propose s to expand the introductory language to reference requirements set forth for specific zoning districts and uses in the prior subsections. Two new provisions are proposed as well; subsection (3) permits fences on a lot without a principal structure, provided such a fence or wall is no more than fifty percent (50%) opaque and complies with the height limits of Sections 31-701(b) and (c) , and subsection (4) permits fences in the Agricultural district , in conjunction with a bona fide agricultural operation, up to eight feet in height in any yard. Section 31-708, Junkyards/Automobile Graveyards, Storage Yards, and Scrap Metal Processing Yards The applicability provision is expanded to cover outdoor heavy equipment and industrial storage lots. This section covers these uses, but this is not enumerated clearly in the applicability provision. Article 8 - Nonconforming Uses Section 31-801, Nonconforming Lots of Record Staff has proposed a modification of Section 31-801(e)(1)(A)(ii), which contains specifics for side yard setbacks for nonconforming lots, in response to a high er volume of builders wishing to construct homes on existing infill lots in the City. The provision is proposed to be clarified to apply to new single -family detached or semi -attached construction on a nonconforming lot of record , Planning Commission October 20, 2026 OTA2026-010 Page 4 of 4 allowing the administrative approval of reduced side setbacks to five feet for any nonconforming lot of record thirty (30) feet or less in width (where not adjacent to a public right-of-way). Appendix B Appendix B, which contains submittal requirements for site plans, subdivision engineering plans, and plats, is somewhat outdated due to advances in technology and changing regulations elsewhere in the UDO. • Section B-1: A reference to maintaining forms at “and at the office of Zoning Administrator” is deleted, since the Zoning Administrator works within the Department of Planning and Community Development. In the list of application types, several items have been updated to reference current terminology. • Section B-2: Several updates to the Table of Submittal Requirements are proposed to add material or information that is already required in practice due to updated regulations elsewhere in the UDO and in State Code. • Sections B-8(a), B -9(b), and B -10: These subsections contain requirements for plan copies. Across all three sections, the required number of submittal copies is reduced from fifteen to three, and the specification for “blue or black line” prints is replaced with a requirement that copies be printed in black ink, given blue -line prints are no longer commonly produced. RECOMMENDATION The Unified Development Ordinance , like all zoning and subdivision codes within the Commonwealth, is updated from time to time to ensure regulations are effective and accurate. The attached ordinance text amendments, which represent the second part of a larger “housekeeping” effort, are proposed to keep Suffolk’s UDO current by clarifying regulations and updating outdated sections. Therefore, staff recommends that the Planning Commission forward the amendments as proposed within Exhibit “B” to City Council with a recommendation of approval. Attachments • Proposed Ordinance • Exhibit A – Planning Commission Recommendation • Exhibit B – “Amendments to Sections 31-604(e), 31-604(h), 31-605(b), 31-606 (a), 31 - 606(c), 31-612(p), 31-612(k), 31-701, 31-708(a), 31-801(e), and Appendix B of Unified Development Ordinance” ORDINANCE NUMBER AN ORDINANCE TO AMEND SECTIONS 31- 604(E), 31- 604(H), 31- 605(B), 31-606 (A), 31- 606(C), 31-612(P), 31-612(K), 31-701, 31-708(A), 31- 801(E), AND APPENDIX B , OF THE UNIFIED DEVELOPMENT ORDINANCE OF THE CITY OF SUFFOLK, VIRGINIA; OTA2026-010 WHEREAS, the City of Suffolk, Virginia has initiated the aforementioned amendments to the Code of the City of Suffolk Unified Development Ordinance for the purpose of updating and improving clarity and consistency due to a change in circumstances; and, WHEREAS, the specified amendments to the Unified Development Ordinance as shown in Exhibit “B” are in compliance with the 2045 Comprehensive Plan, as adopted; and, WHEREAS, the Planning Commission has made a recommendation as stated in Exhibit "A"; and, WHEREAS, the procedural requirements for the consideration of this request by the Planning Commission have been met. NOW, THEREFORE, BE IT ORDAINED by the Council of the City of Suffolk, Virginia, that: Section 1. Exhibit “B,” “Amendments to Sections 31-604(e), 31-604(h), 31-605(b), 31- 606 (a), 31- 606(c), 31-612(p), 31-612(k), 31-701, 31-708(a), 31-801(e ), and Appendix B, of the Unified Development Ordinance of the City of Suffolk, Virginia which is attached hereto, is hereby incorporated as part of this ordinance. Section 2. Unified Development Ordinance Sections 31-604(e), 31-604(h), 31-605(b), 31-606 (a), 31- 606(c), 31-612(p), 31-612(k), 31-701, 31-708(a), 31 -801(e), and Appendix B, are hereby amended to read as referenced in Exhibit “B”. Section 3. All phrases, clauses, sentences, paragraphs, subsections, sections and chapters of the Code not amended hereby remain in full force and effect. This ordinance shall be effective upon passage and shall not be published. READ AND PASSED: TESTE: Erika S. Dawley, City Clerk Approved as to Form: _________________________________ William E. Hutchings, Jr., City Attorney Exhibit “A” RESOLUTION NO. 26-10-02 CITY OF SUFFOLK PLANNING COMMISSION A RESOLUTION TO PRESENT A REPORT AND RECOMMENDATION TO CITY COUNCIL RELATING TO OTA2026-010 AN ORDINANCE TO AMEND SECTIONS 31-604(E), 31-604(H), 31-605(B), 31-606 (A), 31- 606(C), 31-612(P), 31-612(K), 31-701, 31-708(A), 31-801(E), AND APPENDIX B OF THE UNIFIED DEVELOPMENT ORDINANCE OF THE CITY OF SUFFOLK, VIRGINIA WHEREAS, the City of Suffolk, Virginia has initiated the aforementioned amendments to Chapter 31 of the Unified Development Ordinance for the purpose of updating and improving clarity and consistency due to a change in circumstances; and WHEREAS, the specified amendments to the Unified Development Ordinance as shown in Exhibit “B” are in compliance with the 2045 Comprehensive Plan, as adopted; and WHEREAS, the procedural requirements for the consideration of this request by the Planning Commission have been met. NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Suffolk, Virginia, that: Section 1. Findings. The Suffolk Planning Commission finds that the proposed ordinance amendments are reasonable and warranted. Section 2. Recommendation to City Council. The Planning Commission recommends to the City Council of the City of Suffolk, Virginia that the proposed amendments be; _____a. Adopted as submitted without modification. _____b. Denied, and that Council not pass the proposed ordinance. _____c. Adopted with the modifications set forth on the attached listing of specific recommendations, and that Council adopt the proposed Ordinance with such modifications. READ AND ADOPTED: TESTE: “Exhibit B” “Amendments to Sections 31-604(e), 31-604(h), 31-605(b), 31-606 (a), 31-606(c), 31-612(p), 31-612(k), 31-701, 31-708(a), 31-801(e), and Appendix B, of the Unified Development Ordinance of the City of Suffolk, Virginia” ARTICLE 6 – DESIGN AND IMPROVEMENT STANDARDS … SEC. 31-604. LIGHTING. … (e) STREET LIGHTS. Street lights shall be installed by the Applicant for approval of any major subdivision, as defined by Article 5 of this Ordinance. The applicant shall design the proposed street lighting system in accordance with the criteria set forth in Subsections (1) and (2), below, and furnish payment equal to all applicable installation costs and first seven years' rental charge for such system. Funds necessary to pay these costs shall be deposited with the City prior to final plat approval. Said street lights shall comply with the following standards: (1) Street lights shall have a minimum light output of size of 5,000 lumens, unless a brighter light fixture larger size lamp is needed for highway safety purposes and/or road intersections, as determined by the Director of Public Works. (2) Street light poles shall be designed so as to be placed in accordance with VDOT or City standards. Placement of the street light poles shall be on or near side property lines. (3) Street light fixtures shall be installed with a Type II or Type III light distribution pattern. … (h) MEASUREMENT. … TABLE 604-1: SHIELDING REQUIREMENTS Fixture Lamp Type Shielded Filtered Light Emitting Diode (LED) 1, 7 Fully5 None Low Pressure Sodium1 No None High Pressure Sodium Fully None Metal Halide Fully2,6 Yes Fluorescent Fully3,5 Yes Quartz4 Fully No Incandescent, Greater than 150W Fully None Incandescent, 150W or Less None None Fossil Fuel None None Glass Tubes filled with Neon, Argon, Krypton None None NOTES: 1 This is the preferred light source to minimize undesirable light emission into the night sky affecting astronomical observations. 2 Metal halide lighting used primarily for display purposes shall not be used for security lighting after 11:00 p.m. Metal halide lamps shall be installed only in enclosed luminaries. 3 Outdoor advertising signs of the type constructed of translucent materials and wholly illuminated from within do not require shielding. Dark backgrounds with light lettering or symbols are preferred, to minimize detrimental effects. Unless conforming to the above dark background preference, total lamp wattage per property shall be less than 41 Watts in Area A. 4 For the purposes of this Code, quartz lamps shall not be considered an incandescent light source. 5 Warm white and natural lamps, or LED fixtures with a color corrected temperature of 4,000 Kelvin, shall be installed are preferred to minimize detrimental effects. 6 Metal halide fixture lamp types shall be filtered. "Filtered" means any outdoor light fixture which has a glass, acrylic or translucent enclosure of the light source (quartz glass does not meet this requirement). … SEC. 31-605. LOT LAYOUT STANDARDS. … (b) MINIMUM LOT STANDARDS. … (11) Any newly created residential lot with less than 10,000 square feet of buildable area that is platted and recorded as part of a major residential subdivision shall not contain or be located, in whole or in part, within land area designated as Resource Protection Area (RPA) as defined in Section 31-415.1, CHESAPEAKE BAY PRESERVATION OVERLAY DISTRICT (CB), of this Ordinance. Such land area within a major subdivision shall be considered as passive open space under common ownership, unless located on a lot that contains buildable area equal to or larger than 10,000 square feet in size. The provisions of this section only apply to newly created residential lots within a major subdivision. Nothing in this section shall be construed to supersede the development regulations and restrictions contained within Section 31-415.1. … SEC. 31-606. PARKING AND LOADING STANDARDS. (a) OFF-STREET PARKING. … (9) PARKING STALL AND AISLE DIMENSIONS AND SPECIFICATIONS. Parking stall and aisle dimensions shall comply with the following standards: … C. Off-street parking spaces and drive aisles shall comply with the have a minimum dimensional standards established below, stall width of nine feet and a minimum stall length of eighteen (18) feet unless otherwise permitted or required by this Ordinance: Minimum aisle width for parking areas shall be in accordance with the following: TABLE 606-3: PARKING DIMENSIONS Parking Angle Aisle Width (Degrees) Minimum One- Way Aisle Width (Feet) Minimum Two- Way Aisle Width (Feet) Minimum Stall Width (Feet) Minium Stall Length (Feet) Standard Spaces 0—44 12 24 8 20 45—59 14 24 9 19 60—74 18 24 9 20 75—90 24 24 9 18 Compact Spaces* 0—44 12 24 8 18 45—59 14 24 8 17 60—74 18 24 8 18 75—90 24 24 8 16 * Up to 25 percent of all required parking spaces may be compact spaces. All compact spaces must be clearly marked for "Compact Cars Only." H. Parking spaces for handicapped or disabled persons shall be provided and labeled in accordance with the numerical and design standards established by the Virginia Uniform Statewide Building Code and as specified in shall comply with, the Americans with Disabilities Act of 1990.(42 U.S.C § 12181 ET SEQ., Pub. L. 101- 336, and implementing regulations at 28 C.F.R. parts 35 and 36). Applicants should consult the ADA Technical Assistance Manual for Small Businesses available from the United States Department of Justice on the Internet at http://www.usdoj.gov/crt/ada/taman3.html, and the Technical Assistance Manual for State and Local Governments at http://www.usdoj.gov/crt/ada/taman2.html. I. Designated motorcycle spaces that are designed to accommodate motorcycles or motor scooters shall have minimum dimensions of four (4) by eight (8) feet and shall be clearly marked as motorcycle spaces. JI. Except where a wall is required, a minimum six (6) inch high vertical concrete curb shall be constructed so that no part of a vehicle extends beyond the property line or into pedestrian access areas and sidewalks. … (c) P ARKING AND/OR STORAGE OF CERTAIN VEHICLES PROHIBITED IN SPECIFIC DISTRICTS. … (2) A commercial trailer or semi-trailer shall not be parked or stored in any residential or B-1 commercial district except in an enclosed building. Commercial trailers or semi- trailers shall not be parked parallel, outside of a marked parking space, within the designated drive-aisles serving a development within any zoning district. This Section shall not be interpreted to prohibit commercial trailers or semitrailers from loading and unloading for not more than 24 hours in any such district. … SEC. 31-612. STREET IMPROVEMENT STANDARDS … (p) STREET IDENTIFICATION SYSTEM. … (2) Streets within the classifications set forth above may be designated according to the following terms and abbreviations defined in this Section: A. Boulevard (BLVD). B. Circle (CIR). C. Court (CT). D. Drive (DR). E. Lane (LN). F. Parkway (PKWY). G. Place (PL). H. Road (RD). I. Street (ST). J. Avenue (AVE) K. Way (WAY) … (k) ACCELERATION, DECELERATION AND TURNING LANES. Acceleration, deceleration, and turning lanes shall be required by the decisionmaker along existing or proposed streets for all subdivisions or site plans under the following conditions and in accordance with the PFM: (1) Roadway classification of arterial or major collector; or (2) Roadways with a posted speed limit of 45 mph or higher; or (3) Proposed development generates at least 30 vehicles per hour (VPH) mph at a single entrance. Accident history, pedestrian conflicts, and existing capacity may also be factors in det ermining the need for a turn lane. In addition, arterials, collectors, sub- collectors, special corridor overlays and all commercial and major residential subdivisions shall have left and right turn lanes installed regardless of generated volumes as determined by the Department of Public Works. … ARTICLE 7 - SUPPLEMENTAL USE REGULATIONS … SEC. 31-701. ACCESSORY USES AND STRUCTURES. (a) GENERALLY. Unless otherwise provided herein, accessory uses and structures shall be permitted in any zoning district, but only in connection with, incidental to, and on the same lot with a principal use or structure which is lawfully permitted within such district. Accessory buildings or uses, excepting fences as provided in Subsection (d) of this Section, shall not be constructed or established on a lot until construction of the principal building has been actually commenced or the primary use established. Accessory buildings shall not be used for dwelling purposes, except as provided in Subsection (b) of this Section. (b) ACCESSORY USES PERMITTED IN CONJUNCTION WITH RESIDENTIAL U SES. The following accessory uses shall be permitted in conjunction with residential uses: … (10) Fences or walls in single-family residential uses, districts provided that: A. A fence or wall not more than six (6) feet in height may be located in any required side yard or rear yard other than a required yard adjacent to a street, however, fence or wall six (6) feet in height may be located in a side or rear yard abutting a street with an established setback in excess of the district minimum. A fence or wall not more than six (6) feet in height may be located in any planting screen/no access easement adjacent to a street serving a double frontage and/or reverse frontage lot. Except as allowed above, no fence or wall which creates a solid screen may exceed two and one-half (2½) feet in height in any required yard adjacent to a street, except that fences having a uniform open area of fifty percent (50%) or more may be erected to a maximum height of four (4) feet in such required yards. Height shall be measured from the average ground level adjacent to the fence or wall. No fence or wall shall encroach the visibility triangle. … (18) Family day homes providing care for not fewer than five (5) but not more than twelve (12) children under the age of thirteen (13), exclusive of the provider's own children and any children who reside in the home, where permitted pursuant to Section 31-406 of this Ordinance, shall not be established except in accordance with the following criteria: … A. Each family day home shall be located within a single- family detached structure. B. Hours of operation. Family day homes shall be limited to operation between the hours of 6:00 a.m. and 8:00 p.m., unless alternate hours of operation are otherwise approved by City Council as part of the approval of a Conditional Use Permit. C. Indoor space. Family day homes shall comply with the American Academy of Pediatrics and the American Public Health Association recommendation to provide thirty-five (35) square feet of indoor space per child which is free of furniture and equipment, or fifty (50) square feet of space if furniture and equipment are included. D. Fenced play areas. A fenced play area of not less than one thousand (1,000) square feet shall be provided. Such play areas shall be so located as to provide maximum peace and tranquility to adjoining residential uses and to protect the safety of the children. Outdoor play activities on the premises shall be conducted within the fenced play area, and such activities shall be limited to the hours of 8:00 a.m. and 6:00 p.m. E. Traffic. The additional traffic generated by a family day home, excluding trips associated with the dwelling unit, shall not exceed twenty-four (24) vehicle round trips per day. For the purposes of this section, a "vehicle round trip" means one vehicle entering and exiting the site. F. Parking. In addition to the required parking for a residential use, each family day home shall provide a minimum of one (1) parking space plus one (1) parking space for each additional employee. The parking spaces shall be located on-site or on-street where provided by law. On-street parking shall be located no further than two hundred (200) feet from the property. G. State licensure. Each family day home shall acquire and maintain licensure from the Virginia Department of Education Social Services or other state agency as required by the Code of Virginia. The owner or operator shall provide a copy of the license to the zoning administrator. The owner or operator's failure to provide a copy of the license to the Zoning Administrator shall be deemed to be willful noncompliance with the provisions of this chapter. H. Inspections by fire official. The Suffolk Fire Marshal is authorized to conduct periodic inspections of the family day home. The owner or operator's failure to promptly admit the fire official onto the premises and into the dwelling unit to conduct an inspection in a manner authorized by law shall be deemed to be willful noncompliance with the provisions of this chapter. I. Zoning permit and annual review . No family day home shall commence without a first obtaining a zoning permit. The Zoning Administrator shall review the permitted use for compliance on an annual basis. J. Relationship to other laws. The provisions of this section are supplementary to a ll other laws and nothing herein shall be deemed to preclude application of the requirements of the Virginia Department of Social Services. Virginia Department of Health. Virginia State Fire Marshal, or any other local, state or federal agency. … (d) F ENCES. Fences in all zoning districts shall comply with the following requirements, in addition to those set forth for specific zoning districts and uses in the subsections above: (1) The height of fences shall be determined by measurement from the ground level at all points upon which the fence is located. An increase in height shall be allowed when spacing for drainage under the fence is needed. (2) The height and location requirements of this Section may be modified as part of a subdivision, planned development, or conditional use approval. For fences on retaining walls, see definition of a retaining wall. (3) Fences shall be permitted to be installed on any lot without the prior establishment of a principal structure, provided that any fence or wall installed on such a lot in accordance with this provision shall not be more than fifty percent (50%) opaque and shall be installed at a height in accordance with the provisions of subsections (b) and (c) of this Section. (4) Fences may be installed in the Agricultural zoning district in conjunction with a bona-fide agricultural operation and shall be no more than eight (8) feet in height in any required front, side, or rear yard. This standard shall not be deemed to prohibit any fences or walls which may be required for screening, security or safety purposes by the Zoning Administrator. … SEC. 31-708. JUNKYARDS/AUTOMOBILE GRAVEYARDS, STORAGE YARDS AND SCRAP METAL PROCESSING YARDS. (a) APPLICABILITY. This Section shall apply to any automobile graveyard, automobile storage yard, junkyard and scrap metal processing yard, as defined in Section 18-31 of the City Code and this Ordinance. This section shall also apply to outdoor heavy equipment and industrial storage lots. … ARTICLE 8 – NONCONFORMING USES. … SEC. 31-801. INTENT. … (e) NONCONFORMING LOTS OF RECORD. (1) SINGLE NONCONFORMING LOTS OF RECORD. Permitted uses in any district may be allowed on any single lot of record at the effective date of adoption or amendment of this chapter, notwithstanding limitations imposed by other provisions of this chapter. Nonconforming lots created by judicial partition after the effective date of this chapter shall be eligible for a building permit if they meet the requirements of Section 31-801(e)(1)B except the ability of the Administrator or Board of Zoning Appeals to authorize a modification shall include minimum lot size and lot width. Such lot must be the subject of an approved resubdivision in accordance with Article 8, Section 31-801(e)(2), Nonconforming Lots of Record with Common Frontage below. The dimensional and density requirements established in Article 4, Section 31-407, Dimensional and Density Regulations shall apply even though such lot fails to meet the requirements for lot area or lot width, or both, generally applicable in the underlying zoning district except as provided for as follows: A. Within the RL, RLM, RM, RC, and RU zoning districts the Zoning Administrator may authorize or require an adjustment to and reestablishment of the minimum and maximum (if applicable) required front and side yard setbacks as follows: … (ii) SIDE YARD SETBACK. The side yard setback of new single family detached or semi-attached construction on a non-conforming lot of record shall be as generally applicable for the underlying zoning district and may be reduced adjusted and reestablished to a distance not to exceed a modification of thirty percent (30%) of the generally applicable required side yard setback, however, any non-conforming lot of record thirty (30) feet or less in width, and where not adjacent to a public right-of-way, shall be permitted to have a side yard setback reduction to no less than five (5) feet; … APPENDIX B - SUBMISSION REQUIREMENTS … B-1. SPECIFICATIONS FOR DOCUMENTS TO BE SUBMITTED. (a) FORMS. T he Director and Administrator, as appropriate, shall promulgate submittal requirements, instructions for completing forms, and internal procedures for acceptance and filing of applications. Additional information may be required for particular applications. Necessary forms shall be prepared for the administration, interpretation and enforcement of this Ordinance and shall be maintained at the offices of the Planning and Community Development Department and the office of Zoning Administrator, as appropriate, including: (1) Application for Comprehensive General P lan Amendment - General Plan Land Use Map. (2) Application for Rezoning. (3) PreaApplication for Preliminary Subdivision and Site Plan Approval Site Plan Approval. (4) Application for Final Site Plan Approval. (5) Application for Final Subdivision Plat Approval. (6) Application for Conditional Use Permit Approval. (7) Application for Specific Plan Approval. (8) Application for Zoning Variance. (9) Application for Subdivision Variance. (10) Notice of Appeal to the Board of Zoning Appeals. … B-2. TABLE OF SUBMITTAL REQUIREMENTS. … APPENDIX (TABLE B-2): SUBMITTAL REQUIREMENTS (A) Material/Information (B) (C) (D) (E) (F) Preliminary Site Plan Preliminary Subdivision Plat Final Site Plan Final Subdivision Plat Subdivision Engineering Plans Title and/or Signature Blocks; Introductory Materials: Type of development. * * * * * Graphic and written scale and date of preparation. * * * * * North arrow. * * * * * Notarized signature of property owner or agent of landowner. * Date of preparation, including dates and descriptions of all revisions. * * * * * Signature blocks prepared for the dated signatures of the Director and other required signatories. * * * * * Certification statement endorsed by a licensed professional engineer or surveyor stating as follows I hereby certify that this subdivision was made by me at the direction of the owner and that this subdivision is entirely within the boundaries of land owned by him/her and that steel pins, as shown on this plat by small circles, have actually been placed and their locations correctly shown and that the plat details meet the standards for plats as adopted under VC §42.1-82 of the Virginia Public Records Act (§ 42.1-76, et. seq.). ___________ ___________ Date Name * Certification by an engineer, architect, land surveyor or landscape architect licensed to practice in Virginia. No person shall prepare or certify design elements which are outside the * * * * limits of their professional expertise and license. The seal and signature of the Virginia registered professional engineer, land surveyor, landscape architect or architect responsible for its preparation shall be provided on each sheet. Certification statement endorsed by the signing agent for the City of Suffolk stating as follows: The undersigned certify that this subdivision, as it appears on this plat, conforms to the applicable regulations relating to the subdivision of land and is accordingly approved. By such approval, the undersigned do not certify as to the correctness of the streets, boundaries, or other lines as shown on this plat. ___________ ___________ Date Agent, City of Suffolk ___________ ___________ Date Agent, City of Suffolk * Name and address, including telephone number, of the professional person(s) responsible for subdivision or site plan design, for the design of public improvements, and for surveys. * * * * * A general information Section indicating the number of sheets, and an index showing the locations of the various sheets. If the site plan or subdivision plat is shown on more than one sheet, match lines shall clearly indicate where the several sheets join and an index shall be shown locating the sheets. * * * * * All associated Rezoning proffers, conditional use permit conditions, wetlands permits and waivers or variances granted shall be referenced by with both application number, and resolution or Ordinance number, and, if appliable, the recording instrument number noted. * * * * * The zoning of the parcel property, tax parcel number(s), account number(s), and addresses. * * * * * Table of statistical information, including: • Total area of the property (acres and square feet). * * * * * • Area and percentage of total of existing buildings. * * • Area and percentage of total of proposed buildings. * * • Total number of dwelling units or lots, by development phase * * * * * • Residential density and units per acre. * * * * * • Total floor area and floor area ratio for each type of use. * * • Total area in landscaping, buffers or open space. * * * * * • Total area in active and passive recreational open space. * * * * * • Total area in critical areas. * * * * * • Total number of off-street parking and loading spaces (required and provided). * * • Area and percentage of total of impervious surfaces. * * * • Surface area and percentage of total lot area of parking and loading areas. * * • Setbacks for the applicable zoning district and any overlay district * * * * * • Current and proposed use of the property * * * * • Average lot size * * * • Street connectivity ratio * * A blank space four inches by six inches (4" x 6") in size reserved for the use of the City on the lower right hand corner of the title sheet. * * * * * Name: Name of subdivision if property is within an existing subdivision. * * * * * Proposed name of subdivision or development if not within a previously platted subdivision. The proposed name shall not duplicate the name of any plat previously recorded in the City of Suffolk. * * * * * Name of property if no subdivision name has been chosen. * * * * * Ownership: Name and address, including telephone number, of legal owner or agent of property, and citation of last instrument conveying title to each parcel of property involved in the proposed development, giving grantor, grantee, date and land records reference. * * * * * Certification statement of the owner(s consent and dedication duly acknowledged before a licensed notary public. This statement shall read as follows: This subdivision of property, as it appears on this plat, is with the free consent and in accordance with the desires of the undersigned owner(s), who also dedicate the streets to the City of Suffolk and agree to comply with all requirements of the subdivision Ordinance prior to their acceptance by the City or the Virginia Department of Transportation. ___________ ___________ Date Owner ___________ ___________ Date Owner * Description and location of all existing easements, rights-of-way or covenants, including those contiguous to the development area, their nature, width, and the instrument book and page number of their recording in the City's land records. * * * * * The owners, tax parcel numbers, addresses, account numbers, and present zoning, present use, and instrument number of the most recent deed of conveyance, of all abutting or contiguous parcels. * * * * * Legal Description: Location map with minimum scale of one inch equals two thousand feet (1″=2000′). * * * * * The boundaries of the property by bearings and distances, which shall be tied to the City geodetic control network, including both horizontal and vertical control. * * * * * Location of property by the Virginia State Plane Coordinate System (HARN - South Zone). * * * * All vertical elevations shall be based on the City's vertical datum, which is NAVD 88. * * * * A legal description and accompanying map exhibit of the property at a scale of one inch equals one hundred feet (1″ = 100 feet) showing the location and type of boundary evidenced. The description may be related to the Virginia State Plane (South Zone) Coordinate System, if the two adjacent corners are shown. * * * Such information shall be provided from the recorded plats. The legal description shall include the following data: • Metes and bounds of all property lines; • Total area of property; • Scale and north arrow; and • Name and route numbers of boundary streets and the width of existing right(s)-of-way. The exterior boundaries of the development area giving lengths and bearings of the boundary lines, including the nearest benchmark or improvement. If the proposed development is bounded by a watercourse, a closing meander traverse of that boundary shall be made and shown on the site plan or subdivision plat. Where curving boundaries are used, sufficient data to establish the boundary on the ground shall be given; including the radius, central angle, and arc length of the curve. * * * * * Benchmark information, including the basis of bearings used and a north point. * * * * * Geometric location data for all public rights-of-way, geographic control monuments, common areas, utility centerlines and easements, structures and lot lines. * * * * All monuments erected, corners, and other points established in the field in their proper places. The material of which the monuments, corners, or other points are made shall be noted at the representation thereof or by legend. The legend for metal monuments shall indicate the kind of metal, the diameter and length of the monuments. Include all existing monuments found during the course of the survey (including a physical description such as "brass cap", "rebar," "concrete," etc.), including appropriate witness monuments. * * * Notation of any self-imposed restrictions, setback lines, and locations of any building lines proposed to be established in this manner. * * * * * Location of burial grounds, railroad rights-of-way, water features (bodies of water, drainage channels, streams, tidal and non-tidal jurisdictional wetlands) courses, existing agricultural or forestal land, conservation easements or open space lands. * * * * * Physical and Topographical Data: Existing topography with a maximum contour interval of two feet except that where existing ground is on a slope of less than two percent, either one-foot contours or spot elevations shall be provided where necessary, but not more than 50 feet apart. Topographic mapping shall identify all significant vegetation, natural features, rock outcroppings, and shall be supplemented with location of all underground structures, utilities and public improvements located on or impacting the development of the property. * * * Soil types as identified in the USDA Soil Conservation Service publication, Soil Survey of the City of Suffolk, or the United Soil Classification System, or by a professional acting within their area of competence, and specifically denoting graphically any areas containing soils rated "Moderate" or "Severe" or which do not have sufficient load bearings for the type of development proposed. The presence or absence of "shrink-swell" and similar soils shall be noted on the face of the plan. * * * The location of all streams as shown on the USGS 7.5 minute topographic maps, as described in the stream buffer standards. * * * * * Location and boundaries of Chesapeake Bay Overlay District areas, including Resource Management Areas, Resource Protection Areas (RPA) and Intensely Developed Areas, including location of 100′ RPA buffer. * * * * * Notation stating: "All land disturbance, uses, development and redevelopment in the Chesapeake Bay Preservation Area Overlay District are required to retain an undisturbed vegetated 100-foot buffer area around RPA features, such as wetlands, shorelines and along waterbodies with perennial flow". * * * * * If an on-site sewage system is proposed within the Chesapeake Bay Preservation Area Overlay District, notation stating: "On- site sewage treatment systems shall be pumped out at least once every five years, subject to the provisions in Section 31- 415(c)(6) of the Unified Development Ordinance". * * * * * Within the Chesapeake Bay Preservation Area Overlay District, notation stating: "For new construction, any on-site sewage treatment system not requiring a Virginia Pollutant Discharge Elimination System permit shall have a 100% reserve sewage disposal area. Building construction of a permanent nature is prohibited within the reserve sewage treatment site". * * * * * Within the Chesapeake Bay Preservation Area Overlay District, notation stating: "Only certain specified activities may be permitted in the RPA, Resource Protection Area, such as approved water dependent facilities, redevelopment, roads and driveways, flood control and bona fide agricultural activities and wetlands restoration activities". * * * * * 100-year Floodplains, including FEMA panel numbers. No. * * * * * Jurisdictional (as defined by U.S. Environmental Protection Agency and U.S. Army Corps of Engineers) wetlands, both tidal and nontidal. * * * * * Existing water features (bodies of water, drainage channels, streams and other watercourses). * * * * * Major utility easements or rights-of-way including above ground electric transmission line easements. * * * * * Natural heritage and historic resource areas * * * * * The location, arrangement and dimensions of all proposed and existing lots. * * * * * The approximate location, dimensions, and area of all parcels of land proposed to be set aside for active and passive open space (in square footage and acres) and/or pedestrian paths. * * * * * Site Layout: The location and arrangement of all proposed uses. * * * Proposed building(s) height, maximum permitted height within applicable zoning district, first floor elevation and area. * * Whenever the proposed development covers only a part of an applicant's contiguous holdings, the applicant shall submit, at the scale of no more than 200 feet to the inch, a sketch of the proposed subdivision or development area, together with its proposed street system and an indication of the probable future street and drainage system of the applicant'(s) contiguous holdings. * * * When the development is to be constructed in phases, a final sequence of development schedule graphically showing the order * * * * * of construction of such phases, and approximate completion date for the construction of each phase. All phase lines shall be clearly depicted on an overall layout sheet and individual layout sheets. Each individual phase meet all requirements of the Unified Development Ordinance. The location of all entrances onto adjacent streets, whether existing or proposed. * * * * Existing significant vegetative cover, including all healthy shrubs or vegetation, including trees to be preserved through a tree retention plan consistent with (section B-23). Existing vegetation used to meet canopy requirements within Section 31-603 must be identified as tree protection (hatching and square footage) on demolition, erosion and sediment control, and landscaping plans. * * * Proposed irrigation system if separate from the domestic water system. * * * Flood Prevention Plan consistent with Section B-15, for development in the floodplain overlay district. * * * A lighting plan consistent with Section B-18 and Section 31-604. * * * The location of signs, including type. * * * * An architectural plan consistent with Section B-11. * * Location of solid waste containers including proposed design provisions for screening, including the location, horizontal and vertical dimensions. * * The proposed treatment of the perimeter of the development, including materials and techniques used (such as screens, fences, walls and other landscaping), and the type and height of screening. * * * Information relating to compliance with the adequate public facilities requirements of Section 31-601 of this Ordinance, consistent with Section B-19. * * * * * Grading plan (including cross-sections and final contours) consistent with Section B-16 and the Erosion and Sedimentation Control Regulations. * * If retaining walls are proposed, a note shall provided stating that the wall is for reference only, is not approved as part of plan, and requires a separate building permit. * * Landscape plan (section B-17) * * All school and service district lines, with the school attendance areas and service district boundaries properly designated. (Reserved) All proposed mechanical equipment shall be depicted and labeled along with required screening. * * Streets and Parking: The street and the pedestrian circulation system, including the location and width of all streets, driveways (excluding driveways for single family residential lots), entrances to parking areas and parking structures, walkways and bicycle paths. * * * * * Off-street parking and loading areas, and fire lanes (excluding driveways for single-family residential lots), including the location, surface type, number of spaces; dimensions (including size and angle) of spaces and bays; width of aisles; handicapped parking spaces, bicycle parking, driveways, sidewalks, pedestrian paths; and landscaping for parking areas. Directional arrows showing flow of traffic, two-way drive aisles, and one- way drive aisles shall be provided. * * * Any drive-through lanes, including arrows showing flow of traffic, aisle widths, and vehicle stacking spaces in compliance with Section 31-606. * * * All street locations and dimensions, their names, numbers, and rights-of-way with profiles and cross-sections of all proposed streets showing proposed cuts and fills. All construction details pertaining to the street improvements (e.g., pavement details, pavement width, curbing, sidewalk, unpaved areas, entrances, lighting, etc.) shall be shown on typical section, in plan and profile, as required by the Director. plans and profiles for all street improvements in public rights-of-way, including centerline elevations computed to the nearest 0.01 foot at 50-foot horizontal station intervals and at other locations of geometric importance. * * Location of proposed street signs. * * * Existing and proposed street curb, gutter and sidewalks along all streets contiguous to the proposed development. * * * Sight distances, both horizontal and vertical, at all proposed entrances. * * * * Sight visibility triangles at all street intersections, entrances to street and parking lot drive aisles, in accordance with Appendix C. * * * * * Entrance grades (in percent) noted. * * * Virginia Department of Transportation Subdivision and Site Plan Inventory Checklist; VDOT Land Development Manual, Volume One. * * * * * Drainage: Stormwater management plan showing plan and profile of proposed storm sewer and drainage facilities, detail sheets, hydrological and hydraulic calculations and other information as required by the Director. * * Plans of contributing drainage areas and the computed limits of the 100-year floodplain, with drainageway cross-sections and water surface elevation plotted on a profile of the pre- and post- development condition, when required by the Director. * * Lot grades to the nearest 0.1′ shall be provided * * Plans and profiles detailing the provisions for the adequate disposition of stormwater, including: • The location, size, type and grade of ditches; • Catch basins; • Pipes (including type or class) and connections to existing drainage systems; • Verification of receiving line or channel adequacy; • Best management practices (BMP) water quality facilities; • On-site storm water retention where deemed appropriate and necessary by the Director of environmental and development services. * * Calculations for both pre- and post-development drainage and storm water management specifying the source of the coefficients and equations utilized and any modifications made thereto. Include Chesapeake Bay Preservation Area calculations for compliance with Chesapeake Bay Preservation Area water quality requirements. * * Floodplain studies when required by the terms of the Floodplain Overlay District. * * * * * Drainage divides and areas for both pre- and post-development conditions. * * * 2-, 10-, and 100-year elevations shown for stormwater management ponds. * * Utilities: Proposals for connection with existing water supply and sanitary sewage systems, or alternative means of providing water supply and sanitary waste treatment and disposal. * * * Plans, profiles and data sheets in accordance with the Water and sewerage facilities standards. * * Plans and profiles for all proposed public utilities, including elevation computed to the nearest 0.01' foot at 50-foot horizontal station intervals and at other locations of geometric importance. Conflicts with existing public utilities shall be shown on plans and profiles as well. * * Location of all sanitary sewer lines and water lines verifying supply and receiving line adequacy, and showing all pipe sizes, type and grades. * * * Location of all existing and proposed fire hydrants; and calculations verifying adequacy of fire flow when required by the Director of Public Utilities. * * Locations of existing and proposed street lights, electric and telecommunications improvements. * * Where private sewage disposal systems are permitted, the affected site plan or subdivision plat shall be provided with the following notations: Where septic tanks are to be installed, there must be an approval on an individual lot basis by the local Health Department at the time an application is made for a septic tank permit. Approval of this site plan or plat by the City does not assure that the individual parcels are suitable for septic systems. * * Additional information: Any other additional information deemed necessary by the Director to demonstrate compliance with any requirement of this Ordinance shall be provided or shown on the plan as appropriate. * * * * * … B-8. PRELIMINARY SUBDIVISION PLATS OR PRELIMINARY SITE PLANS. (a) Three (3) Fifteen (15) clearly legible, blue or black line folded copies printed in black ink shall be submitted to the Director with the appropriate application form and fee. No plan shall be deemed received until all relevant fees and applications are submitted. … B-9. FINAL SUBDIVISION PLATS OR SITE PLANS. … (b) NUMBER OF COPIES. Three (3) Fifteen (15) full size copies of the final plat printed in black ink on black or blue line prints and a reduced size copy of the plat on 8½″ ×11″ or 8½″ × 14″ paper shall be submitted to the Director with the appropriate application form and fee. No plan shall be deemed received until all relevant fees and applications are submitted. … B- 10. SUBDIVISION ENGINEERING PLANS. Three (3) Fifteen (15) copies of the Subdivision Engineering Plans or Site Plans sealed by the appropriate authorized design professional shall be submitted to the Director for review. The Construction Plans shall be at any scale from one inch equals ten feet (1″ = 10′) through one inch equals one hundred (100) feet (1″ = 100′), with the exception that 1″ = 25″ is permitted so long as the scale is an increment of ten feet and is sufficiently clear in reflecting details of the proposed construction. Subdivision Engineering Plans or Site Plans shall be prepared on 24″ × 36″ sheets. The title page shall be used as the cover sheet for the Subdivision Engineering Plans or Site Plans. The Plans shall include, but are not limited to the following information, shown on separate sheets: … STAFF REPORT DESCRIPTION ORDINANCE TEXT AMENDMENT O TA2026-011: Presented for your consideration, attached please find proposed amendments to the Code of the City of Suffolk to amend Sections 31-506(b) and 31-605(h). The purpose of the text amendment is to update and refine the Code of the City of Suffolk, Chapter 31, Unified Development Ordinance due to a change in circumstance. APPLICANT: The proposed ordinance text amendment has been initiated by the City of Suffolk. PUBLIC NOTICE: This request has been duly advertised in accordance with the public notice requirements set forth in Section 15.2- 2204 of the Code of Virginia, as amended, and with the applicable provisions of the Unified Development Ordinance. STAFF ANALYSIS ISSUE AND BACKGROUND At their August 18, 2026 meeting, City Council approved a motion to have the Planning Commission review and recommend amendments to Section 31-506 of the Unified Development Ordinance that include requirements for all lots, including the residue, to have a minimum amount of public road frontage, prohibit flag lots, and provide any other improvements to the minor subdivision standards. Staff has prepared proposed amendments to Section 31-506 CLASSIFICATION OF APPLICATIONS AND GENERAL PROCEDURAL REQUIREMENTS Subs ection 31 - 506(b)(2) GENERAL PROCEDURES MINOR SUDVISIONS and Section 31-605 LOT LAYOUT STANDARDS Subsection 31-605(h)(1) FLAG LOTS. These proposed amendments specify that flag lots are not permitted in minor subdivisions and that all lots created through a minor subdivision, including the residual portion of the parent tract, must meet the required minimum frontage on a fully dedicated public street. RECOMMENDATION In that regard, the proposed text amendment shown in the attached Exhibit B is presented for your favorable consideration with a staff recommendation for approval. Attachments • Proposed Ordinance • Exhibit A – Planning Commission Recommendation • Exhibit B – “Amendments to Sections 31-506(b) and 31-605(h) of the Unified Development Ordinance of the City of Suffolk, Virginia” ORDINANCE NUMBER AN ORDINANCE TO AMEND SECTIONS 31-506(b) AND 31-605(h) OF THE UNIFIED DEVELOPMENT ORDINANCE OF THE CITY OF SUFFOLK, VIRGINIA; OTA2026-011 WHEREAS, the City of Suffolk, Virginia has initiated the aforementioned amendments to the Code of the City of Suffolk, Unified Development Ordinance for the purpose of updating and improving clarity and consistency due to a change in circumstances; and, WHEREAS, the specified amendments to the Unified Development Ordinance as shown in Exhibit “B” are in compliance with the 2045 Comprehensive Plan, as adopted; and, WHEREAS, the Planning Commission has made a recommendation as stated in Exhibit "A"; and, WHEREAS, the procedural requirements for the consideration of this request by the Planning Commission have been met. NOW, THEREFORE, BE IT ORDAINED by the Council of the City of Suffolk, Virginia, that: Section 1. That Exhibit “B,” “Amendments to Section s 31-506(b) and 31-605(h) of the Unified Development Ordinance of the City of Suffolk, Virginia ” which is attached hereto, is hereby incorporated as part of this ordinance. Section 2. That Unified Development Ordinance , Sections 31-506(b) and 31-605(h) are hereby amended to read as referenced in Exhibit “B,” attached. Section 3. All phrases, clauses, sentences, paragraphs, subsections, sections and chapters of the Code not amended hereby remain in full force and effect. This ordinance shall be effective upon passage and shall not be published. READ AND PASSED: TESTE: Erika S. Dawley, City Clerk Approved as to Form: _________________________________ William E. Hutchings, Jr., City Attorney Exhibit “A” RESOLUTION NO. 26-10-03 CITY O F SUFFOLK PLANNING COMMISSION A RESOLUTION TO PRESENT A REPORT AND RECOMMENDATION TO CITY COUNCIL RELATING TO OTA2026-011 AN ORDINANCE TO AMEND SECTIONS 31-506(b) AND 31-605(h) OF THE UNIFIED DEVELOPMENT ORDINANCE OF THE CITY OF SUFFOLK, VIRGINIA. WHE REAS, the City of Suffolk, Virginia has initiated the aforementioned amendments to Chapter 31 of the Unified Development Ordinance for the purpose of updating and improving clarity and consistency due to a change in circumstances; and WHE REAS, the specified amendments to the Unified Development Ordinance as shown in Exhibit “B” are in compliance with the 2045 Comprehensive Plan, as adopted; and WHE REAS, the procedural requirements for the consideration of this request by the Planning Commission have been met. NOW , THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Suffolk, Virginia, that: Sec tion 1. Findings. The Suffolk Planning Commission finds that the proposed ordinance amendments are reasonable and warranted. Sec tion 2. Recommendation to City Council. The Planning Commission recommends to the City Council of the City of Suffolk, Virginia that the proposed amendments be; _____a. A dopted as submitted without modification. _____b. D enied, and that Council not pass the proposed ordinance. _____c. Adopt ed with the modifications set forth on the attached listing of specific recommendations, and that Council adopt the proposed Ordinance with such modifications. READ AND ADOPTED: TESTE: “Exhibit B” “Amendments to Sections 31-506(b) and 31-605(h) of the Unified Development Ordinance of the City of Suffolk, Virginia” SEC. 31-506. CLASSIFICATION OF APPLICATIONS AND GENERAL PROCEDURAL REQUIREMENTS. … (b) GENERAL PROCEDURE. … (2) MINOR SUBDIVISION. The following may be processed as a minor subdivision: A. The division of any land that will result in the creation of not more than four (4) lots, including the parent tract, fronting on an existing street, not involving any new street or road, or the extension of public facilities or the creation of any public improvements, and not adversely affecting the remainder of the parcel or adjoining property, and not in conflict with any provision or portion of the Comprehensive Plan or the Ordinance may be processed as a minor subdivision unless otherwise provided herein. B. New lots created in accordance with subsection A above must be located within the physical boundaries of their associated parent tract as it existed on March 1, 1970. C. Family subdivisions, in accordance with the procedures and standards of Section 31-514 of this Ordinance. D. Final plats of minor subdivisions approved by the Director or his designee prior to April 19, 2023, as evidenced by the signature of the Director or his designee on minor subdivision plats recorded in the land records of the office of the Circuit Court Clerk of the City of Suffolk, shall not be rendered null and void for failure to meet the requirements of subsection A above. E. Flag lots shall not be permitted in minor subdivisions. F. All lots created through a minor subdivision, including the residual portion of the parent tract, must meet the required minimum frontage as specified in TABLE 407-1: DIMENSIONAL STANDARDS of Section 31-407. The required frontage must be on a fully dedicated public street accepted and maintained by the City or the Virginia Department of Transportation. … SEC. 31-605. LOT LAYOUT STANDARDS. … (h) FLAG LOTS. (1) Not more than the following number of flag lots may be authorized to allow for the more efficient use of irregularly shaped parcels of land, or where the integrated nature of multiple buildings on a site dictates the need for such lots. Flag lots may be used to better use irregularly shaped properties or sites with physical limitations. Flag lots shall not be permitted where they will increase the number of lots that take their access from collector or arterial streets. Flag lots shall not be permitted as part of a minor subdivision. MAXIMUM NUMBER OF FLAG LOTS Size of Subdivision or Site Plan Maximum Number or Percentage (%) of Flag Lots 10 or fewer lots 1 lot 11—50 10% 50 + ≤ 5% … RZN2026-002 (Conditional) – PRUDEN LAKE PRINCE STAFF SUMMARY DESCRIPTION REZONING REQUEST: Rezoning Request, RZN2026-002 (Conditional), Pruden Lake Prince, a request to change the zoning from RE, Rural Estate zoning district to RM, Residential Medium Density (Conditional) Zoning District and B-2, General Commercial (Conditional) Zoning District for properties located at 3840 Pruden Boulevard and Lake Prince Drive, Zoning Map 24, Parcels 5 and 6. APPLICANT: John Napolitano, Napolitano Homes, applicant, on behalf of Lake Prince Associates, LC, property owner. LOCATION: The subject property is located at 3840 Pruden Boulevard and along the eastern side of Lake Prince Drive, just north of the intersection of Lake Prince Drive and Pruden Boulevard. PRESENT ZONING: The subject parcels ( T.M. 24*5 and T.M. 24*6) are currently zoned RE, Rural Estate zoning district. The entire property is approximately 79 acres in size, with the southern boundary located within the Special Corridor Overlay District (SCOD) along Pruden Boulevard. EXISTING LAND USE: The majority of the subject property consists of crop fields, with wooded portions along the eastern and southern boundaries. An unimproved access driveway bisects the property. PROPOSED LAND USE: The applicant proposes to rezone 65.7 acres of the property from RE, Rural Estate zoning district to RM, Residential Medium Density (Conditional) zoning district, for the purpose of developing 147 single- family detached homes. The remaining 13.5 acres is proposed to be rezoned to B-2, General Commercial (Conditional) zoning district. SURROUNDING LAND USES: North – Single-family detached homes, fields, and mature wooded areas zoned RE, Rural Estate. South – Two single-family detached homes and Pruden Boulevard, with crop fields and forest to the east of Providence Road beyond, zoned RE, Rural Estate. To the west of Providence Road is Providence United Methodist Church zoned RE, Rural Estate, and the Idlewood single -family r esidential subdivision zoned RLM, Residential Low - Medium Density. East – A single -family dwelling and wooded area zoned RE, Rural Estate, with Excel Equipment and Duke Collision center beyond zoned B-2, General Commercial. West – Lake Prince Drive, with single -family detached homes, crop fields and wooded areas beyond zoned RE, Rural Estate. COMPREHENSIVE PLAN: The City’s 2045 Comprehensive Plan designates this area as a part of the Central Growth Area, Commercial Corridor and Traditional Neighborhood Land Use Types. CHESAPEAKE BAY PRESERVATION AREA DESIGNATION: The property is located within the City’s Chesapeake Bay Preservation Area Overlay District (CBPA) and is designated as a Resource Management Area (RMA). The 100-foot Resource Protection Area (RPA) buffer is also present along a portion of the eastern property boundary of T.M. 24*6. FLOODPLAIN: The property falls within Flood Zone X (areas of minimal risk) as shown on Flood Insurance Rate Map (FIRM) Panel 5101560195E of the City of Suffolk, Virginia Flood Map dated July 7, 2026. CASE HISTORY: A prior version of this application, RZN2024-017, was scheduled for Planning Commission public hearing and was withdrawn by the applicant prior to consideration. The current application, RZN2026-002, represents a similar application and the same rezoning r equest, with some changes from the prior. ISSUE: The applicant proposes to conditionally rezone approximately 79 acres of property located at 3840 Pruden Boulevard and along Lake Point Drive, further identified as Zoning Map 24, Parcels 5 and 6, from RE, Rural Estate zoning district, to RM, Residential Medium Density (Conditional) zoning district and B-2, General Commercial (Conditional) zoning district. As depicted on the attached rezoning exhibit, the applicant proposes to rezone a 65.7- acre portion of the property to RM (Conditional) to develop a residential subdivision that will contain a maximum of 147 single - family detached dwelling units. The remaining 13.5 acres of property located at the corner of Lake Prince Drive and Pruden Boulevard is proposed to be rezoned to B-2 (Conditional). Potential users or specific development within the commercial area has not been identified by the applicant at the time of this report; however, the applicant and property owner have provided a proffer statement in which certain intensive land uses permitted within the B -2 district have been voluntarily prohibited. A wetlands delineation conducted found wetlands to be located on the site and bisecting the northern portion of the parcel. The presence of the observed wetland areas reduces the developable acreage of the property, which impacts the potential number of units that could be constructed on the site. Specifically, the net developable acreage of the portion to be rezoned to residential measures 52 acres, which if rezoned to RM, would yield a maximum of 228 units; however, the applicant has proffered as a part of this request that the total number of units shall be limited to 147 units. The proposed development will be required to meet all applicable development regulations for residential subdivisions and commercial uses. Sources: Esri, TomTom, Garmin, FAO, NOAA, USGS, © OpenStreetMap contributors, and the GIS User Community 0 1 2 3 40.5 Miles ^_ Author: KOSSAI Date: 04-01-2026 ± GENERAL LOCATION MAP RZN2026-00002 Subject Property VILLAGE TRADITIONAL NEIGHBORHOOD SUBURBAN NEIGHBORHOOD RIGHT OF WAY RURAL NEIGHBORHOOD RURAL CONSERVATION RURAL AGRICULTURE PARKS AND OPEN SPACE OFFICE/INSTITUTIONAL MIXED USE CORE MULTIFAMILY NEIGHBORHOOD Employment Center COMMERCIAL CORRIDOR Central Growth Area ^_ SUBJECT PROPERTY 5857 Harbour View Boulevard, Suite 202 Suffolk, Virginia 23435 O. 757.935.9014 F. 757.935.9015 www.landplanningsolutions.com Pruden Boulevard/Lake Prince Drive Rezoning - Narrative Description The applicant is seeking to rezone a +/-79-acre property located at the corner of Pruden Boulevard and Lake Prince Dr ive from the existing RE, Rural Estate district, to a combination of B -2, General Commercial (Conditional), and RM, Residential Medium (Conditional). The subject parcels include Tax Map 24*6 and 24*5, and Account Numbers 251410600 and 250500000. The property is located about two miles northwest of the Route 58 Bypass, ½ mile from the College & Career Academy at Pruden, and one mile from Nansemond- Suffolk Academy. The site is less than a five-minute drive to the new Publix grocery store and a three -minute drive to the Port 460 Logistics Center under construction. The applicant proposes a community that is sensitive to the surrounding l arge-lot s ingle-family homes and the physical characteristics of the property which is heavily forested and comprised of wetlands and steep slopes. As you enter Pruden Boulevard heading northwest from the Route 58 off-ramp, the corridor is comprised of commercial, industrial, and institutional uses primarily on the northern side that lessen in intensity past Kings Fork Road. Under the previous 2035 Comprehensive Plan the western boundary of the City’s Central Growth Area terminated at the intersection of Pruden Boulevard and Kings Fork Road. The southern side of Pruden Boulevard is undergoing significant growth in manufacturing, warehouse, and technology uses as part of the Port 460 Logistics Center. The 2045 Comprehensive Plan strategically extended the Central Growth Area roughly two miles westward along Pruden Boulevard to incorporate the subject property and continue for another 1.5 miles until the intersection of Pruden Boulevard and Gardner Lane. The newly expanded area is suitable for commercial and residential growth that will help balance and complement the existing uses and planned land uses. The 2045 Comprehensive Plan designates the subject parcel as part of the Commercial Corridor land use category at the intersection of Lake Prince Drive and Pruden Boulevard while the remainder of the parcel is designated Traditional Neighborhood. The applicant proposes +/ -13.5 acres of B-2 zoning consistent with the Comprehensive Plan and the Unified Development Ordinance. The locational criteria for B-2 district is met as the property is located at the intersection of an arterial street and a major collector street. The B-2 area will add to the continuity of commercial zoning that is in place along Pruden B oulevard and support walkability between the small commercial area and new residences creating a mixed-use, pedestrian-friendly community. The rem ainder of the site , +/-66 acres, is well suited for a cluster subdivision as it will create a logical transition in land uses from the subject property to the surrounding large-lot single-family homes. While the 2045 Comprehensive Plan calls for a density of 4- 10 dwelling units per acre, we believe this would be too intense at this site given the surrounding large-lot single-family homes and the existing environmental features. When the 2045 Comprehensive Plan was in draft form, the rear of the property was slated for 1 -4 dwelling units per acre in the Suburban Neighborhood land use category. The applicant’s original analysis and preparations were based on this designation. The proposed RM district with a density of roughly 3 units per acre was selected as it’s much more sensible to the adjoining properties and suitable for site’s topography , forested areas and wetlands. To achieve the Comprehensive Plan’s desired density of 4-10 units per acre , the Pruden Boulevard/Lake Prince Drive Rezoning Application March 26, 2026 site would have to be developed with an attached product and many of the forested areas on-site would have to be eliminated. This would be less suitable for many reasons – the impacts on adjacent properties, impacts on traffic, utilities, public schools, and the environment. The conceptual layout for the RM district envisions a total of 147 homes with interior lots that are roughly 6,600 SF in size and larger perimeter lots that are 10,000 square feet as a transition to the adjacent homes. The conceptual layout features an interconnected street network, open spaces, and parks and trails along wooded areas. Perimeter buffers will be provided adjacent to the external roadways, the commercial area, and between existing homes and the new subdivision. This rezoning will also afford the necessary right -of-way dedication for long-term roadway improvements to be made on Pruden Boulevard and Lake Prince Drive. Overall, the proposed rezoning is compatible with the adjacent single -family homes and appropriate for the western portion of the City’s Central Growth Area, as well as this site’s specific environmental characteristics. This project will aid in providing a more even balance of residential uses in relation to the Port 460 Logistics Center and nearby retail growth taking place on Godwin Boulevard. Sincerely, Melissa Venable Land Planning Solutions PROVIDENCE RD. GLENWOOD DR. LABRADOR LN. LAKE PRINCE DR. PRUDEN BLVD./ROUTE 460 Pruden Blvd./Lake Prince Dr. Rezoning Exhibit Suffolk, Virginia September 11, 2026 5857 HARBOUR VIEW BLVD. STE. 202 SUFFOLK VA. 23435-2657 LAND PLANNING SOLUTIONS www.landplanningsolutions.comLAND PLANNING SOLUTIONS O 757.935.9014 F 757.935.9015 N SITE DATA: Account Numbers:251410600 & 250500000 Tax Map Numbers:24*6 & 24*5 Property Owner:Lake Prince Associates L.C. Current Zoning: RE Proposed Zoning:B-2 & RM (Conditional) Commercial B-2 Area: +/- 13.5 a.c. Residential RM Area: +/- 65.7 a.c. Total Site Area:+/- 79.2 a.c Area of Rezoning:+/-79.2 a.c. LEGEND: Area to rezone from RE to RM (Conditional) Area to rezone from RE to B-2 (Conditional) Jurisdictional Wetlands *This conceptual layout was prepared using the survey dated 11-13-2024 by Alphatec. Final engineering may affect unit count. RESULTS OF THE CITY COUNCIL MEETING OF September 16, 2026 A. CONDITIONAL USE PERMIT REQUEST, CUP2026-00011, CEP Solar: to grant a Conditional Use Permit to establish a solar energy facility on property located on Old Myrtle Road, Zoning Map 23, Parcels 2,3,4,5, and 20. B. ORDINANCE TEXT AMENDMENT, OTA2026-05, initiated by the City of Suffolk, for amendments to Section 31-406, Table 406- 1, Section 31- 701, Accessory Uses and Structures, and Appendix A, Definitions, of the Unified Development Ordinance of the City of Suffolk, Virginia. C. ORDINANCE TEXT AMENDMENT, OTA2026-009, initiated by the City of Suffolk, for amendments to repeal Section 31-415, enact Section 31-415.1, and amend Appendix B-13 of the Unified Development Ordinance of the City of Suffolk, Virginia. The purpose of the text amendment is to update and refine the Code of the City of Suffolk, Chapter 31, Unified Development Ordinance. D. COMPREHENSIVE PLAN AMENDMENT, CPA2026 -01, initiated by the City of Suffolk, to revise Chapter 2, “Land Use and Growth Management,” of the 2045 Comprehensive Plan to incorporate policy language and action strategies regarding cumulative acreage caps and limits for utility-scale solar facilities. Denied Denied Approved Approved

Source: City of Suffolk website. First collected Oct 17, 2026.