RecordWell Data

Plan Commission Agenda & Packet (PDF)

City of Plymouth · Sheboygan County · meeting of Nov 5, 2026 · Agenda packets

Open the original document More from City of Plymouth

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

City of Plymouth Plan Commission Mem bers: Please notify us if you are unable to attend the meeting. Cha irman; Mayor Don Pohlman Mem bers: Ron Nicolaus (Vice Chairman) Angie Matzdorf Jane Meyer Jeremy Schellin John Wyatt Justin Schmitz The Ci ty of Plymouth Plan Commission will have a meeting on Thursday, November 5, 2026 at 6:00 PM in Room 305, City Hall, 128 Smith St, Plymouth, Wisconsin. The agenda wi ll be as follows: 1.) Call to Order & Roll Call 2.) Approval of Minutes from October 1, 2026 3.) S ite Plan Seeking Approval: 2615 Eastern Avenue, LLC (dba Carbliss Headquarters) for the alteration of an existing parking lot, as well as the alteration of the existing building in order to construct the new Carbliss Headquarters and restaurant. Excel (enclosure) 4.) P ublic Hearing: A public hearing to take comment and provide possible action on a conditional use permit application for the following: a. 2615 E astern Avenue, LLC (dba Carbliss Headquarters) regarding a conditional use permit (CUP) application, seeking relief from Sec. 13-1-106(a) of the City of Plymouth Code of Ordinances in order to construct three (3) digital display board signs totaling approximately 594 square feet to be located at 2615 Eastern Avenue. Excel (enclosure) 5.) C ommunication – Letters, E-mails, or reports Related to the Plan Commission (Chairman, Secretary, Plan Commission Members, City of Plymouth Staff/Alderpersons) 6.) A djournment It is possible that members of and possibly a quorum of members of other governmental bodies of the municipality may be in attendance at the above stated meeting to gather information. No action will be taken by any governmental body at the above stated meeting other than the governmental body specifically referred to above in this notice. Please note that, upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through appropriate aids and services. For additional information or to request this service, contact the City of Plymouth, located at Plymouth City Hall at 128 Smith Street, Plymouth, WI or call 920-893-1271. Page 1 of 36 City of Plymouth Plan Commission UNOFFICIAL MINUTES Mayor Pohlman called the meeting to order at 6:00 PM on October 1, 2026. The following members were present: Angie Matzdorf, Ron Nicolaus, Jeremy Schmitz, John Wyatt, Jane Meyer, Justin Schellin. Also present: Assistant City Administrator/Community Development Director Jack Johnston, City Administrator/Utilities Manager Tim Blakeslee 1.) Call to Order & Roll Call: Mayor Pohlman called the meeting to order at 6:00 pm. The meeting began with a roll call of the Plan Commission. 2.) Approval of Minutes from September 3, 2026 Motion was made by Schmitz/Wyatt to approve the minutes. Upon the call of the roll, all voted aye. Motion carried. 3.) Site Plan Approval; 4200 County Road PP, SFC-Plymouth LLC (Sartori Cheese), for the alteration of an existing parking lot in the H-I Heavy Industrial zoning district. Wagner (enclosure) The Plan Commission approved the Sartori Cheese expansion project late last year. As part of the overall site plan approval, the Plan Commission approved the building as well as the associated parking and landscaping. At this time, Wagner Excavating on behalf of Sartori is coming back to the City to alter the parking lot design to add additional parking spaces from what was approved last year. Derek Wagner from Wagner Excavating was present for the meeting on behalf of Sartori. Commissioner Schellin asked if the existing drive was gravel and would remain as gravel. Assistant City Administrator Johnston confirmed this and noted gravel parking lot s and drives are permissible in the H-I district. Motion was made by Wyatt/Schmitz to approve the site plan for Sartori as presented. Upon call of the roll, all voted aye. Motion carried. 4.) Comprehensive Plan Map Amendment Resolution; from Industrial to Parks & Open Space on the Future Land Use Map; Tax Parcel 59271802310 and 59271822200 (former Plymouth Utilities building at 12 S. Milwaukee St. and pedestrian foot bridge). Johnston (enclosure) In August of 2026, Sheboygan County and the City of Plymouth finished a pedestrian bridge project over the Mullet River next to the old Plymouth Utilities building located as 12 S. Milwaukee Street. This new bridge addresses a pedestrian connection gap by connecting the downtown pedestrian trail along the Mullet all the way through Meyers Park to the south. With this project now complete, staff would like to consider future land uses along this corridor near the City’s downtown. The parcel leading up to the new trail bridge, as well as the former Utilities building at 12 S. Milwaukee Street to the south, are both designated as industrial on the City’s existing and future land use map. Staff would like to consider reclassifying both of these parcels to “Parks & Open Space” on the City’s Future Land Use Map to allow for the potential of future redevelopment and expansion of the parks and trails network in this area. This update would not restrict the current uses going on there from continuing, however, and the Existing Land Use Map would remain as “Industrial” for both of these parcels. Page 2 of 36 Motion by Nicolaus/Wyatt to approve the resolution recommending a Comprehensive Plan amendment on the Future Land Use Map; Tax Parcel 59271802310 and 59271822200 (former Plymouth Utilities building at 12 S. Milwaukee St. and pedestrian foot bridge). Upon call of the roll, all voted aye. Motion carried. 5.) Comprehensive Plan Map Amendment Resolution; 107 Plaza Lane and adjacent properties (parcel 59016218760, 59016218771, and 59016218772) seeking commercial land use designation on the Existing and Future Land Use Maps of the City of Plymouth Comprehensive Plan. Meyers Motors (enclosure) Meyer Motors on the corner of Plaza Lane and Eastern Avenue is comprised of four parcels of land. The former Wells Fargo building located at 2110 Eastern Avenue used by Meyers Motors for vehicle storage and office space is located in the City of Plymouth and has B-3 Business Highway District zoning. The other three parcels of land, made up of their principal building and car lot at 107 Plaza Lane, the parking lot across the street on Plaza Lane, and a small strip of land directly north of the Plaza Lane building are currently located in the Town of Plymouth. Earlier this summer, Meyer Motors approached the City of Plymouth about connecting to City utilities. Except in extremely rare circumstances, the City requires property be within the City of Plymouth to hook up to the available utilities. To that end, Meyer Motors has worked with City Attorney Fieber and prepared an annexation petition that is currently being reviewed by the State of Wisconsin Department of Administration (DOA) to annex the three parcels currently in the Town and bring them into the City. After the DOA completes their review, the Common Council will review the annexation petition. In preparation for the annexation petition to come before the Common Council, the applicant has submitted a rezoning application and a comprehensive plan amendment application to obtain appropriate City zoning. Typically, annexed property is brought in with a temporary agricultural zoning designation and the applicant would then be given 6 months to one year to rezone into the appropriate City zoning district. Since this property is already developed, staff requested the applicant to seek the appropriate City zoning district classification and comprehensive plan amendment application immediately. Motion by Nicolaus/Schmitz to approve the resolution recommending a Comprehensive plan amendment for 107 Plaza Lane and adjacent properties (parcel 59016218760, 59016218771, and 59016218772) seeking commercial land use designation on the Existing and Future Land Use Maps. Upon call of the roll, all voted aye. Motion carried. 6.) Rezoning Recommendation; A petition to rezone ~4.37 acres of land at 107 Plaza Lane and adjacent properties (parcel 59016218760, 59016218771, and 59016218772) into the B-3 Highway Business District. Meyers Motors (enclosure) This item is related to item #5. Assistant City Administrator Johnston explained that Meyer Motors would also like to obtain zoning in the B-3 Highway Business District. This would mirror the other commercial uses on this corridor and the current business use as a car dealership is a permitted use in B-3. Motion by Wyatt/Schmitz to recommend approval of a rezoning petition to rezone ~4.37 acres of land at 107 Plaza Lane and adjacent properties (parcel 59016218760, 59016218771, and 59016218772) into the B-3 Highway Business District. Upon call of the roll, all voted aye. Motion carried. Page 3 of 36 7.) Final Plat Recommendation; Consideration of phase 1 final plat for Heritage Grove residential subdivision. Neumann Developments (enclosure) The applicant, Neumann Developments, is seeking approval of a final plat for the first phase of Heritage Grove, a proposed 119-lot, ~67-acre residential subdivision. The proposed final plat includes 43 single-family residential lots with the remaining land placed in out-lot for future phases, stormwater management, as well as land dedicated to the City of Plymouth for a future neighborhood park. The applicant will pursue approval of final plats for the remainder of the preliminary plat area in future phases, which is expected to be built out over the next several years. The applicant, Kevin Andersen from Neumann Developments was present to answer questions and provided some detail to the Plan Commission on highway improvements to Highway 67 being done at the request of WisDOT. Commissioner Wyatt asked for detail on when the secondary access would connect to Greystone to the north. Assistant City Administrator Johnston noted that connection was anticipated for their phase 2 final plat and was expected in 2028. Assistant City Administrator Johnston noted a few technical comments on the plat were still outstanding and asked for a motion to recommend approval of the plat contingent on those comments being addressed. Motion by Schmitz/Nicolaus to recommend approval of the phase 1 final plat for Heritage Grove contingent on engineering comments to be addressed on the plat. Upon call of the roll, all voted aye. Motion carried. 8.) Final Plat Recommendation; Consideration of final plat for Scholar’s Ridge residential subdivision. Sheboygan County Economic Development Corporation (enclosure) Sheboygan County Economic Development Corporation (SCEDC) is requesting final plat approval for the Scholar’s Ridge residential subdivision, which will consist 102 single family lots. The subdivision’s lot size ranges from 7,216 to 22,947 square feet. The Preliminary Plat was approved by the Plan Commission at the April 9, 2026 meeting. Preliminary construction began this past summer and initial home occupancies are expected in 2027. Assistant City Administrator Johnston noted that the plat needed some technical comments addressed prior to Council approval and asked for the motion be contingent on those comments being addressed. Motion by Nicolaus/Schellin to recommend approval of the final plat for Scholar’s Ridge, contingent on engineering comments being addressed. Upon call of the roll, all voted aye. Motion carried. 9.) Staff Request: Discussion on potential zoning code audit to be incorporated into the 2027 City of Plymouth Budget. Johnston (enclosure) The City's current zoning regulations are contained in Section 13 of the City Code. The most recent comprehensive update of Section 13 occurred in June 2021, when the Common Council adopted Ordinance 2021-8 addressing the City's zoning regulations and processes. This work began in 2019 under former City administration. Bay Lakes Regional Planning Commission undertook this work for the City at that time. Page 4 of 36 Since the 2021 update, the City has continued to make targeted amendments to individual provisions of the zoning code in response to development issues, operational experience, and changes in state law. As part of the 2027 City budget, staff has currently allocated funds to conduct a “zoning code audit” to help further refine the City’s zoning code and update it as needed. A zoning code audit would be a structured review of the City of Plymouth’s existing zoning code ordinances to determine whether the regulations remain clear, internally consistent, legally current, easy to administer, and aligned with the City’s current development goals and Comprehensive Plan. An audit would not necessarily mean another wholesale rewrite. Rather, it would provide the City with an objective assessment of what portions of the 2021 code are working well, what provisions have created recurring questions or required subsequent amendments, and what changes may be appropriate to ensure the code continues to support Plymouth’s current development patterns, Comprehensive Plan, and policy objectives as outlined in the City’s recently adopted strategic plan. Commissioner Wyatt asked the approximate cost of the audit. Assistant City Administrator Johnston stated that the provided quote was just shy of $17,000. Discussion continued on the merit of an audit rather than an entire zoning code re-write since the City’s code was only about 6 years old. Johnston also noted that that planning consultant he has spoken with has ties to Plymouth. The Plan Commission directed staff to move forward with a zoning code audit if the Council would approve it as part of the budget. 10.) Communication – Letters, E-mails, or reports Related to the Plan Commission (Chairman, Secretary, Plan Commission Members, City of Plymouth Staff/Alderpersons) Assistant City Administrator Johnston confirmed the Plan Commission meeting on November 5, 2026. 11.) Adjournment Motion by Schmitz/Nicolaus to adjourn the meeting at 6:42 PM. Upon call of the roll, all voted aye. Motion carried. Meeting adjourned. Page 5 of 36 City of Plymouth 128 Smith St. - P.O. Box 107 Plymouth, WI 53073-0107 Telephone: (920) 893-3739 Facsimile: (920) 893-0183 Web Site: plymouthgov.com DATE: November 3, 2026 TO: Plan Commission FROM: Jack Johnston, Assistant City Administrator/Community Development Director RE: Conditional Use Permit Seeking Approval: 2615 Eastern Avenue, LLC (dba Carbliss Headquarters) regarding a conditional use permit (CUP) application, seeking relief from Sec. 13-1-106(a) of the City of Plymouth Code of Ordinances in order to construct three (3) digital display board signs totaling approximately 594 square feet to be located at 2615 Eastern Avenue. Excel (enclosure) Site Plan Seeking Approval: 2615 Eastern Avenue, LLC (dba Carbliss Headquarters) for the alteration of an existing parking lot, as well as the alteration of the existing building in order to construct the new Carbliss Headquarters and restaurant. Excel (enclosure) Background: Carbliss has submitted a site plan review application for a major alteration at the former K -Mart store located at 2615 Eastern Avenue. Carbliss plans to convert this building into their new headquarters as well as an adjoining restaurant called “The Pour House at Carbliss” that will predominately feature their product. The plans also call for a major overhaul to the existing parking lot adjacent to the building, fresh landscaping and signage. The signage submittal also includes three digital display board signs to be placed on the northern façade of the building facing Eastern Avenue. They are seeking a conditional use permit for this signage due to the size of the signs. More detail on the CUP and signage proposal is included later in this report. Comprehensive Plan/Zoning/Setbacks: In October of 2025, the Plan Commission approved a condo plat for this property, which includes the former K -Mart building, the Pick ‘n Save grocery store, and the smaller commercial retail storefront between the two larger tenants. The condo plat created three units and one out-lot (the parking lot). Unit 3 is the former K -Mart store and encompassed approximately 90,000 square feet of commercial real estate (~2.05 acres). Carbliss purchased this unit in the summer of 2026. The unit and property as a whole (two other units and the out-lot) are zoned B-3 Highway Business District. The B-3 district lists “professional and business offices” and “restaurants” as a permitted use. The City’s Comprehensive Plans designates this location as “commercial” on both the existing and future land use map. As such, the proposal is harmonious with City zoning and the Comprehensive Plan. Page 6 of 36 ZONING CONSISTENCY MATRIX Required Provided Zoning B-3 B-3 Minimum Frontage n/a ~700’ along Pleasant View Road; ~600’ along Eastern Avenue Maximum Lot Coverage of All Buildings 50% <25% for all units Minimum Lot Width at Building Line 100’ >800’ Minimum Front Yard Setback 50’ >80’ to east >550’ to north Minimum Side Yard Setback Principal Use Accessory Use 20’ 10’ >80’ n/a Minimum Rear Yard Setback 40’ ~300’ Maximum Height Principal Structures 35’ (up to 50’ with CUP); 25’ accessory 23’2” Parking Requirements ~141 spaces 255 spaces Façade Alterations: The attached renderings and architectural drawings show a major overhaul to the building façade. Essentially all of the existing red brick is being removed and the building will be mostly wrapped with a metal wall paneling with a primary painted color in Sherwin Williams pure white. The main secondary color on the building will be “margarita” – a shade of turquoise that will be featured beneath the Carbliss wall sign on the northwestern corner of the building as well as above the entrance to the restaurant. The color scheme matches their corporate color palette and will help with brand identity. The proposed project will result in less than 1 acre of land disturbance and will reduce overall impervious surface coverage by approximately 17,600 (+/ -) square feet. Therefore, post construction stormwater management performance standards do not apply to the project. Large floor to ceiling windows near the visitor entrance to the Carbliss Headquarters portion of the building will be featured on the north side of the building. A break in the color scheme and height of the building will create a visual separation from the corporate headquarters to the restaurant. The restaurant will feature a rooftop bar/mezzanine area above the pedestrian entrance for customers to enjoy themselves outside as well. Carbliss Headquarters/Restaurant: The Carbliss Headquarters building will be featured on the western end of building, with employee access and parking on the western parking lot. The general public entrance will be featured on the northwest corner of the building. The employee entrance will be on the western end of the building off of Pleasant View Road. The western side of the site will feature some outdoor employee amenities such as a bag toss area, a fenced in dog run, a pergola, etc. The guest entrance will be on the northwest corner and be more prominent featuring the Carbliss logo and a large canopy. The restaurant entrance will be on the northeast side of the building. As noted above, a break in building height and color scheme provides a natural separation from the headquarters portion of the building to the restaurant. The submission also includes interior blueprints of the layout of both the headquarters and restaurant for the Plan Commission to see. However, the interior layout of the building is not within the Plan Commission purview and would be reviewed as part of the building permit issuance process. Page 7 of 36 Parking Lot Plan: As a condo unit owner, Carbliss is responsible for a portion of the parking lot for the entire property along with the other unit owners. As part of their site plan review application, they have submitted a revised parking lot plan for the property for the southern end of the parking lot abutting their property. Existing paved parking areas will primarily be milled/pulverized for repaving. In total, the revised parking lot will feature 255 spaces including 7 handicap stalls which meets ADA requirements. The plan adds and revises numerous landscape islands to assist in slowing down traffic flow as well as a larger landscape buffer on the north and east side of the parking area that will better delineate the Carbliss parking area as well as assist traffic flow when entering the parking lot, especially from the northern access off of Pleasant View Drive. The southeast portion of the parking lot will feature an area for food trucks for future events. The parking plan does leave parking for adjacent businesses untouched and ensures those businesses are not losing parking as part of this revamp. Access points are not being altered as part of this plan. Current access off of Pleasant View Drive will be the primary access point to the site. Motorists off Eastern Avenue will also be able to access the site by utilizing the existing access drive and heading south and then west. Lighting/Landscaping Plan: The applicant submitted a revised landscape plan as well as photometric lighting plan. The brightest area of the site should be around the employee entrance. The plan shows 0.0 footcandles (fc) of light at property boundaries. City code requires that at least 10% of drives and parking areas to be landscaped. The current submittal puts that number around 15% and is thus conforming to code. Code also requires the applicant to indicate existing landscaping that will be removed. This includes the following: • Two evergreen trees • One Ornamental Tree • 23 Honeylocust Trees Most of these trees are on the existing landscaping islands that are being replaced and are in fair or poor condition. The proposed landscaping plan includes 42 trees around the site, shrubs, perennials, grasses etc. An irrigation system is also being proposed around the north and western sides of the building to maintain landscaping appearance. Area B: To Be Decided: A portion of the east side of the building will still be left vacant as a part of this project. Carbliss has not yet identified an end use for this space. Depending on the proposed use in the future, Plan Commission approval may or may not be required. Fire Department/Public Works/Plymouth Utilities Review: The application materials were furnished to Chief Klug and Public Works Director Austin. Chief Klug confirmed that the proposed landscape islands on the parking lot still maintain the width necessary for emergency vehicle access. Public Works Director Austin noted that no updated stormwater management would be required as the overall site impervious area is reduced by 17,642 square feet (1,816 square feet building reduction, 15,826 square feet pavement reduction). Signage/CUP Request: The submitted signage plan includes four wall signs on the northern façade facing the parking lot. One sign will go above the restaurant entrance to help delineate that part of the building. Two wall signs are shown on the architectural plans to be placed along the western edge of the northern façade near the visitor entrance to Carbliss Headquarters. A fourth wall sign is shown on the far Page 8 of 36 eastern end of the northern wall for a potential future user under the Carbliss umbrella. No exterior signage is proposed along the western wall facing Pleasant View Road at the request of staff. City code allows multiple wall signs. Size is restricted based on the linear length of the building façade. The northern façade of this property is approximately 390 feet linear feet long, meaning that wall signs totaling 390 square feet are permissible. The submitted static signage is under this threshold, totaling approximately 253 square feet. Carbliss is seeking a conditional use permit for the digital display boards due to the inclusion of these signs and their size eclipsing 390 square foot threshold for the northern facade. City code allows deviation from the City sign code on an individual basis through the use of a conditional use permit (CUP). Staff considers these digital display boards as wall signs as they are placed flush against the northern wall. In total, they are seeking three digital display boards to be separated by glass paneling. The display boards are positioned in-between the entrance to the Carbliss Headquarters and the restaurant. The rendering images included in the packet materials show how they would be utilized. They are each ~198 square feet in size (16’8” by 12 ¼”) for a total of 594 square feet in digital display boards. This, along with the 253 square feet of static wall signage totals 847 square feet of signage proposed along the northern wall compared to 390 square feet of signage that would typically be allowed through the code as written. A video of the digital display boards is attached to this report in the Attachments Section. You will need a video player on your computer to view it. The video will also be available to be viewed at the meeting. Draft Conditions for Permit: Staff and City Attorney Fieber worked with Carbliss and their engineering team at Excel on draft terms for a conditional use permit. Staff conditions address only the digital sign proposal since that is the only portion of the signage submittal that would require a CUP. Carbliss has reviewed the draft terms of the CUP and have agreed to them. However, the Plan Commission has the right to renegotiate these terms if they so choose. The draft terms of the CUP are noted below: 1. Applicant. The Conditional Use Permit (CUP) is issued to 2615 Eastern Avenue, LLC (dba Carbliss). 2. Approved Use. The CUP is issued for the construction, maintenance, display and use of the Signs, as further described in the CUP application dated September 29, 2026, attached hereto and incorporated herein (the “CUP application”). The Owner shall otherwise comply with the City of Plymouth Zoning Code, Article H, Signs and Billboards. 3. Sign Content. The signs allowed under the CUP shall be limited to the content identified in the CUP application and the Permit. No off-premises commercial advertising is allowed under any circumstances. 4. Restrictions on Digital Display Signs. Digital signage may incorporate full -motion video, animation, and changing colors, which shall be subject to review by city staff six months after the signage has been installed and is operational to verify that the digital signage has not been identified by law enforcement as a factor in any traffic related incidents. In the event the digital signage has been a factor in any traffic related incidents, the Plan Commission may revoke the allowance of the full-motion video, animation, and changing colors granted under the Permit. The digital signage shall not include strobe effects or repetitive flashing or blinking. The changing visual display shall be allowed between the hours of 7:00 a.m. and 11 p.m. During all other hours, the digital signs may be lit with a static display. Page 9 of 36 5. Approval Non-Transferable. The CUP is limited in duration to the Owner’s ownership and use of the Property and is non- transferable to subsequent owners or lessees of the Property. 6. City Staff Approval. The City of Plymouth City Administrator, Community Development Director, City Attorney, and Building Inspector, have reviewed the conditional use permit application for substantial compliance with the City of Plymouth Code of Ordinances. 7. Other Regulations. Nothing herein shall constitute a waiver or limitation of the Owner’s compliance with all other City of Plymouth ordinances and regulations, including all other requirements of the Zoning Code. 8. Enforcement. The conditions imposed herein (including the conditions imposed by any plans or changes submitted hereafter), shall all be enforced as on-going conditions of the Permit. Failure of the Owner to comply with these conditions shall entitle the City to take enforcement action, which may include forfeitures, injunctions, and/or termination of the Permit, which in turn will require the Owner to remove the signs exceeding the square footage otherwise allowed under Section 13-1-106(a). 9. Recording. A copy of this Permit, or a Memorandum of Permit, without attachments, may be recorded with the Sheboygan County Register of Deeds by either party. 10. Binding Affect: This Permit shall be binding upon both parties. Nothing herein shall be construed as limiting the right of the Owner to sell, give, or otherwise convey the Property. 11. Owner Approval. This Conditional Use shall not become effective and shall not be recorded until the Owner acknowledges his/her/its acceptance of the Permit by signing this document in the space provided below. The Owner warrants and represents that the individual signing on behalf of 2615 Eastern Avenue, LLC, has full authority to bind the Owner. Plymouth Police Department Review: The Police Department was consulted on the digital signage as a part of the CUP request. Their review of the signage is included in the packet as an attachment. Public Notices: Conditional Use Permit applications require a class 2 notice in the newspaper in consecutive weeks with the last notice published 7 days before the public hearing at the Plan Commission meeting, as well as notification letters sent to all property owners within 100’ of the subject property’s boundaries and members of the Plan Commission and Common Council. As such, a legal notice was published in the Plymouth Review on October 16 and October 23 regarding this application. A mailer was sent to nearby property owners within 100’ as well as the Plan Commission and Common Council on October 22. Conditional Use Permit Standards for Approval: The Plan Commission shall address the following, as no application for a conditional use for signage shall be granted by the Plan Commission unless the it is determined issuance of the CUP will not: 1. have a substantial adverse effect on surrounding properties by reason of appearance or other objectionable factors; 2. create a nuisance; 3. have a substantial adverse effect on property values; and 4. interfere with the reasonable enjoyment of the surrounding properties. Site Plan Standards for Approval: Page 10 of 36 Sec. 15-1-3(g) of the City Code indicates that the Plan Commission must review and approve any construction, reconstruction, expansion or conversion, except for one and two family residences in residentially zoned districts before the issuance of a building permit from the building inspector: • Site plan approval. All applications for building permits for any construction, reconstruction, expansion or conversion, except for one and two family residences in residentially zoned districts shall require site plan approval by the plan commission. When considering acting on a site plan application, the Plan Commission should consider the following: a. The appropriateness of the site plan and buildings in relation to the physical character of the site and the usage of adjoining land areas. b. The layout of the site with regard to entrances and exits to public streets; the arrangement and improvement of interior roadways; the location, adequacy and improvement of areas for parking and for loading and unloading; and shall, in this connection, sat isfy itself that the traffic pattern generated by the proposed construction or use shall be developed in a manner consistent with the safety of residents and the community, and the applicant shall so design the construction or use as to minimize any traffic hazard created thereby. c. The adequacy of the proposed water supply, drainage facilities and sanitation and waste disposal. d. The landscape and appearance of the completed site. The plan commission may require that those portions of all front, rear and side yards not used for off-street parking shall be attractively planted with trees, shrubs, plants or grass lawns, and that the site be effectively screened so as not to impair the value of adjacent properties nor impair the intent of purposes of this section. Staff Recommendation/Action Requested: Staff requests the Common Council hold a public hearing for the conditional use permit application. Staff then recommends the following: • Approval of CUP with draft conditions included in packet o If the Plan Commission wishes to amend the conditions included in the packet, staff would request the CUP be considered again at the December meeting. • Approval of Site Plan Review application as presented. Any motions to approve the conditional use permit/site plan review application should note the conditions found in City code being satisfied. Attachments: I. Applicant Materials II. Video of Digital Signage: III. Sign Review by Plymouth Police Department IV. Draft CUP Action Date Status Mail CUP notice to nearby owners; Mail CUP notice to Plan Commissioners and Common Council 10/22/2026 Mailed CUP Public Notice in Plymouth Review 10/16/2026 & 10/23/2026 Published Plan Commission meeting & Public Hearing For CUP and Site Plan Review 11/5/2026 This Meeting Page 11 of 36 October 1, 2026 Project Narrative Project: Carbliss Corporate Headquarters 2615 Eastern Ave, Plymouth, WI 53073 Carbliss is requesting approval for Site Plan Review and associated land use approvals for the redevelopment of the property located at 2615 Eastern Avenue in Plymouth, Wisconsin. The proposed project consists of the adaptive reuse of the former K-Mart building into the new Corporate Headquarters for Carbliss, 84,331 square feet. The property is approximately 16.52 acres in size and is currently zoned B-3 Business Highway District. No rezoning is required as the proposed corporate office use is consistent with the existing zoning classification. The project represents a significant private investment through the revitalization of a long-vacant commercial property and will establish a permanent headquarters location for the company. The existing building will be renovated to accommodate executive offices, administrative functions, employee workspaces, meeting and conference facilities, collaboration areas, hospitality spaces, and supporting business operations. In addition to traditional office functions, the headquarters will include a dedicated pour room where customers, distributors, vendors, and business partners may sample products in a controlled and professional setting as part of sales, marketing, and brand engagement activities. The facility will serve as the primary corporate office for Carbliss and provide a centralized location for leadership, operations, marketing, finance, customer support, and other business functions. The Carbliss project site is located on Eastern Avenue, a well-traveled commercial corridor. Like neighboring businesses that use color, overhangs, and logos to reinforce their brands, the Carbliss office and restaurant exterior reflects the company’s playful identity. White metal panels and colorful accents highlight the main entrances, while the remaining existing brick will be painted white to create a cohesive design. The site will continue to utilize its existing access configuration. Two access points are provided from Pleasant View Road, with the northernmost entrance serving as the primary entrance for employees, visitors, and customers accessing the headquarters. The existing access network and internal circulation system provide adequate connectivity to serve the proposed use while maintaining efficient traffic flow throughout the site. Existing public utilities currently serving the property will remain in use and are sufficient to support the proposed headquarters operations. Water, sanitary sewer, electric, telecommunications, and other utility infrastructure are already available to the property and will be utilized as part of the redevelopment. Connections and upgrades will be completed as necessary to accommodate building improvements and operational needs. Specifically, a new Page 12 of 36 electrical transformer, gas meter, and water and sanitary service laterals will be installed near the southwest corner of the existing building. Stormwater conveyance improvements are also proposed as part of the project. Improvements consist primarily of replacing existing inlet frames and grates with new frames and grates, as well as multiple new roof drain leads. These will be designed in accordance with applicable local and state requirements and will improve runoff collection and conveyance compared to existing conditions. Existing storm pipe televising was conducted onsite to ensure the current storm system is structurally sound and in working order. Based upon the results of this televising, select locations onsite will be further investigated and repaired as needed. Additionally, select segments of existing storm pipe will be flushed/cleaned to remove existing sediment and gravel deposits within the existing storm sewer system. The proposed project will result in less than 1 acre of land disturbance and will reduce overall impervious surface coverage by approximately 17,600 (+/-) square feet. Therefore, post construction stormwater management performance standards do not apply to the project. Existing paved parking areas will primarily be milled/pulverized for repaving activities, thereby limiting the overall amount of land disturbance onsite. The additional open lawn/landscaped areas onsite will create a more visually appealing aesthetic for the site while also reducing overall site stormwater runoff. The existing parking lot will continue to provide parking for employees, customers, vendors, and visitors. Existing asphalt, concrete, curb and gutter, and light poles will be replaced. In addition, a designated area within the parking field is proposed to accommodate food trucks, community vendors, and special events associated with headquarters operations. This area will provide opportunities for employee engagement, customer events, charitable functions, company celebrations, and community outreach activities while operating in a manner compatible with the overall site design. Landscaping improvements are proposed throughout the development and will be designed in accordance with applicable City requirements. Landscaping will enhance the appearance of the property, provide visual interest, improve screening where appropriate, and contribute to the overall character of the headquarters campus. Plant materials will be selected to promote long- term sustainability, seasonal interest, and compatibility with the site's redevelopment objectives. The proposed Corporate Headquarters represents an appropriate adaptive reuse of an existing commercial property and maintains consistency with the surrounding commercial character of the area. The redevelopment will return a vacant building to productive use, create a long-term employment center, strengthen economic activity, improve property aesthetics, and establish a permanent corporate presence within the City of Plymouth. Through substantial building, site, landscaping, and infrastructure improvements, the project will enhance the Eastern Avenue corridor while supporting the continued growth and success of Carbliss. Page 13 of 36 October 1, 2026 Conditional Use Permit Narrative – Signage Exception Request Project: Carbliss Corporate Headquarters 2615 Eastern Ave, Plymouth, WI 53073 Carbliss proposes the adaptive reuse and redevelopment of the existing vacant K-Mart commercial space located at 2615 Eastern Avenue in Plymouth, Wisconsin, into the Carbliss Corporate Headquarters. The redevelopment transforms a vacant large-format retail building into a corporate office and restaurant environment for Carbliss, while also providing space intended to serve the surrounding community. As part of the proposed redevelopment, digital displays are proposed as an integrated component of the building's architectural design. The digital displays combined with static signage designed into the project exceeds the amount otherwise permitted under the applicable signage regulations, necessitating the requested Conditional Use Permit exception. The displays are not intended to function as independent outdoor advertising structures. Rather, they are incorporated into the overall architectural design and are intended to provide identification for the Carbliss corporate office, brand- related messaging, and community-oriented announcements and programming. Existing Site Conditions The subject property consists of approximately 16.52 acres and contains a former K-Mart retail building located within the B-3 Business Highway District. The property is situated within an established commercial corridor along Eastern Avenue and is surrounded by a mixture of retail, office, service, restaurant, and commercial uses that collectively establish the commercial character of the area. A distinguishing characteristic of the site is the location of the principal building. Unlike many commercial businesses that are positioned immediately adjacent to public roadways, the former K-Mart building is located approximately 600 feet from Eastern Avenue. Additionally, portions of the building are screened from direct visibility by existing outlot developments and other site features. Although the property has substantial frontage along a major commercial corridor, visibility of the building itself is considerably reduced. These site conditions create challenges for effective headquarters identification and brand visibility that are not typically encountered by businesses located directly along the street frontage. Page 14 of 36 Description of the Requested Exception The proposed signage program includes architecturally integrated corporate-branding elements and digital-display features that exceed certain dimensional limitations contained within the City's sign regulations. We are seeking relief from 13-1-106(a) “Total sign area (including multiple business/tenant signs on a single property) shall not exceed one square foot for each lineal foot of the building parallel with the street frontage.” The proposed design shows 55 square feet of Carbliss Text, 51 square feet of Carbliss Circle, 87 square feet of Pour House, 60 square feet Entrance Signage, and 3 Digital Display Screens at 198 square feet each for a total of 847 square feet of signage on the north building frontage. We are seeking an exception of 457 square feet of wall signage from the ordinance of one square foot for each lineal foot of the building parallel with the street frontage. The signage will remain subordinate to the overall architectural character of the redevelopment and will function as part of a coordinated branding and communication program for the headquarters campus. Harmony with the Comprehensive Plan and Community Goals The proposed signage exception directly supports the adaptive reuse of a vacant commercial property and advances community objectives related to economic development, corridor revitalization, business retention, and sustainable redevelopment. The project returns a large vacant commercial building to productive use while leveraging existing roads, utility infrastructure, parking facilities, and public investments already serving the property. Redeveloping an existing site prevents additional development pressure on undeveloped land while strengthening the tax base and improving the appearance of a prominent property within the community. As the future Corporate Headquarters of Carbliss, the project also establishes a long-term employment center and serves as a destination for employees, vendors, distributors, customers, consultants, and visitors. The requested signage exception supports the visibility and identity of this headquarters use and contributes directly to the project's success. Compatibility with Surrounding Development The proposed signage remains compatible with the established commercial character of the Eastern Avenue corridor. Commercial identification signage is a standard and expected feature of commercial properties within the area. The requested signage exception supports an existing commercial use on an existing commercial property and does not introduce a new or incompatible land use. Furthermore, the signage is integrated into a broader redevelopment program that includes substantial architectural enhancements, façade modernization, landscaping improvements, parking lot enhancements, and ongoing property maintenance. Collectively, these improvements will significantly improve the visual appearance of the site compared to existing conditions. Page 15 of 36 Residential Considerations and Corridor Orientation Carbliss recognizes the importance of protecting nearby residential properties while supporting commercial redevelopment. Accordingly, the project has been intentionally designed so that the primary signage and digital- display elements face Eastern Avenue and the surrounding commercial corridor. This design approach directs visual activity toward areas where commercial identification and messaging are anticipated and expected by motorists, visitors, and customers. Signage has not been oriented toward nearby residential neighborhoods. In addition to directing visual activity toward the commercial corridor, the project includes enhanced landscaping, façade improvements, screening elements, and parking lot modifications intended to improve the transition between commercial and residential properties and further reduce potential impacts. Public Safety, Traffic and Parking The proposed signage will not materially affect traffic operations, parking demand, or public infrastructure. The site contains extensive parking and circulation facilities originally constructed to serve a high-volume regional retail use. Existing access points, parking areas, and roadway infrastructure provide more than adequate capacity to accommodate headquarters operations. Digital-display components will be professionally managed and operated in a manner that supports public safety while maintaining compatibility with surrounding development. Conclusion The requested signage exception is a critical component of the successful redevelopment of the former K-Mart property into the Carbliss Corporate Headquarters. The proposal supports the unique operational and communication needs of a modern corporate campus while remaining compatible with surrounding development and minimizing impacts on nearby residential properties. The project advances community objectives related to economic development, revitalization, and long-term investment while creating a highly visible and attractive headquarters facility within the Eastern Avenue corridor. For these reasons, Carbliss respectfully requests approval of the Conditional Use Permit and associated signage exception. Page 16 of 36 Page 17 of 36 Page 18 of 36 E SEAT COUNT = 12 ♿ ♿ DW DRY STORAGE PREP PREP WAREWASHINGIN-HOUSE CATERING COOKING CHEF TABLE ORDER PICK-UP WALK-IN COOLER WALK-IN FREEZER PAPER GOODS POSSIBLY CREATE PASSAGE FROM POUR HOUSE/BAR TO STORAGE D D D D D 48 21(5)48 21(5)48 21(5) 48 21(5) 48 21(5) 48 21(5) 48 18(5)48 18(5) D 48 21(5) 48 21(5) 48 18(5) UP • PATCH WALLS AT REMOVAL AND CONNECTION POINTS TO MATCH ADJACENT FINISHES. • PATCH WALLS AND FLOOR TO MATCH EXISTING MATERIALS AND FINISHES WHERE REMOVAL OF EXISTING CONSTRUCTION OR FINISH LEAVES DAMAGED/UNFINISHED SURFACES. THIS IS INTENDED TO COVER MISC ITEMS LIKE CABINETS, TOILET PARTITIONS, ETC. SO DON’T HAVE TO COVER EACH SITUATION. • NOT ALL INFILL OF OPENINGS AND PATCHING ARE SHOWN. INFILL ALL WALL OPENINGS TO MATCH EXISTING WALL CONSTRUCTION, PATCH TO MATCH ADJACENT SURFACES AND FINISH WHERE PIPES, CONDUIT, DUCTWORK, RECEPTACLES, SWITCHES, ETC. ARE REMOVED. • PATCH WALLS TO MATCH EXISTING MATERIALS AND FINISH WHERE NEW ELECTRICAL BOXES AND CONDUITS ARE RECESSED/CONCEALED IN EXISTING WALLS. SEE ELECTRICAL PLANS FOR LOCATIONS. • PATCH WALLS TO MATCH EXISTING MATERIALS AND FINISH WHERE NEW BLOCKING OR BACKING IS INSTALLED IN EXISTING WALLS. • COORDINATE SCHEDULING OF WORK IN EXISTING OCCUPIED AREAS WITH OWNER. ACCESS TO AREAS DURING WORK HOURS IS DEPENDENT ON OWNER’S SCHEDULE. • AT EXISTING CONSTRUCTION, INTERIOR DIMENSIONS ARE FROM EXISTING FACE OF FINISH TO NEW FACE OF STUD. • ALL INTERIOR DIMENSIONS ARE FROM FACE-OF-STUD TO FACE-OF-STUD. • SEE SPECIFICATIONS FOR WORK BY OWNER. WORK BY OWNER SHOWN ON PLANS IS SUBJECT TO CHANGE. CONTRACTOR TO COORDINATE SPECIFIC INSTALLATION REQUIREMENTS WITH OWNER/OWNER’S VENDOR. • LOCATE ALL DOORS IN METAL STUD AND MASONRY WALLS 4” FROM ADJACENT WALL UNLESS NOTED OTHERWISE. • INSTALL FIRE-TREATED WOOD BLOCKING FOR OWNER AND CONTRACTOR PROVIDED FURNISHINGS, EQUIPMENT AND WINDOW TREATMENTS (VERIFY LOCATIONS). • INSTALL GYPSUM BOARD CONTROL JOINT WITH 1/4” ‘V’ REVEAL [IN ANY WALL GREATER THAN 30’ IN LENGTH] [WHERE SHOWN ON PLANS]. POSITION ABOVE JAMB OF WALL OPENING. SEE A4 SHEETS FOR TYPICAL DETAILS. • FILL EXTERIOR LIGHT GAUGE STUD FRAMING (CLOSED JAMBS, HEADERS, ETC.) WITH MINERAL WOOL INSULATION. • COMPLETELY CONCEAL ALL SPRAY FOAM AT INTERIOR SIDE OF EXTERIOR WALLS WITH GYPSUM BOARD OR INTUMESCENT COATING (CODE REQUIRED THERMAL BARRIER). • ALL INTERIOR WALLS TO BE 6M23 U.N.O. • GYP. OR GYP. W/ FURRING IS NOT REQUIRED ON THE INTERIOR SIDE OF CHASES EXCEPT AT ALL FIRE BARRIER WALLS OR U.N.O. MATCH ADJACENT STUD THICKNESS U.N.O. GENERAL NOTES (1) HOUR FIRE RATED (2) HOUR FIRE RATED (3) HOUR FIRE RATED (4) HOUR FIRE RATED EXISTING DOOR TO REMAIN NEW DOOR SEE PLAN FOR ALL WALL WIDTHS EXTERIOR WALL TYPE • SEE A4 SHEETS FOR WALL TYPES EXIT SIGNAGE FIRE EXTINGUISHER -SEE A5 SHEETS FIRE EXTINGUISHER w/ CABINET -SEE A5 SHEETS EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED STUD WALL CONCRETE WALL MASONRY VENEER C.M.U. WALL SYMBOLS LEGEND GP-X GUARD POST/GOAL POST DESIGNATION -SEE SHEET A6.X FOR DETAILS SEE SHEET AX.X FOR CURB DETAILS CX INTERIOR WALL TYPE • SEE A4 SHEETS FOR WALL TYPES EM1 4W22 FIRE RATED WALL TYPE • SEE A4 SHEETS FOR WALL TYPES 6M23.2 FW PRECAST WALL TYPE • SEE A4 SHEETS FOR WALL TYPES 3+3+6P IMP WALL TYPE • SEE A4 SHEETS FOR WALL TYPES 6IMP PODCAST 127 MOTHERS 128 JANITOR CLOSET 133A FINANCE FLEX 113 CONFERENCE ROOM 101 EX. OFFICE 105 BREAKROOM 137 MEN'S TLT 141 KITCHEN 138 EX. OFFICE 104 TLT. 104ASTOR. 103 HR FLEX 107 HR OFFICE 108 HR OFFICE 109 WELLNESS 129 WOMEN'S TLT 142 UPS DROP OFF 156 MERCH & PRINTING SHOP 155 MEN'S LOCKERS 147 FLEX 130 FLEX 131 FLEX 132 TRAINING 136 M OFFICE 123 PRINTER HR FLEX 110 FINANCE OFFICE 114 HR FLEX 111 M FLEX 126 IT WORK SPACE 135 DEMO DISPLAY 125A COMPETITION SPACE 153A MACHINES MACHINES FITNESS 152 YOGA / FLEX 149 STORAGE 140 MEZZANINE ABOVE GRILL ZONE BAG TOSS PERGOLA ABOVE TLT 139 DOG PARK RACE SIM CONFERENCE 122 LEGAL 121 LEGAL 120 OPS FLEX 118 OPS OFFICE 117 OPS OFFICE 116 LOBBY 100 REMOTE 124 DUCKPIN BOWLING GREEN ROOM 154 FREE WEIGHT SAUNA & CRYOTHERAPY 150B SPORTS SIM DARTS PAY PHONE e2e1 eAA e3 e4 e5 e6 e7 e7A e8 eA eB eB.2 eC eC.1 eC.2 eD eD.1 eE eE.1 eF eG eH IT OFFICE 134 14'-4 3/8" 6" 18'-6" 8" 19'-6" 6" 2'-7 5/8" 6" 19'-10 7/8" 6" 8'-1 1/4" 6" 12'-0 7/8" 6" 15'-2 1/2" 6" 13'-1 1/4" 3 5/8" 5'-4" 1'-9 1/4"3'-0" 3 5/8" 10'-1 1/4" 3 5/8" 8'-1 1/4" 3 5/8" 10'-1 1/4" 3 5/8" 11'-5 5/8" 3 5/8" 11'-5 1/2" 6" 12'-1 1/4" 8" 3 5/8" 46'-5 3/8" 3 5/8" 12'-1 1/4" 3 5/8" 8'-1 1/4" 6" 7'-5 1/4" 6" 20'-7 7/8" 6" 8'-1 1/4" 8" 6" 12'-1 1/4" 6" 3 5/8" 33'-0 3/4" 8" 43'-0 1/2" 6" 8'-1 1/4" 6" 41'-8 1/4" 6" 4'-4" 6" 1'-9 1/4" 6" 12'-8 1/2" 6" 8'-1 1/4" 6" 26'-2 5/8" 6" 10'-0" 3 5/8" 9'-0 1/4" 8" 15'-2 1/4" 6" 17'-7 7/8" 77'-0" 6" 8'-1 1/4" 6" 41'-8 1/4" 6" 6'-7 1/4" 6" 6'-8 1/2" 4'-0" 2'-0" 6" 8'-1 1/4" 6" 8'-4 7/8" 3 5/8" 8'-7 1/4" 3 5/8" 8'-7 1/4" 6" 7'-9" 6" 10'-1 1/4" 6" 10'-1 1/4" 6" 10'-1 1/4" 6" 19'-10 7/8" 6" MARKETING 125 FINANCE 115 HR 112 SHOWER 144 SHOWER 146 SHOWER 145 SHOWER 143 40'-6 1/4" 6" 21'-4 7/8" 6" 21'-10 1/2" 7'-6" 8" 14'-9" 8" 28'-7 1/2"12'-0"14'-0"12'-0"36'-0"6'-0"20'-0"14'-0"8'-10"17'-4"3'-10"41'-10" OPS 119 2 A3.0 _________1 A3.0 _________ 3 A3.0 _________ 4 A3.0 _________ 12'-0 1/8" 12'-0" 12'-0 5/16" 12'-0" 12'-0" 12'-0" 6'-11 15/16" 9'-4" 2'-8" 79'-0 3/8" 6'-3" 10'-4" 107 108 110 111 113 116 117 118 122 121 120 106 STOR 106 123 124 154 125 156A156B 119 167A 149 152A WOMEN'S LOCKERS 148 136A 136B 135 132 131 130 127 133B 133A 138A 140A 138B 165166 140B 129 128 100C 100D 101C 101B PRIVATE ROOM 164 164 OUTDOOR SEATING 157 THE POUR HOUSE 158 COLD STORAGE (PUBLIC) 163 MEN'S TLT 166 WOMEN'S TLT 165 153C STORAGE 159 158A 158B 158C 158D 157C 157D CW2 CW1 CW3 CW5 GW1 GW1 GW2 GW4GW4GW4 GW4 GW4 GL5 GW6 GW6 GW6 GW7 GW6 105 GW8 153A1 GW9 153A2 7'-2 7/8" _________ A5.0 1 _________ A5.0 3 _________ A5.0 2 4M23P 4M23P 4M23P 4M23P 4M23P 4M23P 4M23P 4M23P 8M23 8M23 8M23 8M23.1 6 5/8" 22'-11 7/8" 6" 6'-2 1/2" 8" 4'-0" 8" 32'-7" 8" 20'-2 1/2" 6" 5'-1 1/4" 6" 8'-1 1/4" 8" 9'-3 3/8" 3'-4" 5'-10" 8" 3'-0" 23'-2 5/8" 6'-0 1/4" 3 5/8" 12'-1 1/4" 3 5/8" 8'-1 1/4" 6" 20'-1 1/4" 3 5/8" 8'-2 1/4" 6" 8'-1 1/4" 6" 7'-7 1/4" 6" 11'-6 5/8" 6" 8'-6" 6" 13'-7 5/8" 6" 24'-7" 6" 8'-1 1/4" 8" 16'-1 1/4" 8" 30'-7 1/8" 3'-4" 3'-7 1/2" COOLER 21'-2 1/2" 2 5/8" 8" 3 5/8" 10'-0" 6" 30'-2 1/8" 6" 18'-11 3/4" 6" 13'-3" 6" 15'-4 3/4" 6" 16'-0" 3 5/8"1'-2 3/8" 6" 61'-8 5/8" 8" 76'-3 1/8" 6" 11'-10 7/8"6"44'-4 5/8" 6" 17'-0" 6" 4M12S 4M12S 4M12S 8M23.1 8M23.1 8M23.1 8M23.1 8M23.1 8M23.1 6M12 6M12 8M23.1 8M23.1 8M23.1 6M12 6M12 6M128M23 4M23P 4M23P 4M23P 6M23 6M12 6M12 4M12 6M33 6M33 6M33 4M12S 4M12 4M12S 12'-11 3/8" 6" 3'-10" 6" 8'-1 1/4" 6" 7'-0" 6" 8'-6" 6" 5'-3" 6" 2'-0" 6'-0" 6" 1'-8" 8" EM1 EM1 EM1 EM2 EM1 EM2 126 1 1.5 2 3 4 5 6 7 8 9 10 12 11 2 A4.0 _________ 3 A4.0 _________ 5 A4.0 _________ 4 A4.0 _________ 1 A4.0 _________ 6 A4.0 _________ EM2 EB3 7 A4.0 _________ 79'-0 3/8" CW4 CW4 100A 100B 3'-11 3/4" 8'-0" 16'-0" 75.00° 100E 100F GW12 VEST. 100A TLT. 102 EXC. ASSISTANT 105A 6" 9'-9 5/8" 3 5/8" 3 5/8" 12'-0" 3 5/8" 11'-0 1/8" 6" 1'-8 3/4" 6" 10'-1 1/4" 3 5/8" 10'-1 1/4" 6" 23'-10 7/8" 134 GW10 4M23P 8" 23'-11 1/4" 8" 2 5/8" COOLER 19'-9 3/4" 5'-6" 6" 28'-0" 6" 6'-5" 6M12 IT CLOSET 133B COFFEE BAR FRIDGE / FREEZER VENDING TOWEL SERVICE GW13 3'-9" 11'-9" 7'-4" 3 5/8" 12'-0" 20'-4" 4M23 4M23 4M12S EM3 EM3 WASHER /DRYER 137A 137C 137B 157A 157B 157E SF1 SF1 SF1 SF2 CW6 CW6 SF6 SF7 SF7 (OPP.) SF8 4M23P 6" 2'-6" 6" 22'-7 1/8" 6" 2'-6" 6" 11'-4 1/4" _________ A4.2 5 155A 155B ELECTRICAL 155A 114 6M12 8M12 3 5/8" 2'-2" 4M12P 2'-2"6M12 6M12 6M12 4M12P 6M12 PRINTER 105B STORAGE 105B GW6 _________ A5.0X 4 12'-0" 21'-8" 2'-0" 8'-0" 2'-0" 8'-0" 2'-0" 8'-0" 12'-0" 8'-0" 12'-0" 8'-0" 12'-0" 8'-0" 6'-9 7/8" 167J 1'-6" STORAGE 153B 153B (2) CARBLISS WHITE BOARDS ON BACK WALL EQ EQ3'-0" 1'-6 7/8" 1'-6 7/8" 155D ALIGN 101A COLD STORAGE 153C 6M33 6M33 4M12 13'-10 5/8" MERCH 161 GALLERY 160 4'-10 5/8" STORAGE 160A 160A 159A 159B 2" GAP 2" GAP 4M12 4M12 2'-0" 2'-0" 2'-0" 6M33 6M12 6M12 6M12 4M12 6M33 8M23.1 4M12 4M23 4M12 6M12 (BELOW STAIR) 1'-0" 6'-1 1/4" 1'-0" 6M12 6M12 6M12 6M12 C12 C11 C113 5/8" 2'-4" 6" 3'-6"3 5/8" 4M23P 4M23P 4M23P 3'-8"8M23 4M23P 4M12 4M12P 4M23 20'-0" EQ EQ 18'-5 1/2"8'-10" 11'-9 3/8" EQ. 15'-6" 2'-7 5/8" EQ. EQ. EQ. EQ. EQ. 4" 7'-5" 109 GW1 2'-0" 13'-7 3/8" 1'-4" 39'-5 1/4" 8" 113.00° 90.00° 90.00° 3'-5 5/8" 2'-1 1/2" 24'-1 1/4" 1'-5 5/8" 90.00° 90.00° 113.00° 2'-7 1/2" 1'-0" 6'-4 7/8" 6" 10'-2" 6" 4'-6" 6" 8 1/2" 2'-0" 12'-11 3/8" 9'-5 3/8" 1'-9 5/8" 15'-0" 5'-6 5/8" 2'-0 5/8" 6" 3 5/8" 26'-3 3/4" 3 5/8" 6'-6 1/4" 2'-4" 3 5/8" 2'-4"8'-9 3/8" 1'-2 5/8" 8" 2'-6" 2'-3 5/8" 6" 7'-6 1/8" 6" 6'-1 1/4" 6" 7'-6 5/8" 6" 12'-1 1/2" 6" 26'-5 1/8" 6M23 6M23 6M23 6M23 6M23 3'-11 3/8" 6M23 2'-0" 6" 11'-8 1/2" 6" 12'-5 1/4" 1'-3" 16'-3" 1'-3" 34'-0" 2'-8 5/8" 1'-4" 1'-4" 5'-7 1/4" 1'-0" 6" 11'-8 1/2" 6" 8" 1'-6" 80'-11 7/8" 3'-6" 1'-2" 5" 2'-11" 2'-5" 1'-6" 4'-6" 4'-0" TIGHT CLEARANCE 3'-0" 3'-3" 4'-9 1/4" 13'-0" 9 A4.0 _________ COLD PLUNGE 8" 9'-1" 6" 6'-2" 6" 2'-6" 1'-6" FREE WEIGHT FREE WEIGHT SAUNA CRYO 10 A4.0 _________ 6M12 4M12P 4M12P4M12P4M12P 4M12P 6M23 6M33 6M23 6M12 6M12 6M12 6M12 6M12 150B HALL 101B 148147 101B 0' 8' 16' 1/8" = 1'-0"NORTH SCALE: 1/8" = 1'-0" FIRST FLOOR PLAN - AREA A AREA 'A' AREA 'B' KEY PLAN AREA 'C' AREA 'D' PROJECT INFORMATION PROFESSIONAL SEAL SHEET NUMBER JOB NUMBER PRELIMINARY DATES NOT FOR CONSTRUCTION 10/1/2026 11:45:36 AM C:\Users\reuben.rieder\Documents\250405600_ARCH_CENTRAL_V25_reuben.rieder.rvt A1.1 250405600 ARCHITECTURAL FIRST FLOOR PLAN - AREA A PROPOSED OFFICE FOR CARBLISS CORPORATE OFFICE 2615 EASTERN AVE ● PLYMOUTH, WI 53073 AUG. 28, 2026 FLOOR PLAN KEYNOTES Page 19 of 36 POSSIBLY CREATE PASSAGE FROM POUR HOUSE/BAR TO STORAGE E e7 e7A e8 e8A e8B e9 e9A e9B e10 e119 10 SHELL 167 SHELL 168 167A 140B PRIVATE ROOM 164 153C STORAGE 159 8" 8" 167E 167D167B 167C _________ A1.6 1 167F A5.3 15 14 18'-1 1/4"8"18'-7 7/16"8"28'-9 13/16"6"15'-9"8"33'-3 1/2"8"33'-4 3/8" 6'-4"40'-6"7'-0"2'-0"8'-0"4'-0"8'-0"1'-8" AREA 'A' AREA 'B' KEY PLAN AREA 'C' AREA 'D' PROJECT INFORMATION PROFESSIONAL SEAL SHEET NUMBER JOB NUMBER PRELIMINARY DATES NOT FOR CONSTRUCTION 10/1/2026 11:45:37 AM C:\Users\reuben.rieder\Documents\250405600_ARCH_CENTRAL_V25_reuben.rieder.rvt A1.2 250405600 ARCHITECTURAL FIRST FLOOR PLAN - AREA B PROPOSED OFFICE FOR CARBLISS CORPORATE OFFICE 2615 EASTERN AVE ● PLYMOUTH, WI 53073 AUG. 28, 2026 0' 8' 16' 1/8" = 1'-0"NORTH SCALE: 1/8" = 1'-0" FIRST FLOOR PLAN Page 20 of 36 EXPAN. JOINT 18" DIA. CONCRETE BOLLARD FOUNDATION W/ #5 REINF. 6"∅ STD. PIPE GUARD/GATE POST FILLED w/ CONCRETE (PAINTED) CONCRETE CAP (SMOOTH FINISH) CONC. SLAB - SEE FOUNDATION PLAN 8" 6" 1'-0" 1'-0" EQEQ 6" 3'-5 127/128" 4'-0" FOR BOLLARDS 1 1/2" 3'-5 127/128" BOND BREAKER 1" MIN. 4 1/128"9 255/256" 4" 1'-6" EQUAL EQUAL 1" GAP 6" 2 1/2"6" 6" 6" 6" 6" 2 1/2" SEE CIVIL PLANS WIDTH 1 1/2"1 1/2"1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 3 1/2"3 1/2" 1 1/2" 1 1/2" 1 1/2" HINGE POST HINGE POST LAP AND COPE (TYP.) G 1/4 3/4" STEEL PLATE w/ (2) 3/4" A325-N BOLTS (FLUSH w/ FACE OF FRAME) L2x2x3/16 WELDED GATE FRAME L2x2x3/16 DIAGONAL BRACE 3/4" STEEL PLATE w/ (2) 3/4" A325-N BOLTS (FLUSH w/ FACE OF FRAME) 3/4" STEEL PLATE w/ (2) 3/4" A325-N BOLTS (FLUSH w/ FACE OF FRAME) 3/4" STEEL PLATE w/ (2) 3/4" A325-N BOLTS (FLUSH w/ FACE OF FRAME) TOP OF SLAB _________ A1.6 8 ALL STEEL TO BE GALVANIZED INSIDE ELEVATION 3 1/2" 3 1/2" EQUAL 7 1/2" 8" G 1/4 G 1/4 G 1/4 SLOPE PER CIVIL PLANS T/O SLAB T/O SLAB T/O SLAB WIDTH WALL W IDTH W ALL W IDTH W ALL (4) #4 DIA. CONT. PREFINISHED METAL COPING 6" DIA. CONC. FILLED BOLLARD- PAINTED -SEE DETAIL THIS SHEET 6" CONC. DUMPSTER SLAB, SEE DETAIL 2/A0.1 FOR NOTES 18" DIA. CONC. BOLLARD FOUNDATION W/ #5 REINF. 1'-0" 4" 10" 4" 1'-0"11 255/256"6"8" 8" BOND BEAM W/ (2) #5 DIA. BARS CONT. 8" STRUCT. CONCRETE BRICK TO MATCH BUILDING PROVIDE HORIZ. LADDER TYPE REINF. @ 16" O.C. (1) #4 DIA. BAR AT 48" O.C. VERTICAL W/ GROUT FILLED CORES FULL HEIGHT 8'-0" 9"1'-6" 1'-3 1/4" EQ. 5/8" EQ. 5" BOTH SIDES 11" SLOT 2" COPE STEEL FRAME TO RECIEVE HSS SLEEVE 1" GAP L2x2x3/16" STL. GATE FRAME -SEE ELEVATION CEDAR BOARDS -CUT BOARDS AT SLIDE BOLT LOCATION L2x2x3/16" FOR CUT BOARD ATTACHMENT 3/16" 1 1/2" EXT. 1 1/2" EXT. 1 1/4"ø x 18" LONG A-36 ROUND BAR SLIDE BOLT 1/2"ø STL. ROD HSS 2x2x1/4 SLEEVE FIELD WELD HSS 2x2x1/4 RECIEVER SLEEVE A A ELEVATION SECTION A-A N.T.S. ALL STEEL TO BE GALVANIZED 8" 6" 6" 8 1/2"6" 1/4" 1/4"2" 1 1/2" 1 1/2" 3 1/2" 8" 3 1/2" 3 1/2" 1 1/2" 1 1/2" 1 1/2" 6" POST HEIGHT TOP OF SLAB 1/4"1 3/4" 1/4 1/4 1/4 1/4 ZERK GREASE FITTING 6" DIA STD PIPE FILLED w/ CONCRETE 3/4" STEEL STOP -POSITION SLEEVE TO ALLOW GATE TO SWING OUT 105 DEGREES 8" DIA DBL. EXTRA STRONG PIPE SLEEVE THIS SECTION OF PIPE IS NOT WELDED TO POST 8" DIA DBL. EXTRA STRONG PIPE SLEEVE 6" DIA STD PIPE FILLED w/ CONCRETE 3/4" THICK STEEL PLATE w/ (2) 13/16"ø HOLES 3/4" THICK STEEL PLATE w/ (2) 13/16"ø HOLES ZERK GREASE FITTING 8" DIA DBL. EXTRA STRONG PIPE SLEEVE ALL STEEL TO BE GALVANIZED A1.6 2 A1.63 A1.6 4 4" 10'-0" SEE CIVIL PLANS APRON DEPTH CONNECT CONCRETE APRON TO CONCRETE DUMPSTER PAD w/ #5 SMOOTH DOWELS @ 32" O.C. MIN. EMBEDMENT 8" EA. SIDE, TYP. SLOPE - SEE CIVIL DRAWINGS _________ A1.6 5 TYP. _________ A1.6 8 _________ A1.6 9 10 A1.6 _________ TYP. TYP. TYP. NOTE: ALL METAL SURFACES TO RECEIVE ONE COAST RUST-INHIBITING PRIMER AND (2) COATS PAINT. 2" X 2" T.S. FRAMED GATE W/ COMPOSITE SIDING. CONCRETE APRON SEE CIVIL FOR EXTENTS 20'-0" 1'-6" EQ EQ EQ EQ 1'-6" 1A 1x6 SQUARE EDGE TREX SELECT BOARD FASTENED TO FRAME w/ 1/2"Ø CARRIAGE BOLTS -COLOR: MILLSTONE 1A EXTERIOR MATERIAL KEY 1A BURNISHED BLOCK MFR.: COUNTY MATERIALS PRODUCT: BURNISHED BLOCK COLOR: GALAXY (63-239C) PROJECT INFORMATION PROFESSIONAL SEAL SHEET NUMBER JOB NUMBER PRELIMINARY DATES NOT FOR CONSTRUCTION 10/1/2026 11:45:39 AM C:\Users\reuben.rieder\Documents\250405600_ARCH_CENTRAL_V25_reuben.rieder.rvt A1.6 250405600 ARCHITECTURAL DUMPSTER ENCLOSURE PROPOSED OFFICE FOR CARBLISS CORPORATE OFFICE 2615 EASTERN AVE ● PLYMOUTH, WI 53073 AUG. 28, 2026 SCALE: 3/4" = 1'-0"A1.6 BOLLARD DETAIL5 SCALE: 3/4" = 1'-0"A1.6 DUMPSTER GATE ELEVATION6 SCALE: 1/2" = 1'-0"A1.6 DUMPSTER PAD DETAIL7 SCALE: 1/2" = 1'-0"A1.6 DUMPSTER WALL SECTION10 SCALE: 1 1/2" = 1'-0"A1.6 GATE SLIDE BOLT8 SCALE: 1 1/2" = 1'-0"A1.6 GATE HINGE DETAIL9 SCALE: 1/4" = 1'-0"A1.6 1 - DUMPSTER ENCLOSURE PLAN1 SCALE: 1/4" = 1'-0"A1.6 TRASH ENCLOSURE - NORTH2 SCALE: 1/4" = 1'-0"A1.6 TRASH ENCLOSURE - EAST3 SCALE: 1/4" = 1'-0"A1.6 TRASH ENCLOSURE - SOUTH4 Page 21 of 36 SEE WALL SECTIONS FOR EXTERIOR WALL CONSTRUCTION GENERAL NOTES 12B1 • REFERENCE EXTERIOR ELEVATIONS FOR VENEER CONTROL JOINTS. SEE STRUCTURAL PLANS FOR CMU CONTROL JOINT LOCATIONS. VENEER CONTROL JOINTS AND CMU CONTROL JOINTS ARE NOT REQUIRED TO ALIGN. EXTERIOR MATERIAL KEY 1 EXISTING MASONRY COLOR: MATCH COLOR OF 3A 1A BURNISHED BLOCK MFR.: COUNTY MATERIALS PRODUCT: BURNISHED BLOCK COLOR: GALAXY (63-239C) 3A METAL WALL PANELING MANUF: TBD COLOR: PAINTED, SHERWIN WILLIAMS PURE WHITE 3B COLOR: MARGARITA PANTONE: 7464 C 3C COLOR: BLACK WRAPPED WITH SOLOID COLOR VINYL 4 DIGITAL DISPLAY BOARD 5 H.M. DOOR & FRAME COLOR: SHERWIN WILLIAMS PURE WHITE 6 OH DOOR PANEL COLOR: WHITE (SEND ARCH. PHYSICAL SAMPLES FOR SELECTION) 7 ALUMINUM WINDOW FRAMING & GLAZING FRAME COLOR: SEE WINDOW SPEC GLAZING COLOR: SEE GLAZING SPEC 9 METAL TRIM COLOR: BLACK FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" e2e1 e3 e4 e5 e6 e7 e7A e8 e8A e8B e9 e9A e9B e10 e11 3A ROOF TOP 111'-0" 3B 1 1.5 2 3 4 5 6 7 8 9 10 T.O. PARAPET 123'-0" 1 1 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" eAA eA eB eB.2 eC eC.1 eC.2 eD eD.1 eE eE.1 eF eG eH 3A 3B 1 57 77 7 ROOF TOP 111'-0" 77 3B3B 12 11 T.O. PARAPET 123'-0" 7 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" eAAeAeBeB.2eCeC.1eC.2eDeD.1eEeE.1eFeGeH 2 ROOF TOP 111'-0" 1211 T.O. PARAPET 123'-0" 6 6 5 5 1 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" e2 e1e3e4e5e6e7e7Ae8e8Ae8Be9e9Ae9Be10e11 1 3A ROOF TOP 111'-0" 3B 73B 7 7 7 3F 11.52345678910 T.O. PARAPET 123'-0" 3E 3D 3C 7 444 77 3A 7 7 7 1A T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" ROOF TOP 111'-0" 1211 T.O. PARAPET 123'-0" 3A 3B T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" ROOF TOP 111'-0" 12 11 T.O. PARAPET 123'-0" 3A 3B T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" PROJECT INFORMATION PROFESSIONAL SEAL SHEET NUMBER JOB NUMBER PRELIMINARY DATES NOT FOR CONSTRUCTION 10/1/2026 11:35:56 AM C:\Users\reuben.rieder\Documents\250405600_ARCH_CENTRAL_V25_reuben.rieder.rvt A2.0 250405600 ARCHITECTURAL EXTERIOR ELEVATIONS PROPOSED OFFICE FOR CARBLISS CORPORATE OFFICE 2615 EASTERN AVE ● PLYMOUTH, WI 53073 AUG. 28, 2026 SCALE: 3/32" = 1'-0"A2.0 SOUTH ELEVATION3 SCALE: 3/32" = 1'-0"A2.0 WEST ELEVATION2 SCALE: 3/32" = 1'-0"A2.0 EAST ELEVATION4 SCALE: 3/32" = 1'-0"A2.0 NORTH ELEVATION1 SCALE: 3/32" = 1'-0"A2.0 EAST HIDDEN ELEVATION6 SCALE: 3/32" = 1'-0"A2.0 WEST HIDDEN ELEVATION7 Page 22 of 36 SEE WALL SECTIONS FOR EXTERIOR WALL CONSTRUCTION GENERAL NOTES 12B1 • REFERENCE EXTERIOR ELEVATIONS FOR VENEER CONTROL JOINTS. SEE STRUCTURAL PLANS FOR CMU CONTROL JOINT LOCATIONS. VENEER CONTROL JOINTS AND CMU CONTROL JOINTS ARE NOT REQUIRED TO ALIGN. EXTERIOR MATERIAL KEY 1 EXISTING MASONRY COLOR: MATCH COLOR OF 3A 1A BURNISHED BLOCK MFR.: COUNTY MATERIALS PRODUCT: BURNISHED BLOCK COLOR: GALAXY (63-239C) 3A METAL WALL PANELING MANUF: TBD COLOR: PAINTED, SHERWIN WILLIAMS PURE WHITE 3B COLOR: MARGARITA PANTONE: 7464 C 3C COLOR: BLACK WRAPPED WITH SOLOID COLOR VINYL 4 DIGITAL DISPLAY BOARD 5 H.M. DOOR & FRAME COLOR: SHERWIN WILLIAMS PURE WHITE 6 OH DOOR PANEL COLOR: WHITE (SEND ARCH. PHYSICAL SAMPLES FOR SELECTION) 7 ALUMINUM WINDOW FRAMING & GLAZING FRAME COLOR: SEE WINDOW SPEC GLAZING COLOR: SEE GLAZING SPEC 9 METAL TRIM COLOR: BLACK FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" e2e1 e3 e4 e5 e6 e7 e7A e8 e8A e8B e9 e9A e9B e10 e11 3A ROOF TOP 111'-0" 3B 1 1.5 2 3 4 5 6 7 8 9 10 T.O. PARAPET 123'-0" 1 1 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" eAA eA eB eB.2 eC eC.1 eC.2 eD eD.1 eE eE.1 eF eG eH 3A 3B 1 57 77 7 ROOF TOP 111'-0" 77 3B3B 12 11 T.O. PARAPET 123'-0" 7 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" eAAeAeBeB.2eCeC.1eC.2eDeD.1eEeE.1eFeGeH 2 ROOF TOP 111'-0" 1211 T.O. PARAPET 123'-0" 6 6 5 5 1 T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" e2 e1e3e4e5e6e7e7Ae8e8Ae8Be9e9Ae9Be10e11 1 3A ROOF TOP 111'-0" 3B 73B 7 7 7 3F 11.52345678910 T.O. PARAPET 123'-0" 3E 3D 3C 7 444 77 3A 7 7 7 1A T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" ROOF TOP 111'-0" 1211 T.O. PARAPET 123'-0" 3A 3B T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" FIRST FLOOR 100'-0" ROOF 120'-0" MEZZANINE 109'-4" ROOF TOP 111'-0" 12 11 T.O. PARAPET 123'-0" 3A 3B T.O. PARAPET LOW 121'-4" T.O. PARPET MID 122'-0" PROJECT INFORMATION PROFESSIONAL SEAL SHEET NUMBER JOB NUMBER PRELIMINARY DATES NOT FOR CONSTRUCTION 10/1/2026 11:35:56 AM C:\Users\reuben.rieder\Documents\250405600_ARCH_CENTRAL_V25_reuben.rieder.rvt A2.0 250405600 ARCHITECTURAL EXTERIOR ELEVATIONS PROPOSED OFFICE FOR CARBLISS CORPORATE OFFICE 2615 EASTERN AVE ● PLYMOUTH, WI 53073 AUG. 28, 2026 SCALE: 3/32" = 1'-0"A2.0 SOUTH ELEVATION3 SCALE: 3/32" = 1'-0"A2.0 WEST ELEVATION2 SCALE: 3/32" = 1'-0"A2.0 EAST ELEVATION4 SCALE: 3/32" = 1'-0"A2.0 NORTH ELEVATION1 SCALE: 3/32" = 1'-0"A2.0 EAST HIDDEN ELEVATION6 SCALE: 3/32" = 1'-0"A2.0 WEST HIDDEN ELEVATION7 Page 23 of 36 STAKEOUT INFORMATION:VERIFY STATION FOR INLET LOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION: VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICY FOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION: VERIFY STATION FOR INLET LOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C0.1 CIVIL COVER SHEET IFA OCT. 1, 2026PROJECT LOCATION CARBLISS CORPORATE OFFICE PROPOSED OFFICE FOR: PLYMOUTH, WI PROJECT INFORMATION SHEET INDEX NUMBER SHEET NAME / DESCRIPTION C0.1 COVER SHEET C0.2 SPECIFICATIONS C1.0 EXISTING SITE AND DEMOLITION PLAN C1.1 SITE PLAN C1.2 GRADING AND EROSION CONTROL PLAN C1.3 UTILITY PLAN C1.4 LANDSCAPE AND RESTORATION PLAN C2.0 DETAILS C3.1 SITE PHOTOMETRIC PLAN & DETAILS LOCATION MAP PROJECT CONTACTS OWNER INFORMATION: CIVIL: CARBLISS Amanda Kroener Email: amanda@drinkcarbliss.com (414) 588-1433 JASON DAYE Phone: (920) 322-1687 E-mail: jason.daye@excelengineer.com SITE PLAN OVERVIEW TO OBTAIN LOCATION OF PARTICIPANTS' UNDERGROUND FACILITIES BEFORE YOU DIG IN WISCONSIN CALL DIGGERS HOTLINE 1-800-242-8511 TOLL FREE TELEFAX (414) 259-0947 TDD (FOR THE HEARING IMPAIRED) 1-800 542-2289 WISCONSIN STATUTE 182.0175 (1974) REQUIRES MINIMUM OF 3 WORK DAYS NOTICE BEFORE YOU EXCAVATE 100' 0 100' 200' SCALE: 1"= 100' 1. ALL DRIVEWAYS AND CURB CUTS TO BE CONSTRUCTED ACCORDING TO LOCAL ORDINANCES. CONTRACTOR TO OBTAIN ALL NECESSARY PERMITS. 2. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL WORK IN ROW PERMITS. GENERAL PROJECT NOTES CONSTRUCTION STAKING SHALL BE COMPLETED BY EXCEL ENGINEERING AS REQUESTED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. CONTRACTOR TO CONTACT RYAN WILGREEN AT 920-926-9800 OR RYAN.W@EXCELENGINEER.COM TO GET STAKING PRICE TO INCLUDE IN BID TO OWNER. PAYMENT OF STAKING COSTS ABOVE AND BEYOND THE BASE PRICE DUE TO RESTAKING WILL BE THE RESPONSIBILITY OF THE CONTRACTOR, NOT THE OWNER. CAD DRAWING FILES AND SURVEY CONTROL WILL NOT BE PROVIDED FOR STAKING PURPOSES. CONSTRUCTION STAKING SERVICES PROJECT NOTES PROPERTY AREA: 719,819 S.F. (16.52 ACRES). EXISTING ZONING: B-3 BUSINESS HIGHWAY PROPOSED ZONING: B-3 BUSINESS HIGHWAY PROPOSED USE: CORPORATE OFFICE AREA OF SITE DISTURBANCE: 41,085 SF (0.94 ACRES) SETBACKS: BUILDING: FRONT(NORTH/WEST) = 50' SIDE(SOUTH/EAST) = 20' REAR = 40' PAVEMENT: FRONT(NORTH/WEST) = 15' PARKING REQUIRED: MINIMUM 1 SPACE PER 200 SQFT OF FLOOR SPACE PER B-3 (241 SPACES REQ) PARKING PROVIDED: 255 SPACES (7 H.C. ACCESSIBLE) HANDICAP STALLS REQUIRED: 7, HANDICAP STALLS PROVIDED: 7 SITE INFORMATION: CITY PLANNER: JACK JOHNSTON Phone: (920) 893-3739 E-mail: jjohnston@plymouthwi.gov CITY ENGINEER/ DIRECTOR OF PUBLIC WORKS: CATHY AUSTIN Phone: (920) 839-1471 E-mail: caustin@plymouthwi.gov CITY FIRE CHIEF: JIM KLUG Phone: (920) 893-1331 E-mail: jklug@plymouthwi.gov CITY BUILDING INSPECTOR: BRIAN WITKOWSKI E-mail: inspections.plymouthwi.gov NORTH NORTH NORTH 000.00 C E T T 800 800 000.00 FL 000.00 TC 000.00 BW 000.00 TW FOR STAKEOUT LOCATION AND OFFSETS. LOCATION. REFER TO STAKEOUT POLICY VERIFY STATION FOR INLET STAKEOUT INFORMATION: STAKEOUT INFORMATION: VERIFY STATION FOR INLET LOCATION. REFER TO STAKEOUT POLICY FOR STAKEOUT LOCATION AND OFFSETS. 000.00 FG 000.00 BG NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS. IDENTIFICATIONSYM. LEGEND PROPOSED SPOT ELEVATIONS (FLOW LINE OF CURB UNLESS OTHERWISE SPECIFIED) EXISTING GRADE SPOT ELEVATIONS PROPOSED SPOT ELEVATIONS (REFERENCE R-WALL DETAIL) BG-FINISHED SURFACE GRADE AT BACK OF WALL FG-FINISHED SURFACE GRADE AT FRONT OF WALL PROPOSED SPOT ELEVATIONS (TOP OF CURB, FLOWLINE OF CURB) PROPOSED SPOT ELEVATIONS (TOP OF WALK, BOTTOM OF WALK @ FLOWLINE) 000.00 EG EXISTING WATER VALVE IN BOX PROPOSED WATER VALVE IN BOX EXISTING WATER VALVE IN MANHOLE EXISTING WATER SERVICE VALVE EXISTING TELEPHONE MANHOLE EXISTING STORM CATCH BASIN PROPOSED STORM CATCH BASIN - ST CB PROPOSED STORM FIELD INLET - ST FI EXISTING SQUARE CATCH BASIN EXISTING STORM CURB INLET PROPOSED STORM CURB INLET - ST CI EXISTING UTILITY POLE EXISTING UTILITY POLE WITH GUY WIRE EXISTING STREET LIGHT EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC PEDESTAL EXISTING ELECTRIC BOX EXISTING CABLE TV PEDESTAL PROPOSED DRAINAGE FLOW 1-1/4" REBAR SET WEIGHING 4.30 LB/FT. 3/4" REBAR SET WEIGHING 1.50 LB/FT. 1-1/4" REBAR FOUND 3/4" REBAR FOUND 2" IRON PIPE FOUND 1" IRON PIPE FOUND EXISTING FLOOD LIGHT SECTION CORNER PROPOSED APRON END SECTION EXISTING MARSH AREA EXISTING DECIDUOUS TREE WITH TRUNK DIAMETER EXISTING CONIFEROUS TREE EXISTING SHRUB EXISTING STUMP SOIL BORING EXISTING WELL PROPOSED WELL PROPOSED LIGHT POLE EXISTING LIGHT POLE PROPOSED SIGN EXISTING SIGN CENTER LINE EXISTING HANDICAP PARKING STALL PROPOSED HANDICAP PARKING STALL EXISTING GAS VALVE EXISTING WOODED AREA EXISTING HEDGE EXISTING CHAINLINK FENCE EXISTING WOOD FENCE EXISTING BARBED WIRE FENCE EXISTING GUARD RAIL EXISTING STORM SEWER AND MANHOLE PROPOSED STORM SEWER AND MANHOLE - ST MH EXISTING SANITARY SEWER AND MANHOLE PROPOSED SANITARY SEWER AND MANHOLE - SAN MH EXISTING WATER LINE AND HYDRANT PROPOSED WATER LINE AND HYDRANT EXISTING OVERHEAD UTILITY LINE EXISTING UNDERGROUND FIBER OPTIC LINE EXISTING UNDERGROUND ELECTRIC CABLE EXISTING UNDERGROUND TELEPHONE CABLE EXISTING UNDERGROUND GAS LINE EXISTING CURB AND GUTTER GRADING/SEEDING LIMITS RIGHT-OF-WAY LINEINTERIOR PROPERTY LINE RAILROAD TRACKS EXISTING GROUND CONTOUR EXISTING POLISH SEWER AND MANHOLE PROPOSED POLISH SEWER AND MANHOLE EXISTING PROCESS SEWER AND MANHOLE PROPOSED PROCESS SEWER AND MANHOLE EXISTING CLEAR WATER LINE PROPOSED CLEAR WATER LINE PROPOSED CURB AND GUTTER PROPOSED GROUND CONTOUR IDENTIFICATIONSYM. PROPOSED CLEANOUT PROPOSED DOWNSPOUT TO GRADE SPOT ELEVATIONS EXISTING SITE SYMBOLS EXISTING LINETYPES PROPOSED SITE SYMBOLS PROPOSED LINETYPES PROPOSED UNDERGROUND GAS LINE PROPOSED UNDERGROUND TELEPHONE CABLE PROPOSED UNDERGROUND ELECTRIC CABLE PROPOSED UNDERGROUND FIBER OPTIC LINE PROPOSED GUARD RAIL MATCHLINE PROPOSED PROPERTY LINE PROPOSED OVERHEAD UTILITY LINE PROPOSED CHAINLINK FENCE PROPOSED WOOD FENCE PROPOSED BARBED WIRE FENCE PROPOSED WATER VALVE IN MANHOLE PROPOSED WATER SERVICE VALVE SHEETS BELOW INTENDED TO BE PRINTED IN: COLOR. REFER TO DIGITAL FORMAT DRAWINGS IF PRINTED GRAYSCALE TO ENSURE SCOPE CLARITY. PROPOSED DOWNSPOUT TO RISER EXISTING PROJECT AREA DATA (AREA OF CONSTRUCTION) AREA (AC) AREA (SF) RATIO BUILDING FLOOR AREA 0.09 4,108 2.2% PAVEMENT (ASP. & CONC.) 3.64 158,431 85.9% TOTAL IMPERVIOUS 3.73 162,539 88.2% LANDSCAPE/ OPEN SPACE 0.50 21,842 11.8% PROJECT SITE 4.23 184,381 100.0% PROPOSED PROJECT AREA DATA (AREA OF CONSTRUCTION) AREA (AC) AREA (SF) RATIO BUILDING FLOOR AREA 0.05 2,292 1.2% PAVEMENT (ASP. & CONC.) 3.27 142,605 77.3% TOTAL IMPERVIOUS 3.33 144,897 78.6% LANDSCAPE/ OPEN SPACE 0.91 39,484 21.4% PROJECT SITE 4.23 184,381 100.0% ARCHITECT: DAVID VANDEN AVOND Phone: (920) 322-1674 E-mail: david.vandenavond@excelengineer.com 10/01/26 Page 24 of 36 SHEET DATES ISSUED FOR APPROVAL C0.2 CIVIL SPECIFICATIONS IFA OCT. 1, 2026 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 CIVIL SPECIFICATIONS SHOP DRAWING SUBMITTALS MATERIAL / INFORMATION 1. 31.10.00 - TELEVISING REPORTS OF EXISTING LATERALS · STORM · SANITARY 3. 32.10.00 (A) - AGGREGATE BASE & ASPHALT PAVEMENT · HOT MIX ASPHALT SPECIFICATIONS · AGGREGATE BASE · PAVEMENT MARKINGS 4. 32.20.00-CONCRETE AND AGGREGATE BASE · DESIGN MIX · AGGREGATE BASE · COMPRESSION TEST RESULTS · DETECTABLE WARNING PLATES 5. 32.30.00 LANDSCAPING · AMENDED SOIL MIX · SEEDING PRODUCT DATA · PLANTING SUBSTITUTION SCHEDULE 6. 33.10.00 - SITE UTILITIES · SANITARY & STORM MANHOLES · SANITARY PIPING MATERIALS · WATER PIPING MATERIALS · WATER FITTINGS & APPURTENANCES · STORM PIPING MATERIALS 7. MISCELLANEOUS ITEMS · FENCING · SITE LIGHTING · EXTERIOR SIGNAGE · BOLLARDS DIVISION 31 EARTH WORK 31 10 00 SITE CLEARING (DEMOLITION) A. CONTRACTOR SHALL CALL DIGGER'S HOT LINE AND CONDUCT A PRIVATE UTILITY LOCATE AS REQUIRED TO ENSURE THAT ALL UTILITIES HAVE BEEN LOCATED BEFORE STARTING SITE DEMOLITION. DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES BETWEEN PLAN AND FIELD CONDITIONS PRIOR TO CONSTRUCTION. B. CONTRACTOR TO FIELD TELEVISE ALL EXISTING SANITARY AND STORM LATERALS THAT ARE SCHEDULED TO BE RE-USED AND/OR CONNECTED TO ON SITE AT TIME OF DEMOLITION. THE TELEVISING SHALL BE COMPLETED TO ENSURE THE EXISTING LATERAL(S) ARE FREE OF OBSTRUCTIONS AND IN SOUND STRUCTURAL CONDITION. TELEVISING OF THESE LATERAL(S) SHOULD BE COMPLETED AT BEGINNING OF CONSTRUCTION AND DESIGN ENGINEER SHALL BE NOTIFIED OF ANY PIPE OBSTRUCTIONS AND/OR STRUCTURAL DEFICIENCIES IMMEDIATELY AFTER COMPLETION OF FIELD TELEVISING. C. DEMOLITION PLAN IS AN OVERVIEW OF DEMOLITION TO TAKE PLACE ON SITE. CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO BIDDING. CONTRACTOR SHALL REMOVE, REPLACE, OR DEMOLISH ALL ITEMS AS NEEDED DURING CONSTRUCTION. D. CONTRACTOR TO PROTECT EXISTING IMPROVEMENTS THAT ARE SCHEDULED TO REMAIN. ANY DAMAGE TO EXISTING FACILITIES SHALL BE REPLACED AT CONTRACTORS EXPENSE. E. ALL CONCRETE NOTED TO BE REMOVED SHALL BE REMOVED TO THE NEAREST CONTROL JOINT. 31 20 00 EARTH MOVING A. CONTRACTOR SHALL CALL DIGGER'S HOT LINE AND CONDUCT A PRIVATE UTILITY LOCATE AS REQUIRED TO ENSURE THAT ALL UTILITIES HAVE BEEN LOCATED BEFORE STARTING EXCAVATION. DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES BETWEEN PLAN AND FIELD CONDITIONS PRIOR TO CONSTRUCTION. B. PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT FOR ALL EXCAVATION, GRADING, FILL AND BACKFILL WORK AS REQUIRED TO COMPLETE THE GENERAL CONSTRUCTION WORK. ALL EXCAVATION AND BACKFILL FOR ELECTRICALS AND MECHANICALS ARE THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR UNLESS OTHERWISE SPECIFIED IN THE BID DOCUMENTS. C. ALL ORGANIC TOPSOIL INSIDE THE BUILDING AREA, UNDER PAVED AREAS, AND AT SITE FILL AREAS SHALL BE REMOVED. PROOF ROLL SUBGRADES BEFORE PLACING FILL WITH HEAVY PNEUMATIC-TIRED EQUIPMENT, SUCH AS A FULLY-LOADED TANDEM AXLE DUMP TRUCK, TO IDENTIFY SOFT POCKETS AND AREAS OF EXCESS YIELDING. CONTRACTOR SHALL VERIFY TOPSOIL DEPTHS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REVIEW AND FOLLOW THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT AND ACCOUNT FOR EXISTING CONDITIONS PRIOR TO SUBMITTING BID FOR THE PROJECT. EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE UNLESS OTHERWISE DIRECTED IN THE PLANS OR BY LOCAL ZONING REQUIREMENTS. D. PLACE AND COMPACT FILL MATERIAL IN LAYERS TO REQUIRED ELEVATIONS. UNIFORMLY MOISTEN OR AERATE SUBGRADE AND EACH SUBSEQUENT FILL OR BACKFILL LAYER BEFORE COMPACTION AS RECOMMENDED TO ACHIEVE SPECIFIED DRY DENSITY. REMOVE AND REPLACE, OR SCARIFY AND AIR DRY, OTHERWISE SATISFACTORY SOIL MATERIAL THAT IS TOO WET TO COMPACT TO SPECIFIED DRY DENSITY. E. PLACE BACKFILL AND FILL MATERIALS IN LAYERS NOT MORE THAN 8" IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HEAVY COMPACTION EQUIPMENT, AND NOT MORE THAN 4" IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HAND-OPERATED TAMPERS. F. COMPACT THE SOIL TO NOT LESS THAN THE FOLLOWING PERCENTAGES OF MAXIMUM DRY DENSITY ACCORDING TO ASTM D 698, STANDARD PROCTOR TEST. FILL MAY NOT BE PLACED ON FROZEN GROUND AND NO FROZEN MATERIALS MAY BE USED FOR BACK FILL. APPLY THE MORE STRINGENT REQUIREMENTS WHEN COMPARING BETWEEN THE FOLLOWING AND THE GEOTECHNICAL REPORT. 1. UNDER FOUNDATIONS - SUBGRADE, AND EACH LAYER OF BACKFILL OR FILL MATERIAL, TO NOT LESS THAN 98 PERCENT. 2. UNDER INTERIOR SLAB-ON-GRADE WHERE GROUNDWATER IS MORE THAN 3 FEET BELOW THE SLAB - PLACE A DRAINAGE COURSE LAYER OF 3/4" CRUSHED STONE, WITH 5% TO 12% FINES, PER THICKNESS INDICATED ON FOUNDATION PLANS ON PREPARED SUBGRADE. COMPACT THE SUBGRADE AND DRAINAGE COURSE TO NOT LESS THAN 95 PERCENT. 3. UNDER INTERIOR SLAB-ON-GRADE WHERE GROUNDWATER IS WITHIN 3 FEET OF THE SLAB SURFACE- PLACE A DRAINAGE COURSE LAYER OF CLEAN 3/4" CRUSHED STONE, WITH NO MORE THAN 5% FINES, PER THICKNESS INDICATED ON FOUNDATION PLANS ON PREPARED SUBGRADE. COMPACT THE SUBGRADE AND DRAINAGE COURSE TO NOT LESS THAN 95 PERCENT. 4. UNDER EXTERIOR CONCRETE AND ASPHALT PAVEMENTS - COMPACT THE SUBGRADE AND EACH LAYER OF BACKFILL OR FILL MATERIAL TO NOT LESS THAN 95 PERCENT. 5. UNDER WALKWAYS - COMPACT SUBGRADE AND EACH LAYER OF BACKFILL OR FILL MATERIAL TO NOT LESS THAN 95 PERCENT. 6. UNDER LAWN OR UNPAVED AREAS - COMPACT SUBGRADE AND EACH LAYER OF BACKFILL OR FILL MATERIAL, TO NOT LESS THAN 85 PERCENT. G. CONTRACTOR SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO PERFORM FIELD TESTS AND INSPECTIONS. CONTRACTOR SHALL PROVIDE DOCUMENTATION OF PASSING DENSITY TESTING AND PROOF-ROLLING TO ENGINEER UPON COMPLETION. IT IS SUGGESTED THAT THE GEOTECHNICAL FIRM USED TO PERFORM THE SUBSURFACE SOIL INVESTIGATION BE ENGAGED FOR THE FIELD QUALITY CONTROL TESTS. H. ALLOW THE TESTING AGENCY TO TEST AND INSPECT SUBGRADES AND EACH FILL OR BACKFILL LAYER. PROCEED WITH SUBSEQUENT EARTHWORK ONLY AFTER TEST RESULTS FOR PREVIOUSLY COMPLETED WORK COMPLY WITH REQUIREMENTS. PROVIDE ONE TEST FOR EVERY 2000 SQUARE FEET OF PAVED AREA OR BUILDING SLAB, ONE TEST FOR EACH SPREAD FOOTING, AND ONE TEST FOR EVERY 50 LINEAR FEET OF WALL STRIP FOOTING. I. WHEN THE TESTING AGENCY REPORTS THAT SUBGRADES, FILLS, OR BACKFILLS HAVE NOT ACHIEVED DEGREE OF COMPACTION SPECIFIED, SCARIFY AND MOISTEN OR AERATE, OR REMOVE AND REPLACE SOIL TO DEPTH REQUIRED; RECOMPACT AND RETEST UNTIL SPECIFIED COMPACTION IS OBTAINED. J. THE BUILDING SITE SHALL BE GRADED TO PROVIDE DRAINAGE AWAY FROM THE BUILDING AS INDICATED ON THE PLANS. SITE EARTHWORK SHALL BE GRADED TO WITHIN 0.10' OF REQUIRED EARTHWORK ELEVATIONS ASSUMING POSITIVE DRAINAGE IS MAINTAINED IN ACCORDANCE WITH THE GRADING PLAN. 31 30 00 EROSION CONTROL A. THE GRADING PLAN REFLECTS LESS THAN 1 ACRE OF DISTURBED AREA. THE SITE IS THEREFORE EXEMPT FROM WISCONSIN DEPARTMENT OF NATURAL RESOURCES NR 216 NOTICE OF INTENT REQUIREMENTS. THE DESIGN ENGINEER SHALL PREPARE AN EROSION CONTROL PLAN TO MEET NR 151.105 CONSTRUCTION SITE PERFORMANCE STANDARDS FOR NON-PERMITTED SITES. B. EROSION AND SEDIMENT CONTROL IMPLEMENTED DURING CONSTRUCTION SHALL STRICTLY COMPLY WITH THE GUIDELINES AND REQUIREMENTS SET FORTH IN WISCONSIN ADMINISTRATIVE CODE (W.A.C.) NR 151, THE STATE OF WISCONSIN DEPARTMENT OF NATURAL RESOURCES RUNOFF MANAGEMENT PERFORMANCE STANDARDS. TECHNICAL STANDARDS PUBLISHED BY THE WISCONSIN DNR SHALL ALSO BE UTILIZED TO IMPLEMENT THE REQUIRED PERFORMANCE STANDARDS. THE METHODS AND TYPES OF EROSION CONTROL WILL BE DEPENDENT ON THE LOCATION AND TYPE OF WORK INVOLVED. ALL SEDIMENT CONTROL MEASURES SHALL BE ADJUSTED TO MEET FIELD CONDITIONS AT THE TIME OF CONSTRUCTION, AND INSTALLED PRIOR TO ANY GRADING OR DISTURBANCE OF EXISTING SURFACE MATERIAL. BELOW IS A LIST OF EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES TO ACHIEVE THE PERFORMANCE STANDARDS REQUIRED. 1. SILT FENCE SHALL BE PLACED ON SITE AT LOCATIONS SHOWN ON THE EROSION CONTROL PLAN. SILT FENCE SHALL ALSO BE PROVIDED AROUND THE PERIMETER OF ALL SOIL STOCKPILES THAT WILL EXIST FOR MORE THAN 7 DAYS. FOLLOW PROCEDURES FOUND IN WISCONSIN DNR TECHNICAL STANDARD 1056 (CURRENT EDITION). 2. DITCH CHECKS SHALL BE PROVIDED TO REDUCE THE VELOCITY OF WATER FLOWING IN DITCH BOTTOMS. PLACE AT LOCATIONS SHOWN ON THE EROSION CONTROL PLAN. FOLLOW PROCEDURES FOUND IN WISCONSIN DNR TECHNICAL STANDARD 1062 (CURRENT EDITION). 3. STONE TRACKING PADS AND TRACKOUT CONTROL PRACTICES SHALL BE PLACED AT ALL CONSTRUCTION SITE ENTRANCES AND SHALL BE INSTALLED PRIOR TO ANY TRAFFIC LEAVING THE CONSTRUCTION SITE. SEE THE EROSION CONTROL PLAN FOR LOCATIONS. THE AGGREGATE USED FOR THE STONE TRACKING PAD SHALL BE 3 INCH TO 6 INCH CLEAR OR WASHED STONE AND SHALL BE PLACED IN A LAYER AT LEAST 12 INCHES THICK. THE STONE SHALL BE UNDERLAIN WITH A WISDOT TYPE R GEOTEXTILE FABRIC AS NEEDED. THE TRACKING PAD SHALL BE THE FULL WIDTH OF THE EGRESS POINT (12' MIN WIDTH) AND SHALL BE A MINIMUM OF 50 FEET LONG. SURFACE WATER MUST BE PREVENTED FROM PASSING THROUGH THE TRACKING PAD. OTHER TRACKOUT CONTROL PRACTICES INCLUDING STABILIZED WORK SURFACES, MANUFACTURED TRACKOUT CONTROL DEVICES, TIRE WASHING, AND STREET/PAVEMENT CLEANING SHALL BE IMPLEMENTED AS NECESSARY TO MITIGATE THE TRACKOUT OF SEDIMENT OFFSITE. FOLLOW PROCEDURES FOUND IN WISCONSIN DNR TECHNICAL STANDARD 1057 (CURRENT EDITION). 4. STORM DRAIN INLET PROTECTION SHALL BE PROVIDED FOR ALL NEW AND DOWNSTREAM STORM CATCH BASINS AND CURB INLETS. TYPE B OR C PROTECTION SHOULD BE PROVIDED AND SHALL BE IN CONFORMANCE WITH WISCONSIN DNR TECHNICAL STANDARD 1060 (CURRENT EDITION). 5. DUST CONTROL MEASURES SHALL BE PROVIDED TO REDUCE OR PREVENT THE SURFACE AND AIR TRANSPORT OF DUST DURING CONSTRUCTION. CONTROL MEASURES INCLUDE APPLYING MULCH AND ESTABLISHING VEGETATION, WATER SPRAYING, SURFACE ROUGHENING, APPLYING POLYMERS, SPRAY-ON TACKIFIERS, CHLORIDES, AND BARRIERS. SOME SITES MAY REQUIRE AN APPROACH THAT UTILIZES A COMBINATION OF MEASURES FOR DUST CONTROL. FOLLOW PROCEDURES FOUND IN WISCONSIN DNR TECHNICAL STANDARD 1068 (CURRENT EDITION). 6. THE USE, STORAGE, AND DISPOSAL OF CHEMICALS, CEMENT, AND OTHER COMPOUNDS AND MATERIALS USED ON SITE SHALL BE MANAGED DURING THE CONSTRUCTION PERIOD TO PREVENT THEIR TRANSPORT BY RUNOFF INTO WATERS OF THE STATE. 7. CONTRACTOR SHALL PROVIDE AN OPEN AGGREGATE CONCRETE TRUCK WASHOUT AREA ON SITE. CONTRACTOR TO ENSURE THAT CONCRETE WASHOUT SHALL BE CONTAINED TO THIS DESIGNATED AREA AND NOT BE ALLOWED TO RUN INTO STORM INLETS OR INTO THE OVERLAND STORMWATER DRAINAGE SYSTEM. WASHOUT AREA SHALL BE REMOVED UPON COMPLETION OF CONSTRUCTION. 8. TEMPORARY SITE RESTORATION SHALL TAKE PLACE IN DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE OR ON WHICH LAND DISTURBING ACTIVITIES WILL NOT BE PERFORMED FOR A PERIOD GREATER THAN 14 DAYS AND REQUIRES VEGETATIVE COVER FOR LESS THAN ONE YEAR. THIS TEMPORARY SITE RESTORATION REQUIREMENT ALSO APPLIES TO SOIL STOCKPILES THAT EXIST FOR MORE THAN 7 DAYS. PERMANENT RESTORATION APPLIES TO AREAS WHERE PERENNIAL VEGETATIVE COVER IS NEEDED TO PERMANENTLY STABILIZE AREAS OF EXPOSED SOIL. PERMANENT STABILIZATION SHALL OCCUR WITHIN 3 WORKING DAYS OF FINAL GRADING. TOPSOIL, SEED, AND MULCH SHALL BE IN GENERAL CONFORMANCE WITH TECHNICAL STANDARDS 1058 AND 1059 AND SHALL MEET THE SPECIFICATIONS FOUND IN THE LANDSCAPING AND SITE STABILIZATION SECTION OF THIS CONSTRUCTION DOCUMENT. ANY SOIL EROSION THAT OCCURS AFTER FINAL GRADING AND/OR FINAL STABILIZATION MUST BE REPAIRED AND THE STABILIZATION WORK REDONE. 9. IF SITE DEWATERING IS REQUIRED FOR PROPOSED CONSTRUCTION ACTIVITIES, ALL SEDIMENT LADEN WATER GENERATED DURING THE DEWATERING PROCESS SHALL BE TREATED TO REMOVE SEDIMENT PRIOR TO DISCHARGING OFF-SITE OR TO WATERS OF THE STATE. FOLLOW ALL PROCEDURES FOUND IN TECHNICAL STANDARD 1061. 10. ALL OFF-SITE SEDIMENT DEPOSITS OCCURRING AS A RESULT OF CONSTRUCTION WORK OR A STORM EVENT SHALL BE CLEANED UP BY THE END OF EACH WORKING DAY. DUST CONTROL REQUIREMENTS SHALL BE FOLLOWED PER WI DNR TECHNICAL STANDARD 1068 (CURRENT EDITION). FLUSHING SHALL NOT BE ALLOWED. C. ALL EROSION CONTROL DEVICES SHALL AT A MINIMUM BE INSPECTED EVERY 7 CALENDAR DAYS OR EVERY 14 DAYS AND WITHIN 24 HOURS OF THE END OF A RAIN EVENT OF 0.5" OR MORE. MAINTENANCE SHALL BE PERFORMED PER WISCONSIN ADMINISTRATIVE CODE (W.A.C.) NR 151 STORMWATER MANAGEMENT TECHNICAL STANDARD REQUIREMENTS. D. EROSION CONTROL MEASURES SHALL NOT BE REMOVED UNTIL THE AREA(S) SERVED HAVE ESTABLISHED VEGETATIVE COVER. E. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL EROSION CONTROL PERMITS. DIVISION 32 EXTERIOR IMPROVEMENTS 32 10 00 AGGREGATE BASE & ASPHALT PAVEMENT A. CONTRACTOR TO PROVIDE COMPACTED AGGREGATE BASE AND HOT MIX ASPHALT PAVEMENT WHERE INDICATED ON THE PLANS. ALL AGGREGATE PROVIDED MUST COMPLY WITH SECTION 305 OF THE WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. PROVIDE HOT MIX ASPHALT MIXTURE TYPES PER SECTION 460 OF THE WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. CONTRACTOR SHALL OBTAIN AND REVIEW SOILS REPORT FOR RECOMMENDATIONS FOR GEO-GRID / GEOTEXTILE BELOW CRUSHED AGGREGATE (IF APPLICABLE). CONTRACTOR TO PROVIDE AGGREGATE BASE AND HOT MIX ASPHALT PAVEMENT TYPES AND DEPTHS AS INDICATED BELOW: STANDARD ASPHALT PAVING SECTION HEAVY ASPHALT PAVING SECTION 1-1/2” SURFACE COURSE (5 LT 58-28S) 1-1/2” SURFACE COURSE (5 LT 58-28S) (WISDOT 455.2.5 TACK COAT (STAGED PAVING) WISDOT 455.2.5 TACK COAT (STAGED PAVING) 2” BINDER COURSE (4 LT 58-28S) 2-1/2” BINDER COURSE (4 LT 58-28S) 10” OF 1-1/4” CRUSHED AGGREGATE 12” OF 1-1/4” CRUSHED AGGREGATE B. CONTRACTOR TO COMPACT THE AGGREGATE BASE, ASPHALT BINDER COURSE, AND ASPHALT SURFACE COURSE TO AN AVERAGE DENSITY PER WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. ALL ASPHALT PAVEMENT AREAS SHALL BE PAVED TO WITHIN 0.05' OF DESIGN SURFACE GRADES WITH POSITIVE DRAINAGE BEING MAINTAINED IN ACCORDANCE WITH DESIGN PLANS. A MINIMUM OF 1.5% SLOPE SHALL BE MAINTAINED IN ALL ASPHALT PAVEMENT AREA. C. GRANULAR BASE MATERIAL SHALL BE PROOF-ROLLED AND INSPECTED PRIOR TO PAVING UNDER SUPERVISION OF GEOTECHNICAL TESTING AGENCY. UNDERCUT & REPAIR UNSUITABLE AREAS PER GEOTECHNICAL RECOMMENDATIONS. D. HOT MIX ASPHALT CONSTRUCTION TO BE PROVIDED PER MORE STRINGENT REQUIREMENTS OF GEOTECHNICAL REPORT OR CONSTRUCTION DOCUMENTS. E. CONTRACTOR TO PROVIDE 4” WIDE YELLOW PAINTED STRIPING FOR PARKING STALLS, TRAFFIC LANES, AND NO PARKING AREAS. YELLOWM PAINT MARKINGS SHALL ALSO BE PROVIDED FOR H.C. ACCESSIBLE SYMBOLS, TRAFFIC ARROWS, AND TRAFFIC MESSAGES. 32 20 00 CONCRETE AND AGGREGATE BASE A. CONTRACTOR TO PROVIDE CRUSHED AGGREGATE BASE AND CONCRETE WHERE INDICATED ON THE PLANS. B. ALL AGGREGATE PROVIDED MUST COMPLY WITH SECTION 305 OF THE WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. ALL AGGREGATE PLACED MUST BE COMPACTED TO AN AVERAGE DENSITY PER WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. C. DESIGN AND CONSTRUCTION OF ALL CAST-IN-PLACE EXTERIOR CONCRETE FLAT WORK SHALL CONFORM TO ACI 330R-08 & ACI 318-08. D. EXTERIOR CONCRETE FLAT WORK CONSTRUCTION TO BE PROVIDED PER MORE STRINGENT REQUIREMENTS OF THE GEOTECHNICAL REPORT OR THIS SPECIFICATION. CONCRETE FLAT WORK CONSTRUCTION IS AS FOLLOWS: 1. SIDEWALK CONCRETE - 4” OF CONCRETE OVER 4” OF 3/4” CRUSHED AGGREGATE BASE. CONTRACTION JOINTS SHALL CONSIST OF 1/8” WIDE BY 1” DEEP TOOLED JOINT WHERE INDICATED ON THE PLANS. 2. STANDARD CONCRETE (PASSENGER CAR TRAFFIC) - 6” OF CONCRETE OVER 4” OF 3/4” CRUSHED AGGREGATE. CONTRACTION JOINTS SHALL BE SAWCUT 1.5” IN DEPTH AND BE SPACED A MAXIMUM OF 12.5' ON CENTER a. CONCRETE SHALL BE STEEL REINFORCED AS FOLLOWS: 1) TIE BARS AT OUTERMOST CONTRACTION JOINT (FIRST JOINT FROM EDGE OR AT CURB JOINT) AROUND PERIMETER OF CONCRETE. TIE BARS SHALL BE #4 REBAR 24” LONG PLACED AT 30” O.C. 2) TYPICAL POUR CONTROL JOINT - POUR CONTROL JOINT SHALL BE PROVIDED WITH 1/4” X 4-1/2” X 4-1/4” DIAMOND SHAPED TAPERED PLATE DOWELS MANUFACTURED PER ASTM A36. INSTALL PER MANUFACTURERS SPECIFICATIONS. 1. DUMPSTER PAD/APRON CONCRETE - 8” OF CONCRETE OVER 6” OF AGGREGATE BASE. a. CONCRETE SHALL BE STEEL REINFORCED WITH THE FOLLOWING AND PLACED IN THE UPPER 1/3 TO ½ OF THE SLAB: 1) TIE BARS AT ALL CONTRACTION JOINTS OF THE CONCRETE. TIE BARS SHALL BE #4 REBAR 30” LONG PLACED AT 30” O.C. b. DUMPSTER PAD CONCRETE JOINTING SHALL BE AS FOLLOWS: 1) CONTRACTION SAWCUT JOINT - CONTRACTOR SHALL PROVIDE A SAWCUT JOINT AT MAXIMUM SPACING OF 15' ON CENTER. SAWCUT SHALL BE 2” IN DEPTH. 2) TYPICAL POUR CONTROL JOINT - POUR CONTROL JOINT SHALL BE PROVIDED WITH 1-1/4” DIAMETER BY 20” LONG SMOOTH DOWEL PLACED AT 12” O.C. ONE HALF OF THE DOWEL SHALL BE GREASED. GREENSTREAK 9” SPEED DOWEL TUBES SHALL BE USED. E. DESIGN MIXES SHALL BE IN ACCORDANCE WITH ASTM C94 1. STRENGTH TO BE MINIMUM OF 4,500 PSI AT 28 DAYS FOR EXTERIOR CONCRETE. 2. MAXIMUM WATER/CEMENT RATIO SHALL BE 0.45. 3. SLUMP SHALL NOT EXCEED 4” FOR EXTERIOR CONCRETE FLAT WORK 4. SLUMP SHALL BE 2.5” OR LESS FOR SLIP-FORMED CURB AND GUTTER 5. SLUMP SHALL BE BETWEEN 1.5” TO 3” FOR NON SLIP-FORMED CURB AND GUTTER. 6. ALL EXTERIOR CONCRETE SHALL BE AIR ENTRAINED WITH 4% TO 7% AIR CONTENT. NO OTHER ADMIXTURES SHALL BE USED WITHOUT APPROVAL OF EXCEL ENGINEERING, INC. CALCIUM CHLORIDE SHALL NOT BE USED. 7. MAXIMUM AGGREGATE SIZE FOR ALL EXTERIOR CONCRETE SHALL BE 0.75 INCHES. F. VERIFY EQUIPMENT CONCRETE PAD SIZES WITH CONTRACTOR REQUIRING PAD. PADS SHALL HAVE FIBERMESH 300 FIBERS AT A RATE OF 1.5 LBS/CU. YD. OR 6 X 6-W1.4 X W1.4 WELDED WIRE MESH WITH MINIMUM 1 INCH COVER. EQUIPMENT PADS SHALL BE 5.5 INCHES THICK WITH 1 INCH CHAMFER UNLESS SPECIFIED OTHERWISE. CONCRETE SHALL BE PROVIDED ON 6” OF 3/4” CRUSHED AGGREGATE BASE. COORDINATE ADDITIONAL PAD REQUIREMENTS WITH RESPECTIVE CONTRACTOR. G. ALL CONCRETE FLAT WORK SURFACES AND CONCRETE CURB FLOWLINES SHALL BE CONSTRUCTED TO WITHIN 0.05' OF DESIGN SURFACE AND FLOWLINE GRADES ASSUMING POSITIVE DRAINAGE IS MAINTAINED IN ACCORDANCE WITH THE DESIGN PLANS. H. CONCRETE FLAT WORK SHALL HAVE CONSTRUCTION JOINTS OR SAW CUT JOINTS PLACED AS INDICATED ON THE PLANS OR PER THIS SPECIFICATION. SAWCUTS SHALL BE DONE AS SOON AS POSSIBLE, BUT NO LATER THAN 24 HOURS AFTER CONCRETE IS PLACED. CONCRETE CURB AND GUTTER JOINTING SHALL BE PLACED EVERY 10' OR CLOSER (6' MIN.). IF CONCRETE PAVEMENT IS ADJACENT TO CONCRETE CURB, JOINTING IN THE PAVEMENT AND CURB SHALL ALIGN. ALL EXTERIOR CONCRETE SHALL HAVE A BROOM FINISH UNLESS NOTED OTHERWISE. A UNIFORM COAT OF A HIGH SOLIDS CURING COMPOUND MEETING ASTM C309 SHALL BE APPLIED TO ALL EXPOSED CONCRETE SURFACES. ALL CONCRETE IS TO BE CURED FOR 7 DAYS. EXTERIOR CONCRETE SHALL BE SEPARATED FROM BUILDINGS WITH CONTINUOUS 0.5 INCH FIBER EXPANSION JOINT AND/OR 0.25 INCH FIBER EXPANSION JOINT AT DECORATIVE MASONRY UNITS. I. ALL REINFORCING BARS SHALL BE ASTM A615 GRADE 60. THICKNESS OF CONCRETE COVER OVER REINFORCEMENT SHALL BE NOT LESS THAN 3” WHERE CONCRETE IS DEPOSITED AGAINST THE GROUND WITHOUT THE USE OF FORMS AND NOT LESS THAN 1.5” FOR UP TO #5 BARS AND 2” FOR #6 TO #10 BARS IN ALL OTHER LOCATIONS. ALL REINFORCING SHALL BE LAPPED 48 DIAMETERS FOR UP TO #6 BARS, 62 DIAMETERS FOR #7 TO #9 BARS, 68 DIAMETERS FOR #10 BARS OR AS NOTED ON THE DRAWINGS AND EXTENDED AROUND CORNERS WITH CORNER BARS. PLACING AND DETAILING OF STEEL REINFORCING AND REINFORCING SUPPORTS SHALL BE IN ACCORDANCE WITH CRSI AND ACI MANUAL AND STANDARD PRACTICES. THE REINFORCEMENT SHALL NOT BE PAINTED AND MUST BE FREE OF GREASE/OIL, DIRT OR DEEP RUST WHEN PLACED IN THE WORK. ALL WELDED WIRE FABRIC SHALL MEET THE REQUIREMENTS OF ASTM A 1064. WELDED WIRE FABRIC SHALL BE PLACED 2” FROM TOP OF SLAB, UNLESS INDICATED OTHERWISE. J. CONTRACTOR SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO SAMPLE MATERIALS, PERFORM TESTS, AND SUBMIT TEST REPORTS DURING CONCRETE PLACEMENT. TESTS WILL BE PERFORMED ACCORDING TO ACI 301. CAST AND LABORATORY CURE ONE SET OF FOUR STANDARD CYLINDERS FOR EACH COMPOSITE SAMPLE FOR EACH DAY'S POUR OF EACH CONCRETE MIX EXCEEDING 5 CU. YD., BUT LESS THAN 25 CU. YD., PLUS ONE SET FOR EACH ADDITIONAL 50 CU. YD. OR FRACTION THEREOF. PERFORM COMPRESSIVE-STRENGTH TESTS ACCORDING TO ASTM C 39. TEST TWO SPECIMENS AT 7 DAYS AND TWO SPECIMENS AT 28 DAYS. PERFORM SLUMP TESTING ACCORDING TO ASTM C 143. PROVIDE ONE TEST AT POINT OF PLACEMENT FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH CONCRETE MIX. PERFORM ADDITIONAL TESTS WHEN CONCRETE CONSISTENCY APPEARS TO CHANGE. K. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. IN HOT, DRY, AND WINDY WEATHER, APPLY AN EVAPORATION-CONTROL COMPOUND ACCORDING TO MANUFACTURER'S INSTRUCTIONS AFTER SCREEDING AND BULL FLOATING, BUT BEFORE POWER FLOATING AND TROWELLING. L. LIMIT MAXIMUM WATER-CEMENTITIOUS RATIO OF CONCRETE EXPOSED TO FREEZING, THAWING AND DEICING SALTS TO 0.45. M. TEST RESULTS WILL BE REPORTED IN WRITING TO THE DESIGN ENGINEER, READY-MIX PRODUCER, AND CONTRACTOR WITHIN 24 HOURS AFTER TESTS. REPORTS OF COMPRESSIVE STRENGTH TESTS SHALL CONTAIN THE PROJECT IDENTIFICATION NAME AND NUMBER, DATE OF CONCRETE PLACEMENT, NAME OF CONCRETE TESTING SERVICE, CONCRETE TYPE AND CLASS, LOCATION OF CONCRETE BATCH ON SITE, DESIGN COMPRESSIVE STRENGTH AT 28 DAYS, CONCRETE MIX PROPORTIONS AND MATERIALS, COMPRESSIVE BREAKING STRENGTH, AND TYPE OF BREAK FOR BOTH 7-DAY TESTS AND 28-DAY TESTS. 32 30 00 LANDSCAPING AND SITE STABILIZATION A. TOPSOIL: CONTRACTOR TO PROVIDE A MINIMUM OF 6” OF TOPSOIL FOR ALL DISTURBED OPEN AREAS, OTHER THAN A LANDSCAPE ISLANDS, WHICH SHALL BE PROVIDED WITH A MINIMUM OF 10” OF TOPSOIL. REUSE SURFACE SOIL STOCKPILED ON SITE AND SUPPLEMENT WITH IMPORTED OR MANUFACTURED TOPSOIL FROM OFF SITE SOURCES WHEN QUANTITIES ARE INSUFFICIENT. EXCAVATOR SHALL BE RESPONSIBLE FOR ROUGH PLACEMENT OF TOPSOIL TO WITHIN 1” OF FINAL GRADE PRIOR TO LANDSCAPER FINAL GRADING. LANDSCAPER TO PROVIDE PULVERIZING AND FINAL GRADING OF TOPSOIL. PROVIDE SOIL ANALYSIS BY A QUALIFIED SOIL TESTING LABORATORY AS REQUIRED TO VERIFY THE SUITABILITY OF SOIL TO BE USED AS TOPSOIL AND TO DETERMINE THE NECESSARY SOIL AMENDMENTS. TEST SOIL FOR PRESENCE OF ATRAZINE AND INFORM EXCEL ENGINEERING, INC. IF PRESENT PRIOR TO BIDDING PROJECT. TOPSOIL SHALL HAVE A PH RANGE OF 5.5 TO 8, CONTAIN A MINIMUM OF 5 PERCENT ORGANIC MATERIAL CONTENT, AND SHALL BE FREE OF STONES 1 INCH OR LARGER IN DIAMETER. ALL MATERIALS HARMFUL TO PLANT GROWTH SHALL ALSO BE REMOVED. TOPSOIL INSTALLATION: LOOSEN SUBGRADE TO A MINIMUM DEPTH OF 6 INCHES AND REMOVE STONES LARGER THAN 1” IN DIAMETER. ALSO REMOVE ANY STICKS, ROOTS, RUBBISH, AND OTHER EXTRANEOUS MATTER AND DISPOSE OF THEM OFF THE PROPERTY. SPREAD TOPSOIL TO A DEPTH OF 6” BUT NOT LESS THAN WHAT IS REQUIRED TO MEET FINISHED GRADES AFTER LIGHT ROLLING AND NATURAL SETTLEMENT. DO NOT SPREAD TOPSOIL IF SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN 0.05 FEET OF FINISHED GRADE ELEVATION. B. SEEDED LAWNS: 1. PERMANENT LAWN AREAS SHALL BE SEEDED WITH THE FOLLOWING MIXTURE: 65% KENTUCKY BLUEGRASS BLEND (2.0-2.6 LBS./1,000 S.F.), 20% PERENNIAL RYEGRASS (0.6-0.8 LBS./1,000 S.F.), 15% FINE FESCUE (0.4-0.6 LBS/1,000 S.F.). STRAW AND MULCH SHALL BE LAID AT 100LBS/1,000 S.F. FERTILIZE AS PER SOIL TEST OR APPLY 5-10-10 OR EQUIVALENT AT 5-6 LBS/1,000 S.F. SEE EROSION MATTING SPECIFICATIONS AS REQUIRED. ALL SITE DISTURBED AREAS NOT DESIGNATED FOR OTHER LANDSCAPING AND SITE STABILIZATION METHODS SHALL BE SEEDED AS PERMANENT LAWN. NO BARE TOPSOIL SHALL BE LEFT ONSITE. FOLLOW PROCEDURES FOUND IN WDNR TECHNICAL STANDARDS 1058 & 1059. 2. ALL PERMANENT AND TEMPORARY STORM WATER CONVEYANCE SWALE BOTTOMS AND SIDE SLOPES SHALL BE SEEDED WITH THE FOLLOWING MIXTURE: 45% KENTUCKY BLUEGRASS (0.60 LBS./1000 S.F.), 40% CREEPING RED FESCUE (0.50 LBS./1,000 S.F.), AND 15% PERENNIAL RYEGRASS (0.20 LBS./1,000 S.F.). FERTILIZE AS PER SOIL TEST OR APPLY 5-10-10 OR EQUIVALENT AT 5-6 LBS./1,000 S.F. SEE EROSION MATTING SPECIFICATIONS AS REQUIRED. FOLLOW PROCEDURES FOUND IN WDNR TECHNICAL STANDARDS 1058 & 1059. 3. ALL TEMPORARY SEEDING SHALL CONSIST OF THE FOLLOWING MIXTURE: 100% RYEGRASS AT 1.9 LBS./1,000 S.F. STRAW AND MULCH SHALL BE LAID AT 100 LBS./1,000 S.F. FERTILIZE AS PER SOIL TEST OR APPLY 5-10-10 OR EQUIVALENT AT 5-6 LBS./1,000 S.F. SEE EROSION MATTING SPECIFICATIONS AS REQUIRED. FOLLOW PROCEDURES FOUND IN WDNR TECHNICAL STANDARDS 1058 & 1059. C. SEEDED LAWN MAINTENANCE: CONTRACTOR TO PROVIDE MAINTENANCE OF ALL LANDSCAPING FOR A PERIOD OF 90 DAYS FROM THE DATE OF INSTALLATION. AT THE END OF THE MAINTENANCE PERIOD, A HEALTHY, UNIFORM, CLOSE STAND OF GRASS SHOULD BE ESTABLISHED FREE OF WEEDS AND SURFACE IRREGULARITIES. LAWN COVERAGE SHOULD EXCEED 90% AND BARE SPOTS SHOULD NOT EXCEED 5”X5”. CONTRACTOR SHOULD REESTABLISH LAWNS THAT DO NOT COMPLY WITH THESE REQUIREMENTS AND CONTINUE MAINTENANCE UNTIL LAWNS ARE SATISFACTORY. D. TREES AND SHRUBS: FURNISH NURSERY-GROWN TREES AND SHRUBS WITH HEALTHY ROOT SYSTEMS DEVELOPED BY TRANSPLANTING OR ROOT PRUNING. PROVIDE WELL-SHAPED, FULLY BRANCHED, AND HEALTHY LOOKING STOCK. STOCK SHOULD ALSO BE FREE OF DISEASE, INSECTS, EGGS, LARVAE, AND DEFECTS SUCH AS KNOTS, SUN SCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT. SEE THE LANDSCAPE PLAN FOR SPECIFIC SPECIE TYPE, SIZE, AND LOCATION. E. TREE AND SHRUB INSTALLATION: EXCAVATE CIRCULAR PITS WITH SIDES SLOPED INWARD. TRIM BASE LEAVING CENTER AREA RAISED SLIGHTLY TO SUPPORT ROOT BALL. EXCAVATE PIT APPROXIMATELY THREE TIMES AS WIDE AS THE ROOT BALL DIAMETER. SET TREES AND SHRUBS PLUMB AND IN CENTER OF PIT WITH TOP OF BALL 1” ABOVE ADJACENT FINISHED GRADES. PLACE PLANTING SOIL MIX AROUND ROOT BALL IN LAYERS AND TAMP TO SETTLE MIX. WATER ALL PLANTS THOROUGHLY. PROVIDE TEMPORARY STAKING FOR TREES AS REQUIRED. F. TREE AND SHRUB MAINTENANCE/WARRANTY: CONTRACTOR TO PROVIDE MAINTENANCE OF ALL LANDSCAPING FOR A PERIOD OF 90 DAYS FROM THE DATE OF INSTALLATION. MAINTENANCE TO INCLUDE REGULAR WATERING AS REQUIRED FOR SUCCESSFUL PLANT ESTABLISHMENT. CONTRACTOR TO PROVIDE 1 YEAR WARRANTY ON ALL TREES, SHRUBS, AND PERENNIALS. G. DECORATIVE STONE: PROVIDE 3” MINIMUM THICK BLANKET OF 1.5” MINIMUM TO 2.5” MAXIMUM DECORATIVE STONE AT ALL PLANTING AREAS INDICATED ON THE LANDSCAPE PLAN. INSTALL OVER NON-WOVEN WEED BARRIER FABRIC. COLOR BY OWNER. H. ALUMINUM EDGING: INSTALL PERMALOC CLEANLINE LANDSCAPE EDGING TO SEPARATE ALL PLANTING BEDS FROM LAWN AREAS. EDGING TO BE CL 1/8”X4” WITH 12” LONG ALUMINUM STAKES. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. COLOR BY OWNER. I. LANDSCAPE AND LAWN IRRIGATION: CONTRACTOR TO PROVIDE DESIGN AND INSTALLATION OF IRRIGATION SYSTEM PIPING, VALVES, VALVE BOXES, SPRINKLERS, EMITTERS, DRIP TUBES, AND CONTROLS IN COMBINATIONS THAT BEST SUIT THE LANDSCAPE PLAN LAYOUT. ALL LAWN AND LANDSCAPING AREAS SHALL BE PROVIDED WITH IRRIGATION AS DELINEATED ON THE PLAN. THE DESIGN SHOULD MINIMIZE THE AMOUNT OF WATER THAT EXTENDS BEYOND THE PROPERTY AND ON PAVED AREAS. THE SYSTEM SHALL BE DESIGNED FOR FULLY AUTOMATIC OPERATION AND PROVIDE ALL NECESSARY CONTROLS, VALVES, AND WIRING TO OPERATE THE SYSTEM. THE CONTROL UNIT SHALL BE INSTALLED IN A MECHANICAL ROOM OR AT A LOCATION AGREED TO WITH THE OWNER. THE CONTROL UNIT SHOULD BE PROVIDED WITH A LOCKING COVER. DIVISION 33 UTILITIES 33 10 00 SITE UTILITIES A. CONTRACTOR TO FIELD VERIFY ALL EXISTING UNDERGROUND UTILITIES ON SITE. CONTRACTOR TO VERIFY PIPE LOCATIONS, SIZES, AND DEPTHS AT POINT OF PROPOSED CONNECTIONS AND VERIFY PROPOSED UTILITY ROUTES ARE CLEAR (PER CODE) OF ALL EXISTING UTILITIES AND OTHER OBSTRUCTIONS PRIOR TO CONSTRUCTION. COSTS INCURRED FOR FAILURE TO DO SO SHALL BE THE CONTRACTORS RESPONSIBILITY. B. CONTRACTOR TO FIELD TELEVISE ALL EXISTING SANITARY AND STORM LATERALS THAT ARE SCHEDULED TO BE RE-USED AND/OR CONNECTED TO ON SITE. THE TELEVISING SHALL BE COMPLETED TO ENSURE THE EXISTING LATERAL(S) ARE FREE OF OBSTRUCTIONS AND IN SOUND STRUCTURAL CONDITION. TELEVISING OF THESE LATERAL(S) SHOULD BE COMPLETED AT BEGINNING OF CONSTRUCTION AND DESIGN ENGINEER SHALL BE NOTIFIED OF ANY PIPE OBSTRUCTIONS AND/OR STRUCTURAL DEFICIENCIES IMMEDIATELY AFTER COMPLETION OF FIELD TELEVISING. INSPECT ALL STORM AND SANITARY STRUCTURES TO CONFIRM STRUCTURES ARE STRUCTURALLY SOUND AND IN WORKING ORDER. NOTIFY DESIGN ENGINEER OF INADEQUATE STRUCTURES. C. ALL SANITARY PIPE SHALL BE IN ACCORDANCE WITH MATERIALS SPECIFIED IN TABLE A: ALLOWABLE PIPE MATERIAL SCHEDULE. ALL SANITARY PIPE BELOW PROPOSED & FUTURE BUILDINGS SHALL BE IN ACCORDANCE WITH MATERIALS SPECIFIED IN TABLE A: ALLOWABLE PIPE MATERIAL. INSULATION SHALL BE PROVIDED PER STATE PLUMBING CODES AS NECESSARY BASED ON PROPOSED DEPTH PER PLANS. D. SANITARY MANHOLES SHALL BE 48” PRECAST AND CONFORM TO THE STANDARD SPECIFICATIONS FOR SEWER & WATER CONSTRUCTION IN WISCONSIN-CURRENT EDITION UNLESS OTHERWISE DIRECTED BY THE ENGINEER. SANITARY MANHOLE FRAME AND GRATE TO BE NEENAH R-1550-A OR EQUAL. RIM ELEVATION TO BE SET AT FINISHED GRADE IN DEVELOPED AREAS AND 12” ABOVE FINISHED GRADE IN UNDEVELOPED AREAS EXCEPT AS OTHERWISE DIRECTED BY THE ENGINEER. E. CLEANOUTS SHALL BE PROVIDED FOR THE SANITARY & STORM SERVICES AT LOCATIONS INDICATED ON THE UTILITY PLAN. THE CLEANOUT SHALL CONSIST OF A COMBINATION WYE FITTING IN LINE WITH THE SANITARY/STORM SERVICE WITH THE CLEANOUT LEG OF THE COMBINATION WYE FACING STRAIGHT UP. THE CLEANOUT SHALL CONSIST OF A (4” OR 6”) VERTICAL PVC PIPE WITH A WATER TIGHT REMOVABLE CLEANOUT PLUG. AN 8” PVC FROST SLEEVE SHALL BE PROVIDED. THE BOTTOM OF THE FROST SLEEVE SHALL TERMINATE 12” ABOVE THE TOP OF THE SANITARY LATERAL OR AT LEAST 6” BELOW THE PREDICTED FROST DEPTH, WHICHEVER IS SHALLOWER. THE CLEANOUT SHALL EXTEND JUST ABOVE THE SURFACE GRADE IN LAWN OR LANDSCAPE AREAS WITH THE FROST SLEEVE TERMINATING AT THE GRADE SURFACE. THE CLEANOUT SHALL EXTEND TO 4 INCHES BELOW SURFACE GRADE IN PAVED SURFACES WITH A ZURN (Z-1474-N) HEAVY DUTY CLEANOUT HOUSING PLACED OVER THE TOP OF THE CLEANOUT FLUSH WITH THE SURFACE GRADE. IN PAVED SURFACES, THE FROST SLEEVE SHALL TERMINATE IN A CONCRETE PAD AT LEAST 6” THICK AND EXTENDING AT LEAST 9” FROM THE SLEEVE ON ALL SIDES, SLOPING AWAY FROM THE SLEEVE. THE CLEANOUT HOUSING SHALL BE CONSTRUCTED PER MANUFACTURERS REQUIREMENTS. F. ALL PROPOSED WATER PIPE SHALL BE IN ACCORDANCE WITH MATERIALS SPECIFIED IN TABLE A: ALLOWABLE PIPE MATERIAL SCHEDULE. 6' MINIMUM COVER SHALL BE PROVIDED OVER ALL WATER PIPING UNLESS OTHERWISE SPECIFIED. G. ALL PROPOSED STORM PIPE SHALL BE IN ACCORDANCE WITH MATERIALS SPECIFIED IN TABLE A: ALLOWABLE PIPE MATERIAL SCHEDULE. ALL PROPOSED STORM PIPE BELOW BUILDINGS SHALL BE IN ACCORDANCE WITH MATERIALS SPECIFIED IN TABLE A: ALLOWABLE PIPE MATERIAL SCHEDULE. SEE UTILITY PLANS FOR ALL STORM PIPE MATERIAL TYPES TO BE USED. PIPE SHALL BE PLACED MIN. 8' HORIZONTALLY FROM FOUNDATION WALLS. H. SANITARY, STORM, AND WATER UTILITY PIPE INVERTS SHALL BE CONSTRUCTED WITHIN 0.10' OF DESIGN INVERT ELEVATIONS ASSUMING PIPE SLOPE AND SEPARATION IS MAINTAINED PER THE UTILITY DESIGN PLANS AND STATE REQUIREMENTS. I. SITE UTILITY CONTRACTOR SHALL RUN SANITARY SERVICE TO A POINT WHICH IS A MAXIMUM OF 5' FROM THE EXTERIOR WALL OF THE FOUNDATION. SITE UTILITY CONTRACTOR SHALL RUN STORM SEWER FOR INTERNALLY DRAINED BUILDINGS TO A POINT WHICH IS A MAXIMUM OF 5' FROM THE EXTERIOR WALL OF THE FOUNDATION. SITE UTILITY CONTRACTOR SHALL RUN DOWNSPOUT LEADS TO BUILDING FOUNDATION AND UP 6” ABOVE SURFACE GRADE FOR CONNECTION TO DOWNSPOUT FOR ALL DOWNSPOUT TO RISER (DSR) CONNECTIONS. DOWNSPOUTS TO GRADE (DSG) SHALL BE PROVIDED WITH SPLASH BLOCKS AT THE DISCHARGE LOCATION. ALL DOWNSPOUT LOCATIONS SHOULD BE VERIFIED WITH ARCHITECTURAL PLANS AND DOWNSPOUT CONTRACTOR/GC PRIOR TO INSTALLATION OF DOWNSPOUT LEADS. DOWNSPOUT LEADS SHALL NOT UNDERMINE BUILDING FOUNDATIONS. SITE UTILITY CONTRACTOR SHALL RUN WATER SERVICE TO A POINT WITHIN THE FOUNDATION SPECIFIED BY THE PLUMBING PLANS. CONTRACTOR TO CUT AND CAP WATER SERVICE 12” ABOVE FINISHED FLOOR ELEVATION. J. ALL UTILITIES SHALL BE INSTALLED WITH PLASTIC COATED TRACER WIRE (10 TO 14 GAUGE SOLID COPPER, OR COPPER COATED STEEL WIRE). PLASTIC WIRE MAY BE TAPED TO PLASTIC WATER OR SEWER PIPE. IF ATTACHED, THE TRACER WIRE SHALL BE SECURED EVERY 6 TO 20 FEET AND AT ALL BENDS. TRACER WIRE SHALL HAVE ACCESS POINTS AT LEAST EVERY 300 FEET. TRACER WIRE SHALL TERMINATE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS AT GRADE OR IN TERMINATION BOX PER LOCAL/STATE REQUIREMENTS. K. ALL UTILITIES SHALL BE INSTALLED PER STATE, LOCAL, AND INDUSTRY STANDARDS. WATER, SANITARY, AND STORM SEWER SHALL BE INSTALLED PER "STANDARD SPECIFICATION FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN". THE EXCEL ENGINEERING DESIGN ENGINEER SHALL BE RESPONSIBLE FOR OBTAINING STATE PLUMBING REVIEW APPROVAL (IF REQUIRED). THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL OTHER PERMITS REQUIRED TO INSTALL WATER, SANITARY AND STORM SEWER. L. SEE PLANS FOR ALL OTHER UTILITY SPECIFICATIONS AND DETAILS. TABLE A: ALLOWABLE PIPE MATERIAL SCHEDULE Utility Material Pipe Code Fitting Code Joint Code Combined Domestic/Fire Service C900 PVC AWWA C900, ASTM D1785, ASTM D2241 AWWA C110, AWWA C153, ASTM D2464, ASTM D2466, ASTM D2467, ASTM D3311, ASTM F409, ASTM F1336, ASTM F1866 Joint: ASTM D3139 Integral Bell & Spigot Elastomeric Seal: ASTM F477 Sanitary Sewer SDR 35 PVC ASTM D1785, ASTM D2665, ASTM D3034 ASTM F1336 Push On: ASTM D3212 for Tightness Elastomeric Gasket: ASTM F477 Storm Sewer HDPE ASTM F2648, ASTM F2306, AASHTO M252, TYPE S (4 IN - 10 IN), AASHTO M294, TYPE S (12 IN - 60 IN) ASTM F2648, ASTM F2306, AASHTO M252, or AASHTO M294 Joint: ASTM F2648, ASTM F2306, AASHTO M252, or AASHTO M294 Elastomeric Seal: ASTM F477 Storm Sewer SDR 35 PVC ASTM D1785, ASTM D2665, ASTM D3034 ASTM F1336 Push On: ASTM D3212 for Tightness Elastomeric Seal: ASTM F477 Page 25 of 36 AA A AA AA AA AAAAAA A AA A BBBBBBBBBBB B BB BB BBBB BB B C D D D D F GG G HH FF J J JJ K L L L M K NN N NN OO O O P Q N S SSSSSSSSSSSS SS F F U VVVV VVV VVVV V V V V V X X Y V V V Z AA CCCC BB BB BB W DD BB Y Z D D D EEEE EE EE FF FF FF FF B SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C1.0 CIVIL EXISTING SITE AND DEMOLITION PLAN IFA OCT. 1, 2026 30' 0 30' 60' SCALE: 1"= 30' SAWCUT AND REMOVE PAVEMENT, STONE BASE TO REMAIN SAWCUT AND REMOVE CONCRETE RAZE PORTION OF BUILDING AND ASSOCIATED FEATURES. (SEE ARCH PLANS FOR MORE DETAILS) LEGEND: NORTH KEYNOTES REMOVE PORTION OF CURB. SAWCUT AS NECESSARY REMOVE TREE/SHRUB.. SEE SHEET C1.4. REMOVE AND REINSTALL MAILBOX IN TEMPORARY LOCATION ON SITE DURING THE DURATION OF CONSTRUCTION. REINSTALL IN CURRENT LOCATION AFTER COMPLETION OF SITE WORK. REMOVE LIGHTPOLE AND ELECTRICAL CONDUITS PROTECT EXISTING INLET STRUCTURE. FRAME AND GRATE TO BE REMOVED AND REPLACED. SEE C1.3 FOR DETAILS REMOVE HANDICAPPED SIGN. REUSE IF POSSIBLE. COORDINATE WITH OWNER. PROTECT COLUMNS REMOVE FENCE AND FENCE MOUNTED LIGHTS W/ CONDUITS REMOVE STORM INLET AND ASSOCIATED PIPING. REMOVE YARD INLET AND ANY ASSOCIATED PIPING. PROTECT STORM MANHOLE REMOVE BOLLARD PROTECT BOLLARD PROTECT FP WHEEL VALE REMOVE TRANSFORMER AND TRANSFORMER PAD REMOVE DOWNSPOUT CONNECTION. CAP & ABANDON EXISTING PIPE. REMOVE CONCRETE FLUME PROTECT UTILITY LINE REMOVE EXISTING COMPACTOR REMOVE PORTION OF SANITARY LINE REMOVE PORTION OF WATERLINE. TURN OFF EXISTING WASTER SERVICE AT CORP STOP. REMOVE STORM LINE PRIOR TO CONSTRUCTION CONTRACTOR TO FIELD VERIFY WHAT 6" PLATE IS USED FOR. COORDINATE WITH OWNER/ENGINEER IF IT CAN'T BE REMOVED. REMOVE AND REPLACE DOOR. SEE ARCH PLANS FOR DETAILS REMOVE AND REPLACE OVERHEAD DOOR. SEE ARCH PLANS FOR DETAILS REMOVE AND REPLACE GAS METER. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY. FLUSH/CLEAN EXISTING STORM PIPE TO REMOVE SEDIMENT & GRAVEL DEPOSITS. LOCATION OF APPARENT STORM PIPE DEFORMITY OR DAMAGE PER STORM SEWER TELEVISING. CONTRACTOR TO UNCOVER/INSPECT EXISTING STORM SEWER AND MAKE NECESSARY REPAIRS TO PIPE/ PIPE JOINT OR CONNECTION AS NECESSARY. IF REQUIRED, PROVIDE NEW PIPE SEGMENT & JOINTS. SAWCUT AND REMOVE EXISTING ASPHALT PAVEMENT & CURB & GUTTER AS NECESSARY. CONTRACTOR/OWNER TO COORDINATE WORK WITH OWNER'S ASSOCIATION AS NEEDED. A B C D F G H J K L M N O P Q S U V W X Y Z AA BB CC DD EE FF REMOVE ASPHALT PAVEMENT & BASE GENERAL NOTES: · SEE SHEET C1.4 FOR REQUIRED LANDSCAPE REMOVALS AND TRIMMING/PRUNING. · ALL STORM AND SANITARY STRUCTURES WITHIN THE PROJECT AREA THAT ARE SCHEDULED TO REMAIN SHALL BE INSPECTED BY SITE UTILITY CONTRACTOR TO ENSURE STRUCTURES ARE STRUCTURALLY SOUND AND IN WORKING CONDITION. NOTIFY DESIGN ENGINEER OF ANY INADEQUATE STRUCTURES REQUIRING REPAIR OR REPLACEMENT. · SEE PLAN FOR LOCATIONS WHERE EXISTING STORM SEWER IS TO BE CLEANED AND/OR INSPECTED FOR REPAIRS PER STORM SEWER TELEVISING REPORT. Page 26 of 36 PROPOSED VESTIBULE FOOTPRINT: 153 SF ARCH FF = 100.00 CIVIL FF = 808.10 PROPOSED ADDITION FOOTPRINT: 2139 SF ARCH FF = 100.00 CIVIL FF = 808.10 21 F-350 CrewCab DRW LWB 4x2F-350 CrewCab DRW LWB 4x2F-350 CrewCab DRW LWB 4x2 15' PAVEMENT SETBACK 15' PAVEMENT SETBACK 50' BUILDING SETBACK 20' BUILDING SETBACK 50' BUILDING SETBACK 10 7 7 7 7 25 21 STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 10101010 10 10 10 10 10 10 10 10 10 10 10 STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 1 1 1 1 2 3 3 44 5 6 66 6666 19 19 1919 6 19 6 1919 19 6 6 6 66 6 7 7 8 8 99 99 99 9 10 11 1212 12 12121212121212 13 13 1313 13 13 13 1414 1414 14141414 1414 1414 14 14 14 15 16 16 1616 17 23 23 18 5 14 5 20 21 77 13 1 1 22 11 1111 1111 11 11 24 25 1111111111 2 2 24 26 26 8 8 8 8 888 13 13 13 13 13 13 13 13 13 13 13 13 13 13 8 6 6 66 6 6 6 666 13 27 27 28 28 29 29 25 25 25 28 26 26 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C1.1 CIVIL SITE PLAN IFA OCT. 1, 2026 30' 0 30' 60' SCALE: 1"= 30' NORTH PARKING: · PARKING PROVIDED: 255 SPACES (7) HANDICAP STALLS LEGEND: HATCH PAVEMENT SECTION STANDARD ASPHALT HEAVY DUTY ASPHALT SIDEWALK CONCRETE STANDARD CONCRETE DUMPSTER PAD / APRON CONCRETE ARTIFICIAL TURF PAINTED CROSSHATCH INVERTED CURB & GUTTER SHEDDING CURB & GUTTER KEYNOTES CONCRETE STOOP (SEE STRUCTURAL PLANS FOR DETAILS) RAISED WALK (SEE DETAIL) FLUSH WALK (SEE DETAIL) CONCRETE EQUIPMENT PAD. VERIFY PAD SIZE WITH CONTRACTOR REQUIRING PAD PRIOR TO CONSTRUCTION. CURB RAMP (SEE DETAIL) 18" CURB & GUTTER (SEE DETAIL) CURB TAPER (SEE DETAIL) HANDICAP SIGN PER STATE CODE (SEE DETAIL) HANDICAP STALL & STRIPING PER STATE CODES DUMPSTER ENCLOSURE (SEE ARCH PLANS FOR DETAILS) 6" CONCRETE BOLLARDS (TYP.). SEE DETAIL. PROVIDE YELLOW BOLLARD SLEEVE IN SMOOTH FINISH OVER EXISTING BOLLARD TRAFFIC FLOW ARROWS (TYP). COLOR TO MATCH PARKING STALL STRIPING PAINT STRIPING (TYP). COLOR TO MATCH PARKING STALL STRIPING BAG TOSS AREA 4' TALL PERIMETER FENCE. SEE ARCH PLANS. BUILDING CANOPY. SEE ARCH PLANS. DOG PARK AREA 24" CURB & GUTTER (SEE DETAIL) RELOCATED SIGN. SEE ELECTRICAL PLANS FOR FINAL CONNECTION/ROUTING SCREENING FENCE. SEE ARCH PLANS. PERGOLA COUNTERTOP WITH GRILL. SEE ARCH PLANS. BUILDING PERGOLA. SEE ARCH PLANS. BUILDING CANOPY COLUMN. SEE ARCH PLANS. 6" VERTICAL CURB (SEE DETAIL) TRANSITION CURB PAN WIDTH TO MATCH STREET CURB & GUTTER WIDTH. FLUSH OUT AT SIDEWALK TRANSITION. CONCRETE FLUME. (SEE DETAIL) 4' WIDE MAN-DOOR SWING GATE ON PERIMETER FENCE. REPLACE EXISTING ASPHALT PAVEMENT OR CONCRETE CURB AND GUTTER AS NECESSARY FOLLOWING STORM SEWER INVESTIGATION/REPAIRS. MATCH EXISTING. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Page 27 of 36 PROPOSED VESTIBULE FOOTPRINT: 153 SF ARCH FF = 100.00 CIVIL FF = 808.10 PROPOSED ADDITION FOOTPRINT: 2139 SF ARCH FF = 100.00 CIVIL FF = 808.10 21 10 7 7 7 7 25 21 STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 10101010 10 10 10 10 10 10 10 10 10 10 10 STAKEOUT INFORMATION: VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 808808 805 806 807 806 807 807 807 806 806 807 807 807 807 806 806 806 806 806 807 807 808 808 808809 808 808 808 808 RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE 808 EC 1 EC 1 EC 1 EC 1 EC 1 EC 1 EC 2 EC 3 EC 3 EC 3 EC 3EC 3 EC 3 EC 3 EC 3 EC 3 EC 3 EC 3 EC 4 807.90 TW 807.40 BW 807.80 TW EG 807.31 BW EG 807.25 TW 807.25 BW 807.25 TW 807.25 BW 807.67 TW 807.17 BW 807.69 TW 807.19 BW 807.69 TW 807.19 BW 807.71 TW 807.21 BW 807.80 TW 807.30 BW 807.74 TW 807.24 BW 807.66 TW 807.16 BW 807.83 TW 807.33 BW 807.43 TW 807.43 BW 807.93 TW 807.43 BW EG 803.75 EG 803.72 EG 803.23 EG 801.98 EG 807.96 EG 806.53 EG 806.38 EG 805.03 EG 805.09 EG 804.94 EG 804.85 EG 806.19 EG 806.88 EG 807.47 EG 807.38 EG 807.24 EG 807.27 EG 807.43 EG 807.36 EG 807.88 EG808.20 EG808.80 EG809.28 EG 809.77 EG 810.00 EG 807.60 EG 807.22 EG 807.89 EG 807.74 EG 805.35 805.53 804.78 806.39 806.30 806.39 806.49806.56 807.30 807.20 807.30 807.57 806.81 806.13 806.45806.95 806.88 806.29 806.58 806.68 807.03806.74 806.63 806.92 806.52 806.47 806.64 806.76 806.60 806.56 806.54 806.31 806.21806.39 806.52 806.22 806.50 806.75 806.53806.30 806.40 806.59 806.97 806.85 806.68 806.80 806.90 806.74 807.19 807.12 806.93806.99 807.06 807.01 806.82 806.99 806.70806.57 806.66 806.89 808.60 808.47 808.35 808.45 808.57 808.43 808.54 808.54 808.42808.46 808.49 808.47 808.37 808.19 808.11 808.27 808.32 808.11 808.03 807.90 807.80807.92 808.00 807.85 807.77 807.58 807.42807.65 807.70 807.49 806.51 806.40 806.31 806.38 806.49 806.58 806.62806.60 806.43 806.25 806.28 806.41 806.53 806.64806.76806.59 806.19 806.13 806.81 807.90 808.64 807.13 809.27 809.45 809.69 809.58 809.04 809.18 808.92 808.72 808.55 808.10 807.81 807.53 806.72 807.06 806.10 805.70 805.65805.65 805.75 805.90 806.05 806.20 806.35 806.45806.30 806.15 806.00 805.85 805.70 805.55 805.45805.45 805.45 805.75 806.00 806.25 806.50 806.60 806.65 805.70 806.73 807.00 806.50 806.71 806.05 807.32 808.59 808.58 808.79 807.68 807.60807.75 807.66 807.90 807.57 807.58 807.43 807.28 807.13 807.12 807.27 807.36 807.42 806.69 806.44 806.17 805.85 805.55 805.27 805.40 805.47 805.35805.73805.20 805.10 805.38 804.34 805.52 807.10 806.50 807.53807.50 808.00 808.00 808.32 808.25 808.48 808.30 808.00 808.10 808.00 808.10 807.61 808.10 808.10 808.10 808.10 808.10 808.00807.90 807.84 807.84 807.75 807.75 807.84 807.93 807.93 808.01 807.84 807.85 807.85 808.00 807.95 807.80 807.78 807.63 807.74 807.63 807.63 808.10 807.59 807.72 807.73 807.47 808.10807.87 808.10 808.10 808.00 807.75807.75 807.95807.93 807.93 807.50 808.07 EG 808.07 EG 807.15 807.93 EG 807.60 EG 807.84 EG 807.40 807.40807.75 TW 807.25 BW 807.75 TW 807.25 BW 807.90 TW 807.40 BW 807.90 TW 807.40 BW EG 807.90 807.90 807.97807.97 806 806 806 806 807 805 804 803 807 808.10 807.85 EG 807.85 EG 803.65 803.30802.40 807.83 TW 807.33 BW 807.38 807.88 807.93 806.10 805.70 806.65 805.70 805.80 809.10 808.75 808.25 808.70 808.90 809.10 RIDGE 808.75 808 807.90 808.15 RIDGE 808.00 807.10 807.93 TW 807.43 BW 807.43 TW 807.43 BW 807.60 807.73 TC 807.23 FL 807.79 TC 807.29 FL 807.85 TC 807.35 FL 807.67 TC 807.17 FL 807.12 TC 807.62 FL 808.02 TC 807.52 FL 808.30 TC 807.80 FL 807.72 RIDGE 807.50 807.82 807.74 TW 807.24 BW 807.90 807.82 807.74 TW 807.24 BW 807.90 807.82 807.74 TW 807.24 BW 807.82 807.90 807.69 TW 807.19 BW 807.75 807.75 806.60 806.40 806.15 806.80 807.40 807.48 807.35 807.45 807.93 805.65 805.25 806.85806.40 806 RIDGE SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C1.2 CIVIL GRADING AND EROSION CONTROL PLAN IFA OCT. 1, 2026 30' 0 30' 60' SCALE: 1"= 30' KEYNOTES SILT SOCK STABILIZED CONSTRUCTION ENTRANCE INLET PROTECTION CONCRETE WASHOUT EC 1 EC 2 EC 3 EC 4 GENERAL NOTES: · HANDICAP STALL AND ACCESS AISLES SHALL NOT EXCEED A SLOPE OF 1.50% IN ANY DIRECTION. HANDICAP STALL & ACCESS AISLES SHALL CONFORM TO ADA REQUIREMENTS (CURRENT EDITION) · ALL SIDEWALKS SHALL NOT EXCEED A MAXIMUM CROSS SLOPE OF 2.00% AND RUNNING SLOPE OF 4.50% UNLESS OTHERWISE SPECIFIED. · CONTRACTOR SHALL PROVIDE STABILIZED CONSTRUCTION ENTRANCE AT CONSTRUCTION ENTRANCE FOR PROPOSED IMPROVEMENTS AS REQUIRED PER CODE. · CONTRACTOR SHALL PROVIDE CONCRETE WASHOUT AS REQUIRED PER CODE. FINAL LOCATION TBD BY CONTRACTOR. · CONTRACTOR SHALL PROVIDE TEMPORARY INLET PROTECTION FOR ALL CURB INLETS & CATCH BASINS ONSITE & OFFSITE IMMEDIATELY DOWNSTREAM OF THE PROJECT SITE PER LOCAL CODE. NORTH Page 28 of 36 PROPOSED VESTIBULE FOOTPRINT: 153 SF ARCH FF = 100.00 CIVIL FF = 808.10 PROPOSED ADDITION FOOTPRINT: 2139 SF ARCH FF = 100.00 CIVIL FF = 808.10 21 10 7 7 7 7 25 21 STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 10101010 10 10 10 10 10 10 10 10 10 10 10 STAKEOUT INFORMATION: VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 808808 805 806 807 806 807 807 807 806 806 807 807 807 807 806 806 806 806 806 807 807 808 808 808809 808 808 808 808 LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS ELECTRICAL TRANSFORMER. C/T CABINET GENERATOR DOCKING STATION 200KW NATURAL GAS GENERATOR LIGHTED BOLLARD. LIGHTED BOLLARD REMOVE EXISTING CURB INLET FRAME AND GRATE. REPLACE WITH NEW NEENAH FOUNDRY R-3067 FRAME AND GRATE TYPE C. MATCH EXISTING RIM ELEVATION. CONTRACTOR TO FIELD VERIFY STRUCTURAL INTEGRITY OF EXISTING STRUCTURE WITH NEW PIPE CONNECTION AND REPLACE AS NECESSARY. 52' OF 6" COMBINED DOMESTIC AND FIRE PROTECTION SERVICE ELECTRICAL OUTLET. SEE ELECTRICAL PLANS FOR ROUTING AND DETAILS STORM PIPE D 53' OF 12"HDPE @ 1.0% STORM IE = 796.20 STORM IE = 796.45 STORM IE = 796.7269' OF 10" ROOF DRAIN LEAD @ 1.0% MIN 94' OF 10" ROOF DRAIN LEAD @ 1.0% MIN 95' OF 10" ROOF DRAIN LEAD @ 1.0% MIN 6' OF 6" ROOF DRAIN LEAD @ 1.0% MIN 6' OF 6" ROOF DRAIN LEAD @ 1.0% MIN GAS METER REMOVE EXISTING CURB INLET FRAME AND GRATE. REPLACE WITH NEW NEENAH FOUNDRY R-3067 FRAME AND GRATE TYPE C. MATCH EXISTING RIM ELEVATION PROTECT EXISTING ROUND INLET STRUCTURE. REMOVE EXISTING INLET FRAME AND GRATE. REPLACE WITH NEW NEENAH FOUNDRY R-1792-HG FRAME AND GRATE. MATCH EXISTING RIM ELEVATION PROTECT EXISTING ROUND INLET STRUCTURE. REMOVE EXISTING INLET FRAME AND GRATE. REPLACE WITH NEW NEENAH FOUNDRY R-1792-HG FRAME AND GRATE. MATCH EXISTING RIM ELEVATION PROTECT EXISTING ROUND INLET STRUCTURE. REMOVE EXISTING INLET FRAME AND GRATE. REPLACE WITH NEW NEENAH FOUNDRY R-3067 TYPE C CURB INLET FRAME AND GRATE. MATCH EXISTING RIM ELEVATION CATCH BASIN 1 (NEW STRUCTURE) [5'] NEENAH FOUNDRY R1792-GG RIM = 805.25 IE E = 797.93 IE W = 797.93 IE NE= 799.15 CURB INLET 1 (NEW STRUCTURE) NEENAH FOUNDRY R-3067 TYPE C RIM = 805.65 IE SE = 799.50 STORM PIPE A 24' OF 12"HDPE @ 1.0% (100 YR=880 GPM) CURB INLET 2 (NEW STRUCTURE) NEENAH FOUNDRY R-3067 TYPE C RIM = 805.72 IE SE = 796.53 CATCH BASIN 3 15" NYLOPLAST DRAIN BASIN W/ BLACK/SQUARE DECORATIVE GRATE. RIM = 807.50 IE S = 804.73 CATCH BASIN 2 15" NYLOPLAST DRAIN BASIN W/ BLACK/SQUARE DECORATIVE GRATE. RIM = 807.38 IE N =804.13 IE S =804.03 (NEW 12") STORM PIPE C 82' OF 12" HDPE @ 1.0% STORM PIPE B 60' OF 12"HDPE @ 1.0% 29' OF 6" ROOF DRAIN LEAD @ 1.0% MIN 193' OF 6" ROOF DRAIN LEAD @ 1.0% MIN S 6" = 797.53 39' OF 6" SAN PVC @ 1% MIN ELECTRICAL OUTLET. SEE ELECTRICAL PLANS FOR ROUTING AND DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS 808 SAN IE = 795.53 VALVE 31' OF 6" ROOF DRAIN LEAD @ 1.0% MIN31' OF 6" ROOF DRAIN LEAD @ 1.0% MIN 31' OF 6" DOWNSPOUT LEAD @ 1.0% MIN LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS ELECTRICAL OUTLET. SEE ELECTRICAL PLANS FOR ROUTING AND DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS LIGHTPOLE. SEE ELECTRICAL PLANS FOR DETAILS 806 806 806 806 807 805 804 803 807 808 IE NW 12" = 796.00 LOCATION OF APPARENT EXISTING STORM PIPE DEFORMITY OR DAMAGE PER STORM TELEVISING. CONTRACTOR TO UNCOVER/INSPECT EXISTING STORM SEWER AND MAKE NECESSARY REPAIRS TO PIPE JOINT OR CONNECTION AS NECESSARY. IF REQUIRED, PROVIDE NEW PIPE SEGMENT & JOINTS. LOCATION OF APPARENT EXISTING STORM PIPE DEFORMITY OR DAMAGE PER STORM TELEVISING. CONTRACTOR TO UNCOVER/INSPECT EXISTING STORM SEWER AND MAKE NECESSARY REPAIRS TO PIPE JOINT OR CONNECTION AS NECESSARY. IF REQUIRED, PROVIDE NEW PIPE SEGMENT & JOINTS. LOCATION OF APPARENT EXISTING STORM PIPE DEFORMITY OR DAMAGE PER STORM TELEVISING. CONTRACTOR TO UNCOVER/INSPECT EXISTING STORM SEWER AND MAKE NECESSARY REPAIRS TO PIPE JOINT OR CONNECTION AS NECESSARY. IF REQUIRED, PROVIDE NEW PIPE SEGMENT & JOINTS. LOCATION OF APPARENT EXISTING STORM PIPE DEFORMITY OR DAMAGE PER STORM TELEVISING. CONTRACTOR TO UNCOVER/INSPECT EXISTING STORM SEWER AND MAKE NECESSARY REPAIRS TO PIPE JOINT OR CONNECTION AS NECESSARY. IF REQUIRED, PROVIDE NEW PIPE SEGMENT & JOINTS. FLUSH/CLEAN EXISTING STORM PIPE SEGMENT TO REMOVE SEDIMENT & GRAVEL DEPOSITS. FLUSH/CLEAN EXISTING STORM PIPE SEGMENT TO REMOVE SEDIMENT & GRAVEL DEPOSITS. FLUSH/CLEAN EXISTING STORM PIPE SEGMENT TO REMOVE SEDIMENT & GRAVEL DEPOSITS. FLUSH/CLEAN EXISTING STORM PIPE SEGMENT TO REMOVE SEDIMENT & GRAVEL DEPOSITS. 806 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C1.3 CIVIL UTILITY PLAN IFA OCT. 1, 2026 30' 0 30' 60' SCALE: 1"= 30' NORTH Page 29 of 36 PROPOSED VESTIBULE FOOTPRINT: 153 SF ARCH FF = 100.00 CIVIL FF = 808.10 PROPOSED ADDITION FOOTPRINT: 2139 SF ARCH FF = 100.00 CIVIL FF = 808.10 STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. STAKEOUT INFORMATION:VERIFY STATION FOR INLETLOCATION. REFER TO STAKEOUT POLICYFOR STAKEOUT LOCATION AND OFFSETS. 808808 805 806 807 806 807 807 807 806 806 807 807 807 807 806 806 806 806 806 807 807 808 808 808809 808 808 808 808 808 806 806 806 806 807 805 804 803 807 808 806 1 2 3 45 67 8 (1) HONEYLOCUST TREE TO BE REMOVED (FAIR CONDITION) (4) HONEYLOCUST TREES TO BE REMOVED (POOR CONDITION) (7) HONEYLOCUST TREES TO BE REMOVED (POOR CONDITION) (11) HONEYLOCUST TREES TO BE REMOVED (POOR CONDITION) ALUMINUM EDGING ALUMINUM EDGING ALUMINUM EDGING TRIM TREES TRIM TREES REMOVE AND REPLACE EXISTING TREE (POOR CONDITION) TRIM TREES REMOVE (2) EVERGREEN TREES REMOVE STUMP ALUMINUM EDGING ARTIFICIAL TURF ARTIFICIAL TURF SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 30' 0 30' 60' SCALE: 1"= 30' NORTH SHEET DATES ISSUED FOR APPROVAL C1.4 CIVIL LANDSCAPE AND RESTORATION PLAN IFA OCT. 1, 2026 GENERAL NOTES: · SEE SHEET C0.2 FOR LANDSCAPE SPECIFICATIONS. · ALL BARE DISTURBED SOIL OUTSIDE OF MULCH AREAS TO BE SEEDED. HATCH KEY: HATCH LANDSCAPE MATERIAL NATURAL COLORED DECORATIVE STONE SEEDED LAWN BOULDERS 2-3' DIA. (QUANTITY - 43) BOULDERS 1-1.5' DIA. (QUANTITY -152) PLANTS PROVIDED LANDSCAPING CALCULATIONS ZONE PARKING LOT REQ. PLANTS - 10% OF DRIVES AND PARKING AREAS TO BE LANDSCAPED 110,966 SF x .1 = 11,096.6 SF OF LANDSCAPED AREA 16,991 SF OF LANDSCAPE AREA REMOVALS - SHOW EXACT TREES THAT ARE PROPOSED TO BE REMOVED 23 HONEYLOCUST TREES TREE 1 ORNAMENTAL TREE 2 EVERGREEN TREES CANOPY TREES SYMBOL COMMON NAME BOTANICAL NAME PLANT SCHEDULE QUANTITY PLANTED SIZE ROOT 9 CONT.18" HT.Invincibelle Limetta Hydrangea Hydrangea arborescens 'NCHA8' 7 B&B2 1/2" CAL.Hackberry Celtis occidentalis 1 B&B6' HT.River Birch Betula nigra 6 18" HT. CONT.Blue Rug Juniper Juniperus horizontalis 'Wiltonii' 9 CONT.18" HT.Invicibelle Ruby Hydrangea Hydrangea arborescens 'NCHA3' 17 16 1 GAL. 1 GAL. CONT. CONT. Gold Dew Tufted Hair Grass Karl Foerster Feather Reed Grass Deschampsia cespitosa 'Goldtau' Calamagrostis acutiflora 'Karl Foerster' 5 5 1 GAL. 1 GAL. CONT. CONT. Rosy Returns Daylily Happy Returns Daylily Hemerocallis 'Rosy Returns' Hemerocallis 'Happy Returns' 21 1 GAL. CONT.Grape Exceptions Coral Bells Heuchera 'Grape Exceptions' 8 B&B2 1/2" CAL.Espresso Kentucky Coffeetree Gymnocladus Dioicus 'Espresso-JFS' 6 1 1/2" CAL. B&BCumulus Allegheny Serviceberry Amelanchier laevis 'Cumulus' ORNAMENTAL TREES DECIDUOUS SHRUBS EVERGREEN SHRUBS ORNAMENTAL GRASSES PERENNIALS 9 B&B2 1/2" CAL.Sweet Street Linden Tilia americana 'Kromm' 12 1 GAL. CONT.Golden Japanese Forest Grass Hakonechloa macra 'Aureola' 27 1 GAL. CONT.Blue Oat Grass Helictotrichon sempervirens 8 1 GAL. CONT.Little Bluestem Schizachyrium scoparium 21 1 GAL. CONT.Mahogany Coral Bells Heuchera 'Mahogany' 18 1 GAL. CONT.Dolce Apple Twist Coral Bells Heuchera 'Apple Twist' 6 1 GAL. CONT.Montrose White Calamint Calamintha Nepeta 'Montrose White' 10 1 GAL. CONT.Cat's Pajama's Catmint Nepeta 'Cat's Pajamas' 7 1 1/2" CAL. B&BWinter King Hawthorn Crataegus viridis 'Winter King' 1 3 ZONE NUMBER TYPE LOCATION COVERAGE AREA IRRIGATION SYSTEM SCHEDULE 2 4 5 6 7 DRIP DRIP DETENTION POND AREA NORTHWEST FRONTAGE NORTHERN BUFFER SOUTHERN BUFFER SOUTHWEST PARKING ISLAND SOUTH PARKING ISLAND SOUTHEAST PARKING ISLAND 154 SF 154 SF 154 SF 424 SF 620 SF 1,269 SF 901 SF DRIP DRIP/ROTARY DRIP DRIP DRIP/ROTARY 8 NORTHEAST PARKING ISLAND 450 SFDRIP/ROTARY 3" MULCH WITH LANDSCAPE FABRIC WHEN IN PLANT BED VARIES VARIES DECIDUOUS TREE PLANTING DETAIL NOT TO SCALE SITUATE EXPOSED ROOT FLARE 2-3" ONLY WRAP TREE IF PLANTED NEAR DIG HOLE 2-3 TIMES WIDER THAN DIAMETER OF ROOT BALL BACKFILL USING CLEAN EXISTING SOIL REMOVED FROM HOLE AND SUPPLEMENT ABOVE FINISHED GRADE WITH CLEAN NATIVE SOIL AS NECESSARY EXISTING SUBGRADE ELIMINATE VOIDS, LIGHTLY TAMP, AND WATER WELL (SEE SPECIFICATIONS) BREAK UP SUBGRADE AND EXPOSED SIDES OF HOLE USING HAND TOOLS END OF GROWING SEASON (REMOVE IN SPRING) NOTE: ONLY USE TREE STAKING IF UNABLE TO STABILIZE TREE PROPERLY DURING BACKFILLING PRUNE BROKEN BRANCHES AFTER INSTALLATION AS NECESSARY REMOVE TOP 1/3 OF BURLAP, TWINE, AND WIRE CAGE FROM ROOT BALL EXISTING SUBGRADE VARIES NOT TO SCALE DECIDUOUS SHRUB PLANTING DETAIL NOTE: FOR MASS PLANTINGS EXCAVATE ENTIRE BED & BACKFILL W/ PREPARED SOIL. ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL FINISHED GRADE 2-3 TIMES DIMENSION OF ROOT BALL 3" MULCH - NO MORE THAN 1" ON TOP OF ROOT BALL PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN HOLE HAS BEEN BACKFILLED, DEEPLY WATER AROUND ROOT BALL TO SETTLE SOIL LOOSEN SOIL. DIG AND TURN SOIL TO REDUCE COMPACTION TO THE AREA AND DEPTH SHOWN PLANT AT FINISHED GRADE. DO NOT BURY BOTTOM BRANCHES. PRUNE OUT DEAD AND BROKEN BRANCHES EXISTING SUBGRADE VARIES NOT TO SCALE EVERGREEN SHRUB PLANTING DETAIL NOTE: FOR MASS PLANTINGS EXCAVATE ENTIRE BED & BACKFILL W/ PREPARED SOIL. ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL FINISHED GRADE 2-3 TIMES DIMENSION OF ROOT BALL 3" MULCH - NO MORE THAN 1" ON TOP OF ROOT BALL PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN HOLE HAS BEEN BACKFILLED, DEEPLY WATER AROUND ROOT BALL TO SETTLE SOIL LOOSEN SOIL. DIG AND TURN SOIL TO REDUCE COMPACTION TO THE AREA AND DEPTH SHOWN PLANT AT FINISHED GRADE. DO NOT BURY BOTTOM BRANCHES. PRUNE OUT ANY BROWN BRANCHES NOT TO SCALE PERENNIAL SPACING DETAIL ON CENTER SPACING VARIES. PERENNIALS TYPICALLY 1.5-3' WIDE AT MATURE SIZE. SEE PLAN AND PLANT SCHEDULE FOR FINAL LOCATIONS AND INSTALLED SIZE. PLANTS SHOWN AT MATURE SIZE ON PLANS NOT TO SCALE PARKING ISLAND PLANT BED DETAIL KEEP PLANTS 18-24" FROM CURBKEEP PLANTS 18-24" FROM CURB CURB AND GUTTER EXISTING SUBGRADE PAVEMENT SUBBASE TOPSOIL. SLIGHTLY MOUND IN THE CENTER OF THE ISLAND. MAINTAIN 6-12" TOPSOIL DEPTH THROUGHOUT PLANT BED AREA WIDTH VARIES - SEE PLANS 3" MULCH AREA. MAINTAIN 3" DEPTH THROUGHOUT ISLAND. MULCH ALONG CURB TO BE 2-3" BELOW TOP OF CURB TO REDUCE MULCH SPILLAGE IF TREES ARE PROPOSED WITHIN ISLANDS, THEY SHALL BE SET EVENLY BETWEEN BOTH CURBS. SEE PLAN FOR LOCATIONS LANDSCAPE FABRIC TO BE USED BELOW MULCH AREA LANDSCAPE FABRIC TO BE USED BELOW MULCH AREA NOT TO SCALE PLANT BED BETWEEN PAVEMENT DETAIL MULCH SHOULD BE 1-2" BELOW FINISHED GRADE OF PAVEMENT TO REDUCE CHANCE OF MULCH ESCAPING PLANT BED PAVEMENT (TYP.) EXISTING SUBGRADE PAVEMENT SUBBASE TOPSOIL. SEE SHRUB DETAIL FOR INSTALLATION INFO. 3" KEEP PLANTS AT LEAST 6" AWAY FROM EDGE OF PAVEMENT WIDTH VARIES - SEE PLANS LANDSCAPE FABRIC TO BE USED BELOW MULCH AREA NOT TO SCALE PLANT BED ALONG LAWN DETAIL LAWN MULCH AREA PER PLAN ALUMINUM EDGING TO BE USED IN AREAS WHERE MULCH MEETS LAWN PER PLAN. REFER TO LANDSCAPE SPECIFICATIONS FOR FURTHER INFORMATION ON EDGING.3" EDGING STAKES PER SUPPLIER SPECS. SUBGRADE LANDSCAPE FABRIC TO BE USED BELOW MULCH AREA WIDTH VARIES - SEE PLANS NOT TO SCALE ARTIFICIAL TURF DETAIL ORGANIC INFILL PER SUPPLIER SPECS ARTIFICIAL GRASS BLADES BACKING PER SUPPLIER SPECS 2 - 4" OF COMPACTED AGGREGATE BASE (USE SAME DEPTH THROUGHOUT TURF AREA - MATCH SUPPLIER SPEC) GEOTEXTILE NATURAL COMPACTED SUBGRADE CONCRETE 2 X 4 TREATED LUMBER NAILER BOARD MOUNTED 1/2" BELOW CONCRETE SURFACE AND SECURED WITH CONCRETE FASTNERS EVERY 2' 90% COMPACTION STAPLE OR NAIL TURF COMPOSITE WOOD BORDER AT PERIMETER AND SEAMS NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SUPPLIER SPECIFICATIONS IRRIGATION KEY: ZONE NUMBER ZONE AREA AND IRRIGATION LINE # 4 1 1/2" CAL. B&BArmstrong Maple Acer x freemanii 'Armstrong' Page 30 of 36 SHEET NUMBER PROJECT INFORMATION PROFESSIONAL SEAL JOB NUMBER 250405600 PROPOSED OFFICE FOR: CARBLISS CORPORATE OFFICE 2615 EASTERN AVENUE ● PLYMOUTH WI 53073 SHEET DATES ISSUED FOR APPROVAL C2.0 CIVIL DETAILS IFA OCT. 1, 2026 NOT TO SCALE FLUSH WALK DETAIL NOTE: SLOPE SLAB AWAY FROM BUILDING AT 1.5% MAX. NOT TO SCALE RAISED WALK DETAIL NOTE: SLOPE SLAB AWAY FROM BUILDING AT 1.5% MAX. 1.5% SLOPE MAX. 1.5% SLOPE MAX. 2' SEE PLAN 6" MIN 6" 1'-6" 6" MIN 6" MIN 0.10' 1'-6" DETECTABLE WARNING SURFACE. SURFACE TO BE TRUNCATED DOMES WITH A BASE DIAMETER OF 0.9" MIN. TO 1.4" MAX. AND A TOP DIAMETER OF OF 50% MIN. TO 65% MAX. OF THE BASE DIAMETER. HEIGHT OF DOMES SHALL HAVE A HEIGHT OF 0.2". TRUNCATED DOMES SHALL HAVE A CENTER-TO-CENTER SPACING OF 1.6" MIN. AND 2.4" MAX. AND A BASE-TO-BASE SPACING OF 0.65" MIN. MEASURED BETWEEN THE MOST ADJACENT DOMES ON THE GRID. DOMES SHALL BE ALIGNED IN A SQUARE GRID PATTERN.BWXXX.XX TWXXX.XX WHEEL STOP PAVEMENT 4" CONC. WALK BUILDING FELT (IF APPLICABLE) AGGREGATE BASE DETECTABLE WARNING PLATE (IF APPLICABLE). SEE C1.1 FOR PROPOSED LOCATIONS AGGREGATE BASE BUILDING FELT (IF APPLICABLE) 4" CONC. WALK PAVEMENT #4's T&B #4's T&B 18" CONCRETE CURB & GUTTER DETAIL NOT TO SCALE INVERTED SHEDDING NOTE #1 CRUSHED AGGREGATE BASE COURSE NOTE: 1. USE 4% GUTTER CROSS SLOPE UNLESS OTHERWISE NOTED IN THE PLANS. 2. THE BOTTOM OF CURB AND GUTTER MAY BE CONSTRUCTED EITHER LEVEL OR PARALLEL TO THE SLOPE OF THE SUBGRADE OR BASE AGGREGATE PROVIDED A 6" MIN. GUTTER THICKNESS IS MAINTAINED. 3. SEE SITE PLAN & GRADING PLAN FOR INVERTED & SHEDDING CURB LOCATIONS 12" 18" 6" 12" 12" 6"6" MIN 6" MIN SEE NOTE #2 XXX.XX FL POURED IN PLACE CONCRETE 1/4" R 3/4" R MAX. TCXXX.XX 2" R CURB TAPER DETAIL NOT TO SCALE 1'-6" CONSTRUCTION JOINT (TYP) SEE SITE PLAN FOR CONTINUATION RESERVED PARKING THIS SPACE VEHICLES WITH VET OR DIS PLATES OR STATE DISABLED CARD HANDICAP SIGNAGE WITH CONCRETE BASE DETAIL NOT TO SCALE ACCESSIBLE VAN GALVANIZED ROUND CAP PAINTED BLACK ADD VAN SIGN AT VAN ACCESSIBLE SPACES 2 3/8" DIA. STEEL PIPE-PAINTED BLACK FINISH GRADE POST SET IN CONCRETE EQ. EQ. NOT TO SCALE 6" PIPE BOLLARD DETAIL 8' 3'-0" (TYPICAL) 1-1/2" 3'-0" (TYPICAL) ALTERNATE: IDEAL SHIELD BOLLARD COVER OWNER TO VERIFY COLOR CONCRETE CAP (SMOOTH FINISH) 66"x6" DIA. CONCRETE FILLED STEEL PIPE (PAINTED) W/ 30" EXPOSURE. COLOR BY OWNER EXPAN. JOINT 1" MIN. BOND BREAKER 6" AGGREGATE BASE 18"Ø CONCRETE ENCASEMENT ASPHALT OR LANDSCAPE- SEE SITE PLAN INLET PROTECTION DETAIL NOT TO SCALE SEDIMENT LOG(SILT SOCK) INSTALLATION 4 ft max 4 ft max Note: Install fiber roll along a level contour. Fiber rolls 4 ft max 4 ft max Install a fiber roll near slope where it transitions into a steeper slope Fiber roll 20 inch Slope varies 4 ft long wood stakes- maximum 2 ft spacing TYPICAL FIBER ROLL INSTALLATION N.T.S. 4 inch bury Wood stake to penetrate netting, not Curlex material 16 inch minimum Vertical spacing along slope varies between 8 and 20 feet, or for every 2 (two) vertical feet of drop in elevation of slope. NOT TO SCALE TRACKPAD DETAILS 3" TO 6" STONE EXISTING PAVED STREET TRACKING PAD TRACKING PAD SHALL BE FULL WIDTH OF THE EGRESS POINT MIN. MIN. A A 12" MINIMUM THICKNESS MIN. INSTALL IN ACCORDANCE WITH WI DNR TECHNICAL STANDARD 1057 (CURRENT EDITION) GEO-TEXTILE FABRIC LINER AS NEEDED EXISTING STABILIZED SURFACE NOTE: TRACKING MATS SHALL BE INSPECTED DAILY. DEFICIENT AREAS SHALL BE REPAIRED OR REPLACED IMMEDIATELY NOT TO SCALE CONCRETE WASHOUT DETAIL 8' MINIMUM 8' MIN. B B 10 mil PLASTIC LINING WOOD FRAME SECURELY FASTENED AROUND ENTIRE PERIMETER WITH TWO STAKES TWO-STACKED 2X12 ROUGH WOOD FRAME STAKE (TYP) TYPE "ABOVE GROUND" WITH WOOD PLANKS 10 mil PLASTIC LINING SECTION B-B NOT TO SCALE PLAN NOT TO SCALE CONCRETE WASHOUT CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) PLYWOOD 48"X24" PAINTED WHITE BLACK LETTERS 6" HEIGHT LAG SCREWS 36" 36" WOOD POST 3.5"X3.5"X8' 2' MIN. 24" CONCRETE CURB & GUTTER DETAIL NOT TO SCALE INVERTED SHEDDING NOTE #1 CRUSHED AGGREGATE BASE COURSE NOTE: 1. USE 4% GUTTER CROSS SLOPE UNLESS OTHERWISE NOTED IN THE PLANS. 2. THE BOTTOM OF CURB AND GUTTER MAY BE CONSTRUCTED EITHER LEVEL OR PARALLEL TO THE SLOPE OF THE SUBGRADE OR BASE AGGREGATE PROVIDED A 6" MIN. GUTTER THICKNESS IS MAINTAINED. 3. SEE SITE PLAN & GRADING PLAN FOR INVERTED & SHEDDING CURB LOCATIONS 12" 24" 6" 18" 12" 6"6" MIN 6" MIN SEE NOTE #2 XXX.XX FL 3/4" R MAX. POURED IN PLACE CONCRETE 1/4" R TCXXX.XX 2" R NOT TO SCALE STORM CURB INLET DETAIL FLOW LINE SEE PLAN NOTE: CONCRETE AND STEELREINFORCEMENT SHALL CONFORM TOASTM C-478 REQUIREMENTS. NOTE: FINAL STRUCTURE SIZES TO BE VERIFIED WITH THE SUPPLIER 6" 12" MIN. NEENAH FOUNDRY OR EQ. R-3067 CAST IRON FRAME & GRATE AGGREGATE BASE PER PAVEMENT SECTION 4" PERFORATED UNDERDRAIN (SEE UTILITY PLAN FOR LOCATIONS AND INVERTS) 6" No. 1 STONE UNDISTURBED EARTH ADJUST TO GRADE WITH PRECAST CONCRETE EXTENSION RINGS, APPLY MORTAR IN JOINTS PRECAST CONC. M.H. SEGMENTS. SEAL ALL JOINTS WATERTIGHT PROVIDE COPOLYMER PROPYLENE PLASTIC STEPS M.A. IND. INC. MODEL PS-2-PF-S (ASTM C-478) OR EQUAL AT A MAXIMUM OF 16" O.C. IN ALL STORM STRUCTURES 5' OR GREATER IN DEPTH. NOT TO SCALE 26-1/2" DIA. INVERT ELEVATION SEE PLAN STORM CATCH BASIN DETAIL NOTE: CONCRETE AND STEEL REINFORCEMENT SHALL CONFORM TO ASTM C-478 REQUIREMENTS. NOTE: FINAL STRUCTURE SIZES TO BE VERIFIED WITH THE SUPPLIER VARIES 12" MIN. STANDARD FLAT TOP SLAB SECTION (HEIGHT TO BE DETERMINED BY SUPPLIER) WITH 27" OFFSET ACCESS HOLE PRECAST CONC. M.H. SEGMENTS. SEAL ALL JOINTS WATERTIGHT 4" PERFORATED UNDERDRAIN (SEE UTILITY PLAN FOR LOCATIONS AND INVERTS) 6" No. 1 STONE UNDISTURBED EARTH NEENAH FOUNDRY OR EQ. LOW PROFILE R-1792-GG ADJUST TO GRADE WITH PRECAST CONCRETE EXTENSION RINGS, APPLY MORTAR IN JOINTS WATERTIGHT JOINT PER ASTM C-443 PROVIDE COPOLYMER PROPYLENE PLASTIC STEPS M.A. IND. INC. MODEL PS-2-PF-S (ASTM C-478) OR EQUAL AT A MAXIMUM OF 16" O.C. IN ALL STORM STRUCTURES 5' OR GREATER IN DEPTH. MONOLITHIC PRECAST CONCRETE BASE SECTION NOT TO SCALE 12 MAX. 1 SECTION PLAN PAVEMENT 1:12 MAX. CURB RAMP DETAIL PLAN NOTE: ADA CURB RAMP SHALL CONFORM TO THE CURRENT EDITION OF ADA STANDARDS FOR ACCESSIBLE DESIGN FOR ALL REQUIREMENTS. 6'-0" STOOP/SIDEWALK 6" MAX 1'-6"6'-0" SEE PLAN (5'-0" MIN) 6'-0" #4's T&B DETECTABLE WARNING PLATE PAVEMENT 5" CONC. RAMP R/F W/ #4's T&B 4" AGGREGATE BASE DETECTABLE WARNING SURFACE. SURFACE TO BE TRUNCATED DOMES WITH A BASE DIAMETER OF 0.9" MIN. TO 1.4" MAX. AND A TOP DIAMETER OF OF 50% MIN. TO 65% MAX. OF THE BASE DIAMETER. HEIGHT OF DOMES SHALL HAVE A HEIGHT OF 0.2". TRUNCATED DOMES SHALL HAVE A CENTER-TO-CENTER SPACING OF 1.6" MIN. AND 2.4" MAX. AND A BASE-TO-BASE SPACING OF 0.65" MIN. MEASURED BETWEEN THE MOST ADJACENT DOMES ON THE GRID. DOMES SHALL BE ALIGNED IN A SQUARE GRID PATTERN. ADA SLOPE MAX. 1'-8"R. 2'-0"R. CENTER OF PARKING SPACE 16"3" 8" 8" 1'-0" 2'-0" 1'-0" 4" NOT TO SCALE HANDICAP STALL SYMBOL 6" RADIUS PAINT TO MATCH SHOPPING CENTER STANDARD OR AS REQUIRED CONFORM DIMENSIONS, CONFIGURATION, AND COLORS WITH LOCAL GOVERNMENTAL AGENCY AND ADA GUIDELINES NOT TO SCALE 6" VERTICAL CURB DETAIL 1'-6" 6" 6" PROVIDE (2) #4 BARS T & B PAVEMENT AGGREGATE BASE UNDISTURBED SOIL OR COMPACTED FILL TO A MIN. 95% COMPACTION CONCRETE FLUME DETAIL (PAVEMENT) NOT TO SCALE 24" 24" 6" CONCRETE FLUME 2" IN DEPTH UNDISTURBED SOIL OR COMPACTED FILL TO A MIN. 95% COMPACTION COMPACTED AGG BASE PER PAVEMENT SECTION Page 31 of 36 1.2 1.3 1.4 1.4 1.3 1.0 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 1.1 1.3 1.4 1.3 1.1 1.0 0.7 0.6 0.6 0.9 1.0 1.2 1.3 1.2 1.0 0.8 0.8 1.0 1.0 1.0 1.2 1.4 4.6 5.7 4.3 5.4 1.1 1.1 1.2 1.5 3.1 7.6 5.6 1.1 0.8 0.6 2.2 1.0 0.9 1.0 1.2 2.3 2.6 1.4 0.6 1.2 1 .2 1.1 1.1 1.0 1.1 1.3 1.2 1.3 2.1 2.7 2.4 2.0 1.2 1.8 4.9 5.0 1.7 1.4 5.6 8.3 9.6 9.1 2.5 6.0 9.3 7.5 4.8 3.3 2.2 4.1 3.9 4.6 7.4 7.0 5.4 7.8 4.0 4.4 5.6 4.8 5.0 5.9 5.5 4.6 0.3 0 .3 0.3 0.8 11.1 7.7 7 .6 5.4 9.8 9.1 9.8 8.1 4.5 5.3 6.2 5.0 0.8 0.315.1 0.1 0 .1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.3 0.4 0.5 0.4 0.4 0.3 0.2 0.1 0.2 0.5 0.6 0.7 0.6 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.7 0.9 0.9 0.8 0.6 0.4 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.4 0.9 1.2 1.2 1.1 0.8 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.5 1.3 1.6 1.5 1.3 0.9 0.5 0.3 0.2 0.2 0.3 0.4 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.5 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.5 1.5 1.8 1.8 1.5 1.1 0.7 0.4 0.4 0.4 0.4 0.6 0.6 0.7 0.5 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.7 0.6 0.7 0.5 0.5 0.5 0.4 0.5 0.5 0.5 0.5 0.6 0.6 0.9 0.7 0.7 0.6 0.5 0.5 0.4 0.4 0.3 0.4 0.4 0.4 0.5 0.6 0.7 0.9 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.6 1.6 2.2 2.2 1.8 1.4 1.0 0.8 0.9 1.1 1.3 1.9 2.5 2.1 1.5 1.3 1.2 1.1 1.2 1.3 1.4 1.4 2.0 2.3 2.1 1.4 1.4 1.3 1.2 1.1 1.1 1.2 1.3 1.5 1.8 2.5 2.6 2.1 1.5 1.3 1.1 0.9 0.8 0.7 1.2 1.5 1.8 2.5 2.6 2.1 1.5 1.3 1.0 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.4 0.9 2.1 1.6 2.1 2.1 2.0 1.8 1.7 1.6 1.7 1.8 1.0 0.6 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.5 0.7 2.2 0.7 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.9 0.8 0.6 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.7 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.6 1.3 1.5 1.5 1.5 1.5 1.4 1.3 1.2 0.9 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.6 1.1 0.8 1.0 1.3 1.6 1.0 0.9 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.5 7.6 5.0 4.4 1.2 1.6 1.1 0.9 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.4 9.9 9.4 8.0 1.3 1.8 1.3 1.1 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.3 4.5 4.8 4.6 1.4 2.0 1.5 1.2 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.3 1.6 2.3 1.8 1.4 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.3 1.7 2.5 2.1 1.5 1.0 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.2 1.8 2.6 2.2 1.5 1.0 0.7 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.2 1.8 2.7 2.1 1.5 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 1.8 2.5 1.9 1.5 1.1 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.3 1.8 2.4 1.7 1.4 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.3 1.7 2.3 1.5 1.3 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.2 1.7 2.2 1.5 1.3 1.1 0.9 0.7 0.5 0.3 0.2 0.1 0.1 0.1 0.2 1.6 2.2 1.4 1.3 1.1 0.9 0.7 0.5 0.3 0.2 0.1 0.1 0.2 1.6 2.2 1.5 1.3 1.1 0.9 0.7 0.5 0.3 0.2 0.1 0.1 0.2 1.6 2.2 1.5 1.3 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.2 1.6 2.3 1.7 1.4 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.2 1.6 2.3 1.9 1.5 1.1 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.2 1.7 2.3 2.1 1.5 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.2 1.6 2.3 2.2 1.5 1.0 0.7 0.5 0.3 0.2 0.1 0.1 0.1 0.2 1.5 2.1 2.1 1.5 1.0 0.7 0.5 0.3 0.2 0.1 0.1 0.1 0.2 1.4 1.8 1.8 1.4 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.2 1.3 1.6 1.5 1.2 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.3 1.2 1.4 1.2 1.1 0.9 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.3 1.1 1.2 1.1 0.9 0.8 0.6 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.2 1.1 1.0 1.0 0.9 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.2 0.8 1.0 0.9 0.8 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.2 0.9 1.0 0.9 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.2 0.9 0.9 1.0 0.8 0.6 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.8 0.8 0.9 0.7 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.3 0.7 0.7 0.8 1.0 0.6 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.8 1.4 1.0 1.3 1.1 0.9 0.8 0.8 0.9 1.0 1.2 1.4 1.7 2.4 2.6 2.1 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.9 5.7 0.5 0.6 0.8 0.9 1.1 1.8 1.8 1.5 1.0 0.9 0.7 0.5 0.5 0.4 0.4 0.4 0.4 0.5 0.6 0.6 0.8 0.7 0.7 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.9 10.0 6.9 0.2 0.2 0.3 0.3 0.5 0.6 0.5 0.6 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.9 6.5 0.2 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.3 1.1 6.4 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 1.1 6.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 1.1 1.1 0.9 0.1 0.2 0.9 0.2 0.9 0.2 0.8 0.2 0.6 0.1 0.4 0.8 1.2 1.4 2.2 3.2 3.4 2.3 2.2 2.3 3.3 3.2 2.1 1.4 1.1 1.3 1.9 3.4 3.4 0.1 0.2 0.4 0.7 0.9 1.5 1.6 1.7 1.7 1.5 1.7 1.7 1.6 1.5 1.0 0.9 0.9 1.3 1.6 1.6 0.1 0.2 0.3 0.4 0.4 0.5 0.5 0.7 0.7 0.6 0.5 0.5 0.5 0.5 0.4 0.4 0.5 0.4 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.7 0 .9 1.0 2.0 2.3 2.6 2.6 2.5 2.1 1.8 1.5 1.3 1.1 1.1 1.2 1.4 1.6 1.9 2.3 2.6 2.6 2.4 2.0 1.6 1.3 1.0 0.8 1.9 1.9 1.9 2.0 2.2 2.6 2.8 2.9 2.7 2.3 1.9 1.6 1.4 1.3 1.2 1.2 1.4 1.5 1.8 2.1 2.5 2.8 2.8 2.6 2.1 1.7 1.4 1.1 0.9 2.0 1.9 2.0 2.0 2.2 2.5 2.7 2.8 2.6 2.3 2.0 1.8 1.5 1.4 1.3 1.4 1.5 1.6 1.9 2.1 2.4 2.6 2.6 2.4 2.1 1.7 1.4 1.2 1.0 1.8 1.9 1.9 1.9 2.0 2.1 2.2 2.2 2.2 2.1 1.9 1.8 1.6 1.5 1.4 1.4 1.5 1.6 1.8 2.0 2.1 2.1 2.1 2.0 1.8 1.6 1.4 1.2 1.0 1.7 1.8 1.8 1.7 1.7 1.7 1.8 1.8 1.9 1.8 1.7 1.6 1.5 1.5 1.4 1.4 1.4 1.5 1.6 1.7 1.8 1.8 1.7 1.6 1.5 1.4 1.3 1.1 1.0 1.7 1.7 1.6 1.6 1.5 1.6 1.7 1.7 1.7 1.7 1.6 1.5 1.4 1.4 1.5 1.4 1.5 1.6 1.6 1.6 1.6 1.5 1.4 1.4 1.3 1.3 1.1 1.0 1.8 1.7 1.7 1.6 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.5 1.5 1.6 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.5 1.4 1.3 1.4 1.3 1.2 1.2 2.0 2.1 2.1 1.8 1.6 1.7 1.7 1.7 1.8 1.8 1.8 1.7 1.6 1.8 1.7 1.7 1.8 1.7 1.7 1.7 1.7 1.7 1.6 1.5 1.7 1.5 1.4 1.4 2.4 2.4 2.4 2.0 1.9 2.0 1.9 1.9 1.9 1.9 2.0 2.0 1.9 2.2 2.0 2.0 2.0 2.0 1.9 1.9 1.9 2.0 2.0 1.8 2.1 1.8 1.8 1.7 2.9 2.8 2.7 2.5 2.4 2.3 2.2 2.1 2.0 2.2 2.4 2.5 2.5 2.7 2.5 2.5 2.4 2.2 2.1 2.0 2.2 2.3 2.4 2.5 2.6 2.4 2.3 2.1 3.3 3.6 4.3 3.7 3.2 2.7 2.5 2.2 2.1 2.4 2.7 3.1 3.7 4.5 3.8 3.4 2.8 2.5 2.2 2.1 2.4 2.7 3.0 3.6 4.5 3.7 3.2 2.5 3.5 4.0 3.8 3.7 3.7 2.9 2.6 2.2 2.2 2.5 2.9 3.5 4.3 4.5 3.9 4.0 3.0 2.7 2.3 2.2 2.4 2.8 3.3 4.2 4.0 3.8 3.8 2.7 3.4 3.8 4.5 3.8 3.4 2.8 2.6 2.3 2.3 2.5 2.9 3.2 3.8 3.9 3.5 2.9 2.7 2.3 2.2 2.5 2.8 3.0 3.6 4.4 3.7 3.2 2.5 3.2 3.2 3.0 2.8 2.7 2.6 2.5 2.3 2.3 2.5 2.6 2.7 2.8 2.9 2.6 2.7 2.6 2.5 2.3 2.2 2.4 2.5 2.6 2.6 2.7 2.4 2.4 2.2 2.9 2.9 2.9 2.4 2.4 2.4 2.4 2.4 2.3 2.4 2.4 2.4 2.2 2.5 2.2 2.3 2.4 2.3 2.3 2.2 2.3 2.3 2.3 2.1 2.3 2.0 1.9 1.9 2.7 2.8 2.8 2.4 2.2 2.3 2.3 2.4 2.4 2.3 2.3 2.2 2.1 2.2 2.1 2.1 2.2 2.2 2.2 2.3 2.2 2.2 2.1 1.9 2.1 1.9 1.7 1.7 2.6 2.6 2.5 2.4 2.1 2.2 2.4 2.4 2.4 2.3 2.2 2.0 1.9 2.0 2.0 1.9 2.1 2.2 2.3 2.3 2.2 2.1 2.0 1.8 1.9 1.8 1.6 1.5 2.5 2.6 2.5 2.4 2.1 2.2 2.4 2.4 2.4 2.4 2.2 2.0 1.9 2.0 2.0 1.9 2.0 2.2 2.3 2.3 2.2 2.1 1.9 1.8 1.8 1.8 1.5 1.5 2.6 2.7 2.7 2.6 2.2 2.3 2.5 2.5 2.4 2.4 2.2 2.0 1.9 2.0 2.0 1.9 2.1 2.2 2.3 2.3 2.2 2.1 2.0 1.8 1.9 1.8 1.6 1.5 2.7 2.9 2.8 2.7 2.3 2.4 2.5 2.5 2.4 2.3 2.3 2.2 2.0 2.2 2.1 2.0 2.2 2.2 2.2 2.3 2.2 2.2 2.1 1.9 2.1 1.9 1.7 1.7 2.9 3.2 2.8 2.8 2.8 2.6 2.6 2.5 2.4 2.4 2.4 2.4 2.2 2.4 2.2 2.3 2.3 2.3 2.3 2.2 2.3 2.3 2.3 2.1 2.3 2.1 1.9 1.9 3.1 3.7 3.6 4.1 3.6 3.0 2.8 2.6 2.4 2.5 2.6 2.7 2.7 2.9 2.6 2.7 2.6 2.5 2.3 2.2 2.4 2.5 2.6 2.7 2.8 2.5 2.5 2.2 3.1 4.0 3.7 4.6 4.2 3.2 2.9 2.5 2.4 2.6 2.9 3.1 3.8 4.6 3.9 3.5 2.9 2.7 2.3 2.2 2.4 2.8 3.1 3.7 4.5 3.8 3.3 2.6 3.0 3.7 3.8 4.5 3.7 2.9 2.7 2.5 2.3 2.5 2.9 3.4 4.2 4.6 3.9 4.1 3.1 2.7 2.3 2.2 2.4 2.8 3.3 4.2 4.3 3.8 3.9 2.7 2.7 3.1 2.7 2.8 2.7 2.5 2.4 2.3 2.2 2.4 2.8 3.1 3.7 4.5 3.8 3.4 2.8 2.6 2.2 2.1 2.3 2.6 2.9 3.5 4.3 3.6 3.2 2.5 2.3 2.5 2.4 2.3 2.0 2.0 2.0 2.0 2.1 2.2 2.4 2.5 2.6 2.7 2.5 2.6 2.4 2.3 2.1 2.0 2.1 2.3 2.4 2.4 2.6 2.3 2.3 2.1 2.0 2.0 2.1 2.0 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.1 1.9 2.2 2.0 2.0 2.0 2.0 1.9 1.9 1.9 1.9 2.0 1.8 2.0 1.8 1.7 1.7 1.6 1.6 1.6 1.6 1.3 1.4 1.5 1.6 1.7 1.7 1.8 1.8 1.6 1.8 1.7 1.7 1.8 1.7 1.7 1.7 1.7 1.7 1.6 1.5 1.7 1.5 1.4 1.4 1.3 1.3 1.3 1.2 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.5 1.4 1.6 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.5 1.4 1.3 1.4 1.3 1.2 1.2 1.2 1.2 1.2 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.4 1.4 1.4 1.4 1.5 1.4 1.5 1.6 1.6 1.6 1.6 1.5 1.5 1.4 1.3 1.3 1.1 1.0 1.1 1.2 1.2 1.2 1.2 1.3 1.4 1.5 1.5 1.5 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.7 1.8 1.8 1.8 1.7 1.6 1.5 1.4 1.3 1.1 1.0 1.1 1.3 1.3 1.4 1.6 1.7 1.7 1.8 1.7 1.6 1.6 1.4 1.4 1.3 1.4 1.5 1.6 1.8 2.0 2.1 2.2 2.1 2.0 1.9 1.6 1.4 1.2 1.0 1.2 1.4 1.5 1.7 2.0 2.2 2.2 2.2 2.0 1.8 1.7 1.5 1.4 1.3 1.3 1.5 1.6 1.8 2.1 2.4 2.6 2.7 2.5 2.1 1.8 1.4 1.2 1.0 1.1 1.3 1.6 1.9 2.3 2.6 2.7 2.5 2.2 1.9 1.6 1.4 1.3 1.2 1.2 1.4 1.5 1.7 2.1 2.5 2.8 2.8 2.6 2.2 1.7 1.4 1.1 0.9 1.1 1.2 1.5 1.8 2.3 2.6 2.7 2.6 2.1 1.7 1.5 1.3 1.1 1.1 1.2 1.3 1.6 1.9 2.2 2.6 2.6 2.4 2.0 1.6 1.3 1.0 0.8 0.9 1.1 1.6 2.0 2.5 2.5 2.3 1.8 1.5 1.3 1.5 1.2 1.0 0.7 1.3 1 .2 1.3 1.6 1.9 2.4 2.5 2.5 2.2 2.0 1.8 1.8 1.9 2.0 2.1 2.1 2.4 2.4 2.4 1.7 1.4 1.3 1.4 1.7 2.2 2.6 2.8 2.7 2.5 2.2 2.0 2.0 2.0 2.1 2.2 2.5 2.6 2.5 2.6 2.5 2.2 2.1 1.9 2.2 1.7 1.4 1.3 1.4 1.7 2.1 2.4 2.6 2.6 2.4 2.2 2.0 1.9 2.0 2.0 2.0 2.1 2.3 2.3 2.3 2.1 2.0 2.0 1.9 2.0 1.6 1.3 1.3 1.4 1.6 1.8 2.0 2.1 2.1 2.0 1.9 1.8 1.7 1.7 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.7 1.8 1.8 1.4 1.1 1.0 1.1 1.2 1.0 1.2 1.3 1.5 1.6 1.2 0.9 0.9 1.5 1.3 1.0 0.9 0.9 0.9 1.7 2.1 1.9 1.8 1.6 1.2 2.0 2.5 3.4 2.2 1.6 2.2 2 .4 2.5 2.4 2.4 2.5 2.3 2.5 2.6 1.7 2.3 2.4 1.6 2.0 2.0 1.4 1.7 1.7 1.1 1.4 1.5 0.9 1.3 1.5 0.8 1.2 1.6 0.8 1.2 1.3 0.9 1.6 2.0 1.0 2.1 3.2 1.0 2.3 1.0 2.3 3.1 1.0 1.9 2.3 1.0 1.8 2.1 1.1 2.0 2.1 0.9 2.2 3.3 0.9 2.2 3.5 0.9 1.7 1.8 0.7 1.2 1.4 1.0 0.9 1.0 1.1 0.8 1.4 1.8 0.8 2.0 2.9 0.9 2.2 3.9 0.9 2.0 2.9 0.9 1.6 1.9 0.8 1.5 1.7 0.9 1.7 2.0 0.9 2.1 2.9 0.9 2.2 3.9 1.9 2.8 1.4 1.7 1.3 1.3 1.3 1.5 1.7 1.8 2.2 3.4 2.3 3.4 2.1 2.2 2.0 2.3 2.1 2.3 2.3 3.3 2.1 3.5 1.7 1.8 1.0 1.3 0.0 0 .0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.8 0.8 0.6 0.6 14.1 4 .7 3.5 4.1 L24-1 L24-2 L24-3 L24-4 L224-1 L224-2 L13H-1 L13H-2 RL1-1R L1-2RL1-4RL1-5RL1-6RL1-7RL1-8RL1-9RL1-10RL1-11RL1-12 RL1-18RL1-19RL1-20RL1-21RL1-22RL1-23 RL1-24RL1-25RL1-26RL1-27RL1-28RL1-29 RL1-30RL1-31RL1-32RL1-33RL1-34RL1-35 RL1-36 B1-1 B 1-2 B1-3 B1-4 B1-5 B1-6 B1-7 L12H-1 WP2-1 WP2-2WP2-3 WP2-4 WP2-5 WP2-7 WP2-8 WP2-9 WP2-10 WP2-11 L13H-3 L13H-4 CL11-1 CL11-2 CL11-4 CL11-5 CL11-7 CL11-8 L13H-5 PT1-1 L12H-2 C610-1 C610-2 C610-3 C610-4 C610-5 C610-6 C610-7 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 0.5 fc 14.1 fc 0.0 fc N/A N/A C alc Zone #2 2.7 fc 11.1 fc 0.3 fc 37.0:1 9.0:1 CUSTOMER PARKING 2.1 fc 4.7 fc 0.6 fc 7.8:1 3.5:1 EMPLOYEE ENTRANCE 4.2 fc 11.1 fc 0.8 fc 13.9:1 5.3:1 EMPLOYEE PARKING 1.8 fc 3.5 fc 0.8 fc 4.4:1 2.3:1 FRONT ENTRANCE CANOPY 6.8 fc 15.1 fc 0.3 fc 50.3:1 22.7:1 REAR DRIVE 1.8 fc 4.1 fc 0.6 fc 6.8:1 3.0:1 Schedule Symbol Label QTY Catalog Number Description Number Lamps Lumens per Lamp LLF Wattage L24 4 DSX1 LED P6 40K 80CRI T4M D-Series Size 1 Area Luminaire P6 Performance Package 4000K CCT 80 CRI Type 4 Medium 1 19126.33 0.9 330.5 L224 2 [...] [...] 1 [ . . . ] 0.9 330.5 L13H 5 DSX1 LED P6 40K 80CRI T3M HS D-Series Size 1 Area Luminaire P6 Performance Package 4000K CCT 80 CRI Type 3 Medium Houseside Shield 1 16335.1 0.9 165.2497 RL1 30 EX5-FCG Exton 5W-Cylinder Gem 1 246 0.9 5.29 B1 7 PBL-14L-350-NW-G2-5-UNV Pureform Gen2 - PBL Bollard 1 1758 0.9 17.7 L12H 2 DSX1 LED P6 40K 80CRI T2M HS D-Series Size 1 Area Luminaire P6 Performance Package 4000K CCT 80 CRI Type 2 Medium Houseside Shield 1 16164.02 0.9 165.2497 WP2 10 WDGE2 LED P4 50K 80CRI T3M WDGE2 LED WITH P4 - PERFORMANCE PACKAGE, 5000K, 80CRI, TYPE 3 MEDIUM OPTIC 1 4217.163 0.9 46.6589 CL11 6 I.LBIO5-940-WF-REM(SL54- S_I.07221) Laser Blade InOut recessed – small body 5X – IP65 – Neutral White LED – Remote power supply – Wide Flood optics 1 923.6442 0.9 9.79 PT1 1 PPT-P-A02-840-T5M PureForm LED area small precision PPT, 40 LED's, 4000K CCT, TYPE T5M OPTIC, 80CRI 1 3457 0.9 20.8 C610 7 LDN6 ALO1 @10LM SWW1 @40K AR LSS 6IN LDN Downlight 1000LM 4000K Clear Semi-Specular 1 1311 0.9 13.08 Page 32 of 36 Page 33 of 36 City of Plymouth CONDITIONAL USE PERMIT (2615 Eastern Avenue, LLC – Carbliss Signs) This Conditional Use Permit (the “Permit”) is granted by the City of Plymouth, a Wisconsin municipal corporation, maintaining its principal office at 128 Smith Street, Plymouth, WI 53073 through its Plan Commission, to 2615 Eastern Avenue, LLC (dba Carbliss) a limited liability company, maintaining its principal office at N5298 Kyle Court, Plymouth, WI 53073 (the “Owner”). The Permit is granted to the Owner for the property with tax key number 59271820985 located at 2615 Eastern Avenue within the City of Plymouth, Wisconsin, as further defined by the Condominium Plat/Declarations #2188697/2188698 and the amendments thereto (the “Property”), to grant relief from City Code Section 13-1-106(a) which limits total sign area to one square foot for each lineal foot of the building. The Owner seeks to construct signs with 55 square feet of Carbliss text, 51 square feet of Carbliss c ircle, 87 square feet of Pour House, 60 square feet entrance signa ge, and three (3) digital display signs, each with a dimension of 198 square feet for a total of 847 square feet of signage on the north side of the existing building on the Property (the “Signs”). The Owner seeks approval to install signage that exceeds the signage allowed under City Code Section 13-1-106(a) by 457 square feet. The Permit is granted with the following conditions: 1. Applicant. The Conditional Use Permit (CUP) is issued to 2615 Eastern Avenue, LLC (dba Carbliss). 2. Approved Use. The CUP is issued for the construction, maintenance, display and use of the Signs, as further described in the CUP application dated September 29, 2026, attached hereto and incorporated herein (the “CUP application”). The Owner shall otherwise comply with the City of Plymouth Zoning Code, Article H, Signs and Billboards. 3. Sign Content. The signs allowed under the CUP shall be limited to the content identified in the CUP application and the Permit. No off-premises commercial advertising is allowed under any circumstances. 4. Restrictions on Digital Display Signs. Digital signage may incorporate full-motion video, animation, and changing colors, which shall be subject to review by city staff six months after the signage has been installed and is operational to verify that the Page 34 of 36 digital signage has not been identified by law enforcement as a factor in any traffic related incidents. In the event the digital signage has been a factor in any traffic related incidents, the Plan Commission may revoke the allowance of the full-motion video, animation, and changing colors granted under the Permit. The digital signage shall not include strobe effects or repetitive flashing or blinking. The changing visual display shall be allowed between the hours of 7:00 a.m. and 11 p.m. During all other hours, the digital signs may be lit with a static display. 5. Approval Non-Transferable. The CUP is limited in duration to the Owner’s ownership and use of the Property and is non- transferable to subsequent owners or lessees of the Property. 6. City Staff Approval. The City of Plymouth City Administrator, Community Development Director, City Attorney, and Building Inspector, have reviewed the conditional use permit application for substantial compliance with the City of Plymouth Code of Ordinances. 7. Other Regulations. Nothing herein shall constitute a waiver or limitation of the Owner’s compliance with all other City of Plymouth ordinances and regulations, including all other requirements of the Zoning Code. 8. Enforcement. The conditions imposed herein (including the conditions imposed by any plans or changes submitted hereafter), shall all be enforced as on-going conditions of the Permit. Failure of the Owner to comply with these conditions shall entitle the City to take enforcement action, which may include forfeitures, injunctions, and/or termination of the Permit, which in turn will require the Owner to remove the signs exceeding the square footage otherwise allowed under Section 13-1-106(a). 9. Recording. A copy of this Permit, or a Memorandum of Permit, without attachments, may be recorded with the Sheboygan County Register of Deeds by either party. 10. Binding Affect: This Permit shall be binding upon both parties. Nothing herein shall be construed as limiting the right of the Owner to sell, give, or otherwise convey the Property. 11. Owner Approval. This Conditional Use shall not become effective and shall not be recorded until the Owner acknowledges his/her/its acceptance of the Permit by signing this document in the space provided below. The Owner warrants and Page 35 of 36 represents that the individual signing on behalf of 2615 Eastern Avenue, LLC, has full authority to bind the Owner. Introduced and adopted this ___day of __________, 20 _____. CITY OF PLYMOUTH PLAN COMMISSION Approved: ___________________________ Attest: __________________________ Donald Pohlman, Chairman Jack Johnston, Secretary OWNER APPROVAL The undersigned Owner hereby acknowledges receipt of this Conditional Use and hereby acknowledges that the development and use of the property shall conform with the terms and conditions of this Permit and the City of Plymouth Zoning Code. The undersigned further represents that he or she has full authority to execute this Conditional Use Permit on behalf of the Owner and to bind the Owner to the terms hereof. 2615 Eastern Avenue, LLC Signature_____________________________________ Dated: ____________________ Amanda Kroener, member Page 36 of 36

Source: City of Plymouth website. First collected Nov 7, 2026.