Communications Advisory Technical Subcommittee (CATS) Meeting Agenda Packet (PDF)
Door County · Door County · meeting of Oct 28, 2026 · Agenda packets
Open the original document More from Door County
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
In compliance with the Americans with Disabilities Act, any person needing assistance to participate in this meeting, should contact the Office of the County Clerk at
(920)746 2200. Notification 48 hours prior to a meeting will enable the County to make reasonable arrangements to ensure accessibility to that meeting.
_________
AGENDA
1. Call Meeting to Order
2. Establish a Quorum
3. Adopt Agenda / Properly Noticed
4. Approve Minutes of the 12/17/2025 meeting
5. Public Comment
6. New Business
6.1 New 800MHz System Project
6.1.1 Status
6.1.2 Frequency Reservation
6.2 2026 Nsight Tower Inspection Review
7. Matters to be Placed on a Future Agenda or Referred to a Committee, Official, or Employee
8. Next CATS Committee Meeting Date: To be determined
9. Adjourn
Deviation from the order shown may occur
Notice of Public Meeting
October 28th. 2026
11:00 A.M.
COMMUNICATION
ADVISORY TECHNICAL
SUB-COMMITTEE
Door County Justice Center
Multi-Purpose Room
1201 S Duluth Ave
Sturgeon Bay, WI 54235
Public Safety Committee is the Oversight Committee for Communication Advisory Technical Sub-Committee
.
Call Meeting to Order
The Wednesday December 17th meeting was called to order by Chairperson
Elizabeth Gauger at the Door County Government Center at 9:00 am.
Establish a Quorum
Members Present: Howie Hathaway, Aaron LeClair, Ashley DeGrave, Greg Diltz,
Joseph Saelens, Kyle Veeser, Brenda Bley, Elizabeth Gauger
Others Present
Jason Baudhuin Bay Electronics - Remote, Ken Pabich, Len Koehnen, Jason Rouer
Adopt Agenda / Properly Noticed
Motion made by Diltz second by LeClair to approve the agenda. Motion carried by voice vote.
Approve Minutes of the 5/28/2025 meeting
Motion made by LeClair second by Diltz to approve the minutes from the May 28th meeting. Motion carried by
voice vote.
Public Comment
New Business
Fish Creek Tower Update
DeGrave reviewed status of Fish Creek Tower and explained punch list items were completed when contractor
was on-site last week. Consultant, Len Koehnen, reviewed his final site walk and said the project is closed out
from his perspective. He did advise to double check on an entrance gate by the tennis courts.
New 800 MHz System Project Update
Status
DeGrave reviewed site acquisition status. Explained Sevastopol is approved and studies being
completed, Baileys Harbor is awaiting official offer documents, and remaining sites are still working on
specific sites. She explained along with site acquisition, some existing site reviews have begun. Dig to
block was completed on Sunnyslope and anchor supports are in excellent condition. Evaluations should
be completed every 5YRS to keep up site integrity. DeGrave also explained the EMS Central Site
modification is moving forward. Edge was on-site last week to gather final information to prepare bid
documents.
DeGrave explained conversations with Brown County on partnership opportunities are continuing.
Pabich explained evaluating a shared core option with Brown as well as a possible cloud solution.
Discussion continued including concerns with service on the current Highway RF system and how
MINUTES
December 17th, 2025
COMMUNICATION
ADVISORY TECHNICAL
SUB-COMMITTEE
Door County Government Center
County Board Room
421 Nebraska St
Sturgeon Bay, WI 54235
Public Safety Committee is the Oversight Committee for Communication Advisory Technical Sub-Committee
“These minutes
have not been
reviewed by the
oversight
committee and are
subject to approval
at the next regular
committee
meeting.”
.
partnership would work. Pabich explained hoping to have vendor determination by end of 2nd QTR 2026
and will start a workgroup to start discussing system specifications.
Concerns that were expressed will be investigated further and more information brought at the next
meeting.
Frequency Reservations
No action/discussion.
Committee Appointment
DeGrave explained that a replacement for Chris Hecht’s seat is being evaluated. Kalin Montevideo to bring topic
up at next Fire Chiefs meeting to determine replacement options. Once replacement is identified, it can be taken
to County Board for official assignment.
2025 Nsight Tower Inspection Review
DeGrave advised Nsight’s reports were part of the agenda packet. No major concerns/repairs for this year.
Some rusty hardware and unlevel antennas were identified. DeGrave will review if that equipment is County or
one of the tenants and notify them accordingly.
2025 Bay Electronics System Review
DeGrave reviewed Bay Electronics inspection summary sheet included in the packet. Advised no major issues
during evaluation. Jason Bauduin (Bay Electronics) stated no major issues and all minor adjustments were
recorded for the record. Baudhuin also explained that site batteries were replaced as part of the inspections.
Hathaway verified that there were no antenna issues at the Brussels site this year.
Matters to be Placed on a Future Agenda or Referred to a Committee, Official, or Employee
Next CATS Committee Meeting Date: TBD – 1st Quarter 2026
Adjourn
Motion made by Diltz second by Hathaway to adjourn. Motion carried by voice vote at 9:42 am.
Respectfully submitted by: Ashley DeGrave
Countywide SAR Talk Out % SAR Talk In %
800 MHz Portable Countywide 98.63 99.71
Contractor-Guaranteed Percentage of Service Area Reliability for Radio Coverage
(Portable, 1/4-Wave on Hip at 3.3' AGL, 10.5dB Body Loss, Outdoors, 3.4 DAQ)
Polygon Area
Baileys Harbor Outdoor Polygon Service Area 98.47 99.97
Brussels Outdoor Polygon Service Area, Portable 98.57 99.90
Chambers Island Outdoor Polygon Service Area 99.20 99.99
City of Sturgeon Bay_1 Outdoor Polygon Service Area 99.44 99.73
City of Sturgeon Bay_2 Outdoor Polygon Service Area 99.96 99.99
Clay Banks Outdoor Polygon Service Area 97.96 98.76
Detroit Island Outdoor Polygon Service Area 97.65 99.92
Town of Egg Harbor Outdoor Polygon Service Area 97.53 99.61
Town of Forestville Outdoor Polygon Service Area 99.81 99.88
Town of Gardner Outdoor Polygon Service Area 98.00 99.53
Town of Gibraltar Outdoor Polygon Service Area 99.38 99.61
Town of Jacksonport Outdoor Polygon Service Area 98.67 99.98
Town of Liberty Grove Outdoor Polygon Service Area 98.76 99.93
Town of Nasewaupee Outdoor Polygon Service Area 99.81 99.79
Town of Sevastopol Outdoor Polygon Service Area 98.41 99.69
Town of Sturgeon Bay_1 Outdoor Polygon Service Area 99.85 99.71
Town of Sturgeon Bay_2 Outdoor Polygon Service Area 99.94 99.97
Town of Union Outdoor Polygon Service Area 98.21 99.33
Village of Egg Harbor Outdoor Polygon Service Area 97.22 98.51
Village of Ephraim Outdoor Polygon Service Area 98.29 98.96
Village of Forestville Outdoor Polygon Service Area 99.59 99.23
Village of Sister Bay Outdoor Polygon Service Area 99.94 99.83
Washington Island Outdoor Polygon Service Area 95.39 99.31
Countywide SAR Talk Out % SAR Talk In %
800 MHz Portable Countywide 98.49 99.68
Contractor-Guaranteed Percentage of Service Area Reliability for Radio Coverage
(Portable, 1/4-Wave on Hip at 3.3' AGL, 10.5dB Body Loss, Outdoors, 3.4 DAQ)
Polygon Area
Baileys Harbor Outdoor Polygon Service Area 98.47 99.97
Brussels Outdoor Polygon Service Area 98.57 99.90
City of Sturgeon Bay_1 Outdoor Polygon Service Area 99.44 99.73
City of Sturgeon Bay_2 Outdoor Polygon Service Area 99.96 99.99
Clay Banks Outdoor Polygon Service Area 97.96 98.76
Detroit Island Outdoor Polygon Service Area 97.65 99.92
Town of Egg Harbor Outdoor Polygon Service Area 97.53 99.61
Town of Forestville Outdoor Polygon Service Area 99.81 99.88
Town of Gardner Outdoor Polygon Service Area 98.00 99.53
Chambers Island Outdoor Polygon Service Area 87.27 97.22
Town of Gibraltar Outdoor Polygon Service Area 99.38 99.61
Town of Gibraltar (Combined) Outdoor Polygon Service Area 95.68
Town of Jacksonport Outdoor Polygon Service Area 98.67 99.98
Town of Liberty Grove Outdoor Polygon Service Area 98.76 99.93
Town of Nasewaupee Outdoor Polygon Service Area 99.81 99.79
Town of Sevastopol Outdoor Polygon Service Area 98.41 99.69
Town of Sturgeon Bay_1 Outdoor Polygon Service Area 99.85 99.71
Town of Sturgeon Bay_2 Outdoor Polygon Service Area 99.94 99.97
Town of Union Outdoor Polygon Service Area 98.21 99.33
Village of Egg Harbor Outdoor Polygon Service Area 97.22 98.51
Village of Ephraim Outdoor Polygon Service Area 98.29 98.96
Village of Forestville Outdoor Polygon Service Area 99.59 99.23
Village of Sister Bay Outdoor Polygon Service Area 99.94 99.83
Washington Island Outdoor Polygon Service Area 95.39 99.31
Coverage Estimates as of October 2026
SAR Talk Out % SAR Talk In %
WITH CHAMBERS ISLAND
WITHOUT CHAMBERS ISLAND
SAR Talk Out % SAR Talk In %
"Dedicated to Excellence"
(920) 617-7100
TOWER INSPECTION REPORT
Overall site report and recommendations
Page 1
Padlocks on guy anchor fences are rusting and sticking
debris throughout compound
exposed weed barrier throughout compound
Compound Fence is leaning inward on east side
Client:
compound fence barb wire is rusted on main compound and around guy anchors
feeline cable is unsecured for too far of a distance and routed outside of and rubbing on safety climb cable
rusted hardware on dish mount at 195' BC face
multiple unused mounts and securement throughout entire tower
LEG A
LEG C LEG B
804'
1060055
guyed
400'
Star represents Safety Climb and arrow shows
orientation to North
Additional Info:
Manufacturer ID Number:
Tower Manufacturer:
Tower Height ('):
Tower Type:
FCC Registration Number:
Elevation (AMSL)('):
Longitude:
Latitude:
Jarred S Ryan X
10/8/2026
Access Notes:
Combo or Key:
Access Requirements:
Site Contact:
Site Owner:
Site Number:
State:
County:
City: Egg Harbor
Door County
Wi
44.982357
-87.28234
5475 Glendale Ave.
Overall Tower Photo
Tower Orientation
Door County
N/A
N/A
Green Bay WI,
Nsight Tower
Inspection Date:
Inspectors:
Site Name:
54313
Door County
Sunny Slope
X Applicable Fields
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
x
N/A
X N/A
X N/A
X N/A
X N/A
II. Tower Conditions (Guyed, Self-Support, Monopole)
I. Site Compound Conditions
Attached
Picture #
Page 2
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Attached
Picture #
Compound:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
Access Road Entrance:
Site Access Road:
Anchor Bolts:
Concrete Condition:
Grouting Condition:
Base Condition:
Ground Conditions:
D. Tower Base Foundation
Ground Leads:
Corrosion:
Connections:
C. Grounding
Standing water on site or tower:
Color compliance conditions:
Rust/corrosion conditions:
Paint/galvanizing condition:
B. Finish
Loose and/or missing bolts:
Climbing Facilities and Safeties:
Missing Members:
Loose Members:
Bent Members:
INSPECTION ITEM
Compound Fence:
Grounding at Inspection Well:
Grounding at Telco Entrance:
Grounding at Electrical Entrance:
Grounding at Fence:
Grounding at Ice Bridge:
Grounding at Equipment Building:
Waveguide Bridge & Foundation:
Propane Tank & Foundation:
Generator & Foundation:
Building & Foundation:
Power & Telco Runs:
Erosion Control:
Trash Removal:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS FAIL
PASS FAIL
PASS
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL Comment #7
PASS FAIL
PASS
PASS
PASS
PASS FAIL
PASS FAIL
PASS FAIL
ITEM CONDITION
A. Members
Comment #
ITEM CONDITION
Comment #5
Comment #1,2,3
Comment #4
PASS
PASS
PASS
PASS
PASS
PASS
INSPECTION ITEM
PASS
PASS
FAIL
FAIL
Comment #
Lightning Rod PASS FAIL
PASS FAIL
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
PASS
PASS FAIL
PASS FAIL
IV. Guyed Tower
V. Antennas and Feedlines
PASS FAIL
PASS FAIL
Page 3
PASS FAIL Comment #6
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL Comment #8
Grounding:
Kinks or flat spots:
Connections & Seals:
Spare Cables secured properly:
Overall Radio condition:
Hangers & Supports:
C. Feedlines
Radios secured adequately:
Antenna Condition:
Antennas brackets:
Mount steel and hardware:
A. Antennas and Radios
PASS FAIL
Comment #
Attached
Picture #
III. Tower Lighting
FAIL
INSPECTION ITEM ITEM CONDITION
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
B. Guy Wires
Anchor Rod Condition:
Shackles, bolts, pins, cotter pins:
Cable Connectors:
Cable Thimbles:
Turnbuckles:
Condition:
FAIL
FAIL
FAIL
Condition of Sidelights: PASS
Beacons Sync'd:
Photo Cell Operation:
PASS FAIL
Drainage:
Grounding:
Corrosion Control Measures:
Anchor Rod Condition:
PASS FAIL
PASS FAIL
PASS
FAIL
Condition of Wiring:
Condition of Junction Box:
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
A. Guy Anchors
FAIL
PASS FAIL
Settlement: PASS FAIL
Condition of Conduit/SO Cord:
PASS
PASS
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
PASS FAILCondition of Beacon:
Condition of Strobes: PASS
PASS FAIL
PASS FAIL
Leg
Leg
LegElevation Ground N/A
Issue Recommendations
replace posts with longer ones or add concrete
Detailed Site Analysis
Related PhotoIssue Details
Issue Summary
Compound fence is leaning inward and
The posts wiggle in and out in the ground
Comment 1
Elevation Ground N/A
Page 4
Comment 2
Issue Details Related Photo
Issue Summary
compound fence barb wire is rusted on main compound
as well as multiple guy anchor fences
Issue Recommendations
replace compound fence barb wire
Comment 3
Issue Details Related Photo
Issue Summary
NW guy anchor fence corner post is bent and damaged
causing door to not work properly and barb wire to slack
Issue Recommendations
replace corner post
Elevation Ground N/A
Leg
Leg
Leg
Comment 5
Issue Details Related Photo
Elevation
Comment 6
Issue Details
Comment 4
Issue Details Related Photo
Elevation Ground N/A
Issue Summary
garbage in compound including used generator oil filter
a concrete pillar and a pipe
Issue Recommendations
clean compound debris
Ground N/A
Issue Summary
Weed barrier is showing through gravel in multipe spots
throughout compound
Issue Recommendations
add gravel to compound
Related Photo
Elevation 195 B-C face
Issue Summary
rusted dish mount hardware
Issue Recommendations
replace hardware
Leg
Leg
Page 5
Comment 7
Issue Details Related Photo
Elevation 397 A-B face
Issue Summary
antenna feedline is unsecured for too far and routed
around and rubbing on safety climb cable
Issue Recommendations
Re route and better secure cable
Comment 8
Issue Details Related Photo
Elevation multiple multiple
Issue Summary
multiple random unused securement and mounts
throughout tower
Issue Recommendations
"Dedicated to Excellence"
(920) 617-7100
TOWER INSPECTION REPORT
Overall site report and recommendations
Page 1
only problem found is that there is damage to the shelter roof
Client:
LEG A
LEG C LEG B
940
Self Support
130'
Additional Info:
Manufacturer ID Number:
Tower Manufacturer:
Tower Height ('):
Tower Type:
FCC Registration Number:
Elevation (AMSL)('):
Longitude:
Latitude:
Jarred S Ryan X
10/8/2026
Access Notes:
Combo or Key:
Access Requirements:
Site Contact:
Site Owner:
Site Number:
State:
County:
City: Sturgeon Bay
Door County
Wisconsin
44*48'40.2"N
87*23'56.2"W
5475 Glendale Ave.
Overall Tower Photo
Tower Orientation
Door County
Call Dispatch 920-746-2417
Green Bay WI,
Nsight Tower
Inspection Date:
Inspectors:
Site Name:
54313
Door County
Justice Center
Star represents Safety Climb and arrow shows
orientation to North
X Applicable Fields
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
II. Tower Conditions (Guyed, Self-Support, Monopole)
I. Site Compound Conditions
Attached
Picture #
Page 2
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Attached
Picture #
Compound:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
Access Road Entrance:
Site Access Road:
Anchor Bolts:
Concrete Condition:
Grouting Condition:
Base Condition:
Ground Conditions:
D. Tower Base Foundation
Ground Leads:
Corrosion:
Connections:
C. Grounding
Standing water on site or tower:
Color compliance conditions:
Rust/corrosion conditions:
Paint/galvanizing condition:
B. Finish
Loose and/or missing bolts:
Climbing Facilities and Safeties:
Missing Members:
Loose Members:
Bent Members:
INSPECTION ITEM
Compound Fence:
Grounding at Inspection Well:
Grounding at Telco Entrance:
Grounding at Electrical Entrance:
Grounding at Fence:
Grounding at Ice Bridge:
Grounding at Equipment Building:
Waveguide Bridge & Foundation:
Propane Tank & Foundation:
Generator & Foundation:
Building & Foundation:
Power & Telco Runs:
Erosion Control:
Trash Removal:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS FAIL
FAIL
PASS FAIL
PASS FAIL
PASS
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS
PASS
PASS
PASS FAIL
PASS FAIL
PASS FAIL
ITEM CONDITION
A. Members
Comment #
ITEM CONDITION
Comment #1
PASS
PASS
PASS
PASS
PASS
PASS
INSPECTION ITEM
PASS
PASS
FAIL
FAIL
Comment #
Lightning Rod PASS FAIL
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
PASS
PASS FAIL
PASS FAIL
IV. Guyed Tower
V. Antennas and Feedlines
PASS FAIL
PASS FAIL
Page 3
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Grounding:
Kinks or flat spots:
Connections & Seals:
Spare Cables secured properly:
Overall Radio condition:
Hangers & Supports:
C. Feedlines
Radios secured adequately:
Antenna Condition:
Antennas brackets:
Mount steel and hardware:
A. Antennas and Radios
PASS FAIL
Comment #
Attached
Picture #
III. Tower Lighting
FAIL
INSPECTION ITEM ITEM CONDITION
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
B. Guy Wires
Anchor Rod Condition:
Shackles, bolts, pins, cotter pins:
Cable Connectors:
Cable Thimbles:
Turnbuckles:
Condition:
FAIL
FAIL
FAIL
Condition of Sidelights: PASS
Beacons Sync'd:
Photo Cell Operation: FAIL
PASS FAIL
Drainage:
Grounding:
Corrosion Control Measures:
Anchor Rod Condition:
PASS FAIL
PASS FAIL
PASS
FAIL
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
A. Guy Anchors
FAIL
PASS FAIL
Settlement: PASS FAIL
Condition of Wiring:
Condition of Junction Box:
Condition of Conduit/SO Cord:
PASS
PASS
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
PASS FAILCondition of Beacon:
Condition of Strobes: PASS
PASS FAIL
PASS
Leg
Leg
LegElevation
Issue Recommendations
seal or paint damage to prevent water intrusion
Detailed Site Analysis
Related PhotoIssue Details
Issue Summary
damage to shelter roof from falling objects
Comment 1
Elevation Ground N/A
Related Photo
Issue Summary
Issue Recommendations
Elevation
Page 4
Comment 2
Issue Details Related Photo
Issue Summary
Issue Recommendations
Comment 3
Issue Details
#VALUE!
"Dedicated to Excellence"
(920) 617-7100
TOWER INSPECTION REPORT
Overall site report and recommendations
Page 1
Site is in good overall condition
Client:
there are two large bee hives on the tower at 10'
LEG A
LEG C LEG B
18851
775
1286204
Self Support
180'
Nello
Additional Info:
Manufacturer ID Number:
Tower Manufacturer:
Tower Height ('):
Tower Type:
FCC Registration Number:
Elevation (AMSL)('):
Longitude:
Latitude:
Jarred S Caleb P
10/15/2026
Access Notes:
Combo or Key:
Access Requirements:
Site Access:
Site Owner:
Site Number:
State:
County:
City: Union
Door County
Wisconsin
44.70457
-87.68062
5475 Glendale Ave.
Overall Tower Photo
Tower Orientation
Door County
920-746-2416
Green Bay WI,
Nsight Tower
Inspection Date:
Inspectors:
Site Name:
54313
Door County
SW Tower
Star represents Safety Climb and arrow shows
orientation to North
X Applicable Fields
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
II. Tower Conditions (Guyed, Self-Support, Monopole)
I. Site Compound Conditions
IV. Guyed Tower
Attached
Picture #
Page 2
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Attached
Picture #
Compound:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
Access Road Entrance:
Site Access Road:
Anchor Bolts:
Concrete Condition:
Grouting Condition:
Base Condition:
Ground Conditions:
D. Tower Base Foundation
Ground Leads:
Corrosion:
Connections:
C. Grounding
Standing water on site or tower:
Color compliance conditions:
Rust/corrosion conditions:
Paint/galvanizing condition:
B. Finish
Loose and/or missing bolts:
Climbing Facilities and Safeties:
Missing Members:
Loose Members:
Bent Members:
INSPECTION ITEM
Compound Fence:
Grounding at Inspection Well:
Grounding at Telco Entrance:
Grounding at Electrical Entrance:
Grounding at Fence:
Grounding at Ice Bridge:
Grounding at Equipment Building:
Waveguide Bridge & Foundation:
Propane Tank & Foundation:
Generator & Foundation:
Building & Foundation:
Power & Telco Runs:
Erosion Control:
Trash Removal:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS FAIL
FAIL
PASS FAIL
PASS FAIL
PASS
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS
PASS
PASS
PASS FAIL
PASS FAIL
PASS FAIL
ITEM CONDITION
A. Members
Comment #
ITEM CONDITION
PASS
PASS
PASS
PASS
PASS
PASS
INSPECTION ITEM
PASS
PASS
FAIL
FAIL
Comment #
Lightning Rod PASS FAIL
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
Detailed Site Analysis
Related PhotoIssue Details
Comment 1
PASS
PASS FAIL
PASS FAIL
V. Antennas and Feedlines
PASS FAIL
PASS FAIL
Page 3
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Grounding:
Kinks or flat spots:
Connections & Seals:
Spare Cables secured properly:
Overall Radio condition:
Hangers & Supports:
C. Feedlines
Radios secured adequately:
Antenna Condition:
Antennas brackets:
Mount steel and hardware:
A. Antennas and Radios
PASS FAIL
Comment #
Attached
Picture #
III. Tower Lighting
FAIL
INSPECTION ITEM ITEM CONDITION
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
B. Guy Wires
Anchor Rod Condition:
Shackles, bolts, pins, cotter pins:
Cable Connectors:
Cable Thimbles:
Turnbuckles:
Condition:
FAIL
FAIL
FAIL
Condition of Sidelights: PASS
Beacons Sync'd:
Photo Cell Operation: FAIL
PASS FAIL
Drainage:
Grounding:
Corrosion Control Measures:
Anchor Rod Condition:
PASS FAIL
PASS FAIL
PASS
FAIL
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
A. Guy Anchors
FAIL
PASS FAIL
Settlement: PASS FAIL
Condition of Wiring:
Condition of Junction Box:
Condition of Conduit/SO Cord:
PASS
PASS
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
PASS FAILCondition of Beacon:
Condition of Strobes: PASS
PASS FAIL
PASS
Leg
Leg
LegElevation
Issue Recommendations
We did not have wasp spray in the truck so someone
Issue Summary
Two large Bee hives on angles
will have to return with spray or in winter to remove hives
Elevation 10' A-B and A-C
Related Photo
Issue Summary
Issue Recommendations
Elevation
Page 4
Comment 2
Issue Details Related Photo
Issue Summary
Issue Recommendations
Comment 3
Issue Details
"Dedicated to Excellence"
(920) 617-7100
TOWER INSPECTION REPORT
Overall site report and recommendations
Page 1
Tower was in good overall condition.
Client:
Driveway has bad wash outs
Seal tite conduit on propane tank is broken allowing insect and exposing the cable inside
LEG A
LEG C LEG B
18850
725
1285898
Self support
180
Nello
Additional Info:
Manufacturer ID Number:
Tower Manufacturer:
Tower Height ('):
Tower Type:
FCC Registration Number:
Elevation (AMSL)('):
Longitude:
Latitude:
Jarred S Caleb P
10/15/2026
Access Notes:
Combo or Key:
Access Requirements:
Site Contact:
Site Owner:
Site Number:
State:
County:
City: Forestville
Door County
Wi
44.719685
-87.492451
5475 Glendale Ave.
Overall Tower Photo
Tower Orientation
Door County
920-746-2416
Green Bay WI,
Nsight Tower
Inspection Date:
Inspectors:
Site Name:
54313
Door County
Mill Road
Star represents Safety Climb and arrow shows
orientation to North
X Applicable Fields
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
II. Tower Conditions (Guyed, Self-Support, Monopole)
I. Site Compound Conditions
Attached
Picture #
Page 2
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Attached
Picture #
Compound:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS
PASS
PASS
PASS
PASS
PASS
Access Road Entrance:
Site Access Road:
Anchor Bolts:
Concrete Condition:
Grouting Condition:
Base Condition:
Ground Conditions:
D. Tower Base Foundation
Ground Leads:
Corrosion:
Connections:
C. Grounding
Standing water on site or tower:
Color compliance conditions:
Rust/corrosion conditions:
Paint/galvanizing condition:
B. Finish
Loose and/or missing bolts:
Climbing Facilities and Safeties:
Missing Members:
Loose Members:
Bent Members:
INSPECTION ITEM
Compound Fence:
Grounding at Inspection Well:
Grounding at Telco Entrance:
Grounding at Electrical Entrance:
Grounding at Fence:
Grounding at Ice Bridge:
Grounding at Equipment Building:
Waveguide Bridge & Foundation:
Propane Tank & Foundation:
Generator & Foundation:
Building & Foundation:
Power & Telco Runs:
Erosion Control:
Trash Removal:
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
FAIL
PASS FAIL
FAIL
PASS FAIL
PASS FAIL
PASS
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS
PASS
PASS
PASS FAIL
PASS FAIL
PASS FAIL
ITEM CONDITION
A. Members
Comment #
ITEM CONDITION
2
1
1
PASS
PASS
PASS
PASS
PASS
PASS
INSPECTION ITEM
PASS
PASS
FAIL
FAIL
Comment #
Lightning Rod PASS FAIL
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
X N/A
PASS
PASS FAIL
PASS FAIL
IV. Guyed Tower
V. Antennas and Feedlines
PASS FAIL
PASS FAIL
Page 3
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
Grounding:
Kinks or flat spots:
Connections & Seals:
Spare Cables secured properly:
Overall Radio condition:
Hangers & Supports:
C. Feedlines
Radios secured adequately:
Antenna Condition:
Antennas brackets:
Mount steel and hardware:
A. Antennas and Radios
PASS FAIL
Comment #
Attached
Picture #
III. Tower Lighting
FAIL
INSPECTION ITEM ITEM CONDITION
PASS FAIL
PASS FAIL
PASS FAIL
PASS FAIL
B. Guy Wires
Anchor Rod Condition:
Shackles, bolts, pins, cotter pins:
Cable Connectors:
Cable Thimbles:
Turnbuckles:
Condition:
FAIL
FAIL
PASS FAIL
Drainage:
Settlement:
Grounding:
Corrosion Control Measures:
Anchor Rod Condition:
PASS FAIL
PASS FAIL
PASS FAIL
PASS
FAIL
PASS FAIL
PASS FAIL
FAIL
PASS FAIL
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
A. Guy Anchors
FAIL
PASS FAIL
Condition of Sidelights:
Condition of Beacon:
Condition of Strobes: PASS
PASS
Beacons Sync'd:
Photo Cell Operation:
Condition of Wiring:
Condition of Junction Box:
Condition of Conduit/SO Cord:
PASS
PASS
INSPECTION ITEM ITEM CONDITION Comment #
Attached
Picture #
Leg
Leg
LegElevation
Issue Recommendations
add gravel and grade driveway
Detailed Site Analysis
Related PhotoIssue Details
Issue Summary
Driveway has wash outs
Comment 1
Elevation Ground N/A
Related Photo
Issue Summary
Seal tite conduit is broken at propane tank
Issue Recommendations
replace seal tite conduit
Elevation Ground N/A
Page 4
Comment 2
Issue Details Related Photo
Issue Summary
Issue Recommendations
Comment 3
Issue Details