RecordWell Data

Plan-Commission-Meeting-Agenda-Packet-11-19-2026.pdf

City of Franklin · Milwaukee County · meeting of Nov 19, 2026 · Agenda packets

Open the original document More from City of Franklin

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

FRANKLIN CITY HALL CHAMBERS 9229 W. LOOMIS ROAD FRANKLIN, WISCONSIN PLAN COMMISSION MEETING AGENDA Thursday, November 19, 2026 at 6:00 P.M. A. Call to Order and Roll Call B. Approval of Minutes 1. Approval of the regular meeting of November 5, 2026. C. Public Hearing Business Matters. 1. City of Franklin, Natural Resource Special Exception (NRSE). Request to allow for work by the Metropolitan Milwaukee Sewerage District (MMSD) Reforestation and Wetland Restoration Program, in partnership with Ducks Unlimited. The proposed work will result in seven (7) acres of wetland restoration and plant 102 trees upon property located at 8120 S Lovers Lane Rd. (TKNs 801 9986 000, 801 9985 000, 801 9984 000, and 801 9987 000). D. Citizen comment period. Citizens may comment upon the Business Matter items set forth on this Meeting Agenda. E. Business Matters 1. SixSibs Capital, Site Plan . Request to allow for development of two 128,000 square foot industrial buildings with related truck and passenger parking, upon property located at 10651 S Hickory St. (TKN 950 9002 000). 2. Unified Development Ordinance Fee Schedule. Resolution to adopt a fee schedule for the Unified Development Ordinance (UDO) pursuant to UDO Section 15-9-01D Fees. F. Adjournment The YouTube channel “City of Franklin WI” will live stream the Plan Commission meeting so the public can watch and listen to it at https://www.youtube.com/c/CityofFranklinWIGov. Any questions on this agenda may be directed to the Department of City Development’s office at 414-425-4024, Monday through Friday, 8 AM – 4:30 PM. *Supporting documentation and details of these agenda items are available at City Hall during regular business hours. **Notice is given that a majority of the Common Council may attend this meeting to gather information about an agenda item over which they have decision-making responsibility. This may constitute a meeting of the Common Council per State ex rel. Badke v. Greendale Village Board, even though the Common Council will not take formal action at this meeting. [Note: Upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through appropriate aids and services. For additional information, contact the City Clerk’s office at 414- 425-7500.] REMINDERS: Next Regular Plan Commission Meeting: December 3, 2026. City of Franklin unapproved Plan Commission Meeting November 5, 2026 Minutes A. Call to Order and Roll Call Mayor John Nelson called the November 5, 2026, Plan Commission meeting to order at 6:00 p.m. in the Council Chambers at Franklin City Hall, 9229 West Loomis Road, Franklin, Wisconsin. Present were Mayor John Nelson, Alderman Nabil Salous , Alderwoman Michelle Eichmann and Commissioners Kevin Haley and Michael Shawgo . Excused were Patrick Leon and Rebecca Specht. Also present were City Attorney Christina Lucchesi, Director of Administration Kelly Hersh, Principal Planner Marion Ecks, and Associate Planner Luke Hamill. B. Approval of Minutes – Regular Meeting of September 3, 2026. Commissioner Haley moved and Commissioner Shawgo seconded a motion to approve the meeting minutes. On voice vote, all voted ‘aye’; motion carried (4-0-2). C. Public Hearing Business Matters 1. Burleson, Zoning Map Amendment and Certified Survey Map. Request to recommend approval of a Zoning Map Amendment (Rezoning) to rezone from R-SE Suburban/Estate Residence District to R-SR Suburban Residence District and a two-lot Certified Survey Map upon property located at 8748 S 83 rd Street (TKN 849 0100 000). Please note the public hearing is only for the Zoning Map Amendment portion of this request. Associate Planner Luke Hamill presented the Zoning Map Amendment and Certified Survey Map Request. The Official Notice of Public Hearing was read into the record by Associate Planner Luke Hamill and the Public Hearing opened at 6: 07 pm and closed at 6: 11 pm. The Public Hearing was reopened for further public comment at 6:11 pm and closed at 6:13 pm. Alderman Salous moved and Commissioner Haley seconded a motion to recommend approval of an ordinance to amend the Unified Development Ordinance (Zoning Map) to rezone the property bearing Tax Key Number 849 0100 000 from R-SE Suburban/Estate Residence District to R-SR Suburban Residence District. On roll call vote, all voted ‘aye’; motion carried (4-0-2). Alderwoman Eichmann moved and Alderman Salous seconded a motion to recommend approval of a resolution conditionally approving a two-lot Certified Survey Map, being a redivision of Lot 10, Block 10, in Security Acres Addition, being a Subdivision of the West ½ of the Northeast ¼ of Section 21, Town 5 North, Range 21 East in the City of Franklin, Milwaukee County, Wisconsin. (Tax Key No. 849 0100 000). On roll call vote, all voted ‘aye’; motion carried (4-0-2). D. Citizen comment period. Citizens may comment upon the Business Matter items set forth on this meeting agenda. The citizen comment period opened at 6:22 p.m. and closed at 6:22 p.m. E. Business Matters 1. Angel Taber, Certified Survey Map. Request for approval of a 2-Lot Certified Survey Map for property zoned R-SR - Suburban Residence District located at 7461 S 68TH ST (TKN 756 9999 000). Principal Planner Marion Ecks presented the Certified Survey Map request. Alderman Salous moved and Alderwoman Eichmann seconded a motion to recommend approval of a resolution approving a two -Lot Certified Survey to divide the property located at 7461 S 68th Street, being a part of the Southeast ¼ of the Northwest ¼ of Section 10, Township 5 North, Range 21 East, in the City of Franklin, Milwaukee County, Wisconsin. (Angel Taber, Applicant and Property Owner). On roll call vote, all voted ‘aye’; motion carried (4-0-2). F. Adjournment Alderwoman Eichmann moved and Commissioner Haley seconded to adjourn the meeting at 6:27 pm. On voice vote, all voted ‘aye’; motion carried (4-0-2). 1 CITY OF FRANKLIN REPORT TO THE PARKS COMMISSION Meeting of November 9, 2026 Natural Resource Special Exception RECOMMENDATION: City Development Staff recommends approval of the proposed Natural Resource Special Exception (NRSE), subject to the conditions of in the attached draft approval documents. Project Name: City of Franklin NRSE Property Owner: City of Franklin Applicant: City of Franklin Property Address/Tax Key Number: 8120 S LOVERS LANE RD / 801 9986 000 801 9985 000, 801 9984 000 & 801 9987 000 Aldermanic District: District 2 Agent: Tally Hamilton, Ducks Unlimited, Inc. Zoning District: P Park Use of Surrounding Properties: Residential, Institutional Application Request: NRSE Staff Planner: Marion Ecks, AICP The four parcels located at 8120 S Lovers Lane Rd. (TKNs 801 9986 000, 801 9985 000, 801 9984 000, and 801 9987 000), unofficially known as “Watertower Park,” are the site of a future park proposed by the 2030 Comprehensive Outdoor Recreation Plan (CORP). The City purchased the properties in 2020, and a conceptual site plan for this future park was adopted in 2023. The site is now home to a water tower. Full development of the park will be subject to funding. The property includes significant natural resources including wetland complexes, floodplain, woodland, and areas identified by the Southeast WI Regional Plan Commission (SEWRPC) as Secondary Environmental Corridors. These Environmental Corridors “include the best remaining woodlands, wetlands, prairies, significant wildlife habitat areas, surface water and associated floodplains and riparian buffers, and natural areas and critical species habitat sites, together with many related historic, scenic, and recreational sites (CORP).” NATURAL RESOURCE SPECIAL EXCEPTION REQUEST The requested a Natural Resource Special Exception is for property located at 8120 S Lovers Lane Rd. The property contains wetlands , woodlands , and Secondary Environmental Corridor. This location is an approximately 28 acre site on S. Lovers Lane which is home to one new water tower, and a future park designated by the Comprehensive Outdoor Recreation Plan (Park “PM 2”). The application before the Commission today is a request for a Natural Resource Special Exception (NRSE) to allow for work by the Metropolitan Milwaukee Sewerage District (MMSD) Reforestation and Wetland Restoration Program, in partnership with Ducks Unlimited. The proposed work will result in seven (7) acres of wetland restoration and plant 102 trees in the as yet undeveloped “Watertower Park.” Item C.1 2 Any impact to the Environmental Corridors, including improvement projects, require approval of a Natural Resource Special Exception. The proposed work includes the following: • Planting of 102 trees consisting of oak and other native tree species. • Removal of invasive species, particularly cattails, in the large central wetland complex on the lot. • Mowing of buckthorn. • Creation of a deeper area of wetland to encourage native species. • The addition of an embankment with a weir to manage water levels and connect a future trail. The applicant has provided the attached Natural Resource Special Exception Application, Questionnaire, Project Description, and associated information. The wetland delineation was prepared by an Assured Delineator, and the project has obtained both a DNR General Permit and Army Corps authorization for wetland work. The improvements will be subject to a limited term conservation easement. PARKS COMMISSION RECOMMENDATION Pursuant to Section 15-9-08.B.2.a of the Unified Development Ordinance (UDO), all requests for a Natural Resource Special Exception shall be provided to the Parks Commission for its review and recommendation. That recommendation is then incorporated into the findings and decision of the Plan Commission on the NRSE. Due to a lack of quorum, the regularly scheduled November 9, 2026 Parks Commission meeting did not occur. CONCLUSION Per Section 15-9-08.B.2.a of the Unified Development Ordinance (UDO), the applicant shall have the burden of proof to present evidence sufficient to support a Natural Resource Special Exception (NRSE) request. The applicant has presented evidence for the request by answering the questions and addressing the statements that are part of the Natural Resource Special Exception (NRSE) application. The applicant’s responses to the application’s questions and statements are attached for your review. Usually, there is also attached a recommendation document that the Parks Commission must complete and forward to the Plan Commission. The questions and statements on this document correspond with the Natural Resource Special Exception (NRSE) application questions and statements that the applicant has answered and addressed. Staff recommendations are then incorporated into the draft Parks Commission Recommendation Form as recommended conditions of approval. Due to the cancellation, this document is not available today and the Plan Commission cannot take action on this item. Staff is presenting this material in support of the required Public Hearing, notice of which was published prior to the regularly scheduled Parks Commission meeting. STAFF RECOMMENDATION City Development Staff recommends continuation of the proposed NRSE to a future date of the Commission’s choosing. The next regular meeting after the Parks Commission meeting will be Thursday, December 17, 2026 Attachments: • Applicant materials Planning Department 9229 West Loomis Road (414) 425-4024 generalplanning@franklinwi.gov Franklin, Wisc onsin 53132 Natural Resource Special Exception (NRSE) Question and Answer Form Date: Property Owne r: Property Address: Section 15-9-08.d NRSE Review Criteria The applicant shall have the burden of proof to present evidence sufficient to support the findings required. Criteria for Approval. A Special Exception may be granted only upon a finding by the Plan Commission: i. That the condition(s) giving rise to the request for a Special Exception were not self-imposed by the applicant (this subsection (i) does not apply to an application to improve or enhance a natural resource feature). Applicant Response: ii. Compliance with the strict provisions of this Article will: a. Be unreasonably burdensome to the applicant and that there are no reasonable practicable alternatives; or, b. Unreasonably and negatively impact upon the applicant's use of the property and that there are no reasonable practicable alternatives; and c. The Special Exception, including the specific compensation measures in the Natural Resource Protection Plan and physical modifications to the site to protect other Natural Resources, including any conditions imposed under this Section will: i. Enhance the overall character of the resulting development in a manner consistent with the planned character of the area and site; and ii. Not effectively undermine the ability to apply or enforce the requirement with respect to other properties; and iii. Be in harmony with the general purpose and intent of the provisions of this Article; and iv. Incorporate sufficient monitoring, conditions, and financial sureties to ensure preservation and enhancement of Protected Areas and compensation areas; and v. Preserve or enhance the quality of the natural resources affected. Applicant Response: In making its recommendation, the Plan Commission shall consider factors such as: i. The impact on physical characteristics of the property, including but not limited to, relative placement of improvements thereon with respect to property boundaries or otherwise applicable setbacks; Applicant Response: ii. Any exceptional, extraordinary, or unusual circumstance or conditions applying to the lot or parcel, structure, use, or intended use that do not apply generally to other properties or uses in the same district; Applicant Response: Page | 2 iii. The proposed degree of noncompliance with the requirement of this Article to be allowed by the Special Exception; Applicant Response: iv. The project’s proximity to and character of surrounding property; Applicant Response: v. Purpose of the zoning district of the area in which property is located and neighboring area; Applicant Response: vi. Any potential for negative effects upon adjoining property from the Special Exception if authorized. Applicant Response: Page | 3 7/2026 Water Tower Park Restoration Narrative Ducks Unlimited, Inc. (DU) and Milwaukee Metropolitan Sewerage District (MMSD) were approached by the City of Franklin (the City) to assist with the Water Tower Park restoration through the MMSD Reforestation and Wetland Restoration Program (RWR). Through RWR, MMSD is working with public and private landowners to plant six million trees and restore or enhance 4,000 acres of wetlands in the Greater Milwaukee Watershed. Nature-based solutions such as large-scale reforestation and wetland restoration projects improve the land’s natural capacity to absorb and manage increases in precipitation to reduce flooding, sewer overflows, and basement back-ups while creating economic, social, and environmental benefits now and into the future. Proposals for tree planting and wetland enhancement that were put together by DU, MMSD, and Southeastern Wisconsin Regional Planning Commission were presented to the City. The final, approved plans will enhance 7 acres of wetland and plant 102 trees. The tree species will consist of white oak, swamp white oak, black oak, bur oak, shagbark hickory, and downy arrowwood. The tree planting will improve the diversity in the dry-mesic woods. The wetland enhancement will create a shallow scrape on the north end of the existing wetland. This will create a deeper pocket of water to provide microtopography in the wetland, which is currently dominated by hybrid cattails. The borrow material from the scrape will be used to create an embankment on the north end of the wetland. A water control structure placed in the embankment will allow the City to manage water levels to benefit the habitat. While cattails will likely continue to be the dominant species, the scrape and ability to hold higher water levels will allow native submergent and emergent vegetation a better chance to establish. The embankment will also serve as the crossing over the wetland in the future trail plans. Excess borrow material will be spread on uplands in the southwest corner and seeded. Additionally, invasive buckthorn surrounding the wetlands will be managed with brush mowing. There is a native tussock sedge meadow community under the buckthorn that will benefit from the invasive shrub’s removal. The City agreed to be a partner in the National Fish and Wildlife Foundation Sustain our Great Lakes (NFWF SOGL) grant proposal to restore wetlands and plant trees in the Greater Milwaukee Watershed to secure funding for the restoration work. The NFWF SOGL agreement ends June 30, 2027. Proposed timeline for current work is to complete wetland enhancement in October/November 2026, brush mow buckthorn in winter 2026/27 when the ground is frozen, and tree planting will occur in Spring 2027. Future maintenance of the project site will be handled by the City. The project will help to the City to meet some of their proposed habitat improvements for Water Tower Park. Service Layer Credits: Latest Leaf Off: , DNR Detailed Feature VTL (WTM): , County Tax Parcels (Dynamic): , County Tax Parcels (Cached): , Wetland Inventory NWI: Calvin Lawrence, Dennis Weise, Nina Rihn ´ Date Printed: 9/19/2026 10:55 AM Map Location Notes: Map projection: NAD 1983 HARN Wisconsin TM Legend: (some map layers may not be displayed) This map is a product generated by a DNR web mapping application. This map is for informational purposes only and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. The user is solely responsible for verifying the accuracy of information before using for any purpose. By using this product for any purpose user agrees to be bound by all disclaimers found here: https://dnr.wisconsin.gov/legal. Wetland Class Points Wetland too small to delineate Wetland Class Areas Wetland Identifications and Confirmations Waterway and Wetland Alterations Cities, Towns & Villages City DOA Statewide Parcel Map Database Project Latest Leaf Off Index Latest Leaf Off Imagery Map: 0 150 300 Feet 0 40 80 Meters Water Tower Park Wetlands SE Wisc Reg Planning Comm, SEWRPC, Microsoft, Vantor Map X.X Wat er Tower Park Management Units Source: SEWRPC 0 100 20050 Feet Management Unit 1 2 3 4 5 6 Degraded shallow, cattail marsh Dogwood-willow shrub meadow Dry-mesic woods Tussock sedge meadow Not included in SEWRPC assessment Water Tower, access, & parking area MAIL MAIL GUY GUY GUY IP MAIL SAN MH IP IP SITE CALCULATIONS TOTAL AREA OF LOT = 933,634 SQ FT = 21.43 ACRES WETLAND = 278,710 SQ FT = 6.40 ACRES WETLAND BUFFER = 204,116 SQ FT = 4.69 ACRES YOUNG WOODLAND = 49,335 SQ FT = 1.13 ACRES DRIVE, WATER TOWERS AND STORMWATER POND = 50,540 SQ FT = 1.16 ACRES REMAINING LAND FOR USE= 8.05 ACRES TRAIL LENGTH = 1/2 MILE LOOP WATER TOWER PARK CITY OF FRANKLIN SITE ANALYSIS/CONCEPT LAYOUT --- SHEET NUMBER Brookfield, WI | Milwaukee, WI | Appleton, WI | Madison, WI Cedarburg, WI | Naperville, IL | Irvine, CA 25 50 100 GRAPHIC SCALE 0 NORTH P:\3220173\Dwg\3220173_H0.dwg, Plan Sheet 36x24, 12/4/2023 1:58:27 PM, rew OAK OAK, SHAGBARK, & BLACK CHERRY. BUCKTHORN GROUND LAYER STAND OF PINE Thick Brush EXISTING DENSE VEGETATION - GOOD SCREEN WETLAND FILLED WITH CATTAILS GOOD OPEN HIGH SPOT WITH VIEWS NICE WETLAND - NO CATTAILS Quaking Aspen OAK OAK Black Walnut POSSIBLE GOOD VIEWS IF ELEVATED WETLAND 2 WETLAND 2 WETLAND 3 WETLAND 5 WETLAND 6 WETLAND 7 EXISTING DIRT PATH WETLAND 1 THIN EXISTING VEGETATION - ADD EVERGREEN SCREENING OR FENCE SPRUCE, PINE, & BLACK WALNUT WETLAND 4 EXISTING DENSE VEGETATION - GOOD SCREEN POSSIBLE WETLAND CROSSING POSSIBLE WETLAND CROSSING POSSIBLE WETLAND CROSSING POSSIBLE PARKING AREA POSSIBLE RESTROOM POSSIBLE PARKING AREA POSSIBLE RESTROOM POSSIBLE TRAIL ROUTE POSSIBLE TRAIL ROUTE GROUND LAYER OF BUCKTHORN GROUND LAYER OF BUCKTHORN GROUND LAYER OF BUCKTHORN GROUND LAYER OF BUCKTHORN NICE WETLAND - MINIMAL CATTAILS GROUND LAYER OF BUCKTHORN GROUND LAYER OF BUCKTHORN 30' WETLAND SETBACK WETLANDS ARE NUMBERED PER WETLAND DELINEATION REPORT PREPARED BY raSmith DECEMBER 7, 2020 POSSIBLE TRAIL ROUTE TO EAST POSSIBLE TRAIL ROUTE TO HWY 100 WETLAND 8 45 45 45 S Lovers Lane Rd S 100th StS 100 th St W Loomis Rd Sources: Esri, TomTom, Garmin, FAO, NOAA, USGS, © OpenStreetMap contributors, and the GIS User Community Legend PlantingPlan Description Spoil Spreading Area Tree Planting - Area 1 Tree Planting - Area 2 Tree Planting - Area 3 0 0.01 0.03 0.04 0.060.01 Miles ¯ Description Species Spacing Acres TotalTrees Tree Planting - Area 1 White Oak, Swamp White Oak, Black Oak, Bur Oak, Shagbark Hickory, Downy Arrowwood 50 ft 4.40 75 Tree Planting - Area 2 White Oak, Swamp White Oak, Black Oak, Bur Oak, Shagbark Hickory, Downy Arrowwood 50 ft 1.35 23 Tree Planting - Area 3 White Oak, Swamp White Oak, Black Oak, Bur Oak, Shagbark Hickory, Downy Arrowwood 50 ft 0.27 4 Spoil Spreading Area None NA 0.78 0 City of Franklin - Water Tower Park Planting Map FRANKLIN WATER TOWER T5N, R21E, SECTION 17, TOWNSHIP OF FRANKLIN MILWAUKEE COUNTY, WISCONSIN IN COOPERATION WITH MILWAUKEE COUNTY PARKS PROJECT LOCATION R Know what's below. Call before you dig. NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. PROJECT LOCATION MAP SCALE: NOT TO SCALE AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C001 COVER AND SPECS.dwg, 8/11/2026 10:21 AM, Benjamin Monty, COVER, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C001 8/11/2026 TH MS MLH BE WI-410-104 C001 COVER AND SPECS FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI COVER US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - PROJECT LOCATION WISCONSIN Sheet List Table Sheet Number Sheet Title C001 COVER C002 SPECIFICATIONS AND NOTES C051 TOPOGRAPHIC SURVEY C101 SITE PLAN C102 SITE PLAN - PIPES & TRAILS C201 PROFILES C202 CROSS SECTIONS C301 WCS 1 C302 WCS 2 C303 GRAVEL PATH & TRASH RACK DETAILS SPECIFICATIONS 101 GENERAL CONDITIONS 102 SUPPLEMENTAL CONDITIONS 201 MOBILIZATION 202 SITE PREPARATION 203 EXCAVATION 204 EMBANKMENT CONSTRUCTION 205 CONSTRUCTED TOPOGRAPHY 301 WATER CONTROL STRUCTURES 302 STRUCTURE AND CULVERT APPURTENANCES 303 CULVERT AND PIPE INSTALLATION 305 RIPRAP, REVETMENT AND AGGREGATE PLACEMENT 401 SOIL EROSION AND POLLUTION CONTROL 402 SEEDING AND MULCHING NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C001 COVER AND SPECS.dwg, 8/11/2026 10:21 AM, Benjamin Monty, SPECIFICATIONS AND NOTES, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C002 8/11/2026 TH MS MLH BE WI-410-104 C001 COVER AND SPECS FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI SPECIFICATIONS AND NOTES US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - CONSTRUCTION NOTES: 1. BID ITEM FOR MOBILIZATION SHALL INCLUDE THE SUPPLY OF ALL LABOR, MATERIAL AND EQUIPMENT TO TRANSPORT ALL NEEDED LABOR, MATERIAL AND EQUIPMENT, TO AND FROM A PROJECT SITE, TO SUCCESSFULLY COMPLETE THAT PROJECT AS SHOWN ON THE PLANS. SITE WILL NEED TO BE ACCESSED FROM HIGHWAY 100, NO ACCESS IS ALLOWED FROM EAST/WEST SIDE ROAD ON NORTH END OF SITE DUE TO NEW PAVEMENT. APPLICABLE STATE PERMITS FOR ACCESS WILL NEED TO BE OBTAINED IF NECESSARY. 2. THE PAY QUANTITY FOR THE SITE PREPARATION BID ITEM SHALL INCLUDE STRIPPING EMBANKMENT AREA AND POND AREA, STOCKPILING TOPSOIL FOR REPLACEMENT (573 CU. YDS. STRIPPED), PLACING TOPSOIL OVER ALL DISTURBED AREAS, AND LEVELED SUITABLE ENOUGH FOR SEEDING. GRUBBING OF BRUSH OR TREES FOR EARTHWORK PREPARATION IS ALSO INCLUDED. 3. BID ITEM FOR OBSTRUCTION REMOVAL INCLUDES CLEARING A PATH AS NECESSARY FOR SITE ACCESS. ALL CLEARED MATERIAL WILL BE PLACED IN A SPOIL DISPOSAL AREA AS AGREED TO WITH TECHNICIAN OR PLACED IN SCRAPE POND FOR HABITAT. 4. BID ITEM FOR BERM FILL SHALL INCLUDE ALL WORK REQUIRED TO EXCAVATE, HAUL, PLACE, AND COMPACT FILL MATERIAL TO CONSTRUCT EARTHWORK, AS STAKED IN THE FIELD. 5. BID ITEM FOR SPOIL SPREADING INCLUDES SPREADING OF THE EXCESS EXCAVATED MATERIAL FROM THE SCRAPE POND IN THE DESIGNATED SPOILS DISPOSAL AREA. SPOILS SHALL BE SPREAD A MAXIMUM THICKNESS OF 2.0' AND MINIMUM 8:1 SIDE SLOPES. 6. BID ITEM FOR INSTALLATION OF AN AGRI-DRAIN WATER CONTROL STRUCTURE SHALL INCLUDE PURCHASE AND INSTALLATION OF THE STRUCTURE, AS PER SPECIFICATIONS, ALONG WITH PROVIDING ALL OF THE APPURTENANCES 7. BID ITEM FOR INSTALLATION OF 18" PVC PIPE SHALL INCLUDE PURCHASE AND INSTALLATION , AS PER SPECIFICATION 303, ALONG WITH PROVIDING ALL OF THE APPURTENANCES. 8. THE BID ITEM FOR ROAD GRAVEL ALONG THE PROPOSED TRAIL & EMBANKMENT SHALL INCLUDE PURCHASE AND INSTALLATION OF ALL MATERIALS NEEDED TO INSTALL AGGREGATE. 9. THE BID ITEM FOR ROCK RIPRAP AROUND INLET AND OUTLET OF PIPE SHALL INCLUDE PURCHASE AND INSTALLATION OF ALL MATERIALS NEEDED TO INSTALL ROCK. 10. THE BID ITEM FOR TRASH RACK AROUND INLET OF PIPE SHALL INCLUDE PURCHASE AND INSTALLATION OF ALL MATERIALS NEEDED INSTALL THE TRASH RACK. 11. THE BID ITEM FOR SOIL EROSION AND POLLUTION CONTROL SHALL INCLUDE THE SUPPLY AND INSTALLATION OF STRAW WATTLES. 12. THE BID ITEM FOR SEEDING AND MULCHING INCLUDES SEEDING BERM FILL AND DISTURBED AREAS TO SPECIFIED SEED MIX IMMEDIATELY AFTER CONSTRUCTION. MULCHING WILL ONLY BE REQUIRED ON THE BERM FILL. 13. DEWATERING AND WATER MAINTENANCE IS THE CONTRACTOR'S RESPONSIBILITY, AND IS CONSIDERED INCIDENTAL TO THE PROJECT. STRAW WATTLE LENGTH---- 80 LIN.FT. SUPPORT POSTS------- AS NEEDED EA. 1. USE WOOD STAKES A MINIMUM SIZE OF 1 18" X 118" X18" LONG. USE ONE STAKE EVERY 6 FEET. BUTT ENDS OF ROLL TOGETHER DO NOT OVER LAP. STRAW WATTLE ESTIMATED BID QUANTITIES BID ITEM NOTE SPEC # DESCRIPTION UNIT QUANTITY 1 1 201 MOBILIZATION LS 1 2 2 202 SITE PREPARATION LS 1 3 3 202 OBSTRUCTION REMOVAL AC-P 0.2 4 4 205 FILL BERMS CY-P 294 5 5 205 SPOIL SPREADING CY-P 1206 6 6 301 AGRI-DRAIN WATER CONTROL STRUCTURE EA 1 7 7 303 PVC PIPE 18" LN FT 46 8 8 305 ROAD GRAVEL TN 73 9 9 305 ROCK RIPRAP TN 19.5 10 10 N/A TRASH RACK EA 1 11 11 401 SOIL EROSION AND POLLUTION CONTROL - STRAW WATTLES LN FT 80 12 12 402 SEEDING MULCHING AC-P 1 1104 24" w/ T/PIPE: 785.78 790 790 795 800 800 800 786 786787 787 788 788 789 789 791 791 792 792 793 793 794 796797798 799 799 799 801 801 801 802 802 802 803 803 803 804 790 795 786 787 788 789 791 792 793 794 790 795 786786 787 788789 791 792 793794 796797798 799 790 795 786 787 788 789 791 792 793 794 796 797 1107 30" RCP w/FES T/PIPE: 801.00 GOOD 1108 30" RCP w/FES I.E.: 798.84 GOOD 1110 30" RCP w/FES I.E.: 801.30 GOOD 1111 30" RCP w/FES T/PIPE: 803.02 GOOD EXISTING CULVERT TO REMAIN IN PLACE AND UNDISTURBED PROPOSED STAGING AREA PROPOSED ACCESS ROUTE FROM HIGHWAY 100 PROPOSED OBSTRUCTION REMOVAL 0.2 ACRES 20' OCTOBER 18, 2024 US-WI-410-104, FRANKLIN WATER TOWER PARK COORDINATES ARE NSRS2011, WISCONSIN COUNTY CRS: MILWAUKEE-F [WISCRS-MIL-F] PROJECTION: TM DATUM: NSRS11 NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. LEGEND DIKE ℄ CHANNEL ℄ DITCH ℄ MAJOR CONTOUR MINOR CONTOUR 000 000 R Know what's below. Call before you dig. GRAPHIC SCALE 1 inch = feet50 50 0 25 50 100 200 PROPOSED OBSTRUCTION REMOVAL AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C051 TOPOGRAPHIC SURVEY.dwg, 8/11/2026 10:21 AM, Benjamin Monty, TOPOGRAPHIC SURVEY, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C051 8/11/2026 TH MS MLH BE WI-410-104 C051 TOPOGRAPHIC SURVEY FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI TOPOGRAPHIC SURVEY US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - EXISTING PIPE 1104 24" w/ T/PIPE: 785.78 1107 30" RCP w/FES T/PIPE: 801.00 GOOD 1108 30" RCP w/FES I.E.: 798.84 GOOD 1110 30" RCP w/FES I.E.: 801.30 GOOD 1111 30" RCP w/FES T/PIPE: 803.02 GOOD 3:1 BACK SLOPE 5:1 FRONT SLOPE 20' BOTTOM ELEV. 784.0 8:1 8:1 8:1 8:1 FS12 FS12 FS12 STRAW WATTLE PROPOSED SPOILS DISPOSAL AREA MAX FILL HEIGHT OF 2', 8:1 MINIMUM SIDE SLOPES 0+001+00 2+00 3+00 4+00 5+00 5+75 0+00 1+00 2+002+00 PROPOSED AGRIDRAIN STRUCTURE SEE SHEETS C301 & C302 PROPOSED TRAIL & EMBANKMENT SEE SHEET C303 PROPOSED BORROW SCRAPE SEE SHEET C201 TOP ELEV. 787.8 12' GRAPHIC SCALE 1 inch = feet50 50 0 25 50 100 200 LEGEND APPROXIMATE PROPERTY LINE PROPOSED DIKE PROPOSED CHANNEL/DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED AGRIDRAIN STRUCTURE PROPOSED PIPE (000) (000) PROPOSED STRAW WATTLE PROPOSED SPOIL AREA PROPOSED GRAVEL R Know what's below. Call before you dig. NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C101 SITE PLAN.dwg, 8/11/2026 10:21 AM, Benjamin Monty, SITE PLAN, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C101 8/11/2026 TH MS MLH BE WI-410-104 C101 SITE PLAN FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI SITE PLAN US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - FS12 EXISTING CULVERT VAN 0+001+00 2+00 3+00 4+00 5+00 5+75 0+00 1+00 2+002+00 PROPOSED TRAIL & EMBANKMENT PROPOSED BORROW SCRAPE WATER TOWERS PROPOSED SPOILS DISPOSAL AREA PLANNED TRAIL PLANNED PARKING LOT GRAPHIC SCALE 1 inch = feet50 50 0 25 50 100 200 LEGEND APPROXIMATE PROPERTY LINE PROPOSED DIKE PROPOSED CHANNEL/DITCH PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED AGRIDRAIN STRUCTURE PROPOSED PIPE (000) (000) PROPOSED STRAW WATTLE PROPOSED SPOIL AREA PROPOSED GRAVEL R Know what's below. Call before you dig. NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C101 SITE PLAN_ParksOverlay.dwg, 8/11/2026 10:21 AM, Benjamin Monty, SITE PLAN - PIPES & TRAILS, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C102 8/11/2026 TH MS MLH BE WI-410-104 C101 SITE PLAN_ParksOverlay FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI SITE PLAN - PIPES & TRAILS US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - FS12 EXISTING CULVERT CU WATERLINE - E CU WATERLINE - N OFFSITE WATERLINE - WISCOR PLANNED TRAILS STA: 0+00 TO 2+00 PROFILE SITE 1 775 780 785 790 795 775 780 785 790 795 786.8 0+00 787.4 787.4 0+50 783.8 784.1 1+00 784.4 785.4 1+50 786.0 787.8 786.0 2+00 3:1 5:1 TOP BERM ELEV. 787.8 STRIPPING EXISTING GROUND 20'TOP EXISTING 24" PIPE ELEV. 785.78 STA: 2+00 TO 4+00 PROFILE SITE 1 775 780 785 790 795 775 780 785 790 795 786.0 2+00 786.0 786.0 2+50 783.9 785.9 783.9 785.3 3+00 783.9 785.1 783.9 785.5 3+50 783.9 785.8 783.9 786.0 4+00 783.9 STRIPPING EXISTING GROUNDBOTTOM POND ELEV. 784.0 8:1 STA: 4+00 TO 5+75 PROFILE SITE 1 775 780 785 790 795 775 780 785 790 795 786.0 4+00 783.9 786.0 783.9 786.0 4+50 783.9 786.0 783.9 786.0 5+00 783.9 786.0 784.0 786.0 5+50 5+75 STRIPPING EXISTING GROUND BOTTOM POND ELEV. 784.0 8:1 3:1 BACK SLOPE 5:1 FRONT SLOPE 20' FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 FS12 STRAW WATTLE 1+00 2+00 0+00 1+00 2+002+00 PROPOSED AGRIDRAIN STRUCTURE SEE SHEETS C301 & C302 PROPOSED TRAIL & EMBANKMENT SEE SHEET C303 TOP ELEV. 787.8 12' NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C101 SITE PLAN.dwg, 8/11/2026 10:21 AM, Benjamin Monty, PROFILES, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C201 8/11/2026 TH MS MLH BE WI-410-104 C101 SITE PLAN FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI PROFILES US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - VERTICAL SCALE 1 inch = feet 0 HORIZONTAL SCALE 1 inch = feet 0 10 205 10 10 10 205 10 10 GRAPHIC SCALE 1 inch = feet10 10 0 5 10 20 40 STA: 0+00 TO 2+00 PROFILE BERM 780 785 790 795 780 785 790 795 789.5 0+00 787.7 787.8 786.6 0+50 787.8 786.0 787.8 786.0 1+00 787.8 786.7 787.8 787.5 1+50 787.8 788.3 789.0 2+00 789.0 2+00 STRIPPING EXISTING GROUND TOP BERM ELEV. 787.8 18" PIPE GEOTEXTILE FABRIC 6" OF TRAFFIC BOND MATERIALTOP OF RISER ELEV. 789.0 WEST EAST TYPICAL CROSS SECTION 2+75.00 775 780 785 790 795 775 780 785 790 795 100 80 60 40 20 0 20 40 60 80 100 STRIPPING EXISTING GROUND BOTTOM POND ELEV. 784.0 8:1 8:1 WEST EAST TYPICAL CROSS SECTION 4+00.00 775 780 785 790 795 775 780 785 790 795 100 80 60 40 20 0 20 40 60 80 100 STRIPPING EXISTING GROUND BOTTOM POND ELEV. 784.0 8:1 8:1 WEST EAST TYPICAL CROSS SECTION 4+80.00 775 780 785 790 795 775 780 785 790 795 100 80 60 40 20 0 20 40 60 80 100 STRIPPING EXISTING GROUND BOTTOM POND ELEV. 784.0 8:1 8:1 WEST EAST STA: 1+25 TO 2+25 PROFILE SITE 1 775 780 785 790 795 775 780 785 790 795 784.4 1+25 785.4 1+50 785.3 786.0 787.8 786.0 2+00 786.0 2+25 3:1 5:1 GEOTEXTILE FABRIC STRIPPING EXISTING GROUND 20' 40'2' 6' 2' TOP RISER ELEV. 789.0 OUTLET ELEV. 784.7 INLET ELEV. 785.0 6" OF TRAFFIC BOND MATERIAL TOP BERM ELEV. 787.8 18" PVC PIPE 12' ROCK AROUND INLET 8.5 TONS ROCK AROUND OUTLET 6.5 TONS GEOTEXTILE FABRICGEOTEXTILE FABRIC DOWNSTREAM END IMPOUNDMENT SIDE NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C101 SITE PLAN.dwg, 8/11/2026 10:21 AM, Benjamin Monty, CROSS SECTIONS, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C202 8/11/2026 TH MS MLH BE WI-410-104 C101 SITE PLAN FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI CROSS SECTIONS US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - VERTICAL SCALE 1 inch = feet 0 HORIZONTAL SCALE 1 inch = feet 0 10 205 10 10 10 205 10 10 VERTICAL SCALE 1 inch = feet 0 HORIZONTAL SCALE 1 inch = feet 0 10 205 10 10 10 205 10 10 VERTICAL SCALE 1 inch = feet 0 HORIZONTAL SCALE 1 inch = feet 0 5 102.5 5 5 5 102.5 5 5 WCS STRUCTURE STR-1 18" 24"x28" 787.8' 789.0' 786.2' 785.0' 784.7' 20' 40.0' 6.0' 11.17' 4.0' IMPOUNDMENT SIDE 18" PVC PIPE EXISTING GRADE ℄ OS ℄ STRUCTURE ℄ DIKE PROFILE OF AGRI-DRAIN WATER CONTROL STRUCTURE PIPE SIZE RISER SIZE TOP OF DIKE EL. "A" TOP OF RISER EL. "B" FULL SERVICE LEVEL INLET I.E. EL. "C" OUTLET I.E. EL. "D" TOP WIDTH "W" INLET LENGTH "LI" OUTLET LENGTH "L2" ℄ - ℄ OFFSET RISER HEIGHT "H" PROPOSED GRADE TOP OF DIKE AT THE CROWN ELEV. "A" PROPOSED STONE RIP-RAP DOWNSTREAM INVERT ELEV. "D" TOP OF RISER ELEV. "B" UPSTREAM INVERT ELEV. "C" CULVERT ANCHORCULVERT ANCHOR CULVERT ANCHOR R "H" "W" "L1""L2" NOT TO SCALE EXISTING GRADE RIPRAP 4 NUMBER OF BOARDS 2:1 SLOPE PIPE TYPICAL SECTION VARIES 2:1 SLOPE 1 PIPE DIA. 1 PIPE DIA. 6" 3' 3/4"Ø 1/4" S.S. CABLE CULVERT ANCHOR PIPE INSTALLATION & REMOVAL DETAIL NOT TO SCALE NOT TO SCALE CABLE CLAMPS 2 REQUIRED (MINIMUM) PLACE RODENT GUARD AT END OF PIPE PLACE TRASH RACK AROUND END OF PIPE ROCK RIPRAP 19.5 TNS GEOTEXTILE 45 SQ YDS NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C301 DETAILS.dwg, 8/11/2026 10:21 AM, Benjamin Monty, WCS 1, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C301 8/11/2026 TH MS MLH BE WI-410-104 C301 DETAILS FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI WCS 1 US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - INLET STRUCTURE SIZING CHART OUTLET "F" "I" "G" WIDTH "D" DEPTH "C" "A" "B" "B" "A" DOWNSTREAM H-CHANNEL UPSTREAM (DRAWN WITH FERNCO 1056 COUPLER) NOT TO SCALE "E" 1" PIPE DIA. BACK VIEW NOT TO SCALE BACK VIEW BOTTOM VIEW END VIEWS FRONT VIEW FRONT VIEW BOTTOM VIEW END VIEWS "H" TOP VIEW TOP VIEW R AGRI-DRAIN INLINE WATER LEVEL CONTROL STRUCTURE DETAIL PLAN VIEW SECTION "A"-"A" SECTION "B"-"B" STOPLOG DETAIL 24" 4" 6" 8" 10" 12" 15" 18" 7" 7" 7" 7" 7" 7" 7" 7"30.75" 23.75" 19.75" 15.75" 13.75" 11.75" 7.75" 7.75" 5" 5" 5" 5" 5" 5" 5" 5"8" 8" 12" 14" 16" 20" 24" 31" 39" 28" 24" 20" 16" 12" 10" 10" 29.00" 21.70" 17.85" 12.83" 10.60" 8.50" 6.38" 4.42" 4.42" 6.38" 8.50" 10.60" 12.83" 17.85" 21.70" 29.00" 17.5" 17.5" 23.5" 27.5" 31.5" 43.5" 47.5" 58.5" 7.75" 7.75" 11.75" 13.75" 15.75" 19.75" 23.75" 30.75" INSIDE DIM. WIDTH DEPTH COUPLING DIM. "C" (I.D.) "D" (I.D.) "E" "F" "I" "H""G" HEIGHT STOPLOG DIM. WIDTH COUPLING LENGTHPIPE* DIA. * ALL APPLICATIONS WILL UTILIZE EITHER SCHEDULE 40 PVC PIPE OR DUAL WALL ADS N-12 WATER TIGHT PIPE OR APPROVED EQUAL FOR ATTACHMENT TO INLINE WATER CONTROL STRUCTURE NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C301 DETAILS.dwg, 8/11/2026 10:21 AM, Benjamin Monty, WCS 2, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C302 8/11/2026 TH MS MLH BE WI-410-104 C301 DETAILS FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI WCS 2 US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - NOTICE: CONSTRUCTION SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DUCKS UNLIMITED, INC. SHALL NOT ASSUME ANY RESPONSIBILITY FOR THE SAFETY OF THE WORK PERFORMED, PERSONS ENGAGED IN THE WORK, NEARBY STRUCTURES, OR OF OTHER PERSONS ON-SITE. THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A LICENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT AND INCLUDE THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AFFIX SEAL: DUCKS UNLIMITED, INC. ON: GREAT LAKES/ATLANTIC REGIONAL OFFICE 7322 NEWMAN BOULEVARD, BUILDING 2, STE. 200 DEXTER, MICHIGAN 48130 (734) 623-2000 www.ducks.org C:\Users\bmonty\Ducks Unlimited Incorporated\GLARC3D - WI\WI0410104 Franklin Water Tower\C3D_DRAWING\WI-410-104 C301 DETAILS.dwg, 8/11/2026 10:21 AM, Benjamin Monty, GRAVEL PATH & TRASH RACK DETAILS, None CAD FILE: DESIGNED BY: DRAWN BY: SURVEYED BY: BIOLOGIST: DATE: PROJECT NUMBER: Revisions Date ByRevision Sheet C303 8/11/2026 TH MS MLH BE WI-410-104 C301 DETAILS FRANKLIN WATER PARK FRANKLIN MILWAUKEE COUNTY, WI GRAVEL PATH & TRASH RACK DETAILS US-WI-410-104 -- - - - --- - - --- - - --- - - --- - - --- - - TRAFFIC BOND MATERIAL OVER GEOTEXTILE ACCESS ROAD CROSS-SECTION TRAFFIC BOND ESTIMATED ROAD LENGTH QUANTITY ESTIMATE CUBIC YARDS FEET CLASS I GEOTEXTILE MATERIAL - WCS 13 SQUARE YARDS ACCESS ROAD CONSTRUCTION · LOCATE ROAD ON WELL TO SOMEWHAT POORLY DRAINED SOILS. · AVOID LONG STEEP SLOPES. · KEEP ROAD GRADE <10%. · CONSTRUCT ROAD ABOVE NATURAL GROUND FOR BETTER DRAINAGE. · REMOVE TREES AND BRUSH ONLY IN THE PROPOSED ROAD AREA. · CRUSHED STONE CRITERIA: 100% PASSING 3/4 INCH SIEVE AND 10% MAXIMUM PASSING THE #200 SIEVE. · ENSURE THE GEOTEXTILE ENVELOPES THE CRUSHED STONE BY LAYING ALONG THE ENTIRE BOTTOM AND UP THE SIDES. 6" MINIMUM THICKNESS CRUSHED STONE CLASS I GEOTEXTILE BURY EDGES 1' FOR ANCHORAGE PATH OVER BERM 12' WIDE 5:1 3:1 178 52 (73 TONS) 280 CROWN IN MIDDLE AND 5% PITCH EACH WAY DOWN TO BERM TOP OF BERM 20' WIDE TOP OF BERM AT THE CROWN ELEV. 787.8 TYPICAL WETLAND BORROW SITE CROSS SECTION WETLAND BORROW SITE PLAN VIEW NOTE: PERIMETER WILL BE CURVILINEAR IN SHAPE. DEPTH = 0.5' TO 4.0' MAX. EXISTING GROUND WATER LEVEL (FLUCTUATES) VARY SIDE SLOPES 8:1 OR FLATTER ON ALL SIDES ROUGH BOTTOM AND VARYING DEPTH 8:1 SIDE SLOPES WITH A ROUGH BOTTOM NOTES: 1. SCRAPES/BORROW AREAS WILL BE CONSTRUCTED AT LOCATIONS AS FLAGGED BY THE TECHNICIAN. 2. SCRAPES ARE TO BE IRREGULAR IN SHAPE WHEN COMPLETED. WHEEL RUTS ARE ALLOWED AND DESIRED. 3. CONSTRUCTION SPECIFICATION 203, EXCAVATION, SHALL BE FOLLOWED. 4. STRIP MINIMUM 6" OF TOPSOIL AND STOCKPILE IT FOR SPREADING, IF NEEDED, AFTER THE EXCAVATION IS COMPLETED. 5. SPOIL SHALL BE DISPOSED OF AT DESIGNATED SPOIL DISPOSAL AREA PER PLAN VIEW. NO SCALE NO SCALE SIDE ELEVATION 4' Detail A Approx. 2' Deep POST ANCHORAGE PLANVIEW STANDARD DETAIL A Fill Surface Post 18" Approx. 2' Place larger openings to bottom. Panel Height Wire Loops INLET SIDE OF WATER CONTROL STRUCTURE DETAILS OF TRASH RACK Panel Panel 18" PVC PIPE Steel"T" Post Steel"T" Post Steel"T" Post 4' 4' Steel"T" Post 4' Embankment NOTES: 1. MINIMUM HEIGHT OF PANEL TO BE 3 FEET. THE MINIMUM LENGTH OF STEEL POSTS SHALL BE 5 FEET. 2. THE PANELS SHALL BE FASTENED TO EACH POST WITH A MINIMUM OF 2 STRANDS PER LOOP OF 10 GAGE INSULATED COPPER WIRE SECURELY TWISTED OR STAINLESS STEEL HOSE CLAMPS. SPACING OF WIRE LOOPS SHALL NOT EXCEED 2 FEET WITH MINIMUM 2 LOOPS PER POST. 3. PANELS (SOLD AS HOG OR CATTLE PANELS) SHALL BE 1/4'" GALVANIZED STEEL RODS WELDED TOGETHER TO FORM A PANEL. MAXIMUM SPACING OF RODS SHALL BE 6 INCHES VERTICAL AND 8 INCHES HORIZONTAL. NOT TO SCALE 1 CITY OF FRANKLIN REPORT TO THE PLAN COMMISSION Meeting of November 19, 2026 Site Plan RECOMMENDATION: City Development Staff recommends approval of the proposed Site Plan, subject to the conditions of approval in the attached draft resolution. Project Name: SixSibs Capital Site Plan Property Owner: Franklin Industrial II, LLC Applicant: Patrick Noonan, SixSibs Capital Property Address/Tax Key Number: 10651 S HICKORY ST / (TKN 950 9002 000) Aldermanic District: District 4 Agent: Scott Maier Pinnacle Engineering Group Zoning District: Planned Development Legacy (PDL) 39 Staff Planner: Marion Ecks, AICP The applicant’s request is for approval of a Site Plan to allow for development of two 128,000 square foot industrial buildings with related truck and passenger parking. Site access will be off of S. Hickory. Developments over 20,000 square feet of floor area require Plan Commission approval. CHARACTER OF THE SITE AND SURROUNDING AREA The subject property is zoned Planned Development Legacy (PDL) 39. The lot was created by a Certified Survey Map which divided this property from the parcel to the north (3617 W Oakwood) in 2022. Prior to being divided, this lot received approval of a Natural Resource Special Exception for impacts to wetland resources, and includes a natural resource compensation area and conservation easement, along with pre-existing stormwater features. It has also received Special (Conditional) Use approval of overnight truck parking (RES 2021-7722) which applies to this parcel. The property is currently vacant, except for WE Energies transmission lines which occupy the west and south property line. Developments under these transmission lines are governed by an easement. The surrounding area includes industrial properties to the southeast; Milwaukee County parklands to the west; and vacant lands to the east including two lots owned by WE Energies. The southern property line is across from the western extent of Elm Road. PROJECT ANALYSIS The applicant has submitted all required elements for site plan review. The site design and structure meets the dimensional requirements of the PDL 39 zoning district in terms of building height, setbacks, impervious coverage etc. Item E.1. 2 The Site Plan proposes two 128,000 square foot buildings designed for industrial uses, with 84 truck parking spaces between and behind buildings. The site includes 212 passenger parking spaces which comply with size requirements, and bicycle parking. The applicants are questing a waiver of the PDL requirement to provided markings or pedestrian facilities within the passenger parking areas. No charging stations for electric vehicles are proposed. The landscape plan is generally in compliance with the PDL and the Unified Development Ordinance (UDO), offering foundation plantings and appropriate plant quantities. However, due to the presence of the high-tension power lines at the rear of the lot, the applicant is unable to meet the buffering requirements of the PDL and UDO. This will necessitate a waiver of this PDL design standard, as well as a variance. Staff notes that: • No new impacts to natural resources or encroachment into the existing conservation easement are proposed. • Stormwater will be conveyed to the existing shared pond. • Lighting complies with UDO requirements. The development is unable to meet some design requirements of the PDL and UDO, and have therefore requested waivers and/or a variance for: Request for PDL 39 Design Waivers for: Plan Commission may waive PDL Design requirements. These requests are reflected in the draft resolution: • Large [passenger] parking areas shall include walkways to allow safe pedestrian access to the building entrance • A bufferyard and buffering plantings are required in rear of the development (west property line) BZBA Variance for: The Board of Zoning and Building Appeals may grant a variance for design items not regulated by the PDL. Staff recommends that this Site Plan approval be conditioned upon a variance for: • A bufferyard and buffering plantings are required in rear of the development (west property line) (§15-5-03.C, and §15-5-04.C) • The width of any continuous flat roofline should not extend more than one hundred (100) feet without modulation. For flat roofs the minimum vertical dimension of roofline modulation is the greater of two (2) feet or ten (10) percent of the wall height. • Glazing is required on the S. Hickory facades in what is called the “transparency zone”. The minimum required percentage of square footage in the transparency zone that must have a glazing treatment is 30%. (§15-5-10.E). The development will need a variance of material standards. STAFF RECOMMENDATION City Development Staff recommends approval of the proposed Site Plan, subject to the conditions of approval in the attached draft resolution. Attachments: • Site Plan RES • Applicant Plan Commission Package STATE OF WISCONSIN CITY OF FRANKLIN MILWAUKEE COUNTY PLAN COMMISSION [Draft 11-11-2026] RESOLUTION NO. 2026-_____ A RESOLUTION APPROVING A SITE PLAN FOR THE DEVELOPMENT OF TWO 128,000 SQUARE FOOT INDUSTRIAL BUILDINGS WITH RELATED TRUCK AND PASSENGER PARKING, UPON PROPERTY LOCATED AT 10651 S HICKORY ST / (TKN 950 9002 000) (SIXSIBS CAPITAL DEVELOPMENT, APPLICANT) (FRANKLIN INDUSTRIAL II, LLC, PROPERTY OWNER) WHEREAS, SixSibs Capit al Development having applied for approval of two 128,000 square foot industrial buildings with related truck and passenger parking upon property located at 10651 S Hickory St., (TKN 950 9002 000); and WHEREAS, the Plan Commission having reviewed such proposal and having found same to be in compliance with the applicable terms and provisions of the Unified Development Ordinance and in furtherance of those express standards and purposes of a site plan review pursuant to §15-9-03.B of the Unified Development Ordinance. NOW, THEREFORE, BE IT RESOLVED, by the Plan Commission of the City of Franklin, Wisconsin, that the Site Plan for the development of a single-story medical office building, as depicted upon the plans dated November 9 , 2026, attached hereto and incorporated herein, is hereby approved, subject to the following terms and conditions: 1. The property subject to the Site Plan shall be developed in substantial compliance with, and operated and maintained pursuant to the Site Plan for the SixSibs Capital Development dated November 9, 2026. 2. SixSibs Capital Development, successors and assigns, and any developer of the project, shall pay to the City of Franklin the amount of all development compliance, inspection and review fees incurred by the City of Franklin, including fees of consults to the City of Franklin, for the SixSibs Capital Development project, within 30 days of invoice for same. Any violation of this provision shall be a violation of the Unified Development Ordinance, and subject to §15-9-14 thereof and §1-19 of the Municipal Code, the general penalties and remedies provisions, as amended from time to time. 3. The approval granted hereunder is conditional upon the SixSibs Capital Development project for the property located at 10651 S Hickory St., (TKN 950 9002 000) : (i) being in compliance with all applicable governmental laws, statutes, rules, codes, orders and ordinances; and (ii) obtaining all other governmental approvals, permits, SIXSIBS CAPITAL DEVELOPMENT – SITE PLAN RESOLUTION NO. 2026-____ Page 2 licenses and the like, required for and applicable to the project to be developed and as presented for this approval. 4. That the SixSibs Capital Development Site Plan shall be developed and constructed pursuant to such Site Plan within two years from the date of adoption of this Resolution, or this Resolution and all rights and approvals granted hereunder shall be null and void, without any further action by the City of Franklin. 5. Site Plan approval will be conditioned on approval of a Variance of Design Standards by the Board of Zoning and Building Appeals. 6. Plan Commission waives the requirement of Planned Development District No. 39 (Mixed Use Business Park) Design Standards for: a. Large parking areas shall include walkways to allow safe pedestrian access to the building entrance and to connect the site to adjacent streets and properties (Section 15-3.0444B.D.2.c.ii.) b. All parking, loading, and unloading areas shall be screened from adjacent streets and sites utilizing landscaping, berms, and/or decorative fences (Section 15-3.0444B.D.1.a.vi.). Plan Commission waives this requirement for areas limited by WE Energies easement requirements on the west and south property line. Introduced at a regular meeting of the Plan Commission of the City of Franklin this _______ day of ____________________, 2026. Passed and adopted at a regular meeting of the Plan Commission of the City of Franklin this _______ day of ____________________, 2026. APPROVED: ATTEST: _________________________________ John R. Nelson, Mayor ___________________________________ Shirley J. Roberts, City Clerk AYES ______ NOES ______ ABSENT ______ HIC KO RY ST HIC KOR Y S T ELM RD HICKOR Y ST ELM RD City of Franklin Property Viewer 10651 S HICKORY ST Taxkey: 950 9002 000 City of Franklin, WI, City of Franklin, WI & Milwaukee County Land Information Office, SE Wisc Reg Planning Comm, Vantor Parcel Road Right-of-Way 11/11/2026, 12:57:55 PM 0 560 1,120280 ft 0 170 34085 m 1:4,162 Page | 1 FRANKLIN CORPORATE PARK PHASE 2 – FRANKLIN, WI PROJECT SUMMARY: The project development will be located in the Business Park district situated along South Hickory Street. Franklin Industrial II, LLC (identified as SixSibs Capital in these documents) will be developing two (2) Class A speculative industrial buildings in which tenants have not yet been identified. The proposed development will be a Class A industrial development that reflects best in class design standards for the asset class. Each building will be approximately 128,000 square feet. The buildings will be constructed with load bearing precast concrete painted wall panels and interior steel columns and roof framing. The proposed design includes two primary corner entrances and two secondary entry features each with their own storefront and canopies. Additional windows and clerestory windows are provided. The car traffic has been separated from truck traffic for safety purposes. Car parking is located on the front face of each building, to the south of building A and to the north of building B with both accessed from South Hickory Street. Truck loading and maneuvering is located between buildings in a shared truck court with access from South Hickory Street to the east. Two accessible routes will connect the building entrances to South Hickory Street for pedestrian and bike access. A stormwater detention pond will be located northwest of the buildings for onsite stormwater management and to provide visual amenities. The estimated project schedule is to break ground on the buildings in the second quarter of 2027 for completion in the fourth quarter of 2027. M I L W A U K E E R E G I O N A L O F F I C E : 2 0 7 2 5 W A T E R T O W N R O A D | S U I T E 1 0 0 | B R O O K F I E L D , W I 5 3 1 8 6 P : 2 6 2 . 7 5 4 . 8 8 8 8 | F : 2 6 2 . 7 5 4 . 8 8 5 0 | W W W . P I N N A C L E - E N G R . C O M M I L W A U K E E | C H I C A G O : N A T I O N W I D E PINNACLE ENGINEERING GROUP Plan | Design | Deliver w w w . p i n n a c l e - e n g r . c o m 11/9/2026 City of Franklin - Department of City Development Principal Planner Ms. Marion Ecks 9229 West Loomis Road Franklin, WI 53132 Re: SixSibs Somers Business Park (Groh Property) – Village Submittal Village of Somers, Kenosha County, Wisconsin PEG Job No. 2360.00-WI Dear Ms. Ecks, This letter is in response to the outstanding SWMP and civil engineering plan comments in your review letter dated 8/13/2026. General 1. Engineering will conduct a separate review of stormwater management and other items. Proposed site plans must match. Please contact them directly with questions 414-425-7510  We have been in contact with James Schaser and are co ordinating the engineering review. 2. T his property received approval of a Special Use to allow for overnight truck parking (RES 2021-7722) The lot was subsequently divided, but the legal description of that approval includes this property.  Noted. 3. This property received approval of a Natural Resource Special Exception in 2020 for impacts to w etland and woodlands. Compensation areas exist on the property and are protected by a conservation easement along with remaining natural resources.  Noted. Si te Plan The proposed development is being reviewed against PDL No. 39 zoning standards, which include design standards, and the Unified Development Ordinance. The size of the buildings and features of the design require Plan Commission approval.  Noted. General 1. S ignage requires separate permitting. Contact staff for information about sign permits.  Noted. 2. R eview comments are for buildings A and B. Future development will require a Site Plan Amendment with full design.  Noted. SIXSIBS FRANKLIN| COMMENT REVIEW RESPONSE 3. Site plan materials must depict the conservation easement on this property (Doc No. 11372007). No work or development is permitted with the easement boundary.  Noted. 4. A pplication complies with the requirements of the PDL No. 39 district zoning; setbacks and building height are met.  Noted. 5. Please provide information about dumpsters or other waste management facilities on site. Note that an y dumpster area must be screened. If none are proposed at this time, they will require a Minor Site Plan Amendment in future.  Dumpsters will be located inside of the building and will be brought out to haul away. In the case of a dumpster being located on the exterior, it will be screened. 6. Ground-/wall-mounted mechanical units that are visible from any public right-of-way or adjacent r esidential property shall be screened from public view.  Noted. Any ground/wall mounted mechanical units that are visible from any public right-of- way or adjacent residential property shall be screened from public view. 7. Please indicate vision clearance areas along S. Hickory on the site plan (§ 15-5-12). S. Hickory is a c ollector street.  Vision clearance areas have been added to the site en trances. Business Park Area Design Standards. (S ec. 15-3.0444B.D.) PDL 39 includes additional design requirements for all development. The applicant may request waivers of design standards from Plan Commission. 8. Large [passenger] parking areas shall include walkways to allow safe pedestrian access to the building entrance and to connect the site to adjacent streets and properties.  As discussed in a meeting with Marion Ecks on 11/4/2 6 , we are requesting a waiver to this requirement. 9. Each development which contains a building over forty-thousand (40,000) square feet in area shall p rovide extensive building foundation landscaping for all building frontages facing public streets.  Additional foundation plantings have been added for a reas facing the public street. 10. Trash, service, and mechanical areas shall be entirely screened from view and located on the side or r ear of properties.  Noted. 11. Roof mounted equipment shall be so located and/or screened to minimize visibility from adjacent s treets and sites.  Noted. 12. Staff recommends that the applicant request waivers of the 10’ foundation buffer landscape r equirement and material standards.  We will be requesting a waiver to this requirement. Parking 15-5-01 13 . The quantity of parking provided complies with the requirements of the UDO – 1 space per 1,000 square feet of building area. 7 ADA compliant parking spaces are required; design provides 8.  Noted. SIXSIBS FRANKLIN| COMMENT REVIEW RESPONSE 14. Please include information about pedestrian circulation in passenger parking areas. Pedestrian circulation must: • Be marked.  As discussed in a meeting with Marion Ecks on 11/4/26 , we are requesting a waiver to this requirement. • Connect building entrances on adjacent buildings on site to each other.  E ach proposed building has a walk along the entire fr ont side which connects to the multi-use path along South Hickory Street thereby providing connectivity between the building entrances. The truck dock sides of these buildings are also connected. The meeting with Marion on 11/5/26 confirmed that this is acceptable. • The on-site pedestrian circulation system shall provide at least one (1) connection to all ad jacent properties along a shared street frontage. Connections must provide access to existing walkways on adjacent properties, or to the likely future location of walkways on those properties. You may request a waiver of the requirement if you can demonstrate that this is impracticable.  Each proposed building has a walk along the entire fr ont side which connects to the multi-use path along South Hickory Street thereby providing connectivity between the building entrances. The meeting with Marion on 11/5/26 confirmed that this is acceptable. 15 . Bicycle parking is required – a minimum of five (5) percent of the off-street vehicle parking spaces provided, up to ten (10) required bicycle parking spaces. This must be located within 50’ of a building’s main entrance (§ 15-5-01E4).  Five bicycle stalls have been added to each building site. 16. Cross access for vehicles and pedestrians with adjoining lots is required. You may request a waiver o f the requirement if you can demonstrate that this is impracticable (§15-5-01.C)  Each proposed building is connected via drive aisle a long the west side of the site and each building also has a walk along the entire front side which connects to the multi-use path along South Hickory Street thereby providing connectivity between the building entrances. The truck dock sides of these buildings are also connected. The meeting with Marion on 11/5/26 confirmed that this is acceptable. 17 . Are any electric charging stations proposed?  No electric charging stations are being proposed. 18. Please indicate snow storage areas on plans. Landscaped and conservation areas cannot be used for s now storage. A minimum site area representing ten (10) percent of the total required off-street parking or loading area, inclusive of access drives, shall be provided as the snow storage area. See § 15-5-01.D for details.  These areas have been accounted for and are called ou t on Sheet L-1. SIXSIBS FRANKLIN| COMMENT REVIEW RESPONSE Landscaping 15-5-03, 04, 05 & 06 19. A bufferyard and buffering plantings are required in rear of the development (eastern property line) (§15-5-03.C, See §15-5-04.C for details)  Variance requested due to the existence of overhead u tility easements which do not allow for the installation of trees. In addition, the adjacent property line is heavily vegetated except where prohibited due to the overhead utility easement. 20. The landscape plan does not provide adequate plant quantities required by Table 15-5-04(A): S tandard Plant Units --- 1/10 parking spaces. A minimum of 22 plants in each category is required.  Additional landscape material has been added. 21. All areas not covered by buildings or paving should be covered with landscaping. The use of c onventional sod or turf grass as ground cover should be limited to those areas planned for active or passive recreation use, or other areas where substantial use of the area is anticipated. Low-growing ground cover such as Barren Strawberry (Waldesteinia) is preferred to grass.  Turf areas have been modified to provide a no mow fes cue blend in areas around the periphery of the site. 22. Irrigation is required.  N ote has been added to the plans noting that an irrig ation system is required and shall be provided. 23. Landscape plans should depict existing natural resource mitigation areas.  N o mitigation areas are currently proposed. 24. Note that species listed in Wis. Adm. Code Ch. NR 40 invasive species plant list shall not be used in an y landscape areas.  Understood. Lighting 15-5-11 25 . What is the height of the pole mounted light? Maximum permitted height is 25’.  Height of pole mounted lights varied from 23’ to 30’ in the original plan. Site lighting plan has been updated so no pole mounted light exceeds 25’. 26. Lighting color temperature must be between four thousand (4,000) and five thousand (5,000) d egrees Kelvin.  Lighting color temperature for lights will be 4,000 d egrees Kelvin. Architecture 15-5-10 27 . Please provide tables detailing material quantity for each façade (see example attached). You may refer to Table 15-5-10(B) for requirements.  Tables detailing material quantity for each façade in the format requested is attached. 28. The width of any continuous flat roofline should not extend more than one hundred (100) feet w ithout modulation. For flat roofs the minimum vertical dimension of roofline modulation is the greater of two (2) feet or ten (10) percent of the wall height.  An application for variance is being submitted for th is item. SIXSIBS FRANKLIN| COMMENT REVIEW RESPONSE 29. Glazing is required on the S. Hickory facades. The minimum required percentage of square footage in the transparency zone that must have a glazing treatment is 30%. See §15-5-10.E for details.  An application for variance is being submitted for th is item. Natural Resources – Article 7 30 . Please provide a complete Natural Resource Protection Plan (NRPP) with information required by §15- 7-03. Supplemental guidance for this is attached. Please note this guidance document is a draft; the NRPP must comply with the requirements of Article 7. The NRPP must include SEWRPC Environmental Corridor on the lot. Maps of this are available from https://www.sewrpc.org/Info-and-Data/Environmental-Co rridors  NRPP has been provided documenting the locations of t he various natural features along with the conservation easement. 2. Site plan materials must depict the conservation easement on this property (Doc No. 11372007). The e asement prohibits work or development within the easement boundary. If grading or other impacts are proposed, please schedule a meeting with staff to go over the scope and options. Impacts within the easement may require a Natural Resource Special Exception.  Conservation easement is being shown and no impacts a re being proposed within the conservation easement. Fire Department General Comments 1. Follow all relevant WI DSPS and IBC code requirements for fire protection systems for given occupancy, use, and construction types.  Noted. 2. Fire Extinguisher placement as per NFPA 10.  N oted. 3. F ire Department Connection (FDC), and hydrant placement and density must be acceptable to AHJ.  Noted. 4. A t no time may any Hazardous, Combustible, or Flammable Materials exceed allowable quantities.  Noted. 5. M aster Key set required for placement in Knox Box.  Noted. 6. P ermitting and submittal instructions for fire protection system review and inspection can be found at: https://www.franklinwi.gov/Departments/Fire.htm  Noted. SIXSIBS FRANKLIN| COMMENT REVIEW RESPONSE Engineering Department General Comments The Engineering Department has no issues with the proposed site plan. However, a separate Engineering Department review will need to be done prior to construction.  We have been in contact with James Schaser and are co ordinating the engineering review. If you have any questions on the information contained within, please do not hesitate to contact me at 262-754-8888 or via email at todd.mueller@pinnacle-engr.com. Thank you for your time in this matter. Best Regards, Pinnacle Engineering Group Todd G. Mueller, P.E. Associate Project Manager SILT FENCE E E E SOUTH LINE OF THE NW 1/4 SEC. 36, T5N, R21E S88°36'18"W 2631.37' OWNER: FRANKLIN INDUSTRIAL I LLC TAX KEY #9509001000 725 724 721 720 719 718 717 716 715 714 713 712 710 705 705 705 705 705 704 703 702 701 700 699 714 713 710 708 707 705 715 715 715 715 715 710 720 715 715715 TREELINE TREELINE TREELINE S S S S S S D D S DD 714 715 715715 715 715 717 717 714 718 718 717 716 715 714 715 717 716 718 721 D 697 699 698 703 700 705 707 710 713 714713 708 710 712 715 713 ((R) S88°36'13"W CSM 9260) EAST LINE OF THE NW 1/4 SEC. 36, T5N, R21E ((R) S88°36'18"W 701.28' CSM 9530) ((R) S00°22'00"W 1,505.42' CSM 9530) ((R) N89°38'00"E 701.17' CSM 9530) ((R) N00°22'00"W 1,518.01' CSM 9530) POND 712 709 708 707 711 708 708 706 707 709 708707706 704705 702703 701 711 710709708 707706705705 716717718 714 712 713 711711 712 713 713 714 714 713 713 712 714 712713 712 713 715 714 714713 713 717 716 717 715 706707 708 708 707708 706 704 703 702 701 716 704 703 702701 699 714713 716 717 713 714 715 715 714 715 717 717 716 717 716 716 716 716 716 716 718719 721 717 718719 720721722 718719720718719718 718 719 716 717 718 719 717 716715 717 716 715 714 713 714 715 716 717717 716 715 714 713 713 713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 715 716 717 713 714 715 717 716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717 714 713 715 714 713 712 711 711712 713 716715714713712 716 717 717 716 715 714 713712 716 717 717716715 714713712 716 716 716 717716715 716 717 717 717 717 717 717 717 717 717 712 714 713 716 717716 717 717717 704705706707708709710711712713714715 717716 716 723 721 722 717 716715 715 716 717 715 716 717 717716715 711 705706707 708 714710706 714710706 711 710 709 712 713 714 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION FUTURE BUILDING C D.I.DD.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D SOUTH HICKORY STREET EXISTING WETLAND PINNACLE ENGINEERING GROUP 20725 WATERTOWN ROAD | SUITE 100 | BROOKFIELD, WI 53186 | WWW.PINNACLE-ENGR.COM | PLAN | DESIGN | DELIVER PEGJOB# Z:\PROJECTS\2025\6920.00-WI\CAD\EXHIBITS\6920.00-WI FRANKLIN BUISNESS PARK NRPP_.DWG 11/9/2026 12:47 PM 6920.00-WI SIXSIBS FRANKLIN WI NATURAL RESOURCE PROTECTION PLAN 11/09/2026 30' WETLAND BUFFER SYMBOL DESCRIPTION QTY WETLAND BUFFER 39,806 sf FEDERAL WETLAND 51,683 sf ENVIRONMENTAL CORRIDOR 46,357 sf REFERENCE NOTES KEY 1" = 80'0 160' GRAPHICAL SCALE (FEET) NORTH NRPP Compensation / Restoration RatioUnitImpact by Natural Resource Type SEWRPC Primary Environmental Corridor and Buffers SEWRPC Secondary Environmental Corridor and Buffers SEWRPC Isolated Natural Resource and Buffer Surface Water or Wetland Buffers (1) applicable to surface waters, shoreland wetlands, and federal jurisdiction wetlands Woodland 1.5 1.5 compensation may include restoration or enhancement of a new or degraded buffer, or compensation permitted in § 15-7-02(E) and NR Guidance 0.75SF Type of Approval Required for Impacts Trees >8" outside woodland Degraded Wetland and Non-federal Jurisdiction Wetlands Federal Jurisdiction Wetlands and Shoreland Wetlands (1) SF SF SF SF SF SF Surface Waters (1) SF Caliper DBH removed 1.5 1.5 Surface Water or Wetland Buffers applicable to non-federal jurisdiction or degraded wetlands, or buffers that are poorly vegetated/degraded or with impervious areas present (3) 1.0 compensation may include restoration or enhancement of a new or degraded buffer, or compensation permitted in § 15-7-02(E) and NR Guidance SF 2" caliper per 8" removed 1.5 compensation may utilize approaches permitted in § 15-7-02(E) and NR Guidance Minimum 1.5 utilizing Guidelines for Wetland Compensatory Mitigation in Wisconsin 1.0 requires applicable state or federal permits Special Exception Special Exception Special Exception Special Exception Site Plan or PUD Site Plan or PUD Site Plan or PUD Site Plan or PUD Special Exception Special Exception Total Impact N/A N/A N/A N/A Total Area 46,357 (1.06 AC) N/A N/A 51,683 SF 39,806 SF (0.91 AC) N/A N/A N/A · WETLANDS SHOWN PER CSM 9530 N/A N/A N/A N/A N/A N/A N/A N/A CONSERVATION EASEMENT CONSERVATION EASEMENT ENVIRONMENTAL CORRIDOR (1.19 AC) BM 1 BM 2 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI COVER SHEET.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM COVER SHEET 1CITY COMMENTS11/09/26C-1 N.T.S. COVER SHEET FRANKLIN SIX SIBS C-1COVER SHEET C-2GENERAL NOTES C-3 EXISTING CONDITIONS & DEMOLITION PLAN OVERVIEW C-4 - C-5 EXISTING CONDITIONS & DEMOLITION PLAN C-6 SITE DIMENSIONAL & PAVING PLAN OVERVIEW C-7 - C-8 SITE DIMENSIONAL & PAVING PLAN C-9 GRADING PLAN OVERVIEW C-10 - C-12 GRADING PLAN C-13 EROSION CONTROL PLAN OVERVIEW C-14 - C-16 EROSION CONTROL PLAN C-17 UTILITY PLAN OVERVIEW C-18 - C-19 UTILITY PLAN C-20 - C-21 CONSTRUCTION DETAILS L-1TREE OVERVIEW L-2 TREE ENLARGEMENT L-3 SHRUB OVERVIEW L-4 - L-5 SHRUB ENLARGEMENT L-6 LANDSCAPE GENERAL NOTES & DETAILS LEGEND EASEMENT LINE SOIL BORING TOPSOIL PROBE REVERSE PITCH CURB & GUTTER DEPRESSED CURB NORMAL WATER LEVEL (NWL) HIGH WATER LEVEL (HWL) CLEANOUT FLOODPLAIN FLOODWAY WETLANDS FIRE HYDRANT LIGHTING SANITARY SEWER STORM SEWER WATER MAIN GRANULAR TRENCH BACKFILL BUFFALO BOX FORCE MAIN ELECTRICAL TRANSFORMER CONTOUR SPOT ELEVATION DIRECTION OF SURFACE FLOW OVERFLOW RELIEF ROUTING TREE WITH TRUNK SIZE POWER POLE STREET SIGN DITCH OR SWALE GAS MAIN TELEPHONE LINE FENCE LINE, WIRE CONCRETE SIDEWALK CURB AND GUTTER VALVE BOX ELECTRICAL CABLE OR PEDESTAL SANITARY MANHOLE STORM MANHOLE CATCH BASIN INLET PRECAST FLARED END SECTION VALVE VAULT CONCRETE HEADWALL EXISTINGPROPOSED FENCE LINE, CHAIN LINK OR IRON FENCE LINE, WOOD OR PLASTIC WW POWER POLE WITH LIGHT GUY WIRE UTILITY CROSSING FENCE LINE, TEMPORARY SILT DIVERSION SWALE PROPERTY LINE ABBREVIATIONS C & G EP FG FF FL FP FW HWL NSI ROW TB TC TF TS TW CURB AND GUTTER EDGE OF PAVEMENT FINISHED GRADE FINISHED FLOOR FLOW LINE FLOODPLAIN FLOODWAY HIGH WATER LEVEL NATIVE SOIL INTERFACE RIGHT-OF-WAY TOP OF BANK TOP OF CURB TOP OF FOUNDATION TOP OF SIDEWALK TOP OF WALK BL CL FR INV PC PT PVI C D L R T ST MH CB WM SAN BASE LINE CENTERLINE FRAME INVERT POINT OF CURVATURE POINT OF TANGENCY POINT OF VERTICAL INTERSECTION LONG CHORD OF CURVE DEGREE OF CURVE LENGTH OF CURVE RADIUS TANGENCY OF CURVE INTERSECTION ANGLE STORM SEWER MANHOLE CATCH BASIN WATER MAIN SANITARY SEWER NWL NORMAL WATER LEVEL BENCHMARKS NORTH NOTE VERTICAL DATUM: NORTH AMERICAN VERTICAL DATUM OF 1988(12), (NAVD88) REFERENCE BENCHMARK #1 CONCRETE MONUMENT WITH BRASS CAP AT THE NORTHEAST CORNER OF THE NORTHWEST 1/4 SECTION 36, TOWN 5 NORTH, RANGE 21 EAST ELEV = 721.72 SITE BENCHMARK #2 NW FLANGE BOLT ON HYDRANT ELEV = 719.31 1. THE INTENTION OF THE PLANS AND SPECIFICATIONS IS TO SET FORTH PERFORMANCE AND CONSTRUCTION MATERIAL STANDARDS FOR THE PROPER EXECUTION OF WORK. ALL WORKS CONTAINED WITHIN THE PLANS AND SPECIFICATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ALL REQUIREMENTS FROM LOCAL, STATE, FEDERAL OR OTHER GOVERNING AGENCY'S LAWS, REGULATIONS, JURISDICTIONAL ORDINANCES/CODES/RULES/ETC., AND THE OWNER'S DIRECTION. 2. A GEOTECHNICAL REPORT FOR THIS SITE HAS BEEN PREPARED BY INTERTEK PSI DATED DECEMBER 8, 2020. THE DATA ON SUB-SURFACE SOIL CONDITIONS IS NOT INTENDED AS A REPRESENTATION OR WARRANTY OF THE CONTINUITY OF SUCH CONDITIONS BETWEEN BORINGS OR INDICATED SAMPLING LOCATIONS. IT SHALL BE EXPRESSLY UNDERSTOOD THAT OWNER WILL NOT BE RESPONSIBLE FOR ANY INTERPRETATIONS OR CONCLUSIONS DRAWN THERE FROM BY THE CONTRACTOR. DATA IS MADE AVAILABLE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING ANY ADDITIONAL SOILS INVESTIGATIONS THEY FEEL IS NECESSARY FOR THE PROPER EVALUATION OF THE SITE FOR PURPOSES OF PLANNING, BIDDING, OR CONSTRUCTING THE PROJECT AT NO ADDITIONAL COST TO THE OWNER. 3. THE CONTRACTOR IS RESPONSIBLE TO REVIEW AND UNDERSTAND ALL COMPONENTS OF THE PLANS AND SPECIFICATIONS, INCLUDING FIELD VERIFYING SOIL CONDITIONS, PRIOR TO SUBMISSION OF A BID PROPOSAL. 4. THE CONTRACTOR SHALL PROMPTLY REPORT ANY ERRORS OR AMBIGUITIES LEARNED AS PART OF THEIR REVIEW OF PLANS, SPECIFICATIONS, REPORTS AND FIELD INVESTIGATIONS. 5. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE COMPUTATION OF QUANTITIES AND WORK REQUIRED TO COMPLETE THIS PROJECT. THE CONTRACTOR'S BID SHALL BE BASED ON ITS OWN COMPUTATIONS AND IN NO SUCH INSTANCE RELY ON THE ENGINEER'S ESTIMATE. 6. QUESTIONS/CLARIFICATIONS WILL BE INTERPRETED BY ENGINEER/OWNER PRIOR TO THE AWARD OF CONTRACT. ENGINEER/OWNER WILL SUBMIT OFFICIAL RESPONSES IN WRITING. INTERPRETATIONS PRESENTED IN OFFICIAL RESPONSES SHALL BE BINDING ON ALL PARTIES ASSOCIATED WITH THE CONTRACT. IN NO WAY SHALL WORD-OF-MOUTH DIALOG CONSTITUTE AN OFFICIAL RESPONSE. 7. PRIOR TO START OF WORK, CONTRACTOR SHALL BE COMPLETELY FAMILIAR WITH ALL CONDITIONS OF THE SITE, AND SHALL ACCOUNT FOR CONDITIONS THAT AFFECT, OR MAY AFFECT CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, LIMITATIONS OF WORK ACCESS, SPACE LIMITATIONS, OVERHEAD OBSTRUCTIONS, TRAFFIC PATTERNS, LOCAL REQUIREMENTS, ADJACENT ACTIVITIES, ETC. FAILURE TO CONSIDER SITE CONDITIONS SHALL NOT BE CAUSE FOR CLAIM OF JOB EXTRAS. 8. COMMENCEMENT OF CONSTRUCTION SHALL EXPLICITLY CONFIRM THAT THE CONTRACTOR HAS REVIEWED THE PLANS AND SPECIFICATIONS IN ENTIRETY AND CERTIFIES THAT THEIR SUBMITTED BID PROPOSAL CONTAINS PROVISIONS TO COMPLETE THE PROJECT, WITH THE EXCEPTION OF UNFORESEEN FIELD CONDITIONS; ALL APPLICABLE PERMITS HAVE BEEN OBTAINED; AND CONTRACTOR UNDERSTANDS ALL OF THE REQUIREMENTS OF THE PROJECT. 9. SHOULD ANY DISCREPANCIES OR CONFLICTS IN THE PLANS OR SPECIFICATIONS BE DISCOVERED AFTER THE AWARD OF CONTRACT, ENGINEER SHALL BE NOTIFIED IN WRITING IMMEDIATELY AND CONSTRUCTION OF ITEMS AFFECTED BY THE DISCREPANCIES/CONFLICTS SHALL NOT COMMENCE, OR CONTINUE, UNTIL A WRITTEN RESPONSE FROM ENGINEER/OWNER IS DISTRIBUTED. IN THE EVENT OF A CONFLICT BETWEEN REFERENCED CODES, STANDARDS, SPECIFICATIONS AND PLANS, THE ONE ESTABLISHING THE MOST STRINGENT REQUIREMENTS SHALL BE FOLLOWED. 10. THE CONTRACTOR SHALL, AT ITS OWN EXPENSE, OBTAIN ALL NECESSARY PERMITS AND LICENSES TO COMPLETE THE PROJECT. OBTAINING PERMITS, OR DELAYS, IS NOT CAUSE FOR DELAY OF THE CONTRACT OR SCHEDULE. CONTRACTOR SHALL COMPLY WITH ALL PERMIT REQUIREMENTS. 11. THE CONTRACTOR SHALL NOTIFY ALL INTERESTED GOVERNING AGENCIES, UTILITY COMPANIES AFFECTED BY THIS CONSTRUCTION PROJECT, AND DIGGER'S HOTLINE IN ADVANCE OF CONSTRUCTION TO COMPLY WITH ALL JURISDICTIONAL ORDINANCES/CODES/RULES/ETC., PERMIT STIPULATIONS, AND OTHER APPLICABLE STANDARDS. 12. SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE TO INITIATE, INSTITUTE, ENFORCE, MAINTAIN, AND SUPERVISE ALL SAFETY PRECAUTIONS AND JOB SITE SAFETY PROGRAMS IN CONNECTION WITH THE WORK. 13. CONTRACTOR SHALL KEEP THE JOBSITE CLEAN AND ORDERLY AT ALL TIMES. ALL LOCATIONS OF THE SITE SHALL BE KEPT IN A WORKING MANNER SUCH THAT DEBRIS IS REMOVED CONTINUOUSLY AND ALL RESPECTIVE CONTRACTORS OPERATE UNDER GENERAL “GOOD HOUSEKEEPING.” 14. THE CONTRACTOR SHALL INDEMNIFY THE CITY ENGINEER, CITY BUILDING INSPECTOR, OWNER, ENGINEER, AND THEIR AGENTS FROM ALL LIABILITY INVOLVED WITH THE CONSTRUCTION, INSTALLATION, AND TESTING OF THE WORK ON THIS PROJECT. 15. PRIOR TO CONSTRUCTION, A PRECONSTRUCTION MEETING MUST BE HELD AT THE CITY OFFICES. THE PRECONSTRUCTION MEETING SHALL BE SCHEDULED AND MODERATED BY THE DESIGN ENGINEER OF RECORD. GENERAL NOTES PINNACLE ENGINEERING GROUP, LLC ENGINEER'S LIMITATION PINNACLE ENGINEERING GROUP, LLC AND THEIR CONSULTANTS DO NOT WARRANT OR GUARANTEE THE ACCURACY AND COMPLETENESS OF THE DELIVERABLES HEREIN BEYOND A REASONABLE DILIGENCE. IF ANY MISTAKES, OMISSIONS, OR DISCREPANCIES ARE FOUND TO EXIST WITHIN THE DELIVERABLES, THE ENGINEER SHALL BE PROMPTLY NOTIFIED PRIOR TO BID SO THAT HE MAY HAVE THE OPPORTUNITY TO TAKE WHATEVER STEPS NECESSARY TO RESOLVE THEM. FAILURE TO PROMPTLY NOTIFY THE ENGINEER OF SUCH CONDITIONS SHALL ABSOLVE THE ENGINEER FROM ANY RESPONSIBILITY FOR THE CONSEQUENCES OF SUCH FAILURE. ACTIONS TAKEN WITHOUT THE KNOWLEDGE AND CONSENT TO THE ENGINEER, OR IN CONTRADICTION TO THE ENGINEER'S DELIVERABLES OR RECOMMENDATIONS, SHALL BECOME THE RESPONSIBILITY NOT OF THE ENGINEER BUT OF THE PARTIES RESPONSIBLE FOR TAKING SUCH ACTION. FURTHERMORE, PINNACLE ENGINEERING GROUP, LLC IS NOT RESPONSIBLE FOR CONSTRUCTION SAFETY OR THE MEANS AND METHODS OF CONSTRUCTION. EXPIRATION DATE: JULY 31, 2028 PROJECT TEAM CONTACTS CIVIL ENGINEER: SCOTT MAIER, P.E., PINNACLE ENGINEERING GROUP 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 smaier@pinnacle-engr.com TODD MUELLER, P.E., PINNACLE ENGINEERING GROUP 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 todd.mueller@pinnacle-engr.com SURVEYOR: JOHN KONOPACKI, P.L.S. PINNACLE ENGINEERING GROUP 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 john.konopacki@pinnacle-engr.com ARCHITECT: ERIC ORTEGA PARTNERS IN DESIGN 2610 LAKE COOK ROAD, SUITE 280 RIVERWOODS, IL 60015 (847) 940-0300 erico@pidarchitects.com APPLICANT: PATRICK NOONAN, RPA, CPM SIX SIBS CAPITAL 195 S RITE HITE WAY MILWAUKEE, WI 53203 (414) 336-2226 pnoonan@sixsibscapital.com REQUIRED SUBMITTALS FOR APPROVAL 1. ASPHALT PAVEMENTS 2. CONCRETE PAVEMENTS (EXTERIOR) 3. STONE BASE COURSE 4. TRENCH BACKFILL 5. PIPE BEDDING 6. TIE BARS 7. DOWEL BARS 8. DOWEL BAR BASKETS REQUIRED SUBMITTALS FOR RECORDS 1. WATER MAIN PIPE FITTINGS 2. SANITARY SEWER 3. STORM SEWER 4. SUBGRADE STABILIZATION (IF APPLICABLE) LOCATION MAP SCALE 1" = 500' NORTH PROJECT LOCATION W ELM RD ONSITE CIVIL ENGINEERING INFRASTRUCTURE PLANS FOR FRANKLIN SIX SIBS FRANKLIN, WI PLANS PREPARED FOR SIX SIBS CAPITAL 195 S RITE HITE WAY MILWAUKEE, WI S HICKORY ST W OAKWOOD RD INDEX OF SHEETS DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI GENERAL NOTES.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM GENERAL NOTES 1CITY COMMENTS11/09/26C-2 N.T.S. GENERAL NOTES FRANKLIN SIX SIBS SITE DIMENSIONAL & PAVING NOTES 1. ALL PAVING SHALL CONFORM TO STATE OF WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY & STRUCTURE CONSTRUCTION (STANDARD SPECIFICATIONS), LATEST EDITION AND APPLICABLE COUNTY AND MUNICIPAL ORDINANCES, AND SPECIFICATIONS (LOCAL SPECIFICATIONS) CONTAINED WITHIN THIS PLAN SET. THESE STANDARDS ARE TO BE USED WHEREVER WISDOT OR STANDARD OR LOCAL SPECIFICATIONS APPEARS ON THE PLANS. 2. ALL DIMENSIONS ARE EDGE OF PAVEMENT, FACE OF CURB, SHOULDER, OR CENTER OF LANE LINE UNLESS NOTED OTHERWISE. 3. BUILDING DIMENSIONS AND ADJACENT PARKING AND UTILITY LAYOUT HAVE BEEN PREPARED BASED UPON ARCHITECTURAL INFORMATION CURRENT AT THE DATE OF THIS DRAWING. SUBSEQUENT ARCHITECTURAL CHANGES MAY EXIST. THEREFORE, CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS AND NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. IMPROVEMENTS ADJACENT TO BUILDING IF SHOWN SUCH AS TRUCK DOCK, RETAINING WALLS, SIDEWALKS, CURBING, FENCES, CANOPIES, RAMPS, HANDICAP ACCESS, PLANTERS, DUMPSTERS, AND TRANSFORMERS ETC. HAVE BEEN SHOWN FOR APPROXIMATE LOCATION ONLY. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS, SPECIFICATIONS, AND DETAILS. 5. REFER TO ELECTRICAL PLANS FOR LIGHTING LOCATIONS, SPECIFICATIONS, AND DETAILS. 6. ASPHALTIC CONCRETE PAVING SPECIFICATIONS: 6.1. CODES AND STANDARDS: THE PLACING, CONSTRUCTION AND COMPOSITION OF THE ASPHALTIC BINDER COURSE AND ASPHALTIC SURFACE COURSE SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS 450, 455, 460 AND 465 OF THE STATE OF WISCONSIN STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION, LATEST EDITION. HEREAFTER, THIS PUBLICATION WILL BE REFERRED TO AS THE STATE HIGHWAY SPECIFICATIONS. 6.2. APPLY TACK COAT IN ACCORDANCE WITH APPLICABLE SECTIONS OF THE STANDARD HIGHWAY SPECIFICATIONS. 6.3. WEATHER LIMITATIONS - APPLY TACK COATS WHEN AMBIENT TEMPERATURE IS ABOVE 45°F (10°C) AND WHEN TEMPERATURE HAS NOT BEEN BELOW 35°F (1°C) FOR 12 HOURS IMMEDIATELY PRIOR TO APPLICATION. DO NOT APPLY WHEN BASE IS WET OR CONTAINS EXCESS OF MOISTURE. CONSTRUCT ASPHALTIC CONCRETE SURFACE COURSE WHEN ATMOSPHERIC TEMPERATURE IS ABOVE 40°F (4°C) AND WHEN BASE IS DRY AND WHEN WEATHER IS NOT RAINY. BASE COURSE MAY BE PLACED WHEN AIR TEMPERATURE IS ABOVE 30°F (-1°C). FOR CONCRETE PAVEMENTS PLACEMENT IS NOT TO BE PERFORMED IF THE AMBIENT TEMPERATURE IN THE SHADE FALLS BELOW 35°F UNLESS WRITTEN PERMISSION IS OBTAINED FROM THE ENGINEER. IF FREEZING TEMPERATURES ARE FORECASTED WITHIN 24 HOURS OF A POUR, A PROTECTIVE COATING WILL NEED TO BE APPLIED IN ACCORDANCE WITH 415.3.13.2 OF THE STANDARD SPECIFICATIONS. 6.4. GRADE CONTROL: ESTABLISH AND MAINTAIN REQUIRED LINES AND ELEVATIONS FOR EACH COURSE DURING CONSTRUCTION. 6.5. CRUSHED AGGREGATE BASE COURSE: THE TOP LAYER OF BASE COURSE SHALL CONFORM TO APPLICABLE SECTIONS 301 AND 305 OF THE STATE HIGHWAY SPECIFICATIONS. 6.6. BINDER COURSE AGGREGATE: THE AGGREGATE FOR THE BINDER COURSE SHALL CONFORM TO APPLICABLE SECTIONS 460 AND 315 OF THE STATE HIGHWAY SPECIFICATIONS. 6.7. SURFACE COURSE AGGREGATE: THE AGGREGATE FOR THE SURFACE COURSE SHALL CONFORM TO SECTIONS 460 AND 465 OF THE STATE HIGHWAY SPECIFICATIONS. 6.8. ASPHALTIC MATERIALS: THE ASPHALTIC MATERIALS SHALL CONFORM TO SECTION 455 AND 460, STATE HIGHWAY SPECIFICATIONS. 9. CONCRETE PAVING SPECIFICATIONS: 9.1. CODES AND STANDARDS: THE PLACING, CONSTRUCTIONS AND COMPOSITION OF THE CONCRETE PAVEMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS 415 AND 416 OF THE STANDARD SPECIFICATIONS. 9.2. CRUSHED AGGREGATE BASE COURSE: THE BASE COURSE SHALL CONFORM TO SECTIONS 301 AND 305 OF THE STANDARD SPECIFICATIONS. CLEAN RECYCLED CRUSHED CONCRETE MAY BE USED IF APPROVED BY GEOTECH ENGINEER OF RECORD. 9.3. SURFACE PREPARATION: NOTIFY CONTRACTOR OF UNSATISFACTORY CONDITIONS DO NOT BEGIN PAVING WORK UNTIL DEFICIENT SUBBASE AREAS HAVE BEEN CORRECTED AND ARE READY TO RECEIVE PAVING. 10. PAVEMENT MARKING SPECIFICATIONS: 10.1. DO NOT PLACE MARKING OVER UNSOUND PAVEMENTS. IF THESE CONDITIONS EXIST, NOTIFY OWNER. STARTING INSTALLATION CONSTITUTES CONTRACTOR'S ACCEPTANCE THAT THE SURFACE AS SUITABLE FOR INSTALLATION. 10.2. PROVIDE CONTRACTOR GRADE STRIPING EPOXY FOR NEW ASPHALT OR COATED ASPHALT. APPLY MARKING EPOXY AT A RATE OF ONE (1) GALLON PER THREE TO FOUR HUNDRED (300-400) LINEAL FEET OF FOUR (4) INCH WIDE STRIPES OR TO MANUFACTURER'S SPECIFICATION, WHICHEVER IS GREATER. 10.3. PRIOR TO APPLYING STRIPING OR MARKING EPOXY PAINT, THOROUGHLY CLEAN EXISTING PAVEMENT SURFACES FREE OF DIRT, SAND, GRAVEL, OIL AND OTHER FOREIGN MATTER. CONTRACTOR RESPONSIBLE FOR INSPECTING EXISTING PAVEMENT SURFACES FOR CONDITIONS AND DEFECTS THAT WILL ADVERSELY AFFECT QUALITY OF WORK. 10.4. LAYOUT MARKINGS USING GUIDELINES, TEMPLATES AND FORMS. STENCILS AND TEMPLATES SHALL BE PROFESSIONALLY MADE TO INDUSTRY STANDARDS. "FREE HAND" PAINTING OF ARROWS, SYMBOLS, OR WORDING SHALL NOT BE ALLOWED. APPLY STRIPES STRAIGHT AND EVEN. 10.5. PROTECT ADJACENT CURBS, WALKS, FENCES, AND OTHER ITEMS FROM RECEIVING EPOXY PAINT. 10.6. BARRICADE MARKED AREAS DURING INSTALLATION AND UNTIL THE MARKING EPOXY PAINT IS DRIED AND READY FOR TRAFFIC. 11. TRAFFIC CONTROL SHALL BE PER M.U.T.C.D (LATEST EDITION) AND WISDOT SPECIFICATIONS, OR AS SHOWN ON THE PLAN. 12. ALL JOINTS BETWEEN EXISTING AND PROPOSED CONCRETE PAVEMENT AND CURB AND GUTTER SHALL BE JOINED WITH NO. 4 TIE BARS. ANY TIE BARS INSTALLED IN A DRILLED HOLE SHALL BE ANCHORED WITH AN EPOXY. 12. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). GRADING NOTES 1. CONTRACTOR SHALL COMPLY WITH ALL STATE, COUNTY, AND MUNICIPAL CONSTRUCTION STANDARDS/ORDINANCES. 2. GRADING ACTIVITIES SHALL BE CONDUCTED IN A MANNER TO ALLOW POSITIVE DRAINAGE ACROSS DISTURBED SOILS, WHICH MAY INCLUDE EXCAVATION OF TEMPORARY DITCHES TO PREVENT PONDING, AND IF NECESSARY, DEWATERING TO ALLEVIATE PONDING. CONTRACTOR SHALL PREVENT SURFACE WATER FROM ENTERING INTO EXCAVATIONS. IN NO WAY SHALL OWNER BE RESPONSIBLE FOR REMEDIATION OF UNSUITABLE SOILS CREATED/ORIGINATED AS A RESULT OF IMPROPER SITE GRADING OR SEQUENCING. CONTRACTOR SHALL SEQUENCE GRADING ACTIVITIES TO LIMIT EXPOSURE OF DISTURBED SOILS DUE TO WEATHER. 3. CONTRACTOR SHALL VERIFY ALL GRADES, ENSURE ALL AREAS DRAIN PROPERLY AND REPORT ANY DISCREPANCIES TO PINNACLE ENGINEERING GROUP PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITIES. 4. ALL EXISTING CONTOURS REPRESENT EXISTING SURFACE GRADES UNLESS OTHERWISE NOTED. ALL PROPOSED GRADES SHOWN ARE FINISH SURFACE GRADES UNLESS OTHERWISE NOTED. 5. SPOT ELEVATIONS REPRESENT THE GRADE ALONG THE CURB AND GUTTER FLANGELINE UNLESS OTHERWISE NOTED. 6. ALL EXCAVATIONS AND MATERIAL PLACEMENT SHALL BE COMPLETED TO DESIGN ELEVATIONS AS DEPICTED IN THE PLANS. 7. CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR THE COMPUTATION(S) OF ALL GRADING QUANTITIES. WHILE PEG ATTEMPTS TO PROVIDE AN EFFECTIVE APPROACH TO BALANCING EARTHWORK, GRADING DESIGN IS BASED ON MANY FACTORS, INCLUDING SAFETY, AESTHETICS, AND COMMON ENGINEERING STANDARD OF CARE, THEREFORE NO GUARANTEE CAN BE MADE FOR A BALANCED SITE. THE CONTRACTOR MAY SOLICIT APPROVAL FROM ENGINEER/OWNER TO ADJUST FINAL GRADES FROM DESIGN GRADES TO PROVIDE AN OVERALL SITE BALANCE AS A RESULT OF FIELD CONDITIONS. 8. THE CONTRACTOR IS RESPONSIBLE FOR MEETING MINIMUM COMPACTION STANDARDS. THE CONTRACTOR SHALL NOTIFY ENGINEER/OWNER IF PROPER COMPACTION CANNOT BE OBTAINED. THE PROJECT'S GEOTECHNICAL CONSULTANT SHALL DETERMINE WHICH IN-SITU SOILS ARE TO BE CONSIDERED UNSUITABLE SOILS. THE ENGINEER/OWNER AND GEOTECHNICAL TESTING CONSULTANT WILL DETERMINE IF REMEDIAL MEASURES WILL BE NECESSARY. 9. IN THE EVENT THAT ANY COMPACTION TEST(S) FAIL TO MEET SPECIFICATION REQUIREMENTS, THE CONTRACTOR SHALL PERFORM CORRECTIVE WORK AS NECESSARY TO BRING THE MATERIAL INTO COMPLIANCE AND RETEST THE FAILED AREA AT NO COST TO THE OWNER. 10. WITH THE AUTHORIZATION OF THE ENGINEER/OWNER, MATERIAL THAT IS TOO WET TO PERMIT PROPER COMPACTION MAY BE SPREAD ON FILL AREAS IN AN EFFORT TO DRY. CONTRACTOR SHALL CLEARLY FIELD MARK THE EXTERIOR LIMITS OF SPREAD MATERIAL WITH PAINTED LATH AND SUBMIT A PLAN TO THE ENGINEER/OWNER THAT IDENTIFIES THE LIMITS. UNDER NO CONDITION SHALL THE SPREAD MATERIAL DEPTH EXCEED THE MOST RESTRICTIVE OF: THE EFFECTIVE TREATMENT DEPTH OF MACHINERY THAT WILL BE USED TO TURNOVER THE SPREAD MATERIAL; OR THE MAXIMUM COMPACTION LIFT DEPTH. 11. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER/OWNER IF GROUNDWATER IS ENCOUNTERED DURING EXCAVATION. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ADEQUATE AND SAFE TEMPORARY SHORING, BRACING, RETENTION STRUCTURES, AND EXCAVATIONS. 12. THE SITE SHALL BE COMPLETED WITHIN 0.1-FT (+/-) OF THE PROPOSED GRADES AS INDICATED WITHIN THE PLANS PRIOR TO PLACEMENT OF TOPSOIL OR STONE. CONTRACTOR IS ENCOURAGED TO SEQUENCE CONSTRUCTION SUCH THAT THE SITE IS DIVIDED INTO SMALLER AREAS TO ALLOW STABILIZATION OF DISTURBED SOILS IMMEDIATELY UPON COMPLETION OF SAID AREAS. 13. WORK WITHIN ANY ROADWAY RIGHT-OF-WAY SHALL BE COORDINATED WITH THE APPROPRIATE MUNICIPAL OFFICIAL PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FEES. GRADING WITHIN RIGHT-OF-WAY IS SUBJECT TO APPROVAL BY SAID OFFICIALS. RESTORATION OF RIGHT-OF-WAY IS CONSIDERED INCIDENTAL AND SHALL BE INCLUDED IN THE COST OF GRADING. RESTORATION SHALL INCLUDE ALL ITEMS NECESSARY TO RESTORE RIGHT-OF-WAY IN-KIND INCLUDING LANDSCAPING. 14. LANDSCAPE AND TURF AREAS SHALL HAVE A MINIMUM OF 4-INCH TOPSOIL REPLACEMENT, UNLESS OTHERWISE SPECIFIED IN THE PLAN. 15. TOPSOIL BERMING SHALL ACHIEVE 90% STANDARD PROCTOR DENSITY AT (±)3% OPTIMUM MOISTURE CONTENT. 16. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). GENERAL UTILITY NOTES 1. ALL UTILITY WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN (LATEST EDITION AND ADDENDUM) AND ALL STATE AND LOCAL CODES AND SPECIFICATIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHICH SPECIFICATIONS AND CODES APPLY, AND TO COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE LOCAL AND STATE AUTHORITIES. 2. EXISTING UTILITIES ARE SHOWN FOR INFORMATIONAL PURPOSES ONLY AND ARE NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE TYPE, LOCATION, SIZE AND ELEVATION OF UNDERGROUND UTILITIES AS THEY DEEM NECESSARY FOR PROPOSED UTILITY CONNECTIONS AND/OR TO AVOID DAMAGE THERETO. CONTRACTOR SHALL CALL "DIGGER'S HOTLINE" PRIOR TO ANY CONSTRUCTION. 3. LENGTHS OF PROPOSED UTILITIES ARE TO CENTER OF STRUCTURES OR FITTINGS AND MAY VARY SLIGHTLY FROM PLAN. LENGTHS ARE SHOWN FOR CONTRACTOR CONVENIENCE ONLY. CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPUTATIONS OF MATERIALS REQUIRED TO COMPLETE WORK. LENGTHS SHALL BE FIELD VERIFIED DURING CONSTRUCTION. 4. CONTRACTOR SHALL ADJUST AND/OR RECONSTRUCT EXISTING UTILITY COVERS (SUCH AS MANHOLE COVERS, VALVE BOX COVERS, ETC.) TO MATCH FINISHED GRADES OF THE AREAS DISTURBED DURING CONSTRUCTION. 5. CONTRACTOR SHALL FIELD VERIFY LOCATIONS, ELEVATIONS, AND SIZES OF PROPOSED UTILITIES AND CHECK ALL UTILITY CROSSINGS FOR CONFLICTS PRIOR TO ATTEMPTING CONNECTIONS AND BEGINNING UTILITY CONSTRUCTION AND NOTIFY THE OWNER OF ANY DISCREPANCIES OR CONFLICTS. 6. ALL NEW ON-SITE SANITARY, STORM AND WATER UTILITIES SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER, EXCEPT FOR THOSE UTILITIES IDENTIFIED AS PUBLIC. 7. THE CONTRACTOR SHALL CONTACT THE LOCAL GOVERNING MUNICIPAL PUBLIC WORKS DEPARTMENT, A MINIMUM OF, 48-HOURS IN ADVANCE OF SANITARY, WATER AND STORM CONNECTIONS TO THE MUNICIPAL-OWNED SYSTEM TO SCHEDULE INSPECTIONS. 8. ROUTING OF GAS, ELECTRIC AND TELEPHONE SERVICES ARE SHOWN ON THE ARCHITECTURAL PLANS AND SUBJECT TO CHANGE BASED UPON FINAL REVIEW AND APPROVAL BY RESPECTIVE UTILITY COMPANIES AND OWNER. CONTRACTOR SHALL CONTACT EACH UTILITY COMPANY AND COORDINATE FINAL LOCATIONS FOR ALL UTILITY SERVICES PRIOR TO START OF CONSTRUCTION. 9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE PROPER AUTHORITIES FOR ANY REQUIRED PERMITS, AUTHORIZATIONS, TRAFFIC CONTROL AND ANY PERMIT FEES REQUIRED. 10. SEE UTILITY SPECIFIC PLANS AND CONSTRUCTION DETAILS FOR ADDITIONAL INFORMATION. STORM SEWER NOTES 1. ALL UTILITY WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN (LATEST EDITION AND ADDENDUM) AND ALL STATE AND LOCAL CODES AND SPECIFICATIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHICH SPECIFICATIONS AND CODES APPLY, AND TO COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE LOCAL AND STATE AUTHORITIES. 2. THESE NOTES & SPECIFICATIONS APPLY TO ALL STORM SEWER WORK BEGINNING AT A POINT 5 FEET OUTSIDE OF THE BUILDING WALL, UNLESS OTHERWISE SPECIFIED. 3. WHERE THESE NOTES DO NOT COVER PORTIONS OF THE WORK TO BE UNDERTAKEN, THE STANDARD SPECIFICATIONS FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN, CURRENT EDITION, SHALL GOVERN. 4. ALL MATERIALS SHALL CONFORM TO THE SIZE AND TYPE SHOWN ON THE PLANS OR AS CALLED FOR IN THESE NOTES AND TO APPLICABLE LAWS, CODES, AND ORDINANCES. 5. ALL PRODUCTS AND MATERIALS ARE TO BE NEW, UNDAMAGED, CLEAN, AND IN GOOD CONDITION. EXISTING PRODUCTS AND MATERIALS ARE NOT TO BE REUSED UNLESS INDICATED ON THE PLANS. 6. ALL MATERIALS TO BE UTILIZED IN THE WORK SHALL BE STORED AND HANDLED IN A SAFE MANNER. STORAGE OF MATERIALS SHALL BE DESIGNATED BY THE GENERAL CONTRACTOR. 7. WHEN REQUIRED BY PROPRIETARY PRODUCTS AND MATERIALS, PERFORM ALL WORK IN ACCORDANCE WITH ANY APPLICABLE MANUFACTURER'S INSTRUCTIONS. 8. CONTRACTOR SHALL PROVIDE THE SIZE, TYPE AND CLASS/SCHEDULE OF PIPE AS INDICATED ON THE PLANS AND NOTES. 9. PIPE MATERIALS: REINFORCED CONCRETE PIPE (RCP) PIPE AND FITTINGS SHALL CONFORM TO ASTM C-76 FOR CIRCULAR PIPE AND ASTM C-507 FOR ELLIPTICAL PIPE. STRENGTH CLASSIFICATIONS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: HEIGHT OF COVER (FT): 0 TO 2 2 TO 3 3 TO 6 6 TO 15 15 TO 25 25+ MIN. PIPE CLASS: IV III III III IV ENGINEER TO SPECIFY JOINTS FOR REINFORCED CONCRETE PIPE SHALL BE BELL AND SPIGOT OR TONGUE AND GROOVE. JOINTS SHALL BE PROVIDED WITH RUBBER GASKETS CONFORMING TO ASTM C433. JOINTS FOR ELLIPTICAL PIPE SHALL BE PROVIDED WITH TROWEL ABLE IMPERVIOUS BITUMINOUS JOINT SEALER THAT IS MANUFACTURED FOR SEALING REINFORCED CONCRETE SEWER PIPE JOINTS. WHEN REQUIRED, EXTERNAL SEALING BANDS SHALL MEET THE REQUIREMENTS OF ASTM C877 (TYPE II), AND SHALL BE MAR MAC WRAP, OR APPROVED EQUAL. POLYVINYL CHLORIDE PIPE (PVC) PIPE SHALL CONFORM TO ASTM D-3034 WITH SOLVENT WELD OR ELASTOMERIC JOINTS. PIPE SHALL BE SDR-35, UNLESS OTHERWISE NOTED. PIPE OVER 15 INCHES IN DIAMETER SHALL MEET THE REQUIREMENTS OF ASTM F679-03. DO NOT MIX DIFFERENT MANUFACTURERS' PRODUCTS, OR FITTINGS. HIGH DENSITY DUAL-WALL POLYETHYLENE N-12 CORRUGATED PIPE (HDPE) PIPE SHALL BE AS MANUFACTURED BY ADS OR EQUAL WITH WATERTIGHT JOINTS AND SHALL MEET THE REQUIREMENTS OF AASHTO DESIGNATION M-294 TYPE "S", OR POLYVINYL CHLORIDE (PVC) - CLASS PS46 MEETING AASHTO M278, AS NOTED. IF HDPE PIPE IS USED FOR POND OUTFALLS, A MINIMUM OF THREE (3) SECTIONS (2 STRAPS) SHALL BE STRAPPED TOGETHER. CORRUGATED METAL PIPE (CMP) GALVANIZED PIPE MEETING THE REQUIREMENTS OF AASHTO M36. MINIMUM WALL THICKNESS SHALL BE 16 GA. FOR 12”-24” DIAMETER PIPE, 14 GA FOR 30” AND 36” PIPE, AND 12 GA. FOR 42”-54” DIAMETER PIPE. PROVIDE GALVANIZED CORRUGATED COUPLING BANDS WITH ANGLE CONNECTORS HAVING A MINIMUM OF 2 BOLTS FOR A SOIL TIGHT JOINT. 10. CONNECTION FOR DISSIMILAR PIPE MATERIALS - WHERE NEW SEWER CONNECTS TO AN EXISTING DISSIMILAR PIPE, THE CONNECTION SHALL BE MADE WITH A NO HUB TYPE COUPLINGS MEETING THE REQUIREMENTS OF CISPI 310. COUPLINGS SHALL HAVE NEOPRENE GASKETS WITH STAINLESS STEEL SHIELD, AND MULTIPLE STAINLESS STEEL CLAMPS WITH WORM GEAR TIGHTENING DEVICE. THE COUPLINGS SHALL BE MADE SPECIFICALLY FOR THE TYPE AND SIZE OF PIPE MATERIALS BEING CONNECTED. COUPLINGS SHALL BE FERNCO HUSKY OR APPROVED EQUAL 11. STRUCTURES: STORM SEWER STRUCTURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "STANDARD SPECIFICATIONS". SEE CONSTRUCTION DETAILS FOR FRAME AND GRATE TYPES. STRUCTURE SHOP DRAWINGS SHALL BE SUBMITTED TO PINNACLE ENGINEERING GROUP FOR REVIEW AND APPROVAL PRIOR TO MANUFACTURING AND INSTALLATION OF ALL STORM SEWER STRUCTURES. 12. BACKFILL AND BEDDING: STORM SEWER SHALL BE CONSTRUCTED WITH GRAVEL BACKFILL AND CLASS "B" BEDDING IN ALL PAVED AREAS AND TO A POINT 5 FEET BEYOND THE EDGE OF PAVEMENT. TRENCHES RUNNING PARALLEL TO AND LESS THAN 5 FEET FROM THE EDGE OF PAVEMENT SHALL ALSO REQUIRE GRAVEL BACKFILL. LANDSCAPED AREAS MAY BE BACKFILLED WITH EXCAVATED TRENCH SPOIL MATERIALS IN CONFORMANCE WITH SECTION 8.43.5 OF THE "STANDARD SPECIFICATIONS". MANHOLE FRAMES AND COVERS - SEE CONSTRUCTION DETAILS. 12. TRACER WIRE SHALL BE INSTALLED IN ACCORDANCE WITH STATE AND LOCAL REQUIREMENTS. 13. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). SANITARY SEWER NOTES 1. ALL UTILITY WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN (LATEST EDITION AND ADDENDUM) AND ALL STATE AND LOCAL CODES AND SPECIFICATIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHICH SPECIFICATIONS AND CODES APPLY, AND TO COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE LOCAL AND STATE AUTHORITIES. 2. PIPE - SANITARY SEWER PIPE MATERIAL SHALL BE POLYVINYL CHLORIDE (PVC) MEETING REQUIREMENTS OF ASTM D 3034, SDR-35 (UP TO 15' OF COVER) & SDR-26 (GREATER THAN 15'), WITH INTEGRAL BELL TYPE FLEXIBLE ELASTOMERIC JOINTS, MEETING THE REQUIREMENTS OF ASTM D-3212. 3. BEDDING AND COVER MATERIAL: 3.1. BEDDING AND COVER MATERIAL SHALL CONFORM TO THE APPROPRIATE SECTIONS OF THE "STANDARD SPECIFICATION" WITH THE FOLLOWING MODIFICATION: "COVER MATERIAL SHALL BE THE SAME AS USED FOR BEDDING AND SHALL CONFORM TO SECTION 8.43.2 (A). 3.2. HALL BE PLACED IN A MINIMUM OF THREE SEPARATE LIFTS, OR AS REQUIRED TO ENSURE ADEQUATE COMPACTING OF THESE MATERIALS, WITH ONE LIFT OF BEDDING MATERIAL ENDING AT OR NEAR THE SPRINGLINE OF THE PIPE. THE CONTRACTOR SHALL TAKE CARE TO COMPLETELY WORK BEDDING MATERIAL UNDER THE HAUNCH OF THE PIPE TO PROVIDE ADEQUATE SIDE SUPPORT." 4. BACKFILL: 4.1. BACKFILL MATERIAL AND INSTALLATION SHALL BE IN ACCORDANCE CHAPTER 2.6.0 OF THE "STANDARD SPECIFICATIONS." 4.2. SLURRY BACK FILL UNDER PUBLIC ROAD PAVEMENT. SLURRY LIMITS: FROM TOP OF COVER STONE TO TOP OF THE AGGREGATE BASE ELEVATION. SLURRY TO BE 1-BAG PORTLAND MIX. 4.3. GRAVEL BACKFILL IS REQUIRED IN ALL PAVED AREAS AND TO A POINT 5 FEET BEYOND THE EDGE OF PAVEMENT. TRENCHES RUNNING PARALLEL TO AND LESS THAN 5 FEET FROM THE EDGE OF PAVEMENT SHALL ALSO REQUIRE GRAVEL BACKFILL. 4.4. LANDSCAPED AREAS MAY BE BACKFILLED WITH EXCAVATED TRENCH SPOIL MATERIAL IN CONFORMANCE WITH SECTION 8.43.5 OF THE "STANDARD SPECIFICATIONS." 5. MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH FILE NOS. 12, 13 AND 15 OF THE "STANDARD SPECIFICATIONS" AND ALL STANDARDS AND SPECIFICATIONS OF THE GOVERNING MUNICIPALITY. STRUCTURE SHOP DRAWINGS SHALL BE SUBMITTED TO PINNACLE ENGINEERING GROUP FOR REVIEW AND APPROVAL PRIOR TO MANUFACTURING AND INSTALLATION. 6. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). WATER UTILITY NOTES 1. ALL UTILITY WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR SEWER AND WATER CONSTRUCTION IN WISCONSIN (LATEST EDITION AND ADDENDUM) AND ALL STATE AND LOCAL CODES AND SPECIFICATIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHICH SPECIFICATIONS AND CODES APPLY, AND TO COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE LOCAL AND STATE AUTHORITIES. 2. PIPE MATERIALS: 2.1. WATER MAIN SHALL BE POLYVINYL CHLORIDE (PVC) PIPE MEETING THE REQUIREMENTS OF AWWA STANDARD C-900, CLASS 235, DR-18, WITH CAST IRON O.D. AND INTEGRAL ELASTOMERIC BELL AND SPIGOT JOINTS. 3. STRUCTURES: 3.1. VALVES AND VALVE BOXES - GATE VALVES SHALL BE AWWA GATE VALVES AND MEET THE REQUIREMENTS OF AWWA C-500 AND CHAPTER 8.27.0 OF THE "STANDARD SPECIFICATIONS". GATE VALVES AND VALVE BOXES SHALL CONFORM TO GOVERNING MUNICIPAL PLUMBING ORDINANCES. 3.2. HYDRANTS - HYDRANTS MEET THE REQUIREMENTS OF FILE NO. 38 OF THE "STANDARD SPECIFICATIONS" AND SHALL CONFORM TO GOVERNING MUNICIPAL FIRE PROTECTION ORDINANCES. 3.3. ALL DUCTILE FITTINGS, VALVES, AND VALVE BOXES SHALL CONFORM WITH ALL GOVERNING MUNICIPAL REQUIRMENTS AND SHALL BE TRIPLE WRAPPED AND SECURELY TAPED AROUND WITH POLYETHYLENE AS SPECIFIED IN CHAPTER 4.4.4 AND 8.21.0 OF THE "STANDARD SPECIFICATIONS". 4. BACKFILL, BEDDING AND COVER MATERIAL: 4.1. PIPE BEDDING AND COVER MATERIAL SHALL BE SAND, CRUSHED STONE CHIPS OR CRUSHED STONE SCREENINGS CONFORMING TO CHAPTER 8.43.2 OF THE "STANDARD SPECIFICATIONS". 4.2. BACKFILL - BACKFILL MATERIAL AND INSTALLATION SHALL BE IN ACCORDANCE WITH CHAPTER 2.6.0 OF THE "STANDARD SPECIFICATIONS". 4.3. GRAVEL BACKFILL IS REQUIRED IN ALL PAVED AREAS AND TO A POINT 5 FEET BEYOND THE EDGE OF PAVEMENT. TRENCHES RUNNING PARALLEL TO AND LESS THAN 5 FEET FROM THE EDGE OF PAVEMENT SHALL ALSO REQUIRE GRAVEL BACKFILL. 4.4. SLURRY BACK FILL IS REQUIRED UNDER PUBLIC ROAD PAVEMENT. SLURRY PLACEMENT LIMITS: FROM TOP OF COVER STONE TO TOP OF THE AGGREGATE BASE ELEVATION. SLURRY TO BE 1-BAG PORTLAND MIX. 4.5. LANDSCAPED AREAS MAY BE BACKFILLED WITH EXCAVATED TRENCH SPOIL MATERIAL IN CONFORMANCE WITH SECTION 8.43.5 OF THE "STANDARD SPECIFICATIONS”. 5. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). EROSION & SEDIMENT CONTROL NOTES 1. ALL EROSION CONTROL PLANS FOR A CONSTRUCTION AND POST CONSTRUTION SITE SHALL BE IN ACCORDANCE WITH “CH. NR 216.47, AND NR 151 OF THE WISCONSIN ADMININSTRATION CODE”. ALL EROSION CONTROL, SITE STABILIZATION PRACTICES, AND SEDIMENT CONTROL PRACTICES USED SHALL FOLLOW WISCONSIN DEPARTMENT OF NATURAL RESOURCES (WDNR) TECHNICAL STANDARDS AND BEST MANAGEMENT PRACTICES FOR CONSTRUCTION SITES. 2. ALL EROSION CONTROL AND STORMWATER PRODUCTS SHALL FOLLOW THE WISCONSIN DEPARTMENT OF TRANSPORTATION PRODUCT ACCEPTIBILITY LIST (PAL) FOR EROSION MATS, TACKTIFIERS, SOIL STABILIZERS, INLET PROTECTION, AND TEMPORARY DITCH CHECKS FOR PRODUCTS AND INSTALLATION STANDARDS. 3. ALL CONSTRUCTION SHALL ADHERE TO THE REQUIREMENTS SET FORTH IN EPA'S NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) STORMWATER GENERAL PERMIT ("WPDES" PERMIT NO. WI-S067831-4) FOR CONSTRUCTION SITE LAND DISTURBANCE ACTIVITIES. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL TECHNICAL STANDARDS AND PROVISIONS IN EFFECT AT THE TIME OF CONSTRUCTION. THESE PROCEDURES AND STANDARDS SHALL BE REFERRED TO AS BEST MANAGEMENT PRACTICES (BMP'S). IT IS THE RESPONSIBILITY OF ALL CONTRACTORS ASSOCIATED WITH THE PROJECT TO OBTAIN A COPY OF, AND UNDERSTAND, THE BMP'S PRIOR TO THE START OF CONSTRUCTION ACTIVITIES. 4. THE EROSION CONTROL MEASURES INDICATED ON THE PLANS ARE THE MINIMUM REQUIREMENTS. ADDITIONAL CONTROL MEASURES AS DIRECTED BY OWNER/ENGINEER OR GOVERNING AGENCIES SHALL BE INSTALLED WITHIN 24 HOURS OF REQUEST. 5. POST WDNR CERTIFICATE OF PERMIT COVERAGE ON SITE AND MAINTAIN UNTIL CONSTRUCTION ACTIVITIES HAVE CEASED, THE SITE IS STABILIZED, AND A NOTICE OF TERMINATION IS FILES WITH WDNR. 6. KEEP A COPY OF THE CURRENT EROSION CONTROL PLAN ON SITE THROUGHOUT THE DURATION OF THE PROJECT. 7. KEEP A COPY OF THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN THE FIELD OFFICE THROUGHOUT THE DURATION OF THE PROJECT. ANY MODIFICATIONS TO THE APPROVED SWPPP IN ORDER TO MEET UNFORESEEN FIELD CONDITIONS ARE ALLOWED IF MODIFICATIONS CONFORM TO APPLICABLE BMP'S. ALL MODIFICATIONS MUST BE APPROVED BY OWNER/ENGINEER/GOVERNING AGENCY PRIOR TO DEVIATION OF THE APPROVED PLAN. 8. INSTALL PERIMETER EROSION CONTROL MEASURES (SUCH AS CONSTRUCTION ENTRANCES, SILT FENCE AND EXISTING INLET PROTECTION) PRIOR TO ANY SITE WORK, INCLUDING GRADING OR DISTURBANCE OF EXISTING SURFACE COVER, AS SHOWN ON PLAN IN ORDER TO PROTECT ADJACENT PROPERTIES/STORM SEWER SYSTEMS FROM SEDIMENT TRANSPORT. 9. CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT ALL LOCATIONS OF VEHICLE INGRESS/EGRESS POINTS. CONTRACTOR IS RESPONSIBLE TO COORDINATE LOCATION(S) WITH THE PROPER AUTHORITIES, PROVIDE NECESSARY FEES AND OBTAIN ALL REQUIRED APPROVALS OR PERMITS. ADDITIONAL CONSTRUCTION ENTRANCES OTHER THAN AS SHOWN ON THE PLANS MUST BE APPROVED BY THE APPLICABLE GOVERNING AGENCIES PRIOR TO INSTALLATION. 10. PAVED SURFACES ADJACENT TO CONSTRUCTION ENTRANCES SHALL BE SWEPT AND/OR SCRAPED TO REMOVE ACCUMULATED SOIL, DIRT AND/OR DUST IMMEDIATELY AND AS REQUESTED BY GOVERNING AGENCIES. 11. ALL EXISTING STORM SEWER FACILITIES THAT WILL COLLECT RUNOFF FROM DISTURBED AREAS SHALL BE PROTECTED TO PREVENT SEDIMENT DEPOSITION WITHIN STORM SEWER SYSTEMS. INLET PROTECTION SHALL BE IMMEDIATELY FITTED AT THE INLET OF ALL EXISTING AND INSTALLED STORM SEWER STRUCTURES WITHIN THE PROJECT ARE OR AS DIRECTED BY THE ENGINEER. ALL INLETS, STRUCTURES, PIPES, AND SWALES SHALL BE KEPT CLEAN AND FREE OF SEDIMENTATION AND DEBRIS. 12. EROSION CONTROL FOR UTILITY CONSTRUCTION (STORM SEWER, WATER MAIN, ETC.) OUTSIDE OF THE PERIMETER CONTROLS SHALL INCORPORATE THE FOLLOWING: 12.1. PLACE EXCAVATED TRENCH MATERIAL ON THE HIGH SIDE OF THE TRENCH. 12.2. BACKFILL, COMPACT AND STABILIZE THE TRENCH IMMEDIATELY AFTER PIPE CONSTRUCTION. 12.3. DISCHARGE TRENCH WATER INTO A SEDIMENTATION BASIN OR FILTERING TANK IN ACCORDANCE WITH BMP'S PRIOR TO RELEASE INTO STORM SEWER OR DITCHES. 13. AT A MINIMUM, SEDIMENT BASINS AND NECESSARY TEMPORARY DRAINAGE PROVISIONS SHALL BE CONSTRUCTED AND OPERATIONAL BEFORE BEGINNING OF SIGNIFICANT MASS GRADING OPERATIONS TO PREVENT OFFSITE DISCHARGE OF UNTREATED RUNOFF. 14. ALL WATERCOURSES AND WETLANDS SHALL BE PROTECTED WITH SILT FENCE TO PREVENT ANY DIRECT DISCHARGE FROM DISTURBED SOILS, IF APPLICABLE. 15. ALL TEMPORARY AND PERMANENT EROSION CONTROL MEASURES MUST BE MAINTAINED AND REPAIRED AS NEEDED. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INSPECTION AND REPAIR DURING CONSTRUCTION. THE OWNER WILL BE RESPONSIBLE IF EROSION CONTROL IS REQUIRED AFTER THE CONTRACTOR HAS COMPLETED THE PROJECT. 16. TOPSOIL STOCKPILES SHALL HAVE A PERIMETER BERM OR TRENCH AND SILT FENCE INSTALLED TO CONTROL SILT. IF TOPSOIL STOCKPILE REMAINS UNDISTURBED FOR MORE THAN SEVEN (7) DAYS, TEMPORARY SEEDING AND STABILIZATION IS REQUIRED. 17. EROSION CONTROL MEASURES TEMPORARILY REMOVED FOR UNAVOIDABLE CONSTRUCTION ACTIVITIES SHALL BE IN WORKING ORDER IMMEDIATELY FOLLOWING COMPLETION OF SUCH ACTIVITIES OR PRIOR TO THE COMPLETION OF EACH WORKDAY, WHICH EVER OCCURS FIRST. 18. MAINTAIN SOIL EROSION CONTROL DEVICES THROUGH THE DURATION OF THIS PROJECT. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN THIRTY (30) DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED. DISTURBANCES ASSOCIATED WITH EROSION CONTROL REMOVAL SHALL BE IMMEDIATELY STABILIZED. 19. PUMPS MAY BE USED AS BYPASS DEVICES. IN NO CASE SHALL PUMPED WATER BE DIVERTED OUTSIDE THE PROJECT LIMITS. PUMP DISCHARGE SHALL BE DIRECTED INTO AN APPROVED FILTER BAG OR APPROVED SETTLING DEVICE. 20. GRADING EFFORTS SHALL BE CONDUCTED IN SUCH A MANNER AS TO MINIMIZE EROSION. EROSION AND SEDIMENT CONTROL MEASURES SHALL CONSIDER THE TIME OF YEAR, SITE CONDITIONS, AND THE USE OF TEMPORARY OR PERMANENT MEASURES. ALL DISTURBED AREAS THAT WILL NOT BE WORKED FOR A PERIOD OF SEVEN (7) DAYS REQUIRE TEMPORARY SEEDING FOR EROSION CONTROL. SEEDING FOR EROSION CONTROL SHALL BE IN ACCORDANCE WITH TECHNICAL STANDARDS. 21. ALL DISTURBED SLOPES 4:1 OR GREATER, SHALL BE STABILIZED WITH NORTH AMERICAN GREEN S75BN EROSION MATTING (OR APPROVED EQUAL) AND ALL CHANNELS SHALL BE STABILIZED WITH NORTH AMERICAN GREEN C125BN (OR APPROVED EQUAL) OR APPLICATION OF AN APPROVED POLYMER SOIL STABILIZATION TREATMENT OR A COMBINATION THEREOF, AS REQUIRED. EROSION MATTING AND/OR NETTING USED ONSITE SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S GUIDELINES. 22. DURING PERIODS OF EXTENDED DRY WEATHER, THE CONTRACTOR SHALL KEEP A WATER TRUCK ON SITE FOR THE PURPOSE OF WATERING DOWN SOILS WHICH MAY OTHERWISE BECOME AIRBORNE.THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING WIND EROSION (DUST) DURING CONSTRUCTION AT HIS/HER EXPENSE. 23. DISTURBED AREAS AND AREAS USED FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO PRECIPITATION SHALL BE VISUALLY INSPECTED FOR EVIDENCE OF, OR THE POTENTIAL FOR, POLLUTANTS ENTERING THE DRAINAGE SYSTEM ON A DAILY BASIS. 24. QUALIFIED PERSONNEL (PROVIDED BY THE GENERAL/PRIME CONTRACTOR) SHALL INSPECT DISTURBED AREAS OF THE CONSTRUCTION SITE THAT HAVE NOT BEEN FINALLY STABILIZED AND EROSION AND SEDIMENT CONTROLS WITHIN 24 HOURS OF ALL 0.5-INCH, OR MORE, PRECIPITATION EVENTS WITH A MINIMUM INSPECTION INTERVAL OF ONCE EVERY SEVEN (7) CALENDAR DAYS IN THE ABSENCE OF A QUALIFYING RAIN OR SNOWFALL EVENT. REPORTING SHALL BE IN ACCORDANCE WITH OF THE GENERAL PERMIT. CONTRACTOR SHALL IMMEDIATELY ARRANGE TO HAVE ANY DEFICIENT ITEMS REVEALED DURING INSPECTIONS REPAIRED/REPLACED. 25. SEE ADDITIONAL NOTES AND DETAILS ON THE CONSTRUCTION DETAIL SHEET(S). E E E 120.02' LOT 2 C.S.M. NO. 9530 1,059,970 SQ. FT. 24.3336 ACRES - VACANT- NO BUILDINGS OBSERVED UNPLATTED LANDS OWNER: MILWAUKEE COUNTY DEPARTMENT OF PARKS RECREATION AND CULTURE TAX KEY #9509998001 "ROOT RIVER PARKWAY NORTH" N88°36'18"E 2631.37' S S S S S S DD S DD D N00°21'57"W 2653.52' POND PROPERTY LINE PROPERTY LINE XXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXX XXX XXXX XXXX WEST ELM ROAD XXXXX XXXX XXX XXXX XXXX SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SHEET C-5 SHEET C-4 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINE PROPERTY LINE 141,812 S.F. OFDISTURBED AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EXISTING CONDITIONS & DEMO PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EXISTING CONDITIONS & DEMOLITION PLAN OVERVIEW 1CITY COMMENTS11/09/26C-3 1" = 80' EXISTING CONDITIONS & DEMOLITION PLAN OVERVIEW FRANKLIN SIX SIBS 1" = 80' 0160' GRAPHICAL SCALE (FEET) NORTH THE INFORMATION SHOWN ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATIONS AS TO THE TYPE AND LOCATION OF UNDERGROUND UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. IF ADDITIONAL UTILITIES ARE KNOWN TO EXIST IN THE PROPERTY, THE OWNER WILL PROVIDE EXISTING PLANS OF OTHER UTILITIES SERVING THE SITE AND THE BUILDING THAT OTHERWISE CANNOT BE LOCATED BY A VISUAL OBSERVATION OF THE PROPERTY OR OF WHICH THE SURVEYOR WOULD HAVE NO KNOWLEDGE. CONTRACTOR RESPONSIBILITY: EXISTING CONDITIONS SURVEY PROVIDED BY PINNACLE ENGINEERING GROUP. ALTHOUGH PEG HAS NO REASON TO BELIEVE THE SURVEY IS INACCURATE, PEG MAKES NO WARRANTS THAT EXISTING INFORMATION CONTAINED WITHIN THESE PLANS IS ALL-INCLUSIVE OR ACCURATE. CONTRACTOR SHALL UNDERTAKE NECESSARY EFFORTS TO VERIFY THE EXISTING CONDITIONS PRIOR TO THE START OF MATERIAL PROCUREMENT AND CONSTRUCTION EFFORTS/ACTIVITIES. LEGEND EASEMENT LINE CLEANOUT FIRE HYDRANT LIGHTING SANITARY SEWER STORM SEWER WATER MAIN BUFFALO BOX FORCE MAIN ELECTRICAL TRANSFORMER CONTOUR TREE POWER POLE STREET SIGN GAS MAIN TELEPHONE LINE CONCRETE SIDEWALK VALVE BOX ELECTRICAL CABLE OR PEDESTAL SANITARY MANHOLE STORM MANHOLE CATCH BASIN INLET PRECAST FLARED END SECTION VALVE VAULT CONCRETE HEADWALL POWER POLE WITH LIGHT GUY WIRE W EXISTING CONDITIONS SURVEY: LEGEND REMOVE EXISTING ASPHALT (SEE PLAN FOR DESCRIPTION) CLEARING & GRUBBING REMOVE OR ABANDON EXISTING UTILITY (SEE PLAN FOR DESCRIPTION) REMOVE EXISTING CURB & GUTTER REMOVE EXISTING TREE FULL-DEPTH SAWCUT XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX LIMITS OF DISTURBANCE REMOVE / REPLACE EXISTING UTILITY STRUCTURE CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET ### RIPRAP RIPRAP E E 721 720 719 718 717 716 715 715 715 715 715 715 TREELINE ASPHALT PATH EAST OF PROPERTY LINE ASPHALT PAVEMENT S 715 717 716718 721 713 714 713 713 SANITARY MANHOLERIM=717.0312" N=692.0912" S=691.88 CONCRETE CURB ((R) S00°22'00"W 1,505.42' CSM 9530) 716 717 718 714 712 713 711 711 712 713 713714 714 713 15" CULVERT INV=715.00 15" CULVERT INV=712.88 4" INV=712.034" INV=714.154" INV=716.69 CURB INLETRIM=715.5712" N=713.17 CURB INLETRIM=715.5012" S=713.1012' E=713.00 CURB INLETRIM=715.50 12" W=713.0012" S=713.1015" SE=713.00 CURB INLETRIM=715.6412" N=713.24CURB INLETRIM=717.3812" E=714.9812" S=715.08CURB INLETRIM=717.4912" N=715.29 CURB INLETRIM=717.5312" N=715.18 CURB INLETRIM=717.4212" S=714.9215" E=714.9212' W=714.92 CURB INLETRIM=719.6612" N=716.4612" E=716.41 CURB INLETRIM=719.4712" S=714.77 CURB INLETRIM=719.6812" W=716.0815" NE=715.98 CONCRETE STORM STRUCTURERIM=715.306" NE=710.754" S=712.357" WEEP=714.37 CONCRETE STORMSTRUCTURERIM=717.096" N=712.194" S=713.995" WEEP= 715.91 15" CULVERTINV=715.89 REMOVE ±1,541 S.F OF EXISTING ASPHALT WALK REMOVE ±1,349 S.F OF EXISTING ASPHALT WALK EXISTING FIBER OPTIC CABLE TO BE REMOVED. COORDINATE WITH APPROPRIATE DRY UTILITY PROVIDER PROPERTY LINE XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX SAWCUT & REMOVE ±105 L.F OF EXISTING CURB & GUTTER TO NEAREST JOINT SAWCUT ±79 L.F. OFEXISTING ASPHALT SAWCUT & REMOVE ±112 L.F OF EXISTING CURB & GUTTER TO NEAREST JOINT SAWCUT ±99 L.FOF EXISTING ASPHALT REMOVE & REPLACE±200 S.F OF EXISTING ASPHALT PATH XXXXXXXXX XXXXXXXXXX XXXXXXXXXXXX SAWCUT, REMOVE, AND REPLACE ±289 S.F OF EXISTING PAVEMENT IN KIND. CONTRACTOR TO COORDINATE TRAFFIC CONTROL WITH CITY OF FRANKLIN. WEST ELM ROAD REMOVE & REPLACE ±200 S.FOF EXISTING ASPHALT PATH SAWCUT & REMOVE ±20 L.F OF EXISTING CURB TO NEAREST JOINT SAWCUT, REMOVE, AND REPLACE ±200 S.F OF EXISTING PAVEMENT IN KIND. CONTRACTOR TO COORDINATE TRAFFIC CONTROL WITH CITY OF FRANKLIN. XXXXXX XXXXXXX XXXXXXXXXXXX SAWCUT & REMOVE ±20 L.F. OF EXISTING CURB TO NEAREST JOINT EXISTING HYDRANT TO BE REMOVED & SALVAGED FOR RELOCATION EXISTING INLETS TO REMAIN EXISTING INLETS TO REMAIN ELECTRICAL STRUCTURE TO BE RELOCATED DURING SIDEWALK REPLACEMENT. OORDINATE WITH APPROPRIATE DRY UTILITY PROVIDER EXISTING LIGHT POLE TO BE REMOVED & RELOCATED (TYP) COORDINATE WITH APPROPRIATE DRY UTILITY PROVIDER EXISTING OVERHEAD WIRETO REMAIN EXISTING OVERHEAD WIRETO REMAIN POWER POLE AND ASSOCIATED OVERHEAD WIRES TO REMAIN 605,063 S.F. OF DISTURBED AREA 605,063 S.F. OF DISTURBED AREA 605,063 S.F. OF DISTURBED AREA CURB INLETRIM=717.4912" N=715.29 EXISTING SIGN TO BE REMOVED & SALVAGED FOR RELOCATION MATCH LINE SEE SHEET C-5 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) LOT 2 C.S.M. NO. 95301,059,970 SQ. FT.24.3336 ACRES - VACANT- NO BUILDINGSOBSERVED PROPERTY LINE PROPERTY LINE 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENTACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EXISTING CONDITIONS & DEMO PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EXISTING CONDITIONS & DEMOLITION PLAN 1CITY COMMENTS11/09/26C-4 1" = 30' EXISTING CONDITIONS & DEMOLITION PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH THE INFORMATION SHOWN ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATIONS AS TO THE TYPE AND LOCATION OF UNDERGROUND UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. IF ADDITIONAL UTILITIES ARE KNOWN TO EXIST IN THE PROPERTY, THE OWNER WILL PROVIDE EXISTING PLANS OF OTHER UTILITIES SERVING THE SITE AND THE BUILDING THAT OTHERWISE CANNOT BE LOCATED BY A VISUAL OBSERVATION OF THE PROPERTY OR OF WHICH THE SURVEYOR WOULD HAVE NO KNOWLEDGE. CONTRACTOR RESPONSIBILITY: EXISTING CONDITIONS SURVEY PROVIDED BY PINNACLE ENGINEERING GROUP. ALTHOUGH PEG HAS NO REASON TO BELIEVE THE SURVEY IS INACCURATE, PEG MAKES NO WARRANTS THAT EXISTING INFORMATION CONTAINED WITHIN THESE PLANS IS ALL-INCLUSIVE OR ACCURATE. CONTRACTOR SHALL UNDERTAKE NECESSARY EFFORTS TO VERIFY THE EXISTING CONDITIONS PRIOR TO THE START OF MATERIAL PROCUREMENT AND CONSTRUCTION EFFORTS/ACTIVITIES. LEGEND EASEMENT LINE CLEANOUT FIRE HYDRANT LIGHTING SANITARY SEWER STORM SEWER WATER MAIN BUFFALO BOX FORCE MAIN ELECTRICAL TRANSFORMER CONTOUR TREE POWER POLE STREET SIGN GAS MAIN TELEPHONE LINE CONCRETE SIDEWALK VALVE BOX ELECTRICAL CABLE OR PEDESTAL SANITARY MANHOLE STORM MANHOLE CATCH BASIN INLET PRECAST FLARED END SECTION VALVE VAULT CONCRETE HEADWALL POWER POLE WITH LIGHT GUY WIRE W EXISTING CONDITIONS SURVEY: LEGEND REMOVE EXISTING ASPHALT (SEE PLAN FOR DESCRIPTION) CLEARING & GRUBBING REMOVE OR ABANDON EXISTING UTILITY (SEE PLAN FOR DESCRIPTION) REMOVE EXISTING CURB & GUTTER REMOVE EXISTING TREE FULL-DEPTH SAWCUT XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX LIMITS OF DISTURBANCE REMOVE / REPLACE EXISTING UTILITY STRUCTURE CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET ### RIPRAP E E LOT 2 C.S.M. NO. 9530 1,059,970 SQ. FT. 24.3336 ACRES - VACANT- NO BUILDINGS OBSERVED 714 713 712 710 705 705 705 705 705 704 703 702 714 713 CONCRETE CURB 710 TREELINE TREELINE S S DD S DD 714 715 715 715 715 715 717 716715 714 703705 707710 SANITARY MANHOLE RIM=716.54 12" N=694.24 12" S=694.10 SANITARY MANHOLE RIM=713.82 12" N=693.07 12" S=693.0710" W=695.89 EDGE OF ICE ELEV=700.83 ((R) N00°22'00"W 1,518.01' CSM 9530) N00°21'57"W 2653.52' POND 712 709 708 707 706 704705 702703 701 711 710 709 708 707 706 705705 712 713 713714 714 713 713 712 714 712 713 712 713 715 714 714 713 713 717 716 717 715 706 707 708708 707 708 706 704 703 702 701 716 SANITARY MANHOLE RIM=714.74 12" N=693.49 12" S=693.49 15" CULVERT INV=710.94 30" CULVERT INV=708.26 15" CULVERT INV=712.66 15" CULVERT INV=713.33 4" INV=714.85 4" INV=713.80 4" INV=712.56 6" INV (BURIED)=709.24 CURB INLET RIM=716.27 12" E=713.72 CURB INLET RIM=716.40 12" W=713.55 15" E=713.55 12" N=713.70 CURB INLET RIM=716.48 12" S=713.93 CURB INLET RIM=715.41 12" E=712.86 CURB INLET RIM=715.34 12" W=712.59 15" E=712.59 CURB INLET RIM=714.20 12" S=711.85 CURB INLET RIM=714.08 12" N=711.83 12' E=711.63 CURB INLET RIM=714.08 12" W=711.63 12' N=711.63 15" NE= 711.63 CURB INLET RIM=713.36 12" E=710.86 CURB INLET RIM=713.44 12" W=710.84 15" E=710.84 STORM MANHOLE RIM=708.65 21" SE=700.63 TOP OF WEIR WALL=705.79 STORM MANHOLE RIM=709.60 30" N=705.02 30" E=705.02 STORM MANHOLE RIM=715.92 30" S=707.05 30" W=706.98 CONCRETE STORM STRUCTURE RIM=716.998" S=710.69 4" N=714.54 7" WEEP=716.14 CONCRETE STORM STRUCTURE RIM=716.79 8" N=710.44 4" N=713.24 15" S=710.29 7" WEEP=715.22 CONCRETE STORM STRUCTURE RIM=714.52 4" NW=712.02 15" N=709.52 15" S=709.52 5" WEEP=714.06 CONCRETE STORM STRUCTURERIM=713.00 4" S=709.70 15" N=709.10 5" WEEP=712.25 30" CULVERT INV=705.01 21" CULVERT INV=700.81 CURB INLETRIM=714.16 12" S=711.71 STORM MANHOLE RIM=708.65 21" NW=700.51 TOP OF WEIR WALL=705.79 CONCRETE STORM STRUCTURERIM=714.10 4" NW=710.90 15" N=708.70 15" S=708.70 6" WEEP=713.33 15" INV=711.57 REMOVE ±1,259 S.F OF EXISTING ASPHALT WALK XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX SAWCUT & REMOVE ±106 L.F OF EXISTING CURB & GUTTER TO NEAREST JOINT REMOVE & REPLACE ±200 S.F OF EXISTING ASPHALT PATH SAWCUT & REMOVE ±20 L.F OF EXISTING CURB TO NEAREST JOINT XXXXXXXXXXXXXXXXX XXXXXXXXXXXXX EXISTING INLET TO REMAIN EXISTING STORM SEWER TO REMAIN POWER POLE AND ASSOCIATED OVERHEAD WIRES TO REMAIN EXISTING LIGHT POLE TO BE REMOVED & RELOCATED (TYP) COORDINATE WITH APPROPRIATE DRY UTILITY PROVIDER SOUTH HICKORY STREET (120' PUBLIC R.O.W.) 605,063 S.F. OFDISTURBED AREA 605,063 S.F. OF DISTURBED AREA SAWCUT ±80 L.F OF EXISTING ASPHALT MATCH LINE SEE SHEET C-4 SAWCUT, REMOVE, AND REPLACE ±268 S.F OF EXISTING PAVEMENT IN KIND. CONTRACTOR TO COORDINATE TRAFFIC CONTROL WITH CITY OF FRANKLIN. PROPERTY LINE PROPERTY LINE STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 16.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 141,812 S.F. OFDISTURBED AREA 20' STORMWATER DRAINAGE EASEMENTPER CSM 9530 AND PER DOC NO. 11346144 LEGEND EASEMENT LINE CLEANOUT FIRE HYDRANT LIGHTING SANITARY SEWER STORM SEWER WATER MAIN BUFFALO BOX FORCE MAIN ELECTRICAL TRANSFORMER CONTOUR TREE POWER POLE STREET SIGN GAS MAIN TELEPHONE LINE CONCRETE SIDEWALK VALVE BOX ELECTRICAL CABLE OR PEDESTAL SANITARY MANHOLE STORM MANHOLE CATCH BASIN INLET PRECAST FLARED END SECTION VALVE VAULT CONCRETE HEADWALL POWER POLE WITH LIGHT GUY WIRE W EXISTING CONDITIONS SURVEY: LEGEND REMOVE EXISTING ASPHALT (SEE PLAN FOR DESCRIPTION) CLEARING & GRUBBING REMOVE OR ABANDON EXISTING UTILITY (SEE PLAN FOR DESCRIPTION) REMOVE EXISTING CURB & GUTTER REMOVE EXISTING TREE FULL-DEPTH SAWCUT XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX LIMITS OF DISTURBANCE DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EXISTING CONDITIONS & DEMO PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EXISTING CONDITIONS & DEMOLITION PLAN 1CITY COMMENTS11/09/26C-5 1" = 30' EXISTING CONDITIONS & DEMOLITION PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH THE INFORMATION SHOWN ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATIONS AS TO THE TYPE AND LOCATION OF UNDERGROUND UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO. IF ADDITIONAL UTILITIES ARE KNOWN TO EXIST IN THE PROPERTY, THE OWNER WILL PROVIDE EXISTING PLANS OF OTHER UTILITIES SERVING THE SITE AND THE BUILDING THAT OTHERWISE CANNOT BE LOCATED BY A VISUAL OBSERVATION OF THE PROPERTY OR OF WHICH THE SURVEYOR WOULD HAVE NO KNOWLEDGE. CONTRACTOR RESPONSIBILITY: EXISTING CONDITIONS SURVEY PROVIDED BY PINNACLE ENGINEERING GROUP. ALTHOUGH PEG HAS NO REASON TO BELIEVE THE SURVEY IS INACCURATE, PEG MAKES NO WARRANTS THAT EXISTING INFORMATION CONTAINED WITHIN THESE PLANS IS ALL-INCLUSIVE OR ACCURATE. CONTRACTOR SHALL UNDERTAKE NECESSARY EFFORTS TO VERIFY THE EXISTING CONDITIONS PRIOR TO THE START OF MATERIAL PROCUREMENT AND CONSTRUCTION EFFORTS/ACTIVITIES. REMOVE / REPLACE EXISTING UTILITY STRUCTURE CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET ### ROAD WEST ELM 40'70' EXISTING RIGHT OF WAY EXISTING RIGHT OF WAY SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SOUTH HICKORY STREET (120' PUBLIC R.O.W.) POND PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D PROPERTY LINE PROPERTY LINE SHEET C-8 PROPERTY LINE PROPERTY LINEPROPERTY LINE SHEET C-7 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI SITE DIMENSIONAL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM SITE DIMENSIONAL & PAVING PLAN OVERVIEW 1CITY COMMENTS11/09/26C-6 1" = 60' SITE DIMENSIONAL & PAVING PLAN OVERVIEW FRANKLIN SIX SIBS # D.I.D LIGHT DUTY PAVEMENT LEGEND 8"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 3-1/2" ASPHALTIC CONC. (2 LIFTS) 1-3/4" BINDER COURSE (4 LT 58-28 S) 1-3/4" SURFACE COURSE (5 LT 58-28 S) HEAVY DUTY PAVEMENT 12"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"ASPHALTIC CONC. (2 LIFTS) 2-1/4" BINDER COURSE (3 MT 58-28 S) 1-3/4" SURFACE COURSE (4 MT 58-28 S) HEAVY DUTY CONCRETE PAVEMENT 6"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 8"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE WITH 6X6X6 GAUGE STEEL MESH) 4" WIDE SOLID WHITE STRIPEA 4" DIAGONAL WHITE STRIPE AT 45° SPACED 2' O.C.B 18" WIDE CONC. CURB & GUTTER (SEE DETAIL)C 18" WIDE REVERSE PITCH CONC. CURB & GUTTER (SEE DETAIL)D 30" WIDE CONC. CURB & GUTTER (SEE DETAIL)E BUILDING DOOR SLAB (2% MAX. SLOPE WITHIN DRIVE IN OR MAN DOOR)F ADA COMPLIANT CURB RAMP (SEE DETAIL)G R7-8 HANDICAP PARKING SIGN WITH BOLLARD (SEE DETAIL)H ADA COMPLIANT STALL INSIGNIA, WHITEI DRIVE-IN-DOOR PARKING COUNT (FOR INFORMATIONAL ONLY, NOT TO BE PAINTED) CONCRETE SIDEWALK (PRIVATE) JDEPRESS & TAPER CURB HEAD. INSTALL NEENAH DETACTABLE WARNING PLATE AT SIDEWALK. KINTEGRAL CURB (SEE DETAIL) ASPHALT PAVEMENT IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS ASPHALT WALK IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS 5"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE) MAN DOOR LBOLLARD (SEE DETAIL) 1" = 60' 0120' GRAPHICAL SCALE (FEET) NORTH SITE DATA EXISTING SITE AREA: 24.33 AC (1,059,970 S.F.) PASSENGER CAR PARKING: 172 STALLS (8 ADA) TRAILER PARKING: 51 STALLS DOCK STALLS:32 STALLS BUILDING AREAS: 5.87 AC (256,000 S.F) GREENSPACE AREA:12.84 AC (559,553 S.F.) TOTAL IMPERVIOUS AREA:11.47 AC (500,417 S.F.) GREEN SPACE (%)52.78% SOUTH HICKORY STREET (120' PUBLIC R.O.W.) PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D MATCH LINE SEE SHEET C-8 18.0' (TYP) 10.0'(TYP) 18.0' (TYP) 10.0'(TYP) 10.0'(TYP) 18.0' (TYP) 10.0'(TYP) 18.0' (TYP) 10.0'(TYP) 18.0' (TYP) 24.0' 24.0' 24.0' 10.0'(TYP) 12.0' (TYP) 55.0'(TYP) 12.0'(TYP) 12.0'(TYP) 30.0' 50.0' (TYP) R35.0' R9.0' R50.0' R20.0' R5.0' (TYP) R5.0' (TYP) R5.0' (TYP) R5.0' (TYP) R44.0' F F F F FFFF 5.0' 60.0' (TYP)16.0' 30.0' R40.0' 10.0'TAPER 10.0' TAPER 2.0' R10.0' R10.0' 10.0' 20.0' 10.0' 20.0' 10.0' 14.5' R40.0' R40.0' 2.0' 5.0' PROPERTY LINE AAA B B I I 52 15 1416 16 K K J H G J H G E E E D D D D DD D D C C C D D 166.5' 33.0' 33.0' 10.0' TAPER 10.0' TAPER 80.0' 10.0' 55.0'(TYP) 80.0' 3.3' 8.0' (TYP) 85.0' 10.0'10.0' 8.0' (TYP) 5.3' 16.0' 16.0' 16.0'16.0'16.0' 16.0' 16.0' 5.1'5.0' 12.0'(TYP) 12.0'(TYP) 12.0'(TYP) 12.0'(TYP) 5.1' F F F FF F F 5.0' 60.0' (TYP) 50.0' (TYP) R9.0' R35.0' 60.0' (TYP) 50.0' (TYP) C LL L LL L L 5.1' 24.0' R40.0' 5.0' 5.0' FE E E105.1' 112.0' 10.0' 9.7' 16 15 18.0' (TYP) F F 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 10.0' SIDE BUILDING SETBACK 25.0' REAR BUILDING SETBACK FF F 163.5' 6.0' 6.0' 166.5' 35.0' 35.0' 5.0' 5.0' 10.0' 5.0' 5.0' 7.0'5.0' 18.3' 5.0' 7.0' 5.0' 14.4' 8.0' (TYP) 8.0' (TYP) 10.0' PROPERTY LINE PROPOSED LIGHT POLE (TYP) 30.0' 5.0' 15.0' 6.0' BICYCLE PARKING (5) VISION CLEARANCE AREA VISION CLEARANCE AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI SITE DIMENSIONAL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM SITE DIMENSIONAL & PAVING PLAN 1CITY COMMENTS11/09/26C-7 1" = 30' SITE DIMENSIONAL & PAVING PLAN FRANKLIN SIX SIBS # D.I.D LIGHT DUTY PAVEMENT LEGEND 8"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 3-1/2" ASPHALTIC CONC. (2 LIFTS) 1-3/4" BINDER COURSE (4 LT 58-28 S) 1-3/4" SURFACE COURSE (5 LT 58-28 S) HEAVY DUTY PAVEMENT 12"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"ASPHALTIC CONC. (2 LIFTS) 2-1/4" BINDER COURSE (3 MT 58-28 S) 1-3/4" SURFACE COURSE (4 MT 58-28 S) HEAVY DUTY CONCRETE PAVEMENT 6"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 8"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE WITH 6X6X6 GAUGE STEEL MESH) 4" WIDE SOLID WHITE STRIPEA 4" DIAGONAL WHITE STRIPE AT 45° SPACED 2' O.C.B 18" WIDE CONC. CURB & GUTTER (SEE DETAIL)C 18" WIDE REVERSE PITCH CONC. CURB & GUTTER (SEE DETAIL)D 30" WIDE CONC. CURB & GUTTER (SEE DETAIL)E BUILDING DOOR SLAB (2% MAX. SLOPE WITHIN DRIVE IN OR MAN DOOR)F ADA COMPLIANT CURB RAMP (SEE DETAIL)G R7-8 HANDICAP PARKING SIGN WITH BOLLARD (SEE DETAIL)H ADA COMPLIANT STALL INSIGNIA, WHITEI DRIVE-IN-DOOR PARKING COUNT (FOR INFORMATIONAL ONLY, NOT TO BE PAINTED) CONCRETE SIDEWALK (PRIVATE) JDEPRESS & TAPER CURB HEAD. INSTALL NEENAH DETACTABLE WARNING PLATE AT SIDEWALK. KINTEGRAL CURB (SEE DETAIL) ASPHALT PAVEMENT IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS ASPHALT WALK IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS 5"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE) MAN DOOR LBOLLARD (SEE DETAIL) 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH SITE DATA EXISTING SITE AREA: 24.33 AC (1,059,970 S.F.) PASSENGER CAR PARKING: 172 STALLS (8 ADA) TRAILER PARKING: 51 STALLS DOCK STALLS:32 STALLS BUILDING AREAS: 5.87 AC (256,000 S.F) GREENSPACE AREA:12.84 AC (559,553 S.F.) TOTAL IMPERVIOUS AREA:11.47 AC (500,417 S.F.) GREEN SPACE (%)52.78% SOUTH HICKORY STREET (120' PUBLIC R.O.W.) EDGE OF ICE ELEV=700.83 POND PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D 10.0'(TYP) 18.0' (TYP) 10.0'(TYP) 18.0' (TYP) 18.0' (TYP) 10.0'(TYP) 18.0' (TYP) 10.0'(TYP) 24.0' 24.0' 24.0' R20.0' R5.0' (TYP) R5.0' (TYP) R5.0' (TYP) 18.0' (TYP) R50.0' R44.0' 12.0' (TYP) MATCH LINE SEE SHEET C-7 13.5'13.5' 20.0' 10.0' R40.0' R40.0' 106.0' R5.0' (TYP) 24.0' 10.0' TAPER 10.0' TAPER AAB B F F F I I F A 5 52 17 14 13K K JH G J H G E D C D D C D C 166.5' F F F F 35.0' 10.0' 55.0'(TYP) 80.0' L L L 9.2'9.2' E E 10.1' 10.1' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 25.0' REAR BUILDING SETBACK 16.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 20' STORMWATER DRAINAGE EASEMENT PER CSM 9530 AND PER DOC NO. 11346144 5.0' 5.0' 5.0'5.0' 5.0'5.0' 16 15 6.0' 6.0' 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 10.0'(TYP) FFF 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 PROPERTY LINE PROPERTY LINE PROPOSED LIGHT POLE (TYP) CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 BICYCLE PARKING (5) 30.0' 15.0' 6.0' VISION CLEARANCE AREA VISION CLEARANCE AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI SITE DIMENSIONAL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM SITE DIMENSIONAL & PAVING PLAN 1CITY COMMENTS11/09/26C-8 1" = 30' SITE DIMENSIONAL & PAVING PLAN FRANKLIN SIX SIBS # D.I.D LIGHT DUTY PAVEMENT LEGEND 8"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 3-1/2" ASPHALTIC CONC. (2 LIFTS) 1-3/4" BINDER COURSE (4 LT 58-28 S) 1-3/4" SURFACE COURSE (5 LT 58-28 S) HEAVY DUTY PAVEMENT 12"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"ASPHALTIC CONC. (2 LIFTS) 2-1/4" BINDER COURSE (3 MT 58-28 S) 1-3/4" SURFACE COURSE (4 MT 58-28 S) HEAVY DUTY CONCRETE PAVEMENT 6"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 8"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE WITH 6X6X6 GAUGE STEEL MESH) 4" WIDE SOLID WHITE STRIPEA 4" DIAGONAL WHITE STRIPE AT 45° SPACED 2' O.C.B 18" WIDE CONC. CURB & GUTTER (SEE DETAIL)C 18" WIDE REVERSE PITCH CONC. CURB & GUTTER (SEE DETAIL)D 30" WIDE CONC. CURB & GUTTER (SEE DETAIL)E BUILDING DOOR SLAB (2% MAX. SLOPE WITHIN DRIVE IN OR MAN DOOR)F ADA COMPLIANT CURB RAMP (SEE DETAIL)G R7-8 HANDICAP PARKING SIGN WITH BOLLARD (SEE DETAIL)H ADA COMPLIANT STALL INSIGNIA, WHITEI DRIVE-IN-DOOR PARKING COUNT (FOR INFORMATIONAL ONLY, NOT TO BE PAINTED) CONCRETE SIDEWALK (PRIVATE) JDEPRESS & TAPER CURB HEAD. INSTALL NEENAH DETACTABLE WARNING PLATE AT SIDEWALK. KINTEGRAL CURB (SEE DETAIL) ASPHALT PAVEMENT IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS ASPHALT WALK IN PUBLIC R.O.W. MATCH CITY OF FRANKLIN SPECIFICATIONS 5"1-1/4" CRUSHED AGGREGATE BASE COURSE CONFORMING TO GRADATION REQUIREMENTS OF WISDOT STANDARD SPECIFICATIONS SECTIONS 301 AND 305. 4"P.C.C. (4,000 PSI AIR ENTRAINED CONCRETE) MAN DOOR LBOLLARD (SEE DETAIL) 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH SITE DATA EXISTING SITE AREA: 24.33 AC (1,059,970 S.F.) PASSENGER CAR PARKING: 172 STALLS (8 ADA) TRAILER PARKING: 51 STALLS DOCK STALLS:32 STALLS BUILDING AREAS: 5.87 AC (256,000 S.F) GREENSPACE AREA:12.84 AC (559,553 S.F.) TOTAL IMPERVIOUS AREA:11.47 AC (500,417 S.F.) GREEN SPACE (%)52.78% POND PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION FUTURE BUILDING C D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D PROPERTY LINE SOUTH HICKORY STREET (120' PUBLIC R.O.W.) WEST ELM ROAD SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SHEET C-12 RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE SHEET C-10 SHEET C-11 141,812 S.F. OFDISTURBED AREA 141,812 S.F. OFDISTURBED AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI GRADING PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM GRADING PLAN OVERVIEW 1CITY COMMENTS11/09/26C-9 1" = 80' GRADING PLAN OVERVIEW FRANKLIN SIX SIBS 1" = 80' 0160' GRAPHICAL SCALE (FEET) NORTH CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 ALL GRADING SHALL MEET ADA REQUIREMENTS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL SURFACE FLOW DIRECTION INDICATOR 750.00 GRASSPAVEMENT SPOT ELEVATION CLEANOUT 101 100 101 100 724 721 720 719 718 717 716 715 715 715 715 TREELINE 715 717 716718 721 713 714 713 714 712 713 711 PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D PROPERTY LINE SOUTH HICKORY STREET (120' PUBLIC R.O.W.) MATCH LINE SEE SHEET C-11 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 10.0' SIDE BUILDING SETBACK 25.0' REAR BUILDING SETBACK RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE 712.70 713.34 713.84 712.70712.70712.70712.70712.70 713.38 713.05 712.70 712.70 712.70 712.70 712.70 712.70 713.43 713.73 715.00 713.05 RIM 715.00 717.30 717.30 713.85 RIM 714.66715.78 715.58 715.38 RIM 716.39 716.44 716.51 716.64 715.46 RIM 716.63 EP 716.44 716.51 716.36 716.20 717.30 716.20 717.30 716.63 716.44 716.24 716.44 716.63 715.32 RIM 716.64 716.44 716.37 716.44 716.64 716.44 716.36 716.44 716.63 EP716.63 EP 716.63 EP 716.44 716.36 716.44 716.63 EP 717.21717.21 717.30 717.21717.21 717.30 717.21717.21 717.30 715.59 RIM 717.21717.21 717.30 716.64 716.55 717.03 717.79 721.52 EX 719.54 713.01 713.28713.64 714.89 EX 714.13 717.13 717.00 717.15 718.69 719.64 EX 717.61 711.70 RIM 717.30 717.30 714.24 711.70 RIM 711.71 RIM 714.20 RIM 716.20 713.56 716.79 EX 716.96 EX 716.78 EX 716.60 EX 717.49 EX 717.46 EX 717.59 EX717.61 EX 717.29 713.33 717.30 717.20 714.55 714.65 713.36 717.20 717.20 717.30 712.70 717.20 714.30 714.62 713.30 717.29 717.20 717.20 717.30 717.31 717.30 713.30 712.70 717.20 717.20 717.30 717.30 717.30 713.30 713.30 717.30 717.20 714.34 714.65 713.38 713.31 714.34 717.20 717.30 717.30 713.30 713.30 717.30 717.30 717.14 717.20 717.30 716.63 EP 718.32 EX 718.10 EX 718.57 EX 718.35 EX 719.26 EX 719.24 EX 719.01 EX719.01 EX 716.36 716.96 716.65 EP 716.36716.36 717.13 TW 716.24 717.21 712.29 712.29 713.13 714.43 712.70 714.13 714.40 717.28 EX717.33 EX 719.13 722.86 EX722.65 EX 720.16 EX 720.14 EX 717.20 717.20 717.20 717.20 713.79 712.70 712.44712.96 713.41713.78 715.64 EX 715.65 EX 713.60 715.16 715.50 715.98 EX 717.28 716.20 716.36 718.40 716.63 EP716.63 EP 716.36 716.91 716.34 715.50 719.90 EX 719.81 EX 717.53 717.26 719.52 719.27 714.60 714 715 715 714 715 717 717 716 717 716 716 716 716 716 716 718 719 721 717718 719720721722 718 719 720 718 719 718 718 719 716717 718 719 717 716 715 717 716 715 714 713714715716717 717 716 715 714 713 713713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 715 716 717 713 714 715 717 716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717714 713 717 717 717 717 717 717 717 714 713 715.00 716 717 716 716.63 EP 717.13 TW717.13 TW717.13 TW717.13 TW717.13 TW717.13 TW 716 723 717.13 TW 721 722 718.06 718.00 717.51 PROPERTY LINE PROPERTY LINE VISION CLEARANCE AREA VISION CLEARANCE AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI GRADING PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM GRADING PLAN 1CITY COMMENTS11/09/26C-10 1" = 30' GRADING PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 ALL GRADING SHALL MEET ADA REQUIREMENTS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL SURFACE FLOW DIRECTION INDICATOR 750.00 GRASSPAVEMENT SPOT ELEVATION CLEANOUT 101 100 101 100 RIPRAP 714 713 712 710 705 705 705 705 705 704 703 702 714 TREELINE TREELINE 715 715 715 715 717 716715 714 703705 707710 EDGE OF ICE ELEV=700.83 POND 712 709 708 707 706 704705 702703 701 711 710 709 708 707 706 705705 711 712 712 713 714 713 713 717 715 706 707 708708 707 708 706 704 703 702 701 716 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D SOUTH HICKORY STREET (120' PUBLIC R.O.W.) 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 25.0' REAR BUILDING SETBACK 16.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 20' STORMWATER DRAINAGE EASEMENT PER CSM 9530 AND PER DOC NO. 11346144 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 MATCH LINE SEE SHEET C-12 RIDGE LINE RIDGE LINE 714 713 716 717 713 717 717 717 715 714 713 712 711 711 712 713 716 715 714 713 712 716 717 717 716 715 714 713 712 716 717 717 716 715 714 713 712 716 716 716 717 716 715 716 717 717 712 711.54 RIM 711.57 713.12 714.67 716.63 EP 716.44 716.36 716.36 716.28 716.08 715.33 RIM 716.28 716.24 716.36 716.08716.63 716.43 716.36 716.43 716.63 717.30 717.30 717.21 717.21 716.63 EP 716.49 716.42 716.68 716.43 716.63 716.63 EP 716.44 716.36 716.44 716.63 EP 716.63 EP 716.44 716.36 716.44 716.63 EP 715.45 RIM 715.20 RIM 716.00 715.66 714.98 713.90 717.30 717.21 717.21 717.21717.21 717.30 717.21717.21 717.30 717.30 715.00 712.29 RIM 716.51 716.06 715.87 715.12 716.63 EP 714.00 EX 713.67 EX 713.61 EX 713.96 EX 714.64 EX 714.63 EX 714.63 EX 714.60 EX 714.63 EX 715.42 EX 716.36716.36 716.63 EP 716.36 716.36 716.63 EP 715.67 716.36 715.00 716.32 EX716.29 EX 715.41 715.41 EX 715.47 EX 715.93 716.24 716.16 715.41 715.41 715.51 715.37 717 716 717 717 717 704 705 706 707 708 709 710 711 712 713 714 715 715 716 717 716.03 716.21 716.78 716.66 711 710 709 712 713 714 PROPERTY LINE PROPERTY LINE MATCH LINE SEE SHEET C-10 VISION CLEARANCE AREA VISION CLEARANCE AREA CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 141,812 S.F. OFDISTURBED AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI GRADING PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM GRADING PLAN 1CITY COMMENTS11/09/26C-11 1" = 30' GRADING PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 ALL GRADING SHALL MEET ADA REQUIREMENTS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL SURFACE FLOW DIRECTION INDICATOR 750.00 GRASSPAVEMENT SPOT ELEVATION CLEANOUT 101 100 101 100 RIPRAP RIPRAP 705 705 705 705 704 703 702 701 700 699 714 713 710 708 707 705 715 715 TREELINE 715 715 717 714 718718 717 716 697 699 698 703 700 705 708 710 712 715 POND 712 709 708 707 711 708 708 706 707 704 702703 701 714 713 713 717 715 706 707 708708 707 708 706 704 703 702 701 716 704 703 702 701 699 FUTURE BUILDING C WETLANDS PER CSM 9530 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 25.0' REAR BUILDING SETBACK 10.0' SIDE BUILDING SETBACK STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) 717 716 715715 716 717 715 716 717 717 716 715 711 705 706 707 708 714 710 706 714 710 706 711 710 709 712 713 714 PROPERTY LINE PROPERTY LINE PROPERTY LINE MATCH LINE SEE SHEET C-11 CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 141,812 S.F. OF DISTURBED AREA 141,812 S.F. OFDISTURBED AREA 30.0' FRONT BUILDING SETBACK DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI GRADING PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM GRADING PLAN 1CITY COMMENTS11/09/26C-12 1" = 30' GRADING PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 ALL GRADING SHALL MEET ADA REQUIREMENTS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL SURFACE FLOW DIRECTION INDICATOR 750.00 GRASSPAVEMENT SPOT ELEVATION CLEANOUT 101 100 101 100 DD DD D ((R) S88°36'13"W CSM 9260) POND PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION FUTURE BUILDING C D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D MATCH LINE SEE SHEET C-15 SHEET C-16 SHEET C-15 PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE SOUTH HICKORY STREET (120' PUBLIC R.O.W.) WEST ELM ROAD SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SOUTH HICKORY STREET (120' PUBLIC R.O.W.) SHEET C-14 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EROSION CONTROL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EROSION CONTROL PLAN OVERVIEW 1CITY COMMENTS11/09/26C-13 1" = 80' EROSION CONTROL PLAN OVERVIEW FRANKLIN SIX SIBS 1" = 80' 0160' GRAPHICAL SCALE (FEET) NORTH 1. INSTALL PERIMETER SILT FENCE, INLET PROTECTION AND TEMPORARY CONSTRUCTION ENTRANCE. 2. STRIP AND STOCKPILE TOPSOIL, INSTALL SILT FENCE AROUND PERIMETER OF STOCKPILE. 3. CONDUCT ROUGH GRADING EFFORTS AND INSTALL CHECK DAMS AND SEDIMENT TRAPS/BASINS AS NEEDED. 4. INSTALL UTILITY PIPING AND STRUCTURES, IMMEDIATELY INSTALL INLET PROTECTION. 5. COMPLETE FINAL GRADING, INSTALLATION OF GRAVEL BASE COURSES, PLACEMENT OF CURBS, PAVEMENTS, WALKS, ETC. 6. PLACE TOPSOIL AND IMMEDIATELY STABILIZE DISTURBED AREAS WITH EROSION CONTROLS. 7. EROSION CONTROL MEASURES SHALL BE REMOVED ONLY AFTER SITE CONSTRUCTION IS COMPLETE WITH ALL SOIL SURFACES HAVING AN ESTABLISHED VEGETATIVE COVER. CONTRACTOR MAY MODIFY SEQUENCING AFTER ITEM 1 AS NEEDED TO COMPLETE CONSTRUCTION IF EROSION CONTROLS ARE MAINTAINED IN ACCORDANCE WITH THE CONSTRUCTION SITE EROSION CONTROL REQUIREMENTS. CONSTRUCTION SITE SEQUENCING LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL CLEANOUT LIMITS OF DISTURBANCE SILT FENCE 101 100 101 100 DIVERSION BERM DIVERSION CHANNEL / SWALE CULVERT PIPE DITCH CHECKDITCH CHECKINLET PROTECTION CONSTRUCTION ENTRANCE (STONE TRACKING PAD) EROSION CONTROL BLANKET (DOT CLASS I, TYPE B) CHANNEL EROSION CONTROL BLANKET (DOT CLASS II, TYPE C) POND SPILLWAY MATTING (SEE POND DETAILS) RIP RAP OUTLET PROTECTION FOR END APRON NOTE: REMAINING DISTURBED AREAS OF SLOPES 5:1 OR FLATTER TO BE HYDRSEEDED CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 724 721 720 719 718 717 716 715 715 715 715 717 716718 721 713 714 713 714 712 713 711 PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D MATCH LINE SEE SHEET C-15 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 10.0' SIDE BUILDING SETBACK 25.0' REAR BUILDING SETBACK DITCH CHECK (TYP) (SEEDETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) SILT FENCE (TYP) (SEE DETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) 30.0' FRONT BUILDING SETBACK PROPERTY LINE PROPERTY LINE PROPERTY LINE 605,063 S.F. OF DISTURBED AREA 605,063 S.F. OF DISTURBED AREA 605,063 S.F. OF DISTURBED AREA RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE RIDGE LINE 714 715 715 714 715 717 717 716 717 716 716 716 716 716 716 718 719 721 717718 719720721722 718 719 720 718 719 718 718 719 716717 718 719 717 716 715 717 716 715 714 713714715716717 717 716 715 714 713 713 713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 715 716 717 713 714 715 717716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717714 713 717 717 717 717 717 717 717 714 713 716 717 716 716 723 721 722 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) VISION CLEARANCE AREA VISION CLEARANCE AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EROSION CONTROL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EROSION CONTROL PLAN 1CITY COMMENTS11/09/26C-14 1" = 30' EROSION CONTROL PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH 1. INSTALL PERIMETER SILT FENCE, INLET PROTECTION AND TEMPORARY CONSTRUCTION ENTRANCE. 2. STRIP AND STOCKPILE TOPSOIL, INSTALL SILT FENCE AROUND PERIMETER OF STOCKPILE. 3. CONDUCT ROUGH GRADING EFFORTS AND INSTALL CHECK DAMS AND SEDIMENT TRAPS/BASINS AS NEEDED. 4. INSTALL UTILITY PIPING AND STRUCTURES, IMMEDIATELY INSTALL INLET PROTECTION. 5. COMPLETE FINAL GRADING, INSTALLATION OF GRAVEL BASE COURSES, PLACEMENT OF CURBS, PAVEMENTS, WALKS, ETC. 6. PLACE TOPSOIL AND IMMEDIATELY STABILIZE DISTURBED AREAS WITH EROSION CONTROLS. 7. EROSION CONTROL MEASURES SHALL BE REMOVED ONLY AFTER SITE CONSTRUCTION IS COMPLETE WITH ALL SOIL SURFACES HAVING AN ESTABLISHED VEGETATIVE COVER. CONTRACTOR MAY MODIFY SEQUENCING AFTER ITEM 1 AS NEEDED TO COMPLETE CONSTRUCTION IF EROSION CONTROLS ARE MAINTAINED IN ACCORDANCE WITH THE CONSTRUCTION SITE EROSION CONTROL REQUIREMENTS. CONSTRUCTION SITE SEQUENCING LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL CLEANOUT LIMITS OF DISTURBANCE SILT FENCE 101 100 101 100 DIVERSION BERM DIVERSION CHANNEL / SWALE CULVERT PIPE DITCH CHECKDITCH CHECKINLET PROTECTION CONSTRUCTION ENTRANCE (STONE TRACKING PAD) EROSION CONTROL BLANKET (DOT CLASS I, TYPE B) CHANNEL EROSION CONTROL BLANKET (DOT CLASS II, TYPE C) POND SPILLWAY MATTING (SEE POND DETAILS) RIP RAP OUTLET PROTECTION FOR END APRON NOTE: REMAINING DISTURBED AREAS OF SLOPES 5:1 OR FLATTER TO BE HYDRSEEDED CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 714 713 712 710 705 705 705 705 705 704 703 702 714 DD 715 715 715 717 716715 714 703705 707710 POND 709 708 707 706 704705 702703 701 711 710 709 708 707 706 705705 713 711 712 713 714 713 713 717 715 706 707 708708 707 708 706 704 703 702 701 716 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D 30.0' FRONT BUILDING SETBACK 25.0' REAR BUILDING SETBACK 16.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 20' STORMWATER DRAINAGE EASEMENT PER CSM 9530 AND PER DOC NO. 11346144 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 MATCH LINE SEE SHEET C-16 RIP RAP (TYP) (SEEDETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEEDETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEEDETAIL ON SHEET C-20) SILT FENCE (TYP) (SEE DETAIL ON SHEET C-20) SILT FENCE (TYP)(SEE DETAIL ON SHEET C-20) CONSTRUCTION ENTRANCE (SEE DETAIL ON SHEET C-20) INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 PROPERTY LINE PROPERTY LINE 605,063 S.F. OF DISTURBED AREA 141,812 S.F. OFDISTURBED AREA 605,063 S.F. OF DISTURBED AREA RIDGE LINE RIDGE LINE 714 713 716 717 713 717 717 717 717 717 715 714 713 712 711 711 712 713 716 715 714 713 712 716 717 717 716 715 714 713 712 716 717 717 716 715 714 713 712 716 716 716 717 716 715 716 717 717 712 717 716 717 717 717 704 705 706 707 708 709 710 711 712 713 714 715 715 716 717 711 710 709 712 713 714 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) MATCH LINE SEE SHEET C-14 VISION CLEARANCE AREA VISION CLEARANCE AREA CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EROSION CONTROL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EROSION CONTROL PLAN 1CITY COMMENTS11/09/26C-15 1" = 30' EROSION CONTROL PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH 1. INSTALL PERIMETER SILT FENCE, INLET PROTECTION AND TEMPORARY CONSTRUCTION ENTRANCE. 2. STRIP AND STOCKPILE TOPSOIL, INSTALL SILT FENCE AROUND PERIMETER OF STOCKPILE. 3. CONDUCT ROUGH GRADING EFFORTS AND INSTALL CHECK DAMS AND SEDIMENT TRAPS/BASINS AS NEEDED. 4. INSTALL UTILITY PIPING AND STRUCTURES, IMMEDIATELY INSTALL INLET PROTECTION. 5. COMPLETE FINAL GRADING, INSTALLATION OF GRAVEL BASE COURSES, PLACEMENT OF CURBS, PAVEMENTS, WALKS, ETC. 6. PLACE TOPSOIL AND IMMEDIATELY STABILIZE DISTURBED AREAS WITH EROSION CONTROLS. 7. EROSION CONTROL MEASURES SHALL BE REMOVED ONLY AFTER SITE CONSTRUCTION IS COMPLETE WITH ALL SOIL SURFACES HAVING AN ESTABLISHED VEGETATIVE COVER. CONTRACTOR MAY MODIFY SEQUENCING AFTER ITEM 1 AS NEEDED TO COMPLETE CONSTRUCTION IF EROSION CONTROLS ARE MAINTAINED IN ACCORDANCE WITH THE CONSTRUCTION SITE EROSION CONTROL REQUIREMENTS. CONSTRUCTION SITE SEQUENCING LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL CLEANOUT LIMITS OF DISTURBANCE SILT FENCE 101 100 101 100 DIVERSION BERM DIVERSION CHANNEL / SWALE CULVERT PIPE DITCH CHECKDITCH CHECKINLET PROTECTION CONSTRUCTION ENTRANCE (STONE TRACKING PAD) EROSION CONTROL BLANKET (DOT CLASS I, TYPE B) CHANNEL EROSION CONTROL BLANKET (DOT CLASS II, TYPE C) POND SPILLWAY MATTING (SEE POND DETAILS) RIP RAP OUTLET PROTECTION FOR END APRON NOTE: REMAINING DISTURBED AREAS OF SLOPES 5:1 OR FLATTER TO BE HYDRSEEDED CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 705 705 705 705 704 703 702 701 700 699 714 713 710 708 707 705 715 715 DD 715 715 717 714 718718 717 716 D 697 699 698 703 700 705 708 710 712 715 POND 712 709 708 707 711 708 708 706 707 704 702703 701 714 713 713 717 715 706 707 708708 707 708 706 704 703 702 701 716 704 703 702 701 699 FUTURE BUILDING C 30' WETLAND BUFFER PER MATCH LINE SEE SHEET C-15 WETLANDS PER CSM 9530 STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 INLET PROTECTION (TYP) (SEE DETAIL ON SHEET C-20) 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 25.0' REAR BUILDING SETBACK 10.0' SIDE BUILDING SETBACK SILT FENCE (TYP) (SEE DETAIL ON SHEET C-20) PROPERTY LINE PROPERTY LINE PROPERTY LINE 141,812 S.F. OFDISTURBED AREA SILT FENCE (TYP) (SEE DETAIL ON SHEET C-20) 30.0' FRONT BUILDING SETBACK 717 716 715715 716 717 715 716 717 717 716 715 711 705 706 707 708 714 710 706 714 710 706 711 710 709 712 713 714 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI EROSION CONTROL PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM EROSION CONTROL PLAN 1CITY COMMENTS11/09/26C-16 1" = 30' EROSION CONTROL PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH 1. INSTALL PERIMETER SILT FENCE, INLET PROTECTION AND TEMPORARY CONSTRUCTION ENTRANCE. 2. STRIP AND STOCKPILE TOPSOIL, INSTALL SILT FENCE AROUND PERIMETER OF STOCKPILE. 3. CONDUCT ROUGH GRADING EFFORTS AND INSTALL CHECK DAMS AND SEDIMENT TRAPS/BASINS AS NEEDED. 4. INSTALL UTILITY PIPING AND STRUCTURES, IMMEDIATELY INSTALL INLET PROTECTION. 5. COMPLETE FINAL GRADING, INSTALLATION OF GRAVEL BASE COURSES, PLACEMENT OF CURBS, PAVEMENTS, WALKS, ETC. 6. PLACE TOPSOIL AND IMMEDIATELY STABILIZE DISTURBED AREAS WITH EROSION CONTROLS. 7. EROSION CONTROL MEASURES SHALL BE REMOVED ONLY AFTER SITE CONSTRUCTION IS COMPLETE WITH ALL SOIL SURFACES HAVING AN ESTABLISHED VEGETATIVE COVER. CONTRACTOR MAY MODIFY SEQUENCING AFTER ITEM 1 AS NEEDED TO COMPLETE CONSTRUCTION IF EROSION CONTROLS ARE MAINTAINED IN ACCORDANCE WITH THE CONSTRUCTION SITE EROSION CONTROL REQUIREMENTS. CONSTRUCTION SITE SEQUENCING LEGEND STORM SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON EXISTING 1' CONTOUR INTERVAL EXISTING 5' CONTOUR INTERVAL PROPOSED 1' CONTOUR INTERVAL PROPOSED 5' CONTOUR INTERVAL CLEANOUT LIMITS OF DISTURBANCE SILT FENCE 101 100 101 100 DIVERSION BERM DIVERSION CHANNEL / SWALE CULVERT PIPE DITCH CHECKDITCH CHECKINLET PROTECTION CONSTRUCTION ENTRANCE (STONE TRACKING PAD) EROSION CONTROL BLANKET (DOT CLASS I, TYPE B) CHANNEL EROSION CONTROL BLANKET (DOT CLASS II, TYPE C) POND SPILLWAY MATTING (SEE POND DETAILS) RIP RAP OUTLET PROTECTION FOR END APRON NOTE: REMAINING DISTURBED AREAS OF SLOPES 5:1 OR FLATTER TO BE HYDRSEEDED CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL CONSTRUCTION NOTES LOCATED ON SHEET C-2 E E E S S S S DD S DD POND PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D PROPERTY LINE PROPERTY LINE SHEET C-18 SHEET C-19 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) WEST ELM ROAD SOUTH HICKORY STREET (120' PUBLIC R.O.W.) PROPERTY LINE PROPERTY LINE PROPERTY LINE DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI UTILITY PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM UTILITY PLAN OVERVIEW 1CITY COMMENTS11/09/26C-17 1" = 60' UTILITY PLAN OVERVIEW FRANKLIN SIX SIBS 1" = 60' 0120' GRAPHICAL SCALE (FEET) NORTH CONSTRUCTION NOTES LOCATED ON SHEET C-2 CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL LEGEND SANITARY SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON CLEANOUT VALVE BOX FIRE HYDRANT PROPOSED COMBINED SEWER STORM SEWER MANHOLE PROPOSED DRAIN TILE PROPOSED ELECTRIC PROPOSED FIBER OPTIC PROPOSED FIRE PROTECTION PROPOSED GAS PROPOSED SANITARY SEWER PROPOSED SANITARY FORCEMAIN PROPOSED INLET DRAIN TILE (DRAIN TILE DONUT, SEE DETAIL) PROPOSED STORM SEWER PROPOSED TELEPHONE PROPOSED WATERMAINW LIGHT POLE ELECTRIC TRANSFORMER UTILITY CROSSING E E S SANITARY MANHOLE RIM=717.03 12" N=692.09 12" S=691.88 CONCRETE CURB 15" CULVERT INV=715.00 15" CULVERT INV=712.88 4" INV=712.03 4" INV=714.15 4" INV=716.69 CURB INLET RIM=715.57 12" N=713.17 CURB INLET RIM=715.50 12" S=713.10 12' E=713.00 CURB INLET RIM=715.50 12" W=713.00 12" S=713.10 15" SE=713.00 CURB INLET RIM=715.64 12" N=713.24 CURB INLET RIM=717.38 12" E=714.98 12" S=715.08 CURB INLET RIM=717.49 12" N=715.29 CURB INLET RIM=717.53 12" N=715.18 CURB INLET RIM=717.42 12" S=714.92 15" E=714.92 12' W=714.92 CURB INLET RIM=719.66 12" N=716.46 12" E=716.41 CURB INLET RIM=719.47 12" S=714.77CURB INLET RIM=719.68 12" W=716.08 15" NE=715.98 CONCRETE STORM STRUCTURE RIM=715.30 6" NE=710.75 4" S=712.35 7" WEEP=714.37 CONCRETE STORM STRUCTURE RIM=717.09 6" N=712.19 4" S=713.99 5" WEEP= 715.91 15" CULVERT INV=715.89 PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D W W MATCH LINE SEE SHEET C-19 PROPOSED FDC PROPOSED FDC CONTRACTOR TO CONNECT TO EX. PUBLIC SAN, SWR. W/ DROP TEE CONNECTION APPROX. 13.6' DROP INV=705.54 (6" W)PR. INV=±691.58(12"N/S) EX. CONTRACTOR TO NOTIFY CITY OF FRANKLIN WAT./SWR. DEPT. 72 HOURS PRIOR TO CONNECTION. CONTRACTOR TO FIELD VERIFY EX. INV AND NOTIFY ENGINEER OF ANY DISCREPANCIES SALVAGE EXISTING CASTINGS & RETURN TO THE CITY OF FRANKLIN. REPLACE FRAME WITH NEENAH R-3067-C, TYPE C GRATE CONNECT EXISTING MAIN W/ 6" TEE CONTRACTOR TO FIELD VERIFY EX. INV AND LOCATION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR TO ENSURE 6' OF COVER. CONNECT EXISTING MAIN W/ 6" TEE CONTRACTOR TO FIELD VERIFY EX. INV AND LOCATION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR TO ENSURE 6' OF COVER B.C 50.0 B.C 50.1 6" C-900 PVC FIRE PROTECTION LINE 6" C-900 PVC FIRE PROTECTION LINE BY OTHERS 6" C-900 PVC FIRE PROTECTION LINE 6" C-900 PVC FIRE PROTECTION LINE 6" C-900 PVC FIRE PROTECTION LINE HYRDRANT ASSEMBLY (TYP) HYRDRANT ASSEMBLY (TYP) HYRDRANT ASSEMBLY (TYP) HYRDRANT ASSEMBLY (TYP) HYRDRANT ASSEMBLY (TYP) PROPOSED HYDRANT ASSEMBLY (TYP) GROUND = 721.80 NOZZLE = 723.30 CONNECT TO EXISTING HYDRANT LEAD W/ 6" ELBOW. CONTRACTOR TO FIELD VERIFY LOCATION AND NOTIFY ENGINEER OF ANY DISCREPANCIES 41.7 L.F. 6" C-900 PVC (6' MIN. COVER) INSERTA TEE 23.2 INV=709.96 (24" SE) INV=709.96 (24" NW) INV=710.63 (8" NE) 45° BEND 25.2 INV=708.74 (10" SE) INV=708.74 (10" W) STM MH 35.0 36" DIA RIM= 713.10 INV=708.59 (12" S) INV=708.11 (10" E) INV=707.74 (15" N) BC 20.0 INV=713.00 (10") BC 22.0 INV=713.00 (10") BC 21.0 INV=713.00 (8") BC 23.0 INV=713.00 (8") BC 27.0 INV=713.13 (8")45° BEND 27.1 INV=713.08 (8" W) INV=713.08 (8" NE) INL 4.0 48" DIA RIM= 715.38 INV=710.31 (24" E) INV=710.31 (24" NW) 45° BEND 23.1 INV=712.67 (8" SW) INV=712.67 (8" E) 45° BEND 27.2 INV=712.99 (8" SW) INV=712.99 (8" N) INL 1.0 48" DIA RIM= 715.59 INV=712.53 (10" N) INV=711.90 (18" W) INL 2.0 48" DIA RIM= 715.32 INV=712.06 (8" N) INV=711.59 (18" E) INV=711.59 (18" W) INL 3.0 48" DIA RIM= 715.46 INV=712.06 (10" N) INV=710.74 (18" E) INV=710.74 (24" W) INL 5.0 48" DIA RIM= 714.10 INV=709.36 (24" SE) INV=709.36 (24" N) BC 25.0 INV=708.97 (10") BC 29.0 INV=708.97 (10") INL 6.0 60" DIA RIM= 713.05 INV=708.08 (24" S) INV=705.32 (36" E) INV=705.32 (42" N) 45° BEND 27.3 INV=711.09 (8" S) INV=711.09 (8" NW) BC 26.0 INV=709.00 (12") BC 24.0 INV=708.80 (12") BC 28.0 INV=708.80 (12") BC 30.0 INV=708.74 (12") INL 13.0 72" DIA RIM= 711.71 INV=706.91 (24" E) INV=707.11 (15" NE) INV=706.91 (30" W) INL 14.0 60" DIA RIM= 711.70 INV=707.89 (12" N) INV=707.02 (15" S) INV=706.44 (30" E) INV=706.44 (36" W) B.C 36.0 INV=705.83 (6") SAMPLING SAN MH 37.0 48" DIA RIM= 718.87 INV=705.54 (6" W) INV=705.83 (6" E) 45° BEND 25.1 INV=708.82 (10" S) INV=708.82 (10" NW) 45° BEND 26.1 INV=708.65 (12" N) INV=708.65 (12" SW) 45° BEND 26.2 INV=708.57 (12" NE) INV=708.57 (12" W) STM MH 36.0 36" DIA RIM= 713.10 INV=708.76 (10" N) INV=707.94 (12" E) INV=707.94 (15" SW) INL 12.0 60" DIA RIM= 711.70 INV=708.63 (10" SE) INV=707.93 (12" S) INV=707.50 (24" W)INL 10.0 48" DIA RIM= 714.20 INV=710.90 (8" SE) INV=710.90 (10" NW) 142.5 L.F. 18" RCP @ S=0.60% 142.2 L.F. 24" HDPE @ S=0.30% 87.6 L.F. 24" RCP @ S=0.40% 159.5 L.F. 24" HDPE @ S=0.80% 152.8 L.F. 42" HDPE @ S=0.45% 18.2 L.F. 8" SCH-40 PVC @ S=1.04% 117.3 L.F. 30" HDPE @ S=0.40% 279.9 L.F. 36" HDPE @ S=0.40% 45.1 L.F. 10" SCH-40 PVC @ S=2.08% 45.1 L.F. 8" SCH-40 PVC @ S=2.08% 45.0 L.F. 10" SCH-40 PVC @ S=1.04% 20.0 L.F. 12" SCH-40 PVC @ S=1.05%14.0 L.F. 10" SCH-40 PVC @ S=1.04% 102.5 L.F. 12" SCH-40 PVC @ S=1.04% 4.8 L.F. 8" SCH-40 PVC @ S=1.04% 8.4 L.F. 8" SCH-40 PVC @ S=1.04% 183.0 L.F. 8" SCH-40 PVC @ S=1.04% 102.5 L.F. 12" SCH-40 PVC @ S=0.83% 20.0 L.F. 10" SCH-40 PVC @ S=1.05%14.0 L.F. 12" SCH-40 PVC @ S=1.04% 12.0 L.F. 8" SCH-40 PVC @ S=2.76% 73.7 L.F. 8" SCH-40 PVC @ S=2.77% 28.3 L.F. 6" SDR-35 PVC @ S=1.04% 34.9 L.F. 6" SDR-35 PVC @ S=1.04% 153.6 L.F. 18" RCP @ S=0.20% 149.6 L.F. 24" RCP @ S=0.40% 117.3 L.F. 24" HDPE @ S=0.50% 82.5 L.F. 15" HDPE @ S=0.87% 8.5 L.F. 10" SCH-40 PVC @ S=1.04% 59.9 L.F. 10" SCH-40 PVC @ S=1.04% 8.5 L.F. 12" SCH-40 PVC @ S=1.04% 60.0 L.F. 12" HDPE @ S=1.04% 97.1 L.F. 15" HDPE @ S=0.85% 142.1 L.F. 10" HDPE @ S=1.60% 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 10.0' SIDE BUILDING SETBACK 25.0' REAR BUILDING SETBACK SOUTH HICKORY STREET (120' PUBLIC R.O.W.) PROPERTY LINE PROPERTY LINE SALVAGE EXISTING CASTINGS & RETURN TO THE CITY OF FRANKLIN. REPLACE FRAME WITH NEENAH R-3067-C, TYPE C GRATE DRAINTILE (TYP) VISION CLEARANCE AREA VISION CLEARANCE AREA DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI UTILITY PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM UTILITY PLAN 1CITY COMMENTS11/09/26C-18 1" = 30' UTILITY PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH CONSTRUCTION NOTES LOCATED ON SHEET C-2 CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL LEGEND SANITARY SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON CLEANOUT VALVE BOX FIRE HYDRANT PROPOSED COMBINED SEWER STORM SEWER MANHOLE PROPOSED DRAIN TILE PROPOSED ELECTRIC PROPOSED FIBER OPTIC PROPOSED FIRE PROTECTION PROPOSED GAS PROPOSED SANITARY SEWER PROPOSED SANITARY FORCEMAIN PROPOSED INLET DRAIN TILE (DRAIN TILE DONUT, SEE DETAIL) PROPOSED STORM SEWER PROPOSED TELEPHONE PROPOSED WATERMAINW LIGHT POLE ELECTRIC TRANSFORMER UTILITY CROSSING E E CONCRETE CURB S S DD S DD SANITARY MANHOLE RIM=716.54 12" N=694.24 12" S=694.10 SANITARY MANHOLE RIM=713.82 12" N=693.07 12" S=693.07 10" W=695.89 POND SANITARY MANHOLE RIM=714.74 12" N=693.49 12" S=693.49 15" CULVERT INV=710.94 30" CULVERT INV=708.26 15" CULVERT INV=712.66 15" CULVERT INV=713.33 4" INV=714.85 4" INV=713.80 4" INV=712.56 6" INV (BURIED)=709.24 CURB INLET RIM=716.27 12" E=713.72 CURB INLET RIM=716.40 12" W=713.55 15" E=713.55 12" N=713.70 CURB INLET RIM=716.48 12" S=713.93 CURB INLET RIM=715.41 12" E=712.86 CURB INLET RIM=715.34 12" W=712.59 15" E=712.59 CURB INLET RIM=714.20 12" S=711.85 CURB INLET RIM=714.08 12" N=711.83 12' E=711.63 CURB INLET RIM=714.08 12" W=711.63 12' N=711.63 15" NE= 711.63 CURB INLET RIM=713.36 12" E=710.86 CURB INLET RIM=713.44 12" W=710.84 15" E=710.84 STORM MANHOLE RIM=708.65 21" SE=700.63 TOP OF WEIR WALL=705.79 STORM MANHOLE RIM=709.60 30" N=705.02 30" E=705.02 STORM MANHOLE RIM=715.92 30" S=707.05 30" W=706.98 CONCRETE STORM STRUCTURE RIM=716.99 8" S=710.69 4" N=714.54 7" WEEP=716.14 CONCRETE STORM STRUCTURE RIM=716.79 8" N=710.44 4" N=713.24 15" S=710.29 7" WEEP=715.22 CONCRETE STORM STRUCTURE RIM=714.52 4" NW=712.02 15" N=709.52 15" S=709.52 5" WEEP=714.06 CONCRETE STORM STRUCTURE RIM=713.00 4" S=709.70 15" N=709.10 5" WEEP=712.25 30" CULVERT INV=705.01 21" CULVERT INV=700.81 CURB INLET RIM=714.16 12" S=711.71 STORM MANHOLE RIM=708.65 21" NW=700.51 TOP OF WEIR WALL=705.79 CONCRETE STORM STRUCTURE RIM=714.10 4" NW=710.90 15" N=708.70 15" S=708.70 6" WEEP=713.33 15" INV=711.57 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D STM MH 32.1 INV=708.73 (18" E) INV=708.73 (18" NW) INV=712.06 (10" S) OUTSIDE DROP SAN MH 40.0 48" DIA RIM= 716.56 INV=705.55 (6" W) INV=696.32 (10" E) EXISTING W 149.3 L.F. 42" HDPE @ S=0.45% 187.6 L.F. 42" HDPE @ S=0.62% 53.8 L.F. 10" HDPE @ S=0.80% 153.7 L.F. 18" HDPE @ S=0.70% 7.6 L.F. 8" SCH-40 PVC @ S=1.04% 8.5 L.F. 8" SCH-40 PVC @ S=1.04% 100.9 L.F. 8" SCH-40 PVC @ S=1.04% 45.0 L.F. 8" SCH-40 PVC @ S=2.08% 45.0 L.F. 10" SCH-40 PVC @ S=2.08% 38.6 L.F. 8" SCH-40 PVC @ S=3.00% 117.3 L.F. 8" SCH-40 PVC @ S=3.00% MATCH LINE SEE SHEET C-18 PROPERTY LINE 10.0 L.F. 6" SDR-35 PVC @ S=1.04% BC 32.0 INV=713.00 (10") BC 34.0 INV=713.00 (10") BC 33.0 INV=713.00 (8") BC 31.0 INV=713.18 (8") BC 35 INV=713.22 (8") 45° BEND 35.1 INV=713.14 (8" W) INV=713.14 (8" NE) STM MH 35.3 INV=712.00 (8" S) INV=712.00 (10" NW) INL 17.0 48" DIA RIM= 715.20 INV=709.81 (15" E) INV=712.06 (8" S) INV=709.81 (18" W) INL 18.0 48" DIA RIM= 715.33 INV=708.35 (18" SE) INV=708.35 (18" N) 22.5° BEND 36.1 INV=712.02 (8" W) INV=712.02 (8" E) INL 7.0 60" DIA RIM= 712.29 INV=704.63 (42" S) INV=704.63 (42" N) INL 8.0 72" DIA RIM= 711.54 INV=703.96 (42" S) INV=703.96 (42" N) INV=708.50 (8" E) FES 19.0 INV=708.00 (18") FES 9.0 INV=702.81 (42") B.C 38.0 INV=705.75 (6") 10.0 L.F. 6" SDR-35 PVC @ S=1.04% SAMPLING SAN MH 39.0 48" DIA RIM= 717.06 INV=705.65 (6" W) INV=705.65 (6" E) 6" C-900 PVC FIRE PROTECTION LINE 6" C-900 PVC FIRE PROTECTION LINE HYDRANT ASSEMBLY (TYP) HYDRANT ASSEMBLY (TYP) ADJUST EX STM MH RIM TO ELEVATION 715.00 26.9 L.F. 18" HDPE @ S=1.30% 44.6 L.F. 10" SCH-40 PVC @ S=2.08% 38.2 L.F. 18" HDPE @ S=1.00% 142.5 L.F. 15" HDPE @ S=0.80% 77.7 L.F. 10" HDPE @ S=0.80% 45° BEND 35.4 INV=711.57 (10" SE) INV=711.57 (10" W) 100.0' ELECTRIC TRANSMISSION LINE EASEMENT PER CSM 9530 AND PER DOC NO. 11325362 28.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 30.0' FRONT BUILDING SETBACK 25.0' REAR BUILDING SETBACK 16.0' STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530 AND PER DOC NO. 11346142 20' STORMWATER DRAINAGE EASEMENT PER CSM 9530 AND PER DOC NO. 11346144 50' WETLAND SETBACK PER CSM 9530 30' WETLAND BUFFER PER CSM 9530 SOUTH HICKORY STREET (120' PUBLIC R.O.W.) STORMWATER MANAGEMENT ACCESS EASEMENT PER CSM 9530, DOC NO. 11346142, AND DOC NO. 11346145 45° BEND 35.2 INV=713.05 (8") 5.3 L.F. 10" SDR-35 PVC @ S=1.04% INL 34.1 INV=710.95 (10" E) INV=712.07 (10" S) INV=710.95 (15" W) PROPERTY LINE CONNECT TO EXISTING 6" SANITARY STUB INV=±695.89 (10" W) (EX.) CONTRACTOR TO FIELD VERIFY EX. INV AND NOTIFY ENGINEER OF ANY DISCREPANCIES VISION CLEARANCE AREA VISION CLEARANCE AREA CONSERVATION EASEMENT PER CSM 9530 AND PER DOC NO. 11372007 DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI UTILITY PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM UTILITY PLAN 1CITY COMMENTS11/09/26C-19 1" = 30' UTILITY PLAN FRANKLIN SIX SIBS 1" = 30' 060' GRAPHICAL SCALE (FEET) NORTH CONSTRUCTION NOTES LOCATED ON SHEET C-2 CONTRACTOR RESPONSIBILITY: SEE ADDITIONAL LEGEND SANITARY SEWER MANHOLE STORM SEWER INLET / CATCH BASIN (ROUND CASTING) STORM SEWER INLET / CATCH BASIN (RECTANGULAR CASTING) FLARED END SECTION / END APRON CLEANOUT VALVE BOX FIRE HYDRANT PROPOSED COMBINED SEWER STORM SEWER MANHOLE PROPOSED DRAIN TILE PROPOSED ELECTRIC PROPOSED FIBER OPTIC PROPOSED FIRE PROTECTION PROPOSED GAS PROPOSED SANITARY SEWER PROPOSED SANITARY FORCEMAIN PROPOSED INLET DRAIN TILE (DRAIN TILE DONUT, SEE DETAIL) PROPOSED STORM SEWER PROPOSED TELEPHONE PROPOSED WATERMAINW LIGHT POLE ELECTRIC TRANSFORMER UTILITY CROSSING DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2025 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI CONSTRUCTION DETAILS.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM CONSTRUCTION DETAILS 1CITY COMMENTS11/09/26C-20 N.T.S. CONSTRUCTION DETAILS FRANKLIN SIX SIBS STABILIZATION TYPE JAN.FEB.MAR.APR.MAYJUNEJULYAUG.SEPT.OCT.NOV.DEC. PERMANENT SEEDING DORMANT SEEDING TEMPORARY SEEDING SODDING B A** B C E D A.KENTUCKY BLUEGRASS 90 LBS/ACRE MIXED WITH PERENNIAL RYEGRASS 30 LBS/ACRE. B.KENTUCKY BLUEGRASS 135 LBS/ACRE MIXED WITH PERENNIAL RYEGRASS 45 LBS/ACRE + 2 TONS STRAW MULCH/ACRE. C.SPRING OATS 100 LBS/ACRE. D.WHEAT OR CEREAL RYE 150 LBS/ACRE. E.SOD. F.STRAW MULCH 2 TONS/ACRE. * IRRIGATION/WATERING REQUIRED TO SUPPORT ESTABLISHMENT AS NEEDED. STABILIZATION EFFECTIVENESS (TIME OF YEAR) STABILIZATION UTILIZATION PERIODS CONTROL MEASURE GROUP VEGETATIVE SOIL COVER NON VEGETATIVE SOIL COVER DIVERSIONS ENCLOSED DRAINAGE OUTLETS SEDIMENT FILTERS MUD AND DUST CONTROL STREET SWEEPING CONSTRUCTION ENTRANCE CONTROL MEASURE DITCH CHECK SILT FENCE APRON ENDWALL OR RIPRAP STORM SEWER DIVERSION BERM / SWALE PAVING AGGREGATE COVER PERMANENT SEEDING TEMPORARY SEEDING SEDIMENT BASINSTEMPORARY SEDIMENT TRAP REDUCES POLLUTANTS TRACKED FROM CONSTRUCTION SITE. REDUCES SOIL EROSION POLLUTANTS BEING TRANSPORTED OFF-SITE. PLACED IN DRAINAGE CHANNELS TO FILTER SEDIMENT FROM RUNOFF. PLACED DOWN SLOPE OF DISTURBED AREA TO KEEP RUNOFF CONTAINED ON-SITE. PROTECTS DOWNSTREAM CHANNEL FROM HIGH VELOCITY OF FLOW DISCHARGING FROM STRUCTURE. CONVEYS SEDIMENT LADEN WATER TO A SEDIMENT BASIN. DIVERTS RUNOFF TO A SEDIMENT TRAP OR OTHER CONTROL. PROVIDES PERMANENT COVER ON PARKING LOTS AND ROADS OR OTHER AREAS WHERE VEGETATION CANNOT BE ESTABLISHED. PROVIDES TEMPORARY COVER ON ROADS AND PARKING LOTS AND AREAS WHERE VEGETATION CANNOT BE ESTABLISHED. PREVENTS MUD FROM BEING PICKED UP AND TRANSPORTED OFF-SITE. PROVIDES PERMANENT VEGETATIVE COVER TO CONTROL EROSION, FILTERS SEDIMENT FROM WATER. MAY BE PART OF FINAL LANDSCAPE PLAN. PROVIDES QUICK TEMPORARY COVER TO CONTROL EROSION WHEN PERMANENT SEEDING IS NOT DESIRED OR TIME OF YEAR IS INAPPROPRIATE. CONSTRUCTED TO REMOVE SILTATION FROM RUNOFF FROM SITE DIVERSION BERMS/SWALES AND IN OVERLAND FLOOD ROUTE. CAN BE CONVERTED TO PERMANENT SEDIMENT BASIN. CONTROL MEASURE CHARACTERISTICS INLET PROTECTIONINSTALLED IN OPEN GRATE STRUCTURES TO COLLECT SEDIMENT. DUST CONTROLPREVENTS DUST FROM LEAVING CONSTRUCTION SITE. 1.0POTENTIAL POLLUTANT SOURCES GIVEN THE PROPOSED ACTIVITY ON THE PROJECT SITE, THE PRIMARY POTENTIAL POLLUTANT SOURCE ASSOCIATED WITH THIS CONSTRUCTION PROJECT IS SOIL EROSION AND TRANSPORTATION; REFER TO SECTION 4 OF THIS PLAN. ADDITIONAL POTENTIAL SOURCES OF POLLUTION MAY INCLUDE: FUEL TANKS, WASTE CONTAINERS, OIL OR OTHER PETROLEUM PRODUCTS, DETERGENTS, PAINTS, CONSTRUCTION DEBRIS, SANITARY STATIONS, FERTILIZERS, AND DUST; REFER TO SECTION 5 OF THIS PLAN. 2.0EROSION AND SEDIMENT CONTROL IMPLEMENTATION THE FOLLOWING ARE DESCRIPTIONS OF THE EROSION AND SEDIMENT CONTROL PRACTICES THAT SHALL BE IMPLEMENTED DURING CONSTRUCTION OF THIS PROJECT. IN ADDITION TO THESE MEASURES, CONTRACTOR SHALL DISTURB ONLY AREAS NECESSARY TO COMPLETE THE CONSTRUCTION PROJECT. ALL PRACTICES SHALL BE CONDUCTED IN ACCORDANCE WITH THE BEST MANAGEMENT PRACTICES (BMP). 2.1 CONSTRUCTION AND EROSION CONTROL SEQUENCING CONSTRUCTION SEQUENCING WILL BE UTILIZED AS A MEANS OF CONTROLLING EROSION AND LIMITING SEDIMENT TRANSPORT. SEQUENCING AS LISTED BELOW IS GENERAL IN NATURE AND MAY VARY DEPENDING ON WEATHER CONDITIONS AND/OR PHASING OF CONSTRUCTION. THE CONTRACTOR SHALL SUBMIT A DETAILED SITE SEQUENCING PLAN TO OWNER FOR APPROVAL AT LEAST 5 BUSINESS DAYS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. CONTRACTOR MAY MODIFY SEQUENCING AFTER ITEM 6 AS NEEDED TO COMPLETE CONSTRUCTION ONLY IF EROSION CONTROLS ARE MAINTAINED IN ACCORDANCE WITH THE CONSTRUCTION SITE EROSION AND SEDIMENT CONTROL REQUIREMENTS. 1.INSTALL TEMPORARY CONSTRUCTION ENTRANCES, INLET PROTECTION ON EXISTING STORM SEWER AND CULVERT INLET LOCATIONS, AND PERIMETER SILT FENCING. 2.INSTALL SILT FENCING ALONG THE PERIMETER OF PROPOSED TOPSOIL STOCKPILE LOCATIONS. THE FIRST TOPSOIL DEPOSITED WITHIN THE STOCKPILE LIMITS SHALL BE PLACED TO CREATE TEMPORARY BERMING ALONG THE SILT FENCE TO PREVENT DIRECT STORMWATER RUNOFF AGAINST SILT FENCING. CONTRACTOR SHALL LIMIT LAND DISTURBING ACTIVITIES ASSOCIATED WITH TEMPORARY BERMING TO A MINIMUM. 3.STRIP TOPSOIL WITHIN THE LIMITS OF THE SEDIMENT TRAPS THAT WILL BE USED FOR TEMPORARY SEDIMENT CONTROL. STRIPPED TOPSOIL SHALL BE PLACED TO CONSTRUCT DIVERSION BERMING OR PLACED WITHIN THE STOCKPILE LIMITS. 4.STRIP TOPSOIL ALONG THE REMAINDER OF DIVERSION BERMING AND IMMEDIATELY PLACE TOPSOIL TO CREATE THE BERMING. MASS TOPSOIL STRIPPING SHALL NOT OCCUR UNTIL ALL DOWNSTREAM SEDIMENT CONTROLS ARE IN PLACE. 5.CONDUCT ROUGH GRADING OPERATIONS AND UTILITY PIPING INSTALLATION. DRAIN TILE SHALL NOT BE INSTALLED UNTIL UPLAND AREAS CONTRIBUTING STORMWATER RUNOFF ARE STABILIZED. DITCH CHECKS SHALL BE INSTALLED WITHIN DRAINAGE DITCHES IMMEDIATELY FOLLOWING CREATION OF DITCHES AND INLET PROTECTION SHALL BE INSTALLED TO PROTECT ANY STORM SEWER OR CULVERTS THAT WILL FUNCTION DURING CONSTRUCTION. 6.FINE GRADE SUB-GRADE SOILS WITHIN PAVEMENT AND BUILDING LIMITS. PLACE STONE BASE MATERIAL AS SOON AS POSSIBLE FOLLOWING COMPLETION OF FINE GRADING EFFORTS. 7.FINE GRADE REMAINING DISTURBED AREAS. PLACE SALVAGED TOPSOIL, EROSION BLANKETS/MATTING, AND SEED/MULCH AS SOON AS POSSIBLE FOLLOWING COMPLETION OF FINE GRADING EFFORTS. 8.EROSION CONTROLS SHALL NOT BE REMOVED UNTIL SITE IS FULLY STABILIZED OR 70% VEGETATIVE COVER IS ESTABLISHED. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF SILT FENCE, TEMPORARY FENCING/PRETECTION, DITCH CHECKS, AND OTHER TEMPORARY CONTROLS, AND RESTORATION PRACTICES AS NECESSARY, TO THE SATISFACTION OF THE OWNER. 2.2 STABILIZATION PRACTICES THE DATES WHEN MAJOR GRADING ACTIVITIES OCCUR, WHEN CONSTRUCTION ACTIVITIES TEMPORARILY OR PERMANENTLY CEASE ON A PORTION OF THE SITE, AND WHEN STABILIZATION MEASURES ARE INITIATED, SHALL BE RECORDED ON THE STABILIZATION SCHEDULE FOR MAJOR GRADING ACTIVITIES. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED. NO MORE THAN SEVEN (7) DAYS SHALL PASS AFTER THE CONSTRUCTION ACTIVITY IN THAT PORTION OF THE SITE HAS PERMANENTLY CEASED UNLESS: THE INITIATION OF STABILIZATION MEASURES BY THE SEVENTH (7) DAY AFTER CONSTRUCTION ACTIVITY TEMPORARILY OR PERMANENTLY CEASE IS PRECLUDED BY SNOW COVER. IN THAT EVENT, STABILIZATION MEASURE SHALL BE INITIATED AS SOON AS PRACTICABLE. CONSTRUCTION ACTIVITY WILL RESUME ON A PORTION OF THE SITE WITHIN FOURTEEN (14) DAYS FROM WHEN ACTIVITIES CEASED, (I.E. THE TOTAL TIME PERIOD THAT THE CONSTRUCTION ACTIVITY IS TEMPORARILY CEASED IS LESS THAN FOURTEEN (14) DAYS). IN THAT EVENT, STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE BY THE SEVENTH (7) DAY AFTER CONSTRUCTION ACTIVITY HAS TEMPORARILY CEASED. SEE THE SOIL PROTECTION CHART PRESENTED IN THE CONSTRUCTION DOCUMENTS FOR RATES OF PERMANENT AND TEMPORARY VEGETATION. STABILIZATION MEASURES SHALL BE DETERMINED BASED ON SITE CONDITIONS AT THE TIME CONSTRUCTION ACTIVITY HAS CEASED, INCLUDING BUT NOT LIMITED TO WEATHER CONDITIONS AND LENGTH OF TIME MEASURE MUST BE EFFECTIVE. THE FOLLOWING ARE ACCEPTABLE STABILIZATION MEASURES. PERMANENT SEEDING; IN ACCORDANCE WITH APPROVED LANDSCAPING PLAN TEMPORARY SEEDING MAY CONSIST OF SPRING OATS (100LBS/ACRE) AND/OR WHEAT OR CEREAL RYE (150LBS/ACRE) HYDRO-MULCHING WITH A TACKIFIER GEOTEXTILE EROSION MATTING SODDING 2.3 STRUCTURAL PRACTICES THE FOLLOWING ARE DESCRIPTIONS OF STRUCTURAL PRACTICES TO BE IMPLEMENTED TO DIVERT FLOWS FROM EXPOSED SOILS, STORE FLOWS, OR OTHERWISE LIMIT THE DISCHARGE OF POLLUTANTS FROM EXPOSED AREAS OF THE SITE INCLUDING THE PROPOSED AND EXISTING WETLAND AREAS. SUCH PRACTICES COULD INCLUDE SILT FENCE, PROTECTION FENCE, CONSTRUCTION ENTRANCE, DITCH CHECK, EROSION CONTROL MATTING, DIVERSION BERM/SWALE, SEDIMENT TRAP, LEVEL SPREADER, INLET PROTECTION, OUTLET PROTECTION, AND TEMPORARY OR PERMANENT SEDIMENT BASIN. THE FOLLOWING STRUCTURAL PRACTICES ARE TO BE UTILIZED DURING THIS PROJECT. SILT FENCE SHALL BE PLACED DOWN SLOPE OF DISTURBED AREAS OF THE CONSTRUCTION SITE AND AROUND THE PERIMETER OF THE TOPSOIL STOCKPILE. THIS INCLUDES PROTECTION OF EXISTING WETLAND AREAS TO BE MAINTAINED. SILT FENCE MAY ALSO BE USED AS A TEMPORARY CONTROL DEVICE WHERE SEDIMENTATION RUNOFF IS DISCOVERED. CONSTRUCTION ENTRANCE SHALL BE INSTALLED TO REDUCE SOIL EROSION POLLUTANTS FROM LEAVING THE SITE DURING CONSTRUCTION ACTIVITIES. IF THE CRUSHED STONE DOES NOT ADEQUATELY REMOVE MUD FROM VEHICLE TIRES, THEY SHALL BE HOSED OFF BEFORE ENTERING A PAVED ROADWAY. ANY SOIL DEPOSITED ON THE PUBLIC PAVED ROAD WAY SHALL BE REMOVED IMMEDIATELY. DITCH CHECK (STRAW BALES) SHALL BE INSTALLED IN DRAINAGE CHANNELS AS NEEDED. EROSION CONTROL MATTING SHALL BE PLACED ON AREAS OR EMBANKMENTS HAVING SLOPES GREATER THAN OR EQUAL TO 3H:1V, BEFORE VEGETATION IS ESTABLISHED. DIVERSION BERM/SWALE SHALL BE CONSTRUCTED TO DIVERT RUNOFF AROUND THE SITE AND TO DIVERT RUNOFF FROM THE DISTURBED AREA TO A SEDIMENT TRAP OR OTHER CONTROL. BERMS/SWALES SHALL BE STABILIZED WITH EQUIPMENT TRACKING AND TEMPORARY SEEDING. SEDIMENT TRAPS/BASIN SHALL BE CONSTRUCTED TO COLLECT RUNOFF AND RUNOFF FROM SITE DIVERSION BERMS/SWALES. INLET PROTECTION SHALL BE INSTALLED AT STORMWATER DRAINAGE INLETS TO REDUCE SEDIMENT WITHIN STORM SEWER CONVEYANCE FEATURES. OUTLET SCOUR PROTECTION SHALL BE INSTALLED AT STORMWATER DRAINAGE OUTLETS TO DIFFUSE FLOWS. 3.0ADDITIONAL PRACTICES ADDITIONAL POLLUTANT CONTROL MEASURES TO BE IMPLEMENTED DURING CONSTRUCTION ACTIVITIES SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING. CONSTRUCTION WASTE SHALL BE PROPERLY DISPOSED OF. THIS INCLUDES ALL CONSTRUCTION SITE WASTE MATERIAL, SANITARY WASTE, AND WASTE FROM VEHICLE TRACKING OF SEDIMENTS. THE CONTRACTOR SHALL ENSURE THAT NO MATERIAL WASTES OR UNUSED BUILDING MATERIALS SHALL BE BURIED, DUMPED, BURNED, OR DISCHARGED TO THE WATERS OF THE STATE. VEHICLES HAULING MATERIAL AWAY FROM THE SITE SHALL BE COVERED WITH A TARPAULIN TO PREVENT BLOWING DEBRIS. DUST CONTROL SHALL BE ACCOMPLISHED BY ONE OR MORE OF THE FOLLOWING METHODS: COVERING 30% OR MORE OF THE SOIL SURFACE WITH A NON-ERODIBLE MATERIAL. ROUGHENING (EQUIPMENT TRACKING) THE SOIL TO PRODUCE RIDGES PERPENDICULAR TO THE PREVAILING WIND. RIDGES SHALL BE AT LEAST SIX (6) INCHES IN HEIGHT. FREQUENT WATERING OF EXCAVATION AND FILL AREAS. PROVIDING GRAVEL OR PAVING AT ENTRANCE/EXIT DRIVES, PARKING AREAS AND TRANSIT PATHS. STREET SWEEPING SHALL BE PERFORMED TO IMMEDIATELY REMOVE ANY SEDIMENT TRACKED ON PAVEMENTS. 4.0EROSION AND SEDIMENT STRUCTURAL PRACTICE MAINTENANCE THE FOLLOWING MAINTENANCE PRACTICES SHALL BE USED TO MAINTAIN, IN GOOD AND EFFECTIVE OPERATING CONDITIONS, VEGETATION, EROSION AND SEDIMENT CONTROL MEASURES, AND OTHER PROTECTIVE MEASURES IDENTIFIED IN THIS PLAN. UPON IDENTIFICATION, DEFICIENCIES IN STORMWATER CONTROLS SHALL BE ADDRESSED IMMEDIATELY. THE MAINTENANCE PROCEDURES FOR THIS DEVELOPMENT SHALL INCLUDE, BUT NOT BE LIMITED TO THE BELOW. SILT FENCE - REPAIR OR REPLACE ANY DAMAGED FILTER FABRIC AND/OR STAKES. REMOVE ACCUMULATED SEDIMENT WHEN IT HAS REACHED ONE-HALF THE ABOVE GROUND HEIGHT OF THE FENCE. CONSTRUCTION ENTRANCE - AS NEEDED, ADD STONE TO MAINTAIN CONSTRUCTION ENTRANCE DIMENSIONS AND EFFECTIVENESS. DITCH CHECK (STRAW BALES) - RE-SECURE STAKES; ADJUST OR REPOSITION BALES TO ADDRESS PROPER FLOW OF STORMWATER; AND REMOVE ACCUMULATED SEDIMENT WHEN IT HAS REACHED ONE-HALF THE HEIGHT OF THE BALE. EROSION CONTROL MATTING - REPAIR MATTING IMMEDIATELY IF INSPECTION REVEALS BREACHED OR FAILED CONDITIONS. REPAIR AND RE-GRADE SOIL WHERE CHANNELIZATION HAS OCCURRED. DIVERSION BERM/SWALE - REPLACE OR RE-COMPACT THE CONSTRUCTION MATERIALS AS NECESSARY. SEDIMENT TRAP - REMOVE AND DISPOSE OF THE ACCUMULATED SEDIMENT WHEN IT HAS REACHED THE SEDIMENT STORAGE ELEVATION. INLET PROTECTION - CLEAN, REPAIR OR REPLACE FILTER FABRIC AND/OR STONE WHEN CONTROL MEASURE IS CLOGGED. INLET FILTER BAGS SHALL BE REPLACED ONCE ONE-HALF FULL OF SEDIMENT. OUTLET PROTECTION - CLEAN, REPAIR OR REPLACE FILTER FABRIC, TURF REINFORCEMENT MATTING AND/OR STONE WHEN CONTROL MEASURE IS ONE-HALF FULL OF SEDIMENT. SEDIMENT BASIN - AT THE END OF CONSTRUCTION, CONTRACTOR SHALL REMOVE AND DISPOSE OF THE ACCUMULATED SEDIMENT AND RESTORE BASIN AREA TO INTENDED POST-CONSTRUCTION DESIGN GRADES. 5.0INSPECTION INSPECTIONS SHALL BE COMPLETED WITHIN TWENTY-FOUR (24) HOURS OF THE END OF A RAINFALL EVENT THAT IS ONE-HALF INCH OR GREATER OR EQUIVALENT SNOWFALL, OR AT A MINIMUM ONCE EVERY SEVEN (7) CALENDAR DAYS. INSPECTIONS SHALL BE UNDERTAKEN BY QUALIFIED PERSONNEL PROVIDED BY THE CONTRACTOR, AND SHALL INCLUDE: DISTURBED AREAS OF THE CONSTRUCTION SITE THAT HAVE NOT BEEN FINALLY STABILIZED, STRUCTURAL CONTROL MEASURES, AND LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE. A STORMWATER POLLUTION PREVENTION PLAN INSPECTION REPORT SHALL BE COMPLETED AND ADDED TO THE SWPPP. RAINFALL SHALL BE RECORDED ON THE SWPPP RAINFALL LOG. CONTRACTOR SHALL IMMEDIATELY ARRANGE FOR REPAIR OR REPLACEMENT OF ANY DAMAGED OR DEFICIENT CONTROL MEASURES OBSERVED DURING THE INSPECTION. QUALIFIED PERSONNEL MEANS A PERSON KNOWLEDGEABLE IN THE PRINCIPLES AND PRACTICES OF EROSION AND SEDIMENT CONTROL MEASURES, SUCH AS A LICENSED PROFESSIONAL ENGINEER, A CERTIFIED PROFESSIONAL IN EROSION AND SEDIMENT CONTROL, A CERTIFIED EROSION SEDIMENT OR STORMWATER INSPECTOR, OR OTHER TRAINED INDIVIDUAL. 6.0SPILL PREVENTION 6.1 GENERAL MATERIAL MANAGEMENT PRACTICES THE GOOD HOUSEKEEPING PRACTICES LISTED BELOW SHALL BE FOLLOWED THROUGHOUT THE CONSTRUCTION PROJECT. 1.CONTRACTOR SHALL STORE ONLY ENOUGH PRODUCTS REQUIRED TO COMPLETE THIS PROJECT. 2.ALL MATERIAL SHALL BE STORED IN A NEAT, ORDERLY MANNER IN THEIR ORIGINAL CONTAINERS CONTAINING MANUFACTURER'S LABEL. 3.MANUFACTURERS' RECOMMENDATIONS FOR PROPER USE AND DISPOSAL SHALL BE FOLLOWED. 4.MATERIALS REQUIRED TO HAVE A MATERIAL SAFETY DATA SHEET (MSDS) SHALL HAVE A COPY STORED IN THE PROJECT'S MSDS DATABASE. 6.2 SPILL CONTROL PRACTICES THE PRACTICES LISTED BELOW SHALL BE FOLLOWED FOR SPILL PREVENTION AND CLEANUP. 1.MATERIALS AND EQUIPMENT NECESSARY FOR SPILL CLEANUP SHALL BE MAINTAINED ONSITE. 2.IMMEDIATELY UPON DISCOVERY, ALL SPILLS SHALL BE CLEANED UP ACCORDING TO THE MANUFACTURERS' RECOMMENDED METHODS. 3.PERSONNEL CLEANING UP A SPILL SHALL USE PERSONAL PROTECTIVE EQUIPMENT. 4.IMMEDIATELY UPON DISCOVERY, SPILLS OF TOXIC OR HAZARDOUS MATERIALS SHALL BE REPORTED TO THE OWNER AND GENERAL CONTRACTOR. 5.NOTIFICATION AND REPORTING TO THE APPROPRIATE FEDERAL, STATE, AND LOCAL GOVERNMENT AGENCIES SHALL BE MADE AS REQUIRED. GENERAL INFORMATION: THIS STORMWATER POLLUTION PREVENTION PLAN (SWPPP) HAS BEEN DEVELOPED TO FULFILL ONE OF THE REQUIREMENTS OF THE GENERAL ENVIRONMENTAL PROTECTION AGENCY (EPA) NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (WISCONSIN POLLUTION DISCHARGE ELIMINATION SYSTEM "WPDES" PERMIT NO. WI-S067831-4) FOR THE DISCHARGE OF STORMWATER ASSOCIATED WITH CONSTRUCTION PROJECTS DISTURBING ONE ACRE OR MORE. THE OWNER AND CONTRACTORS SHALL COMPLY WITH ALL REQUIREMENTS OF THE WPDES FOR ALL SUCH CONSTRUCTION PROJECTS. THE STORMWATER DISCHARGES ASSOCIATED WITH THE CONSTRUCTION ACTIVITY FROM THIS SITE ARE SUBJECT TO THE CONDITIONS AND REQUIREMENTS OF THE PERMITS. THE EXECUTED OWNER CERTIFICATION AND THE CONTRACTOR CERTIFICATIONS SHALL BE KEPT ONSITE WITH THE APPROVED PLANS. SWPPP AVAILABILITY: THE OWNER SHALL RETAIN A COPY OF THE SWPPP AT THE CONSTRUCTION SITE FROM THE DATE OF THE PROJECT INITIATION TO THE DATE OF FINAL STABILIZATION. KEEPING PLANS CURRENT: THE CONTRACTOR SHALL AMEND THE PLAN WHENEVER THERE IS A CHANGE IN DESIGN, CONSTRUCTION, OPERATION, OR MAINTENANCE, WHICH HAS A SIGNIFICANT EFFECT ON THE POTENTIAL FOR THE DISCHARGE OF POLLUTANTS TO THE WATERS OF THE STATE AND WHICH HAS NOT OTHERWISE BEEN ADDRESSED IN THE PLAN OR IF THE PLAN PROVES TO BE INEFFECTIVE IN ELIMINATING OR SIGNIFICANTLY CONTROLLING POLLUTANTS IN STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION SITE ACTIVITY. IN ADDITION, THE THE PLAN SHALL BE AMENDED TO IDENTIFY ANY NEW CONTRACTOR AND/OR SUBCONTRACTOR THAT WILL IMPLEMENT A MEASURE OF THE PLAN. AMENDMENTS TO THE PLAN MAY BE REQUIRED BY THE MUNICIPALITY, OWNER, OR OTHER REVIEWING AGENCY. COPIES OF THE AMENDMENTS SHALL BE KEPT ONSITE AS PART OF THE SWPPP. RETENTION OF RECORDS: THE OWNER SHALL RETAIN COPIES OF THIS AND ALL REPORTS AND NOTICES REQUIRED BY THIS PERMIT, AND RECORDS OF ALL DATA USED TO COMPLETE THE NOTICE OF INTENT TO BE COVERED BY THIS PERMIT, FOR A PERIOD OF AT LEAST THREE YEARS FROM THE DATE PERMIT COVERAGE EXPIRES OR IS TERMINATED. THIS PERIOD MAY BE EXTENDED BY THE REQUEST OF THE AGENCY AT ANY TIME. IN ADDITION, THE OWNER SHALL RETAIN A COPY OF THE PLAN REQUIRED BY THIS PERMIT AT THE CONSTRUCTION SITE FROM THE DATE OF PROJECT INITIATION TO THE DATE OF FINAL STABILIZATION. A NOTICE OF INTENT (NOI) APPLICATION MUST BE COMPLETED AND INCORPORATED INTO THE SWPPP. WPDES NOTICE OF TERMINATION GUIDANCE: WHEN A SITE HAS BEEN FINALLY STABILIZED AND ALL STORMWATER DISCHARGES FROM CONSTRUCTION SITES THAT ARE AUTHORIZED BY THE PERMIT ARE ELIMINATED, THE OWNER OF THE FACILITY MUST SUBMIT A COMPLETED NOTICE OF TERMINATION THAT IS SIGNED IN ACCORDANCE WITH THE PERMIT. CONTRACTOR SHALL SUBMIT A COMPLETED NOTICE OF TERMINATION TO OWNER FOR EXECUTION PRIOR TO THEIR FINAL PAY APPLICATION REQUEST. * *** ** * *** ** * *** 1.17' MIN FLOW TRENCH DETAIL 2 NOTE: ADDITIONAL POST DEPTH OR TIE BACKS MAY BE REQUIRED IN UNSTABLE SOILS 2.33' MAX FLOW DIRECTION NOTES: 1.ALL SILT FENCE MATERIALS AND INSTALLATION SHALL BE IN CONFORMANCE WITH WI DNR TECHNICAL STANDARD 1056. 2.GEOTEXTILE FABRIC SHALL MEET THE REQUIREMENTS OF MATERIAL SPECIFICATION 592 GEOTEXTILE TABLE 1 OR 2, CLASS I WITH EQUIVALENT OPENING SIZE OF AT LEAST 30 FOR NONWOVEN AND 50 FOR WOVEN. 3.SILT FENCE SHALL BE ANCHORED BY SPREADING AT LEAST 8-INCHES OF FABRIC IN A 4-INCH WIDE AND 6-INCH DEEP TRENCH OR 6-INCH DEEP V-TRENCH ON THE UPSLOPE SIDE OF THE FENCE. TRENCHES SHALL NOT BE EXCAVATED WIDER OR DEEPER THAN NECESSARY FOR PROPER INSTALLATION. 4.FOLD MATERIAL TO FIT TRENCH AND BACKFILL AND COMPACT TRENCH WITH EXCAVATED SOIL. 5.WOOD POSTS SHALL BE A MINIMUM SIZE OF 1.125-INCHES x 1.125-INCHES OF DRIED OAK OR HICKORY. 6.SILT FENCE TO EXTEND ABOVE THE TOP OF PIPE, WHERE APPLICABLE. 7.POST SPACING SHALL BE SELECTED BASED ON GEOTEXTILE FABRIC (8-FEET FOR WOVEN AND 3-FEET FOR NON-WOVEN). WOOD POSTS LENGTH 3' - 4' 20" MIN. DEPTH IN GROUND BACKFILL AND COMPACT TRENCH WITH EXCAVATED SOIL GEOTEXTILE FABRIC ONLY SILT FENCE SHALL BE STAPLED, USING AT LEAST 0.5-INCH STAPLES, TO THE UPSLOPE SIDE OF THE POSTS IN AT LEAST 3 PLACES NYLON CORD SEAM FOLD 3" MAX. 1 2 GEOTEXTILE FABRIC FLOW DIRECTION EXPRESS FABRIC 8.0' MAX SEE NOTE 6 8.0' MAX SEE NOTE 6 SILT FENCE 1 #100-C 07-31-14 INLET PROTECTION#105 06-20-14 INSTALLATION NOTES: 1.DO NOT INSTALL INLET PROTECTION TYPE "D" IN INLETS SHALLOWER THAN 30 INCHES, MEASURED FROM THE BOTTOM OF THE INLET TO THE TOP OF THE GRATE. 2.TRIM EXCESS FABRIC IN THE FLOW LINE TO WITHIN 3 INCHES OF THE GRATE. 3.THE INSTALLED BAG SHALL HAVE A MINIMUM SIDE CLEARANCE, BETWEEN THE INLET WALLS AND THE BAG, MEASURED AT THE BOTTOM OF THE OVERFLOW HOLES, OF 3 INCHES. WHERE NECESSARY THE CONTRACTOR SHALL CINCH THE BAG, USING PLASTIC ZIP TIES, TO ACHIEVE THE 3 INCHES CLEARANCE. THE TIES SHALL BE PLACED AT A MAXIMUM OF 4 INCHES FROM THE BOTTOM OF THE BAG. NOTES: 1.INLET PROTECTION DEVICES SHALL BE MAINTAINED OR REPLACED AT THE DIRECTION OF THE ENGINEER. 2.MANUFACTURED ALTERNATIVES APPROVED AND LISTED ON THE WisDOT EROSION CONTROL PRODUCT ACCEPTABILITY LIST MAY BE SUBSTITUTED. 3.WHEN REMOVING OR MAINTAINING INLET PROTECTION, CARE SHALL BE TAKEN SO THAT THE SEDIMENT TRAPPED ON THE GEOTEXTILE FABRIC DOES NOT FALL INTO THE INLET. ANY MATERIAL FALLING INTO THE INLET SHALL BE REMOVED IMMEDIATELY. 1FINISHED SIZE, INCLUDING FLAP POCKETS WHERE REQUIRED, SHALL EXTEND A MINIMUM OF 10 INCHES AROUND THE PERIMETER TO FACILITATE MAINTENANCE OR REMOVAL. 2FLAP POCKETS SHALL BE LARGE ENOUGH TO ACCEPT WOOD 2 INCH X 4 INCH. INLET SPECIFICATIONS AS PER PLAN, DIMENSION LENGTH AND WIDTH TO MATCH GEOTEXTILE FABRIC, TYPE "FF" 2.0' FLAP POCKET USE REBAR OR STEEL ROD FOR REMOVAL OR FOR INLETS WITH CAST CURB BOX USE WOOD 2"x4", EXTEND 10" BEYOND GRATE WIDTH ON BOTH SIDES, LENGTH VARIES. SECURE TO GRATE WITH WIRE OR PLASTIC TIES. FRONT, BACK, AND BOTTOM TO BE MADE FROM SINGLE PIECE OF FABRIC. MINIMUM DOUBLE STITCHED SEAMS ALL AROUND SIDE PIECES AND ON FLAP POCKETS. 1.00' 2 1 2 4" x 6" OVAL HOLE SHALL BE HEAT CUT INTO ALL FOUR SIDE PANELS #107-WI 10-02-12 CONSTRUCTION ENTRANCE 12.0' MIN. 1.0' MIN. 50.0' MIN. LENGTH NOTES: 1.ALL TRACKING PAD MATERIALS AND INSTALLATION SHALL BE IN CONFORMANCE WITH WI DNR TECHNICAL STANDARD 1057. 2.TRACKING PADS SHALL BE INSTALLED PRIOR TO ANY TRAFFIC LEAVING THE SITE. CONTRACTOR SHALL VERIFY LOCATION WITH OWNER. 3.THE AGGREGATE FOR TRACKING PADS SHALL BE 3 TO 6 INCH CLEAR OR WASHED STONE. ALL MATERIALS TO BE RETAINED ON A 3-INCH SIEVE 4.THE AGGREGATE SHALL BE PLACED IN A LAYER AT LEAST 12-INCHES THICK. ON SITES WHERE SATURATED CONDITIONS ARE EXPECTED DURING THE LIFE OF THE PAD, THE PAD SHALL BE UNDERLAIN WITH GEOTEXTILE FABRIC WHICH MEETS MATERIAL SPECIFICATION 592 GEOTEXTILE, TABLE 1 OR 2, CLASS I, II OR IV, TO PREVENT MIGRATION OF UNDERLYING SOILS INTO THE STONE LAYER. 5.THE TRACKING PAD SHALL BE THE FULL WIDTH OF THE EGRESS POINT. MINIMUM WIDTH IS 12 FEET FOR ONE-WAY TRAFFIC AND 20 FEET FOR TWO-WAY TRAFFIC, WITH AN ADDITIONAL INCREASE OF 4 FEET FOR TRAILER TRAFFIC. THE TRACKING PAD SHALL BE A MINIMUM 50-FEET LONG. 6.ANY SEDIMENT TRACKED ONTO A PUBLIC OR PRIVATE ROAD SHOULD BE REMOVED BY STREET CLEANING, NOT FLUSHING, AT THE END OF EACH WORKING DAY. 7.TRACKING PADS SHALL, AT A MINIMUM, BE INSPECTED WEEKLY AND WITHIN 24-HOURS AFTER EVERY PRECIPITATION EVENT THAT PRODUCES 0.5-INCHES OF RAIN OR MORE DURING A 24-HOUR PERIOD. 8.THE TRACKING PAD PERFORMANCE SHALL BE MAINTAINED BY SCRAPING OR TOP-DRESSING WITH ADDITIONAL AGGREGATE. AGGREGATE OVER GEOTEXTILE FABRIC EXISTING ROAD 20.0'10.0'20.0' 0.50' EXISTING PAVEMENT PROFILE VIEW SLOPE SLOPE 3'' TO 6'' WASHED OR CLEAR STONE D/2 MIN. 2.0' RIP RAP AT END SECTIONS #124A 12/26/12 PLAN VIEW END VIEW L*= 3 TIMES PIPE DIAMETER (TYP.) OR 10 FOOT MIN. OR AS DIRECTED BY THE ENGINEER 5 1 5 1 SIDE VIEW RIPRAP RIPRAP 2.0' RIPRAP L* VARIES 1/2 END SECTION LENGTH TWICE PIPE DIAMETER NOTES: 1.RIP RAP AND GEOTEXTILE FABRIC SHALL MEET REQUIREMENTS FOR STANDARD SPECIFICATIONS FOR HIGHWAY AND STRUCTURE CONSTRUCTION. COVER EXPOSED END SECTION WITH RIPRAP JOINT RESTRAINTS "TIE BOLTS" REQ'D FOR LAST THREE JOINTS (2 BOLTS PER JOINT @ MIN 60° SEPARATION) ANCHOR WITH SOIL OR STAPLES GEOTEXTILE SEPARATION FABRIC PREFABRICATED BAR GRATE PLAN VIEW LIMITS OF RIP RAP (SEE END VIEW) GEOTEXTILE FABRIC 139- 11/19/19 (7.5 CM) (5 CM-12.5 CM) (30 CM) (15 CM) 6" (15 CM)2. 4. 5. 3B. 1. 3A. EROSION MATTING - SLOPE INSTALLATION 1.PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2.BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30 CM) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) APART ACROSS THE WIDTH OF THE BLANKET. 3.ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4.THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2" - 5" (5 CM - 12.5 CM) OVERLAP DEPENDING ON BLANKET TYPE. 5.CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30 CM) APART ACROSS ENTIRE BLANKET WIDTH. NOTE: *IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. STRAW WATTLE #137 06/01/15 12" WATTLE STAKE WITHIN 2' OF END OF WATTLE 2" MAX. 4' 24" MIN. 12" WOOD STAKE STRAW WATTLES WOOD STAKE, SEE DETAIL STRAW WATTLES WOOD STAKE SLOPE SURFACE TRENCH 24" MIN. GRANULAR BACKFILL CATCH BASIN CATCH BASIN - UNDERDRAIN #315 08/28/24 VARIES TEE WITH SOIL TIGHT JOINTS 4" PERFORATED TILE (SOCKED) A A PLAN VIEW SECTION A-A PIPE/CATCH BASIN EXCAVATION LIMITS 6" 6" CATCH BASIN NOTES: 1.DRAINTILE INVERTS SHALL BE PLACED AT OR ABOVE CROWN OF DOWNSTREAM PIPE. DOWNSTREAM PIPE TT FLARED END SECTION #312 08/28/24 PIPE DIAMETER D INCHES 12 15 18 21 24 27 30 33 36 42 48 54 60 FEET 8'-2'' 8'-2'' 8'-2'' 8'-2 1/2'' 8'-3'' 6'-0'' 6'-0'' 6'-0'' 6'-0'' 6'-0'' 6'-0'' 6'-0'' 6'-6'' 5380 8730 8240 6550 4100 2190 1930 1520 1280 990 740 530 LBS. PROFILE VIEW PLAN VIEW END VIEW WEIGHT SECTION PER LENGTH INCHES T 9 21 27 35 24 13 1/2 10 1/2 9 1/2 12 15 INCHES 6 9 4 A 2 2 1/4 4 1/2 6 5 1/2 5 3 3 1/2 3 3/4 4 3 1/4 2 3/4 2 1/2 INCHES 36 27 27 24 B 63 65 60 72 54 58 1/2 63 49 1/2 43 1/2 42 60 54 48 INCHES 36 30 24 W 72 84 90 78 66 96 3850 B LENGTH W D A T T D 120° TIE HOLES (TYP) 1 NOTES: 1.CONNECT CONCRETE FLARED END SECTION TO PREVIOUS PIPE SECTION USING TIE-BOLTS. 2.FOR PIPES 12" OR GREATER, END SECTIONS SHALL BE CONSTRUCTED OF RCP. 3.FOR PIPES LESS THAN 12", END SECTIONS SHALL BE CONSTRUCTED OF CMP. 18" 6" 6" 1/2" 6" 12" 18" VERTICAL FACE CURB #602-WI 10-27-17 1.0' 6" 18" 6"6" 1/2" 12 12" 1.0' MINIMUM 5" COMPACTED BASE AGGREGATE UNDER CURB MINIMUM 5" COMPACTED BASE AGGREGATE UNDER CURB CONCRETE CURB PAVING SURFACE (TYP) SEE PLANS 2" R. 2" R. REGULAR STYLE REVERSE STYLE NOTES: 1.LATERAL CONTRACTION JOINTS SHALL BE PLACED AT INTERVALS OF NOT MORE THAN 15 FEET NOR LESS THAN 6 FEET. THE JOINTS SHALL BE A MINIMUM OF 3 INCHES IN DEPTH. 2.EXPANSION JOINTS SHALL BE PLACED TRANSVERSELY AT RADIUS POINTS ON CURVES OF RADIUS 200 FEET OR LESS, AND AT ANGLE POINTS, OR AS DIRECTED BY THE ENGINEER OF RECORD. THE EXPANSION JOINTS FILLER SHALL BE A ONE PIECE FIBERBOARD OR THE APPROVED EQUIVALENT MATERIAL HAVING THE SAME DIMENSIONS AS CURB & GUTTER AT THAT STATION AND BE 0.5 INCH THICK. 3.IN ALL CASES, CONCRETE CURB & GUTTER SHALL BE PLACED ON THOROUGHLY COMPACTED CRUSHED STONE. 4.REVERSE STYLE CURB LOCATIONS ARE NOTED ON THE PLANS. CONCRETE CURB PAVING SURFACE (TYP) SEE PLANS 12" 12" 30" 6" 6" 1" 6" 12" 30" VERTICAL FACE CURB #606-WI 10-27-17 6" 6" 30" 6"6" 1" 13" 6" MINIMUM 4" COMPACTED BASE COARSE UNDER CURB MINIMUM 4" COMPACTED BASE COARSE UNDER CURB CONCRETE CURB PAVING SURFACE (TYP) SEE PLANS 3" R. 2" R. REGULAR STYLE REVERSE STYLE NOTES: 1.LATERAL CONTRACTION JOINTS SHALL BE PLACED AT INTERVALS OF NOT MORE THAN 15 FEET NOR LESS THAN 6 FEET. THE JOINTS SHALL BE A MINIMUM OF 3 INCHES IN DEPTH. 2.EXPANSION JOINTS SHALL BE PLACED TRANSVERSELY AT RADIUS POINTS ON CURVES OF RADIUS 200 FEET OR LESS, AND AT ANGLE POINTS, OR AS DIRECTED BY THE ENGINEER OF RECORD. THE EXPANSION JOINTS FILLER SHALL BE A ONE PIECE FIBERBOARD OR THE APPROVED EQUIVALENT MATERIAL HAVING THE SAME DIMENSIONS AS CURB & GUTTER AT THAT STATION AND BE 0.5 INCH THICK. 3.IN ALL CASES, CONCRETE CURB & GUTTER SHALL BE PLACED ON THOROUGHLY COMPACTED CRUSHED STONE. 4.REVERSE STYLE CURB LOCATIONS ARE NOTED ON THE PLANS. CONCRETE CURB PAVING SURFACE (TYP) SEE PLANS 3" R. 2" R. 24" 24" TAPER CURB HEAD #623 10-11-12 1" 4' NOTES: 1.CONTRACTION JOINTS SHALL BE PLACED EVERY 10 FEET 2.EXPANSION JOINTS (3/4" EXPANSION FIBER MATERIAL) SHALL BE PLACED EVERY 300 FEET AND AT EVERY PC/PT AND 3 FEET FROM STRUCTURES CONTRACTION JOINT 1" ROUNDED EDGE ADA SIGN #706 10-11-12 VAN ACCESSIBLE RESERVED PARKING VEHICLES WITH VET OR DISABLED PLATES OR STATE DISABLED CARD THIS SPACE PROVIDE VAN-ACCESSIBLE SIGN AT VAN-ACCESS LOCATIONS 2" DIAMETER GALVANIZED STEEL POST 8" DIAMETER BY 3'-6" DEEP CONCRETE BASE GRADE 1.0' 1.50'5.0' HANDICAP PARKING SIGN SHALL CONFORM TO CITY STANDARDS CONCRETE SIDEWALK #507 10-11-12 SLOPE PROPOSED GRADE 5" THICK CONCRETE SIDEWALK 2% MAXIMUM EARTH (TYP.) 4" COMPACTED BASE MATERIALEXTEND BASE MATERIAL 6" MIN BEYOND EDGE OF CONCRETE (TYP.) TOPSOIL BACKFILL PROPOSED GRADE EXISTING GRADE 140- 11/19/19 CRITICAL POINTS A. OVERLAPS AND SEAMS B. PROJECTED WATER LINE C. CHANNEL BOTTOM/SIDE SLOPE VERTICES * HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL POINTS ALONG THE CHANNEL SURFACE. ** IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 cm) MAY (30 CM) (15 CM) 6" (15 cm) (15 CM) 6" (10 CM - 15 CM) (10 CM) 6" NOTE: BE NECESSARY TO PROPERLY ANCHOR THE BLANKETS. (5 CM - 12.5 CM) 1. 6. 7. 2. 5. 4. 8. 3. (15 CM) 6" EROSION MATTING - CHANNEL INSTALLATION 1.PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2.BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH WITH APPROXIMATELY 12" (30 CM) OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMAPCT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30 CM) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) ACROSS THE WIDTH OF THE BLANKET. 3.ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4.PLACE CONSECUTIVE BLANKETS END OVER END (SHINGLE STYLE) WITH A 4" - 6" (10 CM -15 CM) OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10 CM) APART AND 4" (10 CM) ON CENTER TO SECURE BLANKETS. 5.FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM) APART IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 6.ADJACENT BLANKETS MUST BE OVERLAPPED APPROXIMATELY 2" - 5" (5 CM -12.5 CM) (DEPENDING ON BLANKET TYPE) AND STAPLED. 7.IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT (9 M - 12 M) INTERVALS. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10 CM) APART AND 4" (10 CM) ON CENTER OVER ENTIRE WIDTH OF THE CHANNEL. 8.THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM) APART IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. NOTE: * IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE NECESSARY TO PROPERLY ANCHOR THE BLANKETS. INTEGRAL CURB AND SIDEWALK #617 12-28-12 SLOPE 12" 18" 4" SURFACE COURSE BINDER COURSE ROUND NOSE (1" R MAX.) VARIES EXTEND GRAVEL BASE 6" PAST CONCRETE COMPACTED GRANULAR BACKFILL CONCRETE SIDEWALK 5" 4.0" 2.5" #4 REBAR PLACED 3 INCHES INTO CURB 6x6 WELDED WIRE FABRIC OR FIBER MESH DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2025 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONSSHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI CONSTRUCTION DETAILS.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 C-21 DFL TGM TGM CONSTRUCTION DETAILS 1CITY COMMENTS11/09/26C-21 N.T.S. CONSTRUCTION DETAILS FRANKLIN SIX SIBS FLOW TOP SLAB BOTTOM TO BE SMOOTH AND LEVEL IN ENTIRE MANHOLE IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT THE VILLAGE/CITY BUILDING INSPECTION DEPARTMENT PRIOR TO THE START OF CONSTRUCTION TO VERIFY EXACT SAMPLING MANHOLE REQUIREMENTS. 6" MONOLITHIC CONCRETE COLLAR 9" TRANSITION DISCHARGE OUTLET TO BE SQUARE AT MANHOLE WALL. HEIGHT & WIDTH TO BE SAME AS DIA. OF SEWER GROOVE 1" WIDE & 1" DEEP IN SIDES OF BENCH #6 EACH CORNER BOTTOM FACE PROVIDE EXTERNAL WATERTIGHT FRAME /CHIMNEY SEAL MH STEPS 15" O.C. SAMPLING AND GAUGING MANHOLE #403 01/28/13 1.0'9" VARIABLE CAST IN PLACE CONCRETE VARIABLE 8" TO 24"1.0' 1/2" STRAIGHT VERTICAL WALL 3.0' DIA. 9" 4.0' 9" BENCH ON BOTH SIDES #5 @ 12" C/C (EW) ADJUSTING RINGS SEE CITY OF NEW BERLIN STANDARD SPECIFICATIONS AA #5 @ 12" C/C (E/W) 2.0' DIA. 4.0' 6" 1" 1" 4.0' 3" CLEAR NOTES: 1.4'-0" I.D. PRECAST MAY BE SUBSTITUTED FOR SAMPLING M.H.'S ON BUILDING LATERAL 2.4'-0" I.D. MONOLITHIC MAY BE SUBSTITUTED FOR GAUGING M.H.'S ON MUNICIPAL SEWERS DIA. OFSEWER FIRE HYDRANT #501 10-10-12 ANCHOR TEE & VALVE ASSEMBLY WITH SCREW TO VALVE BOX CONCRETE BUTTRESS (MAY BE FIELD MIX) MECHANICAL JOINT RESTRAINT OR TIE RODS C/L HYDRANT BRANCH WOOD BLOCKING 34" LIMESTONE CHIPS CONCRETE BUTTRESS (MAY BE FIELD MIX) CRUSHED STONE C/L OF MAIN WATER VARIABLE 8.0' MIN. 2" MIN. BOTTOM OF FLANGE TO EXISTING GRADE 2.0' SUMP NOTES: 1.MEGALUG RESTRAINING GLANDS ON ALL MECHANICAL JOINTS, THE BOLTS & NUTS ARE TO BE HIGH STRENGTH LOW ALLOY STEEL (CORTEN) AS PER SECTION 11.6.5 OF A.W.W.A. C-111. 2.THE FOLLOWING HYDRANTS SHALL BE ALLOWED: MUELLER SUPER CENTURION 250 3-WAY FIRE HYDRANT U.S. PIPE METROPOLITAN / M-94 DUCTILE IRON FIRE HYDRANT WATEROUS 514" PACER FIRE HYDRANT THRUST BLOCK #502 10-10-12 PLAN 45° BEND 6" SIZE PIPE 24" 20" 16" 12" 30" 8" A B3 1-'2" A3 1-'4" B2 1-'0" 90° BENDS 2'-3" 2'-10" 3'-4" 3'-10" 4'-8" 6'-4" 5'-0" 2'-8" 3'-3" 2'-4" 2'-10" 1'-10" 8'-0" 3'-10" 3'-10" 1'-6" 1'-10" 1'-2" A2 B1 1-'0" A1 22 1/2° BENDS 1'-4" 1'-8" 2'-0" 2'-4" 3'-0" 1'-0" 45° BENDS 1-'0" 1'-4" 1'-10" 2'-6" 3'-3" 4'-0" 5'-4" PLAN 90° BEND SECTION A-A 1-'0" 1'-4" 1'-10" 2'-4" 2'-10" 3'-6" 1'-0" NOTES: 1.PROVIDE THRUST BLOCKING TO PREVENT MOVEMENT OF LINES UNDER PRESSURE AT BENDS, TEES, CAPS, VALVES, HYDRANTS, AND AT POINTS SPECIFIED BY THE ENGINEER 2.ALL BLOCKING SHALL BE WITH POURED CLASS SI CONCRETE AGAINST UNDISTURBED VERTICAL EARTH SURFACE 3.THRUST BLOCKS TO BE AT ALL BENDS 1114° OR GREATER 4.THE COST OF INSTALLING THE THRUST BLOCK SHALL BE INCIDENTAL TO THE CONSTRUCTION OF THE WATER 5.DIMENSION A2 & A3 SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERING WITH M.J BOLTS B2 A2 B3 A3 CLASS "F" CONCRETE (4.5 BAG MIX) BUTTRESS TO BE POURED AGAINST FIRM UNDISTURBED EARTH 90° CONCRETE SHALL BE IN CONTACT WITH THIS QUADRANT OF PIPE AT LEAST BEDDING MATERIAL APPROX. 1:1 SLOPE WHERE BEDDING DEPTH BELOW PIPE EXCEEDS 6" A 5 5 BOLLARD #801 6/26/13 CONCRETE WASH (TYP.) 1" 5.0' (EXTERIOR) 4.0' (INTERIOR)4.0'6" 1.5' 8" DIA. CONCRETE FILLED STEEL PIPE BUMPER- SEE PLANS FOR LOCATION (PAINT) 1" CONCRETE WASH (TYP.) FINISHED PAVEMENT 1.5' POURED CONCRETE BASE ADA PARKING STRIPING #713 2/20/15 ADA PARKING SIGN 5.0' MAX CONCRETE SIDEWALK PRECAST CONCRETE WHEEL STOP (VERIFY MUNICIPALITY ACCEPTANCE) DEPRESSED CURB & GUTTER) 4" WIDE YELLOW PAINT 16.0' MIN.8.0' MIN. 8.0' MIN (VAN ACCESSIBLE) UNIVERSAL ADA SYMBOL INLET #302 10-04-12 NOTES: 1.EASY STICK, RUBBER GASKET OR APPROVED EQUIVALENT SHALL BE PLACED AT ALL JOINTS BETWEEN ADJUSTING RINGS FOR STORM CATCH BASINS. 2.THE FLAT TOP MAY BE USED IN LIEU OF THE TAPERED TOP WHEN FIELD CONDITIONS PROHIBIT USE OF A TAPERED TOP. 3.STRUCTURE TO BE 4.0' DIA. OR AS INDICATED ON THE PLANS. CEMENT MORTAR 6" PRECAST, REINF'D CONC. TOP INSTALL STEPS @ 16'' O.C. WHEN STRUCTURE IS OVER 5 FEET DEEP. (ALIGN WITH OPENING) SEE PLAN FOR SEWER SIZE AND INVERT ELEV. GRADE ADD ADJUSTING RINGS IF NEEDED 5" PRECAST CONC. WALLS REINF'D CONCRETE FOUNDATION W/ #5 RE-BAR @ 12'' EA. WAY. 8" MIN. 2.0' 4.0' NEENAH FOUNDRY R-2502, TYPE D GRATE, UNLESS OTHERWISE NOTED ON THE PLANS STORM INLET - CURB #305 10-10-12 GRADE/TOP OF CURB CL 2.0' 4.0' 8" MIN. NEENAH FOUNDRY R-3067 FRAME WITH TYPE R GRATE FOR STRUCTURES IN VERTICAL CURB. NEENAH R-3339 FRAME AND GRATE FOR STRUCTURES IN DEPRESSED CURB UNLESS OTHERWISE NOTED ON PLANS TAPER CURB & GUTTER 5' EACH SIDE OF STRUCTURE TO MATCH WIDTH OF FRAME AT CATCH BASIN CEMENT MORTAR ADD ADJUSTMENT RINGS AS NEEDED PER STD SPECS 6" PRECAST, REINF'D CONC. TOP INSTALL STEPS @ 16" O.C. WHEN STRUCTURE IS OVER 5 FEET DEEP. (ALIGN WITH OPENING) SEE PLAN FOR SEWER SIZE AND INVERT ELEVATION REINF'D CONCRETE FOUNDATION W/ #5 REBAR @ 12" EA. WAY 5" PRECAST CONC. WALLS NOTES: 1.EASY STICK, RUBBER GASKET OR APPROVED EQUIVALENT SHALL BE PLACED AT ALL JOINTS BETWEEN ADJUSTING RINGS FOR STORM CATCH BASINS. 2.THE FLAT TOP MAY BE USED IN LIEU OF THE TAPERED TOP WHEN FIELD CONDITIONS PROHIBIT USE OF A TAPERED TOP. 3.STRUCTURES TO BE 4' DIA. OR AS INDICATED ON THE PLANS. HYDRANT BOLLARD #503 10-10-12 ELEVATION PLAN FIRE HYDRANT NOTES: 1.USE WHERE HYDRANT IS LOCATED WITHIN PAVED AREAS, COST INCIDENTAL. 2.0'2.0' 2.0'2.0' 6" DIA STANDARD PIPE FILLED WITH CONCRETE AND PAINTED YELLOW (4 REQUIRED) SLOPED TOP ASPHALT PAVEMENT 18" DIA. CONCRETE BASE #6 - 14" LONG REBAR EACH WAY THRU PIPE 1"4.0'5.0' 2" MIN 9" LC BEHIND CURB DRAIN TILE OUTLET REMOVE DENSE GRADED BASE MATERIAL BEHIND CURB AT OUTLET POINT. REPLACE WITH DRAIN TILE BACKFILL MATERIAL 3-IN OF TOPSOIL ABOVE DRAIN TILE EXTEND DUAL WALL DRAIN TILE 2-FT PAST BACK OF CURB AS PART OF UNDER PAVEMENT DRAIN TILE INSTALL BEHIND CURB DRAIN TILE WISDOT NO. 1 GRADATION WASHED STONE SURROUNDED ON ALL SIDES WITH TYPE SAS FILTER FABRIC PREFAB. 90° PREFAB. TEE DRAIN TILE GENERAL SPECIFICATIONS 1.THE DRAIN TILE CONDUIT AND FITTINGS SHALL MEET STRENGTH AND DURABILITY REQUIREMENTS FOR THE SITE. ALL CONDUITS AND FITTINGS SHALL MEET OR EXCEED THE MINIMUM REQUIREMENTS OF THE APPROPRIATE SPECIFICATIONS PUBLISHED BY THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. CORRUGATED HIGH DENSITY POLYETHYLENE (HDPE) CONDUIT AND FITTINGS SHALL MEET THE REQUIREMENTS OF ASTM M252. CONDUIT TYPE (SINGLE WALL OR DUAL WALL) SHALL INSTALLED PER THE LOCATIONS SHOWN IN THE PLANS. CONTRACTOR MAY SUBSTITUTE DUAL WALL CONDUIT AT LOCATIONS SPECIFIED FOR SINGLE WALL CONDUIT AT THE SOLE EXPENSE OF THE CONTRACTOR. ·SINGLE WALL CONDUIT SHALL BE TYPE CP WITH CLASS II PERFORATION PATTERN. ·DUAL WALL CONDUIT SHALL BE TYPE SP WITH A SMOOTH INTERIOR THAT CARRIES A MAXIMUM MANNING'S “N” VALUE OF 0.12 WITH CLASS II PERFORATION PATTERN. 2.ALL DRAIN TILE CONSTRUCTION MUST BE PROVIDED WITH TRACER WIRE OR OTHER APPROVED METHODS IN ORDER TO BE LOCATED IN ACCORD WITH 182.0715(2R) OF THE STATUTES. CONTRACTOR SHALL PROVIDE THE ENGINEER NOTICE OF LOCATION METHOD PRIOR TO THE START OF CONSTRUCTION. 3.A MAXIMUM TRENCH WIDTH OF 2-FT SHALL BE MAINTAINED FOR ALL DRAIN TILE INSTALLATION WITH THE EXCEPTION OF CONNECTION POINTS TO THE EXISTING STORM SEWER SYSTEM IN WHICH CASE THE CONTRACTOR SHALL LIMIT DISTURBANCE AS POSSIBLE. 4.THE MINIMUM DEPTH OF COVER (FINISH GRADE TO TOP PIPE) SHALL BE: ·CONCRETE PAVED AREAS - 2.0-FT ·ASPHALT PAVED AREAS - 2.5-FT ·BEHIND CURB - 0.5-FT ·OTHER LANDSCAPED/GRASS/PERVIOUS AREAS - 2.0-FT 5. CONNECTION TO THE EXISTING STORM SEWER SYSTEM SHALL ACHIEVED BY CORING THE EXISTING REINFORCED CONCRETE STORM SEWER STRUCTURES OR PIPING TO THE DIAMETER NECESSARY TO ACCOMMODATE A PERMANENT CONNECTION. ALL CONNECTIONS TO THE EXISTING REINFORCED CONCRETE STORM SEWER SHALL BE ACHIEVED BY THE USE OF KOR-N-SEAL CONNECTORS, OR EQUAL. 6.FOR TRENCH INSTALLATIONS OF CORRUGATED PLASTIC CONDUIT (OTHER THAN BEHIND CURB LOCATIONS), THE FOLLOWING BEDDING METHODS ARE REQUIRED: ·A STONE BEDDING LAYER, AT LEAST 3 IN. THICK, USING A CLEAR STONE SHALL BE INSTALLED TO PROVIDE CONDUIT SUPPORT. ·COMPACT BEDDING MATERIAL BESIDE AND TO THE UPPER (TOP) LIMITS OF BASE COURSE IN PAVED AREAS OR TOP OF CLAY (BOTTOM OF TOPSOIL LAYER) ABOVE THE CONDUIT.. 7.ANY HARD OBJECTS LARGER THAN 1.5 IN. IN DIAMETER EXPOSED WITHIN THE TRENCH BOTTOM OR WALLS SHALL BE REMOVED TO PREVENT UNDUE STRESSES ON THE CONDUIT AND FITTINGS. 8.PRE MANUFACTURED FITTINGS (SUCH AS: WYES, TEES, BENDS, CAPS, ETC) OF THE SAME MATERIAL AS THE CONDUIT SHALL BE USED AT ALL CONNECTIONS AND DEFLECTIONS GREATER THAN 22.5 DEGREES. 9.IF NOT CONNECTED TO A STRUCTURE, THE UPPER END OF EACH SUBSURFACE DRAIN TILE SHALL BE CAPPED WITH A TIGHT-FITTING EXTERNAL CAP OF THE SAME MATERIAL AS THE CONDUIT. 10.AT ALL TIMES THE DRAIN TILE SYSTEM SHALL BE KEPT CLEAN AND PROTECTED AGAINST UNDERMINING OF THE CAPACITY OF THE CONDUIT AND DAMAGE DURING CONSTRUCTION. TYPICAL CAPACITY UNDERMINING INCLUDES ENTRY OF CONSTRUCTION MATERIALS, TRASH, AND RODENTS INTO THE CONDUIT. 4-IN DUAL WALL PERFORATED DRAIN TILE. EXTEND NO. 1 STONE TO BOTTOM OF BASE COURSE LAYER PIPE SECTION 6-IN COMPACTED CLAY ABOVE DRAIN TILE DRAINTILE 3-IN OF TOPSOIL ABOVE DRAIN TILE 6-IN COMPACTED CLAY ABOVE DRAIN TILE 3-IN OF TOPSOIL ABOVE DRAIN TILE 1-FT MIN PERVIOUS AREA DRAIN TILE 3-IN OF TOPSOIL ABOVE DRAIN TILE 6-IN COMPACTED CLAY ABOVE DRAIN TILE PAVEMENT TYPE VARIES 1-FT MIN EDGE OF PAVEMENT DRAIN TILE E E E SOUTH LINE OF THE NW 1/4 SEC. 36, T5N, R21E S88°36'18"W 2631.37' 30' 725 724 721 720 719 718 717 716 715 714 713 712 710 705 705 705 705 705 704 703 702 714 713 715 715 715 715 715 710 TREELINE TREELINE TREELINE ASPHALT PAVEMENT S S S S D D S DD 714 715 715715 715 715 718 717 716 715 714 715 717 716 718 721 723 40.9' 703 705 707 710 713 714 713 713 ((R) S88°36'13"W CSM 9260) EAST LINE OF THE NW 1/4 SEC. 36, T5N, R21E EDGE OF ICE ELEV=700.83 POND 712 709 708 707 706 704705 702703 701 711 710 709 708 707706705705 716717 718 714 712 713 711 711 712 713 713 714 714 713 713 712 714 712713 712 713 715 714 714 713 713 717 716 717 715 706707708 708 707708 706 704 703 702 701 716 714713 716 717 713 714 715 715 714 715 717 717 716 717 716 716 716 716 716 716 718 719 721 717 718719 720 721 722 718719 720 718719718 718 719 716 717 718 719 717 716 715 717 716 715 714 713 714 715 716 717717 716 715 714 713 713 713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 715 716 717 713 714 715 717 716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717 714 713 715 714 713 712 711 711712 713 716715714713712 716 717 717 716 715 714 713712 716 717 717716 715 714713 712 716 716 716 717 716715 716 717 717 717 717 717 717 717 717 717 712 714 713 716 717 716 717 717717 704705706707708709710711712713714715 717716 716 723 721 722 715 716 717 715 716 717 714710706 711 710 709 712 713 714 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.DD.I.D D.I.D D.I.D D.I.D D.I.D SYMBOL CODE DESCRIPTION QTY SNOW STORAGE AREAS 25,223 sf1 REFERENCE NOTES SCHEDULE NORTH 1" = 60'0 120' GRAPHICAL SCALE (FEET) DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB TREE OVERVIEW & SNOW STORAGE AREAS 1 CITY COMMENTS 11/09/26 L-1 1"=60' TREE OVERVIEW & SNOW STORAGE AREAS FRANKLIN SIX SIBS SYMBOL QTY BOTANICAL NAME COMMON NAME SIZE REMARKS TREES 15 DECIDUOUS TREE Acer saccharum 'Legacy' Legacy Sugar Maple 3" Cal. 60' T x 50' W Celtis occidentalis `Chicagoland` Chicagoland Hackberry 3" Cal. 50` T x 40` W Gleditsia triacanthos inermis `Shademaster` Shademaster Locust 3" Cal. 60` T x 50` W Ulmus x `Frontier` Frontier Elm 3" Cal. 45` T x 30` W 22 ORNAMENTAL TREE Amelanchier arborea Downy Serviceberry 3" Cal. 20` T x 20` W Maackia amurensis Amur Maackia 3" Cal. 25' T x 25' W Magnolia x `Butterflies` Butterflies Magnolia 3" Cal. 17` T x 12` W 22 EVERGREEN TREE Pinus cembra Swiss Stone Pine 7` Tall 35` T x 15` W Pinus strobus Eastern White Pine 7` Tall 60` T x 30` W Thuja occidentalis 'Hetz Wintergreen' Wintergreen Arborvitae 7` Ht. 25` T x 10` W 19 STREET TREES Gymnocladus dioicus Kentucky Coffee Tree 3" Cal. 50' T x 50' W Quercus x schuetti Swamp Bur Oak 3" Cal. 70' T x 65' W Tilia tomentosa 'Sterling' Sterling Silver Linden 3" Cal. 50' T x 40' W Ulmus x 'New Horizon' New Horizon Elm 3" Cal. 50' T x 40' W SHRUBS 32 MEDIUM EVERGREEN SHRUB Juniperus chinensis `J.N. Select Blue` Star Power Juniper 4` Ht. 16` T x 8` W Thuja occidentalis `Nigra` Dark Green Arborvitae 4` Ht. 20' T x 8' W Tsuga canadensis `Gentsh White` Gentsh White Hemlock 4` Ht. 8' T x 6' W 42 SMALL EVERGREEN SHRUB Juniperus chinensis `Old Gold` Old Gold Juniper 2` Wide 3` T x 5` W Picea abies `Nidiformis` Nest Spruce 2` Wide 3` T x 5` W Thuja occidentalis `Hetz Midget` Hetz Midget Arborvitae 2` Wide 3` T x 3` W 15 SMALL DECIDUOUS SHRUB Aronia arbutifolia `Brilliantissima` Brilliant Red Chokeberry 3 gal. 7' T x 6' W Forsythia viridissima `Bronxensis` Bronx Forsythia 2 gal. 3' T x 4' W Hypericum kalmianum Kalm St. Johnswort 3 gal. 3' T x 3' W 96 TALL ORNAMENTAL GRASS Andropogon gerardii 'Blackhawks' Blackhawks Big Bluestem 1 gal. 48" T x 30" W Panicum virgatum 'Cheyenne Sky' Cheyenne Sky Prairie Winds® Switch Grass 1 gal. 24" T x 18" W Panicum virgatum `Heavy Metal` Blue Switch Grass 1 gal. 4` T x 3` W 16 MEDIUM DECIDUOUS SHRUB Cornus sericea `Baileyi` Red Twig Dogwood 5 gal. 8' T x 8' W Cotoneaster multiflorus Showy Cotoneaster 5 gal. 8' T x 12' W Viburnum dentatum deamii 'SMVDBL' All That Glows Arrowwood Viburnum 5 gal. 5' T x 5' W 119 SHORT ORNAMENTAL GRASS Pennisetum alopecuroides 'Burgundy Bunny' Burgundy Bunny Dwarf Fountain Grass 1 gal. 12" T x 18" W Schizachyrium scoparium 'Chameleon' Chameleon Little Bluestem 1 gal. 24" T x 20" W Sporobolus heterolepis Prairie Dropseed 1 gal. 18` T x 18" W SHRUB AREAS 368 sf PERENNIALS VARIOUS SPECIES 1 gal. TURF 60,596 sf Turf Drought Tolerant Fescue Blend seed 50,286 sf Turf Low Grow Reinders No Mow/Low Grow Mix seed PLANT SCHEDULE 1 1 CONSERVATION EASEMENT 1 1 SHEET L-2A SHEET L-2B SHEET L-2C SHEET L-2D OVERHEAD UTILITY EASEMENT OVERHEAD UTILITY EASEMENT BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE PAVED AREA 244,469 SF 10% 0.10 REQ. SNOW STORAGE 24,446.9 SFX = 712 710 705 D D 709 708 707 706 705 711 710 709 708 707706705 705 715 714 713 712 711 716 715 714 713 712 716 717 717 716 716 717 717 716 715 714 713 712 716 716 716 717 716 715 717 716 717 717717 704 705 706 707 708 709 710 711 712 713 714 715 E E S 715 717 716 718 718 719 716 717 718 719 717 716 715 714 715 715 716 717 717 W W E 716 715 717 716 715 717 716 715 714 713 714 715 716 717717 716 715 714 713 713 713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 716 713 714 715 717 716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717 714 717 716 D.I.D D.I.D D.I.DD.I.D D.I.D D.I.D D.I.D D.I.D W W E S S D 715 715 716 715 714 716 717 716 715 716 717 717 716 W NORTH 1" = 30'0 60' GRAPHICAL SCALE (FEET) DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB TREE ENLARGEMENT 1 CITY COMMENTS 11/09/26 L-2 1" = 30' TREE ENLARGEMENT FRANKLIN SIX SIBS ENLARGEMENT L-2B SCALE: 1"=30' ENLARGEMENT L-2A SCALE: 1"=30' ENLARGEMENT L-2C SCALE: 1"=30' ENLARGEMENT L-2D SCALE: 1"=30' SYMBOL BOTANICAL NAME COMMON NAME TREES DECIDUOUS TREE Acer saccharum 'Legacy' Legacy Sugar Maple Celtis occidentalis `Chicagoland` Chicagoland Hackberry Gleditsia triacanthos inermis `Shademaster` Shademaster Locust Ulmus x `Frontier` Frontier Elm ORNAMENTAL TREE Amelanchier arborea Downy Serviceberry Maackia amurensis Amur Maackia Magnolia x `Butterflies` Butterflies Magnolia EVERGREEN TREE Pinus cembra Swiss Stone Pine Pinus strobus Eastern White Pine Thuja occidentalis 'Hetz Wintergreen' Wintergreen Arborvitae STREET TREES Gymnocladus dioicus Kentucky Coffee Tree Quercus x schuetti Swamp Bur Oak Tilia tomentosa 'Sterling' Sterling Silver Linden Ulmus x 'New Horizon' New Horizon Elm SHRUBS MEDIUM EVERGREEN SHRUB Juniperus chinensis `J.N. Select Blue` Star Power Juniper Thuja occidentalis `Nigra` Dark Green Arborvitae Tsuga canadensis `Gentsh White` Gentsh White Hemlock SMALL EVERGREEN SHRUB Juniperus chinensis `Old Gold` Old Gold Juniper Picea abies `Nidiformis` Nest Spruce Thuja occidentalis `Hetz Midget` Hetz Midget Arborvitae SMALL DECIDUOUS SHRUB Aronia arbutifolia `Brilliantissima` Brilliant Red Chokeberry Forsythia viridissima `Bronxensis` Bronx Forsythia Hypericum kalmianum Kalm St. Johnswort TALL ORNAMENTAL GRASS Andropogon gerardii 'Blackhawks' Blackhawks Big Bluestem Panicum virgatum 'Cheyenne Sky' Cheyenne Sky Prairie Winds® Switch Grass Panicum virgatum `Heavy Metal` Blue Switch Grass MEDIUM DECIDUOUS SHRUB Cornus sericea `Baileyi` Red Twig Dogwood Cotoneaster multiflorus Showy Cotoneaster Viburnum dentatum deamii 'SMVDBL' All That Glows Arrowwood Viburnum SHORT ORNAMENTAL GRASS Pennisetum alopecuroides 'Burgundy Bunny' Burgundy Bunny Dwarf Fountain Grass Schizachyrium scoparium 'Chameleon' Chameleon Little Bluestem Sporobolus heterolepis Prairie Dropseed SHRUB AREAS PERENNIALS VARIOUS SPECIES TURF Turf Drought Tolerant Fescue Blend Turf Low Grow Reinders No Mow/Low Grow Mix PLANT KEY SHEET L-2D SHEET L-2C SHEET L-2D SHEET L-2C SHEET L-2D SHEET L-2B SHEET L-2C SHEET L-2A SHEET L-2D SHEET L-2B SHEET L-2C SHEET L-2A CONSERVATION EASEMENT BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE E E E SOUTH LINE OF THE NW 1/4 SEC. 36, T5N, R21E S88°36'18"W 2631.37' 725 724 721 720 719 718 717 716 715 714 713 712 710 705 705 705 705 705 704 703 714 715 715 715 715 715 710 TREELINE TREELINE TREELINE ASPHALT PAVEMENT S S S S D D S 714 715 715715 715 715 717 716 715 714 715 717 716 718 721 723 40.9' 705 707 710 713 714 713 713 ((R) S88°36'13"W CSM 9260) EAST LINE OF THE NW 1/4 SEC. 36, T5N, R21E EDGE OF ICE ELEV=700.83 POND 709 708 707 706 704705 702703 701 711 710 709 708 707706705705 716717 718 714 712 713 711 711 712 713 713 714 714 713 713 712 714 712713 712 713 715 714 714 713 713 717 716 717 706707708 708 707708 706 704 703 702 701 716 714713 716717 713 714 715 715 714 715 717 717 716 717 716 716 716 716 716 716 718 719 721 717 718719 720 721 722 718719 720 718719718 718 719 716 717 718 719 717 716 715 717 716 715 714 713 714 715 716 717717 716 715 714 713 713 713 717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 713 712 712 712 712 712 712 713 714 715 716 717 713 714 715 716 717 713 714 715 715 716 717 713 714 715 717 716 713 713 714 715 716 717 713 713 715 714 716 714 715 716 717 714 713 715 714 713 712 711 711712 713 716715714713712 716 717 717 716 715 714 713712 716 717 717716 715 714713 712 716 716 716 717 716715 716 717 717 717 717 717 717 717 717 717 712 714 713 716 717 716 717 717717 704705706707708709710711712713714715 717716 716 723 721 722 711 710 709 712 713 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D D.I.D NORTH 1" = 60'0 120' GRAPHICAL SCALE (FEET) DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB SHRUB OVERVIEW 1 CITY COMMENTS 11/09/26 L-3 1"=60' SHRUB OVERVIEW FRANKLIN SIX SIBS SHEET L-4 SHEET L-5 CONSERVATION EASEMENT BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE BLEND TURF THROUGH LINE OF DISTURBANCE 714 713 712 716 717 713 716 717 715 716 717 715 717 716 713 715 716 717 713 715 716 716 717 717 717 716 716 716 717 717 717 717 717717 PROPOSED BUILDING A 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.D D.I.D D.I.D NORTH 1" = 20'0 40' GRAPHICAL SCALE (FEET) DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB SHRUB ENLARGEMENT 1 CITY COMMENTS 11/09/26 L-4 1"=20' SHRUB ENLARGEMENT FRANKLIN SIX SIBS ENLARGEMENT L-4 SCALE: 1"=20' SYMBOL BOTANICAL NAME COMMON NAME TREES DECIDUOUS TREE Acer saccharum 'Legacy' Legacy Sugar Maple Celtis occidentalis `Chicagoland` Chicagoland Hackberry Gleditsia triacanthos inermis `Shademaster` Shademaster Locust Ulmus x `Frontier` Frontier Elm ORNAMENTAL TREE Amelanchier arborea Downy Serviceberry Maackia amurensis Amur Maackia Magnolia x `Butterflies` Butterflies Magnolia EVERGREEN TREE Pinus cembra Swiss Stone Pine Pinus strobus Eastern White Pine Thuja occidentalis 'Hetz Wintergreen' Wintergreen Arborvitae STREET TREES Gymnocladus dioicus Kentucky Coffee Tree Quercus x schuetti Swamp Bur Oak Tilia tomentosa 'Sterling' Sterling Silver Linden Ulmus x 'New Horizon' New Horizon Elm SHRUBS MEDIUM EVERGREEN SHRUB Juniperus chinensis `J.N. Select Blue` Star Power Juniper Thuja occidentalis `Nigra` Dark Green Arborvitae Tsuga canadensis `Gentsh White` Gentsh White Hemlock SMALL EVERGREEN SHRUB Juniperus chinensis `Old Gold` Old Gold Juniper Picea abies `Nidiformis` Nest Spruce Thuja occidentalis `Hetz Midget` Hetz Midget Arborvitae SMALL DECIDUOUS SHRUB Aronia arbutifolia `Brilliantissima` Brilliant Red Chokeberry Forsythia viridissima `Bronxensis` Bronx Forsythia Hypericum kalmianum Kalm St. Johnswort TALL ORNAMENTAL GRASS Andropogon gerardii 'Blackhawks' Blackhawks Big Bluestem Panicum virgatum 'Cheyenne Sky' Cheyenne Sky Prairie Winds® Switch Grass Panicum virgatum `Heavy Metal` Blue Switch Grass MEDIUM DECIDUOUS SHRUB Cornus sericea `Baileyi` Red Twig Dogwood Cotoneaster multiflorus Showy Cotoneaster Viburnum dentatum deamii 'SMVDBL' All That Glows Arrowwood Viburnum SHORT ORNAMENTAL GRASS Pennisetum alopecuroides 'Burgundy Bunny' Burgundy Bunny Dwarf Fountain Grass Schizachyrium scoparium 'Chameleon' Chameleon Little Bluestem Sporobolus heterolepis Prairie Dropseed SHRUB AREAS PERENNIALS VARIOUS SPECIES TURF Turf Drought Tolerant Fescue Blend Turf Low Grow Reinders No Mow/Low Grow Mix PLANT KEY 720 719 718 717 716 717 716 716 716 717 716 718 717 716 715 714 715 716 717717 716 715 714 713 713 717 716 715 714 713 717 716 715 714 717 716 715 717 717 717 717 717 717 PROPOSED BUILDING B 128,000 SF | FFE=717.30 SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION D.I.D D.I.DD.I.DD.I.D NORTH 1" = 20'0 40' GRAPHICAL SCALE (FEET) DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB SHRUB ENLARGEMENT 1 CITY COMMENTS 11/09/26 L-5 1"=20' SHRUB ENLARGEMENT FRANKLIN SIX SIBS ENLARGEMENT L-5 SCALE: 1"=20' SYMBOL BOTANICAL NAME COMMON NAME TREES DECIDUOUS TREE Acer saccharum 'Legacy' Legacy Sugar Maple Celtis occidentalis `Chicagoland` Chicagoland Hackberry Gleditsia triacanthos inermis `Shademaster` Shademaster Locust Ulmus x `Frontier` Frontier Elm ORNAMENTAL TREE Amelanchier arborea Downy Serviceberry Maackia amurensis Amur Maackia Magnolia x `Butterflies` Butterflies Magnolia EVERGREEN TREE Pinus cembra Swiss Stone Pine Pinus strobus Eastern White Pine Thuja occidentalis 'Hetz Wintergreen' Wintergreen Arborvitae STREET TREES Gymnocladus dioicus Kentucky Coffee Tree Quercus x schuetti Swamp Bur Oak Tilia tomentosa 'Sterling' Sterling Silver Linden Ulmus x 'New Horizon' New Horizon Elm SHRUBS MEDIUM EVERGREEN SHRUB Juniperus chinensis `J.N. Select Blue` Star Power Juniper Thuja occidentalis `Nigra` Dark Green Arborvitae Tsuga canadensis `Gentsh White` Gentsh White Hemlock SMALL EVERGREEN SHRUB Juniperus chinensis `Old Gold` Old Gold Juniper Picea abies `Nidiformis` Nest Spruce Thuja occidentalis `Hetz Midget` Hetz Midget Arborvitae SMALL DECIDUOUS SHRUB Aronia arbutifolia `Brilliantissima` Brilliant Red Chokeberry Forsythia viridissima `Bronxensis` Bronx Forsythia Hypericum kalmianum Kalm St. Johnswort TALL ORNAMENTAL GRASS Andropogon gerardii 'Blackhawks' Blackhawks Big Bluestem Panicum virgatum 'Cheyenne Sky' Cheyenne Sky Prairie Winds® Switch Grass Panicum virgatum `Heavy Metal` Blue Switch Grass MEDIUM DECIDUOUS SHRUB Cornus sericea `Baileyi` Red Twig Dogwood Cotoneaster multiflorus Showy Cotoneaster Viburnum dentatum deamii 'SMVDBL' All That Glows Arrowwood Viburnum SHORT ORNAMENTAL GRASS Pennisetum alopecuroides 'Burgundy Bunny' Burgundy Bunny Dwarf Fountain Grass Schizachyrium scoparium 'Chameleon' Chameleon Little Bluestem Sporobolus heterolepis Prairie Dropseed SHRUB AREAS PERENNIALS VARIOUS SPECIES TURF Turf Drought Tolerant Fescue Blend Turf Low Grow Reinders No Mow/Low Grow Mix PLANT KEY SOIL PLACEMENT NOTES 1. LOOSEN SUBGRADE TO A MINIMUM DEPTH INDICATED IN PLANTING NOTES USING A CULTI-MULCHER OR SIMILAR EQUIPMENT, AND REMOVE STONES MEASURING OVER 1-1/2 INCHES IN ANY DIMENSION, STICKS, RUBBISH AND OTHER EXTRANEOUS MATTER. AREAS ADJACENT TO WALKS AND PAVEMENT SHALL BE FREE OF EXCESS STONE AND PAVING MATERIALS SO AS TO PROVIDE AN UNINTERRUPTED CROSS SECTION OF SOIL. INTERNAL PARKING ISLANDS SHALL BE LOOSENED TO A DEPTH OF 30". 2. THOROUGHLY BLEND PLANTING SOIL MIX FOR PLANTING BED AREAS. (1 PART EXISTING SOIL, 1 PART TOPSOIL, 1 PART ORGANIC SOIL AMENDMENT, 2.9 POUNDS PER CUBIC YARD OF 4-4-4 ANALYSIS SLOW-RELEASE FERTILIZER) 3. TREE AND SHRUB HOLES SHALL BE FILLED WITH A PREPARED PLANTING MIXTURE OF 1 PART TOPSOIL, 2 PARTS PLANTING SOIL MIX. 4. SPREAD SOIL AND SOIL AMENDMENTS TO DEPTH INDICATED ON DRAWINGS, BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. (FINISH GRADE OF PLANTING BEDS SHALL BE 3" BELOW ALL ADJACENT SURFACES. FINISH GRADE OF TURF SEEDING AREAS SHALL BE 1" BELOW ALL ADJACENT HARD SURFACES, WALKS, AND CURBS.) 5. PLACE APPROXIMATELY 1/2 OF TOTAL AMOUNT OF SOIL REQUIRED. WORK INTO TOP OF LOOSENED SUBGRADE TO CREATE A TRANSITION LAYER, THEN PLACE REMAINDER OF THE SOIL. SOIL TRANSITION LAYER SHALL BE TILLED TO A MINIMUM DEPTH OF 6" BELOW THE DEPTH OF NEWLY PLACED SOIL. PARKING LOT ISLANDS SHALL BE CROWNED TO A HEIGHT OF 6" TO PROVIDE PROPER DRAINAGE UNLESS OTHERWISE NOTED. 6. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 7. FINISH GRADING: GRADE SOIL TO A SMOOTH, UNIFORM SURFACE PLANE WITH A LOOSE, UNIFORMLY FINE TEXTURE. 8. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. 9. RESTORE PLANTING BEDS IF ERODED OR OTHERWISE DISTURBED AFTER FINISH GRADING AND BEFORE PLANTING. 1. THE LAYOUT OF ALL PLANTING BEDS AND INDIVIDUAL TREES AND SHRUBS SHALL BE STAKED BY THE CONTRACTOR IN ADVANCE OF INSTALLATION. FLAGGING, STAKES, OR PAINT MAY BE USED TO DELINEATE LOCATIONS AS SCALED FROM THE PLANS. AN APPROVED REPRESENTATIVE WILL REVIEW THESE LOCATIONS WITH THE CONTRACTOR AND MAKE MINOR ADJUSTMENTS AS NECESSARY. BED LAYOUT SHALL ALSO INCLUDE PERENNIAL GROUPINGS BY SPECIES. 2. THE CONTRACTOR IS RESPONSIBLE FOR INDEPENDENTLY DETERMINING THE PLANT MATERIAL QUANTITIES REQUIRED BY THE LANDSCAPE PLANS. REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT. 3. NO PLANT MATERIAL OR PLANT SIZE SUBSTITUTIONS WILL BE ACCEPTED WITHOUT APPROVAL BY THE LANDSCAPE ARCHITECT. ANY CHANGES SHALL BE SUBMITTED TO THE LANDSCAPE ARCHITECT IN WRITING PRIOR TO INSTALLATION. 4. ALL BNB STOCK SHALL BE NURSERY GROWN IN A CLAY LOAM SOIL FOR A MINIMUM OF THREE GROWING SEASONS WITHIN 200 MILES OF PROJECT LOCATION, IN A ZONE COMPATIBLE WITH USDA HARDINESS ZONE 5A. SEED SHALL BE PROVIDED FROM A NURSERY (WITHIN 200 MILES) WITH A SIMILAR PLANT HARDINESS ZONE AS PROJECT LOCATION. EXISTING SOIL SHALL BE AMENDED PER SOIL ANALYSIS REPORT TO ENSURE A PROPER GROWING MEDIUM IS ACHIEVED. 5. ALL PLANT MATERIAL SHALL COMPLY WITH STANDARDS DESCRIBED IN AMERICAN STANDARD OF NURSERY STOCK - Z60.1 ANSI. LANDSCAPE ARCHITECT OR OWNERS AUTHORIZED REPRESENTATIVE RESERVES THE RIGHT TO INSPECT AND POTENTIALLY REJECT ANY PLANT MATERIAL DEEMED TO NOT MEET THE REQUIRED STANDARDS. 6. ALL STOCK SHALL BE FREE OF DISEASES AND HARMFUL INSECTS, DAMAGE, DISORDERS AND DEFORMITIES. 7. TREES SHALL HAVE SINGLE, STRAIGHT TRUNKS AND WELL BALANCED BRANCH SYSTEMS. MUTLI-STEM TREES SHALL HAVE 3-4 STRAIGHT TRUNKS AND WELL BALANCED BRANCH SYSTEMS. HEIGHT-TO-CALIPER RATIOS SHALL BE CONSISTENT WITH THE LATEST EDITION OF ANSI Z60.1. 8. ROOT SYSTEMS SHALL BE LARGE ENOUGH TO ALLOW FOR FULL RECOVERY OF THE TREE, AND SHALL CONFORM TO STANDARDS AS THEY APPEAR IN THE MOST CURRENT REVISION OF THE AMERICAN ASSOCIATION OF NURSERYMEN'S AMERICAN STANDARD OF NURSERY STOCK ANSI Z60.1. 9. BNB TREES SHALL BE DUG WITH A BALL OF SOIL, NOT SOFT BALLED OR POTTED AND SHALL BE FIRM IN THEIR ROOTBALL. ROOT BALL SHALL BE WRAPPED (WITH BIODEGRADABLE MATERIAL). THE TREE ROOT FLARE, OR COLLAR, SHALL BE AT OR WITHIN THE TOP THREE INCHES OF GRADE. 10. ALL SPRING TREES MUST BE FRESHLY DUG IN THE MOST RECENT SPRING. 11. ALL AUTUMN TREES MUST BE FRESHLY DUG IN THE MOST RECENT AUTUMN. 12. TREES SHALL BE ALIVE, HEALTHY AND APPROPRIATELY MOIST, AT TIME OF DELIVERY. TREES SHALL BE SUBJECT TO INSPECTION FOR CONFORMITY TO SPECIFICATION REQUIREMENTS AND APPROVAL BY THE LANDSCAPE ARCHITECT OR OWNERS REPRESENTATIVE. THE LANDSCAPE ARCHITECT OR OWNERS REPRESENTATIVE RESERVES THE RIGHT TO REJECT ANY TREES THAT DO NOT MEET THE SPECIFICATIONS OR THAT HAVE BEEN DAMAGED DURING SHIPMENT. THE LANDSCAPE INSTALLER MUST RECEIVE APPROVAL FROM LANDSCAPE ARCHITECT FOR ANY SUBSTITUTIONS OR ALTERATIONS. 13. ALL PLANT MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH PLANTING DETAILS. 14. ALL PLANTING BEDS SHALL HAVE A MINIMUM 10" DEPTH OF PREPARED SOIL. WITH APPROVAL, EXISTING SOIL MAY BE UTILIZED PROVIDED THE PROPER SOIL AMENDMENTS ARE TILLED THOROUGHLY INTO THE TOP 10" OF SOIL. REFER TO SOIL PLACEMENT NOTES. 15. WHILE PLANTING TREES AND SHRUBS, BACKFILL 2 3 OF PLANTING HOLE AND WATER TREE THOROUGHLY BEFORE INSTALLING THE REMAINDER OF SOIL MIXTURE. AFTER ALL SOIL HAS BEEN PLACED INTO THE PLANTING HOLE WATER THOROUGHLY AGAIN. 16. THE CONTRACTOR MUST LABEL ALL TREES WITH THE COMMON AND BOTANICAL NAMES PRIOR TO FINAL INSPECTION. 17. OAK TREES SHALL BE TREATED FOR TWO-LINE CHESTNUT BORER BOTH AT THE TIME OF INSTALLATION AND DURING THE SECOND GROWING SEASON. 18. ALL PLANTING BEDS SHALL BE MULCHED WITH 3" DEEP SHREDDED HARDWOOD MULCH, AND ALL TREES PLANTED IN TURF AREAS SHALL RECEIVE A 3" DEEP SHREDDED HARDWOOD MULCHED RING AS SHOWN IN PLANTING DETAILS. 19. ALL PLANTING BEDS AND TREE RINGS SHALL HAVE A 4" DEEP TRENCHED BED EDGE CREATED BY EITHER A FLAT LANDSCAPE SPADE OR MECHANICAL EDGER. BED EDGES ARE TO BE CUT CLEAN AND SMOOTH AS SHOWN ON LANDSCAPE PLANS WITH A CLEAN DEFINITION BETWEEN TURF AND PLANTING AREAS. 20. ALL TURF SEED AREAS SHALL RECEIVE A MINIMUM OF 6" DEPTH OF TOPSOIL. WITH APPROVAL, EXISTING SOIL MAY BE UTILIZED PROVIDED THE PROPER SOIL AMENDMENTS ARE TILLED THOROUGHLY INTO THE TOP 6" OF SOIL AS INDICATED IN THE SOIL PLACEMENT NOTES. REQUIRED AMENDMENTS SHALL BE DETERMINED BASED ON A SOIL ANALYSIS TO BE PERFORMED. ALL TOPSOIL AMENDMENT SHALL BE AGED WEED FREE MANURE OR CLASS 1 ORGANIC MATTER. 21. FOR LAWN SEEDING, APPLY A STARTER FERTILIZER AND SEED UNIFORMLY AT THE RATE RECOMMENDED BY MANUFACTURER, AND PROVIDE A MULCH COVERING THAT IS SUITABLE TO PROMOTE SEED GERMINATION AND TURF ESTABLISHMENT. CONTRACTOR TO PROVIDE FERTILIZER, SEED, AND MULCH SPECIFICATIONS TO THE LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. EROSION CONTROL MEASURES ARE TO BE INSTALLED IN THOSE AREAS REQUIRING STABILIZATION ( SWALES, SLOPES EXCEEDING 1:3, AND THOSE LOCATIONS INDICATED IN CIVIL DRAWINGS). 22. THE CONTRACTOR TO ENSURE A SMOOTH, UNIFORM QUALITY TURF IS ACHIEVED WITH NO BARE SPOTS LARGER THAN 6" X 6". ANY BARE SPOTS LARGER THAN 6" X6" AT THE END OF ESTABLISHMENT PERIOD SHALL BE RESEEDED AT THE CONTRACTORS EXPENSE TO OBTAIN A DENSE, UNIFORM LAWN. 23. ALL FINISH GRADING AND LAWN AREAS TO BE INSTALLED BY LANDSCAPE CONTRACTOR. 24. ALL DISTURBED AREAS WITHIN THE PROJECT SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. 25. ALL DISTURBED AREAS OUTSIDE THE LIMITS OF WORK SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST TO THE OWNER. 26. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, INCLUDING ANY IRRIGATION LINES, PRIOR TO DIGGING. CONSULT DIGGERS HOTLINE. 27. TREES SHALL BE INSTALLED NO CLOSER THAN: -10 FEET FROM ANY FIRE HYDRANT - 7 FEET FROM STORM SEWER, SANITARY SEWER LATERALS, DRIVEWAYS, AND WATER SERVICE 28. THE CONTRACTOR SHALL ENSURE THAT SOIL CONDITIONS AND COMPACTION ARE ADEQUATE TO ALLOW FOR PROPER DRAINAGE AROUND THE CONSTRUCTION SITE. UNDESIRABLE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING OF WORK. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE PROPER SURFACE AND SUBSURFACE DRAINAGE IN ALL AREAS 29. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, FEES, AND LICENSES NECESSARY FOR THE INSTALLATION OF THIS PLAN. 30. THE CONTRACTOR IS TO REVIEW ALL SITE ENGINEERING DOCUMENTS PRIOR TO INSTALLATION. ANY CONFLICTS MUST BE REPORTED TO THE LANDSCAPE ARCHITECT. THESE LANDSCAPE DRAWINGS ARE FOR THE INSTALLATION OF PLANT MATERIALS ONLY UNLESS OTHERWISE STATED. 31. THE CONTRACTOR SHALL PROVIDE WATERING AND MAINTENANCE SERVICES FOR A PERIOD OF 60 DAYS TO ENSURE VEGETATIVE ESTABLISHMENT. UPON COMPLETION OF THE PROJECT, CONTRACTOR SHALL SUPPLY THE OWNER IN WRITING WITH ONGOING WATERING AND MAINTENANCE INSTRUCTIONS. 32. PLANT MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM TIME OF OWNER ACCEPTANCE. ONLY ONE REPLACEMENT PER PLANT WILL BE REQUIRED DURING THE WARRANTY PERIOD EXCEPT IN THE EVENT OF FAILURE TO COMPLY WITH THE SPECIFIED REQUIREMENTS. 33. THE CONTRACTOR IS RESPONSIBLE TO CONDUCT A FINAL WALK THROUGH WITH THE LANDSCAPE ARCHITECT AND OR OWNERS REPRESENTATIVE TO ANSWER QUESTIONS, PROVIDE INSTRUCTIONS, AND ENSURE THAT PROJECT REQUIREMENTS HAVE BEEN MET. GENERAL PLANTING NOTES DESIGNED: REVIEWED:DRAFTED: © COPYRIGHT 2026 THESE PLANS AND DESIGNS ARE COPYRIGHT PROTECTED AND MAY NOT BE USED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF PINNACLE ENGINEERING GROUP, LLC REVISIONS SHEET PEG JOB No. PEG PM PLAN DATE SCALE PINNACLE ENGINEERING GROUP PINNACLE ENGINEERING GROUP www.pinnacle-engr.com WISCONSIN OFFICE: 20725 WATERTOWN ROAD, SUITE 100 BROOKFIELD, WI 53186 (262) 754-8888 ENGINEERING I NATURAL RESOURCES I SURVEYING PLAN I DESIGN I DELIVER CHICAGO I MILWAUKEE : NATIONWIDE w w w . p i n n a c l e - e n g r . c o m Z:\PROJECTS\2025\6920.00-WI\CAD\SHEETS\6920.00-WI LANDSCAPE PLAN.DWG OF FRANKLIN, WI 6920.00 TGM 08/18/26 L-6 EAK SAT DJB LANDSCAPE GENERAL NOTES & DETAILS 1 CITY COMMENTS 11/09/26 L-6 VARIESLANDSCAPE GENERAL NOTES & DETAILS FRANKLIN SIX SIBS TREE WITH STRONG CENTRAL LEADER (DO NOT CUT LEADER) PRUNE ONLY TO REMOVE DAMAGED OR BROKEN BRANCHES. TREE STAKING IF REQUIRED (ONLY 1 OF 3 @ 120 DEG. SHOWN FOR CLARITY). STEEL STAKES & FLEXIBLE GUYING MATERIAL. FLAG GUYS FOR SAFETY TREE WRAP TO FIRST BRANCH (MAPLES AND OTHER THIN BARKED DECIDUOUS TREES). PLACE WRAP IN LATE FALL AND REMOVE EARLY SPRING. 4' X 4" A.M. LEONARD RIGID PLASTIC MESH TREE GUARD, BG48 TREE WATERING BAG. INSTALL SAME DAY TREE IS PLANTED. BAG SHALL BE FILLED ONCE PER WEEK THROUGH THE MAINTENANCE PERIOD. CROWN OF ROOT BALL 1" ABOVE FINISHED GRADE LEAVING TRUNK FLARE VISIBLE AT TOP OF ROOT BALL. 3" DEEP SHREDDED HARDWOOD MULCH IN 6'-0" DIAMETER RING. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK. NO MOUNDING. PROVIDE MULCH WEEDING ONCE PER MONTH THROUGH MAINTENANCE PERIOD. ROUGHEN EDGES OF PLANTING PIT. PLANTING MIXTURE BACKFILL TAMP PLANTING MIX AROUND BASE TO STABILIZE TREE. INSTALL (1) SLOW RELEASE FERTILIZER PACKET FOR EVERY CALIPER INCH OF TREE. INSTALL AGAINST ROOT BALL. REMOVE ALL TWINE, ROPE, WIRE, BURLAP AND PLASTIC WRAP FROM TOP HALF OF ROOT BALL. IF WIRE BASKET, CUT IN (4) PLACES AROUND THE ROOT BALL AND FOLD DOWN 8" INTO PLANTING PIT. ROOT BALL ON UNEXCAVATED OR COMPACTED PEDESTAL TO PREVENT SETTLING (1/2 - 2/3) OF TREE HEIGHT DEPTH OF ROOT BALL 6" ROOT BALL EXCAVATE TREE PIT TO BE AT LEAST 2 TIMES WIDER THAN ROOT BALL TREE PLANTING 1/4" = 1'-0"1 329343-01 COMPACTED TOPSOIL SAUCER, DO NOT EXCEED ANGLE OF REPOSE SET ROOT COLLAR FLUSH WITH SLOPE GRADE 3" DEEP SHREDDED HARDWOOD MULCH PLANTING MIXTURE ROOT BALL SEE PLANTING DETAIL 12" MIN. (TREES) 6" MIN. (SHRUB) EXISTING SLOPE TREE PLANTING ON SLOPE 3/8" = 1'-0"2 329343-02 IF NEEDED, PRUNE TO REMOVE DAMAGED, BROKEN, OR OVERLAPPING BRANCHES ONLY AFTER PLANTING. PRUNING IS SUBJECT TO TIME OF YEAR FOR EACH INDIVIDUAL SPECIES. TREE STAKING (ONLY 1 OF 3 @ 120 DEG. SHOWN FOR CLARITY). 3" DIAMETER CEDAR WOOD STAKES & FLEXIBLE GUYING MATERIAL. FLAG GUYS FOR SAFETY. STAKES SHALL NOT TOUCH THE SIDES OF ROOT BALL WHEN INSTALLED. CROWN OF ROOT BALL 2" ABOVE FINISHED GRADE LEAVING TRUNK FLARE VISIBLE AT TOP OF ROOT BALL. 3" DEEP SHREDDED HARDWOOD MULCH IN 6'-0" DIAMETER RING. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK. NO MOUNDING. PROVIDE MULCH WEEDING ONCE PER MONTH THROUGH MAINTENANCE PERIOD. ROUGHEN EDGES OF PLANTING PIT. PLANTING MIXTURE BACKFILL. TAMP PLANTING MIX AROUND BASE TO STABILIZE TREE. INSTALL (1) SLOW RELEASE FERTILIZER PACKET FOR EVERY 24" OF TREE HEIGHT. INSTALL PACKET AGAINST ROOT BALL. REMOVE ALL TWINE, ROPE, WIRE, BURLAP AND PLASTIC WRAP FROM TOP HALF OF ROOT BALL. IF WIRE BASKET, CUT IN (4) PLACES AROUND THE ROOT BALL AND FOLD DOWN 8" INTO PLANTING PIT. ROOT BALL ON UNEXCAVATED OR COMPACTED PEDESTAL TO PREVENT SETTLING (1/2) OF TREE HEIGHT DEPTH OF ROOT BALL 6" ROOT BALL EXCAVATE TREE PIT TO BE AT LEAST 2 TIMES WIDER THAN ROOT BALL EVERGREEN TREE PLANTING 1/4" = 1'-0" 329343-03 3 SCARIFY 4" AND RECOMPACT SUBGRADE SHRUB PLANTING PRUNE ONLY TO REMOVE DEAD OR BROKEN BRANCHES 3" MULCH TOPSOIL REMOVE ALL TWINE, ROPE, WIRE, BURLAP AND PLASTIC WRAP FROM TOP HALF OF ROOT BALL HAND LOOSEN AND PULL ROOTS OUT OF CONTAINER MATERIAL TO PREVENT PLANT FROM BECOMING ROOT BOUND 10" MIN. PER PLANT SPACING BALLED AND BURLAPPED BARE ROOT OR CONTAINER BOTTOM OF ROOT FLARE FLUSH WITH FINISHED GRADE BAREROOT PLANTING NOTES: 1. SOAK ROOTS IN WATER FOR AT LEAST ONE HOUR BUT NOT MORE THAN 24 HOURS PRIOR TO PLANTING. 2. SCARIFY SIDES AND BOTTOMS OF HOLE. 3. PROCEED WITH CORRECTIVE PRUNING OF THE TOP AND BOTTOM ROOTS. 4. TRANSFER PLANT DIRECTLY FROM WATER TO HOLE. SET PLANT SO THE ROOT FLARE IS APPROXIMATELY AT THE FINISHED SOIL ELEVATION. SPREAD ROOTS OUT EVENLY. PLUMB AND IMMEDIATELY BACKFILL WITH PLANTING SOIL MIX. 5. WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTS AND FILL VOIDS. 6. BACKFILL VOIDS AND WATER SECOND TIME. 7. PLACE MULCH WITHIN 48 HOURS OF THE SECOND WATERING UNLESS SOIL MOISTURE IS EXCESSIVE. SHRUB PLANTING 1/2" = 1'-0" 329333-02 4 PERENNIAL PLANTING 3" MULCH FINISHED GRADE TOP OF MULCH HAND LOOSEN AND PULL ROOTS OUT OF CONTAINER MATERIAL TO PREVENT PLANT FROM BECOMING ROOT BOUND PLANTING MIX SUBGRADE PER PLANT SPACING 10" PERENNIAL PLANTING 1" = 1'-0"5 3293-01 SHRUB OR PERENNIAL (*) (*) (*) (*) = SPECIFIED PLANT SPACING PER PLANTING LIST PLANT SPACING 3/4" = 1'-0"6 3293-02 TURF FINISHED GRADE STRAIGHT, CLEAN CUT THROUGH GRASS MULCH BED 45° ANGLE CUT BACK TO FINISHED GRADE OF MULCH BED 4" TRENCHED BED EDGE 3/4" = 1'-0"7 3293-03 Riverwoods, IL 60015 2610 Lake Cook Road Ph.: (847) 940-0300 Suite 280 www.pidarchitects.com © 2026 Partners in Design Architects, Inc. 2 A4.2 1 A4.2 3 A4.2 4 A4.2 A B C D E F 1 2 3 4 5 6 7 8 9 10 11 500'-0" OVERALL 255'-0" OVERALL 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 14'-0" 14'-0" 6'-10" 36 PANELS @ 12'-0" = 432'-0" 6'-10" 14'-0" 14'-0" 10" 10" 1'-0" 1'-6" 3'-4" 2'-0" 12'-0" 13'-6" 9'-0" 3'-0" 9'-0" 3'-0" 9'-0" 15'-0" 9'-0" 3'-0" 9'-0" 5'-10" 3'-4" 40'-4" 12'-0" 3'-10" 3'-4" 6'-4" 9'-0" 3'-0" 9'-0" 3'-0" 9'-0" 27'-0" 9'-0" 3'-0" 9'-0" 3'-0" 9'-0" 6'-4" 3'-4" 3'-10" 12'-0" 40'-4" 3'-4" 5'-10" 9'-0" 3'-0" 9'-0" 15'-0" 9'-0" 3'-0" 9'-0" 3'-0" 9'-0" 13'-6" 12'-0" 2'-0" 3'-4" 1'-6" 1'-0" ROOF DRAIN, RUN DRAIN PIPE BELOW DECK AND RUN DOWN INSIDE FACE OF WALL AND CONNECT TO UNDERSLAB STORM PIPE - SEE CIVIL DRAWINGS, COORDIANTE WITH TRENCH FOOTINGS WAREHOUSE 100 ELECTRICAL 101 FIRE PROTECTION 102 10"60'-0"48'-9"48'-9"48'-9"48'-9" 3'-10" 3 PANELS @ 14'-0" = 42'-0"14'-0"11 PANELS @ 14'-0" = 154'-0"12'-0"34'-8" 3'-0" 1'-0" 1'-0" 33'-4" 3'-4" 122'-8" 3'-4" 5'-4"1'-0" 6'-4" 5'-8" 20'-8" 1'-0" 4'-8" 3'-0" 34'-8" 13'-2" 7 PANELS @ 14'-0" = 98'-0" 14'-0" 3 PANELS @ 14'-0" = 42'-0" 14'-0" 5 PANELS @ 14'-0" = 70'-0" 14'-0" 3 PANELS @ 14'-0" = 42'-0" 14'-0" 7 PANELS @ 14'-0" = 98'-0" 13'-2" 34'-8" 3'-0" 1'-0" 20'-8" 5'-8" 6'-4" 1'-0" 47'-4" 3'-4" 61'-4" 3'-0" 8'-0" 3'-0" 14'-0" 3'-0" 8'-0" 3'-0" 33'-4" 3'-4" 61'-4" 3'-0" 8'-0" 3'-0" 14'-0" 3'-0" 8'-0" 3'-0" 61'-4" 3'-4" 47'-4" 1'-0" 6'-4" 5'-8" 20'-8" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 4'-8" 4'-8" 3'-0" 34'-8" 12'-0" 11 PANELS @ 14'-0" = 154'-0" 14'-0" 3 PANELS @ 14'-0" = 42'-0" 1'-0" 1'-0" 1'-0" 20'-8" 5'-8" 6'-4" 1'-0" 33'-4" 3'-4" 122'-8" 3'-4" 5'-4" 19'-4" 3'-4" 10'-8" 3'-4" 5'-4" 67'-10" 8'-0" 6'-0" 8'-0" 34'-0" 8'-0" 6'-0" 8'-0" CLERESTORY WINDOWS 76'-0" 8'-0" 6'-0" 8'-0" 20'-0" 8'-0" 6'-0" 8'-0" 76'-0" 8'-0" 6'-0" 8'-0" 34'-0" 8'-0" 6'-0" 8'-0" 67'-10" 48'-10" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" CLERESTORY WINDOWS 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 28'-0" 8'-0" 4'-0" 8'-0" 87'-0"8'-0" 6'-0" 8'-0" CLERESTORY WINDOWS 34'-0"8'-0" 6'-0" 8'-0"94'-8" 87'-0"8'-0" 6'-0" 8'-0" CLERESTORY WINDOWS 34'-0"8'-0" 6'-0" 8'-0"94'-8" 48'-10" A3.2 1 A3.2 2 Riverwoods, IL 60015 2610 Lake Cook Road PROJECT NO.: Ph.: (847)940-0300 CHECKED BY:DRAWN BY: DATE: SHEET NO.: REVISIONS: Suite 280 FRANKLIN CORPORATE PARK PHASE 2 10651 S. Hickory Street, Franklin, WI BUILDING A FLOOR PLAN A3.1 1039.25.101 TLB WHB 07.17.26 A3.1 3/64" = 1'-0" 1 FLOOR PLAN © 2026 Partners in Design Architects, Inc. FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" A4.4 3 A B C D E F PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PREFINISHED METAL COPING - TYP. PAINTED HOLLOW METAL DOOR AND FRAME - TYP. PRECAST REVEALS - TYP. PAINTED INSULATED PRECAST CONCRETE WALL PANELS - TYP. PREFINISHED METAL PANEL CANOPY PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PROVIDE KNOCK-OUT IN PRECAST PANEL FOR FUTURE OPENING - TYP. FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" 1 2 3 4 5 6 7 8 9 10 11 A4.4 1 PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PREFINISHED METAL PANEL CANOPY PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PREFINISHED METAL COPING - TYP. PRECAST REVEALS - TYP. PAINTED INSULATED PRECAST CONCRETE WALL PANELS - TYP. A4.4 2 PREFINISHED METAL PANEL CANOPY PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PROVIDE KNOCK-OUT IN PRECAST PANEL FOR FUTURE OPENING - TYP. FORMLINER - TYP. FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" 1234567891011 PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. INSULATED SECTIONAL OVERHEAD DOOR W/ VISION LITE, COMPRESSIBLE DOCK SEALS AND BUMPERS - TYP. GALVANIZED STEEL STAIR - TYP. PREFINISHED METAL COPING - TYP. PAINTED HOLLOW METAL DOOR AND FRAME - TYP. PRECAST REVEALS - TYP. PAINTED INSULATED PRECAST CONCRETE WALL PANELS - TYP. 12'-0" x 14'-0" INSULATED SECTIONAL OVERHEAD DOOR WITH VISION LITE - TYP. FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" ABCDEF PREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PREFINISHED METAL COPING - TYP. PAINTED HOLLOW METAL DOOR AND FRAME - TYP. PRECAST REVEALS - TYP. PAINTED INSULATED PRECAST CONCRETE WALL PANELS - TYP. PREFINISHED METAL PANEL CANOPYPREFINISHED ALUMINUM FRAMING AND INSULATED GLAZING - TYP. PROVIDE KNOCK-OUT IN PRECAST PANEL FOR FUTURE OPENING - TYP. FORMLINER - TYP. FIELD COLOR 1: SHERWIN WILLIAMS T.B.D. ACCENT AND METAL COPING COLOR 2: SHERWIN WILLIAMS T.B.D. ACCENT COLOR 3: SHERWIN WILLIAMS T.B.D. COLOR LEGEND: *COLORS ON ELEVATIONS ARE REPRESENTATIVE OF LIGHTS AND DARKS ONLY. Riverwoods, IL 60015 2610 Lake Cook Road PROJECT NO.: Ph.: (847)940-0300 CHECKED BY:DRAWN BY: DATE: SHEET NO.: REVISIONS: Suite 280 FRANKLIN CORPORATE PARK PHASE 2 10651 S. Hickory Street, Franklin, WI TYPICAL BUILDING ELEVATIONS A4.2 1039.25.101 TLB WHB 07.17.26 A4.2 1" = 20'-0" 2 WEST ELEVATION A4.2 1" = 20'-0" 1 SOUTH ELEVATION A4.2 1" = 20'-0" 3 NORTH ELEVATION A4.2 1" = 20'-0" 4 EAST ELEVATION © 2026 Partners in Design Architects, Inc. FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" 1 2 FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" 5 FIN. FLOOR 100' - 0" T/ PANEL (A) 136' - 0" T/ PANEL (B) 138' - 6" E F Riverwoods, IL 60015 2610 Lake Cook Road PROJECT NO.: Ph.: (847)940-0300 CHECKED BY:DRAWN BY: DATE: SHEET NO.: REVISIONS: Suite 280 FRANKLIN CORPORATE PARK PHASE 2 10651 S. Hickory Street, Franklin, WI TYPICAL BUILDING ENLARGED ELEVATIONS A4.4 1039.25.101 TLB WHB 07.17.26 A4.4 1" = 10'-0" 1 ENLARGED ELEVATION A4.4 1" = 10'-0" 2 ENLARGED ELEVATION A4.4 1" = 10'-0" 3 ENLARGED ELEVATION A4.4 4 SOUTHWEST CORNER A4.4 5 NORTHEAST CORNER © 2026 Partners in Design Architects, Inc. A B C D E F 1 2 3 4 5 6 7 8 9 10 11 R.D. R.D. 0" R.D.0" R.D. DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN 25" 0" 0" 0" 0" 0" 0" 0" 0" -15" 6" 0"6"12.5" 12.5" 12.5" DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN 12" 12" DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/8" PER FOOT - MIN DN 1/4" PER FOOT - MIN 0" R.D. -15" R.D. -15"0" 0" 0" 0"0" 0" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 25" 25" 25" 25" 25" 25" 6" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 12.5" 6" 6" 12.5" R.D. 0" 12.5" R.D. 0" 6" DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN DN 1/4" PER FOOT - MIN Riverwoods, IL 60015 2610 Lake Cook Road PROJECT NO.: Ph.: (847)940-0300 CHECKED BY:DRAWN BY: DATE: SHEET NO.: REVISIONS: Suite 280 FRANKLIN CORPORATE PARK PHASE 2 10651 S. Hickory Street, Franklin, WI BUILDING A ROOF PLAN A9.1 1039.25.101 TLB WHB 07.17.26 A9.1 3/64" = 1'-0" 1 ROOF PLAN © 2026 Partners in Design Architects, Inc. Luminaire Schedule Qty Label Arrangement LLF MFG Description Lum. Watts Total Watts Lum. Lumens 8 OA4H Single 0.950 LITHONIA RSX1 LED P3 xxK R4 MVOLT SPA HS + 20' POLE + 3' BASE 109 872 9336 20 OD1L Single 0.950 LITHONIA LDN4 ALO2 SWW1 LO4AR LSS MVOLT (1000LM) 13 260 1355 4 OW1 Single 0.950 LITHONIA WDGE2 LED P3 xxK 80CRI T3M MVOLT (mounting) 32 128 3216 14 OW2 Single 0.950 LITHONIA WDGE3 LED P3 xxK 80CRI RFT MVOLT (mounting) 71 994 10145 14 OW3 Single 0.950 LITHONIA WDGE3 LED P4 xxK 80CRI RFT MVOLT (mounting) 88 1232 12277 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Typical Exterior at Grade Illuminance Fc 0.08 0.50 0.00 N.A. N.A. BLDG A Loading Docks Illuminance Fc 1.49 2.6 0.7 2.13 3.71 BLDG A Parking Illuminance Fc 1.04 2.7 0.3 3.47 9.00 BLDG B Loading Docks Illuminance Fc 1.55 2.8 0.9 1.72 3.11 BLDG B Parking Illuminance Fc 0.91 2.8 0.3 3.03 9.33 Trailer Stalls Illuminance Fc 1.44 4.1 0.3 4.80 13.67 OA4H MH: 23 OA4H MH: 30 OA4H MH: 30 OA4H MH: 23 OA4H MH: 23 OA4H MH: 23 OA4H MH: 23 OA4H MH: 23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.02 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.02 0.02 0.03 0.03 0.04 0.03 0.03 0.03 0.03 0.03 0.03 0.04 0.04 0.05 0.05 0.05 0.05 0.04 0.04 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.06 0.06 0.06 0.06 0.06 0.05 0.05 0.04 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.05 0.06 0.06 0.06 0.06 0.06 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.04 0.05 0.05 0.05 0.05 0.05 0.04 0.04 0.03 0.03 0.03 0.03 0.03 0.04 0.04 0.03 0.03 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.03 0.03 0.04 0.05 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.13 0.13 0.13 0.11 0.10 0.09 0.08 0.07 0.06 0.06 0.06 0.06 0.07 0.07 0.08 0.09 0.11 0.12 0.13 0.13 0.12 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.08 0.08 0.08 0.08 0.08 0.08 0.07 0.06 0.05 0.04 0.03 0.03 0.03 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.05 0.05 0.05 0.07 0.09 0.11 0.14 0.17 0.18 0.18 0.18 0.18 0.18 0.19 0.17 0.16 0.15 0.15 0.16 0.18 0.19 0.18 0.18 0.18 0.18 0.17 0.16 0.14 0.24 0.25 0.24 0.20 0.17 0.14 0.12 0.10 0.09 0.09 0.08 0.09 0.10 0.11 0.13 0.15 0.19 0.22 0.25 0.25 0.23 0.15 0.17 0.17 0.18 0.18 0.18 0.19 0.18 0.17 0.15 0.15 0.15 0.16 0.18 0.19 0.18 0.18 0.18 0.18 0.18 0.16 0.13 0.10 0.08 0.06 0.05 0.05 0.06 0.04 0.03 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.08 0.08 0.08 0.10 0.13 0.16 0.21 0.28 0.33 0.33 0.33 0.34 0.34 0.32 0.26 0.23 0.22 0.22 0.23 0.27 0.32 0.34 0.34 0.33 0.33 0.32 0.27 0.20 0.43 0.44 0.40 0.33 0.27 0.22 0.18 0.15 0.13 0.11 0.11 0.12 0.14 0.16 0.19 0.24 0.30 0.37 0.43 0.44 0.39 0.23 0.29 0.33 0.33 0.33 0.34 0.34 0.30 0.25 0.22 0.21 0.22 0.24 0.28 0.33 0.34 0.33 0.33 0.33 0.32 0.25 0.19 0.15 0.12 0.10 0.09 0.09 0.09 0.07 0.06 0.04 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.06 0.10 0.16 0.24 0.30 0.30 0.22 0.17 0.16 0.18 0.23 0.28 0.36 0.43 0.48 0.48 0.49 0.45 0.39 0.33 0.29 0.28 0.28 0.30 0.33 0.40 0.46 0.49 0.49 0.47 0.41 0.33 0.26 0.70 0.71 0.61 0.49 0.38 0.30 0.24 0.20 0.16 0.14 0.13 0.15 0.18 0.22 0.27 0.34 0.43 0.55 0.66 0.72 0.64 0.29 0.37 0.44 0.48 0.48 0.48 0.43 0.37 0.31 0.29 0.28 0.28 0.30 0.35 0.41 0.47 0.49 0.49 0.47 0.40 0.33 0.26 0.22 0.18 0.18 0.22 0.29 0.32 0.27 0.18 0.11 0.07 0.04 0.03 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.05 0.10 0.18 0.31 0.52 0.69 0.65 0.45 0.28 0.22 0.22 0.27 0.34 0.42 0.55 0.72 0.70 0.71 0.65 0.44 0.40 0.33 0.31 0.31 0.34 0.41 0.46 0.68 0.71 0.70 0.72 0.52 0.40 0.32 0.99 0.98 0.82 0.65 0.50 0.39 0.30 0.24 0.19 0.16 0.16 0.17 0.21 0.27 0.34 0.44 0.57 0.73 0.91 1.02 0.27 0.36 0.43 0.64 0.71 0.70 0.72 0.56 0.43 0.37 0.32 0.30 0.31 0.35 0.42 0.50 0.72 0.71 0.71 0.71 0.47 0.40 0.31 0.26 0.24 0.28 0.41 0.63 0.72 0.58 0.35 0.21 0.12 0.06 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.06 0.09 0.15 0.24 0.36 0.55 0.83 1.11 1.08 0.81 0.48 0.36 0.31 0.32 0.39 0.44 0.63 0.70 0.89 0.77 0.63 0.41 0.38 0.30 0.25 0.26 0.30 0.40 0.41 0.63 0.81 0.88 0.66 0.54 0.40 0.30 1.31 1.29 1.05 0.81 0.61 0.47 0.36 0.28 0.22 0.18 0.18 0.20 0.24 0.31 0.41 0.54 0.70 0.92 1.19 1.35 0.25 0.36 0.39 0.62 0.77 0.89 0.70 0.61 0.42 0.35 0.28 0.25 0.26 0.32 0.42 0.46 0.64 0.86 0.85 0.65 0.46 0.45 0.37 0.34 0.37 0.45 0.73 1.06 1.16 0.93 0.62 0.40 0.26 0.17 0.11 0.07 0.04 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.02 0.04 0.07 0.12 0.21 0.36 0.60 0.90 1.21 1.68 2.29 2.69 2.65 2.26 1.57 1.58 1.29 0.93 0.70 0.54 0.40 0.30 0.24 0.20 0.20 0.22 0.27 0.35 0.46 0.61 0.80 1.10 1.48 1.68 2.14 2.65 2.78 2.42 1.81 1.30 0.98 0.67 0.41 0.24 0.14 0.08 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.03 0.05 0.09 0.16 0.29 0.50 0.78 1.07 1.30 1.64 2.12 2.49 2.46 2.19 2.13 2.06 1.53 1.11 0.80 0.60 0.44 0.33 0.26 0.22 0.21 0.23 0.29 0.38 0.51 0.70 0.93 1.34 1.85 2.31 2.06 2.47 2.56 2.25 1.75 1.37 1.13 0.86 0.57 0.34 0.19 0.10 0.06 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.09 0.16 0.30 0.50 0.75 0.99 1.16 1.39 1.71 1.93 1.95 5.43 2.48 2.33 1.71 1.27 0.89 0.66 0.48 0.36 0.28 0.24 0.23 0.25 0.31 0.41 0.56 0.76 1.05 1.51 2.04 2.68 6.62 2.76 1.98 1.79 1.47 1.21 1.04 0.81 0.56 0.34 0.19 0.11 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.08 0.14 0.27 0.44 0.65 0.82 0.95 1.14 1.34 1.50 1.57 11.63 2.22 2.21 1.70 1.25 0.92 0.70 0.53 0.40 0.31 0.27 0.26 0.29 0.35 0.45 0.60 0.81 1.07 1.48 2.01 2.42 1.74 14.29 3.98 1.54 1.41 1.20 1.01 0.86 0.70 0.49 0.31 0.17 0.10 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.08 0.12 0.21 0.33 0.46 0.57 0.67 0.78 0.89 0.99 1.08 4.45 2.72 1.89 1.97 1.65 1.24 0.95 0.74 0.57 0.44 0.35 0.30 0.28 0.31 0.39 0.49 0.65 0.84 1.08 1.43 1.87 2.05 1.58 5.48 1.81 1.03 0.94 0.83 0.71 0.61 0.50 0.37 0.24 0.14 0.09 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.07 0.11 0.17 0.24 0.33 0.43 0.52 0.64 0.77 0.91 1.03 1.04 0.85 1.70 1.82 1.58 1.27 0.99 0.77 0.60 0.47 0.37 0.31 0.30 0.33 0.41 0.53 0.67 0.87 1.12 1.42 1.72 1.84 1.45 0.97 1.06 0.97 0.84 0.70 0.57 0.47 0.37 0.28 0.19 0.12 0.08 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.07 0.10 0.14 0.21 0.29 0.39 0.51 0.66 0.84 1.04 1.23 1.30 1.03 1.66 1.79 1.56 1.27 1.00 0.78 0.61 0.48 0.38 0.32 0.31 0.34 0.42 0.54 0.69 0.88 1.12 1.42 1.70 1.80 1.42 1.20 1.29 1.14 0.94 0.74 0.58 0.45 0.34 0.24 0.17 0.12 0.08 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.03 0.05 0.07 0.10 0.14 0.20 0.29 0.40 0.54 0.71 0.93 1.23 1.59 1.77 1.37 1.83 1.91 1.62 1.27 0.98 0.77 0.60 0.47 0.37 0.32 0.31 0.34 0.42 0.52 0.67 0.86 1.11 1.44 1.80 1.97 1.52 1.65 1.70 1.42 1.07 0.81 0.62 0.46 0.34 0.24 0.16 0.11 0.08 0.05 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.03 0.04 0.06 0.09 0.13 0.19 0.28 0.40 0.56 0.77 1.03 1.45 2.04 2.37 1.78 2.13 2.17 1.74 1.28 0.97 0.75 0.57 0.45 0.36 0.31 0.30 0.33 0.40 0.51 0.65 0.85 1.11 1.50 2.01 2.28 1.70 2.22 2.21 1.72 1.21 0.89 0.66 0.47 0.33 0.23 0.16 0.11 0.08 0.05 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.03 0.04 0.06 0.09 0.13 0.19 0.27 0.40 0.58 0.82 1.13 1.63 2.30 3.01 2.04 2.57 2.44 1.82 1.36 0.98 0.74 0.56 0.43 0.34 0.30 0.29 0.32 0.38 0.49 0.64 0.85 1.14 1.60 2.14 2.72 1.91 2.83 2.65 1.89 1.37 0.96 0.69 0.48 0.33 0.23 0.16 0.11 0.08 0.05 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.04 0.06 0.09 0.13 0.19 0.27 0.40 0.58 0.81 1.12 1.63 2.30 3.00 2.04 2.52 2.42 1.81 1.34 0.98 0.74 0.56 0.43 0.35 0.30 0.29 0.32 0.38 0.49 0.64 0.85 1.13 1.59 2.13 2.68 1.89 2.82 2.64 1.88 1.36 0.95 0.69 0.48 0.33 0.23 0.16 0.11 0.08 0.05 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.03 0.05 0.07 0.10 0.14 0.19 0.28 0.40 0.55 0.76 1.02 1.44 2.00 2.34 1.73 2.08 2.13 1.74 1.28 0.97 0.76 0.58 0.45 0.36 0.31 0.30 0.33 0.40 0.51 0.66 0.85 1.11 1.49 2.00 2.23 1.68 2.20 2.19 1.71 1.20 0.88 0.65 0.48 0.34 0.23 0.16 0.11 0.08 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 0.04 0.05 0.07 0.10 0.14 0.20 0.29 0.40 0.53 0.71 0.93 1.23 1.58 1.74 1.34 1.80 1.90 1.62 1.28 0.98 0.77 0.60 0.47 0.38 0.32 0.31 0.34 0.42 0.53 0.68 0.87 1.12 1.44 1.79 1.94 1.51 1.62 1.68 1.41 1.07 0.81 0.62 0.46 0.34 0.24 0.17 0.12 0.08 0.06 0.04 0.03 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.08 0.10 0.14 0.20 0.29 0.38 0.51 0.66 0.85 1.06 1.24 1.18 0.91 1.66 1.79 1.57 1.28 1.01 0.79 0.62 0.49 0.39 0.33 0.32 0.35 0.43 0.55 0.69 0.89 1.13 1.43 1.70 1.80 1.41 1.18 1.30 1.15 0.95 0.74 0.58 0.44 0.34 0.24 0.17 0.12 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.11 0.15 0.20 0.28 0.38 0.48 0.62 0.77 0.94 1.06 0.81 0.62 1.73 1.85 1.60 1.28 1.00 0.78 0.61 0.48 0.38 0.32 0.31 0.35 0.43 0.54 0.68 0.88 1.13 1.43 1.75 1.87 1.46 0.75 0.82 1.01 0.85 0.69 0.54 0.43 0.33 0.24 0.17 0.13 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.11 0.15 0.20 0.28 0.37 0.48 0.60 0.74 0.90 1.01 0.51 0.37 1.96 2.03 1.70 1.27 0.97 0.76 0.59 0.46 0.37 0.32 0.31 0.34 0.41 0.52 0.66 0.86 1.10 1.47 1.91 2.10 1.61 0.45 0.53 0.96 0.81 0.66 0.53 0.42 0.33 0.24 0.17 0.13 0.10 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.11 0.15 0.21 0.29 0.38 0.48 0.61 0.77 0.93 1.07 3.46 2.36 2.34 1.79 1.32 0.98 0.75 0.57 0.44 0.35 0.31 0.30 0.32 0.39 0.50 0.64 0.85 1.12 1.55 2.09 2.56 1.82 4.79 1.48 1.00 0.85 0.69 0.54 0.43 0.33 0.24 0.17 0.13 0.10 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.11 0.15 0.21 0.29 0.39 0.52 0.66 0.84 1.05 1.24 7.21 2.63 2.49 1.85 1.38 0.99 0.74 0.56 0.43 0.34 0.30 0.29 0.32 0.38 0.49 0.64 0.85 1.15 1.63 2.18 2.82 1.94 10.15 2.92 1.14 0.94 0.74 0.58 0.45 0.34 0.24 0.17 0.13 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.11 0.15 0.21 0.30 0.41 0.55 0.72 0.94 1.22 1.58 8.82 2.30 2.30 1.77 1.31 0.97 0.75 0.57 0.44 0.35 0.31 0.30 0.33 0.39 0.50 0.65 0.85 1.11 1.54 2.07 2.49 1.80 10.15 2.87 1.40 1.07 0.82 0.63 0.47 0.35 0.25 0.17 0.13 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.08 0.11 0.15 0.21 0.30 0.43 0.59 0.80 1.06 1.47 2.04 6.60 1.92 2.00 1.68 1.27 0.97 0.76 0.59 0.46 0.37 0.32 0.31 0.34 0.41 0.52 0.67 0.86 1.10 1.46 1.88 2.06 1.58 8.10 3.86 1.72 1.23 0.91 0.69 0.50 0.36 0.25 0.18 0.13 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.08 0.11 0.15 0.22 0.31 0.45 0.64 0.87 1.19 1.72 2.38 3.07 2.10 1.71 1.83 1.58 1.28 1.00 0.78 0.61 0.48 0.38 0.33 0.32 0.35 0.43 0.54 0.69 0.88 1.13 1.42 1.73 1.85 1.45 2.86 2.70 1.96 1.42 1.01 0.75 0.53 0.37 0.26 0.18 0.13 0.09 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.08 0.12 0.16 0.23 0.34 0.47 0.68 0.94 1.29 1.84 2.51 3.23 2.19 1.67 1.80 1.57 1.28 1.01 0.79 0.62 0.49 0.39 0.33 0.32 0.35 0.43 0.55 0.69 0.89 1.13 1.42 1.70 1.81 1.42 3.05 2.86 2.09 1.54 1.10 0.80 0.57 0.40 0.28 0.20 0.14 0.10 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.09 0.13 0.18 0.26 0.37 0.52 0.73 0.98 1.30 1.78 2.42 2.78 2.01 1.83 1.92 1.63 1.27 0.98 0.77 0.60 0.47 0.38 0.32 0.31 0.34 0.42 0.53 0.67 0.87 1.12 1.45 1.81 1.97 1.53 2.59 2.63 2.06 1.51 1.12 0.85 0.62 0.44 0.31 0.21 0.15 0.11 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.09 0.13 0.19 0.28 0.41 0.57 0.77 1.02 1.33 1.74 2.20 2.39 1.81 2.14 2.20 1.75 1.29 0.97 0.76 0.58 0.45 0.36 0.31 0.30 0.33 0.40 0.51 0.65 0.85 1.11 1.50 2.02 2.29 1.71 2.21 2.32 1.97 1.51 1.16 0.88 0.66 0.48 0.34 0.23 0.16 0.11 0.08 0.05 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.07 0.10 0.14 0.20 0.29 0.42 0.59 0.79 1.05 1.37 1.73 2.07 2.18 1.68 2.58 2.44 1.82 1.36 0.98 0.74 0.56 0.43 0.35 0.30 0.30 0.32 0.38 0.49 0.65 0.85 1.14 1.60 2.14 2.72 1.91 2.01 2.17 1.90 1.54 1.19 0.91 0.69 0.51 0.35 0.24 0.16 0.11 0.08 0.06 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.07 0.10 0.14 0.19 0.29 0.42 0.59 0.79 1.04 1.36 1.73 2.10 2.22 1.72 2.52 2.41 1.80 1.34 0.98 0.74 0.56 0.43 0.35 0.31 0.30 0.32 0.38 0.49 0.65 0.85 1.13 1.59 2.13 2.68 1.88 2.05 2.21 1.91 1.54 1.19 0.91 0.68 0.50 0.35 0.24 0.16 0.11 0.08 0.05 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.09 0.13 0.19 0.27 0.40 0.55 0.76 1.00 1.31 1.74 2.28 2.48 1.87 2.08 2.12 1.74 1.28 0.97 0.76 0.58 0.45 0.36 0.32 0.31 0.33 0.40 0.51 0.66 0.85 1.10 1.49 2.00 2.23 1.68 2.30 2.41 2.01 1.51 1.15 0.87 0.65 0.47 0.33 0.22 0.16 0.11 0.08 0.05 0.04 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.06 0.09 0.12 0.17 0.25 0.36 0.51 0.71 0.97 1.29 1.81 2.46 2.95 2.07 1.80 1.89 1.62 1.27 0.98 0.77 0.60 0.47 0.38 0.32 0.31 0.34 0.42 0.53 0.68 0.87 1.12 1.44 1.79 1.93 1.50 2.71 2.73 2.08 1.52 1.12 0.83 0.60 0.43 0.30 0.21 0.15 0.10 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.08 0.11 0.16 0.22 0.32 0.46 0.66 0.92 1.28 1.85 2.52 3.30 2.20 1.66 1.79 1.57 1.28 1.01 0.78 0.62 0.49 0.39 0.33 0.32 0.35 0.43 0.55 0.70 0.89 1.13 1.42 1.70 1.80 1.42 3.04 2.89 2.10 1.54 1.08 0.78 0.55 0.39 0.27 0.19 0.13 0.10 0.07 0.05 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.08 0.11 0.15 0.21 0.30 0.44 0.61 0.84 1.14 1.64 2.29 2.88 1.99 1.73 1.85 1.59 1.28 1.00 0.78 0.61 0.48 0.38 0.33 0.32 0.35 0.43 0.54 0.68 0.88 1.12 1.43 1.74 1.87 1.46 2.63 2.58 1.89 1.36 0.98 0.72 0.52 0.37 0.25 0.18 0.13 0.09 0.06 0.04 0.03 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.07 0.10 0.14 0.20 0.29

Text truncated. Open the original for the full document.

Source: City of Franklin website. First collected Nov 15, 2026.