Packet
City of Verona · Dane County · meeting of Nov 4, 2026 · Agenda packets
Open the original document More from City of Verona
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
CITY OF VERONA
111 Lincoln Street
Verona, WI 53593
(608) 845-6495
veronawi.gov
PLAN COMMISSION
DATE: WEDNESDAY, NOVEMBER 4, 2026 TIME: 6:30 PM
LOCATION: COUNCIL CHAMBERS
CITY HALL
111 LINCOLN STREET
VERONA, WI 53593
Call To Order
Roll Call
Public Comment
Minutes
Approval of minutes from October 5, 2026 Plan Commission meeting.
2026-10- 05 PLAN COMMISSION MINUTES.PDF
Lighting Zoning Text Amendment
Public Hearing– Zoning text amendment for Title 13, Chapter 1, Article B – Definitions and Section 13-1-159 regarding exterior lighting.
a. Discussion & Possible Action – Zoning text amendment for Title, 13, Chapter 1, Article B – Definitions and Section 13-1-159 – Performance Standards for Exterior Lighting.
LIGHTING - ZTA.PDF
1979 Milky Way
Discussion & Possible Action – Site plan review for one (1) permanent and one (1) temporary parking lots located at 1979 Milky Way.
1979 MILKY WAY - SITE AND TUP.PDF
Ardent Glen Subdivision
Discussion & Possible Action – Final plat review to create seventy-five (75) lots and five (5) outlots for Ardent Glen Subdivision.
ARDENT GLEN - FINAL PLAT.PDF
140 And 142 Jenna Drive
Discussion & Possible Action – Certified survey map review to create two (2) lots located at 140 – 142 Jenna Drive.
140 AND 142 JENNA DR - CSM.PDF
1694 Range Trail
Discussion & Possible Action – Certified survey map review to create two (2) lots located at 1694 Range Trail.
1694 RANGE TRAIL - CSM.PDF
Urban Service Area Amendment
Discussion & Possible Action – Urban service area (USA) amendment to add approximately 40 -acres of land located at 6500 Shady Bend Road to the City ’s urban service area.
USA AMENDMENT.PDF
Adjournment
Luke Diaz - Chairperson
POSTED: October 28, 2026
POSTED: Verona City Hall
Verona Public Library
Miller ’s Market
All agendas are posted on the City website at: veronawi.gov
WRITTEN COMMENTS: You can send comments to the Plan Commission on any matter, either on or not on the agenda, by emailing lsivertsen@veronawi.gov or in writing to Plan Commission, 111 Lincoln Street, Verona, WI, 53593.
Notice: If you need an interpreter, materials in alternative formats, or other accommodation to access the meeting, please contact the City Clerk at (608) 845 -6495 at least 48 -hours preceding the meeting. Every reasonable effort will be made to accommodate your request.
Notice is hereby given that a majority of the City Council may be present at the meeting of the Plan Commission to gather information about a subject over which they have decision - making responsibility. This constitutes a meeting of the City Council pursuant to the State ex rel. Badke v. Greendale Village Board, 173Wis. 2d 553, 494 N.W. 2d 408 (1993) and must be noticed as such, although the City Council will not take any formal action at this meeting.
1.
2.
3.
4.
Documents:
5.
Documents:
6.
Documents:
7.
Documents:
8.
Documents:
9.
Documents:
10.
Documents:
11.
CITY OF VERONA
PLAN COMMISSION
October 5, 2026
Council Chambers
1. Call to Order: Mayor Diaz called the meeting to order at 6:30 p.m.
2. Roll Call: Linnea Matulat, Tyler Wood, Tyler Powers, Luke Diaz, Michelle Felber,
Lachlann Swanson, and Mike Hankard. Also present: Director of Planning and
Development Lucas Sivertsen.
3. Public Comment:
• Mary Henningfield, 689 Thornton Ter., spoke regarding the Sub-Zero project.
She had concerns about noise, traffic and the 24-hour operations.
4. Approval of minutes from September 8, 2026 Plan Commission meeting.
Motion by Wood, seconded by Swanson to approve the minutes from the
September 8, 2026 Plan Commission meeting. Motion carried 7-0.
5. Discussion & Possible Action – Site plan and certified survey map review for
approximately 5,000 square foot addition located at 201 South Main Street.
Sivertsen explained that Memorial Baptist Church is requesting a two-story addition
to the rear of the property with modified parking and traffic circulation proposed.
The applicant will be dedicating right-of-way for a public sidewalk.
Wood expressed concerns about the driveway and that the dedication of right-of-
way does not follow the sidewalk policy.
Motion by Swanson, seconded by Powers to approve the site plan to allow for the
construction of approximately 4,700 square foot addition with the condition that the
applicant enter into a development agreement with the City to construct a public
sidewalk. Motion carried 6-1 with Wood voting no.
Motion by Swanson, seconded by Powers to recommend that the Common Council
approve the certified survey map to create one lot at 201 South Main Street. Motion
carried 6-1 with Wood voting no.
6. Discussion & Possible Action – Certified survey map review to create one (1) lot
located at 2681 Country View Road.
Motion by Swanson, seconded by Wood to recommend that the Common Council
approve a certified survey map to create one lot located at 2681 Country View Road.
Motion carried 7-0.
7. Discussion & Possible Action – Certified survey map review to create one (1) lot
located at 2506 Spring Rose Road.
Motion by Swanson, seconded by Diaz to recommend that the Common Council
approve a certified survey map to create one lot located at 2506 Spring Rose Road.
Motion carried 7-0.
8. Discussion & Possible Action – Certified survey map review to create two (2) lots
located east of 2157 Davis Hill Drive.
Motion by Powers, seconded by Swanson to recommend that the Common Council
approve a certified survey map to create two lots located east of 2157 Davis Hill
Drive. Motion carried 7-0.
9. Reports and comments from the Planning Department
a. Update on development projects: Sivertsen stated the City received an
application from Sub-Zero which will be on the November agenda.
b. Meetings:
i. Next meeting: Wednesday, November 4
ii. 2027 Plan Commission meeting dates
10. Adjournment: Motion by Wood, seconded by Swanson to adjourn at 6:57 p.m.
Motion carried 7-0.
Respectfully Submitted,
Holly Licht, City Clerk
Memorandum
To: Plan Commission
From: Katherine Holt, Community Development Specialist
Date: October 5, 2026
Re: Lighting Zoning Text Amendment
Staff is proposing a new lighting ordinance to help the City migrate towards dark
skies utilizing key dark-sky principles in a practical and locally tailored manner, but
Staff did not use the Dark Sky International municipal code model. The Sustainability
Task Force and City Staff engaged Scott Lind to review and assist with research
regarding best standards of practice for outdoor lighting. Scott Lind is an electrical
engineer who has assisted other Wisconsin municipalities and organizations in
creating dark sky compliance ordinances and guidelines.
At the same time, Envision Verona: A Comprehensive Plan (“Plan”) was underway
with residents in the City supporting dark skies. The following are quotes regarding
lighting from the Plan:
“Many residents called for the pursuit and implementation of policies and
programs that support environmental protection and community
sustainability, such as encouraging the use of solar panels and electric
vehicle (EV) charging stations, as well as enforcing dark sky compliant
lighting — “Require warm color temperature outdoor lighting” (p. 45).
“Adopt Dark Sky practices to minimize light pollution and encourage
responsible lighting practices for exterior lighting” (p. 121).
“Adopt Dark Sky practices to minimize light pollution and encourage
responsible lighting practices for exterior lighting” (p. 176).
The proposed lighting ordinance adds definitions to help clarify the proposed
language. There are several new and amended sections in the document. It was
recommended to establish lighting zones to help lower lighting levels based on
zoning districts and abutting land uses as well as creating a new maximum
illuminance at property lines per lighting zones. Lighting fixture requirements are
proposed in the ordinance to address various types of fixtures and functions. These
changes support the Plan’s idea of implementing dark sky principles that minimize
light pollution. Changes to the lighting ordinance will be adjusted overtime as this is
2
the first proposed change to implement with the potential for language to be
amended.
The Plan Commission reviewed an initial lighting ordinance last month to allow Staff
to gain feedback on the proposal. Comments from the Plan Commission included
questions regarding grandfathering, dark skies, and recommendations to coordinate
with Dane County Parks Department. At this time, the City does not plan to pursue a
dark skies community certification as there are too many developments that are
grandfathered to meet the requirements; however, this may be pursued overtime as
older lighting fixtures come into compliance with this amendment. There was
discussion around string lighting. Staff will educate property owners to turn off string
lights by nighttime curfew. While existing lighting for single-family and duplex
residences are exempt from meeting the lighting ordinance, education will be the key
for property owners to understand how this can be accomplished when changing out
lighting fixtures especially if the lighting fixtures are swapped out by the property
owner instead of an electrician.
Proposed Language:
Sec. 13-1-44 - Definitions - B.
(e) BUG Rating. A classification system that measures the amount of light
emitted in the Backlight (B), Uplight (U), and Glare (G) zones of a fixture.
BUG ratings are used to evaluate and limit light trespass, sky glow, and glare
from outdoor lighting installations.
Sec. 13-1-54 - Definitions - L.
(i) Light Pollution. Any artificial light that is excessive, misdirected, intrusive, or
unnecessary, including glare, light trespass, sky glow, and other adverse
effects on the nighttime environment.
(j) Lighting, Festoon String. A series of bulbs or LED modules connected by a
cable, wire, or string and suspended between attachment points for
decorative, pedestrian-scale, or ambient outdoor lighting purposes.
(k) Lighting Fixture. A complete lighting unit consisting of one (1) or more
sources of light, together with the housing, mounting components, optics,
reflectors, lenses, and associated equipment designed to distribute, direct, or
control light. Also referred to as a luminaire by lighting professionals.
(l) Lighting, Seasonal. Outdoor or site lighting that is portable, temporary,
decorative, and used in connection with holidays and traditions. This includes
but is not limited to string lighting, icicle lighting, and lighted inflatables, none
of which are intended for general illumination.
3
(m) Lighting Zone. An area designated by this Code for the application of
outdoor lighting standards, including limits on light levels, light trespass,
correlated color temperature (CCT), and lighting controls.
S
ec. 13-1-61 - Definitions - S.
(ii) Sky Glow. The brightening of the nighttime sky caused by the scattering of
artificial light in the atmosphere, reducing the visibility of stars and other
celestial objects.
S
ec. 13-1-63 - Definitions - U.
(b) Uplight. A lighting fixture or lighting technique that directs all or a substantial
portion of its light output upward above the horizontal plane, toward the sky,
building facades, trees, or other objects.
S
ec. 13-1-159 Performance Standards.
(a) Exterior Lighting Standards
1) Applicability
a. The requirements of this subsection apply to all exterior lighting installed,
constructed, reconstructed, enlarged, altered, or replaced within the City
of Verona, except lighting located entirely within public street rights-of-way
under the jurisdiction of the City, Dane County, or the Wisconsin
Department of Transportation
b. This subsection does not apply to interior lighting except where such
lighting causes direct light trespass or glare onto other properties, natural
areas, waters, or into the public right-of-way.
c. Existing nonconforming lighting shall be brought into compliance when the
fixture is replaced, or when related exterior modifications to a building or
site impact existing lighting.
d. Nothing in this subsection shall be interpreted to prevent the use of
lighting that is required by state or federal law.
2) Permit Required. An electrical permit shall apply to the installation or
replacement of outdoor lighting.
a. All development and redevelopment subject to a site plan review shall
demonstrate compliance by submitting a photometric plan to include, but
not limited to, fixture locations, mounting heights, shielding, CCT, BUG
ratings, lumen output, control methods, and photometric calculations
documenting compliance with applicable Lighting Zone limits.
4
b. Minor modifications and residential projects may submit a fixture schedule
in lieu of photometric calculations if the City determines photometric
calculations are not necessary.
3) Establishment of Lighting Zones. Lighting Zones are established for the
purpose of determining compliance with American National Standards
Institute and Illuminating Engineering Society (ANSI/IES) lighting standards
and for setting appropriate maximum correlated color temperature (CCT),
light trespass, and operational controls. Each zoning district established in
Section 13-1-81: Establishment of Zoning Districts is assigned to a Lighting
Zone per Table 13-1-159(1).
Table 13-1-159(1): Lighting Zones
Lighting Zone Zoning Districts and Typical Locations
LZ0 – Protected Areas Conservancies, environmental corridors, parks or open
spaces where preservation of natural darkness is a primary
objective; environmentally sensitive portions of RA - Rural
Agricultural or PI - Public Institutional properties as
designated by the City.
LZ1 – Low-Light Residential
and Agricultural
RA; NR - Neighborhood Residential; MR - Mixed Residential;
PI areas of low-intensity public parks and open space not
designated LZ0.
LZ2 – Moderate Activity Areas UR - Urban Residential; NO - Neighborhood Office; SO -
Suburban Office; PI; SC - Suburban Commercial; PD –
Planned Development or PD -L – Planned Development
Legacy areas with residential, office, civic, institutional, or
moderate commercial character.
LZ3 – High Activity
Commercial and Industrial
CC - Central Commercial; SI -Suburban Industrial; UI - Urban
Industrial; PD or PD-L areas with downtown, entertainment,
industrial, or high nighttime activity character.
4) Planned Development. Where a parcel is located within a Planned
Development Overlay District (PD), the underlying zoning district or the
character of the approved planned development shall determine the
applicable Lighting Zone. The Zoning Administrator may assign a lower
Lighting Zone where a site contains or abuts environmentally sensitive lands,
residential uses, parks, open space, waterways, or other areas where lower
light levels are appropriate.
5) Lighting Zone Performance Standards.
5
Table 13-1-159(2): Lighting Zone Performance Standards.
Lighting Zone Maximum Correlated
Color Temperature (CCT)
Maximum Illuminance at
Property Line
Typical Character
LZ0 – Protected Areas 1800 Kelvin (K) 0.05 footcandle (fc) Natural or environmentally
sensitive areas; lighting should be
avoided unless needed for safety.
LZ1 – Low-Light
Residential and
Agricultural
2700 K 0.10 fc Residential, agricultural, and low-
intensity nighttime environments.
LZ2 – Moderate Activity
Areas
2700 K 0.10 fc Mixed residential, office, civic,
institutional, and moderate
commercial areas.
LZ3 – High Activity
Commercial and
Industrial
3000 K 0.30 fc Downtown, commercial corridors,
industrial, and operational areas.
a. All exterior lighting shall comply with the maximum CCT and maximum
property-line illuminance for the applicable Lighting Zone per Table 13-1-
159(2): Lighting Zone Performance Standards.
b. Where a site abuts a lower-intensity Lighting Zone, the more restrictive
maximum property- line illuminance shall apply along the shared lot line.
c. The average intensity of illumination on any portion of a lot shall not
exceed twenty-five percent (25%) above the recommended maintained
average horizontal value defined by the current ANSI/IES standard for the
applicable use and Lighting Zone, unless a higher level is required by law
or approved by the City based on a documented safety need.
d. Lighting shall be designed to prevent direct view of the light source from
adjacent residential properties, natural areas, and public rights-of-way.
6) Lighting Fixture Requirements.
a. Shielding and Aiming. All exterior lighting fixtures, including, but not
limited to, wall-mounted, pole-mounted, bollard, canopy, or otherwise
installed, are prohibited to be up lit and shall be installed such that the
bottom luminous surface is level and parallel to the ground. Light fixtures
emitting less than 500 lumens are exempt from this requirement but shall
be aimed at minimizing glare, light trespass, and sky glow.
b. CCT - Adjustable Lighting Fixtures. All permanently installed exterior
lighting shall comply with the maximum CCT for the applicable Lighting
Zone. Where light fixtures are CCT- adjustable, they shall be limited,
6
locked, or programmed not operate above 3000 K, except where a higher
CCT is specifically approved under this subsection.
c. Controls and Hours of Operation.
1. Any nonresidential land use shall extinguish exterior façade,
landscape, display, and decorative lighting within one (1) hour after
closing and shall not energize such lighting earlier than one (1) hour
before opening.
2. All other exterior lighting on nonresidential properties shall be reduced
in power by at least fifty percent (50%) or extinguished during nighttime
curfew using timers, scheduling controls, motion sensors, occupancy
sensors, or other adaptive controls.
3. Exemptions from these control requirements may be granted for
covered vehicle entrances or exits, parking structures, emergency
lighting as determined by police, fire, EMS, or public works, and
lighting required by law.
d. Flashing, Flickering and Other and/or Lighting. Flashing, flickering,
moving, searchlight, beacon, or otherwise distracting lighting is prohibited
except as required for traffic control, emergency signaling, or other lawful
public safety functions.
7) Specialty Lighting.
a. Security Lighting. Security lighting intended to illuminate fence lines,
property lines, loading areas, or other perimeter areas shall include motion
sensors or adaptive controls and shall be designed to remain off or
dimmed unless triggered. Light fixtures activated by motion detection shall
automatically turn off or return to their dimmed state no more than five (5)
minutes after activity is no longer detected.
b. Sports and Recreational Lighting. Exterior lighting for sports fields and
similar recreational facilities shall be designed to minimize glare, sky glow,
and light trespass. Lighting shall not exceed ten percent (10%) above the
maintained light levels recommended by the applicable ANSI/IES standard
for the specific sport and class of play and CCT shall not exceed 5700K.
Sports and recreational lighting shall be aimed and shielded to confine
direct light to the playing surface and immediately adjacent spectator
areas, shall comply with the applicable property-line illumination limits for
the assigned Lighting Zone, and shall be extinguished no later than thirty
(30) minutes after the end of play or 11:00 p.m., whichever occurs first,
unless otherwise authorized by a special event permit issued by the City.
c. Seasonal and String Lighting.
7
1. Seasonal lighting and lighting fixtures that have no bulbs that exceed a
factory-rates light output of 500 lumens shall be exempt from Section
6, Lighting Zone Performance Standards and Section 7, Lighting
Fixture Requirements.
2. String lighting, also known as festoon string lighting, where no
individual bulb or LED module emits more than fifty (50) lumens, and
the lumen density of the string is no greater than twenty-five (25)
lumens per foot. If greater than fifty (50) lumens, a hood shall be
installed for each bulb or LED module to ensure no uplighting.
3. Seasonal lighting shall not interfere with the safe movement or motor
vehicles or create a dangerous glare condition on adjacent roadways
or properties.
4. Seasonal lighting shall be maintained and not constitute a dangerous
situation or fire hazard.
5. Seasonal lighting must be extinguished during nighttime curfew
(Section 11-5-1).
Zoning Text Amendment Findings
A determination is required to ensure that a Zoning Text Amendment is in harmony
with the recommendations of the City of Verona’s Comprehensive Master Plan by
answering the following questions posed in Section 13-1-215 of the Zoning
Ordinance.
a. How does the proposed text amendment further the purposes of this title
and the general article in which the amendment is proposed to be located
as outlined in section 13-1-5?
The proposed text amendment supports the Plan as it is the first step in establishing
a way to minimize light pollution and gravitate to dark skies.
b. How does the proposed text amendment further the purposes of the
specific section in which the amendment is proposed to be located?
The proposed text amendment repeals and recreates the lighting ordinance for a
greater understanding on how to implement the lighting requirements as well as
definitions to support new language introduced through this amendment.
c. Which of the following factors has arisen that are not properly addressed
in the current zoning text:
8
1. The provisions of this chapter should be brought into conformity with
the Comprehensive Plan (if a factor related to the proposed
amendment, note pertinent portions of the Comprehensive Plan);
2. A change has occurred in the land market, or other factors have
arisen which require a new form of development, a new type of land
use, or a new procedure to meet said change(s);
3. New methods of development or providing infrastructure make it
necessary to alter this chapter to meet these new factors;
4. If the proposed text amendment is concerned with the provisions of
articles C and/or D: How does the proposed amendment maintain the
desired overall consistency of land uses, land use intensities, and
land use impacts within the pertinent zoning districts?
Staff has requested this amendment due to improvements in technology that allow
lighting levels to fluctuate as needed. The Plan was updated and now supports
policies to support dark skies and minimize light pollution.
Staff Comments:
In general, Staff is supportive of the proposed amended lighting ordinance. The
proposal is a first step in beginning to migrate to becoming dark skies compliant in
the future. New construction will meet these requirements immediately; however,
existing lighting is exempt and those properties will comply when lighting fixtures are
replaced. Education is key for implementation of the ordinance and transitioning
existing lighting fixtures to compliant fixtures especially for single-family and
duplexes.
Recommendation:
Staff recommends the Plan Commission recommend the Common Council approve
the zoning text amendment for Sections 13-1-44 Definitions - B, 13-1-54 Definitions
– L, 13-1-61 Definitions – S, 13-1-63 Definitions -U, and 13-1-159 – Performance
Standards.
9
Attachment A: Original Language
Sec. 13-1-159 - Performance Standards.
(a) Exterior Lighting Standards.
1. Purpose. The purpose of this subsection is to regulate the spill-over of light
and glare on operators of motor vehicles, pedestrians, and land uses in the
vicinity of a light source in order to promote transportation safety and to
prevent the creation of nuisances.
2. Applicability. The requirements of this subsection apply to all private exterior
lighting within the jurisdiction of this chapter, except for lighting within public
rights-of-way and/or lighting located on public property.
3. Requirements.
a. Fixtures. Light sources shall be full cutoff fixtures with the light source
fully shielded and directed downwards.
b. Intensity of Illumination. In no instance shall the amount of illumination
attributable to exterior lighting, as measured at the property line, exceed
0.40 footcandles above ambient lighting conditions on a cloudless night.
c. Location. Light fixtures shall not be located within required landscape
areas.
d. Flashing, Flickering and Other Distracting Lighting. Flashing,
flickering, and/or lighting which may distract motorists are prohibited.
e. Minimum and Maximum Lighting Standards. All areas designated on
required site plans for pedestrian circulation, vehicular or bicycle parking,
loading, or circulation and used for any such purpose after sunset shall
provide artificial illumination in such areas at a minimum intensity of 0.4
footcandles and at a maximum intensity of ten (10) footcandles during
hours of operation. Lighting shall be dimmed to fifty (50) percent after
hours of operation. Dimming can be provided by timer or motion sensors.
f. Special Events Lighting. Any temporary use using exterior lighting which
is not in complete compliance with the requirements of this subsection
shall secure a temporary use permit (see section 13-1-218).
g. Wall Mounted Accent Lighting. Wall mounted accent lighting shall be
integrated with the architectural character of the building and shall use
low-luminosity lamps, with two thousand (2,000) source lumens or less.
10
The illumination on any vertical surface shall not exceed one-half (0.5)
maintained footcandle and shall not spill over roof lines or building edges.
Epic Systems Corporation
Planning Report
City of Verona
Plan Commission 11-4-2026
Site Plan
Property Location: 1979 Milky Way
Property Owner: Epic Systems Corporation
1979 Milky Way
Verona, WI 53593
Applicant: Same
Existing Zoning: Suburban Industrial
Existing Land Use: Temporary parking lots
Proposed Land Use: Permanent and temporary parking lots
Figure 1 – Location Map
CTH PD
Summary: The applicant is requesting a site plan review for one (1) permanent and
one (1) temporary parking lots located at 1979 Milky Way.
Northern Lights Rd.
Note: North Lot, permanent lot, is depicted in yellow and Farmyard Lot, temporary lot, is depicted in teal.
Site Plan Review and Temporary Use Permit
Epic Systems Corporation
2
Background:
Below is a summary of Epic’s office campus construction and expansion in the City:
• June 2003 – Campus 1 – City grants Epic a conditional use permit (CUP), group
development, to construct Epic’s corporate headquarters with multiple buildings
and structured parking.
• February 2005 – CUP amended to allow construction of the “Learning Center”.
• March 2007 – Campus 2 – CUP amendment to construct four (4) office buildings
and structured parking.
• March 2011 – Deep Space Auditorium – CUP amended to allow for the
construction of an 11,000 – 13,000 seat auditorium.
• December 2011 – Campus 3 – CUP amendment to allow for the construction of
the Farm Campus, containing three (3) office buildings and structured parking.
• May 2013 – Campus 4 – CUP amendment to allow for the construction of a
1,500 vehicle underground parking structure.
• September 2013 – Food Service Building – CUP amendment to allow for the
construction of a 64,000 square foot food service building.
• November 2013 – Campus 4 – CUP amendment to allow for the construction of
five (5) office buildings containing 1,580 offices known as the Wizards Academy.
• February 2014 – Food Service Building – Site plan amendment reducing the
size of the food service building to 48,250 square feet.
• May 2014 – Campus 5 – CUP amendment to allow for the construction of the
Campus 5 underground parking structure.
• February 2015 – Campus 5 – CUP amendment to allow for the construction of
five (5) office buildings containing 1,600 new offices.
• January 2020 – Campus 5 – Phase 2 – CUP amendment and site plan to allow
for the construction of two (2) office buildings (Mystery and original location of
Castaway) containing 700 new offices.
• April 2021 – Campus 5 – Phase 3 – CUP amendment and site plan to allow for
the construction of one (1) office building containing 350 offices called Castaway.
• August 2021 – Campus 5 - Temporary contractor office – Site plan to allow for
the temporary contractor building to be relocated in Campus 5.
• April 2022 – Campus 5 – Phase 4 – Site plan to allow for the construction of one
(1) office building, a private restaurant, and bakery.
• January 2023 – Campus 4 expansion – Site plan to allow for the construction of
two (2) office buildings (Creatures and Guilds).
• April 2023 – Temporary Parking Lots – Site plan to allow for the construction of
two (2) temporary parking lots called North Lot of approximately 676 parking
stalls and Farmyard Lot of approximately 376 parking stalls.
Site Plan Review and Temporary Use Permit
Epic Systems Corporation
3
• May 2023 – Temporary Parking Lot – Site plan to allow for the construction of
approximately 1,012 parking stalls in a temporary west parking lot.
• June 2023 – Campus 6 – Site plan to allow for the construction of an
underground parking structure containing 2,050 parking stalls.
• April 2024 – Campus 6 – Site plan to allow for the construction of three (3) office
buildings and one (1) food service building (Elvendell, Azland, Floating Forest,
and Underhill).
• May 2024 – Final plat to create two (2) lots.
• October 2024 – Site plan for a tunnel connecting Campus 4 to Campus 6.
• January 2025 – Site plan and site plan amendment to allow for the construction
of two (2) new office buildings (Longago FarAway and Dragonfell) and relocate
three (3) office buildings and one (1) food service building (Elvendell, Azland,
Floating Forest, and Underhill).
• March 2025 – Site plan to allow for the construction of one (1) buried lecture
room, referred to as Deep Space Extension (DSX) for approximately 750 people.
• June 2025 – Site plan for an addition onto an existing storage building (MB-44).
• March 2026 – Final plat to create five (5) lots and four (4) outlots.
• May 2026 – Campus 6 – Site plan amendment to relocate a building and change
building materials.
Project Description:
As Epic’s campus continues to grow, shuffling of employees and parking locations
continue to occur with Campus 6 under construction. The Applicant was approved in
April 2023 for a northern temporary parking lot (North Lot) of 676 parking stalls in what
was originally the construction laydown and staging area and a southern parking lot
(Farmyard) of 376 parking stalls on top of an existing parking garage that originally
contained the soccer and recreation field. The goal of these lots were to be utilized
starting in the summer of 2023 until the end of 2026 for a total of three (3) years at
which point other permanent underground parking garages will be completed. While the
temporary parking lots were approved, the following conditions were required:
1. The parking lots may be utilized until December 31, 2026.
2. If the lots are not vacated and removed by December 31, 2026, all site plan
requirements for a permanent parking lot shall be installed by the Applicant no
later than December 31, 2026. These items include landscaping, parking lot
islands, lighting, and charging stations.
Blackhole parking facility is opened but will not be at full capacity “until four (4)
additional office buildings are construct on Campus 6” (Narrative, p. 1). The Applicant is
requesting a site plan review to extend the farmyard temporary parking lot beyond 2026
to 2031 and the north lot to become a permanent surface parking lot.
Site Plan Review and Temporary Use Permit
Epic Systems Corporation
4
Planning Review:
Bulk Requirements:
Staff has no concerns with the location or setbacks as these are located on the Epic
campus.
Parking/Access:
Access to the North Lot is from Hubble Road and access to the Farmyard is from Epic
Lane. The North Lot was paved and has stripped parking stalls. Access to campus from
the North Lot is from an internal bus or shuttle service for employees. The Farmyard Lot
has standard concrete with stripped parking stalls since the earthwork was removed
from the top of the existing parking garage.
Table 1 contains information about the number and location of parking stalls for the
entire campus with the two (2) temporary parking lots highlighted in yellow.
Table 1: Parking Stalls
Campus 1
Zodiac Ramp 1,215
Zodiac Ramp (exposed) 175
Surface 20
Campus 2
Yoda Ramp 2,025
Surface 5
Campus 3
Farmyard Ramp 1,070
Surface 7
Temporary Farmyard Lot 376
Campus 4
Abyss Ramp 2,065
Surface 13
Temporary North Lot 676
Temporary West Lot
(no longer used)
1,012
Campus 5
Jabberwocky Ramp 3,076
Surface 10
Campus 6
Blackhole Ramp 2,050
Total Parking 12,783
Landscaping:
With all site plans, a landscaping plan is submitted for review by Staff. Epic typically
exceeds the landscaping requirements with more plantings that is required on their
campus. In this case, Staff will coordinate and review a landscaping plan when it is
submitted for the North parking lot as Staff is requiring landscaping around the
Site Plan Review and Temporary Use Permit
Epic Systems Corporation
5
perimeter of the parking lot. Because the lot will be used for bus parking, interior parking
lot landscaping will not be required. If the parking lot was not built and did not support
buses, Staff would require interior parking lot landscaping, including parking lot islands,
per the Zoning Ordinance.
As the Farmyard parking lot will remain temporary, Staff is not recommending
installation of landscaping on the parking garage structure as this would be covered
after the temporary parking lot is removed.
Lighting:
The Applicant installed eighteen (18) twenty-two (22) foot tall light poles for the North
Lot to meet safe work requirements during hours of operation. Staff has no concerns
regarding lighting as property lines are far from the proposed buildings, which is where
lighting levels are analyzed.
Drainage/Stormwater:
Drainage and stormwater were reviewed as part of the original site plan review and is
still met.
Site Plan Review:
The Plan Commission as part of their Site Plan review shall take into account the
following per Section 13-1-220(f) in the Zoning Ordinance:
(1) The basic intent of the Comprehensive Master Plan and Zoning Ordinance
to ensure attractive, efficient, and appropriate development of land in the
community;
The Comprehensive Plan shows the Epic property as an office campus. The
temporary parking lots are an efficient use of the land as parking lots are either
on an existing structure or created in a former construction yard. These lots
continue to support the overall growth and staging for employee parking until the
lots and office buildings can be occupied. The North Lot now functions as a
permanent parking lot to stage event buses and emergency response
coordination. The Comprehensive Plan continues to support opportunities for
transit.
(2) Whether the site plan application ensure particularly that every reasonable
step has been taken to avoid depreciating effects on surrounding property
and the natural environment;
The North Lot utilized a construction laydown and staging area that is out of sight
from the public. The Farmyard Lot exists was unearthed to accommodate the
additional parking needed.
Site Plan Review and Temporary Use Permit
Epic Systems Corporation
6
(3) Whether the site plan application ensures that adequate public utilities and
public services are being provided.
There are public utilities and public services being provided to this area.
Staff Comments:
Staff are supportive of the North parking lot becoming a permanent parking lot with the
addition of perimeter landscaping as this is a staging area for buses. Staff has some
concerns with the timeline for removal of the Farmyard temporary parking lot. The
Applicant is requesting extending the deadline for five (5) years to 2031. The original
approval was for three (3) years and Staff are supportive of the temporary parking lot for
another three (3) years to 2029.
Recommendation:
Staff recommends the following Plan Commission actions:
1. Approve the site plan for the permanent North parking lot with staff approval of a
landscaping plan.
2. Approve the site plan and temporary use permit for the Farmyard parking lot with
the following condition:
a. The parking lot may be utilized until December 31, 2029.
b. If the lot is not vacated and removed by December 31, 2029, all site plan
requirements for a permanent parking lot shall be installed by the
Applicant no later than December 31, 2029. These items include
landscaping, parking lot islands, lighting, and charging stations.
Prepared by: Katherine Holt
Community Development Specialist
Submitted by: Lucas Sivertsen, AICP
Director of Planning and Development
Epic Extension Request for Parking Lots Project Description Epic is requesting the conditional approval status of the Farmyard and Overflow lots be extended. Per current City of Verona approvals, the lots may be utilized until 12/31/26 unless upgraded to meet additional requirements such as landscaping, islands, lighting, and charging stations. Farmyard Lot The initial proposed lifespan of the temporary Farmyard lot was approximately 3 years, starting in early summer 2023 and remaining in use until the next underground parking structure, now formally known as Black Hole Parking Facility, occupies in 2026. While Black Hole is now open, its full capacity will not be utilized until 4 additional office buildings are constructed on Campus 6. Thus, we ask the temporary Farmyard lot remain in service to continue to provide 1,052 additional stalls until Campus 6 is further developed. Epic is requesting 5 additional years on the Farmyard parking lot to get through the construction of the Rogue Planet and Dragonfell (Occupy in 2028) and 2 future buildings that are under design. Occupy date for future Campus 6 buildings is undetermined but expected in 2030 and 2031 Overflow Lot The Overflow lot function has evolved over time. Originally, it was intended to serve as extra surface parking for employees while the parking structures were being completed. Since then, this lot has been used for large event bus staging and emergency response coordination and training. Other uses involve WDOT inspections of buses. Due to the large vehicle size and volume, upgrading this lot with landscape islands would limit the current use. Epic would like to make the Overflow Lot in permanent in its current configuration to support Events, Bus Staging and public safety uses. To compensate for not installing vegetated curb islands, additional perimeter landscaping has been discussed with City staff beyond the already installed screening berms and general remoteness of this lot from public view. We suggest Staff Approval of a landscape plan to be produced this winter with a staged installation over the next two years. Stormwater Considerations: Farmyard Lot: Two bio-retention trenches were built to serve as stormwater management for the farmyard lot. Two downstream detention ponds existed before constructions and contribute to peak flow treatment. The bio-retention facilities were as-built in February of 2025 and the plan has been accepted by AECOM. The bio-retention trench will continue to serve as stormwater management until the parking lot is removed. Overflow Lot: A combination of two wet ponds and one bio-retention facility was built to serve as stormwater management for the North Lot. The facilities were as-built in June of 2023 and the plan has been accepted by AECOM. The wet ponds and bio-retention facility will continue to serve as stormwater management.
Ardent Glen – Third Addition
Planning Report
City of Verona
Plan Commission 11-4-2026
Final Plat
Property Location: north of 2905 and 2947 Shady Oak Lane
Property Owner: VH Ardent Glen, LLC
6801 South Towne Drive
Madison, WI 53713
Applicant: D’Onofrio, Kottke, & Associates, Inc. – Dan Day
7530 Westward Way
Madison, WI 53717
Existing Land Use: Vacant
Proposed Land Use: Single-family and mixed residential development
Existing Zoning: Mixed Residential (MR), Public Institutional (PI), and
Planned Development Overlay
Proposed Zoning: Same
Figure 1 – Location Map
Summary: The Applicant is proposing to create 75 single-family and twin home lots
and five (5) outlots north of CTH PD and west of Shady Oak Lane.
Shady Oak Lane
CTH PD
Final Plat
Ardent Glen – Third Addition
2
Site Description:
VH Ardent Glen LLC (“Applicant”) is requesting a final plat to develop approximately 75
lots and five (5) outlots to be located north of 2905 and 2947 Shady Oak Lane and west
of Shady Oak Lane (“Property”). This is another plat for Ardent Glen Subdivision called
Ardent Glen Third Addition. Additional plats for Ardent Glen subdivision would go before
the Plan Commission and Common Council at a later date.
Background:
• May 2021 – An initial plan to develop approximately 142-acres of land with
seventy-four (74) carriage lane accessed single-family homes, 218 street
accessed single-family homes, sixteen (16) twin homes, and ninety-two (92) twin
homes.
• November 2021 - Annexed 147.988-acres of land into the City of Verona.
• September 29, 2022 - WDNR approved the proposed urban service area
amendment for the Ardent Glen development, and other lands.
• December of 2022 – Approved the following plans with conditions to be effective
upon the execution of a development agreement.
o Preliminary and final planned development for the Ardent Glen subdivision
with the following exemptions and condition:
The minimum lot area is 2,550 square feet;
The minimum lot width is thirty-one (31) feet for alleys;
The minimum corner setback is ten (10) feet instead of twenty (20)
feet for all products;
The minimum rear setback is two (2) feet instead of twenty (20) feet
for alley accessed products;
The minimum pavement setback is two (2) feet instead of five (5)
feet for all products;
The maximum lot coverage is eighty (80) percent for alley accessed
homes and seventy (70) percent for alley accessed single family
and street accessed haven homes; and
o Zoning map amendment to rezone lots 1-406 to Mixed Residential (MR)
and outlots 1-25 to Public Institutional (PI).
o Preliminary plat to create 406-lots and 25-outlots with the following
conditions:
The final plat shall have private alleys labeled as fire lanes.
While not explicitly called out in the staff report for exemptions, the following
exemptions were also understood to be allowed and were included in their
Application packet.
o Garage setback:
Street facing garages are twenty-two (22) feet (minimum front yard
setback);
Final Plat
Ardent Glen – Third Addition
3
Side entry garages are twenty (20) feet (minimum front yard
setback);
Ten (10) foot minimum side yard setback (non-garage door side
yard);
Street facing garages must be setback a minimum of two (2) feet
from the front façade of the house.
o Garage setback:
Terraces, steps, uncovered and covered front porches, decks,
stoops, or similar appurtenances to residential buildings which do
not extend above the flood level of the adjacent building entrance
may encroach a maximum of six (6) feet into the front yard setback.
At grade patios may encroach up to the paved side yard setback
allowance.
Decks may encroach up to ten (10) feet into rear yard setback.
Corner lot porches, and bay windows may not encroach the vision
triangle.
Garden walls or fences shall be no more than four (4) feet in height
and will require approval by the Architectural Control Committee.
Walls and fences located within the vision triangles shall not
exceed thirty (30) inches in height.
• May 2023 - Phase 1 final plat created 102 single-family and twin home parcels
and 12 outlots with the following conditions:
o The final plat shall have private alleys labeled as fire lanes.
o The final plat shall become effective upon approval of the floodplain
modifications by the State and federal agencies.
• November 2023 - Administratively created two (2) new outlots owned by the
Homeowners Association.
• November 2023 – Final plat was recorded and included the two (2)
administratively approved outlots.
• April 2025 – First Addition to Ardent Glen final plat created fifty-four (54) single-
family and twin home lots and six (6) outlots.
• February 2026 – Preliminary and final planned development amendment and a
preliminary plat modified 406 lots to create 425-lots and 25-oulots with the
following conditions:
o Minimum lot area for the MR zone of 6,000 square feet to 2,550 square
feet.
o Minimum lot width from fifty (50)-feet to thirty-one (31)-feet for lots where
garages are accessed from an alley.
o Minimum corner side yard setback from twenty (20)-feet to ten (10)-feet.
o Minimum rear yard setback twenty (20)-feet to two (2)-feet for lots where
garages are accessed from an alley.
o Minimum paved surface setback from five (5) feet to two (2) feet.
Final Plat
Ardent Glen – Third Addition
4
o Maximum lot coverage from fifty (50%) percent to eighty (80%) percent.
o Minimum street right-of-way garage setback from twenty-five (25) feet to
twenty (20) feet.
o Minimum street right-of-way garage setback from twenty-five (25) feet to
ten (10) feet for garages accessed from alley.
o Minimum front yard patio, steps, uncovered and covered porches, decks,
stoops, or similar appurtenances which do not extend above the floor level
of the adjacent building entrance from twenty (20) feet to fourteen (14)
feet.
o Minimum side yard patio setback from five (5) feet to two (2) feet.
o Minimum rear yard deck setback from twenty (20) feet to ten (10) feet for
lots without alley access.
o The preliminary and final planned development shall become effective
upon the execution of a development agreement.
o The preliminary and final planned development shall be subject to the
City’s adopted stormwater management requirements.
• August 2026 – Second Addition to Ardent Glen final plat created eighty (80)
single-family and twin home lots and five (5) outlots.
Planning Review:
Lots:
The Applicant is proposing seventy-five (75)
single-family and twin home lots with a
Mixed Residential (MR) zoning district
designation and five (5) outlots with a Public
Institutional (PI) zoning district designation.
The smallest lot will be 3,450 square feet
while the largest lot will be 16,588 square
feet.
Connectivity:
The Applicant is proposing to extend Spring
Garden Street to Shady Oak Lane
completing the east-west connection and
second access point into Ardent Glen. Other
roadways and alleys will be constructed as
part of this plat. Outlot 30 has a note that
this can be used as a future trail connection
from Shady Oak Lane to Legend Way. Staff
have no concerns with the road
configuration.
Outlots:
The Applicant is proposing one (1) outlot for
private open space, one (1) outlot for
Figure 2 - Outline of Second Addition plat for the Ardent Glen Subdivision
Final Plat
Ardent Glen – Third Addition
5
sanitary sewer and a trail, and one (1) outlot to be used for future development as part
of a future phased final plat. While the park is planned to remain private and not be
dedicated to the public, it received credit for parkland and the final park design would
require approval from the Park Board. The remaining two (2) outlots contain private
alleys. The private alleys will allow access to garages from the rear of the home. These
private alleys are labeled as fire lanes as this allows the City to tow vehicles if the
vehicles are parked in the alley.
Recommendation:
Staff recommend the Plan Commission recommend that the Common Council approve
the Final Plat for the Third Addition to Ardent Glen to create seventy-five (75) single-
family and twin home lots and five (5) outlots.
Prepared by: Katherine Holt
Community Development Specialist
Submitted by: Lucas Sivertsen, AICP
Director of Planning and Development
October 1, 2026 Lucas Sivertsen City of Verona 111 Lincoln Street Verona, WI 53593 Re: Third Addition Ardent Glen Final Plat Submittal Dear Lucas: On behalf of Veridian Homes, we are pleased to submit the information necessary for the review and approval of the final plat for the Third Addition to Ardent Glen. The following documents are being supplied digitally only at this time except the check will be hand delivered to City Hall. Hard copies will be provided prior to the Plan Commission meeting if necessary. Enclosed please find the following related to final plat submittal: Final Plat Application Form Current Master Plan color graphic Current Master Plan with 3rd Addition plat boundary shown Check in the amount of $2,300 for the review of the application (hand delivered) I will email a link for the above files. Engineering documents including the updated Shady Oak Design Report, updated Storm Water Management Report and updated phase 5 engineering plans and documents are being submitted directly to AECOM. Please call if you have any questions. Sincerely, Daniel N. Day, P.E. cc: Matt Brink, Veridian Homes, LLC (via email) Brian Munson, Vandewalle Associates, Inc (via email) U:\User\2607112\01_Admin\Submittals\2026.10.01 City Final Plat\AG 3rd Add Final Plat Submittal.docx
140 and 142 Jenna Drive
Planning Report
City of Verona
Plan Commission 11-4-2026
Certified Survey Map
Property Location: 140 and 142 Jenna Drive
Property Owner: Robert and Kelly Gilboy
7608 Marsh View Road
Verona, WI 53593
Applicant: Same
Existing Zoning: Mixed-Residential (MR)
Existing Land Use: Duplex
Proposed Land Use: Same
Figure 1 - Location Map
Summary: The applicant has submitted a certified survey map (CSM) to split lot 58
of Westridge Estates located at 140 and 142 Jenna Drive into two (2)
lots.
Westward Dr.
Edward Street
140 and 142 Jenna Drive
Certified Survey Map
2
CSM Review:
The Applicant is proposing a
CSM to split lot 58 in Westridge
Estates located at 140 and 142
Jenna Drive (Figure 1) into two
(2) lots; lots 1 and 2 as depicted
in Figure 2. The proposed land
division will facilitate separate
ownership of each unit of an
existing duplex which is defined
by the City of Verona Zoning
Ordinance as a “row or
structure of up to four (4)
attached, single-family,
dwellings joined to one another
at one (1) or more sides by a
party wall or walls. Each
dwelling has a dedicated
exterior entrance”. The existing
parcel is zoned Mixed
Residential (MR), which allows
single-family dwellings,
duplex/townhome dwellings,
and multiunit buildings. The
building is built and the
proposed CSM will not change the structure.
The MR zoning district allows duplexes as long as they meet the following requirements
in Section 13-1-122(e):
(1) The main entrances to a duplex/ townhome are encouraged to face the primary
street.
(2) A minimum of one (1) of the parking spaces, as required in Section 13-1-151 of
this Zoning Ordinance, shall be provided in an attached or detached garage.
(3) Attached garages are encouraged to be located on rear façades. If attached
garages are located on the primary façade they shall:
a. Be setback a minimum of twenty-five (25) feet from the street right-of-way;
and
b. Be recessed from the primary front façade (excluding porches) of the
duplex/ town home a minimum of one (1) foot.
(4) Exterior building materials shall be time- and weather- tested materials and
techniques such as but not limited to masonry, stone veneer systems, stucco,
precast panels with inlaid or stamped brick texture.
The proposed CSM is an interior lot. The total combined square footage is 13,533
square feet with each proposed lot meeting the lot area requirements. The attached
garage does not meet the zoning requirements, but the residential building was
Figure 2 - Proposed CSM
140 and 142 Jenna Drive
Certified Survey Map
3
developed well before the specific use standards were created. The proposed use will
not change; therefore, the use standards are not a factor in determining the ability of a
lot to be divided. Staff have no concerns.
Additional requirements were reviewed for previous duplexes (formerly called twin
homes) to include the following:
• A minimum one (1)-hour fire separation must exist between the units and
• Individual sanitary sewer and water service must exist between the units as well
as electrical and gas.
Shared Wall Agreement:
The two (2) units within the building may be owned by separate owners. Similar to other
previously approved CSM’s for duplexes, Staff recommends a shared wall agreement
be recorded against each unit as a condition of approval. The Applicant has included a
draft agreement in the Plan Commission packet.
Recommendation:
Staff recommend the Plan Commission recommend that the Common Council approve
the certified survey map to split lot 58 of Westridge Estates addressed as 140 and 142
Jenna Drive into two (2) lots with the following condition:
a. A shared wall agreement shall be recorded with the Dane County Register of
Deeds.
Prepared by: Katherine Holt
Community Development Specialist
Submitted by: Lucas Sivertsen, AICP
Director of Planning and Development
1694 Range Trail
Planning Report
City of Verona
Plan Commission 11-4-2026
Certified Survey Map
Property Location: 1694 Range Trail
Property Owner: Gary Ishmael
1694 Range Trail
Verona, WI 53593
Applicant: Same
Existing Zoning: Rural Residential (RR-8) – Town of Verona
Existing Land Use: Single-family home
Proposed Land Use: Same
Figure 1 – Location Map
Summary: The Applicant has submitted a certified survey map (CSM) to split one (1)
lot into two (2) lots located at 1694 Range Trail.
Range Trail
Black Cherry Court
CTH PB
Sunset Drive
Certified Survey Map
1694 Range Trail
2
CSM Review:
The Applicant is proposing a certified survey map (CSM) to split Lot 1 into two (2) lots
located at 1694 Range Trail (“Property”) in the Town of Verona. The CSM is being
reviewed as part of extraterritorial platting. Extraterritorial platting authority is a state
statute that provides Cities and Villages the authority to review land divisions that are
within a mile and a half (1 ½ mile) radius around those municipalities. While the land is
within the Town of Verona, the Property is within the City’s extraterritorial platting
jurisdiction.
The Property is a total of 9.2 acres and zoned Rural Residential (RR-8) in the Town of
Verona, which allows one (1) single family home per a minimum of eight (8) acres. The
Property is subject to Dane County Zoning regulations. While the City has extraterritorial
plat authority it does not have extraterritorial zoning authority. The Applicant is
requesting a zoning map amendment through Dane County to change the zoning from
RR-8 to RR-4, which would allow one (1) single family home per four (4) acres.
Lot 1 will consist of approximately 4.01 acres with an existing single-family home and
existing driveway from Range Trail. Lot 2 will consist of approximately 4.82 acres with
access from Black Cherry Court.
As part of this CSM, the Applicant is dedicating land towards right-of-way for Range
Trail, but no additional right-of-way is needed for Black Cherry Court. The City of
Verona Comprehensive Plan study boundary is bound by the northern side of Sunset
Drive. This Property is located south of Sunset Drive and outside of the study boundary.
Recommendation:
Staff recommend the Plan Commission recommend that the Common Council approve
the certified survey map to create two (2) lots from the existing one (1) lot located 1694
Range Trail.
Prepared by: Katherine Holt
Community Development Specialist
Submitted by: Lucas Sivertsen, AICP
Director of Planning and Development
Memorandum
To: Plan Commission
From: Katherine Holt, Community Development Specialist
Date: November 4, 2026
Re: Urban Service Area amendment
Staff are requesting a recommendation from the Plan Commission to the Common
Council to amend the Verona Urban Service Area (USA) due to a future development
project. If approved by the Common Council, a detailed document regarding water and
land use would be provided to the Capital Area Regional Plan Commission (CARPC) to
make a recommendation to the Department of Natural Resources (DNR) as to whether
the area can be added to the Verona USA. The DNR makes the final decision. This is
the first step in a lengthy process and does not lock the City into any land use proposals
as the attachment is a conceptual plan. The site plans would still have to go through the
development review process including annexation, rezoning, platting and site plan
review.
6500 Shady Bend Road:
Staff are requesting to add approximately forty (40)-acres of land located at 6500 Shady
Bend Road in the Town of Verona to the Verona USA per the attachment. In October of
2026, the Common Council approved a contract to employ Vandewalle and Associates,
Inc. to prepare an USA amendment application that would be provided to CARPC. The
goal of the USA amendment is to accommodate a proposed public works facility and the
extension of public water and sanitary sewer service. The USA amendment process can
typically take up to six (6) months to prepare an application, present the information to
CARPC, and have DNR make a final recommendation.
At this time, the City is in discussions with the property owner to purchase 6500 Shady
Bend Road to locate the public works facility on this property. The property would need
to be annexed into the City of Verona to provide public water and sanitary sewer service
as well as a site plan to approve any type of development on this property. An
expansion of the USA into the subject area would be required to permit any extension of
sanitary sewer necessary for development as indicated in the City’s Comprehensive
Plan.
Recommendation:
Staff recommends the Plan Commission recommend the Common Council approve a
resolution to add approximately forty (40)-acres of land located at 6500 Shady Bend
Road to the City’s USA.
Urban Service Area Amendment
https://www.veronawi.gov/DocumentCenter/View/6216/Department-of-Public-Works-Garage-Facility-Program-Update-03-23-
2026?bidId=
Source: City of Verona website. First collected Nov 1, 2026.