RecordWell Data

ARC Packet 8 12 26_Optimized

Town of Brookfield · Waukesha County · meeting of Aug 7, 2026 · Agenda packets

Open the original document More from Town of Brookfield

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

PLEASE NOTE: It is possible that members of and possibly a quorum of members of other governmental bodies of the municipality may be in attendance at the above meetings to gather information. No action will be taken by any governmental body other than that specifically noticed.Also, upon reasonable notice, efforts will be made to accommodate the needsof individuals with disabilities through appropriate aids and services. For additional information or to request such services contact the clerk’s office at the above. Page 1 of 1 Town of Brookfield 645 N. Janacek Road Brookfield, WI 53045 (P) 262-796-3788 (F) 262-796-0339 MEETING NOTICE Meeting will be held at the Town of Brookfield Municipal Building, Eric Gnant Room 645 N. Janacek Road, Brookfield, WI Wednesday, August 12, 2026 Architectural Review Committee 6:00 p.m. AGENDA 1. Call to Order. 2. Meeting Notices. 3. Approval of Agenda. 4. Approval of Minutes a. May 13, 2026 Meeting Minutes b. June 10, 2026 Meeting Minutes 5. Old Business: None. 6. New Business: a. Review and possible action on a request for an electronic changeable copy sign for St. John’s Lutheran Church located at 20275 Davidson Road. Brian Zach on behalf of St. Johns (owner), Lemberg Electric (applicant). b. Review and possible action on a request for walls signs for Landro Real Estate located at 601/611 N. Barker Road. Princess Properties 601 LLC (owner), Karen Dodge (applicant). c. Review and possible action on a request for a wall sign for CD One Price Cleaners, located at 19035 W. Bluemound Road. Brooktown Plaza, LLC (owner), First Ad Signs (applicant) d. Review and possible action on a request for a Site Plan/Plan of Operation to construct a dog park at Brookfield Highlands Apartments, located at 20880 George Hunt Circle. Brookfield Highlands Apartm ents Limited Partnership I (owner) Alex Siehoff (applicant) e. Preliminary and Final Approval for Johnson Financial Group to construct a financial institution at 17740 W. Bluemound Road. Bluemound Enterprises Limited Partnership (owner), Eric Ohlfs (applicant) f. Preliminary and Final Approval for Restoration Hardware located in The West End, 20351 W. Bluemound Road. Newfield Holdings, LLC, Robert Gould (applicant); IM Property Investments (USA) LLC (owner). 7. Communications and Announcements. a. Update on Master Sign Plan for Galleria West b. Next meeting date: September 9, 2026 8. Adjourn. Posted this 6th day of August, 2026 Rebekah Leto Town Planner TOWN OF BROOKFIELD ARCHITECTURAL REVIEW COMMITTEE MINUTES MAY 13, 2026 Page 1 of 4 The regular meeting of the Architectural Review Committee was held in the East Conference Room of the Town Hall, 645 N Janacek Road, Brookfield, WI. 1) CALL TO ORDER Chairman Dean Pearson called the meeting to orderat 6:00 p.m. with the following people present:Town Supervisors John Charlier, Steve Kohlmann, Matt Paris; Committee members Richard Diercksmeier, Alan Lee; and Town Planner Rebekah Leto. 2) MEETING NOTICES Planner Leto reported that the meeting was noticed in accordance with Open Meeting Law. 3) APPROVAL OF AGENDA Motion by Mr. Kohlmann to approve the agenda as presented. Seconded by Mr. Charlier. Motion carried unanimously. 4) APPROVAL OF MINUTES Motion by Mr. Charlier to approve the minutes of the April 8, 2026 minutes as presented. Seconded by Mr. Kohlmann. Motion carried unanimously. 5) OLD BUSINESS None. 6) NEW BUSINESS a. Review and possible action on a request to replace two development entry signs for Foxhaven, located east of Springdale Road and south and west of Watertown Road. Fast Signs (applicant), Wimmer Communities (owner). Planner Leto gave an overview of the proposal in accordance with the staff re port, noting that the proposed location may be in conformance with the proposed zoning but it was unclear. The Town Highway Superintendent approved the location of the new signs. Planner Leto also discussed the changes from the existing and proposed sign,most notably that “of Brookfield” was being removed and a website was being added. Chairman Pearson noted that he would like to see “Town of Brookfield” on the sign. The applicant noted it changes the type of the frame they are proposing. Mr. Charlier noted that he does not mind the website being added to the sign, but agrees that Town of Brookfield should remain. Mr. Kohlmann concurred, stating that he would be okay with the additional information on the sign so long as Town of Brookfield was on the sign. The applicant clarified where the town name should be and the Committee said underneath the name. Architectural Review Committee Minutes May 13, 2026 Page 2 of 4 Motion by Mr. Charlier to approve a request to replace two development entry signs for FoxHaven, located at Springdale and Watertown Roads, with the addition of Town of Brookfield being added to the sign, which may slightly extend the sign size, subject to the Planner’s approval. Seconded by Mr. Kohlmann. Further Discussion: None. Motion carried unanimously. b. Review and possible action on a request for a wall-mounted sign for the American Society of Gene and Cell Therapy (tenant) at 20700 Swenson Drive. Sign Effectz (JTM LLC (owner). Planner Leto gave an overview of the proposal in accordance with the staff report, noting that a sign waiver was required. Mr. Kohlmann asked if this was a new sign and Planner Leto said yes, but same design. The applicant clarified that it was not a new sign, but that they were taking down the sign from one building and putting it up on the other building. Planner Leto noted that her report has incorrect information in it, as she used the existing sign information from the original permit. Motion by Mr. Kohlmann to approve a wall-mounted sign for the American Society of Gene and Cell Therapy,including any required waivers, located at 20700 Swenson Drive as presented. Seconded by Mr. Lee. Further Discussion: None. Motion carried unanimously. c. Review and possible action on a request for signage at 325 N. Brookfield Road for Studio 6 Extended Stay. Bauer Sign & Lighting (applicant). BRE/HV Properties, LLC (owner). Planner Leto gave an overview of the proposal in accordance with the staff repo rt. Mr. Charlier observed that the existing signs had already been removed. Motion by Charlier to approve signage for Studio 6 Extended Stay, located at 325 N. Brookfield Road as presented. Seconded by Lee. Further Discussion: None. Motion carried unanimously. d. Review and possible action on a request to install wall signage and a tenant panel at Soap and Suds (tenant) located at 18000 W. Bluemound Road. Bauer Signs & Lighting (applicant). Harvard Square Baceline LLC (owner). Planner Leto gave an overview of the proposal in accordance with the staff report. Planner Leto showed a sign of the temporary sign that was installed, noting the banner sign area was the same size as the proposed sign, which was significantly larger than the Code allowed. Chairman Pearson asked if there was a Master Sign Plan for Harvard Square and Planner Leto was not sure, but if so, it was likely outdated at this point. The Committee generally agreed there likely was not one. The Committee discussed how the proposed sign area looks proportional with the signs that are installed on the building. Mr. Charlier noted that if the sign met the Code, it might look too small and Mr. Lee agreed. Planner Leto noted how that was a lot of discrepancy between the tenant panel sizes amongst the permit applicants over the years and even the building frontage of this tenant space. The applicant agreed to submit the final tenant panel once they can get up to measure it. Architectural Review Committee Minutes May 13, 2026 Page 3 of 4 Motion by Charlier to approve wall signage and a tenant panel at Soap and Suds, located at 18000 W. Bluemound Road as presented. Seconded by Lee Further Discussion: None. Motion carried unanimously. e. Review and possible action on a request for Final approval for a mixed -use development known as The West End, located west of The Corners of Brookfield, Tax Key Nos. BKFT1123.960 -.965; BKFT1123.976.001, .004, .005. IM Properties (applicant), Newfield Holdings LLC and Brookfield Corners LLC (owners). Planner Leto gave an overview of the proposal in accordance with the staff report. The architect gave some additional updates to the project, including that they were no longer proposing EV surface stalls, but would be placing some within the parking garage structure and would meet all Fire Department requirements. Planner Leto also noted a correction to the staff report that there were no rooftop mechanicals being proposed. Mr. Kohlmann asked if the ARC gets to review traffic circulation, which Planner Leto noted yes. He recommended an additional stop sign at the N. Lord St. and S. Union St. intersection. Planner Leto noted that one was added in the location being suggested since the Preliminary submittal. Chairman Pearson commented that the Plan Commission would generally look at the landscaping being proposed. Motion by Mr. Kohlmann to recommend Final approval for a mixed-use development known as The West End, located west of The Corners of Brookfield as presented, with the following conditions: 1. Prior to the issuance of a Building Permit, documentation that the Wisconsin Department of Transportation has reviewed and approved a Traffic Impact Analysis. Financial assurance in a form acceptable to the Town Attorney shall be submitted to ensure any required improvements are constructed as required by the DOT or Waukesha County. 2. The parking study should be updated to include, at a minimum, additional information relative to the existing use of the underground parking garage and the source of the 1.2 spaces /unit residential ratio versus the required 2 spaces/unit residential ratio. 3. Prior to the issuance of a Building Permit, all comments of the Town Planner, Town Engineer, Sanitary District, Fire Department and Town Attorney, if applicant, shall be complied with and shown on the final plans. 4. A Certified Survey Map shall be submitted, reviewed and approved by the Town of Brookfield and any extra-territorial review entity, prior to permits being issued. Note: a CSM has been submitted and will be on the June Plan Commission agenda. 5. Prior to the issuance of a Building permit, a revised Landscaping Plan shall be submitted that includes add additional native species as recommended by the Town Engineer that is sufficient to the Town Engineer and Planner. Financial assurance may be collected in a form acceptable to the Town Attorney to ensure all required landscaping is implemented and maintained for a period of time approved by the Town Board. 6. The Landscaping plan, inclusive of the landscaping in the parking lot, perimeter, and green roof, shall be revised to include the amount of green space and landscaping areas being proposed to ensure compliance with Section 17.02(6)(a)(19). Architectural Review Committee Minutes May 13, 2026 Page 4 of 4 7. Documentation shall be provided by the applicant that the Town Fire Department has reviewed and approved the plans for the proposed Electronic Vehicle surface stalls relative to the requirements of Ordinance 2026-01. 8. Renderings of the development signage shall be submitted for consideration of the ARC, Plan Commission and Town Board. Seconded by Mr. Charlier. Further Discussion: None. Motion carried unanimously. f. Discussion and recommendation to Town Board on proposed modifications to Section 17.08 (Signage). Planner Leto gave an overview of the proposed changes to the Code. The committee agreed that such a sign should not face a residential area and noted that these types of signs still need to meet the current code requirements for electronic message boards. Motion by Charlier to recommend to Town Board approval of proposed modifications to Section 17.08 (Signage) as presented. Seconded by Mr. Lee. Further Discussion: none. Motion carried unanimously. 7) COMMUNICATION AND ANNOUNCEMENTS: a. Next meeting date: June 10, 2026 8) ADJOURN Motion by Mr. Kohlmann to adjourn at 6:53 pm. Seconded by Mr. Charlier. Motion carried unanimously. Respectfully submitted, Rebekah Leto, Town Planner TOWN OF BROOKFIELD ARCHITECTURAL REVIEW COMMITTEE MINUTES JUNE 10, 2026 Page 1 of 3 The regular meeting of the Architectural Review Committee was held in the East Conference Room of the Town Hall, 645 N Janacek Road, Brookfield, WI. 1) CALL TO ORDER Chairman Dean Pearson called the meeting to orderat 6:05 p.m. with the following people present:Town Supervisors John Charlier, Steve Kohlmann and Committee member Alan Lee; and Town Planner Rebekah Leto. 2) MEETING NOTICES Planner Leto reported that the meeting was noticed in accordance with Open Meeting Law. 3) APPROVAL OF AGENDA Motion by Mr. Charlier to approve the agenda as presented. Seconded by Mr. Kohlmann. Motion carried unanimously. 4) APPROVAL OF MINUTES No action taken. The April Minutes were included in the packet instead of the May minutes. 5) OLD BUSINESS None. 6) NEW BUSINESS a. Review and possible action on a request to install wall signage for Prescient Financial Solutions (tenant) at 20300 Water Tower Blvd. Signs and Lines by Stretch (applicant), Three Gear Holdings LLC (owner). Planner Leto gave an overview of the proposal in accordance with the staff report, pointing out the history of the signs on the building. Leto also pointed out that the Nort hwestern Mutual font was only 7.5 sq. ft. and may not be legible, given the scale of the building. The building owner and tenant, Jerry David, spoke, noting that they are a branch of Northwestern Mutual, who requires that their name be a part of the sign b ut does not care how big it is. He explained how he wanted his business to be the largest part of the sign (Prescient). Mr. Kohlmann questioned the sign maximum regulations, observing that waivers for sign size seem to be more and more prevalent. Chairman Pearson gave some history of how the sign size regulations came to be, and Planner Leto explained how sign area was measured. Motion by Mr. Lee to approve a request to install wall signage for Prescient Financial Solutions at 20300 Water Tower Blvd., as presented. Seconded by Mr. Charlier. Further Discussion: None. Motion carried unanimously. Architectural Review Committee Minutes June 10, 2026 Page 2 of 3 b. Review and possible action on a request for two wall signs for Board Game Barrister (tenant) at 18900 W.Bluemound Road. Lemberg Electric (applicant), LMR II Galleria West LLC (owner). Planner Leto gave an overview of the proposal in accordance with the staff repo rt, nothing that this unit has double frontage, with the entrance door being on the east side and the south elevation had full length windows, with an awning. The Committee discussed how the entrance is confusing here and people may not know where to go, not ing that an “entrance” sign may be appropriate. They also discussed how two signs is not in line with the Code and may not be appropriate. Because the frontage is small, one sign seems appropriate, noting that the customer could determine which elevation they wanted to place the sign. The Committee discussed at length the Master Sign Plan for Galleria West and directed Planner Leto to reach out to the owners about updating the MSP. Motion by Mr. Kohlmann to approve one wall-mounted sign, at the size presented and with the option for the tenants to mount the sign on either the east or south elevation, for Board Game Barrister (tenant) at 18900 W. Bluemound Road as presented. Seconded by Mr. Charlier. Further Discussion: None. Motion carried unanimously. c. Review and possible action on a request for Preliminary and Final approval for building and site alterations proposed for Pabla Plaza/Taste of India restaurant and banquet hall, located at 18110 W. Bluemound Road. Roger Schregardus (applicant), Manjit Singh (owner). Planner Leto gave an overview of the proposal, noting that there have been many changes since the staff report was sent due to a response from the Town Engineer. The lighting plan needs to be revised to meet Town Code. The landscaping and the dumpster enclosure are within a storm sewer easement and may not be doable. The Committee noted that additional green space is necessary and discussed the addition of planters around the building. The owner replied that was doable. It was noted that signage would be completed at a later date. Motion by Mr. Charlier to recommend Preliminary and Final approval for building and site alterations proposed for Pabla Plaza, including the Taste of India restaurant and banquet hall, located at 18110 W. Bluemound Road, subject to staff approval of an updated photometric plan to meet Town Code and subject to landscaping planters placed around the building to add greenery. Seconded by Mr. Lee. Further Discussion: None. Motion carried 3-1, with Chairman Pearson opposing. d. Review and possible action on a requestfor a new wall sign and tenant panel for Anahata Yoga (tenant) at 275 Regency Court Suite 101. Grave Signs (applicant), Pete and Louie Liapis (owners). Planner Leto gave an overview of the proposal in accordance with the staff report. Motion by Mr. Charlier to approve a new wall sign and tenant panel for Anahata Yoga located at 275 Regency Court Suite 101 as presented. Seconded by Mr. Kohlmann. Further Discussion: None. Architectural Review Committee Minutes June 10, 2026 Page 3 of 3 Motion carried unanimously. e. Review and possible action on a request for two wall signs at Kerns Carpet (tenant) at 21795 Doral Road. Innovative Signs (applicant), KH Holdings Doral LLC (owner). Planner Leto gave an overview of the proposal in a ccordance with the staff report, noting the proposed signs comply with the Master Sign Plan for the development. The Committee commented that the building looks really nice. Motion by Mr. Kohlmann to approve two wall signs at Kerns Carpet located at 21795 Doral Road as presented. Seconded by Mr. Lee. Further Discussion: None. Motion carried unanimously. f. Review and possible action on a request for campus signage, including directional signage and wall signs, three flagpoles, and an architectural globe feature for the KHS Campus, located at 880 Bahcall Court. Innovative Signs (applicant), KHS Inc. (owner). Planner Leto gave an overview of the p roposal in accordance with the staff report. The applicant brought lighting cut sheets and a landscaping plan to the meeting. The owners noted that they would be willing to turn the globe feature light off at night. The Committee discussed how to light 20-25’ tall flag poles. The owners noted only the American flag would be lit. The landscaping plan included the Vision Corner Triangle and all features are located outside of it and meet the setbacks. The Committee noted how nice the addition and site plan look. Motion by Mr. Charlier to approve the campus signage, including the directional and wall signs, flag height and architectural globe feature, including the lighting and landscaping presented at the meeting, for KHS located at 880 Bahcall Court, as presented. Seconded by Mr. Kohlmann. Further Discussion: None. Motion carried unanimously. 7) COMMUNICATION AND ANNOUNCEMENTS: a. Next meeting date: July 8, 2026 8) ADJOURN Motion by Mr. Kohlmann to adjourn at 7:28 pm. Seconded by Mr. Charlier. Motion carried unanimously. Respectfully submitted, Rebekah Leto, Town Planner PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD ARCHITECT URAL REVIEW COMMITTEE STAFF REPORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 RE: Proposed freestanding electronic changeable copy sign at 20275 Davidson Road, BKFT 1135.012.001 APPLICANT: Lemberg Electric OWNER: St. John’s Lutheran Church, Brian Zach The following report is provided for cursory review prior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. St. John’s Lutheran Church is located on the southeast corner of Davidson Road and S. Barker Road. The parcel is approximately 4.9 acres. Existing improvements include the church, parking lot and a monument sign located in the northwest corner of the property. The petitioners are proposing to remove the existing sign and construct a new electronic changeable copy sign on S. Barker Road. An electronic changeable copy sign requires a Conditional Use Permit. On June 26, 2026, the Plan Commission recommended approval of the Conditional Use for an electronic changeable copy sign, subject to the conditions listed below. On July 16, 2026, the Town Board approved the sign as recommended by the Plan Commission. The sign itself still requires Architectural Review Committee approval. The proposed and required electronic changeable copy sign setbacks and dimensions are as follows: Proposed Required Sign Area 49 sq. ft. total area EMC – 24.3 SF, less than 50% of the sign area Maximum 70 Sq. ft., with the ECC less than 50% of the total sign face North setback (Davidson Rd) 180 ft. +/- 50 ft. or as otherwise approved by the PC West setback (S. Barker Rd) 5 ft. 5 ft. min. as approved by the Plan Commission St. John’s ECC Sign- ARC PLANNING & ZONING LLC 2 The proposed sign hardware has the built-in ability to meet the Town’s illumination limits. According to the plans, the sign includes a built-in light sensor and programming software that lets the installer cap how bright the LEDs can get. Because the sign can technically be turned up brighter if left unprogrammed, staff recommends making it a condition of approval that the applicant lock the software settings. Specifically, the sign must be programmed to never exceed 100 footcandles during the day (6:00 a.m. to 7:00 p.m.) and 45 footcandles at night (7:00 p.m. to 6:00 a.m.) when measured one foot away from the sign face. The background of the sign is “Penny Wise” (copper) with white illuminated letters. The height of the sign, including a 2’ base, is 9’-2” tall, which complies with the freestanding height requirements based on the height of the building (37’). Address numerals are not present on the plan set submitted; however, the applicant has also provided alternative renderings for the ARC to consider in their discussion. The applicant is concerned that the address numerals may be confusing given that the numerals align with Davidson Road addresses and the sign will be located along Barker Road. The existing sign does not have numerals. It should be noted that the changeable copy section of the Code does not require address numerals similar to the freestanding sign section. However, ARC should discuss the options, including precedent, and may require that address numerals be included on the sign, if desired. Recommendation: Staff recommends conditional approval of the sign, subject to the following conditions: 1. A Conditional Use Order shall be prepared by town staff, signed by the property owner, and recorded by the Town in the Waukesha County Register of Deeds, prior to a sign permit being issued. The Conditional Use Order shall outline the conditions of an Electronic Changeable Copy Sign and the illumination standards as noted in the Code, in addition to the standard conditional use conditions used by the town regarding noncompliance, revocability and nuisance complaints. 2. The Waukesha County Board shall approve the text amendment approved by the Town of Brookfield, prior to a sign permit being issued. The Waukesha County Board approved the text amendments on July 28, 2026. 3. The proposed sign shall be a minimum of 5 ft. from the established road right of way of S. Barker Road, which is 30 ft. from the edge of the curb. A revised site plan shall be submitted to Staff showing the final location of the sign, prior to permits being issued. 4. Potential condition: Address numerals shall be added to the base of the sign, as required by the ARC. PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD ARCHITECT URAL REVIEW COMMITTEE STAFF REPORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 RE: Wall signs for Landro Real Estate, located at 601 N. Barker Road The following report is provided for cursory review prior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. Landro Real Estate is a new tenant in the multi-tenant office building at 601 N. Barker Road, on the east side of the building with frontage on Barker Road. The applicant is requesting two walls signs, one for the east elevation and one for the north elevation that faces Watertown Road. The sign locations are the same as the previous tenant. The proposed signs consist of dimensional cream-colored letters that are mounted flush to the building wall and are non-illuminated. The proposed sign information is as follows: Proposed Max. Permitted Waiver required? East Elevation 11 ft. x 1 ft. 7 in. (17.3 SF) 112 SF per 140 linear ft. of frontage No North Elevation 11 ft. x 1 ft. 7 in. (17.3 SF) 54 SF per 68 linear ft. of frontage No # of signs 2 Max. 2 for office buildings No The proposed sign meets the Ordinance requirements and no waivers are required. Recommendation: I recommend approval of the wall signs for Landro Real Estate located at 601 N. Barker Road, as presented. Concept C · Front S1: S2 - Dimensional Letters Mockup Design Details SIGN TYPE Dimensional Letters ILLUMINATION Per final engineering MOUNTING Flush COLORS & FINISHES Logo 1 Color 1: FT-Black-03-C · CMYK 0/12/25/97 Logo 1 Color 2: FT-Gray-04-C · CMYK 0/1/1/48 Logo 1 Color 3: FT-Gray-01-C · CMYK 2/2/0/17 DIMENSIONS W 11 ft · H 1 ft 10 in MATERIALS Acrylic Milwaukee Sign Company Page 4 of 5 Milwaukee Sign Company · 262.372.4030 · kelly@milwaukeesigncompany.net Page 4 of 5 Concept C · Front Continued Additional renderings and specification visuals Measurement Diagram Cross-Section Milwaukee Sign Company Page 5 of 5 Milwaukee Sign Company · 262.372.4030 · kelly@milwaukeesigncompany.net Page 5 of 5 Concept B · Front S1: S2 - Dimensional Letters Mockup Design Details SIGN TYPE Dimensional Letters ILLUMINATION Per final engineering MOUNTING Flush COLORS & FINISHES Logo 1 Color 1: FT-Black-03-C · CMYK 0/12/25/97 Logo 1 Color 2: FT-Gray-04-C · CMYK 0/1/1/48 Logo 1 Color 3: FT-Gray-01-C · CMYK 2/2/0/17 DIMENSIONS W 11 ft · H 1 ft 10 in MATERIALS Acrylic Milwaukee Sign Company Page 2 of 5 Milwaukee Sign Company · 262.372.4030 · kelly@milwaukeesigncompany.net Page 2 of 5 Concept B · Front Continued Additional renderings and specification visuals Measurement Diagram Cross-Section Milwaukee Sign Company Page 3 of 5 Milwaukee Sign Company · 262.372.4030 · kelly@milwaukeesigncompany.net Page 3 of 5 PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD ARCHITECT URAL REVIEW COMMITTEE STAFF REPORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 RE: Wall sign for CD One Price Cleaners, located at 19035 W. Bluemound Road, Unit 4 The following report is provided for cursory review prior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. CD One Price Cleaners is a new tenant in a multi-tenant building (Brooktown Plaza) with frontage on W. Bluemound Road. The applicant is proposing a single wall sign. The sign consists of illuminated channel set letters on a mounted raceway. The letters will be cyan and white with a cyan outline, and a gray color for the hanger of the logo. When illuminated, the letters will be white with “CD” and the logo outlined in cyan. The proposed overall sign information is as follows: Proposed Max. Permitted Waiver required? 12.13’ x 2.5’ (31.34 SF) 19.2 SF per 24’ linear ft. of frontage Yes The proposed sign name with the logo exceeds the maximum sign size permitted for the unit frontage. The sign name on its own would equate to approximately 23.9 sq. ft. and the logo is approximately 6.6 sq. ft. The sign does not comply with the sign size requirements and a waiver is required. Recommendation: At the discretion of the ARC. PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD STAFF REPORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 RE: Site Plan/Plan of Operation (Conceptual, Preliminary, Final approval) for a Dog Park at Brookfield Highlands Apartments, located at 20880 George Hunt Circle, BKFT 1129.999.028 The following report is provided for cursory review prior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. Property owner: Brookfield Highlands Apartments Limited Partnership I, c/o Alex Siehoff Applicant/Operator: Same Proposed Use: Dog Park for 55+ apartment community Zoning: RM-1, Residential Multifamily District Project Description and Use Brookfield Highlands Apartments is a 55+ community with 519 apartments within 14 two-story buildings. There is an existing area on the northwest side of the development that is utilized as a dog exercise area that the applicant is looking to make into a more formal dog park for the residents. The current area is not fenced in and leashes are required. Nearby is a walking path, decorative bollard lighting, benches and multiple dog waste stations. Improvements include a fenced area for off-leash dogs in an area that is approximately 3,350 sq. ft. (78 ft. x 43 ft.). There will be a double-gated entry vestibule that provides access to separate areas for small and large dogs. The fence will be a 4 ft. high decorative black aluminum fencing. The space will have artificial turf and dog agility equipment, training platforms, benches and dog waste receptacles. The hours of operation are proposed from 8:00 am to 9:00 pm. Enclosed are a site plan, play structure plan, and examples of the fencing and signage at another facility managed by the applicant. Additional details are as follows:  A dog park rules sign will be installed at the entrance gate.  Waste receptacles are emptied weekly. Seven additional waste stations are located throughout the property. Brookfield Highlands Dog Park SPPO PLANNING & ZONING LLC 2  The community has a 50 pound pet weight limit. Approximately 40 dogs currently reside in the community. Seven of the 14 apartment buildings are pet friendly. Lease agreements require all dogs to be licensed and current on vaccinations.  No change to the existing grades are proposed.  No additional lighting is proposed.  One declining maple tree will be removed and a stone mulch strip installed along the fence line.  No water service or drinking fountains are proposed. Adjacent to the north of the property is Crossroads Corporate Center Business Park. The proposed location is between two of the residential multi-family buildings and the facilities building is directly north. Further east and west are single family residential neighborhoods (approximately 360 ft. to the east). Residents are, and will continue to be, responsible for controlling excessive barking. Town staff had no comments or concerns regarding the application. Staff Recommendation Staff recommends approval of the Site Plan/Plan of Operation for Brookfield Highlands Dog Park located near 880 George Hunt Circle, as presented. The area is already being utilized as a leashed dog area. The proposed improvements will formalize it and allow dogs to be exercised with agility equipment, which may be important for a 55+ community where mobility may be more limited for some residents. The dogs are must be registered, licensed and up to date with their vaccinations with a 50 lb. weight limit. While residents come and go, there are currently only 40 dogs of the 519 apartment units (7%). This is a small percentage of residents who have dogs and it is unlikely all dogs will be outside at the same time. The hours of operation will also help to limit any noise generated during early morning or late night time hours. Enclosures S:\Development Services\Applications\Plan of Operation (PC Review)\2026\Brookfield Highlands Dog Park\Brookfield Highlands Dog Park Staff Report.docx 660 West Ridgeview Drive | Appleton, WI 54911 Phone: 920-968-8100 | Fax: 920-731-1696 July 22, 2026 Rebekah Leto, AICP Town Planner, Town of Brookfield Planning & Zoning LLC 262-796-3760 planning@townofbrookfieldwi.gov RE: Letter of Intent – Brookfield Highlands Dog Park 20880 George Hunt Circle Waukesha, WI 53186 Dear Rebekah Leto: Enclosed is the application package for the proposed dog park improvements at Brookfield Highlands Apartments 55+, submitted for review by the Plan Commission, Architectural Review Board, and Town Board. This submittal includes the Application for Review, applicable filing fee, and supporting documents. Enclosed are the following: • Dog Park Enhancements Drawings o Property Overview and Existing Conditions o Site Plan • Proposed Dog Play Equipment • Existing Site Photos and Google Street View • Photos of Similar Dog Park Installed at Another Arden Property Group Development o Fence, Turf, Play Equipment, and Signage Site Information: Brookfield Highlands Apartments 55+ is an existing independent senior living community consisting of 519 apartment units located within 14 two-story residential buildings with one level of underground parking. The development was constructed in phases between 1989 and 1996 and is accessed from George Hunt Circle via Davidson Road. The existing designated dog park is located within a landscaped green space between Buildings 4 and 5 and the maintenance building. The area currently consists of natural turf buffered by mature deciduous and evergreen trees. Adjacent amenities include a paved walking path, decorative bollard lighting, benches, and multiple dog waste stations. 660 West Ridgeview Drive | Appleton, WI 54911 Phone: 920-968-8100 | Fax: 920-731-1696 Project Summary : The proposed project will enhance the existing dog park by converting a portion of the current open, leashed exercise area into a secure, fenced, off-leash dog park for residents. The improvement is intended to enhance an existing resident amenity by providing a safe, enclosed area where residents can comfortably exercise their dogs off-leash while encouraging responsible pet ownership and minimizing impacts to other areas of the property. As a private amenity for Brookfield Highlands Apartments 55+, the dog park will support the quality of life for residents by providing a dedicated, well-designed space for pet recreation within the existing community. The proposed enclosure will remain within its existing location and will measure approximately 78 feet by 43 feet (approximately 3,350 square feet). The design includes a double-gated entry vestibule providing access to separate areas for small and large dogs. The enclosure will consist of 4-foot-high decorative black aluminum fencing with matching gates. The interior surface will be artificial turf designed specifically for pet use and will include dog agility equipment, training platforms, benches, and dog waste receptacles. Responses to Planning and Engineering Initial Questions: • Signage – o A dog park rules sign will be installed at the entrance gate. A sample is included with this submittal. • Use of the Facility o The dog park will be a private amenity available exclusively to Brookfield Highlands residents. • Waste Management o Dog waste receptacles will be provided within the park and emptied weekly by on-site maintenance staff. Seven additional waste stations are located throughout the community. • Large and Small Dogs o Separate areas are provided for both large and small dogs. Brookfield Highlands maintains a 50-pound pet weight limit, excluding approved emotional support and service animals. • Number of Dogs o Approximately 40 registered dogs currently reside within the community. Seven of the fourteen apartment buildings are designated as pet friendly. • Hours of Operation o 8:00 a.m. to 9:00 p.m. • Fencing o 4-foot-high decorative black aluminum fencing. Reference photos are included. 660 West Ridgeview Drive | Appleton, WI 54911 Phone: 920-968-8100 | Fax: 920-731-1696 • Vaccinations and Licensing o Resident lease agreements require all dogs to be licensed and current on required vaccinations. • Grading and Erosion Control o Existing grades will remain unchanged. The pervious artificial turf and fencing will follow the existing 1.5% slope. The disturbance area is below Wisconsin DNR NOI permitting thresholds. Any required Town permits will be obtained. • Lighting o No additional lighting is proposed. Existing decorative bollard lighting will remain. • Landscaping o A stone mulch strip will be installed along the fence line. One declining maple tree will be removed while all remaining trees will be preserved. • Buffers and Noise o The improvements enhance an area already used for dog exercise. Existing mature trees, drive aisles, and parking areas provide buffering. Residents are responsible for controlling excessive barking. • Water Service o No water service or drinking fountains are proposed. Water for maintenance will be supplied from the existing hose bib at the maintenance building. Company History: Arden Property Group Inc (formerly known as United Financial Group) is a family-owned organization with more than 40 years of experience owning and operating apartment communities, and currently has a portfolio of more than 3,500 units (primarily age-restricted 55+ developments) within the state of Wisconsin. In addition, UFG has 35+ years of experience building, owning, and operating the Brookfield Highlands senior community in the Town of Brookfield. Thank you for taking the time to review and consider our proposal. Sincerely, Alex Siehoff Director of Facilities Brookfield Highlands 20900 George Hunt Cir Waukesha, WI Agility Bone Training Platform Trail Bench Pet Waste Station Pet Waste Station Bridge Climb - 29” Tunnel House Leash Post & Toy Box 79 ft 1 Panel = 8’ W x 5’ H 1 Entrance Gate = 4’ W x 5’ H Posts = 2.5” W, In-Ground Mount This Park Materials with Hardware: 3 DVR (steel) Entrance Gates 41 DVR Panels 48 DVR Posts • Turf ships in 15’ wide rolls • Cut long allowing room for tucking • Seam tape (12 ft W x 20’ L per roll) and green seam adhesive (1 gal for 40 linear ft) included in quote This Park Materials: 3 turf rolls @ 79 ft Seam Tape: 8 rolls Adhesive: 6 gallons = Turf Roll Trail Bench Trail Bench Training Platform BRIDGE CLIMB- 29” DL-BC2-RPW-10019 • Observation hill • Jumping platform • Socialization station • Shaded comfort • Tunnel run thru • Socialization station • Relaxation • Shaded comfort • Tunnel run thru • Companionship & socialization • Relaxation • Obedience & training • Companion seating TUNNEL HOUSE DL-TH2-RPW TRAINING PLATFORM DL-TP1-RPW AGILITY BONE DL-EBPB2-FBR THE DOG POST - LEASH POST & TOY BOX DL-LP-RPW • Allows guests to stay hands free • Great for leashes, water, & toys! PAW WASTE STATION DL-PWS100-FS-TPC BRIDGE CLIMB - 24“ TALL DL-BC2-RPW-10020 • Observation hill • Jumping platform • Socialization station • Shaded comfort • Tunnel run thru • Companion seating • Relaxation • Jump Training SURFACE MOUNT TRAIL BENCH DL-TB-4-SM-RPW +(905.44) NORTH1" = 30'030'60' Brookfield Highlands ApartmentsBROOKFIELD, WISCONSIN07/16/2026PROPOSED DOG PARK ENHANCEMENTS PROPOSDED DOG PARKENHANCEMENT AREA EXISTINGBENCHES EXISTING MAPLETO BE REMOVED(DECLINING HEALTH)EXISTINGTURF EXISTING DECIDUOUSTREES, TYP. EXISTINGPARKING GEORGE HUNT CIRCLE EXISTINGLEASHED DOGPARK/ GREENSPACE STRIPED WALKINGPATH, TYP.EXISTING CONIFERTREES, TYP. EXISTINGBOLLARD LAMPEXISTING DOGWASTE STATION,TYP. EXISTINGPARKING FACILITIESBUILDING GEORGE HUNT CIRCLEEXISTING LEASHED DOG PARK/GREEN SPACE OVERALL SITE (NTS) DAVIDSON ROAD BLDG 4 BLDG 5 BLDG 3BLDG 2BLDG 6BLDG 9 BLDG 12 BLDG 14BLDG 8 BLDG 7 BLDG 10BLDG 11 BLDG 13BLDG 1 PROPERTY OVERVIEW AND EXISTING CONDITIONS NORTH1" = 30'030'60' Brookfield Highlands ApartmentsBROOKFIELD, WISCONSIN07/16/2026PROPOSED DOG PARK ENHANCEMENTS EXISTING ASPHALT WALKEXISTING BENCHESMETAL FENCE W/ STONEMAINTNENANCE EDGESYNTHETIC TURF EXISTING TURF EXISTING DECIDUOUSTREES, TYP. BUILDING 5(20900) BUILDING 4(20880) FACILITIESBUILDING EXISTINGPARKINGEXISTINGPARKING EXISTING TURF GEORGE HUNT CIRCLE 77'-6" DOGPARK CONCRETE WALK/ENTRY GATES42'-6" STRIPED WALKINGPATH, TYP. EXISTING CONIFERTREES, TYP. EXISTING BOLLARD LAMP DOG PARK AMENITIESAND BENCHES, TYP.EXISTING DOGWASTE STATION, TYP. TRAINING AREA SITE PLAN Photos of Dog Park at Highlands at Aero Park Same Signage, Fence, Gates, Turf, and Play Equipment to be used at Brookfield Highlands Typical Signage Typical Gate Entry and Fence Typical Stone Mulch Maintenance Strip Along Fence Typical Artificial Turf, Benches, and Dog Equipment PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD STAFF REPORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 (ARC) REPORT DATE: August 6, 2026 RE: Preliminary and Final Approval for the construction of a financial institution with a service drive-thru lane, Johnson Financial Group, 17740 W. Bluemound Rd, BKFT1120.996 The following report is provided for cursory review p rior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. Property owner: Bluemound Enterprises Limited Partnership Applicant: Eric Ohlfs, The Redmond Company, on behalf of Johnson Financial Group Application Type: Preliminary and Final Approval Zoning: B-2 Limited General Business District Project Description The property is 2 acres and is located on the north side of W. Bluemound Road. The property was formerly Don and Roy ’s Motorsports and contains a cell tower in the northwest corner of the site . The petitioner is proposing to raze all existing structures, except the cell tower, and construct a one-story financial institution with drive-thru lanes for Johnson Financial Group. The surrounding area consists of condominiums to the north, a multi-tenant commercial building to the west and a Metro Market grocery store (in the City of Brookfield) to the east. The petitioners are seeking Preliminary and Final Approval of the development. Architectural Plans: The proposed one-story building is 8,669 sq. ft. The building is more modern, with a flat roof and metal canopy. Materials include modular brick veneer, blended stone veneer, aluminum composite metal panels, faux wood aluminum siding, cast stone si ll. The combined materials give the building an overall look of brick and wood, with a Lannon stone base and metal accents. Site Plan: The proposed building is located approximately 100 ft. from the edge of the road right of way of W. Bluemound Road. The site will be graded flat, with new storm sewer installed that will outlet to a 300 sq. ft. bio -filter (rain garden), which is a stormwater facility, located on the north portion of the site Johnson Financial Group – Prelim/Final Phase PLANNING & ZONING LLC 2 within the green space. The current site consists of 75% impervious surface, whereas the proposed site will be only 60.69% impervious surface. A concrete sidewalk is proposed from W. Bluemound Road to a curb bump out at the front of the building, including a crosswalk. A less than 2 ft. tall retaining wall is proposed along the east lot line. Zoning Proposed Required Requirement met? Road Setback (S) W. Bluemound Rd. 100+/- ft. 50 ft. min. Yes Offset (N) (residential) 231+/- ft. 15 ft. min. Yes Offset (E) 27 +/- ft. 15 ft. min. Yes Offset (W) 59 +/- ft. 15 ft. min. Yes Height 23’-5” 45 ft. max. Yes Maximum Floor Area 8,670 sq. ft. (10.1%) 6,000 sq. ft. (min.) 42,600.5 sq. ft. (50% max) Yes Ingress and Egress : Access to the site is proposed in the existing location off of Bluemound Road. Egress to the site is a right-turn only onto Bluemound Rd. A connection to the Metro Market property was explored, but ultimately is not feasible. Internal traffic patterns: Visitors will enter via Bluemound Road and proceed directly to the parking area or go east around the building to the drive-thru lane or the employee parking. There is a by -pass lane around the drive-thru lanes. A “Do Not Enter” sign is on the west side of the customer parking area to prevent customers from going the wrong way into the drive-thru. Lighting: Ten (10) downcast light poles are proposed throughout the parking and drive aisle areas with 4000K color temperature. Building lighting includes two LED lights over the north door entrances, two LED lights on the east elevation and six LED lights along the building façade facing Bluemound Road. All but two of these lights are wedge wall sconces. The remaining two are flat LED square wafers. The driveway canopy also has down cast lights. The applicant has stated that due to security, they would prefer all lights stay on overnight. The photometric plan complies with the Town lighting standards, per the Town Engineer. Off-street parking and parking landscaping: The area for customer service is approximately 2,300 sq. ft., which would result in 16 required customer parking spaces (1 space/150 sq. ft. of space reserved for customer service). There will be a maximum of 29 employees between the office and branch sides of the building. Therefore, the required parking is 45 stalls. The proposed number of stalls is 53. Two handicap stalls are required per the Town Code and three are proposed. The proposed parking complies with the Code requirements. A 10 ft. paving offset is being provided along W. Bluemound Road and along the east and west lot lines, except for the drive aisles around the building and drive-thru. However, the four-foot curb setback is being met in these locations. It should also be noted that in these areas, much of the lot is currently paved up to the lot line and the condition will be improving. Johnson Financial Group – Prelim/Final Phase PLANNING & ZONING LLC 3 Parking is required to be a minimum of 25 ft. from a residential district, of which 80 ft. is being provided. A 10 ft. l andscape buffer is also required on the north lot line given the additional residential use. The code requires landscaping to screen the use from view year -round. The landscaping plan shows an approximately 80 ft. long vegetative buffer to the north of a p roposed rain garden (bio-filter). The buffer will consist of six (6) Green Giant Arborvitae and four (4) Eastern White Pines. There is a significant woodland feature, approximately 120’ deep and mostly on the condominium property, that screens this property from view. Additional landscaping in the parking area includes the use of landscape islands and peninsulas located at the ends of aisles. The northernmost two landscaping islands each contain one (1) Honey locust tree and lawn, while the remaining islands contain a mix of vegetation. The islands meet the 170 sq. ft. minimum, except for the island that shares space with the sidewalk that connects to the pedestrian crosswalk. Even without this island, the site well exceeds the 5% minimum landscaping requirement for the site. Additional Site Landscaping: There is landscaping proposed along the perimeter of the building and most of the property. There is also a small landscaping berm south of the customer parking near W. Bluemound Road with additiona l landscaping. Landscaping around the proposed monument sign is proposed to contain Millennium Allium and Ice Dance Sedge, which is a perennials and ornamental grass, respectively. The Town Engineer has made some recommendations to add six additional trees in lawn areas and to shield the cell tower more. Additional recommendations include swapping some species for native species and relocating some of the plants further from the building. Signage An exterior sign package has been submitted as part of the development approval. Signage includes the following. Sign Zoning Proposed Area Permitted Area Wavier required Monument along Bluemound Rd. Aluminum base with tan cabinet and black lettering + logo. Illuminated letters. Includes address numerals Complies with height and setback 41.45 SF (excluding base, per code) (total size 10’ H x 8’-8” W) 70 SF No* Address numerals needs to increase to 8”, currently 4” Wall sign (south elevation/Bluemound) Backlit black letters, n/a 29.6 SF (12’-3” x 2’-5”) 90.4 SF No Wall sign (east elevation) Backlit black letters n/a 81.98 SF (38’-5 x 2’-2”) 72 SF Yes, sign size Directional signage (2) ATM/Drive - Up freestanding signs n/a 4’ H x 3’ W With 4” letter height. Max. 5” letter height No. Johnson Financial Group – Prelim/Final Phase PLANNING & ZONING LLC 4 There are multiple places where window signage is proposed, including the hours of operation and address on the entrance door (south elevation); drive up hours on the drive-thru window, and “associate entrance” on the north doors. The site signage includes “do not enter” and parking signage. Dumpsters: The dumpster enclosure is a masonry enclosure with a modular brick veneer and composite decking slat s for the enclosure opening. The enclosure is located in the northwest corner. The use requires two small 4-yard dumpsters on wheels, stored at 90 degrees. The trash company will need to pull them out to lift them up. Therefore, bollards are not proposed and do not seem necessary. Staff Recommendation I recommend Preliminary and Final approval of the request to construct a financial institution located at 17740 W. Bluemound Road, subject to the following conditions: 1. Revised sign plans must be submitted that meet the sign code, unless waivers are approved by the ARC for letter height and sign size on the east elevation. 2. A revised landscaping plan that incorporates the additional recommendations prepared by the Town Engineer shall be submitted for Plan Commission review. The submitted plans require very minor adjustments that can be reviewed internally. The redevelopment of this parcel removes a blighted property from a highly visible location and provides a location for a long- standing business of the area. As submitted, the proposal meets the purpose and intent of the ordinance. S:\Development Services\Applications\Project Plan Review (Conceptual, Prelim, Final) \2025\Johnsons Financial (17740 W Bluemound Rd)\Preliminary Final\Prelim Final Johnson Bank Staff report.docx c The Redmond Company 2026 25010 7/21/2026 Johnson Financial Group - Brookfield Exterior Rendering NOTE: COLORS SHOWN ARE APPROXIMATE. REFER TO ACTUAL PRODUCT SAMPLES FOR ACCURATE COLORS. RENDERINGS ARE SCHEMATIC IN NATURE AND DO NOT INDICATE FINAL GRADING AND LANDSCAPING. VIEW FROM SOUTHWEST VIEW FROM NORTHEAST VIEW FROM NORTHWEST VIEW FROM SOUTHEAST WH 89° 29' 00" 200.00' S E 0° 00' 11" 428.74' N E 0° 00' 11" 442.50' S W 85° 33' 00" 200.61' N WEXISTING SIDEWALK EXISTING SIDEWALK EXISTING RETAINING WALL 4' - 0" 4' PAVEMENT SETBACK 15' BUILDING SETBACK 20' UTILITY EASEMENT 15' - 0" 20' - 0" 50' - 0" 50' BUILDING SETBACK 4' PAVEMENT SETBACK 15' BUILDING SETBACK 4' - 0" 15' - 0" 15' BUILDING SETBACK 15' - 0" 10' BUFFER YARD EXISTING CELL TOWER & FENCE 0° 31' 03" 35.00' S W 89° 28' 57" 55.00' N W 0° 31' 03" 35.00' N E 89° 28' 57" 55.00' S E 20' UTILITY EASEMENT 10' - 0" 2' - 0" 8' - 0" EXISTING TRANSFORMER EXISTING TRANSFORMER 9' - 6" 5' - 0" 9' - 6" 5' - 0" 24' - 0" BY-PASS LANE ATM DRIVE-THRU CANOPY ABOVE 6 10 8 9 9 11 18' - 0" 24' - 0" 18' - 0" (16) CUSTOMER PARKING STALLS TOTAL (37) EMPLOYEE PARKING STALLS TOTAL DRIVEWAY TO CELL TOWER EMPLOYEE ENTRANCE MAIN ENTRANCE (1) BIKE RACK EMPLOYEE ENTRANCE MASONRY TRASH ENCLOSURE 10' TALL MONUMENT SIGN (PROVIDE ELEC.) SIDEWALK SIDEWALK SIDEWALK LANDSCAPED BUFFER YARD RESIDENTIALLY ZONED LOT W. BLUEMOUND RD. 24' - 0" 30' - 0" 14' - 0" AREA LEASED TO CELL PROVIDER ~1,925 SF DEMOLISH EXISTING BUILDINGS CELL TOWER ACCESS EASEMENT FUTURE ATM (1) BIKE RACK RAMP RAMP RAMP RAMP RETAINING WALL DO NOT ENTER SIGN (BY OWNER) DIRECTIONAL SIGN (BY OWNER) DIRECTIONAL SIGN (BY OWNER) DO NOT ENTER SIGN (BY OWNER) ADA VAN SIGN (BY OWNER) ADA VAN SIGN (BY OWNER) ADA SIGN (BY OWNER) DO NOT ENTER SIGN (BY OWNER) 31' - 6 3/16" +/- 1:5 SLOPE 18' - 0" 24' - 0" 18' - 0" 18' - 0" 24' - 0" 18' - 0" 9' - 0" ONE STORY BANK/OFFICE 8,669 SF 1. ADDRESS: 17740 W BLUEMOUND RD, BROOKFIELD, WI 530 45 2. MUNICIPALITY: TOWN OF BROOKFIELD 3. LOT ZONING: B-2 LIMITED GENERAL BUSINESS DISTRICT 4. LOT SIZE: 87,121 SF (2.000 AC) (INCLUDES CELL TO WER LEASE AREA) 5. PERMITTED USE: BANKING INCLUDING DRIVE-IN FACILITI ES 6. CONDITIONAL USE: DRIVE-IN BANKS 7. LOT AREA: 20,000 SF MIN. 8. LOT WIDTH: 120' MIN. 9. BUILDING HEIGHT: 45' MAX. 10. ACCESSORY BUILDING: 15' MAX. 11. BUILDING AREA: 6,000 SF MIN. 12. BUILDING AREA: SHALL NOT EXCEED 50% OF LOT AREA (~43,560 SF MAX) 13. BUILDING SETBACKS A. 50' FROM R.O.W. B. 15' FROM SIDE AND REAR LOT LINE 14. BUFFER YARD - 10' WIDE AT RESIDENTIAL LOT LINE W/ OPAQUE LANDSCAPING 15. PARKING LOT A. PAVEMENT SETBACK: 10' MIN. 16. LIGHTING A. 0.2 FC MAX AT PROPERTY LINE B. 0.4 FC MIN AT PARKING LOT AND CIRCULATION AREAS C. NO LIGHT FIXTURES IN BUFFER YARDS D. LIGHTING <12V EXCLUDED FROM ABOVE RESTRICTIONS 17. LANDSCAPING A. REFER TO ZONING ORDINANCE FOR ADDITIONAL INFO B. NO LANDSCAPING IN UTILITY OR DRAINAGE EASEMENTS (E XCEPT GRASS) C. NO PART OF TREE SHALL EXTEND BEYOND THE PROPERTY LINE 18. TRAFFIC/PARKING A. DRIVEWAY VISION TRIANGLE: 15'X15' BETWEEN 30" TO 10' ABOVE GRADE B. PARKING STALL SIZE: 9'X18' MIN. C. ADA PARKING STALLS SIZE: 12'X18' MIN. D. NO PARKING WITHIN 25' OF A RESIDENTIAL LOT LINE E. PARKING LOT ISLANDS: REQUIRED WHEN >30 STALLS. M INIMUM SIZE OF 170 SF F. PARKING LOT CURB SETBACK: 4' MIN. G. PARKING QUANTITY: 1 STALL PER 150 GSF OF CUSTOME R SERVICE, PLUS 1 PER EMPLOYEE FOR LARGEST SHIFT a. 8,700 SF BUILDING (2,400 CUSTOMER AREA) WOULD RE QUIRE (16) CUSTOMER STALLS & (29) EMPLOYEE STALLS H. DRIVE-THRU QUEUING: (4) VEHICLES PER LANE I. DRIVEWAYS - SEE CHAPTER 8 19. SIGNAGE A. MONUMENT SIGNS a. NOT TO EXCEED A HEIGHT WHEN DRAWING A LINE 10' AT THE PROPERTY LINE TO THE BUILDING HEIGHT b. SIGN TO INCLUDE A 2' TALL MIN. MASONRY BASE WITH L ANDSCAPING BED SHALL BE INCLUDED c. SIGN SETBACK: 5' MIN. d. SIGN AREA: 70 SF OF SIGN DISPLAY AREA PER SIDE e. SIGN QUANTITY: 1 MAX. f. SIGN TO INCLUDE 8"ADDRESS NUMERALS B. BUILDING SIGNS a. SIGN AREA: NOT TO EXCEED 0.8 SF PER LINEAR FOOT OF BUILDING FRONTAGE AT R.O.W. AND 100 SF MAX. EA. b. SIGN QUANTITY: 2 MAX. TOTAL ZONING INFO c The Redmond Company 2026 25010 7/21/2026 Johnson Financial Group - Brookfield Architectural Site Plan N 0' 16' 32' 64' SCALE: 3/64" = 1' -0" 3/64" = 1'-0" PRESENTATION SITE PLAN A1 WH 126 SF VESTIBULE 853 SF LOBBY 253 SF CASH BAR 221 SF TELLER WORK ROOM 34 SF EQUIP. 58 SF FLEX OFFICE 131 SF OFFICE 208 SF CONFERENCE 123 SF OFFICE 124 SF OFFICE 124 SF OFFICE 368 SF BREAK ROOM 243 SF STORAGE 61 SF MOTHERS ROOM 62 SF IT 169 SF CORRIDOR 61 SF WOMENS 61 SF MENS 161 SF MECHANICAL 105 SF CORRIDOR 139 SF OFFICE 70 SF JANITOR 88 SF STORAGE 120 SF OFFICE 80 SF COPY ROOM 119 SF OFFICE 120 SF OFFICE 1663 SF OPEN OFFICE 227 SF CONFERENCE 49 SF ENTRY 304 SF CONFERENCE ROOM 62 SF FOCUS 120 SF OFFICE 120 SF OFFICE 119 SF OFFICE 120 SF OFFICE 122 SF OFFICE 1 2 3 7.1 F D.3 A.9 4 B E C 2.5 SHRED BIN TV TV TV A F.1 D 1.9 12'-0 1/8" 4'-0" 6'-0" 4'-8" 6'-0" 4'-0" 6'-4" 6'-0" 4'-8" 6'-0" 4'-8" 6'-0" 4'-8" 6'-0" 3'-4" 6'-0" 6'-0" 6'-0" 34'-0" 7'-8" 14'-4" 57'-4" 3'-4" 3'-4" 7'-8" 16'-0" 6'-0" 5'-4" 6'-0" 4'-8" 3'-4" 16'-0 " 5'-8" 6'-0" 4'-8" 6'-0" 5'-4" 6'-0" 4'-8" 6'-0" 5'-4" 6'-0" 4 '-8" 6'-0" 5'-4" 20'-8" 2'-5 3/4" 9'-2" 4 7/8" 7'-0" SHRED BIN 5'-0" 8'-2 3/4" 11'-11 1/8" 10'-0 1/8" 10'-0 1/8" 6'-7 1/2" 62 SF WOMENS 62 SF MENS TOTAL BUILDING FOOTPRINT 8,669 SF 120 SF OFFICE 2'-0" 5'-3" 5'-0" 9'-6" 5'-0" 9'-6" 1'-0" 4'-0" 90'-4" 71'-8" ATM FUTURE ATM TELLER TUBE DEAL DRAWER NIGHT DEPOSIT 5'-4" 6'-0" 7'-4" 3'-0" 1'-4" 3'-0" 1'-4" 3'-0" 3'-8" 15'-10" 10'-1 3/8" 30 SF STORAGE CHAIR STORAGE CART 64 SF STORAGE 4'-9 5/8" 10'-3 1/8" COIN SHELF 7'-0 1/4" TELLER SIGHT LINE COMFORT ZONE 13'-3 1/8" 10'-0 1/8" 10'-0 1/8" (2) MICROWAVES COOKIE MAKER COFFEE MAKER DW REF REF 4'-11 11/16" 16'-0 1/16" 5'-0" 7'-0" 16'-0 1/16" 6'-7 1/16" 10'-5 31/32" 5'-0" 10'-5 31/32" 5'-5 21/32" (12) WORKSTATIONS (10) OFFICES 7" 75.0 12'-5 1/8" (8) LOCKERS 66'-0" 34'-0" 7'-8" COAT RACK 62 SF FOCUS 7'-6" 40" 62 SF LOCKERS 6'-3 1/8" 5'-0" 48" RACK 48" RACK 2'-0" TV SPRINKLER RISER ELEC. PANELS ROOF ACCESS 40" 123 SF OFFICE ADA HEIGHT ADJUSTABLE TELLER STATION 10'-0 1/8" 12'-0 7/16" 2'-0" 4'-0" 1'-8" WORK BENCH PALLET AREA 24"Dx48"L RACKING BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE BO SHADE SHELF RACK SECURITY VISTA ALARM D.9 A.8 9" 1'-0" 13'-1" 1'-5" 9'-3" 4'-11" 20'-1" 12'-9" 2'-8" 1'-6" 21'-2" 1'-9" 27'-6" 11" 10" 16'-4" 14'-2" 11'-2" 2'-0" 12'-4" 13'-0" 5'-6 " 6'-4" 27'-0" 2'-0" 1'-9" 4.2 A.1 6.0 D.2 6.4 6.2 1'-4 3/4" 1'-1" 10" 6.7 6.8 c The Redmond Company 2026 25010 7/21/2026 Johnson Financial Group - Brookfield First Floor Presentation Plan 3/16" = 1'-0" FIRST FLOOR PRESENTATION 1 N 0' 4' 8' 16' SCALE: 3/16" = 1' -0" FIRST FLOOR 100' - 0" LOW PARAPET 116' - 0" HIGH ROOF 123' - 5" LOW ROOF 114' - 0" BLENDED STONE VENEER CAST STONE SILL MODULAR BRICK VENEER BLACK ANODIZED ALUMINUM STOREFRONT W/ 1" CLEAR LOW-E GLAZING PREFABRICATED METAL CANOPY MODULAR BRICK VENEER AT DRIVE THROUGH COLUMNS FAUX WOOD ALUMINUM SIDING BUILT-UP CORNICE WITH BREAK METAL AND ROOF EDGE BACK LIT SIGNAGE ALUMINUM COMPOSITE METAL PANELS HIGH PARAPET 120' - 0" PAINTED STEEL COLUMN FIRST FLOOR 100' - 0" LOW PARAPET 116' - 0" HIGH ROOF 123' - 5" LOW ROOF 114' - 0" BLENDED STONE VENEER CAST STONE SILL MODULAR BRICK VENEER BLACK ANODIZED ALUMINUM STOREFRONT W/ 1" CLEAR LOW -E GLAZING PREFABRICATED METAL CANOPY MODULAR BRICK VENEER AT DRIVE THROUGH COLUMNS FAUX WOOD ALUMINUM SIDING BUILT -UP CORNICE WITH BREAK METAL AND ROOF EDGE FAUX WOOD ALUMINUM SIDING FIRST FLOOR 100' - 0" LOW PARAPET 116' - 0" HIGH ROOF 123' - 5" LOW ROOF 114' - 0" BLENDED STONE VENEER CAST STONE SILL MODULAR BRICK VENEER ALUMINUM COMPOSITE METAL PANELS FAUX WOOD ALUMINUM SIDING CLERESTORY AND ROOF OVERHANG BEYOND HIGH PARAPET 120' - 0" BLACK LIT SIGNAGE FIRST FLOOR 100' - 0" LOW PARAPET 116' - 0" HIGH ROOF 123' - 5" BLENDED STONE VENEER CAST STONE SILL MODULAR BRICK VENEER BLACK ANODIZED ALUMINUM STOREFRONT W/ 1" CLEAR LOW -E GLAZING MODULAR BRICK VENEER AT DRIVE THROUGH COLUMNS FAUX WOOD ALUMINUM SIDING BUILT -UP CORNICE WITH BREAK METAL AND ROOF EDGE ALUMINUM COMPOSITE METAL BAND FAUX WOOD ALUMINUM SIDING HIGH PARAPET 120' - 0" PAINTED STEEL COLUMN ALUCOBOND ACM BRUSHED ALUMINUM LONGBOARD ALUMINUM SIDING 6" V-GROOVE, BLONDE OAK GLEN GERY BRICK URBAN GREY HALQUIST STONE FOND DU LAC LEDGE EXTERIOR MATERIAL LEGEND NOTE: COLORS SHOWN ARE APPROXIMATE. REFER TO ACTUAL PRODUCT SAMPLES FOR ACCURATE COLORS. CAST STONE CAP MODULAR BRICK VENEER 6'-0" CAST STONE CAP MODULAR BRICK VENEER CMU AT INTERIOR 6'-0" 6'-0" CAST STONE CAP MODULAR BRICK VENEER COMPOSITE DECKING SLATS 6'-0" CAST STONE CAP MODULAR BRICK VENEER c The Redmond Company 2026 25010 7/21/2026 Johnson Financial Group - Brookfield Exterior Elevations 1/8" = 1'-0" SOUTH ELEVATION - PRESENTATION 1 1/8" = 1'-0" WEST ELEVATION - PRESENTATION 41/8" = 1'-0" EAST ELEVATION - PRESENTATION 3 1/8" = 1'-0" NORTH ELEVATION - PRESENTATION 2 1/8" = 1'-0" TRASH ENCLOSURE - EAST ELEV. 7 1/8" = 1'-0" TRASH ENCLOSURE - NORTH ELEV. 81/8" = 1'-0" TRASH ENCLOSURE - SOUTH ELEV. 61/8" = 1'-0" TRASH ENCLOSURE - WEST ELEV. 5 7/21/2026 C1.01 122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com SUBMITTALJFG - BROOKFIELD17740 W BLUEMOUND ROADBROOKFIELD, WI, 53045 \RE-24-26\ EXISTINGCONDITIONS& DEMOLITIONPLANJDRJDRJDR 7/21/2026 C1.02 122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com SUBMITTALJFG - BROOKFIELD17740 W BLUEMOUND ROADBROOKFIELD, WI, 53045 \RE-24-26\ PROPOSEDSITE PLANJDRJDRJDR W. BLUEMOUND RD. 9 KARL FOERSTER GRASS5 NORTHWIND SWITCHGRASS7 BOBO HYDRANGEA8 GREEN VELVET BOXWOOD 9 GREEN VELVET BOXWOOD26 PRAIRIE DROPSEED3 BOBO HYDRANGEA 8 PRAIRIE DROPSEED3 BOBO HYDRANGEA 7 GRO-LOW SUMAC 5 BOBO HYDRANGEA 14 MILLENIUM ALLIUM9 GRO-LOW SUMAC12 PRAIRIE DROPSEED 1 NORTHWIND SWITCHGRASS3 BOBO HYDRANGEA 3 GRO-LOW SUMAC4 BOBO HYDRANGEA4 BOBO HYDRANGEA8 VISION IN WHITE ASTILBE 6 BOBO HYDRANGEA7 MILLENIUM ALLIUM9 GREEN VELVET BOXWOOD7 MILLENIUM ALLIUM LAWN6 MILLENIUM ALLIUM4 BOBO HYDRANGEA 7 MILLENIUM ALLIUM7 MILLENIUM ALLIUM7 MILLENIUM ALLIUM 3 JAPANESE TREE LILAC 1 SKYLINE HONEYLOCUSTLAWN1 SKYLINE HONEYLOCUST 1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS 9 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS 7 GRO-LOW SUMAC7 GRO-LOW SUMAC 7 GRO-LOW SUMAC7 GRO-LOW SUMAC 1 SKYLINE HONEYLOCUST1 ARMSTRONG RED MAPLE 20 MILLENIUM ALLIUMMONUMENT SIGN52 ICE DANCE SEDGE9 NORTHWIND SWITCHGRASS6 GREEN VELVET BOXWOOD 1 EASTERN WHITE PINE1 BALD CYPRESS5 WICHITA BLUE JUNIPERLAWNLAWN LAWN LAWNLAWNLAWNLAWN LAWN LAWNLAWN LAWN 2" PVC2" PVC 2" PVC 2" PVC2" PVC2" PVC 2" PVC 2" PVC 4" PVC 4" PVC 4" PVC 2" PVC4" PVC 2" PVC 81' 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC LAWN 9 VISIONS IN WHITE ASTILBEJET BLACK STONE OVERFLOW10 VISION IN WHITE ASTILBE7 VISION IN WHITE ASTILBE 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 31' 1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC 13 GRO-LOW SUMAC 3 EASTERN WHITE PINE3 GREEN GIANT ARBORVITAE3 GREEN GIANT ARBORVITAE 2" PVC8 SUGARTINA CRYSTALINA SUMMERSWEET NATIVE PLUGS AT BASIN BOTTOMNATIVE SWALE SEED MIX LAWN LAWN LAWNLAWN LAWN LAWN 9 NORTHWIND SWITCHGRASS MULCH 12" JET BLACK STONE BANDAT BASE OF WALL SHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.0OVERALLLANDSCAPECONCEPT OVERALL LANDSCAPE CONCEPTNORTHScale: 1" = 20'0" HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com RAINWATER RENEWAL NATIVE PLUGS W. BLUEMOUND RD.(U.S.H. "18") 9 GREEN VELVET BOXWOOD26 PRAIRIE DROPSEED3 BOBO HYDRANGEA 8 PRAIRIE DROPSEED3 BOBO HYDRANGEA 7 GRO-LOW SUMAC 5 BOBO HYDRANGEA 14 MILLENIUM ALLIUM9 GRO-LOW SUMAC12 PRAIRIE DROPSEED 1 NORTHWIND SWITCHGRASS3 BOBO HYDRANGEA6 BOBO HYDRANGEA7 MILLENIUM ALLIUM9 GREEN VELVET BOXWOOD7 MILLENIUM ALLIUM LAWN6 MILLENIUM ALLIUM4 BOBO HYDRANGEA 7 MILLENIUM ALLIUM7 MILLENIUM ALLIUM7 MILLENIUM ALLIUM 9 NORTHWIND SWITCHGRASS 9 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS 7 GRO-LOW SUMAC 7 GRO-LOW SUMAC7 GRO-LOW SUMAC 1 SKYLINE HONEYLOCUST1 ARMSTRONG RED MAPLE 20 MILLENIUM ALLIUMMONUMENT SIGN52 ICE DANCE SEDGE9 NORTHWIND SWITCHGRASS6 GREEN VELVET BOXWOODLAWN LAWN LAWNLAWN 2" PVC2" PVC 2" PVC 4" PVC 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS13 GRO-LOW SUMAC 2" PVC8 SUGARTINA CRYSTALINA SUMMERSWEETLAWN 9 NORTHWIND SWITCHGRASS 12" JET BLACK STONE BANDAT BASE OF WALL SHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.1ENLARGEDLANDSCAPECONCEPT:SOUTHENLARGED LANDSCAPE CONCEPTNORTHScale: 1" = 10'0" HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com 9 KARL FOERSTER GRASS5 NORTHWIND SWITCHGRASS7 BOBO HYDRANGEA8 GREEN VELVET BOXWOOD3 GRO-LOW SUMAC4 BOBO HYDRANGEA4 BOBO HYDRANGEA8 VISION IN WHITE ASTILBE3 JAPANESE TREE LILAC 1 SKYLINE HONEYLOCUSTLAWN1 SKYLINE HONEYLOCUST 1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC 1 EASTERN WHITE PINE1 BALD CYPRESS5 WICHITA BLUE JUNIPERLAWNLAWN LAWNLAWNLAWNLAWN2" PVC2" PVC2" PVC 2" PVC 2" PVC 4" PVC 4" PVC 2" PVC4" PVC 2" PVC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC LAWN 9 VISIONS IN WHITE ASTILBEJET BLACK STONE OVERFLOW10 VISION IN WHITE ASTILBE7 VISION IN WHITE ASTILBE 9 KARL FOERSTER GRASS 9 KARL FOERSTER GRASS 1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC NATIVE PLUGS AT BASIN BOTTOMNATIVE SWALE SEED MIXLAWN LAWNLAWN LAWN 9 NORTHWIND SWITCHGRASS MULCH SHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.2ENLARGEDLANDSCAPECONCEPT:CENTERENLARGED LANDSCAPE CONCEPTNORTHScale: 1" = 10'0" HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com 1 SKYLINE HONEYLOCUSTLAWN1 SKYLINE HONEYLOCUST 1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC 1 EASTERN WHITE PINE1 BALD CYPRESS5 WICHITA BLUE JUNIPERLAWNLAWN LAWN 2" PVC 4" PVC 2" PVC4" PVC 2" PVC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC 12 NORTHWIND SWITCHGRASS9 NORTHWIND SWITCHGRASS7 GRO-LOW SUMAC7 GRO-LOW SUMAC LAWN 9 KARL FOERSTER GRASS1 ARMSTRONG RED MAPLE5 NORTHWIND SWITCHGRASS12 GRO-LOW SUMAC 3 EASTERN WHITE PINE3 GREEN GIANT ARBORVITAE3 GREEN GIANT ARBORVITAE NATIVE PLUGS AT BASIN BOTTOMNATIVE SWALE SEED MIX LAWN LAWN LAWN LAWN MULCHSHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.3ENLARGEDLANDSCAPECONCEPT:NORTHENLARGED LANDSCAPE CONCEPTNORTHScale: 1" = 10'0" HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com W. BLUEMOUND RD.(U.S.H. "18") 2" PVC2" PVC 2" PVC 2" PVC2" PVC2" PVC 2" PVC 2" PVC 4" PVC 4" PVC 4" PVC 2" PVC4" PVC 2" PVC2" PVC IRRIGATION ACCESS SLEEVE 2" PVC IRRIGATION ACCESS SLEEVE 2" PVC IRRIGATION ACCESS SLEEVE2" PVC IRRIGATION ACCESS SLEEVE 2"' PVC IRRIGATION ACCESS SLEEVE4" PVC IRRIGATION ACCESS SLEEVE2" PVC IRRIGATION ACCESS SLEEVE 4" PVC IRRIGATION ACCESS SLEEVE 81'31' 2" PVC 2" PVC IRRIGATION ACCESS SLEEVE 4" PVC IRRIGATION ACCESS SLEEVE SHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.4IRRIGATIONSCOPEPLAN IRRIGATION SCOPE PLANNORTHScale: 1" = 20'0" HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com IRRIGATION SCOPE SHADE TREE PLANTING1N.T.S.SECTION EVERGREEN TREE PLANTINGSECTIONN.T.S. DECIDUOUS SHRUB PLANTING (B&B)N.T.S.SECTIONGROUNDCOVER / PERENNIAL PLANTING DECIDUOUS SHRUB PLANTING (POTTED)N.T.S.SECTIONDETAILEVERGREEN SHRUB PLANTINGN.T.S.SECTIONBALLED & BURLAPPEDPOTTEDFIBER POTCONTAINER PLANT SHRUB AT SAMELEVEL AS PREVIOUSGROWING CONDITION ATROOT FLARE.CAREFULLYREMOVE PLANTFROM PLASTIC POT& SCORE ROOTS 1"DEEP WITH ASHARP KNIFE. N.T.S.SECTION PER SCHEDULE(6-24" TYP.) N.T.S.SECTIONSPADE EDGE PLANT BED EDGE DETAILDETAIL DETAILDETAILDETAIL DETAILDETAIL ORNAMENTAL GRASS PLANTINGN.T.S.SECTION PER SCHEDULE(15-36" TYP.) DETAIL 2 3 4 5 6 7 8 PLANT TREE AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE. PLANTSLIGHTLY HIGHER THAN SURROUNDINGFINISHED GRADE. WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING. REMOVE 'V' CROTCHES, STUBS, DOUBLELEADERS AND OVERLAPPING / RUBBING PRUNEPLANTS (IF NEEDED) ONLY AFTER PLANTING.PRUNING IS SUBJECT TO TIME OF YEAR, ANDSPECIFIC TREE SPECIES.WRAP TREE IN FALL FOR PROTECTION FROMDEER (IF APPLICABLE).3" DEPTH WOOD MULCH OVER SOIL RING;DO NOT PLACE MULCH AGAINST TREE TRUNK.REMOVE BURLAP, SYNTHETIC TWINE, AND WIRECAGE FROM TOP 13 OF ROOTBALL. SCOREREMAINING 23 OF BURLAP ONCE TREE IS IN PLACE,AND STRAIGHTENED. CAREFULLY BENDREMAINING CAGE DOWN TO BOTTOM OF HOLE.INSTALL ONE (1) SLOW RELEASE FERTILIZERPACKET PER 1" CALIPER OF TREE. PLACEAGAINST ROOT BALL.DIG HOLE 2X WIDER THAN DIAMETER OF ROOTBALL. BACK FILL WITH SPECIFIED SOIL - AVOIDAIR POCKETS BY TAMPING SOIL MIXTURE IN4" LIFTS.EXISTING SUBGRADE PLANT TREE AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE. PLANTSLIGHTLY HIGHER THAN SURROUNDINGFINISHED GRADE.REMOVE STUBS, AND OVERLAPPING, BROKENOR RUBBING BRANCHES. PRUNE PLANTS (IFNEEDED) ONLY AFTER PLANTING.PRUNING IS SUBJECT TO TIME OF YEAR, ANDSPECIFIC TREE SPECIES.3" DEPTH WOOD MULCH OVER SOIL RING;DO NOT PLACE MULCH AGAINST TREE TRUNK.REMOVE BURLAP, SYNTHETIC TWINE, AND WIRECAGE FROM TOP 13 OF ROOTBALL. SCOREREMAINING 23 OF BURLAP ONCE TREE IS IN PLACE,AND STRAIGHTENED. CAREFULLY BENDREMAINING CAGE DOWN TO BOTTOM OF HOLE.INSTALL ONE (1) SLOW RELEASE FERTILIZERPACKET PER 24" HEIGHT OF TREE. PLACEAGAINST ROOT BALL.DIG HOLE 2X WIDER THAN DIAMETER OF ROOTBALL. BACK FILL WITH SPECIFIED SOIL - AVOIDAIR POCKETS BY TAMPING SOIL MIXTURE IN4" LIFTS.EXISTING SUBGRADEWATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING. PRUNE OUT DEAD & BROKEN BRANCHES; RETAINNORMAL PLANT SHAPE.3" DEPTH WOOD MULCH OVER SOIL RING; DO NOTPLACE MULCH AGAINST STEMS, OR BURY BOTTOMBRANCHES.REMOVE BURLAP AND SYNTHETIC TWINE FROM TOP13 OF ROOTBALL. SCORE REMAINING 23 OF BURLAP.INSTALL ONE SLOW RELEASE FERTILIZER PACKETSAGAINST ROOT BALL.DIG HOLE 2X WIDER THAN DIAMETER OF ROOT BALL.BACK FILL WITH SPECIFIED PLANTING MIX - AVOID AIRPOCKETS BY TAMPING MIXTURE IN 4" LIFTS.WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING. PLANT SHRUB AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE.PRUNE OUT DEAD & BROKEN BRANCHES; RETAINNORMAL PLANT SHAPE.3" DEPTH WOOD MULCH OVER SOIL RING; DO NOTPLACE MULCH AGAINST STEMS, OR BURY BOTTOMBRANCHES.REMOVE BURLAP AND SYNTHETIC TWINE FROM TOP13 OF ROOTBALL. SCORE REMAINING 23 OF BURLAP.INSTALL ONE SLOW RELEASE FERTILIZER PACKETSAGAINST ROOT BALL.DIG HOLE 2X WIDER THAN DIAMETER OF ROOT BALL.BACK FILL WITH SPECIFIED PLANTING MIX - AVOID AIRPOCKETS BY TAMPING MIXTURE IN 4" LIFTS.WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING.LANDSCAPE FABRIC CAREFULLY REMOVEPLANT FROM PLASTIC POT& SCORE ROOTS 1" DEEPWITH A SHARP KNIFE. USE EDGING AROUNDPERIMETER OF GRAVELMULCH AREA OR ALONGBEDLINE PLANT SHRUB AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE.PRUNE OUT DEAD & BROKEN BRANCHES; RETAINNORMAL PLANT SHAPE.3" DEPTH WOOD MULCH OVER SOIL RING; DO NOTPLACE MULCH AGAINST STEMS, OR BURY BOTTOMBRANCHES.REMOVE BURLAP AND SYNTHETIC TWINE FROM TOP13 OF ROOTBALL. SCORE REMAINING 23 OF BURLAP.INSTALL ONE SLOW RELEASE FERTILIZER PACKETSAGAINST ROOT BALL.DIG HOLE 2X WIDER THAN DIAMETER OF ROOT BALL.BACK FILL WITH SPECIFIED PLANTING MIX - AVOID AIRPOCKETS BY TAMPING MIXTURE IN 4" LIFTS.WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING. SPACING OF PERENNIALS WILL VARY ON THE VARIETYOF PERENNIAL SELECTED.SPACING PLAN - IF NOT INDICATED ON PLANT & MATERIALLIST. WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING.PLANTING MIX DEPTH OF 9" TO BE ROTO-TILLED AT ALLPERENNIAL AREAS.2" DOUBLE SHREDDED HARDWOOD MULCH OR LEAF COMPOST.REMOVE BROKEN, BENT, DEAD OR DISEASEDLEAVES/STEMS AFTER PLANTING.CAREFULL REMOVE PLANT FROM CONTAINER;SCORE ROOTS ON ALL SIDES; HAND TAMP INTOPLACE TO PROTECT PLANT.PLANT SHRUB AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE.LANDSCAPE FABRICSCARIFY EXISTING SUBGRADE SPACING OF PERENNIALS WILL VARY ON THE VARIETYOF PERENNIAL SELECTED.SPACING PLAN - IF NOT INDICATED ON PLANT & MATERIALLIST. WATER IMMEDIATELY AFTER PLANTING WITH ATHOROUGH AND DEEP, SLOW RELEASE WATERING.PLANTING MIX DEPTH OF 9" TO BE ROTO-TILLED AT ALLPERENNIAL AREAS.2" DBL SHREDDED HARDWOOD MULCH OR LEAF COMPOST.REMOVE BROKEN, BENT, DEAD OR DISEASEDLEAVES/STEMS AFTER PLANTING.CAREFULL REMOVE PLANT FROM CONTAINER;SCORE ROOTS ON ALL SIDES; HAND TAMP INTOPLACE TO PROTECT PLANT.PLANT SHRUB AT SAME LEVEL AS PREVIOUSGROWING CONDITION AT ROOT FLARE.LANDSCAPE FABRICSCARIFY EXISTING SUBGRADE TOP OF MULCH SHOULD BE CRESTED 1-2" ABOVETURF FOR POSITIBE DRAINGE. SLOPE GRADUALLY.BEDLINES ARE TO BE CUT CRISP AS PER PLAN. ACLEAN DEFINITION BETWEEN TURF AND PLANTINGBED IS REQUIRED.3" SHREDDED HARDWOOD MULCH BEDTOPSOIL/PLANTING MIXTURFGRASS (TYPICAL) 1. Contractor responsible for contacting Diggers Hotline (811 or 800-242-8511) to have site marked prior to excavation or planting.2. Contractor to verify all plant quantities shown on Plant & Material List and landscape planting symbols and report any discrepancies to Landscape Architect orGeneral Contractor.3. All plantings shall comply with standards as described in American Standard of Nursery Stock - Z60.1 ANSI (latest version). Landscape Architect reservesthe right to inspect, and potentially reject any plants that are inferior, compromised, undersized, diseased, improperly transported, installed incorrectly ordamaged. No sub-standard "B Grade" or "Park Grade" plant material shall be accepted. Plant material shall originate from nursery(ies) with a similar climate asthe planting site.4. Any potential plant substitutions must be approved by Landscape Architect or Owner. All plants must be installed as per sizes indicated on Plant & MaterialSchedule, unless approved by Landscape Architect. Any changes to sizes shown on plan must be submitted in writing to the Landscape Architect prior toinstallation.5. Topspoil in Parking Lot Islands (if applicable): All parking lot islands to be backfilled with topsoil to a minimum depth of 12" to insure long-term plant health.Topsoil should be placed within 3" of finish grade by General Contractor / Excavation Contractor during rough grading operations/activity. The landscapecontractor shall be responsible for the fine grading of all disturbed areas, planting bed areas, and lawn areas. Crown all parking lot islands a minimum of 4" toprovide proper drainage, unless otherwise specified.6. Tree Planting: Plant all trees slightly higher than finished grade at the root flare. Remove excess soil from the top of the root ball, if needed. Remove anddiscard non-biodegradable ball wrapping and support wire. Removed biodegradable burlap and wire cage (if present) from the top 13 of the rootball and carefullybend remaining wire down to the bottom of the hole. Once the tree has been placed into the hole and will no longer be moved, score the remaining 23 of theburlap and remove the twine. Provide one slow release fertilizer packets (per 1" caliper) for each tree planted.7. Tree Planting: Backfill tree planting holes 80% existing soils removed from excavation and 20% Soil Amendments (see Note 11). Avoid air pockets and donot tamp soil down. Discard any gravel, rocks, heavy clay, or concrete pieces. When hole is 23 full, trees shall be watered thoroughly, and water left to soak inbefore proceeding to fill the remainder of the hole. Water again to full soak in the new planting. Each tree shall receive a 3" deep, 4-5' diameter (see plantingdetails or planting plan) shredded hardwood bark mulch ring / saucer around all trees. Do not build up any mulch onto the trunk of any tree. Trees that areinstalled incorrectly will be replaced at the time and expense of the Landscape Contractor.8. Shrub Planting: All shrubs to be planted in groupings as indicated on the Landscape Plan. Install with the planting of shrubs a 5050 mix of Soil Amendmentswith blended, pulverized topsoil. Install topsoil into all plant beds as needed to achieve proper grade and displace undesirable soils (see planting detail).Remove all excessive gravel, clay and stones from plant beds prior to planting. When hole(s) are 23 full, shrubs shall be watered thoroughly, and water left tosoak in before proceeding. Provide slow-release fertilizer packets at the rater of 1 per 24" height/diameter of shrub at planting.9. Mulching: All tree rings to receive a 3" deep layer of high quality shredded hardwood bark mulch (not pigment dyed or enviro-mulch). All shrub planting andperennial planting bed areas (groupings) shall receive a 2" layer of double-shredded hardwood bark mulch, and groundcover areas a 2" layer of the same mulch.Do not mulch annual flower beds (if applicable). Do not allow mulch to contact plant stems and tree trunks.10. Edging: All planting beds shall be edged with a 4" deep spade edge using a flat landscape spade or a mechanical edger. Bedlines are to be cut crisp,smooth as per plan. A clean definition between landscape beds and lawn is required. Pack mulch against lawn edge to hold in place.11. Plant bed preparation/Soil Amendment composition: All perennial, groundcover and annual areas (if applicable) are required to receive a blend of organicsoil (Soil Amendments) amendments prior to installation. Roto-till the following materials at the following ratio, into existing soil beds or installed topsoil beds to adepth of approximately 8"-10". Containerized and balled & burlapped plant material should be back-filled with amended soil:Per 100 SF of bed area (Soil Amendment composition):34 CY Peat Moss or Mushroom Compost34 CY blended/pulverized Topsoil14 CY composted manureIn roto-tilled beds only, also include in above mixture:2 lbs Starter Fertilizer12. Installation preparation for all seeded areas: remove/kill off any existing unwanted vegetation prior to seeding. Prepare the topsoil (if adequate or provideas in item #6 above) and seed bed by removing all surface stones 1" or larger. Apply a starter fertilizer (20-10-5, or approved comparable) and specified seeduniformly at the specified rate, and provide mulch covering suitable to germinate and establish turf. Provide seed and fertilizer specifications to LandscapeArchitect and Owner prior to installation. Erosion control measures are to be used in swales and on slopes in excess of 1:3 and where applicable (see CivilEngineering Drawings). Methods of installation may vary are the discretion of the Landscape Contractor on his/her responsibility to establish and guarantee asmooth, uniform, quality turf. A minimum of 2" of blended, prepared and non-compacted topsoil is required for all lawn areas. If straw mulch is used as a mulchcovering, a tackifier may be necessary to avoid wind dispersal of mulch covering. Marsh hay containing reed canary grass is NOT acceptable as a mulchcovering.An acceptable quality seed installation is defined as having:No bare spots larger than one (1) square footNo more than 10% of the total area with bare areas larger than one (1) square footA uniform coverage through all turf areas13. Warranty and Replacements: All plantings are to be watered thoroughly at the time of planting, through construction and upon completion of project asrequired. Trees, Evergreens, and Shrubs (deciduous and evergreen) shall be guaranteed (100% replacement) for a minimum of one (1) year from the date ofproject completion. Perennials, groundcovers, and ornamental grasses shall be guaranteed for a minimum of one (1) growing season. Perennials,groundcovers, and ornamental grasses planted after September 15th shall be guaranteed through May 31st of the following year. Only one replacement perplant will be required during the warranty period, except for losses or replacements due to failure to comply with specified requirements. Watering and generalongoing maintenance instructions are to be supplied by the Landscape Contractor to the Owner upon completion of the project.14. The Landscape Contractor is responsible for the watering and maintenance of all landscape areas for a period of 45 days after the substantial completion ofthe landscape installation. This shall include all trees, shrubs, evergreens, perennials, ornamental grasses, turf grass, no-mow grass, and native prairie seedmix / stormwater seed mix. Work also includes weeding, edging, mulching (only if required), fertilizing, trimming, sweeping up grass clippings, pruning anddeadheading.15. Project Completion: Landscape Contractor is responsible to conduct a final review of the project, upon completion, with the Landscape Architect, Client orOwner / Client Representative, and the General Contractor to answer questions, provide written care instructions for new plantings and turf, and insure that allspecifications have been met. N.T.S.DETAILSTONE MAINTENANCE DRIP EDGE DETAILSECTIONTOPSOIL / PLANTING MIXSUBGRADEFILTER FABRIC1.5" LIMESTONE SCREENINGS ORDECOMPOSED GRANITE (COMPACTED) 18" x 4" ALUMINUM EDGE RESTRAINT; MILL FINISH;STAKED EVERY 24"TOP OF GRAVEL SHOULD BE APPROXIMATELY 12"BELOW TOP OF THE EDGE RESTAINT3" (+/-) STONE / GRAVEL MEDIUM (SEE PLAN ORMATERIAL SCHEDULE FOR TYPE)PLANTS / LAWNBUILDING FOUNDATION 9 SHEET NUMBERDATEPROJECT NUMBER SHEET TITLE PROJECT MANAGER PROJECT DESCRIPTIONDATEISSUANCE AND REVISIONS 7.22.2629-027WDH 7.01.26FIRST ISSUE JOHNSONFINANCIALGROUP17740 W.Bluemound Rd.Brookfield, WI Information contained herein is based on survey information, fieldinspection, and believed to be accurate. 7.08.26OWNER COMMENTS7.22.26REVISED SITE PLAN L 1.5LANDSCAPEDETAILS,NOTES &SCHEDULESPLANTING & HARDSCAPE DETAILS PLANT & MATERIAL SCHEDULELANDSCAPE GENERAL NOTES HELLER &ASSOCIATES, LLCL A N D S C A P E A R C H I T E C T U R EP.O. Box 1359Lake Geneva, Wisconsin 53147-1359ph 262.639.9733david@wdavidheller.comwww.wdavidheller.com REG-03 REG-03 Luminaire ScheduleQtyLabelArrangementLLFMFRDescription Lum. WattsTotalWattsLum. Lumens3 OASingle0.950LITHONIADSX1 LED P2 40K T5M MVOLT G1 + 17' POLE + 3' BASE67.79203.3793529 OBSINGLE0.900LITHONIALDN6 ALO2 SWW1 LO6AR LSS 80CRI (2000LM)2522526342 OCSINGLE0.900LITHONIAWDGE2 LED P3 40K 80CRI T3M MVOLT SRM DBLXD32.137564.27532162 ODSINGLE0.900LITHONIAWF6 LED 30K40K50K MVOLT 90CRI 4000K13.52712143 OF-HSINGLE0.900LITHONIADSX1 LED P2 40K T4M MVOLT HS G1 + 17' POLE + 3' BASE7021067582 OF2-HBack-Back0.900LITHONIADSX1 LED P2 40K T4M MVOLT HS G1 2@180 + 17' POLE + 3'BASE 7028067582 OGSingle0.950LITHONIADSX1 LED P2 40K BLC3 MVOLT G1 + 17' POLE + 3' BASE67.79135.5865142 OKSINGLE0.900LITHONIAWDGE2 LED P1 xxK 80CRI T2M MVOLT SRM DBLXD11.165822.33212644 OLSINGLE0.900LITHONIAWDGE2 LED P0 xxK 80CRI T2M MVOLT SRM DBLXD6.894627.578728 Calculation SummaryLabel CalcTypeUnitsAvgMaxMinAvg/MinMax/MinAT GRADEIlluminanceFc 1.4325.40.0N.A.N.A.PRESUMED PROPERTY LINEIlluminanceFc 0.080.30.0N.A.N.A.DRIVE THRU CANOPYIlluminanceFc 16.2525.45.03.255.08PARKING AND DRIVESIlluminanceFc 2.2325.40.211.15127.00 ODMH: 10ODMH: 10 OCMH: 12OCMH: 12OBMH: 12.5OBMH: 12.5OBMH: 12.5OBMH: 12.5OBMH: 12.5OBMH: 12.5OBMH: 12.5OBMH: 12.5 OGMH: 20 OGMH: 20 OAMH: 20OF-HMH: 20 OBMH: 12.5 OF-HMH: 20OF-HMH: 20 OF2-HMH: 20OF2-HMH: 20 OAMH: 20OAMH: 20 OKMH: 12 OKMH: 12 OLMH: 12OLMH: 12OLMH: 12OLMH: 12 0.20.20.10.10.10.00.00.00.00.10.20.30.30.30.40.30.30.30.30.30.30.20.20.10.10.00.00.00.10.20.40.50.50.60.60.60.60.50.50.40.40.30.20.10.10.00.00.10.30.50.60.70.80.80.80.80.70.60.60.50.50.40.20.10.00.00.10.30.50.70.91.01.11.21.21.11.11.21.52.11.91.10.70.40.30.20.40.60.91.11.21.31.41.41.41.51.72.02.52.31.61.10.70.40.30.60.91.11.21.31.41.21.51.51.51.82.12.32.21.71.20.70.40.51.11.41.51.41.31.41.41.51.41.41.51.61.61.51.31.00.60.41.11.72.01.81.41.21.31.31.31.21.21.21.21.00.90.90.70.50.31.72.32.31.91.31.11.21.31.31.21.11.00.90.70.60.50.50.50.31.82.92.62.01.31.01.21.92.11.71.41.41.31.11.10.90.80.90.51.82.72.51.91.20.91.55.56.42.31.61.51.61.31.41.11.01.20.81.62.75.04.23.6 0.80.51.05.320.319.216.2 1.10.70.55.025.421.217.4 0.80.60.42.410.78.77.4 0.90.50.40.70.90.90.7 0.80.50.71.11.31.10.6 0.70.51.41.82.01.50.91.01.11.01.00.9 1.10.72.02.42.31.81.21.11.52.02.43.43.9 0.80.51.93.12.62.01.41.41.72.02.42.62.8 0.60.41.93.02.62.11.51.61.82.02.12.12.22.12.42.53.32.80.30.50.31.92.32.42.11.71.71.92.02.12.12.12.22.12.22.11.81.40.90.21.31.82.22.01.81.81.72.12.22.22.01.81.91.61.31.00.80.50.30.71.11.61.71.71.81.92.22.32.32.11.91.61.31.00.70.50.30.20.50.91.21.61.82.12.32.52.62.62.42.11.81.41.10.70.50.20.10.40.81.11.52.12.52.83.03.23.12.92.62.21.71.20.80.50.30.10.40.81.11.62.22.83.23.43.53.53.33.02.51.91.30.90.50.30.10.40.71.01.52.13.03.83.83.63.63.73.52.71.91.20.80.50.30.10.40.61.01.62.23.45.04.33.73.94.54.52.91.91.30.80.50.30.20.30.60.91.31.93.14.33.93.43.54.24.22.71.71.20.80.50.30.20.30.50.81.42.12.83.43.53.53.63.53.32.71.91.20.70.50.30.10.30.60.91.52.32.93.33.63.93.83.63.22.82.11.30.80.50.30.20.30.60.91.52.22.93.23.53.83.83.53.22.82.11.30.80.50.30.10.30.50.81.31.92.73.23.43.43.43.43.12.61.91.10.70.40.20.10.20.40.61.01.42.23.22.92.62.73.03.02.01.40.90.60.30.20.10.10.20.30.40.71.21.61.41.21.31.61.61.10.60.40.30.20.10.10.00.00.10.10.20.30.30.30.30.30.30.30.20.10.10.10.00.00.00.00.00.00.00.10.10.10.10.10.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.20.30.20.20.20.20.20.20.10.00.00.00.00.00.00.00.00.10.10.10.10.20.20.20.20.20.20.20.20.20.20.10.10.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.20.20.20.20.20.20.20.20.10.10.00.00.00.00.00.00.00.0 REVISIONS#DATECOMMENTSDRAWN BY : DATE :SCALE : BBJULY 20, 20261" = 25'-0" JOHNSON FINANCIAL GROUPBROOKFIELD, WISITE LIGHTING LAYOUT NOTES1.LIGHTING AND PHOTOMETRIC LAYOUT PROVIDED ARE INTENDED FOR DESIGN INTENT ONLY. THIS DOCUMENT IS NOT INTENDED FOR CONSTRUCTION ORINSTALLATION PURPOSES. 2.ACTUAL FIELD CONDITIONS, ARCHITECTURAL ELEMENTS, AND FINAL EQUIPMENT SELECTIONS MAY AFFECT LIGHTING PERFORMANCE AND MUST BE VERIFIEDBY THE CUSTOMER. ENTERPRISE LIGHTING IS NOT RESPONSIBLE FOR VARIATION IN INSTALLED LIGHT LEVELS DUE TO UNVERIFIED FIELD CONDITIONS.3.STANDARD REFLECTANCE OF 80/50/20 FOR CLOSED CEILINGS AND 50/50/20 FOR OPEN CEILINGS UNLESS NOTED OTHERWISE.4.STANDARD CALC POINTS @ 30” AFF UNLESS NOTED OTHERWISE, POINTS ARE @ GRADE FOR OUTDOOR POINTS.5.EGRESS CALC POINTS ARE @ FINISHED FLOOR. 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 1 of 10 COMMERCIAL OUTDOOR Ordering Information EXAMPLE: DSX1 LED P7 40K 70CRI T3M MVOLT SPA NLTAIR2 PIRHN DDBXD DSX1 LED Series LEDs Color temperature 2 Color Rendering Index 2 Distribution Voltage Mounting DSX1 LED Forward optics P1 P6 P2 P7 P3 P8 P4 P9 P5 Rotated optics P10 1 P12 1 P11 1 P13 1 (this section 70CRI only) 30K 3000K 40K 4000K 50K 5000K 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K 70CRI 70CRI 70CRI 80CRI 80CRI 80CRI 80CRI 80CRI AFR Automotive front row T1S Type I short T2M Type II medium T3M Type III medium T3LG Type III low glare 3 T4M Type IV medium T4LG Type IV low glare 3 TFTM Forward throw medium T5M Type V medium T5LG Type V low glare T5W Type V wide BLC3 Type III backlight control 3 BLC4 Type IV backlight control 3 LCCO Left corner cutoff 3 RCCO Right corner cutoff 3 MVOLT (120V-277V) 4 HVOLT (347V-480V) 5,6 XVOLT (277V - 480V) 7,8 120 16, 26 208 16, 26 240 16, 26 277 16, 26 347 16, 26 480 16, 26 Shipped included SPA Square pole mounting (#8 drilling) RPA Round pole mounting (#8 drilling) SPA5 Square pole mounting #5 drilling 9 RPA5 Round pole mounting #5 drilling 9 SPA8N Square narrow pole mounting #8 drilling WBA Wall bracket 10 MA Mast arm adapter (mounts on 2 3/8" OD horizontal tenon) Control options Other options Finish (required) Shipped installed NLTAIR2 PIRHN nLight AIR gen 2 enabled with bi-level motion / ambient sensor, 8-40’ mounting height, ambient sensor enabled at 2fc. 11, 12, 20, 21 PIR High/low, motion/ambient sensor, 8-40’ mounting height, ambient sensor enabled at 2fc 13, 20, 21 PER NEMA twist-lock receptacle only (controls ordered sepa- rate) 14 PER5 Five-pin receptacle only (controls ordered separate)14, 21 PER7 Seven-pin receptacle only (controls ordered separate) 14, 21 FAO Field adjustable output 15, 21 BL30 Bi-level switched dimming, 30% 16, 21 BL50 Bi-level switched dimming, 50% 16, 21 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) 17 DS Dual switching 18, 19, 21 Shipped installed SPD20KV 20KV surge protection HS Houseside shield (black finish standard) 22 L90 Left rotated optics 1 R90 Right rotated optics 1 CCE Coastal Construction 23 HA 50°C ambient operation 24 BAA Buy America(n) Act and/or Build America Buy America Qualified SF Single fuse (120, 277, 347V) 26 DF Double fuse (208, 240, 480V) 26 Shipped separately EGSR External Glare Shield (reversible, field install required, matches housing finish) BSDB Bird Spikes (field install required) DDBXD Dark Bronze DBLXD Black DNAXD Natural Aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white D-Series Size 1 LED Area Luminaire Catalog Number Notes Type Introduction The modern styling of the D-Series features a highly refined aesthetic that blends seamlessly with its environment. The D-Series offers the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. D-Series outstand- ing photometry aids in reducing the number of poles required in area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Hit the Tab key or mouse over the page to see all interactive elements. H2 L W H1 Specifications EPA: 0.69 ft2 (0.06 m2) Length: 32.71" (83.1 cm) Width: 14.26" (36.2 cm) Height H1: 7.88" (20.0 cm) Height H2: 2.73" (6.9 cm) Weight: 34 lbs (15.4 kg) Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect. *See ordering tree for detailsDesign Select options indicated by this color background. H2 L W H1 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 2 of 10 COMMERCIAL OUTDOOR Accessories Ordered and shipped separately. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 25 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 25 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 25 DSHORT SBK Shorting cap 25 DSX1HS P# House-side shield (enter package number 1-13 in place of #) DSXRPA (FINISH) Round pole adapter (#8 drilling, specify finish) DSXSPA5 (FINISH) Square pole adapter #5 drilling (specify finish) DSXRPA5 (FINISH) Round pole adapter #5 drilling (specify finish) DSX1EGSR (FINISH) External glare shield (specify finish) DSX1BSDB (FINISH) Bird spike deterrent bracket (specify finish) Shield Accessories External Glare Shield (EGSR) Tenon O.D. Mounting Single Unit 2 @ 180 2 @ 90 3 @ 90 3 @120 4 @ 90 2-3/8" RPA AS3-5 190 AS3-5 280 AS3-5 290 AS3-5 390 AS3-5 320 AS3-5 490 2-7/8" RPA AST25-190 AST25-280 AST25-290 AST25-390 AST25-320 AST25-490 4" RPA AST35-190 AST35-280 AST35-290 AST35-390 AST35-320 AST35-490 Tenon Mounting Slipfitter Drilling Top of Pole 0.563" 2.650" 1.325" 0.400" (2 PLCS) Template #8 Ordering Information NOTES 1 Rotated optics available with packages P10, P11, P12 and P13. Must be combined with option L90 or R90. 2 30K, 40K, and 50K available in 70CRI and 80CRI. 27K and 35K only available with 80CRI. Contact Technical Support for other possible combinations. 3 T3LG, T4LG, BLC3, BLC4, LCCO, RCCO not available with option HS. 4 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 5 HVOLT driver operates on any line voltage from 347-480V (50/60 Hz). 6 HVOLT not available with package P1 and P10 when combined with option NLTAIR2 PIRHN or option PIR. 7 XVOLT operates with any voltage between 277V and 480V (50/60 Hz). 8 XVOLT not available in packages P1 or P10. XVOLT not available with P1 ,P2, P5, P7, P9, P10, P11 and P13 when combined with option NLTAIR2 PIRHN or PIR. XVOLT not available with fusing (SF or DF). 9 SPA5 and RPA5 for use with #5 drilling only (Not for use with #8 drilling). 10 WBA cannot be combined with Type 5 distributions plus photocell (PER). 11 NLTAIR2 and PIRHN must be ordered together. For more information on nLight AIR2 visit this link 12 NLTAIR2 PIRHN not available with other controls including PIR, PER, PER5, PER7, FAO, BL30, BL50, DMG and DS. NLTAIR2 PIRHN not available with P1 and P10 using HVOLT. 13 PIR not available with NLTAIR2 PIRHN, PER, PER5, PER7, FAO BL30, BL50, DMG and DS. 14 PER/PER5/PER7 not available with NLTAIR2 PIRHN, PIR, BL30, BL50, FAO, DMG and DS. Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included. 15 FAO not available with other dimming control options NLTAIR2 PIRHN, PIR, PER5, PER7, BL30, BL50, DMG and DS. 16 BL30 and BL50 are not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, FAO, DMG and DS. BL30 or BL50 must specify 120 or 277V. 17 DMG not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DS. 18 DS not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DMG. 19 DS requires (2) separately switched circuits. DS provides 50/50 fixture operation via (2) different sets of leads using (2) drivers. DS only available with packages P8, P9, P10, P11, P12 and P13. 20 Reference Motion Sensor Default Settings table on page 4 to see functionality. 21 Reference Controls Options table on page 4. 22 HS not available with T3LG, T4LG, BLC3, BLC4, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information. 23 CCE option not available with option BS and EGSR. Contact Technical Support for availability. 24 Option HA not available with performance packages P4, P5, P7, P8, P9 and P13. 25 Requires luminaire to be specified with PER, PER5 or PER7 option. See Controls Table on page 4. 26 Single fuse (SF) requires 120V, 277V, or 347V. Double fuse (DF) requires 208V, 240V or 480V. XVOLT not available with fusing (SF or DF). HANDHOLE ORIENTATION A Handhole B C D 1.75" for aluminum poles 2.75" for other pole types Fixture Quantity & Mounting Configuration Single DM19 2 @ 180 DM28 2 @ 90 DM29 3 @ 90 DM39 3 @ 120 DM32 4 @ 90 DM49 Mounting Type DSX1 with SPA 0.69 1.38 1.23 1.54 --- 1.58 DSX1 with SPA5, SPA8N 0.70 1.40 1.30 1.66 --- 1.68 DSX1 with RPA, RPA5 0.70 1.40 1.30 1.66 1.60 1.68 DSX1 with MA 0.83 1.66 1.50 2.09 2.09 2.09 DSX1 Area Luminaire - EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. House Side Shield (HS) Minimum Acceptable Outside Pole Dimension SPA #8 3.5" 3.5" 3.5" 3.5" 3.5" RPA #8 3" 3" 3" 3" 3" 3" SPA5 #5 3" 3" 3" 3" 3" RPA5 #5 3" 3" 3" 3" 3" 3" SPA8N #8 3" 3" 3" 3" 3" Mounting Option Drilling Template Single 2 @ 180 2 @ 90 3 @ 90 3 @ 120 4 @ 90 Head Location Side B Side B & D Side B & C Side B, C & D Round Pole Only Side A, B, C & D Drill Nomenclature #8 DM19AS DM28AS DM29AS DM39AS DM32AS DM49AS 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 3 of 10 COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s homepage. Photometric Diagrams Isofootcandle plots for the DSX1 LED P9 40K 70CRI. Distances are in units of mounting height (25’). LEGEND 0.1 fc 0.5 fc 1.0 fc T1S T2M T3M 4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3LG T4M TFTM T4LG T5M T5W T5LG AFR BLC3 BLC4 LCCO RCCO 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 43216 5 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 4 of 10 COMMERCIAL OUTDOOR Performance Data Current (A) Performance Package LED Count Drive Current (mA) Wattage 120V 208V 240V 277V 347V 480V Forward Optics (Non-Rotated) P1 30 530 51 0.42 0.24 0.21 0.18 0.15 0.11 P2 30 700 68 0.56 0.33 0.28 0.24 0.20 0.14 P3 30 1050 104 0.85 0.49 0.43 0.37 0.29 0.21 P4 30 1250 125 1.03 0.60 0.52 0.45 0.36 0.26 P5 30 1400 142 1.15 0.66 0.58 0.50 0.40 0.29 P6 40 1250 167 1.38 0.79 0.69 0.60 0.48 0.34 P7 40 1400 188 1.54 0.89 0.77 0.67 0.53 0.38 P8 60 1100 216 1.80 1.04 0.90 0.78 0.62 0.45 P9 60 1400 279 2.31 1.33 1.15 1.00 0.80 0.58 Rotated Optics (Requires L90 or R90) P10 60 530 101 0.84 0.49 0.42 0.37 0.29 0.21 P11 60 700 135 1.12 0.65 0.56 0.49 0.39 0.28 P12 60 1050 206 1.72 0.99 0.86 0.74 0.59 0.43 P13 60 1400 279 2.30 1.33 1.15 1.00 0.79 0.57 Electrical Load Motion Sensor Default Settings Option Unoccupied Dimmed Level High Level (when occupied) Phototcell Operation Dwell Time Ramp-up Time Dimming Fade Rate PIR 30% 100% Enabled @ 2FC 7.5 min 3 sec 5 min NLTAIR2 PIRHN 30% 100% Enabled @ 2FC 7.5 min 3 sec 5 min Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Ambient Lumen Multiplier 0°C 32°F 1.04 5°C 41°F 1.04 10°C 50°F 1.03 15°C 50°F 1.02 20°C 68°F 1.01 25°C 77°C 1.00 30°C 86°F 0.99 35°C 95°F 0.98 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF , use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours Lumen Maintenance Factor 0 1.00 25,000 0.95 50,000 0.90 100,000 0.81 Controls Options Nomenclature Description Functionality Primary control device Notes FAO Field adjustable output device installed inside the luminaire; wired to the driver dimming leads. Allows the luminaire to be manually dimmed, effectively trimming the light output. FAO device Cannot be used with other controls options that need the 0-10V leads DS (not available on DSX0) Drivers wired independently for 50/50 luminaire operation The luminaire is wired to two separate circuits, allowing for 50/50 operation. Independently wired drivers Requires two separately switched circuits. Consider nLight AIR as a more cost effective alternative. PER5 or PER7 Twist-lock photocell receptacle Compatible with standard twist-lock photocells for dusk to dawn operation, or advanced control nodes that provide 0-10V dimming signals. Twist-lock photocells such as DLL Elite or advanced control nodes such as ROAM. Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are capped inside luminaire. Cannot be used with other controls options that need the 0-10V leads. PIR Motion sensor with integral photocell. Sensor suitable for 8' to 40' mounting height. Luminaires dim when no occupancy is detected. Acuity Controls rSBG Cannot be used with other controls options that need the 0-10V leads. NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing, photocell and wireless communication. Motion and ambient light sensing with group response. Scheduled dimming with motion sensor over-ride when wirelessly connected to the nLight Eclypse. nLight Air rSBG nLight AIR sensors can be programmed and commissioned from the ground using the ClAIRity Pro app. Cannot be used with other controls options that need the 0-10V leads. BL30 or BL50 Integrated bi-level device that allows a second control circuit to switch all light engines to either 30% or 50% light output BLC device provides input to 0-10V dimming leads on all drivers providing either 100% or dimmed (30% or 50%) control by a secondary circuit BLC UVOLT1 BLC device is powered off the 0-10V dimming leads, thus can be used with any input voltage from 120 to 480V 70 CRI 80CRI 90CRI Lumen Multiplier Availability Lumen Multiplier Availability Lumen Multiplier Availability 5000K 102% Standard 92% Extended lead-time 71% (see note) 4000K 100% Standard 92% Extended lead-time 67% (see note) 3500K 100% (see note) 90% Extended lead-time 63% (see note) 3000K 96% Standard 87% Extended lead-time 61% (see note) 2700K 94% (see note) 85% Extended lead-time 57% (see note) LED Color Temperature / Color Rendering Multipliers Note: Some LED types are available as per special request. Contact Technical Support for more information. *Note: Calculated values are based on original performance package data. When calculating new values for given FAO position, use maximum published values by package listed on specification sheet (input watts and lumens by optic type). FAO Position % Wattage % Lumen Output 8 100% 100% 7 93% 95% 6 80% 85% 5 66% 73% 4 54% 61% 3 41% 49% 2 29% 36% 1 15% 20% FAO Dimming Settings 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 5 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA) Distribution Type 30K 40K 50K (3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P1 51W 30 530 T1S 7,776 1 0 2 153 8,104 1 0 2 159 8,262 1 0 2 162 T2M 7,203 1 0 3 142 7,507 2 0 3 147 7,653 2 0 3 150 T3M 7,287 1 0 3 143 7,594 1 0 3 149 7,742 1 0 3 152 T3LG 6,509 1 0 1 128 6,783 1 0 1 133 6,916 1 0 1 136 T4M 7,395 1 0 3 145 7,707 1 0 3 151 7,857 1 0 3 154 T4LG 6,726 1 0 1 132 7,010 1 0 1 138 7,146 1 0 1 140 TFTM 7,446 1 0 3 146 7,760 1 0 3 152 7,912 1 0 3 155 T5M 7,609 3 0 2 149 7,930 3 0 2 156 8,084 3 0 2 159 T5W 7,732 3 0 2 152 8,058 4 0 2 158 8,215 4 0 2 161 T5LG 7,631 3 0 1 150 7,953 3 0 1 156 8,108 3 0 1 159 BLC3 5,300 0 0 2 104 5,524 0 0 2 109 5,631 0 0 2 111 BLC4 5,474 0 0 3 108 5,705 0 0 3 112 5,816 0 0 3 114 RCCO 5,348 0 0 2 105 5,573 0 0 2 109 5,682 0 0 2 112 LCCO 5,348 0 0 2 105 5,573 0 0 2 109 5,682 0 0 2 112 AFR 7,776 1 0 2 153 8,104 1 0 2 159 8,262 1 0 2 162 P2 68W 30 700 T1S 9,997 1 0 2 147 10,418 1 0 2 154 10,621 1 0 2 157 T2M 9,260 2 0 3 137 9,651 2 0 3 142 9,839 2 0 3 145 T3M 9,368 2 0 3 138 9,763 2 0 3 144 9,953 2 0 3 147 T3LG 8,368 1 0 2 123 8,721 1 0 2 129 8,891 1 0 2 131 T4M 9,507 2 0 3 140 9,909 2 0 3 146 10,102 2 0 3 149 T4LG 8,647 1 0 2 128 9,012 1 0 2 133 9,187 1 0 2 136 TFTM 9,573 2 0 3 141 9,977 2 0 3 147 10,172 2 0 3 150 T5M 9,782 4 0 2 144 10,195 4 0 2 150 10,393 4 0 2 153 T5W 9,940 4 0 2 147 10,360 4 0 2 153 10,562 4 0 2 156 T5LG 9,810 3 0 1 145 10,224 3 0 1 151 10,423 3 0 1 154 BLC3 6,814 0 0 2 101 7,101 0 0 2 105 7,240 0 0 2 107 BLC4 7,038 0 0 3 104 7,334 0 0 3 108 7,477 0 0 3 110 RCCO 6,875 1 0 2 101 7,165 1 0 2 106 7,305 1 0 2 108 LCCO 6,875 1 0 2 101 7,165 1 0 2 106 7,305 1 0 2 108 AFR 9,997 1 0 2 147 10,418 1 0 2 154 10,621 1 0 2 157 P3 102W 30 1050 T1S 14,093 2 0 2 138 14,687 2 0 2 144 14,973 2 0 2 147 T2M 13,055 2 0 3 128 13,605 2 0 3 133 13,871 2 0 3 136 T3M 13,206 2 0 4 129 13,763 2 0 4 135 14,031 2 0 4 137 T3LG 11,797 2 0 2 115 12,294 2 0 2 120 12,534 2 0 2 123 T4M 13,403 2 0 4 131 13,968 2 0 4 137 14,241 2 0 4 139 T4LG 12,190 2 0 2 119 12,704 2 0 2 124 12,952 2 0 2 127 TFTM 13,496 2 0 4 132 14,065 2 0 4 138 14,339 2 0 4 140 T5M 13,790 4 0 2 135 14,371 4 0 2 141 14,652 4 0 2 143 T5W 14,013 4 0 3 137 14,605 4 0 3 143 14,889 4 0 3 146 T5LG 13,830 3 0 2 135 14,413 3 0 2 141 14,694 3 0 2 144 BLC3 9,606 0 0 2 94 10,011 0 0 2 98 10,206 0 0 2 100 BLC4 9,921 0 0 3 97 10,340 0 0 3 101 10,541 0 0 3 103 RCCO 9,692 1 0 2 95 10,101 1 0 2 99 10,298 1 0 2 101 LCCO 9,692 1 0 2 95 10,101 1 0 2 99 10,298 1 0 2 101 AFR 14,093 2 0 2 138 14,687 2 0 2 144 14,973 2 0 2 147 Lumen Output 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 6 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA) Distribution Type 30K 40K 50K (3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P4 124W 30 1250 T1S 16,416 2 0 3 132 17,109 2 0 3 138 17,442 2 0 3 141 T2M 15,207 3 0 4 123 15,849 3 0 4 128 16,158 3 0 4 130 T3M 15,383 2 0 4 124 16,032 2 0 4 129 16,345 2 0 4 132 T3LG 13,742 2 0 2 111 14,321 2 0 2 116 14,600 2 0 2 118 T4M 15,613 2 0 4 126 16,272 2 0 4 131 16,589 2 0 4 134 T4LG 14,200 2 0 2 115 14,799 2 0 2 119 15,087 2 0 2 122 TFTM 15,721 2 0 4 127 16,384 2 0 4 132 16,703 2 0 4 135 T5M 16,063 4 0 2 130 16,741 4 0 2 135 17,067 4 0 2 138 T5W 16,324 5 0 3 132 17,013 5 0 3 137 17,344 5 0 3 140 T5LG 16,110 3 0 2 130 16,790 4 0 2 135 17,117 4 0 2 138 BLC3 11,190 0 0 3 90 11,662 0 0 3 94 11,889 0 0 3 96 BLC4 11,557 0 0 3 93 12,044 0 0 3 97 12,279 0 0 4 99 RCCO 11,291 1 0 3 91 11,767 1 0 3 95 11,996 1 0 3 97 LCCO 11,291 1 0 3 91 11,767 1 0 3 95 11,996 1 0 3 97 AFR 16,416 2 0 3 132 17,109 2 0 3 138 17,442 2 0 3 141 P5 138W 30 1400 T1S 18,052 2 0 3 131 18,814 2 0 3 136 19,180 2 0 3 139 T2M 16,723 3 0 4 121 17,428 3 0 4 126 17,768 3 0 4 129 T3M 16,917 3 0 4 122 17,630 3 0 4 128 17,974 3 0 4 130 T3LG 15,111 2 0 2 109 15,749 2 0 2 114 16,055 2 0 2 116 T4M 17,169 3 0 5 124 17,893 3 0 5 130 18,242 3 0 5 132 T4LG 15,615 2 0 2 113 16,274 2 0 2 118 16,591 2 0 2 120 TFTM 17,288 2 0 4 125 18,017 2 0 5 130 18,368 3 0 5 133 T5M 17,664 5 0 3 128 18,410 5 0 3 133 18,768 5 0 3 136 T5W 17,951 5 0 3 130 18,708 5 0 3 135 19,073 5 0 3 138 T5LG 17,716 4 0 2 128 18,463 4 0 2 134 18,823 4 0 2 136 BLC3 12,305 0 0 3 89 12,824 0 0 3 93 13,074 0 0 3 95 BLC4 12,709 0 0 4 92 13,245 0 0 4 96 13,503 0 0 4 98 RCCO 12,416 1 0 3 90 12,940 1 0 3 94 13,192 1 0 3 95 LCCO 12,416 1 0 3 90 12,940 1 0 3 94 13,192 1 0 3 95 AFR 18,052 2 0 3 131 18,814 2 0 3 136 19,180 2 0 3 139 P6 165W 40 1250 T1S 21,031 2 0 3 127 21,918 2 0 3 133 22,345 2 0 3 135 T2M 19,482 3 0 4 118 20,303 3 0 4 123 20,699 3 0 4 125 T3M 19,708 3 0 5 119 20,539 3 0 5 124 20,939 3 0 5 127 T3LG 17,604 2 0 2 107 18,347 2 0 2 111 18,704 2 0 2 113 T4M 20,001 3 0 5 121 20,845 3 0 5 126 21,251 3 0 5 129 T4LG 18,191 2 0 2 110 18,959 2 0 2 115 19,328 2 0 2 117 TFTM 20,140 3 0 5 122 20,989 3 0 5 127 21,398 3 0 5 129 T5M 20,579 5 0 3 125 21,447 5 0 3 130 21,865 5 0 3 132 T5W 20,912 5 0 3 127 21,795 5 0 3 132 22,219 5 0 3 134 T5LG 20,638 4 0 2 125 21,509 4 0 2 130 21,928 4 0 2 133 BLC3 14,335 0 0 3 87 14,940 0 0 3 90 15,231 0 0 3 92 BLC4 14,805 0 0 4 90 15,430 0 0 4 93 15,731 0 0 4 95 RCCO 14,464 1 0 3 88 15,074 1 0 3 91 15,368 1 0 3 93 LCCO 14,464 1 0 3 88 15,074 1 0 3 91 15,368 1 0 3 93 AFR 21,031 2 0 3 127 21,918 2 0 3 133 22,345 2 0 3 135 Lumen Output 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 7 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA) Distribution Type 30K 40K 50K (3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P7 184W 40 1400 T1S 22,741 2 0 3 123 23,700 2 0 3 129 24,162 3 0 3 131 T2M 21,066 3 0 4 114 21,955 3 0 4 119 22,383 3 0 4 121 T3M 21,311 3 0 5 116 22,210 3 0 5 120 22,642 3 0 5 123 T3LG 19,036 2 0 2 103 19,839 2 0 3 108 20,226 2 0 3 110 T4M 21,628 3 0 5 117 22,541 3 0 5 122 22,980 3 0 5 125 T4LG 19,671 2 0 2 107 20,501 2 0 3 111 20,900 2 0 3 113 TFTM 21,778 3 0 5 118 22,697 3 0 5 123 23,139 3 0 5 125 T5M 22,252 5 0 3 121 23,191 5 0 3 126 23,643 5 0 3 128 T5W 22,613 5 0 3 123 23,567 5 0 4 128 24,027 5 0 4 130 T5LG 22,317 4 0 2 121 23,258 4 0 2 126 23,712 4 0 2 129 BLC3 15,501 0 0 3 84 16,155 0 0 4 88 16,470 0 0 4 89 BLC4 16,010 0 0 4 87 16,685 0 0 4 90 17,010 0 0 4 92 RCCO 15,641 1 0 3 85 16,301 1 0 3 89 16,619 1 0 3 90 LCCO 15,641 1 0 3 85 16,301 1 0 3 89 16,619 1 0 3 90 AFR 22,741 2 0 3 123 23,700 2 0 3 129 24,162 3 0 3 131 P8 216W 60 1100 T1S 28,701 3 0 3 133 29,912 3 0 4 139 30,495 3 0 4 141 T2M 26,587 3 0 5 123 27,709 3 0 5 128 28,249 3 0 5 131 T3M 26,895 3 0 5 125 28,030 3 0 5 130 28,576 3 0 5 132 T3LG 24,025 3 0 3 111 25,038 3 0 3 116 25,526 3 0 3 118 T4M 27,296 3 0 5 127 28,448 3 0 5 132 29,002 3 0 5 134 T4LG 24,826 3 0 3 115 25,873 3 0 3 120 26,378 3 0 3 122 TFTM 27,485 3 0 5 127 28,645 3 0 5 133 29,203 3 0 5 135 T5M 28,084 5 0 4 130 29,269 5 0 4 136 29,839 5 0 4 138 T5W 28,539 5 0 4 132 29,743 5 0 4 138 30,323 5 0 4 141 T5LG 28,165 4 0 2 131 29,354 4 0 2 136 29,926 4 0 2 139 BLC3 19,563 0 0 4 91 20,388 0 0 4 94 20,786 0 0 4 96 BLC4 20,205 0 0 5 94 21,057 0 0 5 98 21,468 0 0 5 99 RCCO 19,740 1 0 4 91 20,572 1 0 4 95 20,973 1 0 4 97 LCCO 19,740 1 0 4 91 20,572 1 0 4 95 20,973 1 0 4 97 AFR 28,701 3 0 3 133 29,912 3 0 4 139 30,495 3 0 4 141 P9 277W 60 1400 T1S 34,819 3 0 4 126 36,288 3 0 4 131 36,996 3 0 4 134 T2M 32,255 3 0 5 116 33,616 3 0 5 121 34,271 3 0 5 124 T3M 32,629 3 0 5 118 34,006 3 0 5 123 34,668 3 0 5 125 T3LG 29,146 3 0 3 105 30,376 3 0 4 110 30,968 3 0 4 112 T4M 33,116 3 0 5 120 34,513 3 0 5 125 35,185 3 0 5 127 T4LG 30,119 3 0 3 109 31,389 3 0 4 113 32,001 3 0 4 116 TFTM 33,345 3 0 5 120 34,751 3 0 5 125 35,429 3 0 5 128 T5M 34,071 5 0 4 123 35,509 5 0 4 128 36,201 5 0 4 131 T5W 34,624 5 0 4 125 36,084 5 0 4 130 36,788 5 0 4 133 T5LG 34,170 5 0 3 123 35,612 5 0 3 129 36,306 5 0 3 131 BLC3 23,734 0 0 4 86 24,735 0 0 4 89 25,217 0 0 4 91 BLC4 24,513 0 0 5 88 25,547 0 0 5 92 26,045 0 0 5 94 RCCO 23,948 1 0 4 86 24,958 1 0 4 90 25,445 1 0 4 92 LCCO 23,948 1 0 4 86 24,958 1 0 4 90 25,445 1 0 4 92 AFR 34,819 3 0 4 126 36,288 3 0 4 131 36,996 3 0 4 134 Lumen Output 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 8 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Rotated Optics Performance Package System Watts LED Count Drive Current (mA) Distribution Type 30K 40K 50K (3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P10 101W 60 530 T1S 15,164 3 0 3 150 15,803 3 0 3 156 16,112 3 0 3 159 T2M 14,047 4 0 4 139 14,640 4 0 4 145 14,925 4 0 4 147 T3M 14,208 4 0 4 140 14,807 4 0 4 146 15,096 4 0 4 149 T3LG 12,693 3 0 3 125 13,229 3 0 3 131 13,487 3 0 3 133 T4M 14,420 4 0 4 142 15,028 4 0 4 148 15,321 4 0 4 151 T4LG 13,115 3 0 3 129 13,668 3 0 3 135 13,934 3 0 3 138 TFTM 14,522 4 0 4 143 15,134 4 0 4 149 15,429 4 0 4 152 T5M 14,836 4 0 2 146 15,462 4 0 2 153 15,763 4 0 2 156 T5W 15,076 4 0 3 149 15,712 5 0 3 155 16,019 5 0 3 158 T5LG 14,879 3 0 2 147 15,507 3 0 2 153 15,809 3 0 2 156 BLC3 10,335 3 0 3 102 10,771 4 0 4 106 10,981 4 0 4 108 BLC4 10,674 4 0 4 105 11,124 4 0 4 110 11,341 4 0 4 112 RCCO 10,429 1 0 2 103 10,869 1 0 2 107 11,080 1 0 2 109 LCCO 10,429 1 0 2 103 10,869 1 0 2 107 11,080 1 0 2 109 AFR 15,164 3 0 3 150 15,803 3 0 3 156 16,112 3 0 3 159 P11 135W 60 700 T1S 19,437 4 0 4 144 20,257 4 0 4 150 20,651 4 0 4 153 T2M 18,005 4 0 4 133 18,765 4 0 4 139 19,131 4 0 4 142 T3M 18,211 4 0 4 135 18,980 4 0 4 141 19,350 4 0 4 143 T3LG 16,270 3 0 3 121 16,957 3 0 3 126 17,287 4 0 4 128 T4M 18,483 4 0 4 137 19,263 5 0 5 143 19,638 5 0 5 146 T4LG 16,810 3 0 3 125 17,519 3 0 3 130 17,861 3 0 3 132 TFTM 18,614 4 0 4 138 19,399 4 0 4 144 19,777 5 0 5 147 T5M 19,017 5 0 3 141 19,819 5 0 3 147 20,205 5 0 3 150 T5W 19,325 5 0 3 143 20,140 5 0 3 149 20,533 5 0 3 152 T5LG 19,072 4 0 2 141 19,876 4 0 2 147 20,264 4 0 2 150 BLC3 13,247 4 0 4 98 13,806 4 0 4 102 14,075 4 0 4 104 BLC4 13,682 4 0 4 101 14,259 4 0 4 106 14,537 4 0 4 108 RCCO 13,367 1 0 3 99 13,931 1 0 3 103 14,203 1 0 3 105 LCCO 13,367 1 0 3 99 13,931 1 0 3 103 14,203 1 0 3 105 AFR 19,437 4 0 4 144 20,257 4 0 4 150 20,651 4 0 4 153 P12 206W 60 1050 T1S 27,457 4 0 4 133 28,616 4 0 4 139 29,174 4 0 4 142 T2M 25,436 5 0 5 124 26,509 5 0 5 129 27,025 5 0 5 131 T3M 25,727 5 0 5 125 26,812 5 0 5 130 27,335 5 0 5 133 T3LG 22,984 4 0 4 112 23,954 4 0 4 116 24,421 4 0 4 119 T4M 26,110 5 0 5 127 27,212 5 0 5 132 27,742 5 0 5 135 T4LG 23,747 4 0 4 115 24,749 4 0 4 120 25,231 4 0 4 123 TFTM 26,295 5 0 5 128 27,404 5 0 5 133 27,938 5 0 5 136 T5M 26,864 5 0 4 130 27,997 5 0 4 136 28,543 5 0 4 139 T5W 27,299 5 0 4 133 28,451 5 0 4 138 29,006 5 0 4 141 T5LG 26,942 4 0 2 131 28,078 4 0 2 136 28,626 4 0 2 139 BLC3 18,714 4 0 4 91 19,504 4 0 4 95 19,884 4 0 4 97 BLC4 19,327 5 0 5 94 20,143 5 0 5 98 20,535 5 0 5 100 RCCO 18,883 1 0 4 92 19,680 1 0 4 96 20,064 1 0 4 97 LCCO 18,883 1 0 4 92 19,680 1 0 4 96 20,064 1 0 4 97 AFR 27,457 4 0 4 133 28,616 4 0 4 139 29,174 4 0 4 142 P13 276W 60 1400 T1S 34,436 5 0 5 125 35,889 5 0 5 130 36,588 5 0 5 133 T2M 31,900 5 0 5 116 33,246 5 0 5 121 33,894 5 0 5 123 T3M 32,265 5 0 5 117 33,626 5 0 5 122 34,282 5 0 5 124 T3LG 28,826 4 0 4 105 30,042 4 0 4 109 30,628 4 0 4 111 T4M 32,746 5 0 5 119 34,128 5 0 5 124 34,793 5 0 5 126 T4LG 29,782 4 0 4 108 31,039 4 0 4 113 31,644 5 0 4 115 TFTM 32,978 5 0 5 120 34,369 5 0 5 125 35,039 5 0 5 127 T5M 33,692 5 0 4 122 35,113 5 0 4 127 35,797 5 0 4 130 T5W 34,238 5 0 4 124 35,682 5 0 4 129 36,378 5 0 4 132 T5LG 33,789 5 0 3 122 35,215 5 0 3 128 35,901 5 0 3 130 BLC3 23,471 5 0 5 85 24,461 5 0 5 89 24,937 5 0 5 90 BLC4 24,240 5 0 5 88 25,262 5 0 5 92 25,755 5 0 5 93 RCCO 23,683 1 0 4 86 24,682 1 0 4 89 25,163 1 0 4 91 LCCO 23,683 1 0 4 86 24,682 1 0 4 89 25,163 1 0 4 91 AFR 34,436 5 0 5 125 35,889 5 0 5 130 36,588 5 0 5 133 Lumen Output 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 9 of 10 COMMERCIAL OUTDOOR 2.73" 34.23" 14.26" 8.21" 2.73" 34.53" 14.26" 8.90" 2.73" 38.71" 14.26" 7.88" Dimensions DSX1 with RPA, RPA5, SPA5, SPA8N mount Weight: 36 lbs DSX1 with WBA mount Weight: 38 lbs DSX1 with MA mount Weight: 39 lbs 2.41" 3.16" SPA (STANDARD ARM) 2.41" 3.16" RPA 2.41" 3.16" SPA8N 4.25" RPA5 4.25" SPA5 1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2025 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 08/28/25 Page 10 of 10 COMMERCIAL OUTDOOR nLight Control - Sensor Coverage and Settings nLight Sensor Coverage Pattern NLTAIR2 PIRHN Top Side FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 1 reflects the embedded high performance LED technology. It is ideal for many commercial and municipal applications, such as parking lots, plazas, campuses, and streetscapes. CONSTRUCTION Single-piece die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. Modular design allows for ease of maintenance and future light engine upgrades. The LED drivers are mounted in direct contact with the casting to promote low operating temperature and long life. Housing driver compartment is completely sealed against moisture and environmental contaminants (IP66). Vibration rated per ANSI C136.31 for 3G for SPA and MA. 1.5G for mountings RPA, RPA5, SPA5 and SPA8N. Low EPA (0.69 ft2) for optimized pole wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weather- ing. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peel- ing. Available in both textured and non-textured finishes. Coastal Construction (CCE) Optional corrosion resistant construction is engineered with added corrosion protection in materials and/or pre-treatment of base material under super durable paint. Provides additional corrosion protection for applications near coastal areas. Finish is salt spray tested to over 5,000 hours per ASTM B117 with scribe rating of 10. Additional lead-times may apply. OPTICS Precision-molded proprietary silicone lenses are engineered for superior area lighting distribution, uniformity, and pole spacing. Light engines are available in standard 3000 K, 4000 K and 5000 K (70 CRI) configurations. 80CRI configura- tions are also available. The D-Series Size 1 has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine configurations consist of high-efficacy LEDs mounted to metal- core circuit boards to maximize heat dissipation and promote long life (up to L81/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a power factor >90%, THD <20%, and an expected life of 100,000 hours with <1% failure rate. Easily serviceable 10kV surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). STANDARD CONTROLS The DSX1 LED area luminaire has a number of control options. DSX Size 1, comes standard with 0-10V dimming drivers. Dusk to dawn controls can be utilized via optional NEMA twist-lock photocell receptacles. Integrated motion sensor with on-board photocells feature field-adjustable programing and are suitable for mounting heights up to 40 feet. Control option BL features a bi-level device that allows a second control circuit to switch all light engines to either 30% or 50% light output. nLIGHT AIR CONTROLS The DSX1 LED area luminaire is also available with nLight® AIR for the ultimate in wireless control. This powerful controls platform provides out-of-the-box basic motion sensing and photocontrol functionality and is suitable for mounting heights up to 40 feet. Once commissioned using a smartphone and the easy-to- use CLAIRITY app, nLight AIR equipped luminaries can be grouped, resulting in motion sensor and photocell group response without the need for additional equipment. Scheduled dimming with motion sensor over-ride can be achieved when used with the nLight Eclypse. Additional information about nLight Air can be found here. INSTALLATION Integral mounting arm allows for fast mounting using Lithonia standard #8 drill- ing and accommodates pole drilling's from 2.41 to 3.12" on center. The standard “SPA” option for square poles and the “RPA” option for round poles use the #8 drilling. For #5 pole drillings, use SPA5 or RPA5. Additional mountings are available including a wall bracket (WBA) and mast arm (MA) option that allows luminaire attachment to a 2 3/8” horizontal mast arm. LISTINGS UL listed to meet U.S. and Canadian standards. UL Listed for wet locations. Light engines are IP66 rated; luminaire is IP66 rated. Rated for -40°C minimum ambient. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/ QPL to confirm which versions are qualified. International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 3000K color temperature only. GOVERNMENT PROCUREMENT BAA – Buy America(n) Act: Product with the BAA option qualifies as a domestic end product under the Buy American Act as implemented in the FAR and DFARS. Product with the BAA option also qualifies as manufactured in the United States under DOT Buy America regulations. BABA – Build America Buy America: Product with the BAA option also qualifies as produced in the United States under the definitions of the Build America, Buy America Act. Please refer to www.acuitybrands.com/buy-american for additional information. WARRANTY 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. LDN6 STATIC WHITE 6" Open and Wallwash LED Non-IC New Construction Downlight DOWNLIGHTING LDN6 Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE — Typical applications include corridors, lobbies, conference rooms and private offices. CONSTRUCTION — Galvanized steel mounting/plaster frame; galvanized steel junction box with bottom-hinged access covers and spring latches. Reflectors are retained by torsion springs. Vertically adjustable mounting brackets with commercial bar hangers provide 3-3/4" total adjustment. Two combination ½"-3/4" and four ½" knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out). No. 12 AWG conductors, rated for 90°C. Accommodates 12"-24" joist spacing. Passive cooling thermal management for 25°C standard; high ambient (40°C) option available. Light engine and drivers are accessible from above or below ceiling. Max ceiling thickness 1-1/2". OPTICS — LEDs are binned to a 3-step MacAdam Ellipse; 80 CRI minimum. 90 CRI optional. LED light source concealed with diffusing optical lens. General illumination lighting with 1.0 S/MH and 55° cutoff to source and source image. Self-flanged anodized reflectors in specular, semi-specular, or matte diffuse finishes. Also available in white and black painted reflectors. Controls (Optional) — • Luminaire can be equipped with interface for nLight wired, allowing it to communicate over an nLight network. Couple with nLight-enabled sensors, power packs, or WallPods using CAT-5 cabling to create an nLight Control Zone. Link Control Zone to a Gateway directly or via a Bridge for remote status monitoring and control using SensorView software. • Luminaire can be equipped with interface for nLight Air, allowing it to communicate over the wireless nLight control platform. Can be paired to other luminaires and wall switches through CLAIRITY+, a mobile app, which allows individual fixture control. UGR — UGR is zero for fixtures aimed at nadir with a cut-off equal to or less than 60deg, per CIE 117-1996 Discomfort Glare in Interior Lighting. ELECTRICAL — Multi-volt (120-277V, 50/60Hz) 0-10V dimming drivers mounted to junction box, 10% or 1% minimum dimming level available. 0-10V dimming fixture requires two (2) additional low-voltage wires to be pulled. LUMEN MAINTENANCE — 70% lumen maintenance at 60,000 hours. L70/60,000 hours LISTINGS — Certified to US and Canadian safety standards. Wet location standard (covered ceiling). IP55 rated. Drivers are RoHS compliant GOVERNMENT PROCUREMENT — BAA – Product with the BAA option qualifies as a domestic end product under the Buy American Act as implemented in the FAR and DFARS. Product with the BAA option also qualifies as manufactured in the United States under DOT Buy America regulations. BABA – Build America Buy America: Product with the BAA option also qualifies as produced in the United States under the definitions of the Build America, Buy America Act. Please refer to www.acuitybrands.com/buy-american for additional information. WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Aperture: Ø 6-1/4" [15.9] Ceiling Cutout: Ø 7-1/8" [18.1] Self-flanged Overlap Trim: Ø 7-1/2" [19.1] 6 7/16 [16.3]12 5/8 [32.1] 11 3/4 [29.9] LDN6 500-3000 Lumens 5 11/16 [14.4] LDN6 3500K AR LSS 80CRI Nominal Lumens Lumens Wattage Lm/W 500 527.9 5.8 90.5 750 758.1 8.9 85.1 1000 950.1 10.4 91.0 1500 1514 17. 5 86.4 2000 2006 22.5 89.1 2500 2504 28.3 88.6 3000 3021 34.8 86.9 4000 4008 44.3 90.6 5000 4975 57.7 86.3 PERFORMANCE DATA DIMENSIONS See page 4 for other fixture dimensions Notes • Tested in accordance with IESNA LM-79-08. • Tested to current IES and NEMA standards under stabilized laboratory conditions. • CRI: 80 typical. Polar Candela Distribution 1,600 1,333 1,067 800 533 267 0.00 267 533 800 1,067 1,333 1,600 VA: 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140° 150° 160° 170° 180° - 0° H - 90° H Polar Candela Distribution 1,500 1,250 1,000 750 500 250 0.00 250 500 750 1,000 1,250 1,500 VA: 0° 10° 20° 30° 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140° 150° 160° 170° 180° - Max Cd: 135° H - 0° H - 90° H Open Wallwash battery pack Open Trim Wallwash Trim DISTRIBUTIONS LDN6 500-3000 Lumens LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 ORDERING INFORMATION Example: LDN6 35/15 LO6 AR LSS MVOLT EZ10Lead times will vary depending on options selected. Consult with your sales representative. LDN6 Series Color temperature Lumens ‡ Trim Style Trim Color Trim Finish Flange Color ‡ Voltage LDN6 6" round 27/ 2700K 30/ 3000K 35/ 3500K 40/ 4000K 50/ 5000K 05 500 lumens 07 750 lumens 10 1000 lumens 15 1500 lumens 20 2000 lumens 25 2500 lumens 30 3000 lumens 40 4000 lumens 50 5000 lumens LO6 Downlight LW6 Wallwash AR Clear WR ‡ White BR ‡ Black TCPC ‡ Custom painted trim TRALTBD ‡ RAL painted trim LSS Semi-specular LD Matte diffuse LS Specular TRW White painted flange TRBL Black painted flange FCPC Custom painted flange only FRALTBD RAL painted flange only MVOLT Multi-volt 120 120V 277 277V 347 ‡ 347V Driver Emergency ‡ Control Input ‡ Options GZ10 0-10V driver dims to 10% GZ1 0-10V driver dims to 1% D10 Minimum dimming 10% driver for use with SSAIR D1 Minimum dimming 1% driver for use with SSAIR EZ1 0-10V eldoLED driver with smooth and flicker- free deep dimming performance down to 1% EDAB eldoLED DALI SOLDRIVE dim to dark (blank) No Emergency Needed EL Battery pack (10W constant power), non-T20 compliant, integral test switch ELR Battery pack (10W constant power), non-T20 compliant, remote test switch ELSD Self-diagnostic battery pack (10W constant power), non-T20 compliant, integral test switch ELRSD Self-diagnostic battery pack (10W constant power), non-T20 compliant, remote test switch E10WCP Battery pack (10W constant power), T20 compliant, integral test switch E10WCPR Battery pack (10W constant power), T20 compliant, remote test switch E10WRSTAR Emergency battery pack, 10W with remote test switch and Iota STAR technology (blank) No Control Input Needed SSAIR Wireless standalone embedded control by SensorSwitch NPP16D nLight® network power/relay pack with 0-10V dim - ming for non-eldoLED drivers (GZ10, GZ1). NPP16DER nLight® network power/relay pack with 0-10V dimming for non-eldoLED drivers (GZ10, GZ1). ER controls fixtures on emergency circuit. NPS80EZ nLight® dimming pack controls 0-10V eldoLED drivers (EZ1). NPS80EZER nLight® dimming pack controls 0-10V eldoLED driv - ers (EZ1). ER controls fixtures on emergency circuit. N80 nLight™ Lumen Compensation NLTAIR2 nLight® Air enabled NLTAIRER2 nLight® AIR Dimming Pack Wireless Controls. Controls fixtures on emergency circuit, not available with battery pack options NLTAIREM2 nLight® AIR Dimming Pack Wireless Controls. UL924 Emergency Operation, via power interrupt detection. Available with battery pack options. HAO ‡ High ambient option (40°C) CP ‡ Chicago Plenum RRL__ RELOC®-ready luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Refer to RRL for complete nomenclature. Available only in RRLA, RRLB, RRLAE, and RRLC12S. BAA Buy America(n) Act and/or Build America Buy America Qualified 90CRI High CRI (90+) SF ‡ Single fuse ‡ Option Value Ordering Restrictions Option value Restriction Lumens Overall height varies based on lumen package; refer to dimensional chart. WR, BR Not available with finishes. 347 Not available with emergency options. SF Must specify voltage 120V or 277V. TRW, TRBL Available with clear (AR) reflector only. EL, ELR, ELSD, ELRSD, E10WCP, E10WCPR 12.5" of plenum depth or top access required for battery pack maintenance. NPP16D, NPP16DER, NPS80EZ, NPS80EZER Specify voltage. ER for use with generator supply EM power. Will require an emergency hot feed and normal hot feed. See UL 924 Sequence of Operation table. N80 Fixture begins at 80% light level. Must be specified with NPS80EZ or NPS80EZ ER. Only available with EZ1 drivers. NLTAIR, NLTAIR2, NLTAIRER2, NLTAIREM2 Not available with CP , NPS80EZ, NPS80EZER, NPP16D, NPP16DER or N80 options. Not recommended for metal ceiling installations. HAO Fixture height is 6.5" for all lumen packages with HAO. CP Must specify voltage for 3000lm and above. 5000lm with marked spacing 24 L x 24 W x 14 H. Not available with emergency battery pack option. JOT Must specify D10 or D1 driver. Not available with nLight options. Not available with CP . Not recommended for metal ceiling installation. Not for use with emergency backup power systems other than battery packs. Reloc® Options Refer to RRL specification sheet on acuitybrands.com for further details. RRLAE Commercial fixtures should disconnect the TSPL before unplugging the RRL so it does not go into discharge mode. RRLC12S RRLC12S option is to be used with the OnePass OCU, OCS, OD, OFC and OD for 0-24V integrated single-circuit or 0-10V low voltage controls applications. Not available with integral dimming sensors. TRALTBD, FRALTBD RALTBD for pricing only. Replace with applicable RAL number and finish when ready to order. See the RAL BROCHURE for available color options. Not available with TCPC or FCPC TCPC, FCPC CPC options for pricing only. Custom color chip needs to be sent in to your Customer Resolution specialist before order can be processed. Click HERE for more details. Not available with TRAL or FRAL E10WRSTAR Not available with wet location, EC1, EC6, QDS, CP , 347V, NPS80EZ ER, NLTAIRER2, NLTAIREM2, ALO3 & ALO4 w/DALI, OR 2000-4500 lumens w/SSAIR. Top access installation or 17.5" plenum clearance required for roomside installation. Not available with integral test switch Accessories: Order as separate catalog number. EAC ISSM 375 Compact interruptible emergency AC power system EAC ISSM 125 Compact interruptible emergency AC power system GRA68 JZ Oversized trim ring with 8" outside diameter SCA6 Sloped Ceiling Adapter. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA6 10D. Design Select options indicated by this color background. Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect. *See ordering tree for details (Maximum order quantity for design select lead times is 112.) LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 Emergency Battery Pack Options - Field Installable Battery Model Number Wattage Runtime (Minutes) Lumen Output* @ 120 Lumens/Watt Other ILB CP07 2H A 7W 120 840 Storm Shelter / 2 Hour Runtime ILB CP10 A 10W 90 1200 ILBLP CP10 HE SD A+ 10W 90 1200 Title 20, Self Diagnostic ILBLP CP15 HE SD A+ 15W 90 1800 Title 20, Self Diagnostic ILB CP20 HE A 20W 90 2400 Title 20 ILB CP20 HE SD A 20W 90 2400 Title 20, Self Diagnostic ILBHI CP10 HE SD A+ 10W 90 1200 347-480V AC Input, Title 20, Self Diagnostic ILBHI CP15 HE SD A+ 15W 90 1800 347-480V AC Input, Title 20, Self Diagnostic All the above are UL Listed products that are certified for field install external/remote to the fixture. *Minimum delivered lumen output to assist in product selection for increased fixture mounting height. The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast. Please contact us at techsupport@iotaengineering.com for any Emergency Battery related questions. Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provided consistent color appearance and out-of-the-box control capability with simple commissioning when used with Acuity Brands controls products. All configurations of this luminaire are calibrated and tested meet the Acuity Brands' specification for chromatic consistency - including color rendering, color fidelity and color temperature tolerance around standard CIE chromaticity coordinates. To learn more about A+, visit www.acuitybrands.com/aplus. COMPATIBLE 0-10V WALL-MOUNT DIMMERS MANUFACTURER PART NO. POWER BOOSTER AVAILABLE Lutron® Diva® DVTV Diva® DVSCTV Nova T® NTFTV Nova® NFTV Leviton® AWSMT-7DW CN100 AWSMG-7DW PE300 AMRMG-7DW Leviton Centura Fluorescent Control System IllumaTech® IP7 Series Synergy® ISD BC RDMFCSLD LPCS Digital Equinox (DEQ BC) Douglas Lighting Controls W P C-57 21 Entertainment Technology Tap Glide TG600FAM120 (120V) Tap Glide Heatsink TGH1500FAM120 (120V) Oasis 0A2000FAMU Honeywell EL7315A1019 EL7305A1010 (optional)EL7315A1009 HUNT Dimming Preset slide: PS-010-IV and PS-010-WH Preset slide: PS-010-3W-IV and PS-010-3W-WH Preset slide, controls FD-010: PS-IFC-010-IV and PS-IFC- 010-WH-120/277V Preset slide, controls FD-010: PS-IFC-010-3W-IV and PS-IFC-010-3W-WH-120/277V Remote mounted unit: FD-010 Lehigh Electronic Products Solitaire PBX PDM Electrical Products W P C-57 21 Starfield Controls TR61 with DALI interface port RT03 DALInet Router WattStopper® LS-4 used with LCD-101 and LCD-103 LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 LDN6 35/10 LO6AR, input watts: 10.44, delivered lumens: 987 .10, LM/W = 94.54, spacing criterion at 0= 1.02, test no. ISF 30716P262. LDN6 35/15 LO6AR, input watts: 17 .52, delivered lumens: 1572.9, LM/W = 89.77 , spacing criterion at 0= 1.02, test no. ISF 30716P265. LDN6 35/30 LO6AR, input watts: 34.75, delivered lumens: 3138.5, LM/W = 90.31, spacing criterion at 0= 1.02, test no. ISF 30716P274. PHOTOMETRY Distribution Curve Distribution Data Output Data Illuminance Data at 30 " Above Floor for a Single Luminaire PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P262 Lithonia Lighting LDN6 35/10 LO6AR LS 6IN LDN, 3500K, 1000LM, CLEAR, SPECULAR REFLECTOR, CRI80 987.0469 LED LDN6 Round Series f10c02be-762d-40f0-9a15-d770f5aadb94 6 RECESSED DOWNLIGHT 987.1 10.44 -0.52, -0.52, 0 0° 20° 40° 60° 80° 200 400 600 800 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 876 905 971 720 330 110 1 1 0 0 0 89 269 322 214 87 4 1 0 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 680.7 895.0 986.0 987.0 0.0 0.0 0.0 0.0 987.0 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 29.0 15.6 9.7 6.6 4.8 5.7 7.7 9.8 11.8 13.9 14.5 7.8 4.9 3.3 2.4 9.6 13.1 16.6 20.1 23.6 2.9 1.6 1.0 0.7 0.5 Spacing to Mounting Height: 1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P265 Lithonia Lighting LDN6 35/15 LO6AR LS 6IN LDN, 3500K, 1500LM, CLEAR, SPECULAR REFLECTOR, CRI80 1572.875 LED LDN6 Round Series 353e6a9b-84c5-4dbd-9a8d-3e8e112b9264 6 RECESSED DOWNLIGHT 1572.9 17.52 -0.52, -0.52, 0 0° 20° 40° 60° 80° 600 1200 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 1396 1442 1547 1147 526 176 2 1 1 0 0 142 429 514 342 139 6 1 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 1084.6 1426.2 1571.3 1572.9 0.0 0.0 0.0 0.0 1572.9 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 46.2 24.8 15.5 10.6 7.7 5.7 7.7 9.8 11.8 13.9 23.1 12.4 7.7 5.3 3.8 9.6 13.1 16.6 20.1 23.6 4.6 2.5 1.5 1.1 0.8 Spacing to Mounting Height: 1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P274 Lithonia Lighting LDN6 35/30 LO6AR LS 6IN LDN, 3500K, 3000LM, CLEAR, SPECULAR REFLECTOR, CRI80 3138.479 LED LDN6 Round Series d5b00a16-a91a-46b1-8fc1-15e68906b538 6 RECESSED DOWNLIGHT 3138.5 34.75 -0.52, -0.52, 0 0° 20° 40° 60° 80° 1200 2400 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 2786 2877 3087 2289 1049 350 5 2 1 0 0 284 855 1025 682 277 12 2 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 2164.3 2845.9 3135.3 3138.5 0.0 0.0 0.0 0.0 3138.5 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 92.1 49.5 30.9 21.1 15.3 5.7 7.7 9.8 11.8 13.9 46.1 24.8 15.4 10.5 7.6 9.6 13.1 16.6 20.1 23.6 9.2 5.0 3.1 2.1 1.5 Spacing to Mounting Height: 1.0 LUMEN OUTPUT MULTIPLIERS - FINISH Clear (AR) White (WR) Black (BR) Specular (LS) 1.0 N/A N/A Semi-specular (LSS) 0.950 N/A N/A Matte diffuse (LD) 0.85 N/A N/A Painted N/A 0.87 0.73 LUMEN OUTPUT MULTIPLIERS - CCT 2700K 3000K 3500K 4000K 5000K 80CRI 0.950 0.966 1.000 1.025 1.101 HOW TO ESTIMATE DELIVERED LUMENS IN EMERGENCY MODE Use the formula below to estimate the delivered lumens in emergency mode Delivered Lumens = 1.25 x P x LPW P = Ouput power of emergency driver. P = 10W LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. The LPW rating is also available at Designlight Consortium. LUMEN OUTPUT MULTIPLIERS - CRI 80 1.0 90 0.874 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P262 Lithonia Lighting LDN6 35/10 LO6AR LS 6IN LDN, 3500K, 1000LM, CLEAR, SPECULAR REFLECTOR, CRI80 987.0469 LED LDN6 Round Series f10c02be-762d-40f0-9a15-d770f5aadb94 6 RECESSED DOWNLIGHT 987.1 10.44 -0.52, -0.52, 0 0° 20° 40° 60° 80° 200 400 600 800 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 876 905 971 720 330 110 1 1 0 0 0 89 269 322 214 87 4 1 0 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 680.7 895.0 986.0 987.0 0.0 0.0 0.0 0.0 987.0 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 29.0 15.6 9.7 6.6 4.8 5.7 7.7 9.8 11.8 13.9 14.5 7.8 4.9 3.3 2.4 9.6 13.1 16.6 20.1 23.6 2.9 1.6 1.0 0.7 0.5 Spacing to Mounting Height: 1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P265 Lithonia Lighting LDN6 35/15 LO6AR LS 6IN LDN, 3500K, 1500LM, CLEAR, SPECULAR REFLECTOR, CRI80 1572.875 LED LDN6 Round Series 353e6a9b-84c5-4dbd-9a8d-3e8e112b9264 6 RECESSED DOWNLIGHT 1572.9 17.52 -0.52, -0.52, 0 0° 20° 40° 60° 80° 600 1200 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 1396 1442 1547 1147 526 176 2 1 1 0 0 142 429 514 342 139 6 1 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 1084.6 1426.2 1571.3 1572.9 0.0 0.0 0.0 0.0 1572.9 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 46.2 24.8 15.5 10.6 7.7 5.7 7.7 9.8 11.8 13.9 23.1 12.4 7.7 5.3 3.8 9.6 13.1 16.6 20.1 23.6 4.6 2.5 1.5 1.1 0.8 Spacing to Mounting Height: 1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P274 Lithonia Lighting LDN6 35/30 LO6AR LS 6IN LDN, 3500K, 3000LM, CLEAR, SPECULAR REFLECTOR, CRI80 3138.479 LED LDN6 Round Series d5b00a16-a91a-46b1-8fc1-15e68906b538 6 RECESSED DOWNLIGHT 3138.5 34.75 -0.52, -0.52, 0 0° 20° 40° 60° 80° 1200 2400 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 2786 2877 3087 2289 1049 350 5 2 1 0 0 284 855 1025 682 277 12 2 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 2164.3 2845.9 3135.3 3138.5 0.0 0.0 0.0 0.0 3138.5 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RCR 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 92.1 49.5 30.9 21.1 15.3 5.7 7.7 9.8 11.8 13.9 46.1 24.8 15.4 10.5 7.6 9.6 13.1 16.6 20.1 23.6 9.2 5.0 3.1 2.1 1.5 Spacing to Mounting Height: 1.0 Notes • Tested in accordance with IESNA LM-79-08. • Tested to current IES and NEMA standards under stabilized laboratory conditions. • CRI: 80 typical. LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 * All dimensions are inches (centimeters) unless otherwise noted. 11 3 16 (28.4) 97 16 (24.0) 11 3 16 (28.4) 97 16 (24.0) 4 (10.2) 39 16 (9.0) 6 (15.2) 59 16 (14.1) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) LDN6 500 - 1500 LUMENS LDN6 2000 - 3000 LUMENS LDN6 4000 - 5000 LUMENS 97 16 (24.0) 11 3 16 (28.4) 6 (15.2) 59 16 (14.1) Marked Spacing: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) LDN6 CP LDN6 EL 215 16 (54.1) 1613 16 (42.7) 91 16 (23.0) 14 9 16 (11.6) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) 191 8 (48.5) 20 5 16 (51.6) 6 (15.2) 59 16 (14.1) Marked Spacing above 3000 Lumens: 24 x 24 x 10 Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) Aperture: Ø 6-1/4" [15.9] Ceiling Cutout: Ø 7-1/8" [18.1] Self-flanged Overlap Trim: Ø 7-1/2" [19.1] 6 7/16 [16.3]12 5/8 [32.1] 11 3/4 [29.9] LDN6 500-3000 Lumens 5 11/16 [14.4] Aperture: Ø 6-1/4" [15.9] Ceiling Cutout: Ø 7-1/8" [18.1] Self-flanged Overlap Trim: Ø 7-1/2" [19.1] 6 7/16 [16.3]12 5/8 [32.1] 11 3/4 [29.9] LDN6 4000-5000 Lumens 5 11/16 [14.4] Marked Spacing: 24" x 24" x 10" Aperture: Ø 6-1/4" [15.9] Ceiling Cutout: Ø 7-1/8" [18.1] Self-flanged Overlap Trim: Ø 7-1/2" [19.1] 6 7/16 [16.3]12 5/8 [32.1] LDN6 EL 5 11/16 [14.4] Marked Spacing above 3000lm: 24" x 24" x 10" 19 [48.3] 15 1/4 [38.8] LDN6 500-3000 Lumens LDN6 4000-5000 Lumens LDN6 CP LDN6 EL LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 Performance Y ou Can Count On SensorSwitch™ offers standalone wired and wireless lighting controls solutions designed for room-based applications. Our products offer reliable performance and ease of installation. Sensorswitch.com Wireless Embedded Controls 1. Install the luminaires with embedded controls 2. Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds. 3. Once paired, each fixture will individually dim down to 10% brightness. All products will be fully functional. SensorSwitch WSXA SSA LDN6 DOWNLIGHTING: 1 Acuity Way, Decatur, GA 30035 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/04/26 LDN6 UL924 Sequence of Operation The below information applies to all nLight AIR devices with an EM option. • EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. • Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. • Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing. Single Lighting Controls Platform for Indoor & Outdoor Spaces nLight® is your networked lighting controls platform, for indoor and outdoor applications, providing wired or wireless options. Scaling from room to campus-wide applications, it is the one platform that grows with your business today and tomorrow; to seamlessly address energy cost optimization, building code compliance, improved occupant comfort, and much more. nLight also interfaces with DALI®, BACnet®, DMX and additional third-party devices. nLightcontrols.com Wired Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight Wired wall switch 3. Connect the luminaires using standard CAT-5e cables and the controls devices will automatically discover each other and work (plug and play) CAT -5e nLight nPODMA DX NH NH NH Wireless Embedded Controls 1. Install the luminaires with embedded controls 2. Install the nLight AIR battery-powered wall switch 3. Use CLAIRITY+ mobile app to pair the fixtures with the wall switch and if desired, customize the sensor settings nLight rPODBA 2P DX NH NH NH Mobile Device Introduction The WDGE LED family is designed to meet specifier’s every wall- mounted lighting need in a widely accepted shape that blends with any architecture. The clean rectilinear design comes in four sizes with lumen packages ranging from 1,200 to 25,000 lumens, providing a true site-wide solution. Embedded with nLight® AIR wireless controls, the WDGE family provides additional energy savings and code compliance. WDGE2 with industry leading precision refractive optics provides great uniform distribution and optical control. When combined with multiple integrated emergency battery backup options, including an 18W cold temperature option, the WDGE2 becomes the ideal wall-mounted lighting solution for pedestrian scale applications in any environment. 1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2019-2026 Acuity Brands Lighting, Inc. All rights reserved. WDGE2 LED Rev. 07/06/26 COMMERCIAL OUTDOOR WDGE2 LED Architectural Wall Sconce Precision Refractive Optic Catalog Number Notes Type Depth (D1): 7" Depth (D2): 1.5" Height: 9" Width: 11.5" Weight: (without options) 13.5 lbs Hit the Tab key or mouse over the page to see all interactive elements. Specifications Series Package Color Temperature CRI Distribution Voltage Mounting WDGE2 LED P0 P1 1 P2 1 P3 1 P4 1 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K AMB2 Amber 70CRI3 80CRI LW 2 Limited Wavelength T1S Type I Short T2M Type II Medium T3M Type III Medium T4M Type IV Medium TFTM Forward Throw Medium MVOLT 347 4 480 4 Shipped included SRM Surface mounting bracket ICW Indirect Canopy/Ceiling Washer bracket (dry/ damp locations only)5 Shipped separately AWS 3/8inch Architectural wall spacer6 PBBW Surface-mounted back box (top, left, right conduit entry). Use when there is no junction box available6 Options Finish E10WH Emergency battery backup, Certified in CA Title 20 MAEDBS (10W , 5°C min) E20WC Emergency battery backup, Certified in CA Title 20 MAEDBS (18W , -20°C min) PE Photocell, Button Type 7 DMG 0-10V dimming wires pulled outside fixture (for use with an external control, ordered separately)8 BCE Bottom conduit entry for back box (PBBW). Total of 4 entry points. CCE Coastal Construction6 Standalone Sensors/Controls PIR Bi-level (100/35%) motion sensor for 8-15' mounting heights. Intended for use on switched circuits with external dusk to dawn switching. PIRH Bi-level (100/35%) motion sensor for 15-30' mounting heights. Intended for use on switched circuits with external dusk to dawn switching PIR1FC3V Bi-level (100/35%) motion sensor for 8-15' mounting heights with photocell pre-programmed for dusk to dawn operation. PIRH1FC3V Bi-level (100/35%) motion sensor for 15-30' mounting heights with photocell pre-programmed for dusk to dawn operation. Networked Sensors/Controls NLTAIR2 PIR Embedded wireless controls by nLight with Passive Infrared Occ sensor and on/off photocell for 8-15' mounting heights. NLTAIR2 PIRH Embedded wireless controls by nLight with Passive Infrared Occ sensor and on/off photocell for 15-30' mounting heights. NLTAIREM2 PIR Embedded wireless controls by nLight with UL924 listed emegency operation, Passive Infrared Occ sensor and on/off photocell for 8-15' mounting heights NLTAIREM2 PIRH Embedded wireless controls by nLight with UL924 listed emegency operation, Passive Infrared Occ sensor and on/off photocell for 15-30' mounting heights. See page 4 for out of box functionality DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DSSXD Sandstone DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white DSSTXD Textured sandstone Ordering Information EXAMPLE: WDGE2 LED P3 40K 80CRI T3M MVOLT SRM DDBXD Luminaire Optics Standard EM, 0°C Cold EM, -20°C Sensor Approximate Lumens (4000K, 80CRI) P0 P1 P2 P3 P4 P5 P6 WDGE1 LED Visual Comfort 4W -- 750 1,200 2,000 -- -- -- -- WDGE2 LED Visual Comfort 10W 18W Standalone / nLight -- 1,200 2,000 3,000 4,500 6,000 -- WDGE2 LED Precision Refractive 10W 18W Standalone / nLight 700 1,200 2,000 3,200 4,200 -- -- WDGE3 LED Precision Refractive 15W 18W Standalone / nLight -- 7,500 8,500 10,000 12,000 -- -- WDGE4 LED Precision Refractive Standalone / nLight -- 12,000 16,000 18,000 20,000 22,000 25,000 WDGE LED Family Overview D1W D2 H Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect. *See ordering tree for details NOTES 1 P1-P4 not available with AMB and LW. 2 AMB and LW always go together. 3 70CRI only available with T3M and T4M. 4 347V and 480V not available with E10WH or E20WC. 5 Not qualified for DLC. Not available with emergency battery backup or sensors/controls. 6 For PBBW and AWS with CCE option, require an RFA. 7 PE not available in 480V or with sensors/controls. 8 DMG option not available with sensors/controls. Accessories Ordered and shipped separately. WDGEAWS DDBXD U WDGE 3/8inch Architectural Wall Spacer (specify finish) WDGE2PBBW DDBXD U WDGE2 surface-mounted back box (specify finish) Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package System Watts Dist. Type 27K (2700K, 80 CRI) 30K (3000K, 80 CRI) 40K (4000K, 80 CRI) 50K (5000K, 80 CRI) Amber (Limited Wavelength) Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G P0 7W T1S 636 92 0 0 0 666 97 0 0 0 699 101 0 0 1 691 100 0 0 1 712 47 0 0 1 T2M 662 96 0 0 0 693 101 0 0 0 728 106 0 0 0 719 104 0 0 0 741 48 0 0 0 T3M 662 96 0 0 0 693 101 0 0 0 728 106 0 0 0 719 104 0 0 0 741 48 0 0 0 T4M 648 94 0 0 0 679 98 0 0 0 712 103 0 0 0 704 102 0 0 0 726 47 0 0 0 TFTM 652 95 0 0 0 683 99 0 0 0 717 104 0 0 0 708 103 0 0 0 730 48 0 0 1 P1 11W T1S 1,105 99 0 0 1 1,157 104 0 0 1 1,215 109 0 0 1 1,200 107 0 0 1 T2M 1,150 103 0 0 1 1,204 108 0 0 1 1,264 113 0 0 1 1,249 112 0 0 1 T3M 1,150 103 0 0 1 1,205 108 0 0 1 1,265 113 0 0 1 1,250 112 0 0 1 T4M 1,126 101 0 0 1 1,179 106 0 0 1 1,238 111 0 0 1 1,223 110 0 0 1 TFTM 1,133 101 0 0 1 1,186 106 0 0 1 1,245 112 0 0 1 1,230 110 0 0 1 P2 19W T1S 1,801 95 1 0 1 1,886 99 1 0 1 1,981 104 1 0 1 1,957 103 1 0 1 T2M 1,875 99 1 0 1 1,963 103 1 0 1 2,061 109 1 0 1 2,037 107 1 0 1 T3M 1,876 99 1 0 1 1,964 103 1 0 1 2,062 109 1 0 1 2,038 107 1 0 1 T4M 1,836 97 1 0 1 1,922 101 1 0 1 2,018 106 1 0 1 1,994 105 1 0 1 TFTM 1,847 97 1 0 1 1,934 102 1 0 1 2,030 107 1 0 1 2,006 106 1 0 1 P3 32W T1S 2,809 87 1 0 1 2,942 92 1 0 1 3,089 96 1 0 1 3,052 95 1 0 1 T2M 2,924 91 1 0 1 3,062 95 1 0 1 3,215 100 1 0 1 3,176 99 1 0 1 T3M 2,925 91 1 0 1 3,063 95 1 0 1 3,216 100 1 0 1 3,177 99 1 0 1 T4M 2,862 89 1 0 1 2,997 93 1 0 1 3,147 98 1 0 1 3,110 97 1 0 1 TFTM 2,880 90 1 0 1 3,015 94 1 0 1 3,166 99 1 0 1 3,128 97 1 0 1 P4 47W T1S 3,729 80 1 0 1 3,904 84 1 0 1 4,099 88 1 0 1 4,051 87 1 0 1 T2M 3,881 83 1 0 1 4,063 87 1 0 1 4,267 91 1 0 1 4,216 90 1 0 1 T3M 3,882 83 1 0 1 4,065 87 1 0 1 4,268 91 1 0 1 4,217 90 1 0 1 T4M 3,799 81 1 0 1 3,978 85 1 0 1 4,177 90 1 0 1 4,127 88 1 0 1 TFTM 3,822 82 1 0 1 4,002 86 1 0 1 4,202 90 1 0 1 4,152 89 1 0 1 Performance Package System Watts Dist. Type 27K (2700K, 70 CRI) 30K (3000K, 70 CRI) 40K (4000K, 70 CRI) 50K (5000K, 70 CRI) Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G P0 7W T3M 737 107 0 0 0 763 111 0 0 0 822 119 0 0 0 832 121 0 0 1 T4M 721 105 0 0 0 746 108 0 0 0 804 117 0 0 1 814 118 0 0 1 P1 11W T3M 1,280 115 0 0 1 1,325 119 0 0 1 1,427 128 1 0 1 1,445 129 1 0 1 T4M 1,253 112 0 0 1 1,297 116 0 0 1 1,397 125 0 0 1 1,415 127 0 0 1 P2 19W T3M 2,087 110 1 0 1 2,160 114 1 0 1 2,327 123 1 0 1 2,357 124 1 0 1 T4M 2,042 108 1 0 1 2,114 111 1 0 1 2,278 120 1 0 1 2,306 121 1 0 1 P3 32W T3M 3,254 101 1 0 1 3,369 105 1 0 1 3,629 113 1 0 1 3,675 114 1 0 1 T4M 3,185 99 1 0 1 3,297 103 1 0 1 3,552 111 1 0 1 3,597 112 1 0 1 P4 47W T3M 4,319 93 1 0 1 4,471 96 1 0 1 4,817 103 1 0 2 4,878 105 1 0 2 T4M 4,227 91 1 0 1 4,376 94 1 0 2 4,714 101 1 0 2 4,774 102 1 0 2 1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2019-2026 Acuity Brands Lighting, Inc. All rights reserved. WDGE2 LED Rev. 07/06/26 COMMERCIAL OUTDOOR Performance Data Lumen Output Option Lumens E10WH 1,358 E20WC 2,230 Lumen Output in Emergency Mode (4000K, 80 CRI, T3M) 1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2019-2026 Acuity Brands Lighting, Inc. All rights reserved. WDGE2 LED Rev. 07/06/26 COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit the Lithonia Lighting WDGE LED homepage. Tested in accordance with IESNA LM-79 and LM-80 standards. Photometric Diagrams The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining the aesthetics of the product. All emergency battery backup configurations include an independent secondary driver with an integral relay to immediately detect loss of normal power and automatically energize the luminaire. The emergency battery will power the luminaire for a minimum duration of 90 minutes (maximum duration of three hours) from the time normal power is lost and maintain a minimum of 60% of the light output at the end of 90minutes. Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety Code Section 7.9 Emergency Egress Options Emergency Battery Backup LEGEND 0.25 fc 0.5 fc 3.0 fc 1.0 fc MH = 10ft Grid = 10ft x 10ft Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.03 10°C 50°F 1.02 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF , use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor 1.0 >0.96 >0.93 >0.87 Performance Package System Watts Current (A) 120Vac 208Vac 240Vac 277Vac 347Vac 480Vac P0 7.0 0.061 0.042 0.04 0.039 -- -- 9.0 -- -- -- -- 0.031 0.021 P1 11.0 0.100 0.064 0.059 0.054 -- -- 14.1 -- -- -- -- 0.046 0.031 P2 19.0 0.168 0.106 0.095 0.083 -- -- 22.8 -- -- -- -- 0.067 0.050 P3 32.0 0.284 0.163 0.144 0.131 -- -- 37.1 -- -- -- -- 0.107 0.079 P4 47.0 0.412 0.234 0.207 0.185 -- -- 53.5 -- -- -- -- 0.153 0.112 Electrical Load "P3 40K 80CRI T1S""P3 40K 80CRI T1S" "P3 40K 80CRI T2M""P3 40K 80CRI T2M" "P3 40K 80CRI T3M""P3 40K 80CRI T3M" "P3 40K 80CRI T4M""P3 40K 80CRI T4M" "P3 40K 80CRI TFTM""P3 40K 80CRI TFTM" 1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2019-2026 Acuity Brands Lighting, Inc. All rights reserved. WDGE2 LED Rev. 07/06/26 COMMERCIAL OUTDOOR Motion/Ambeint sensor (Sensor Switch MSOD) is integrated into the the luminaire. The sensor provides both Motion and Daylight based dimming of the luminaire. For motion detection, the sensor utilizes 100% Digital Passive Infrared (PIR) technology that is tuned for walking size motion while preventing false tripping from the environment. The integrated photocell enables additional energy savings during daytime periods when there is sufficient daylight. Optimize sensor coverage by either selecting PIR or PIRH option. PIR option comes with a sensor lens that is optimized to provide maximum coverage for mounting heights between 8-15ft, while PIRH is optimized for 15-40ft mounting height. Control / Sensor Options Motion/Ambient Sensor (PIR_, PIRH_) nLight® AIR is a wireless lighting controls platform that allows for seamless integration of both indoor and outdoor luminaires. Five-tier security architecture, 900 MHz wireless communication and app (CLAIRITY™ Pro) based configurability combined together make nLight® AIR a secure, reliable and easy to use platform. Networked Control (NLTAIR2) HIGH VIEW 0 ft 15 0 m 4.6 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 30 24 18 12 6 0 ft 6 12 18 24 30 9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2 LOW VIEW 0 ft 9 0 m 2.7 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4 18 15 12 9 6 3 0 ft 3 6 9 12 15 18 5.5 4.6 3.7 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.7 4.6 5.5 PIR PIRH TOP VIEW 20 10 0 ft 10 20 6.1 3 0 m 3 6.1 20 0 ft 20 6.1 0 m 6.1 SIDE VIEW 0 ft 10 20 30 40 0 m 3 6.1 9.1 12.2 TOP VIEW 20 10 0 ft 10 20 6.1 3 0 m 3 6.1 20 0 ft 20 6.1 0 m 6.1 SIDE VIEW 0 ft 10 20 30 40 0 m 3 6.1 9.1 12.2 Option Dim Level High Level (when triggered Photocell Operation Motion Time Delay Ramp-down Time Ramp-up Time PIR or PIRH Motion - 3V (37% of full output) Photocell - 0V (turned off) 10V (100% output) Enabled @ 5fc 5 min 5 min Motion - 3 sec Photocell - 45 sec PIR1FC3V, PIRH1FC3V Motion - 3V (37% of full output) Photocell - 0V (turned off) 10V (100% output) Enabled @ 1fc 5 min 5 min Motion - 3 sec Photocell - 45 sec NLTAIR2 PIR, NLTAIR2 PIRH, NLTAIREM2 PIR, NLTAIREM2 PIRH (out of box) Motion - 3V (37% of full output) Photocell - 0V (turned off) 10V (100% output) Enabled @ 5fc 7.5 min 5 min Motion - 3 sec Photocell - 45 sec • NLTAIREM2 devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. • Using the CLAIRITY+ mobile app, NLTAIREM2 devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. • The non-emergency devices, NLTAIR2 PIR and NLTAIR2 PIRH, with version 3.4 or later firmware can be used for normal power sensing. UL 924 Response – nLight AIR Devices with EM Option 1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2019-2026 Acuity Brands Lighting, Inc. All rights reserved. WDGE2 LED Rev. 07/06/26 COMMERCIAL OUTDOOR FEATURES & SPECIFICATIONS INTENDED USE Common architectural look, with clean rectilinear shape, of the WDGE LED was designed to blend with any type of construction, whether it be tilt-up, frame or brick. Applications include commercial offices, warehouses, hospitals, schools, malls, restaurants, and other commercial buildings. CONSTRUCTION The single-piece die-cast aluminum housing integrates secondary heat sinks to optimize thermal transfer from the internal light engine heat sinks and promote long life. The driver is mounted in direct contact with the casting for a low operating temperature and long life. The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out moisture and dust, providing an IP66 rating for the luminaire. FINISH Exterior painted parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum, sandstone and white. Available in textured and non-textured finishes. COASTAL CONSTRUCTION (CCE) Optional corrosion resistant construction is engineered with added corrosion protection in materials and/or pre-treatment of base material under super durable paint. Provides additional corrosion protection for applications near coastal areas. Finish is salt spray tested to over 5,000 hours per ASTM B117 with scribe rating of 10. Additional lead-times may apply. OPTICS Individually formed acrylic lenses are engineered for superior application efficiency which maximizes the light in the areas where it is most needed. The WDGE LED has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize heat dissipation and promote long life (up to L91/100,000 hours at 25°C). The electronic driver has a power factor of >90%, THD <20%. Luminaire comes with built in 6kV surge protection, which meets a minimum Category C low exposure (per ANSI/IEEE C62.41.2). Fixture ships standard with 0-10v dimmable driver. INSTALLATION A universal mounting plate with integral mounting support arms allows the fixture to hinge down for easy access while making wiring connections. The 3/8” Architectural Wall Spacer (AWS) can be used to create a floating appearance or to accommodate small imperfections in the wall surface. The ICW option can be used to mount the luminaire inverted for indirect lighting in dry and damp locations. Design can withstand up to a 1.5 G vibration load rating per ANSI C136.31. LISTINGS CSA certified to U.S. and Canadian standards. Luminaire is IP66 rated. PIR options are rated for wet location. Rated for -40°C minimum ambient. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 2700K and 3000K color temperature only and SRM mounting only. GOVERNMENT PROCUREMENT BAA – Buy American Act: This product is available in a version that qualifies as a domestic end product under the Buy American Act as implemented in the FAR and DFARS. BABA – Build America Buy America: This product is available in a version that qualifies as produced in the United States under the definitions of the Build America, Buy America Act, as implemented by 2 C.F .R. Part 184 and other agency implementing regulations, including Department of Transportation regulations. Please refer to www.acuitybrands.com/resources/buy-american for additional information. WARRANTY 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Mounting, Options & Accessories D = 7" H = 9" (Standalone controls) 11" (nLight AIR controls, 2" antenna will be pointing down behind the sensor) W = 11.5" Motion/Ambient Sensor D = 1.75" H = 9" W = 11.5" PBBW – Surface-Mounted Back Box Use when there is no junction box available. D = 0.38" H = 4.4" W = 7.5" AWS – 3/8inch Architectural Wall Spacer Catalog Number Notes Type CONTRACTOR SELECT WF4_WF6 ALO SWW5 SQUARE Page 1 of 3 WF4 & WF6 ALO + SWW5 4" & 6" Flat LED Square Wafers The 4" & 6" flat square wafers with 5CCT Switchable White and ALO technology provide high-quality light output and efficiency while delivering industry leading technology and functionality without the need for a recessed housing. FEATURES: ¡ Next-generation optical technology and design enable precise, even illumination where needed ¡ Canless – no can required; equals easy to install and less labor ¡ With selectable color temperatures ranging from warm (2700K) to daylight (5000K), getting the right look for your space is a breeze ¡ 3 ALO settings allow you to get the perfect amount of light in your space Contractor Select™ Catalog Number UPC Description Replaces Up To Lumens Input Watts CCT CRI Voltage Finish Dimming Protocol Pallet qty. WF4 SQ SM ALO40 SWW5 90CRI MW M6 00198935476455 4" Wafer-Thin LED Square 65W Incandescent 450/550/750 9W 2700K/3000K/3500K/ 4000K/5000k 90 120V Matte White Triac 540 WF6 SQ SM ALO41 SWW5 90CRI MW M6 00198935476516 6" Wafer-Thin LED Square 75W Incandescent 650/850/1000 13W 2700K/3000K/3500K/ 4000K/5000k 90 120V Matte White Triac 360 CAN BE USED TO COMPL Y WITH 2019 JA8 HIGH EFFICACY LED LIGHT SOURCE REQUIREMENTS IC RATED 2700K 3000K 3500K 4000K 5000K SWITCHABLE WHITE DIMMABLE TM 450 LUMENS 550 LUMENS 750 LUMENS Switchable Lumens4" Switchable Lumens 650 LUMENS 850 LUMENS 1000 LUMENS Switchable Lumens6" Switchable Lumens 1 Acuity Way, Decatur, GA 30035 | (800) 705-SERV (7378) | www.acuitybrands.com © 2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/18/26 Page 2 of 3 CONTRACTOR SELECT WF4_WF6 ALO SWW5 SQUARE Accessories: Order as separate catalog number. WF8643 PAN Universal New Construction Pan WF4 PAN R12 4" new construction pan, retail pack of 12 WF6 PAN R12 6" new construction pan, retail pack of 12 WF4GR MW 4" Wafer Goof Ring 4.2" ID x 6.2" OD WF6GR MW JZ 6" Wafer Goof Ring 6" ID x 8" OD WFJB U Remodel Joist Bar WFEXC6 SW3PIN FT4 3-Pin 6ft Cable WFEXC10 SW3PIN FT4 3-Pin 10ft Cable WFEXC20 SW3PIN FT4 3-Pin 20ft Cable Goof rings are made of 22 gauge steel and painted white. WF8643 Universal New Construction Pan Remodel Joist Bar WF4 PAN 4" New Construction Pan WFEXCx FT4 3-Pin Cable WF6 PAN 6" New Construction Pan PERFORMANCE DATA WF4 SQ SM ALO40 SWW5 90CRI MW M6 WF6 SQ SM ALO41 SWW5 90CRI MW M6 High Medium Low High Medium Low Input Power Typical 9W (+/-5%) 7W (+/-5%) 5.5W (+/-5%) 13W (+/-5%) 10W (+/-5%) 7.5W (+/-5%) Input Voltage 120V 120V Frequency 60 Hz 60 Hz EMI/RFI FCC Title 47, Part 15 Class B (consumer) FCC Title 47, Part 15 Class B (consumer) Minimum Starting Temp -40°F (-40°C) -40°F (-40°C) Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25°C. LIGHTING PERFORMANCE DATA DONNÉES SUR LE RENDEMENT DE L'ÉCLAIRAGE Light Appearance (CCT) Aspect de la lumière (CCT) Color Accuracy (CRI) Précision des couleurs (CRI) 90 Light Output (Lumens) Nominal Puissance lumineuse (Lumens) Watts 450 5.5 550 7 750 9 2700K soft white | blanc doux 3000K warm white | blanc chaud 3500K neutralw hite | blanc neutre 4000K cool white | blanc froid 5000K daylight| lumière du jour LIGHTING PERFORMANCE DATA DONNÉES SUR LE RENDEMENT DE L'ÉCLAIRAGE Light Appearance (CCT) Aspect de la lumière (CCT) Color Accuracy (CRI) Précision des couleurs (CRI) 90 Light Output (Lumens) Nominal Puissance lumineuse (Lumens) Watts 650 7.5 850 10 1000 13 2700K soft white | blanc doux 3000K warm white | blanc chaud 3500K neutralw hite | blanc neutre 4000K cool white | blanc froid 5000K daylight| lumière du jour 1 Acuity Way, Decatur, GA 30035 | (800) 705-SERV (7378) | www.acuitybrands.com © 2026 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/18/26 Page 3 of 3 CONTRACTOR SELECT WF4_WF6 ALO SWW5 SQUARE HOUSING: Aluminum die cast outer frame. Durable, powder coat paint to prevent rust • FT4 3-pin plenum rated cable connector to connect from module to remote driver box • Steel spring clip for easy installation. 4" or 6" cut out template is provided to ensure a correct sized hole is cut into ceiling for proper installation of the trim. Size of hole should not exceed 4-1/4" for the WF4 and 6-1/4" for the WF6 • Can be installed from 3/8" to 1 ½" ceiling thickness • Can be removed from below the ceiling for service or replacement. LED LIGHT ENGINE: Low/Medium/High lumen output settings and choice of 2700K, 3000K, 3500K, 4000K or 5000K color temperatures • 90 CRI minimum • Color accuracy within 4 step McAdams Ellipse at the end CCT (2700K and 5000K), within 6 step McAdams Ellipse in the middle CCT (3000K, 3500K, and 4000K) • Dimming 100% to 10% with most standard incandescent dimers (see list of approved dimmers). DRIVER: Connect directly to 120V Class-2 (CAN ICES-005 (B) / NMB-005 (B)) LED driver • 120V 60 Hz constant current driver provides noise free operation • IC rated driver with convenience of a switch to choose between 5 selectable color temperature options ranging from 2700K (warm white), 3000K, 3500K, 4000K, or 5000K (daylight) • The isolated driver integrated inside steel remote box with four 7/8" knockouts with slots for pryout. Suitable for pulling wires with the 12 cubic-inch wiring compartment to accommodate up to (6) 14 gauge insulated conductor or (4) 12 gauge insulated conductors, making the Wafer LED Downlights much easier to wire in 2in/2out (plus ground) daisychain applications and contractor friendly • 2" plenum space required for the installation of the WF6 driver box; 3"plenum space required for the installation of the WF4 driver box • Suitable for installation in t-grid and drop ceiling applications with universal new construction pan. OPTICAL SYSTEM: Edge-lit technology is used to distribute light comfortably into the occupancy space. • Polycarbonate lens provides even illumination throughout the space • Efficient system that can produce over 750 lumens while using 9W with the WF4 and over 1000 lumens while using 13W with the WF6 • Replaces 65W incandescent (WF4) and 75W incandescent (WF6). LIFE: Rated for 50,000 hours at 70% lumen maintenance. LABELS: CSA certified to US and Canadian safety standards • ENERGY STAR® certified product • Suitable for wet location, covered ceiling • Air-Loc certified in accordance with ASTM E283-2004 • NOM Certified • Can be used to comply with California Title 24 Part 6 High Efficacy LED light Source Requirements • U.S. Patent No. 10,681,784. TESTING: All reports are based on published industry procedures; field performance may differ from laboratory performance. WARRANTY: 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms- and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Specifications Dimensions HOLE CUTOUT SIZE WF4 4.25" WF6 6.25 2.3" 4" 4.75" 1.1" 3.9" 6" 6.7" 1.1" WF4 6.02'' 3.03" 1.30" WF6 PLANNING & ZONING LLC 1 TOWN OF BROOKFIELD STAFF REP ORT TO: Town of Brookfield Architectural Review Committee FROM: Rebekah Leto, AICP, Town Planner MEETING DATE: August 12, 2026 (ARC) REPORT DATE: August 6, 2026 RE: Development approval (Conceptual/Preliminary/Final) for Restoration Hardware in The West End, 20351 W. Bluemound Road, Tax key No(s) BKFT1123.004 and .005 APPLICANT: IM Properties (Wisconsin 1) LLC, Robert Gould PROPERTY OWNER: Newfield Holdings LLC and Brookfield Corners LLC The following report is provided for cursory review prior to action. Specifics relating to the submitted documents of this application may be referenced in the Meeting Packet distributed by the Clerk. The applicants are seeking Conceptual, Preliminary and Final approval for Restoration Hardware, a high-end home furnishing company. The anchor tenant will be located in a standalone, single-story building on the north site of the West End, which is approximately 18,798 sq. ft . In addition to home furnishing, there is a full service fine dining restaurant and bar in the center of the showroom, with capacity for approximately 124 guests. Restoration Hardware will be applying for a Class B liquor license. Hours of Operation for the Design Gallery and Restaurant: Monday-Saturday, 10:00 am to 10:00 pm, with the last seating at 9:00 pm Sunday: 10:00 am to 9:00 pm, with the last seating at 8:00 pm. Architecture: The color palette is very light, with different color beiges. Large clear windowpanes with canvas awnings are proposed on each side of the building. A glass skylight is proposed over a portion of the dining area. The proposed building materials include a stone base (Texas Limestone), bronze aluminum window and door trim, beige canvas awnings, and EIFS for the walls, which is a wall cladding system that combines insulation with a smooth protective finish, which improves energy efficiency. Rooftop mechanicals are proposed on the west side of the roof. The applicant has submitted a section view showing how cars from Barker Road will not be able to see the equipment. Site Plan: The entrance to the building is on the east elevation, which will be seen from the Lord Street entrance to The West End. Parking is located between Lord Street and the building. An ADA ramp is provided from the parking to the The West End – Final PLANNING & ZONING LLC 2 building, as a small staircase is needed to account for the grade change. The sidewalk from W. Bluemound Road is extended south onto the subject property and connects to the pedestrian walkways within the development with crosswalks. The site plan matches what was submitted and reviewed on the development plans for The West End. Loading: Loading and unloading will occur near the rear of the building on Union Street and will primarily be for the restaurant. The street will be coned off early in the morning and deliveries are expected 1-2 per week. Traffic and Access: Access to the site is off of Union Street. Appropriate traffic flows and signage are shown on the plans. Parking: Parking for this development was accounted for in consideration with the entire West End development and is consistent with the approved overall development plans. There are 26, 9’x18’parking stalls, with two handicap stalls. Dumpsters: The dumpsters are proposed on the west side of the building, nearest the Barker Road and Bluemound Road intersection. The enclosure is made with the same material as the building, with solid gates on the south end and a service door on the east end. The waste generated will primarily be from the restaurant use. Open Space and Landscaping. A landscape plan has been submitted that includes four Swamp White Oaks around the north and east sides of the parking lot and 16 Regal Prince Oak trees surrounding the remainder of the building. Six (6) Winter Gem Boxwood planters will line the front elevation. Shamrock Inkberry Holly and Blue Rug Junipers will line the sidewalk from W. Bluemound Road to Lord St. The landscape palette is made up of all greenery, which is the brand preference of Restoration Hardware, whose sites consist of beiges, black and greens to tie into an Italian aesthetic. The applicant has submitted calculations showing the amount of green space on site, including native plantings . The amount of green space exceeds what is permitted by code (15%) for the parking area. Lighting All gallery lighting will be on a centralized dimming system with automated daily on/off controls. All interior and exterior lighting will be dimmable. Exterior lighting includes recessed step lighting on the stairs up to the entrance, in-ground grazing wall washers to emphasizing the building façade (as opposed to illuminating it) and in -ground up lighting around the doors and windows. All exterior lights are LED with a CCR of 2700 Kelvin. Sconces on the building are custom fixtures that do not contain cut sheets or photometric information. However, the effect is to create soft illumination on the building rather than actually light the building. Parking lot lighting mirrors what was approved with The West End. The Town Engineer had no concerns with the proposed lighting plan. Signage The West End – Final PLANNING & ZONING LLC 3 Restoration Hardware is proposing very minimal signage. “RH” will be located on the east wall elevation over the entrance doors and the west wall elevation facing Barker Road. The letters are jet black aluminum letters mounted to the wall. The letters will be halo-lit, with 5000K LED lights. While a whiter temperature, the signs are so small, the effect should not be impactful to drivers and do not face living units. The signs are each 11 sq. ft., with each letter being 5.5 sq. ft. (18” x 22”). The maximum wall sign permitted is 102 SF. The sign s complies with the sign code. Recommendation Staff recommends Conceptual, Preliminary and Final Approval of the single-story retail and restaurant use for Restoration Hardware, proposed on the north end of The West End development, located at 20351 W. Bluemound Road. The plans are consistent with the overall development plans f or The West End and will offer high-end retail and dining experiences for visitors of The Corners and The West End. The plans are complete with little to no revisions required from Town Staff. Enclosures: Plans PROJECT LOCATION N © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 TITLE SHEET & PROJECT INFORMATION T1 -01 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 ARCHITECT RINKA INC. 756. N MILWAUKEE STREET SUITE 250 MILWAUKEE, WI 53202 (414) 431 -8101 SHEET INDEX GENERAL ARCHITECTURAL A1-01 MASTER PLAN A1-02 SITE PLAN A1-03 FLOOR PLAN A1-04 ROOF PLAN A2-01 EXTERIOR ELEVATIONS A2-02 EXTERIOR ELEVATIONS A2-03 TRASH ENCLOSURE A2-04 BUILDING PERSPECTIVES A3-01 SECTIONS T1-01 TITLE SHEET & PROJECT INFORMATION RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION ISSUE DATE - 6/17/2026 PROJECT LOCATION MAP CIVIL CONCEPTUAL RENDERING C1 -01 EXISTING CONDITIONS C1 -02 SITE DEMOLITION PLAN C2 -01 SITE PLAN C3 -01 GRADING PLAN C4 -01 SANITARY PLAN & PROFILE C4 -02 WATERMAIN PLAN & PROFILE C4 -03 WATERMAIN PLAN & PROFILE C4 -04 STORM SEWER PLAN C4 -05 UTILITY PLAN C5 -01 PAVING PLAN - NORTHEAST C5 -02 PAVING PLAN - SOUTHEAST C5 -03 PAVING PLAN - SOUTHWEST C5 -04 PAVING PLAN - NORTHWEST C6 -01 CONSTRUCTION DETAILS LANDSCAPE L101 LANDSCAPE PLAN CIVIL ENGINEER PINNACLE ENGINEERING GROUP 20725 WATERTOWN ROAD SUITE 100 BROOKFIELD, WI 53186 (262) 754 -8888 LANDSCAPE KIMLEY -HORN 10 S. ALMADEN BLVD, SUITE 1250, SAN JOSE, 95113 (408) 785 -3518 LIGHTING LT -1.0 EXTERIOR LIGHTING PLAN AREA OF WORK © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 MASTER PLAN A1 -01 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/4" = 1' -0" 1 MASTER PLAN NOT TO SCALE N 18.0' 866 869 875 865 866 867 868 869 870 870 875 876 876 876 877 878 879 880 881 882 877 878 879 874 866 866 865 865 865 865 872 866 866 868 867 866 128' - 0" TRASH ENCLOSURE 149' - 8" DN 1 A3-01 PROPOSED 20' WATER MAIN EASEMENT PROPOSED 20' SANITARY SEWER EASEMENT W BLUEMOUND RD N LORD ST NOT IN SCOPE 15' - 3 1/2" 22' - 3" 15' WEPCO EASEMENT TRANSFORMER UNION ST AREA OF WORK © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 SITE PLAN A1 -02 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/16" = 1' -0" 1 SITE PLAN N BEVERAGE COOLER 1100LB NUGGET ICE 900LB CUBE ICE DISH WASH GW WALK-IN COOLER R/F F EURODIB W W A2 -01 1 A2 -01 2 149' - 8" JAN CL./ CLEANING GSS 1 A3-01 128' - 0" 8' - 0" CLG (11' - 6") GALLERY 22' - 3" X 21' - 0" CLG (11' - 6") DESIGN 17' - 9" X 21' - 0" SHIP/REC 13' - 11" X 13' - 2" BREAK RM 11' - 4" X 13' - 2" LEADER OFFICE 5' - 0" X 8' - 0" CHANGING/ MOTHER'S RM 5' - 1" X 8' - 0" DRY STORAGE 7' - 4" X 6' - 8" HOSPITALITY OFFICE 9' - 9" X 6' - 1" ELEC 6' - 6" X 12' - 7" CLG (11' - 6") GALLERY 21' - 0" X 21' - 0" CLG (11' - 6") GALLERY 20' - 5" X 20' - 2" MDF 6' - 1" X 9' - 2" CLG (11' - 6") GALLERY 23' - 9" X 21' - 0" CLG (11' - 6") GALLERY 19' - 9" X 15' - 5" CLG (11' - 6") GALLERY 19' - 9" X 7' - 7" CLG (11' - 6") GALLERY 19' - 9" X 15' - 5" CLG (11' - 6") GALLERY 20' - 11" X 39' - 9" CLG (11' - 6") GALLERY 20' - 8" X 20' - 2" CLG (11' - 6") GALLERY 20' - 11" X 20' - 2" CLG (11' - 6") GALLERY 123' - 8" X 20' - 2" CLG (11' - 6") GALLERY 38' - 6" X 18' - 7" CLG (11' - 6") GALLERY 20' - 11" X 20' - 2" CLG (11' - 6") GALLERY 20' - 8" X 20' - 2" CLG (11' - 6") GALLERY 19' - 9" X 15' - 5" CLG (11' - 6") GALLERY 19' - 9" X 7' - 7" CLG (11' - 6") GALLERY 19' - 9" X 15' - 5" CLG (11' - 6") GALLERY 23' - 9" X 21' - 0" CLG (11' - 6") GALLERY 14' - 9" X 21' - 0" CLG (11' - 6") GALLERY 19' - 11" X 20' - 2" CLG (11' - 6") GALLERY 17' - 8" X 20' - 2" KITCHEN 44' - 8" X 20' - 3" WINE 44' - 8" X 20' - 3" CLG (26' - 3 1/2") RESTAURANT 37' - 8" X 39' - 10" 8' - 0" LOCKERS 13' - 1" X 8' - 0" CLG (11' - 6") GALLERY 20' - 11" X 39' - 9" SWATCH 7' - 6" X 8' - 4" 76 LOCKERS COAT CL. BENCH PIPP PIPP CLG (11' - 6") GALLERY 14' - 9" X 21' - 0" LINEN STORAGE 6' - 4" X 4' - 6" SUPPLIES/ PAPER STORAGE SS SS HS CLG (11' - 6") PRESENTATION 18' - 10" X 10' - 8" MDP W/D COATS/ RESTAURANT STORAGE W/D A2 -03 3 A2 -03 5 A2 -03 2 A2 -03 4 A2 -02 1 A2 -02 2 © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 FLOOR PLAN A1 -03 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/8" = 1' -0" 1 FLOOR PLAN N A2 -01 1 A2 -01 2 1 A3-01 A2 -03 3 A2 -03 5 A2 -03 2 A2 -03 4 A2 -02 1 A2 -02 2 ROOFTOP MECHANICAL EQUIPMENT ZONE © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 ROOF PLAN A1 -04 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/8" = 1' -0" 1 ROOF PLAN N LEVEL 1 +0' - 0" 22" T.O. CORNICE +22' - 8" T. O. PARAPET +27' - 0 1/2" 4' - 4 1/2" 5' - 2" 6' - 4" 11' - 2" T.O. SKYLIGHT +29' - 8 3/32" <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <CS -1> <F -1> <CS -1> <CS -1> <CS -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> STREET LEVEL +10' - 6" 34 3/4" LEVEL 1 +0' - 0" T.O. CORNICE +22' - 8" T. O. PARAPET +27' - 0 1/2" 11' - 2" 6' - 4" 5' - 2" 4' - 4 1/2" T.O. SKYLIGHT +29' - 8 3/32" <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <CS -1> <CS -1> <CS -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> STREET LEVEL +10' - 6" 22" 34 3/4" MATERIAL KEY PLAN EIFS -1CS -1 F-1SF -1 EIFS © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 EXTERIOR ELEVATIONS A2 -01 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 3/16" = 1' -0" 1 SOUTH ELEVATION SCALE: 3/16" = 1' -0" 2 NORTH ELEVATION SCALE: 3/16" = 1' -0" 2 WEST ELEVATION SCALE: 3/16" = 1' -0" 1 EAST ELEVATION LEVEL 1 +0' - 0" T.O. CORNICE +22' - 8" T. O. PARAPET +27' - 0 1/2" 11' - 2" 6' - 4" 5' - 2" 4' - 4 1/2" T.O. SKYLIGHT +29' - 8 3/32" <EFIS -1> <CS -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <CS -1> <CS -1> <CS -1> <CS -1> <CS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> STREET LEVEL +10' - 6" LEVEL 1 +0' - 0" T.O. CORNICE +22' - 8" T. O. PARAPET +27' - 0 1/2" 11' - 2" 6' - 4" 5' - 2" 4' - 4 1/2" T.O. SKYLIGHT +29' - 8 3/32" <EFIS -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <F -1> <CS -1> <CS -1> <CS -1> <CS -1> <CS -1> <CS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> <EFIS -1> STREET LEVEL +10' - 6" MATERIAL KEY PLAN EIFS -1CS -1 F-1SF -1 EIFS © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 EXTERIOR ELEVATIONS A2 -02 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 3/16" = 1' -0" 1 EAST ELEVATION SCALE: 3/16" = 1' -0" 2 WEST ELEVATION SCALE: 3/16" = 1' -0" SOUTH ELEVATION SCALE: 3/16" = 1' -0" NORTH ELEVATION 9' - 0" <EFIS -1> 9' - 0" <EFIS -1> <EFIS -1> 9' - 0" 9' - 0" <EFIS -1> A2 -03 3 A2 -03 5 A2 -03 2 A2 -03 4 PROPOSED LOCATION FOR ELECTRICAL BOX GREASE INTERCEPTOR MATERIAL KEY PLAN EIFS -1CS -1 F-1SF -1 EIFS © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 TRASH ENCLOSURE A2 -03 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/2" = 1' -0" 2 TRASH ENCLOSURE - WEST ELEVATION SCALE: 1/2" = 1' -0" 3 TRASH ENCLOSURE - EAST ELEVATION SCALE: 1/2" = 1' -0" 4 TRASH ENCLOSURE - SOUTH ELEVATION SCALE: 1/2" = 1' -0" 5 TRASH ENCLOSURE - NORTH ELEVATION SCALE: 3/8" = 1' -0" 1 ENLARGED TRASH ENCLOSURE N SCALE: 1/2" = 1' -0" 6 TRASH ENCLOSURE EXAMPLE NOT TO SCALE © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 BUILDING PERSPECTIVES A2 -04 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1/2" = 1' -0" 4 EAST PERSPECTIVE SCALE: 1/2" = 1' -0" 3 NORTH PERSPECTIVE SCALE: 1/2" = 1' -0" 2 EAST PERSPECTIVE - NIGHT SCALE: 1/2" = 1' -0" 1 SOUTHEAST PERSPECTIVE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BUILDING PERSPECTIVES REFLECT BUILDING DESIGN, NOT LANDSCAPE LEVEL 1 +0' - 0" LEVEL 1 +0' - 0" ROOF +19' - 6 1/2" ROOF +19' - 6 1/2" T. O. PARAPET +27' - 0 1/2" T. O. PARAPET +27' - 0 1/2" STREET LEVEL +10' - 6" STREET LEVEL +10' - 6" TRASH ENCLOSURE 6' - 0" ROOFTOP MECHANICAL EQUIPMENT ZONE 6' - 7" 179' - 0" N BARKER RD © Sheet # Sheet Title Revisions 756 North Milwaukee Street, Suite 250 Milwaukee, Wisconsin 53202 p 414.431.8101 150 W. Jefferson Avenue., Suite 1300 Detroit, MI, US 48226 norr.com 2026 The Corners of Brookfield 20111 W Bluemound Road Brookfield, WI 53045 SECTIONS A3 -01 RH MILWAUKEE 20351 W. Bluemound Rd, Brookfield, WI MUNICIPAL SUBMISSION Date Issued: 6/17/2026 RINKA project #: 23203.01 SCALE: 1" = 10' -0" 1 SOUTH SECTION DO NOTENTER STOP S LORD ST N LORD ST I-94 OFFRAMP W. BLUEMOUND ROAD STH 18 BARKER ROAD PROPOSED BUILDINGFF = 869.30 PROPOSED BUILDINGFF = 865.25LOWER LEVELFF = 842.25 14 7 4 14 7 17 8 7 155 6 PROPOSED UPPERPARKING BUILDINGFF = 879.58 PROPOSED LOWERPARKING BUILDINGFF = 869.42 PROPOSED 20' SANITARYSEWER EASEMENT PROPOSED 20' SANITARYSEWER EASEMENT PROPOSED 20' WATERMAIN EASEMENT PROPOSED 20' WATERMAIN EASEMENT PROPOSED 20' WATERMAIN EASEMENT PROPOSED 12' GASEASEMENT PROPOSED 12' GASEASEMENT 45°' 45°' 45°' 45°' 45°' 24.0'18.0' 18.0' 18.0' 24.0'17.0' 5.8' 24.0'17.0' 11.0'20.1' 8.0' 6.0' 24.0'24.0' 9.0' 24.0' 24.0'9.0' 24.0' 17.0' 9.0' 9.0'9.0' 17.0'9.0'9.0' 22.0' 22.0' 18.0'9.0'24.2' 10.5' 24.0' 18.0'9.0' 4.0' R10.0' R10.0'R10.0'R10.0'R10.0' R20.0'R20.0' R20.0' R8.0' R2.0' R8.0' R10.0' R5.0' R2.0' R3.0' R2.0' R4.0'R10.0'R10.0' R25.0'R5.0'R2.0'R42.0' R2.0'R5.0' R5.0' R5.0' R5.0' R15.0'R79.0'R101.0' R2.0'R5.0'11.8' 4.0' R10.0' 6.1' 81.4' 128.3' 163.7' 33.8' 516.4' R10.0' R5.0'9.0'18.0'9.0'6.0'12.0'18.0'5.0'5.0' 9.0' 6.0'O.C.(TYP.) 6.0'O.C.(TYP.) 126.8' 149.3' 9.0'6.0' 9.0'8.0'R60.0' EXISTING MEDIAN ISLAND CURB AND PAVEMENTTO REMAIN EXISTING RETAININGWALL TO REMAIN PROPOSEDRETAINING WALL LIMITS OF UNDERGROUNDADDITION18" CURB & GUTTER INTERGAL CURB WALK CONCRETE WALK CONCRETE WALK APPROXIMATELIMITS OF WORK APPROXIMATELIMITS OF WORK PAVER WALK CONCRETE WALK CONCRETE WALK18" VERTICAL FACECURB & GUTTER 18" VERTICALFACE CURB &GUTTER 18" CURB & GUTTER CONCRETE WALK18" CURB & GUTTER BOLLARDS, TYP. INTEGRAL CURB & GUTTERTO BE INSTALLED IN KIND. BOLLARDS, TYP. CONCRETE WALK 18" CURB & GUTTER INTEGRAL CURB &GUTTER TO BEINSTALLED IN KIND.INTEGRAL CURB &GUTTER TO BEINSTALLED IN KIND.EXISTING ADA STALLSIGNS TO BE REUSED PROPOSED STRIPEDCROSSWALK (TYP) PROPOSEDLIGHTPOLE (TYP.) PROPOSEDLIGHTPOLE (TYP.) PROPOSEDLIGHTPOLE (TYP.) 18" VERTICALFACE CURB &GUTTER 18" VERTICAL FACECURB & GUTTER ARROWS TO BE PAINTED TRANSFORMER EXISTING UNDERGROUNDGARAGE LIMITSEXISTING UNDERGROUNDGARAGE LIMITS BUILDING OVERHANG BUILDING OVERHANG PROPOSED TYPE 3ADA RAMP ACCESSIBLE PARKINGSTALL AND SIGNAGE ACCESSIBLE PARKINGSTALLS AND SIGNAGE ACCESSIBLE PARKINGSTALL AND SIGNAGE PROPOSED PLANTER(TYP) BOLLARDS,TYP. PROPOSED RAISEDCROSSWALK PROPOSED PLANTER(TYP) CONCRETE WALK PROPOSED TYPE 3ADA RAMP PROPOSEDTRANSFORMERPROPOSEDGENERATOR 18" VERTICAL FACECURB & GUTTER ARROWS TO BEPAINTED CONNECT TOEXISTING SIDEWALK PROPOSED CROSSWALKTHROUGH MEDIAN ARROWS TO BE PAINTED CONNECT TO EXISTINGCURB & GUTTER PROPOSED STOP SIGN PROPOSEDSTOP SIGN PROPOSED STOP SIGN PROPOSED STOP SIGNPROPOSED NOTRUCKS SIGN GAS METERSBOLLARDS,TYP. PROPOSEDTRANSFORMERPROPOSED GREASEINTERCEPTOR ANDTRASH ENCLOSURE PROPOSEDTRANSFORMER PROPOSEDRELOCATEDTRANSFORMERLOCATIONPROPOSEDUTILITY POLE PROPOSEDTRANSFORMERRELOCATEDTRANSFORMERLOCATION THE CORNERS OFBROOKFIELD:PHASE II20111 W BLUEMOUND ROADBROOKFIELD, WI 53045RINKA project #: 23203 1" = 20'040' GRAPHICAL SCALE (FEET)NORTH PINNACLEENGINEERINGGROUP WISCONSIN OFFICE:20725 WAERTOWN ROAD, SUITE 100BROOKFIELD, WI 53186(262) 754-8888 PEG PROJECT NO: 1987.00DC2-01 DESIGNDEVELOPMENTSET Sheet #Sheet Title Revisions 756 North Milwaukee Street, Suite 250Milwaukee, Wisconsin 53202p 414.431.8101NOT FOR CONSTRUCTION 2025© SITE PLANDate Issued: 05/22/2026 SITE DATA TABLEPROPOSED PARKING STALL COUNT:- SURFACE PARKING: 103 STALLS7 ADA STALLS- TOTAL SURFACE PARKING: 103 STALLSLEGENDREGULAR DUTY PAVEMENT(SEE DETAILS SHEET) 16PARKING COUNT (FOR INFORMATION ONLY, NOT TO BE PAINTED)CONCRETE SIDEWALK(SEE DETAILS SHEET)PAVERS(SEE DETAILS SHEET)STREET SIGNL PROJECT TEAM CONTACTSAPPLICANT:TOM KAFKES, VP OF CONSTRUCTION MANAGEMENTIM PROPERTY INVESTMENTS (USA) LLC77 WEST WACKER DRIVE, SUITE 4500CHICAGO, IL 60601(312) 620-1660LANDOWNER:PARCELS 1 & 2NEWFIELD HOLDINGS LLC270 N LORD STBROOKFIELD, WI 53045-3300LANDOWNER:PARCEL 3BROOKFIELD CORNERS LLC270 N LORD STBROOKFIELD, WI 53045-3300 CIVIL ENGINEER:AARON KOCH, P.E.PINNACLE ENGINEERING GROUP20725 WATERTOWN ROAD, SUITE 100BROOKFIELD, WI 53186(262) 754-8888SURVEYOR:JOHN KONOPACKI, P.L.S.PINNACLE ENGINEERING GROUP20725 WATERTOWN ROAD, SUITE 100BROOKFIELD, WI 53186(262)754-8888DEVELOPER:ROBERT B. MONNAT, SENIOR PARTNERMANDEL GROUP330 EAST KILBOURN AVENUE, SUITE 600SOUTHMILWAUKEE, WI 53202(414) 270-2741 FX11 FX11 FX11FX11 FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11 FX11FX11 FX11 FX11FX11 FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11 FX11FX11 FX11FX11 FX11FX11 FX8FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11 FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8 FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8FX8 FX8FX8FX8FX8FX8FX8 FX8FX8FX8FX8 FX8FX11FX11FX11FX11 FX11FX11FX8FX8FX8FX8 FX8FX8FX8FX8FX8FX8FX8FX8 FX13FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX11FX8FX8FX8FX8FX8FX8FX11FX11 (N) TRASH ENCLOSURE DN 128' - 0" 149' - 8" BEVERAGECOOLER 1100LBNUGGETICE900LBCUBEICE DISHWASHGW WALK-INCOOLER R/FFEURODIB WW 128'-0"(N) TRASH ENCLOSURE149'-8" DN FX8FX8 FX15FX15FX15FX15FX15FX15FX8FX8FX8FX8 FX8FX8FX8FX8 LIGHTING LEGENDTYPESYMBOLDESCRIPTIONLOCATIONQUANTITYFX8IN-GROUND UPLIGHTDOOR AND WINDOW JAMBS, LANDSCAPETBDFX11IN-GROUND GRAZING WALL WASHERBUILDING FACADE UPLIGHTSTBDFX15RECESSED STEP LIGHTMAIN ENTRANCETBDNOTES FOR ZONING AND LIGHTING CONTROLS:1.ALL GALLERY LIGHTING TO BE ON CENTRALIZED DIMMING SYSTEM WITH AUTOMATED DAILY ON/OFF CONTROLS.2.ALL INTERIOR AND EXTERIOR LIGHTING TO BE DIMMABLE. DIMMING LEVELS TO BE SET BY LIGHTING DESIGNER AND APPROVEDBY CLIENT.3.EXTERIOR LIGHTING: ONE ZONE PER "F" TYPE, PER INSTALLATION LOCATION, LEVEL OR CONDITION (UNLESS OTHERWISENOTED ON DRAWINGS). FOR EXAMPLE, "FX8" UPLIGHTING TREES, WALLS AND DOORWAYS WOULD ALWAYS BE ON SEPARATEZONES. REV. DATE.DESCRIPTION 06.12.2026100% SCHEMATIC SITE LIGHTING 3/32" = 1'-0"EXTERIOR LIGHTING PLAN1PROJECT: rkvDESIGN23823 MALIBU ROADSUITE 50 - #212MALIBU, CA 90265www.rkv-design.com+1 310 924 2185 NOTES FOR GENERAL CONTRACTOR:1.General Contractor (GC) and ElectricalContractor (EC) will be responsible forverification of all dimensions, specifications andcoordination with related trades andsubcontractors.2.GC to notify designer of any conflict withmechanical, electrical, plumbing, HVAC orstructural presence or any conflicting dimensionsor site conditions prior to commencement ofwork.3.GC is responsible for notifying designer of anyinconsistencies between design drawings andother documents.4.Do not scale drawings. RH MILWAUKEEGALLERY AT THE CORNERS20351 W. BLUEMOUND RD.BROOKFIELD, WIDRAWING TITLE:SHEET:EXTERIORLIGHTING PLANLT-1.0 rkv DESIGN LIGHTING SPECIFICATION PACKAGE RH MILWAUKEE THE GALLERY AT THE CORNERS 20351 W. BLUEMOUND RD, BROOKFIELD, WI SITE LIGHTING PACKAGE 06.12.2026 rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 2 TTyyppee DDeessccrriippttiioonn MMaannuuffaaccttuurreerrMMooddeell NNaammee && NNuummbbeerr FFiinniisshh WWaatttt LLaammpp LLooaadd TTyyppee NNootteess LLooccaattiioonn FX8 Grade recessed LED uplight with inetgral transformer HK Lighting CZXGi-RH-LED-NSS-LVR16- 2700-33 5W Integral LED 2700K 33° optic MLV, Dimmed Exterior, landscape lighting FX11 Lumenfacade Ingound 24" nominal uplight with clear lens, internal louvre, anti-slip lens, approx. 2205lm Lumenpulse LOI-HO-120/277-24-27K- 10x30-TSO-INTL-DIM-ASL Stainless Steel and glass 15.25 W/ft LED 80 CRI 2700K 10°x30° optic 0-10V Exterior, façade uplight FX13 Pole top luminaire with asymmetric wide beam light distribution, 3710lm mounted to 6" straight round hinged pole, 16' high, rated to 6sq.ft EPA @120mph Bega 99402-BLK-K27 916HR Black - architect to confirm 16W Integral LED 80 CRI 2700K 0-10V Architect to verify pole height and fixture locations with existing trees, property lines Parking area FX15 Horizontal rectangle LEDme Wall recessed path light WAC Lighting WL-LED 100 - 27-FINISH Stainless steel 3.5W Integral LED 90 CRI 2700K ELV, Dimmed Entrance steps TTyyppee DDeessccrriippttiioonn MMaannuuffaaccttuurreerrMMooddeell NNaammee && NNuummbbeerr FFiinniisshh WWaatttt LLaammpp LLooaadd TTyyppee NNootteess LLooccaattiioonn FX8 Grade recessed LED uplight with inetgral transformer HK Lighting CZXGi-RH-LED-NSS-LVR16- 2700-33 5W Integral LED 2700K 33° optic MLV, Dimmed Exterior, landscape lighting FX11 Lumenfacade Ingound 24" nominal uplight with clear lens, internal louvre, anti-slip lens, approx. 2205lm Lumenpulse LOI-HO-120/277-24-27K- 10x30-TSO-INTL-DIM-ASL Stainless Steel and glass 15.25 W/ft LED 80 CRI 2700K 10°x30° optic 0-10V Exterior, façade uplight FX13 Pole top luminaire with asymmetric wide beam light distribution, 3710lm mounted to 6" straight round hinged pole, 16' high, rated to 6sq.ft EPA @120mph Bega 99402-BLK-K27 916HR Black - architect to confirm 16W Integral LED 80 CRI 2700K 0-10V Architect to verify pole height and fixture locations with existing trees, property lines Parking area FX15 Horizontal rectangle LEDme Wall recessed path light WAC Lighting WL-LED 100 - 27-FINISH Stainless steel 3.5W Integral LED 90 CRI 2700K ELV, Dimmed Entrance steps rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 3 FX8 WET/DRY LOCATION • Stylish in grade LED up light with contemporary design. • Anti-corrosion inner/outer sleeve. Stainless steel lens bezel and protective trim. • Ozone, aging and weather resistant silicone gaskets are used to hermetically seal and protect the fixture. • Stainless Steel hardware • MLV dimmable. • Indoor/Ourdoor application. • Ideal for concrete pour or core-drilled floor • Built with integral magnetic step down transformer for 120VAC input • Modified overall height - 8.00" • No bottom steel flange SPECIFICATION CODE MATERIAL: Bezel: SERIES: CZXG MODEL: RH-LED CZXG-RH-LED 316 Stainless Steel lens and outer bezel Housing: FINISHES: Stainless Steel NSS Anti-corrosion inner housing/outer sleeve Lamp Holder: Machined Aluminum Resistant to corrosion ACCESSORIES: Hexcel Louver LVR16 Stainless steel (SS304) hardware VOLTAGE: 120 VAC WATTAGE: 5W HK LED LAMP: HK LED COLOR TEMP: 2700K / 3000K / 4000K CATALOG # SAMPLE: CZXGi-RH-LED SOCKET: HK LED socket DIMMING: MLV BEAM ANGLE: 20°, 33°, 42°, 57° PROJECT: TYPE: CZXGi-RH-LED-8" 5WLED uplight NOTE: Specifications and Dimensions subject to change without notice. HK LIGHTING GROUP 3529 Old Conejo Road, #118 Newbury Park, CA 91320 Phone: 805-480-4881 Fax: 805-480-4811 E-mail: sales@hklightinggroup.com A A 8.00" ◼ 3.96" . Fixture Manufacturer: Cat #: Lamp Manufacturer: Type: Capitol Light is not responsible for inaccuracies in manufacturers published specifications Client: HK Lighting ZXGI-RH-LED-120-5-27-33-NSS-LVR-8" N/A LED INCL FX8Cat #: rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 4 FX11 Specification Sheet Lumenfacade Inground LOI WHIT E AND ST AT IC COLOR S 1220 Marie-Victorin Blvd., Longueuil, QC, J4G 2H9, CAN   |   T 514.937.3003  |  Toll-Free 1.877.937.3003   |   in fo@lu m en pu lse.com www.l umenpul se.com       www.l umenpul se.com/products/4881 LMPG Inc. reserves the right to make changes to thi s product at any time without prior notice and such m odification sh all be effective im m ediately. 2024.11.20 Copyright © 2024 LM P G Inc. JC - R25 1  /  11 D u mmy The Lumenfacade Inground is an LED luminaire designed for ground-recessed lighting applications, including asymmetric wall washing, grazing, and linear wayfinding. An in novative, plug and play design simplifies installation, protecting the system from water infiltration and ensuring long-lasting performance. Featuring second generation LED technology, the Lumenfacade Inground is available in four different sizes (12 in, 24 in, 36 in or 48 in), with a wide choice of outputs, color temperatures, color-mixing systems, optics and controls. A unique asymmetric wallwash distribution is also available, providing exceptional uniformity and brightness for walls and signage. Description Project Name Qty Type Catalog / Part Number Top view Front and side views Photometric Summary Optics Construction Walk over compliant up to 500 kg in any type of ground, Walk over compliant up to 1000 kg in concrete Features Color and Color Temperature 2200K, 2700K, 3000K, 3500K, 4000K, Red, Green, Blue Length (Nominal) 12 in, 24 in, 36 in, 48 in Optics Asymmetric wallwash, 8° x 8°, 10° x 10°, 10° x 30°, 10° x 60°, 10° x 90°, 15° x 25°, 30° x 30°, 30° x 60°, 35° x 35°, 50° x 80°, 60° x 60°, 80° x 80°, 90° x 90° Tilt Setting (factory set) 0 degrees, 2.5 degrees, 5 degrees, 20 degrees Optical Option Internal louver Option Anti-slip lens CE (certification covers European Economic Area) Power Consumption 5 W/ft (meets ASHRAE standards for linear lighting on building facades - not available for 12 in fixture lengths), 8.5 W/ft (RO version), 15.25 W/ft (HO version), Typically 20% higher for 12 in fixture lengths Warranty 5-year limited warranty rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 5 FX11 Specification Sheet Lumenfacade Inground LOI WHIT E AND ST AT IC COLOR S 1220 Marie-Victorin Blvd., Longueuil, QC, J4G 2H9, CAN   |   T 514.937.3003  |  Toll-Free 1.877.937.3003   |   in fo@lu m en pu lse.com www.l umenpul se.com       www.l umenpul se.com/products/4881 LMPG Inc. reserves the right to make changes to thi s product at any time without prior notice and such m odification sh all be effective im m ediately. 2024.11.20 Copyright © 2024 LM P G Inc. JC - R25 2  /  11 Colors and Color Temperatures Control Ratings Certifications Maximum Delivered Output 4,730 lm (48 in fixture, 4000K, 30° x 30°, 0° tilt setting, DMX/RDM) Performance Maximum Delivered Intensity 59,238 cd at nadir (48 in fixture, 4000K, 8° x 8°, 0° tilt setting, DMX/RDM) Illuminance at Distance Minimum 1 fc at 243 ft (48 in fixture, 4000K, 8° x 8°, 0° tilt setting, DMX/RDM) Color Consistency 2 SDCM, 3 SDCM (2200K) Color Rendering Minimum CRI 80 Lumen Maintenance L70 280,000 hrs L95 35,000 hrs Optical Chamber Material Aluminum Physical Blockout Material Polymer recycled PVC reinforced with a stainless steel frame Trim Material Anodized aluminum Lens Material Tempered glass End Cap Material Die cast aluminum Hardware Material Stainless steel Weight 12 in: 7.5 lbs 24 in: 15.3 lbs 36 in: 21.4 lbs 48 in: 27 lbs Voltage 120 to 277 volts Electrical and Control Fixture Cable Power and data in one cable Leader Cable Conductor 5C #16-5 Connectors IP68 push-lock Control On/Off Control, Lumentalk, 0-10V Dimming, DALI dimming, DMX/RDM enabled Resolution (DMX/RDM) Per foot or per fixture (configured with LumenID V3 software), 8- bit or 16-bit Storage Temperature -40 °F to 185 °F (device must reach start-up temperature value before operating) Environmental Start-up Temperature -13 °F to 122 °F Operating Temperature -40 °F to 122 °F Ingress Protection Rating IP68 rated for up to 1 ft, not suitable for permanent immersion applications Impact Resistance Rating IK10 rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 6 FX11 Specification Sheet Lumenfacade Inground LOI WHIT E AND ST AT IC COLOR S 1220 Marie-Victorin Blvd., Longueuil, QC, J4G 2H9, CAN   |   T 514.937.3003  |  Toll-Free 1.877.937.3003   |   in fo@lu m en pu lse.com www.l umenpul se.com       www.l umenpul se.com/products/4881 LMPG Inc. reserves the right to make changes to thi s product at any time without prior notice and such m odification sh all be effective im m ediately. 2024.11.20 Copyright © 2024 LM P G Inc. JC - R25 3  /  11 Chromaticity Data TM-30 - 4000K Spectral Power Distribution Optical Chamber Orientation Cables Lumenfacade Inground Leader Cable, Lumenfacade Inground Jumper Cable Accessories (Order Separately) Electrical Accessories Lumenfacade Inground Junction Box Control Boxes DMX/RDM enabled (Daisy Chain or Star Configuration), Ethernet enabled (Daisy Chain or Star Configuration) Control Systems Pharos® kit (PHAROS), Lumenscene™ (LSC) Diagnostic and Addressing Tools LumenID (LID), LumentalkID (LIDLT) rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 7 FX11 Specification Sheet Lumenfacade Inground LOI WHIT E AND ST AT IC COLOR S 1220 Marie-Victorin Blvd., Longueuil, QC, J4G 2H9, CAN   |   T 514.937.3003  |  Toll-Free 1.877.937.3003   |   in fo@lu m en pu lse.com www.l umenpul se.com       www.l umenpul se.com/products/4881 LMPG Inc. reserves the right to make changes to thi s product at any time without prior notice and such m odification sh all be effective im m ediately. 2024.11.20 Copyright © 2024 LM P G Inc. JC - R25 4  /  11 Cables (Order Separately) LOILC - Leader Cable For Lumenfacade Inground LOILC-CERTIFICATION-LENGTH Please specify: CERTIFICATION: UL or CE; LENGTH: 10 ft, 25 ft or 50 ft Suitable for dimming/data and non-dimming applications. Consult Lumenfacade Inground leader cable specification sheet for details. LOIJC - Jumper Cable For Lumenfacade Inground LOIJC-CERTIFICATION-LENGTH Please specify: CERTIFICATION: UL or CE; LENGTH: 2 ft, 4 ft or 10 ft Suitable for dimming/data and non-dimming applications. Consult Lumenfacade Inground jumper cable specification sheet f or details. Jumper Cable Length Selection D - distance between two fixtures L - length of fixture Add the length of one fixture to the distance between two fixtures: L + D. Order the next longest jumper cable available: 2 ft, 4 ft or 10 ft. Example: if the distance between two 4 ft fixtures is 0.5 ft, L + D = 4.5 ft, therefore a 10 ft jumper cable is required. rkv DESIGN RH MILWAUKEE SITE LIGHTING | 06.12..2026 page 8 FX15 Fixture Type: Catalog Number: Project: Location: WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DEC 2021 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 Model: WL-LED100 LEDme® Step Light FEATURES • Solid diecast brass, corrosion resistant aluminum alloy, or cast stainless steel construction • Direct wiring, no driver needed • • 54,000 hour rated life • Balanced lighting, free of shadows with minimum glare • IP66 rated, Protected against high-pressure water jets • • 5 year WAC Lighting product warranty ORDER NUMBER 120V Model # Light Color Finish WL-LED100 120V C AM RD BL White Amber Red Blue 3000K 27 Warm 2700K 610nm 640nm 450nm BK BN* BZ GH SS WT Black on Aluminum Brushed Nickel on Aluminum Bronze on Aluminum Graphite on Aluminum Stainless Steel White on Aluminum WL-LED100 120V C AM White Amber 3000K 27 Warm 2700K 610nm BBR Bronze on brass *Brushed Nickel Finish is for interior use only 277V Model # Light Color Finish WL-LED100F 277V C AM RD BL White Amber Red Blue 3000K 610nm 640nm 450nm BK BN* BZ GH SS WT Black on Aluminum Brushed Nickel on Aluminum Bronze on Aluminum Graphite on Aluminum Stainless Steel White on Aluminum – – Example: WL-LED100F-BL-SS PRODUCT DESCRIPTION Horizontal rectangle LEDme® Step Light. Designed for safety and style on stairways, patios, decks, balcony areas, walkways and building perimeters. indoor and outdoor lighting solutions. Creates an attractive, romantic impression at night. 5" 3" 2a" 18" front 12" 18" x" 2" side 1d" 22" back SPECIFIC ATIONS Construction: Die-cast aluminum or 316 marine grade cast stainless steel Power: Direct wiring, no remote driver needed. Input voltage: 120V or 277VAC 50/60Hz Light Source: 2700K or 3000K CCT Samsung HV-AC High Power LED, CRI: 90 Optional color lenses. Total power consumption of 3.5W Mounting: Fits into 2” × 4” J-Box with minimum inside dimensions of 3"L × 2"W × 2"H Includes bracket for J-Box mount. Dimming: Dim to 10% with electronic low voltage (ELV) dimmer Approved dimmers: Lutron Nova-T NTELV-300 & NTELV-600, Lutron Vietri VTELV-600, Lutron Diva DVELV-300P, Lutron Skylark SELV-300P, Lutron Maestro MAELV-600 Standards: IP66, UL & cUL Listed for wet locations, Title 24 JA8-2016 Compliant. 2"NPT threaded hole The West - RHSite Lighting Designer JAS Date 06/15/2026 Scale Not to Scale Drawing No. Summary V3.1 1 of 1 All light levels are approximate. Values will vary due to actual LED/driver combinations, reflectances (currently set at 70/30/20), environmental conditions, and obstructions. Calculations are based on our interpretation of information provided to us. This design remains the property of Spectrum Lighting and may not be altered without written permission. 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.2 0.4 0.5 0.6 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.3 0.5 0.8 0.9 1.1 1.0 0.9 0.7 0.4 0.2 0.1 0.2 0.4 0.6 1.0 1.4 1.6 1.6 1.3 0.8 0.5 0.2 0.2 0.4 0.7 1.1 1.5 1.5 1.7 1.4 0.9 0.5 0.2 0.1 0.2 0.4 0.7 1.1 1.6 1.8 1.9 1.4 0.9 0.5 0.2 0.1 0.1 0.1 0.3 0.5 0.7 1.1 1.5 1.7 0.2 0.3 0.4 0.6 0.7 0.9 1.0 1.1 0.4 0.5 0.6 0.6 0.7 0.8 0.8 0.8 0.6 0.7 0.8 0.8 0.8 0.7 0.6 0.5 0.8 1.0 1.0 1.0 0.9 0.7 0.5 0.3 1.1 1.1 1.2 1.4 0.9 0.6 0.4 0.2 1.1 1.1 0.9 1.3 1.0 0.7 0.4 0.2 1.1 1.2 1.3 1.4 0.9 0.6 0.4 0.2 1.0 1.1 1.2 1.1 0.9 0.6 0.4 0.2 0.7 0.8 0.8 0.8 0.7 0.5 0.3 0.2 0.5 0.6 0.6 0.5 0.5 0.4 0.3 0.2 0.3 0.4 0.4 0.4 0.5 0.4 0.3 0.3 0.1 0.2 0.2 0.3 0.4 0.5 0.5 0.5 0.6 0.3 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.7 0.8 0.9 0.9 0.2 0.1 0.1 0.2 0.4 0.6 0.9 1.2 1.3 2.2 0.5 0.3 0.2 0.4 0.7 1.0 1.7 1.7 1.9 1.4 0.9 0.5 0.2 0.1 0.1 0.1 0.3 0.5 1.0 2.0 3.4 4.3 1.4 0.5 0.1 0.2 0.5 0.7 1.2 1.5 0.7 1.9 1.6 1.0 0.7 0.2 0.2 0.2 0.4 2.0 1.8 0.6 0.1 0.2 0.4 0.7 1.1 1.7 1.8 0.3 0.4 0.4 1.1 0.5 0.1 0.2 0.4 0.6 0.5 0.3 0.1 0.2 0.3 0.5 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.3 0.1 0.1 0.2 0.3 0.5 1.0 2.9 3.8 1.1 0.5 0.1 0.1 0.2 0.5 1.4 2.1 2.8 1.6 1.4 2.2 4.0 2.3 4.4 2.5 1.5 1.4 2.3 4.0 2.0 1.8 0.6 0.1 0.1 0.4 1.1 3.6 4.1 2.6 1.3 0.8 0.8 1.3 1.9 1.5 0.8 0.7 1.0 2.0 3.4 4.3 1.4 0.5 0.1 0.2 0.5 1.8 2.3 2.0 1.2 0.7 0.5 0.6 0.8 0.6 0.5 0.6 0.9 1.6 2.1 2.2 0.5 0.3 0.1 0.1 0.2 0.7 1.2 1.2 0.8 0.5 0.3 0.3 0.3 0.3 0.3 0.4 0.7 1.0 1.1 0.9 0.2 0.1 0.1 0.1 0.3 0.5 0.6 0.5 0.3 0.2 0.1 0.1 0.1 0.2 0.3 0.4 0.5 0.5 0.3 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.6 1.1 2.2 4.0 2.0 1.6 1.1 0.7 0.5 0.5 0.7 1.2 2.1 3.3 3.8 0.9 1.2 1.5 1.6 1.6 1.3 1.0 0.8 0.6 0.6 0.6 0.7 0.9 1.3 1.9 2.2 2.0 0.7 0.9 1.3 1.7 1.7 1.5 1.3 1.2 1.1 1.1 1.0 1.1 1.2 1.5 1.8 1.9 1.4 0.5 0.8 1.6 2.3 2.1 1.7 1.6 1.8 2.1 2.2 2.1 1.9 1.6 1.6 2.0 2.2 2.0 3.5 2.7 1.8 1.7 2.2 3.3 4.0 3.5 2.4 1.7 1.6 2.2 3.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 4.5 FS2 @ 16' FS2 @ 16'FS1 @ 16'FS1 @ 16' FS2 @ 16' FS2 @ 16' EX-FS1 @ 19' Plan View Scale - 1" = 20ft Statistics Description Avg Max Min Max/Min Avg/Min Parking Area 1.7 fc 4.5 fc 0.3 fc 15.0:1 5.7:1 Property 0.4 fc 4.5 fc 0.0 fc N/A N/A Schedule Symbol Label QTY Manufacturer Catalog Number Description Lumens per LampLLF Wattage FS1 2 Lumec MPTC-72W32LED3K-G3- LE5 UrbanScape LED Post-Top (MPTC),Type V (68W/30K) 7306 1 68 FS2 4 Lumec MPTC-72W32LED3K-G3- LE4 UrbanScape LED Post-Top (MPTC),Type IV (68W/30K) 7170 1 68 FS1 0 Lumec MPTC-72W32LED3K-G3- LE3W UrbanScape LED Post-Top (MPTC),Type III (68W/30K) 7204 1 68 EX- FS1 1 Lumec MPTC-72W32LED3K-G3- LE5 EXISTING UrbanScape LED Post-Top (MPTC),Type V (68W/30K) 7306 1 68 *No substitutions shall be allowed without prior approval from engineer of record and lighting designer. This drawing represents visual design concepts only, and is not intended to be a final drawing for construction or other purposes. Spectrum Lighitng is not providing any professional opinion or advice on whether this concept design is appropriate from a structural, lighting or electrical standpoint, and will not assume responsibility for improper engineering, construction, handling, or use. It is the responsibility of the owner to verify that all materials and construction comply with the most stringent applicable Federal, State and Local Fire, Safety, Energy, and Environmental Codes, and the owner should seek professional engineering, electrical and other advice before proceeding. All wiring design and installation should be accomplished only by a licensed electrician. This document is provided and intended solely for this particular location, and duplication or use for any other purpose is strictly prohibited.

Source: Town of Brookfield website. First collected Oct 8, 2026.