RecordWell Data

Historic Preservation / Design Review Commission — Agenda Packet

City of Stevens Point · Portage County · Historic Preservation and Design Review Commission · meeting of Apr 16, 2025 · Agenda packets

Open the original document More from City of Stevens Point

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

AGENDA HISTORIC PRESERVATION/ DESIGN REVIEW COMMISSION Members • Chair Tim Siebert • Vice Chair Peter Munck • Alderperson Marc Christianson • Barry Calnan • Carol Molepske • Janet Jurgella Finn (Alternate 1) • Dan Kryst (Alternate 2) Date and Time: April 16, 2025 5:00 PM Location: Community Room 933 Michigan Avenue, Stevens Point, WI OR Zoom Teleconferencing Meeting ID: 829 1409 6315 Passcode: 238967 By Computer: https://us02web.zoo m.us/j/82914096315?pwd=ZkBoY I57FvrEUtnpwO2FKqxiqg1vBq.1 By Phone: +1-312-626-6799 (US Chicago) PLEASE TAKE NOTICE that any person who has special needs while attending these meetings or needs agenda materials for these meetings should contact the City Clerk as soon as possible to ensure that a reasonable accommodation can be made. The City Clerk can be reached by telephone at (715) 346-1569 or by mail at 1515 Strongs Avenue, Stevens Point, WI 54481. Maps further defining the above area(s) may be obtained from the City of Stevens Point Department of Community Development, 1515 Strongs Avenue, Stevens Point, WI 54481, or by calling (715) 346-1567, during normal business hours. PLEASE TAKE FURTHER NOTICE that a quorum of the Common Council may be in attendance at this meeting. Opening Section: 1. Roll Call Discussion and Possible Action on: 2. Report of the March 24, 2025 meeting of the Historic Preservation / Design Review Commission. 3. A request to remove the mural on the west elevation of the building located at 817 Clark Street (Parcel ID 281240832201412), consistent with Ch. 22.07(3). 4. Public Hearing and action on a request from the City of Stevens Point to amend Section 22.04 of the Revised Municipal Code of the City of Stevens Point. Said request outlines the approval process for historic structures, properties and districts to be nominated on the State and National Register of Historic Places. 5. A request from James Lucas, representing Amethyst Main LLC, for a design review to perform exterior improvements on the building located at 968 Main Street (Parcel ID 281240832201526), consistent with Ch. 22.05(2). Page 1 of 39 PLEASE TAKE NOTICE that any person who has special needs while attending these meetings or needs agenda materials for these meetings should contact the City Clerk as soon as possible to ensure that a reasonable accommodation can be made. The City Clerk can be reached by telephone at (715) 346-1569 or by mail at 1515 Strongs Avenue, Stevens Point, WI 54481. Maps further defining the above area(s) may be obtained from the City of Stevens Point Department of Community Development, 1515 Strongs Avenue, Stevens Point, WI 54481, or by calling (715) 346-1567, during normal business hours. PLEASE TAKE FURTHER NOTICE that a quorum of the Common Council may be in attendance at this meeting. 6. A request from Jason Bacher, representing Leon Ayers, for a design review to perform storefront improvements on the building located at 1044 Main Street (Parcel ID 281240832202924), consistent with Ch. 22.05(2). 7. A request from David Ladick to paint the north-facing wall of the building located at 1216 Strongs Avenue (Parcel ID 281240832202932), consistent with Ch. 22.05(2). Closing Section: 8. Adjourn Page 2 of 39 Page 1 of 2 REPORT OF THE HISTORIC PRESERVATION / DESIGN REVIEW COMMISSION March 24, 2025 – 5:00 PM 933 Michigan Ave, Stevens Point, WI 54481 PRESENT: Chair Siebert, Alderperson Christianson, Commissioner Calnan & Commissioner Kryst EXCUSED: Vice Chair Munck, Commissioner Molepske, Commissioner Finn ALSO PRESENT: Associate Planner/Zoning Administrator Kuhn INDEX: Opening Section: 1. Roll Call Discussion and Possible Action on the Following: 2. Report of the January 27, 2025 meeting of the Historic Preservation / Design Review Commission. 3. A request from Katie Bingham, representing Michael O'Meara, for a design review to replace an existing window utilizing a different muntin pattern on the property located at 1809 Clark Street (Parcel ID 281240832102705), consistent with Ch. 22.05(2). 4. A request from the City of Stevens Point to amend program requirements of the Downtown Facade Improvement Grant Program. 5. Staff Update: • Designation of properties onto the National Register of Historic Places. Closing Section: 6. Adjourn Opening Section: 1. Roll Call Present: Siebert, Christianson, Calnan & Kryst Excused: Munck, Molepske & Finn Discussion and Possible Action on the Following: 2. Report of the January 27, 2025 meeting of the Historic Preservation / Design Review Commission. Motion by Alderperson Christianson to approve the January 27, 2025 minutes of the Historic Preservation / Design Review Commission; seconded by Commissioner Calnan. Motion carried 4-0. 3. A request from Katie Bingham, representing Michael O'Meara, for a design review to replace an existing window utilizing a different muntin pattern on the property located at 1809 Clark Street (Parcel ID 281240832102705), consistent with Ch. 22.05(2). Page 3 of 39 Page 2 of 2 Associate Planner / Zoning Administrator Kuhn provided a summary of the design review request. Motion by Alderperson Christianson to approve a request from Katie Bingham, representing Michael O'Meara, for a design review to replace an existing window utilizing a different muntin pattern on the property located at 1809 Clark Street (Parcel ID 281240832102705), subject to the following conditions: 1. Caulking shall be maintained when installing the new window. 2. A sound paint film shall always be applied to the window. 3. A building permit shall be obtained prior to installing the window. Seconded by Commissioner Kryst. Motion carried 4-0. 4. A request from the City of Stevens Point to amend program requirements of the Downtown Facade Improvement Grant Program. Associate Planner / Zoning Administrator Kuhn provided a summary of the proposed changes to the Downtown Façade Improvement Grant Program. A lengthy conversation took place on what entities should review and approve grant disbursements. The Commission ultimately agreed that grant requests can be reviewed and approved by both the Designated Agent for the Commission and the Commission Chair. Motion by Commissioner Calnan to approve the request to amend program requirements of the Downtown Facade Improvement Grant Program; seconded by Commissioner Kryst. 5. Staff Update: Designation of properties onto the National Register of Historic Places. Associate Planner / Zoning Administrator Kuhn provided a summary of future changes to the City’s Historic Preservation Ordinance regarding the City’s role of designating buildings, sites and districts onto the National Register of Historic Places. A public hearing will be scheduled for an April Commission meeting where the Commission will consider an ordinance amendment request outlining these changes. No action was taken. Closing Section: 5. Adjourn Meeting adjourned at 5:20 PM. A recording of this meeting can be viewed/heard at: https://stevenspoint.com/365/AgendasMinutesVideos Page 4 of 39 City of Stevens Point 1515 Strongs Avenue Stevens Point, WI 54481-3594 Department of Community Development Adam Kuhn Associate Planner Zoning Administrator Ph: (715) 346-1567 Fax: (715) 346-1498 www.stevenspoint.com Open Records Rider: The City of Stevens Point is subject to Wisconsin Statutes relating to public records. Communication, such as this document, sent or received by City employees are subject to these laws. Unless otherwise exempted from the public records law, senders and receivers of City communication should presume that the communications are subject to rel ease upon request, and to state record retention requirements. Page 1 of 2 MEMORANDUM To: Historic Preservation / Design Review Commission From: Adam Kuhn, AICP Associate Planner / Zoning Administrator Date: April 16, 2025 RE: Amendment to Historic Preservation Ordinance – Nomination of Buildings, Sites & Districts onto the National Register of Historic Places ------------------- Background: For several decades, the City has been a proud member of the Wisconsin Certified Local Government Program – a program that is administered by the State Historic Preservation Office. Earlier this year, the State Historic Preservation Office announced a directive to all certified local governments pertaining to a requested ordinance amendment for National Register nominations. Currently, the City has no required role for the designation of buildings, sites & districts onto the National Register of Historic Places. Typically, the State Historic Preservation Office allows municipal historic preservation commissions to comment when any nominations are submitted in their jurisdiction – a process that the City has done in the past, most recently the nomination of the Sisters of St. Joseph of the Third Order of St. Francis grounds earlier this decade. The State Historic Preservation Office is requesting the following changes be incorporated into the City’s Historic Preservation Ordinance: • Require the City’s Historic Preservation / Design Review Commission to provide an opportunity for public comment on the nomination of buildings and land in city limits to the National Register of Historic Places. • Require the City’s Historic Preservation / Design Review Commission to vote on whether a proposed nomination meets the eligibility criteria for listing on the National Register of Historic Places. • Require the Mayor of the City of Stevens Point to make a determination on whether a proposed nomination meets the eligibility criteria for listing on the National Register of Historic Places. Page 5 of 39 stevenspoint.com The attached resolution highlights the proposed insertion into the City’s Historic Preservation Ordinance. If the Commission recommends approval of these changes, it will be brought to the Common Council on April 21st for final consideration. If you have any questions, please let me know. Page 6 of 39 ORDINANCE AMENDING THE REVISED MUNICIPAL CODE OF THE CITY OF STEVENS POINT, WISCONSIN [Chapter 22 of the Revised Municipal Code – Historic Preservation & Design Review – Proposed Designations onto the National Register of Historic Places] The Common Council of the City of Stevens Point, Portage County, Wisconsin, do ordain as follows: SECTION I: That Section 22.04 of the Historic Preservation and Design Review Ordinance of the Revised Municipal Code of the City of Stevens Point shall be amended as follows: Local and National Historic Structure, Historic Site, and Historic District Designation Criteria 1) For purposes of this ordinance, a local historic structure, historic site, or historic district designation may be placed on any site, natural or improved, including any building, improvement or structure located thereon, or any area of particular historic, architectural, archeological or cultural significance to the city such as historic structures, sites, or districts which: a) Exemplify or reflect the broad cultural, political, economic or social history of the nation, state or community; or b) Are identified with historic personages or with important events in national, state or local history; or c) Embody the distinguishing characteristics of an architectural type or specimen inherently valuable for a study of a period, style, method of construction, or of indigenous materials or craftsmanship; or d) Are representative of the notable work: of a master builder, designer or architect who influenced his age; or e) Have yielded, or may be likely to yield, information important to prehistory or history. Page 7 of 39 The commission shall adopt specific operating guidelines for historic structure, historic site, and historic district designation providing such are in conformance with the provisions of this ordinance. 2) For purposes of this ordinance, the Commission encourages the nomination of buildings, sites and districts onto the National Register of Historic Places. When an applicant submits nomination papers to the State Historic Preservation Office to designate buildings, sites and districts in city limits to the National Register of Historic Places, the following shall be met: a) The Commission shall conduct a public hearing and, by majority vote, determine whether the proposed nomination meets the United States National Park Service’s eligibility criteria for listing onto the National Register of Historic Places. Such findings shall be sent to the Wisconsin Historic Preservation Office. b) The Mayor of the City of Stevens Point shall make a recommendation on whether the proposed nomination meets the United States National Park Service’s eligibility criteria for listing onto the National Register of Historic Places. Such findings shall be sent to the Wisconsin Historic Preservation Office. SECTION II: That this ordinance shall take effect upon passage and publication. Approved: _____________________________ Mike Wiza, Mayor Attest: _____________________________ Kari Yenter, City Clerk Dated: April 16, 2025 Adopted: April 21, 2025 Drafted By: Adam Kuhn Return To: City Clerk Page 8 of 39 Page 9 of 39 Page 10 of 39 City of Stevens Point 1515 Strongs Avenue Stevens Point, WI 54481-3594 Department of Community Development Adam Kuhn Associate Planner Zoning Administrator Ph: (715) 346-1567 Fax: (715) 346-1498 www.stevenspoint.com Open Records Rider: The City of Stevens Point is subject to Wisconsin Statutes relating to public records. Communication, such as this document, sent or received by City employees are subject to these laws. Unless otherwise exempted from the public records law, senders and receivers of City communication should presume that the communications are subject to release upon request, and to state record retention requirements. Page 1 of 1 MEMORANDUM To: Historic Preservation / Design Review Commission From: Adam Kuhn, AICP Associate Planner / Zoning Administrator Date: April 16, 2025 RE: Design Review – 968 Main Street ------------------- Background: The property owner at 968 Main Street is requesting a design review to replace second story windows on the east elevation of the building (adjacent to Third Street). The proposed window replacement is part of a larger interior remodel of the second floor to create one residential unit. As shown in the attached plans, the proposal is to replace four existing windows with aluminum clad wood single-hung windows. The purpose of this project requiring Commission approval is twofold – 1.) the size of the southernmost window on the east elevation of the building will be slightly smaller to ensure that appropriate separation exists between the window and the sill line directly above the storefront windows, and 2.) the muntin pattern for three of the windows are currently different than what is proposed. Overall, I am in support of the proposed changes. The change in muntin patterns with the windows better achieves uniformity in window design with the other windows on the south and east elevations of the building. Plus, the City’s Historic Preservation Plan advocated for the reintroduction of housing units on the second floor of our historic buildings, and ensuring that historic preservation supports such an aspiration. This project meets the Plan’s goal. If you have any questions, please let me know. Page 11 of 39 HISTORIC PRESERVATION/ DESIGN REVIEW COMMISSION City of Stevens Point Community Development Department 1515 Strongs Avenue, Stevens Point, WI 54481 P: (715) 346-1567 F: (715) 346-1498 communitydevelopment@stevenspoint.com http://stevenspoint.com Application for Design Review Page 1 of 2 APPLICATION FOR DESIGN REVIEW ADMINISTRATIVE SUMMARY (Staff Use Only) Application # Date Submitted Assigned Case Manager Associated Permits or Applications (if any) Pre-Application Conference Date Decision Date Reviewed Staff Signature Notes: APPLICANT/CONTACT INFORMATION APPLICANT INFORMATION CONTACT INFORMATION (Same as Applicant? ) Applicant Name Contact Name Address Address City, State, Zip City, State, Zip Telephone Telephone Fax Fax Email Email OWNERSHIP INFORMATION PROPERTY OWNER OF RECORD 1 INFORMATION (Same as Applicant? ) PROPERTY OWNER OF RECORD 2 INFORMATION (If Needed) Owner’s Name Owner’s Name Address Address City, State, Zip City, State, Zip Telephone Telephone Fax Fax Email Email PROJECT SUMMARY Subject Property Location [Please Include Address and Assessor’s Identification Number(s)] Parcel 1 Parcel 2 Parcel 3 Legal Description of Subject Property Area of Subject Property (Acres/Sq Ft) Area of Building or Structure (Sq Ft) Page 12 of 39 Application for Design Review Page 2 of 2 Current Zoning District(s) Current Historic District(s) - Local, State, National Designated Future Land Use Category Current Use of Property Proposed Use of Property Briefly describe the proposed building, structure construction, reconstruction or exterior alteration. Please also provide rationale for the design review request, along with the time schedule (if any) for the project. (Use additional pages if necessary) Will the proposed work detrimentally change, destroy or adversely affect any exterior architectural features of the improvement upon which said work is to be done? Explain you answer. Does the proposed work match and harmonize with the external appearance of adjacent neighboring improvements. Explain your answer. Does the proposed work conform to the objectives of the historic preservation plan for said district (if any)? Explain you answer. Does the proposed work conform with the architectural design guidelines with emphasis on contextual issues including compatibility of size, volume proportions, rhythm, materials, detailing, colors, and expressiveness? (Historic Design Guidelines can be found at www.stevenspoint.com) Explain you answer. EXHIBITS Letter to District Alderperson (www.stevenspoint.com/Directory) Additional Exhibits If Any (List): Photographs of Building or Structure Renderings or Elevations Site Plan (for additions, and new construction) CERTIFICATION AND SIGNATURE By my signature below, I certify that the information contained in this application is true and correct to the best of my knowledge at the time of the application. I acknowledge that I understand and have complied with all of the submittal requirements and procedures and that this application is a complete application submittal. I further understand that an incomplete application submittal may cause my application to be deferred to the next posted deadline date. Signature of Applicant Date Signature of Property Owner(s) Date Page 13 of 39 3rd STREET MAIN STREET PROJECT AREA ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved PARCEL ID: 968 Main Street, Stevens Point, WI 54481 Schultz Properties Interior Alteration for T100 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 SITE PLAN & SHEET INDEXSchultz Properties 281240832201526 N 0' 20'0' 5' 10' CODE DATA (a) At least 2 exits shall be provided from the second floor. At least one of the exits shall be a stairway or ramp and lead to the first floor or discharge to grade. (b) Windows that comply with sub. (6) may be provided in each second floor bedroom or in another location on the second floor if there are no bedrooms on that floor in lieu of the second exit from that floor. SPS 321.03(2) Exits From The Second Floor. TYPE 3 B, 980 SF Proposed Level 3 Alteration Wisconsin Enrolled, 2015 International Building Code Wisconsin Enrolled, 2015 International Existing Building Code Wisconsin Enrolled, Safety & Professional Services, SPS 321 & SPS 322 Mercantile, Group M, 1,125 square feet, 1 Floor Business, Group B, 980 square feet, 1 Floor Project Building Area Existing Occupancy Classification - 303.1 Governing Code Type of Construction - TABLE 601 TITLE T100 SITE PLAN & SHEET INDEX ARCHITECTURE A001 LIFE SAFETY PLAN A101 PROPOSED FIRST FLOOR PLAN A102 PROPOSED SECOND FLOOR PLAN A103 BATHROOM ELEVATIONS A201 EXTERIOR BUILDING ELEVATIONS A301 BUILDING SECTIONS A700 INTERIOR 3D RENDERS ELECTRICAL E101 ELECTRICAL POWER & LIGHTING PLANS SHEET INDEX EXISTING STRUCTURE CONSIDERED HISTORIC BUILDING INSIDE STEVENS POINT DOWTOWN HISTORIC DISTRICT 1" = 10'-0"1 1SITE PLANSITE PLAN WINDOW AREA SHALL EQUAL 8% OF FLOOR AREA OF THE BEDROOM, WITH 4% OF FLOOR AREA OPENABLE. SPS 321.05 Natural Light and Natural Ventilation INSTALL CARBON MONOXIDE DETECTORS AT EACH BEDROOM DOOR SPS 321.097 Carbon Monoxide Alarms (3) (3)(3.)(b.) - GUARDS SHALL BE CONSTRUCTED TO PREVENT THE THROUGH-PASSAGE OF A SPHERE WITH A DIAMETER OF 4 3/8 INCHES, WHEN APPLYING A FORCE OF 4 POUNDS. (3) (3)(4.)(a.) - NEW DECK GUARDRAILS & HANDRAILS SHALL RESIST 200 LB LOAD (3) (3)(5.)(b)(a.) - HANDRAILS SHALL BE LOCATED AT LEAST 30 INCHES, BUT NO MORE THAN 38 INCHES ABOVE THE NOSING OF THE TREADS. (TYPICAL: 36" ABOVE FLOOR) SPS 321.04 Stairways and Elevated Areas Mercantile - M, 1,125 square feet 1st Floor Single Family Dwelling - 980 square feet 2nd Floor Proposed Occupancy Classification - 303.1 STAIRS = 36" Min. : 39" PROVIDED DOORS = Min. 36" Wide by Min. 80" High: 36" x 80" PROVIDED. SPS 321.03 Exits SPS 321.04 Stairways & Elevated Areas Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date SEPERATED OCCUPANCIES 508.4 (Group M)|(R) NS = 2-HR Fire Seperation - Table 508.4 02.17.2025 Page 14 of 39 REF. WH UPUP FLOOR/CEILING HORIZONTAL SEPERTATION - 1" NOMINAL SOLID WOOD FLOOR DECK - 2"x10" SPF FLOOR FRAMING 16" O.C. - 5/8" TYPE X FIRECODE GYP WALL BOARD UL FLR/CLG ASSEMBLY UL L556 - 3 LAYER 5/8" TYPE-X GWB - 1 LAYER 7/8" HAT CHANNEL - 1 LAYER 5/8" TYPE-X GWB 2-HR WALL ASSEMBLY UL U301 UL U301 STC: 54 FIRE RATING: 2 HOURS GYPSUM PANELS: TWO LAYERS 5/8" TYPE-X FIRECODE GYPSUM WALL BOARD RESILIENT CHANNEL 1/2" RESILIENT CHANNEL, 25 GA, 24" O.C. WOOD STUD 2"x4" WOOD STUDS, 16" O.C. 1'-4" 1'-4" 1'-4" 1'-4" 6 1/2" NEW 2-HR SEPARATION WALL EXISTING EXTERIOR MASONRY WALL. NEW 2-HR SEPARATION WALL 2-HR FLR/CLG ASSEMBLY AREA EXISTING EXTERIOR MASONRY WALL. NEW 2-HR SEPARATION WALL NEW 2-HR SEPARATION WALL 5 A001 - --- 2-HR WALL ASSEMBLY, UL U301 EXIST ROOF DECK & FRAMING 1236 3rd St1236 3rd St 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A001 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 LIFE SAFETY PLANSchultz Properties Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 1" = 1'-0"3 32HR FLOOR/CEILING SEPARATION2HR FLOOR/CEILING SEPARATION 0' 2'6" 1' 1" = 1'-0"4 42HR SEPARATION WALL2HR SEPARATION WALL 1/8" = 1'-0"2 2SECOND FLOOR FIRE SEPARATION PLANSECOND FLOOR FIRE SEPARATION PLAN 0' 8'0' 2' 4' N 1/8" = 1'-0"1 1FIRST FLOOR FIRE SEPARATION PLANFIRST FLOOR FIRE SEPARATION PLAN 0' 8'0' 2' 4' 0' 2'6" 1' 1" = 1'-0"5 52-HR PARAPET WALL DETAIL2-HR PARAPET WALL DETAIL 0' 2'6" 1' Page 15 of 39 UP REMOVE EXISTING FINISHES & REPLACE WITH REQ'D FINISHES FOR 2-HR SEPERATION, UL 301 NEW 2-HR SEPERATION WALL, UL 301 EXISTING GROUP M OCCUPANCY NEW 3'-0" x 6'-8" ENTRY DOOR 1236 3rd St NEW 2-HR SEPERATION WALL, UL 301 A101 3 REMOVE EXISTING DOOR & REPLACE WITH NEW 2-HR SEPERATION, UL 301 EXISTING GROUP M OCCUPANCY 1236 3rd St REMOVE EXISTING FINISHES & REPLACE WITH REQ'D FINISHES FOR 2-HR SEPERATION, UL 301 3'-8 1/2" 3'-8 1/2" 3'-8 1/2" 1'-5 1/2"1'-0 1/2" 4'-2" 2'-5 1/2" 1/8" = 1'-0"2 2FIRST FLOORFIRST FLOOR 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A101 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 PROPOSED FIRST FLOOR PLANSchultz Properties 16'0' 4' 8' SHEET NOTE: REMOVE ALL WALLS DOORS & WINDOWS SHOWN DASHED TO BE DEMOLISHED EXISTING PARTITION TO REMAIN NEW PARTITION WALL KEY Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 1/8" = 1'-0"1 1DEMO FIRST FLOORDEMO FIRST FLOOR 16'0' 4' 8' N N 1/2" = 1'-0"3 3FIRST FLOOR - STOREFRONT DET PLANFIRST FLOOR - STOREFRONT DET PLAN 2' 4'0' 1' N PER TABLE IBC 706.4 EXISTING PARTY WALL IS REQUIRED TO BE 3-HOUR RATED. PER TABLE IBC 721.1 (2) 3-1.3 EXISTING 24" MASONRY UNIT EXCEEDS 3-HOUR RATING 1 Page 16 of 39 DN REF. WH 5'-6 1/2" A A A B BEDROOM KITCHEN LIVING BATH STORAGE 3'-4"12'-2"8'-5 1/2"15'-0" 2'-1" W/D 10'-4 1/2" 3'-8" 5'-10" 3'-1" 2'-1" 12'-3 1/2" 3'-4" 3'-10 1/2" 34 3 2 2 1 3 C NEW ALUMINUM CLAD SINGLE HUNG WINDOWS FURN. 1 A301 5'-10" 3 A301 16'-2" - --- REMOVE PARTITIONS, DOORS & FIXTURES SHOWN DASHED REMOVE EXISTING WINDOWS SHOWN DASHED, REPLACE WITH ALUMINUM CLAD WOOD SINGLE HUNG WINDOWS REMOVE EXISTING WINDOWS SHOWN DASHED, REPLACE WITH NEW ALUMINUM CLAD WOOD WINDOWS DEMO CLG FINISH REMOVE EXIST LATH & PLASTER @ EXT WALLS REMOVE FIXTURES & STEPS REMOVE STEP & LEVEL FLOOR DEMO EXIST WALL & REPLACE W/ 2-HR WALL DEMO EXIST CEILING & ROOF FRAMING, SEE: A301 2'-0" 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A102 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 PROPOSED SECOND FLOOR PLANSchultz Properties 1/4" = 1'-0"2 2PROPOSED SECOND FLOORPROPOSED SECOND FLOOR N 1/4" = 1'-0"1 1DEMO SECOND FLOORDEMO SECOND FLOOR SHEET NOTE: REMOVE ALL WALLS DOORS & WINDOWS SHOWN DASHED TO BE DEMOLISHED EXISTING PARTITION TO REMAIN NEW PARTITION WALL KEY 0' 8'0' 2' 4' 0' 8'0' 2' 4' Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date DOOR SCHEDULE MARK SIZE TYPE COUNT A 36" x 80" Interior Single Swing 5 B 60" x 84" Bifold-4 Panel 1 C 36" x 80" Entry Single Swing 3 D 36" x 80" Exterior Single - One Lite 1 WINDOW SCHEDULE MARK SIZE TYPE COUNT 1 36" x 74" Window-Single-Hung 1 2 36" x 76" Window-Single-Hung 2 3 41" x 80" Window-Single-Hung 3 4 83" x 80" Window-Fixed 1 N PER TABLE IBC 706.4 EXISTING PARTY WALL IS REQUIRED TO BE 3-HOUR RATED. PER TABLE IBC 721.1 (2) 3-1.3 EXISTING 24" MASONRY UNIT EXCEEDS 3-HOUR RATING 1 Page 17 of 39 REF. A1033 2 2'-1" 4'-0"1'-6" 1'-8" 5'-6 1/2" 2'-6" A103 6 5 7 2'-8"3'-8"2'-1"1'-4" 2'-1"4'-3" 12'-7 1/2" 4'-0" 2'-8" 3'-0" 12'-9" DW DISHWASHER 3'-0" 3'-6" 1'-4" 1'-6" 2'-6" 2'-1" 2'-1" 3'-0" 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A103 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 BATHROOM ELEVATIONSSchultz Properties Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 1/2" = 1'-0"2 2Bath Elevation - EastBath Elevation - East 1/2" = 1'-0"3 3Bath Elevation - WestBath Elevation - West 1/2" = 1'-0"1 1BATH PLANBATH PLAN 1/2" = 1'-0"4 4KITCHEN PLANKITCHEN PLAN 1/2" = 1'-0"5 5Kitchen Elevation - NorthKitchen Elevation - North 1/2" = 1'-0"6 6Kitchen Elevation - SouthKitchen Elevation - South 1/2" = 1'-0"7 7Kitchen Elevation - EastKitchen Elevation - East 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' Page 18 of 39 3 2 2 15'-10 3/4" 3'-4 3/4" ALIGN NEW HORIZONTAL MULLIONS WITH EXISTING DOOR HEAD 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A201 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 EXTERIOR BUILDING ELEVATIONSSchultz Properties Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 1/4" = 1'-0"1 1EXISTING EAST ELEVATIONEXISTING EAST ELEVATION 1/4" = 1'-0"3 3EXISTING SOUTH ELEVATIONEXISTING SOUTH ELEVATION 0' 8'0' 2' 4' 0' 8'0' 2' 4' SHEET NOTE:SHEET NOTE: ALTERATIONS TO BE DONE ON SECOND LEVEL ALTERATIONS TO BE DONE ON SECOND LEVEL & ENTRY LEVEL TO DWELLING ONLY .& ENTRY LEVEL TO DWELLING ONLY . 1/4" = 1'-0"2 2PROPOSED EAST ELEVATIONPROPOSED EAST ELEVATION 0' 8'0' 2' 4' 1/4" = 1'-0"4 4SOUTH ELEV. OPT 2SOUTH ELEV. OPT 2 0' 8'0' 2' 4' SAFETY GLAZNG SHALL BE INSTALLED IN ALL OF THE FOLLOWING CONDITIONS: - SIDELITES WITHIN 24" OF ENTRY DOORS SAFETY GLAZING SHALL BE INSTALLED AT WINDOWS WHERE ALL OF THE FOLLOWING CONDITIONS ARE MET. - EXPOSED AREA OF GLAZING EXCEEDS 9 SQ FT. - THE BOTTOM EDGE OF WINDOW IS LESS THAN 18" ABOVE THE FLOOR - THE TOP EDGE OF THE WINDOW IS GREATER THAN 36" ABOVE THE FLOOR A WALKING SURFACE IS WITHIN 36" HORIZONTALLY FROM THE WINDOW. SAFETY GLAZING SHALL BE IDENTIFIED AS SUCH BY MANUFACTURER 1 IEBC 908.1 APPLIES TO NEW CONSTRUCTION ONLY INSIDE AIR FILM .68 IECC 402.1 PRESCRIPTIVE METHOD FOR THERMAL ENVELOPE ASSEMBLIES BUILDING USES U-VALUE BASED METHOD, C402.1.4 CLIMATE ZONE 6 ATTIC INSULATION = U-0.021 WOOD FRAMED WALLS, U-0.051 COMPONENT R-VALUE @ CAVITY COMPONENT WALLS BELOW GRADE U-0.119 WOOD FRAMED FLOORS U-0.033 OPAQUE SWINGING DOORS U-0.37 ATTIC INSULATION = R-47.62 WOOD FRAMED WALLS, R-19.60 WALLS BELOW GRADE R-8.40 WOOD FRAMED FLOORS R-30.30 OPAQUE SWINGING DOORS R-2.27 BUILDING USES U-VALUE BASED METHOD, C402.4 CLIMATE ZONE 6 OPERABLE FENESTRATION U-0.43 SHADING COEFFICIENT 0.40 AIR LEAKAGE 0.3 PER 402.5.2 MANUFACTURER'S DATA STICKER SHALL BE LEFT ON WINDOWS AND DOORS UNTIL FINAL INSPECTION OPERABLE FENESTRATION R-2.32 OWENS CORNING R-21 FACED FIBERGLASS BATTS OR APPROVED EQUAL WITH SIMILAR ENERGY EFFICENCY DATA INSIDE AIR FILM 1/2" GYP WALL BRD STUD CAVITY 1/2" OSB SHEATHING 1/2" SIDING OUTSIDE AIR FILM 1/2" GYP WALL BRD STUD 1/2" OSB SHEATHING 1/2" SIDING OUTSIDE AIR FILM .68 R-VALUE @ STUD .45 20 .75 .81 .17 TOTAL 22.86 .68 .45 6.88 .75 .81 .17 TOTAL 9.74 2"x6", 16" OC TOTAL WALL R-VALUE = .093 x (.102) + .907 (.043) = .0094 + .0390 = .0484 WALL U-VALUE % OF STUDU of STUD% of CAVITYU of CAVITY KOLBE WINDOWS & DOORS or APPROVED EQUAL DOORS AND WINDOWS WITH SIMILAR OR BETTER ENERGY EFFICIENCY DATA WILL BE APPROVED U-VALUE @ STUD U-VALUE @ CAVITY .043 .102 MASONRY WALLS, U-0.075 MASONRY WALLS, R-13.3 C.I. OPAQUE NON-SWINGING DOORS U-0.31 OPAQUE NON-SWINGING DOORS R-3.22 Page 19 of 39 12'-2" 8'-10" 4 A001 NEW R-49 BLOWN-IN CELLUOSE INSULATION NEW ALUMINUM CLAD SINGLE HUNG WINDOWS, W/ LOW-E, DOUBLE PANE, ARGON FILLED GLAZING, ALL FENESTRATION SHALL MEET OR EXCEED R-2.85. EXISTING EPDM MEMBRANE ROOFING EXISTING HEADERS TO REMAIN @ ALL WINDOW AND DOOR OPENINGS. TYPICAL INTERIOR FURRING WALL: - 1/2" GYPSUM WALL BOARD INTERIOR - POLYETHYLENE VAPOR BARRIER - 2"x4" STUD FRAMING, 16" OC - R-21 FIBERGLASS INSULATION NEW BATT INSULATION @ FLOOR & PLATE LINES, OPENINGS IN PLATES, CORNER STUD CAVITIES & AROUND DOOR & WINDOW ROUGH OPENING CAVITIES. EXISTING ROOF FRAMING NEW FLOOR/CEILING HORIZONTAL SEPERTATION - 1" NOMINAL SOLID WOOD FLOOR DECK - 2"x10" SPF FLOOR FRAMING 16" O.C. - 5/8" TYPE X FIRECODE GYP WALL BOARD UL FLR/CLG ASSEMBLY UL L556 NEW ALUMINUM CLAD SINGLE HUNG WINDOWS, W/ LOW-E, DOUBLE PANE, ARGON FILLED GLAZING, ALL FENESTRATION SHALL MEET OR EXCEED R-2.85. EXISTING HEADERS TO REMAIN @ ALL WINDOW AND DOOR OPENINGS. EXISTING LATHE & PLASTER FINISHES @ WALLS & CEILING TO BE REMOVED & REPLACED NEW 2-HR FLOOR/CEILING, UL 556 @ FIRST FLOOR. REMOVE LATH & PLASTER, INSTALL - 3 LAYER 5/8" TYPE-X GWB - 1 LAYER 7/8" HAT CHANNEL - 1 LAYER 5/8" TYPE-X GWB EXISTING EXTERIOR MASONRY WALL EXISTING EXTERIOR MASONRY WALL - --- 6'-8"1'-1 1/2" EXISTING ROOF STRUCTURE TO BE REMOVED & REPLACED EXISTING FLOOR STRUCTURE TO BE REMOVED & REPLACED LEVEL W/ TYP. FLOOR HEIGHT EXISTING PITCH EXISTING LATHE & PLASTER FINISHES @ WALLS & CEILING TO BE REMOVED & REPLACED 5'-2 69/128" NEW ROOF FRAMING - .060 FULLY ADHERED MEMBRANE - 1/2" HIGH DENSITY FIBERBOARD - 5/8" OSB SHEATHING 1 12 NEW R-49 BLOWN-IN CELLUOSE INSULATION NEW 2-HR STUD FRAMED WALL, UL U301: - 2 LAYER 5/8" TYPE-X GWB - POLYETHYLENE VAPOR BARRIER - 2"x6" STUD FRAMING, 16" OC - R-21 FIBERGLASS INSULATION - 1/2" RESILIENT CHANNEL, 25 Ga, 24" O.C. - 2 LAYER 5/8" TYPE-X GWB NEW FLOOR/CEILING HORIZONTAL SEPERTATION - 1" NOMINAL SOLID WOOD FLOOR DECK - 2"x10" SPF FLOOR FRAMING 16" O.C. - 5/8" TYPE X FIRECODE GYP WALL BOARD UL FLR/CLG ASSEMBLY UL L556 12'-7 1/2" 8'-11" 2" x 12" SPF JOIST, 24" O.C. 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A301 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 BUILDING SECTIONSSchultz Properties Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 1/2" = 1'-0"1 1CROSS SECTIONCROSS SECTION 1/2" = 1'-0"2 2EXISTING STORAGE SECTIONEXISTING STORAGE SECTION 1/2" = 1'-0"3 3PROPOSED STORAGE SECTIONPROPOSED STORAGE SECTION 2' 4'0' 1' 2' 4'0' 1' 2' 4'0' 1' Page 20 of 39 REF. UP WH 3 3F 3 3 GFIC DUPLEX OUTLET DUPLEX OUTLET QUADPLEX OUTLET 240 VOLT OUTLET TELE OR DATA OUTLET PAIR TELE OR DATA OUTLET 3D MH SINGLE POLE LIGHT SWITCH 3-WAY SWITCH MOTION SENSOR SWITCH DUAL SWITCH HUMIDISTAT 1/4" = 1'-0"1 1SECOND FLOOR ELECTRICAL PLANSECOND FLOOR ELECTRICAL PLAN 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. E101 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 ELECTRICAL POWER & LIGHTING PLANSSchultz Properties Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date 0' 8'0' 2' 4' N Page 21 of 39 715-572-2698 arccentralinc@outlook.com ARC CENTRAL LLC PROJECT NO. DATE REVISIONS © Arc Central LLC 2024 ARCHITECTURE, CONSTRUCTIONMANAGEMENT, INTERIOR DESIGN PROPOSED PLANS FOR COPYRIGHT © Arc Central LLC 2024 All Rights Reserved ALL DRAWINGS ARE TO THE SCALE SHOWN ON THE SHEETS. THEY ARE INTENDED TO BE PRINTED ON 24x36" SHEETS. IF THEY ARE PRINTED ON A DIFFERENT SIZE SHEET THE SCALE NEEDS TO BE ADJUSTED ACCORDINGLY. A700 24068 Dec 6th, 2024 968 Main Street, Stevens Point, WI 54481 INTERIOR 3D RENDERSSchultz Properties 3 33D Interior 33D Interior 3 2 23D Interior 23D Interior 2 1 13D Interior 13D Interior 1 Prelim. Plan 12.06.24 Const. Docs 01.22.25 Approval 2.1.25 Revision 1 4.3.25 Revision 2 Date Page 22 of 39 Page 23 of 39 Page 24 of 39 Page 25 of 39 Page 26 of 39 Page 27 of 39 Page 28 of 39 Page 29 of 39 City of Stevens Point 1515 Strongs Avenue Stevens Point, WI 54481-3594 Department of Community Development Adam Kuhn Associate Planner Zoning Administrator Ph: (715) 346-1567 Fax: (715) 346-1498 www.stevenspoint.com Open Records Rider: The City of Stevens Point is subject to Wisconsin Statutes relating to public records. Communication, such as this document, sent or received by City employees are subject to these laws. Unless otherwise exempted from the public records law, senders and receivers of City communication should presume that the communications are subject to rel ease upon request, and to state record retention requirements. Page 1 of 2 MEMORANDUM To: Historic Preservation / Design Review Commission From: Adam Kuhn, AICP Associate Planner / Zoning Administrator Date: April 16, 2025 RE: Design Review – 1044 Main Street ------------------- Background: The property owner at 1044 Main Street is requesting a design review to convert the existing storefront windows to thermal pane windows. As part of this window replacement, there are proposed to be changes to the sill line of the storefront windows. Such changes include adding an 18-inch hardwood decorative back at the two-foot mark, along with altering the appearance of the stiles that separate each window panel. The purpose of the proposed changes are to increase security for Lee Ayers, particularly due to the windows serving as a showcase of product offerings. The proposed improvements to the storefront windows would constitute a ‘major work’ per the Commission’s Design Guidelines, and would require Commission approval before moving forward. Overall, I am in support of the proposed changes particularly due to the interest in maintaining consistency between other storefronts along Main Street (e.g., the Opera House, the Wooden Chair, etc.). If you have any questions, please let me know. Page 30 of 39 stevenspoint.com Page 31 of 39 Page 32 of 39 Page 33 of 39 Page 34 of 39 Page 35 of 39 City of Stevens Point 1515 Strongs Avenue Stevens Point, WI 54481-3594 Department of Community Development Adam Kuhn Associate Planner Zoning Administrator Ph: (715) 346-1567 Fax: (715) 346-1498 www.stevenspoint.com Open Records Rider: The City of Stevens Point is subject to Wisconsin Statutes relating to public records. Communication, such as this document, sent or received by City employees are subject to these laws. Unless otherwise exempted from the public records law, senders and receivers of City communication should presume that the communications are subject to release upon request, and to state record retenti on requirements. Page 1 of 2 MEMORANDUM To: Historic Preservation / Design Review Commission From: Adam Kuhn, AICP Associate Planner / Zoning Administrator Date: April 16, 2025 RE: Design Review – 1216 Strongs Avenue ------------------- Background: The property owner at 1216 Strongs Avenue is requesting a design review to paint the north-facing wall of the building located on the subject property. According to Section 3.11(9) of the Commission’s Design Guidelines, exterior walls that were historically unpainted should not be painted. As Commissioner’s recall, this building wall was subject to a design review earlier this decade to paint a mural. The mural request was approved, and our mural guidelines at the time prioritized the application of murals on historically unpainted building walls. The approved mural will not be applied onto the building and, as such, the applicant is requesting to apply a solid color on this north-facing wall. A specific color has not been selected at this time, but the intention is to apply an “earth tone” color. Consistent with the remaining paint guidelines that apply to this building, my recommendation is to approve the design review request. Applying an earth tone color will better complement the other colors that are utilized on this building, and would better active the rear of this building – a concept that was prioritized as part of the City’s Historic Preservation Plan. As a condition of approval, I would recommend the following: • The applicant shall provide a final color to the Designated Agent for review and approval. • When applying paint, care should be given not to conceal the texture of the underlying building material. If you have any questions, please let me know. Page 36 of 39 stevenspoint.com Page 37 of 39 Page 38 of 39 Page 39 of 39

Source: City of Stevens Point website. First collected Nov 18, 2026.