Economic-Development-Commission-Special-Meeting-Agenda-Packet-Updated-9-30-2026.pdf
City of Franklin · Milwaukee County · meeting of Sep 30, 2026 · Agenda packets
Open the original document More from City of Franklin
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
Special Meeting of the Franklin Economic Development Commission (EDC)
Agenda
Franklin City Hall, Hearing Room
9229 W. Loomis Road, Franklin, Wisconsin
September 30, 2026 – 6:00 p.m.
Chairman Steve Bobowski
Cathleen Richard
Mike Barber
Barbara Wesener
Timothy Wachter
Alderwoman Michelle Eichmann
I. Call to Order and Roll Call
A. Pledge of Allegiance
II. Citizen Comment Period
III. Approve Proposal For The Fabrication And Installation Of A City Sign on an existing sign
monument at northwest corner of West Drexel Avenue and South 27th Street.
IV. Paleria Brothers LLC, 9848 S 57th St. (FLEX 2020 LLC, PROPERTY OWNER)
Minor site plan amendment to allow for photovoltaic (solar) panels for Paleria Brothers LLC, in
the City of Franklin Industrial Park. Photovoltaic (solar) panels as a utility feature require EDC
approval in accordance with Sec. 12.10(18) of Planned Development Legacy (PDL) 7.
V. Adjournment
Notice is given that a majority of the Common Council may attend this meeting to gather information about an Agenda item
over which they have decision making responsibility. This may constitute a meeting of the Council per State ex rel. Badke v.
Greendale Village Board, even though the Common Council will not take formal action at this meeting.
Notice is given that upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through
appropriate aids and services. For additional information, please contact the Franklin City Clerk’s office at (414) 425-7500.
Page 1 of 1
FORMER NORTHWESTERN MUTUAL SIGN DIMENTIONS
Mounting Surface (Face) 8’ X 40’
BRAND STANDARDS GUIDE
July 17, 2019
Brand Standards GuideBRAND STANDARDS GUIDE
PREFERRED REVERSE
SINGLE COLOR WHITE
PREFERRED
SINGLE COLOR BLUE
SINGLE COLOR BLACK
Brand Standards GuideBRAND STANDARDS GUIDE
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000
Preferred Logo
The color logo is the preferred version for reproduction.
Single Color Logo
When circumstances don’t allow for color reproduction, or for applications
such as embossing, engraving, vehicle decals, etc., the black, blue or white
versions of the logo can be used.
2
MINIMUM SIZE
1.0″
To ensure that the logo is always legible, it should never be reproduced
smaller than 1” wide.
Brand Standards GuideBRAND STANDARDS GUIDE
CLEAR SPACETAGLINE LOGO LOCKUP
The space directly surrounding the logo is the clearspace. To ensure the
visibility and impact of the Franklin logo, this clearspace must be kept free of
other competing visual elements such as type, images and other logos. The
clearspace above, below and on each side is equal to the height of the lower
case letters in the logo.
Our tagline “Celebrating Quality of Life” appears in a specific size, type, color
and locked up relationship to the logo. Always use this logo / tagline lockup
version when showing the logo with the tagline.
The tagline may be used alone as a design element. It appears in a specific
type and in a single color – bright blue from the Franklin color palette, black
or white. Leave ample clear space around the tagline to maintain readability
and impact. Only use an approved tagline art file.
Positioning on a page is either bottom left, aligned with the Franklin type in
the logomark or bottom right. The Franklin letterhead is an example of the
tagline used separately and in the correct position.
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 3
TAGLINE GRAPHIC
Typography should be aligned flush left with the
Franklin Wisconsin type in the logo, allowing the
banner icon to be set-off and emphasized on the
left. This alignment is illustrated on the corporate
letterhead as shown on page 6.
ALIGNING WITH THE LOGOMARK
Brand Standards GuideBRAND STANDARDS GUIDE
Brand Standards GuideBRAND STANDARDS GUIDE
DO NOT
Do not skew or stretch
Don’t change logo orientation
Do not place logo over an image or pattern Don’t apply any filters or textures
Do not use alternate colors
Don’t apply shadows, glow effects, or outlines
Do not fade or screen
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 4
Brand Standards GuideBRAND STANDARDS GUIDE
Typographic logo full color
Typographic logo single color
Brand Standards GuideBRAND STANDARDS GUIDE
Franklin banner icon full color
Franklin banner icon single color
LIMITED USE IDENTITY ELEMENTS
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 5
Celebrating
Quality of Life
Celebrating
Quality of Life
Celebrating
Quality of Life
In limited uses the Franklin banner icon and logotype may be split up.
This should only be used in decorative applications such as banners.
Some examples of that usage are shown below.
Brand Standards GuideBRAND STANDARDS GUIDE
GRAPHIC BANNER ELEMENTS
TYPEFACES
Roboto Sans Condensed and Merriweather Light are the Franklin brand
typestyles. Consistent use of these fonts in all communications is integral to
maintaining the brand. Both fonts are free downloads for both PC and Mac
from many different font websites and are easily found on a Google search.
Headline
ROBOTO SANS CONDENSED BOLD CAPS
Subhead
Roboto Sans Condensed Bold
Body Copy
Roboto Sans Condensed
Roboto Sans Condensed Italic
Roboto Sans Condensed Light
Roboto Sans Condensed Light Italic
Merriweather Light
Merriweather Light Italic
CMYK 100C 85M 30Y 23K
RGB 0R 46G 109B
HEX 002e6d
PANTONE 294
CMYK 62C 0M 96Y 0K
RGB 107R 190G 74B
HEX 6bbe4a
PANTONE 360
CMYK 82C 12M 0Y 0K
RGB 0R 167G 227B
HEX 00a7e1
PANTONE 2995
COLOR
CMYK 0C 26M 100Y 0K
RGB 254R 192G 15B
HEX fec00f
PANTONE 7408
Primary Palette
The colors of the primary palette are those found in the Franklin logo. These
colors should be used in all materials, publications and communications.
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 6
Distinctive banner graphics have been developed to enhance and strengthen
the Franklin brand. They are appropriate for print, digital and dimensional
applications.
Brand Standards GuideBRAND STANDARDS GUIDE
FILE TYPE USAGE
File type Description
An .EPS file is a vector-based file meaning your
logo can be enlarged or made smaller. When
increasing or decreasing the size of your logo it will
not become blurry. An.EPS file can only be opened/
edited using specific design software.
A .JPG file is a pixel-based file that cannot be
enlarged but can be made smaller. When increasing
the size of your logo it WILL cause pixelation
causing your logo to become blurry. A .JPG file will
always have a white background. It’s universal and
can be opened on any device.
A .PNG file is a pixel-based file that cannot be edited
or enlarged but can be made smaller. When
increasing the size of your logo it WILL cause
pixelation causing your logo to become blurry. A
.PNG file as a transparent/clear background. It’s
universal and can be opened on any device.
Usage
An .EPS file is used for printing
purposes such as signs, business
cards, postcards, brochures,
t-shirts, hats, etc..EPS files are set
up either in Pantone (PMS) colors
or CMYK colors.
A .JPG file is used for web and
electronic file purposes because it
has a significantly lower file size and
is in RGB color. This file type should
not be used for print.
A .PNG file is used for web and
electronic file purposes because it
has a significantly lower file size and
is in RGB color. This file type should
not be used for print.
Software
Quark, Illustrator, InDesign, Corel,
High resolution printing software
Word, PowerPoint, Excel,
Web applications
Word, PowerPoint, Excel,
Web applications
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 7
.PNG
.JPG
.EPS
Brand Standards GuideBRAND STANDARDS GUIDE
VEHICLE GRAPHICS
Pictured are vehicle decals for Franklin Public Works vehicles.
Please contact ???? for approved vehicle decal art.
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 8
Brand Standards GuideBRAND STANDARDS GUIDE
Steve Olson
Mayor
solson@franklinwi.gov
p (414) 427-7529
C (414) 651-3367
F (414) 425-6428
City of Franklin
9229 West Loomis Road
Franklin, WI 53132
franklinwi.gov
City of Franklin
Office of the City Clerk
Name Here
Company Name
1234 Main Street
City, ST , 54321
Ovid que inctustrum facia dolorat moluptatur restionse nonsequi nonsere adis audae nus mo qui verfero incim non et
omnihic te nobitiur atisti debitatur simi, que corum sit faciis audi optate sit, tem quae endit, omnis aut latenet auda dit
volupid quodi vendit, nullantur? Qui sam nonet que ellandam et est, velignia simeniant min conetus sim sandis ut esequam
sequas andus sit pernatiunt lautet et quibust quam repudignam, elit aut est ea quatquas modia il excessequunt haribust,
sitati aut aut latur aut aut dis mo illupta eaque rem quo optasin culla es nonsecu ptatemporem erio. Nam nonest, et
harunt.
Uditius et pa ducipsam voluptatur acea que comnistorum fugias rehenempore doluptas sinvelis etur, ium ut As autem
aceperepe culpa voluptaqui reius, consedisit, seque vit, comnim volest eossunt ustrum alis sam anis de sanimus, consente
omnis modiani officidus dolorum, sedicita essimperum harum senimil idebisciis dolo doluptatur, corior archil idic tem et
milis et omnis aceptis pe molorro eos expliant eos am, non re neverione ssecum utem velit rate lam facit rem. Simollabo.
Et aut doluptatusa nonse di in paritet intis alitas alicitia in corem voluptas sanimus et moluptatiume accus.
Ma et aut aces doluptatiunt et aribernat eosae dolecto moluptatem faccae doluptas inciis est es natur aut ped quis aut
ut harion con poribus nullaceaquam nonem aut haris cus aborestrum rehendendio idunti volupta sanitium as con re peris
debis seque vel eniminc itiur? Iquam rest, et ention nonsequ assitio nsenti quis aborerchit ommoluptat aliqui debitio. Nem.
Namus es ped unt antibernam es dest omnis as sequi aut quis in peliae re ercient fugias dolut occus, autatatquas sunt
ipsaero voluptatatia de
9229 West Loomis Road Franklin, WI 53132-9630 p (414) 427-7566 F (414) 427-7691 franklinwi.gov
Name Here
Company Name
1234 Main Street
City, ST , 54321
City of Franklin
9229 West Loomis Road
Franklin, WI 53132-9630
City of Franklin
9229 West Loomis Road
Franklin, WI 53132-9630
Name Here
Company Name
1234 Main Street
City, ST , 54321
BUSINESS SYSTEM
QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 9
Stationery Templates
Formats have been established for Franklin stationery. Always use approved
stationery documents. Templates are available from ?????.
City of Franklin, Wisconsin Master Logos
COLOR SPACE 4C PMS / CMYK / RGB
FILE FORMATS EPS / PNG / JPG
COLOR SPACE Black
FILE FORMATS EPS / PNG / JPG
Taglines
COLOR SPACE 1C PMS / CMYK / RGB
FILE FORMATS EPS / PNG / JPG
COLOR SPACE 3C PMS / CMYK / RGB
FILE FORMATS EPS / PNG
COLOR SPACE White
FILE FORMATS EPS / PNG
COLOR SPACE Black
FILE FORMATS EPS / PNG / JPG
COLOR SPACE White
FILE FORMATS EPS / PNG
CITY OF FRANKLIN
REPORT TO THE ECONOMIC DEVELOPMENT COMMISSION
Meeting of September 30, 2026
Minor Site Plan amendment, Solar Facility
RECOMMENDATION
Minor Site Plan Amendment, Solar: Planning Staff recommends approval of the Site Plan
Amendment, subject to the conditions in the Draft Resolution.
Project Name: Paleria Brothers LLC Solar
Property Owner: FLEX 2020, LLC
Applicant: Paleria Brothers LLC
Property Address/Tax Key Number: 9848 S 57th St, 899 0005 000
Aldermanic District: District 4
Agent: Tawni Latterell, Wolf River Electric
Zoning District: Planned Development Legacy 7
Use of Surrounding Properties: PDL 18 (east)
PDL 7 (south and west)
LI Limited Industrial (north)
Staff Planner: Marion Ecks, AICP, Principal Planner
Minor Site Plan Amendment and Utility Location:
The applicant has submitted a Minor Site Plan amendment to allow for installation of roof -
mounted photovoltaic (solar) panels. Since this facility is located in the Franklin Industrial Park,
Planned Development Legacy No. 7 requires that the location of utilities such as solar panels be
subject to approval by the Economic Development Commission (EDC).
City Development staff reviewed it and informed the applicant of this requirement.
Site Plan:
The property is located on the east side of South 57
th Street and the development consists of a
single industrial building, outdoor storage areas, and related parking. The eastern half of the
parcel is a wetland area.
The proposed solar installation consists of two groups of solar panels totaling 108 panels, all on
the building roof. Metering equipment will be mounted on the east wall of the building. There
are no ground-based improvements or additional impervious surface proposed. As a result, there
are no proposed impacts to any natural resources on the property. There will be no changes to
the building’s architecture.
2
PDL 7 allows a maximum height of 50’; the proposed panels will be a maximum of two (2) feet
from the roof and do not exceed the height requirement. The applicant states that the panels will
not be visible from the ground and will therefore not require screening. Staff rec ommends a
condition that if roof mounted mechanical equipment is visible from any public street, the owner
will be responsible for providing appropriate screening.
The location of utilities requires approval of the Economic Development Commission (EDC)
(Sec. 12.10(18)).
Staff Recommendation:
Minor Site Plan amendment:, City Development staff recommend s approval of the proposed
Site Plan Amendment application, subject to the following conditions:
• If roof mounted mechanical equipment is visible from any public street, the owner will be
responsible for providing appropriate screening.
The attached Site Plan Amendment resolution includes the conditions listed above.
ECONOMIC DEVELOPMENT COMMISSION
OF THE CITY OF FRANKLIN, WISCONSIN
[Draft 09-23-26]
RESOLUTION NO. 2026-_____
A RESOLUTION APPROVING A MINOR SITE PLAN AMENDMENT
TO ALLOW FOR INSTALLATION OF SOLAR PANELS
FOR PALERIA BROTHERS LLC
9848 S 57TH ST.
(FLEX 2020 LLC, PROPERTY OWNER)
WHEREAS, Paleria Brothers LLC , having petitioned the City of Franklin for
approval of a minor site plan amendment to allow for photovoltaic (solar) panels for Paleria
Brothers LLC, in the City of Franklin Industrial Park, property located at 9848 S 57th St.,
Franklin Industrial Park; and
WHEREAS, the Economic Development Commission having reviewed the proposed
site plan amendment and found same to be in compliance with and in furtherance of the
standards of Planned Development District No. 7.
NOW, THEREFORE, BE IT RESOLVED, by the Economic Development
Commission of the City of Franklin, Wisconsin, that the site plan amendment City file -
stamped September 14, 2026, attached hereto and incorporate herein as Exhibit A, be and the
same is approved, subject to the following conditions:
1. That the Paleria Brothers LLC site plan amendment shall be constructed pursuant to
such proposed plans within one year from the date of adoption of this Resolution, or
this Resolution and all rights and approvals granted hereunder shall be null and void,
without any further action by the Economic Development Commission.
2. The Economic Development Commission (EDC) hereby approves the location of the
photovoltaic (solar) panels as a utility fe ature in accordance with Sec. 12.10(18) of
Planned Development Legacy (PDL) 7.
3. The applicant must obtain a building permit from the Inspection Services Department
prior to the construction of the proposed solar facility.
4. The applicant must obtain approval of utilities, grading and erosion control from the
Engineering Department prior to any land disturbance activities.
5. If r oof mounted mechanical equipment is visible from any public street, the owner
will be responsible for providing appropriate screening.
Introduced at a regular meeting of the Economic Development Commission of the
City of Franklin this _______ day of ____________________, 2026.
Passed and adopted at a regular meeting of the Economic Development Commission
of the City of Franklin this _______ day of ____________________, 2026.
APPROVED:
_________________________________
Chairman
ATTEST:
__________________________________
Vice Chairman
AYES ______ NOES ______ ABSENT ______
[9/8/2026] Sent via Email & US Mail Department of City Development City of Franklin 9229 W. Loomis Road Franklin, WI, 53132 mecks@franklinwi.gov Re: Project Narrative Paleria Brothers LLC
Project Overview
The proposed project consists of the installation of two roof-mounted photovoltaic (PV) solar
energy
systems
at
the
existing
commercial
building
located
at
9848
S
57th
St,
Franklin,
WI
53132
.
Both
systems
will
be
installed
on
the
existing
roof
structure
utilizing
a
low-profile,
ballasted
racking
system
and
will
be
interconnected
with
the
building's
existing
electrical
infrastructure
at
their
respective
system
voltages.
The proposed racking system will be designed and installed to meet the applicable structural
load
requirements
of
the
existing
building.
The
low-profile
design
will
minimize
the
overall
height
and
visual
impact
of
the
solar
installation.
The
top
of
the
module
rows
will
be
approximately
two
feet
above
the
roof
surface
,
which
is
well
below
the
existing
building
parapet.
As
a
result,
the
solar
arrays
will
be
virtually
invisible
from
ground
level
.
The project will be interconnected with the We Energies electrical distribution system. All
equipment
and
installation
will
be
performed
in
accordance
with
the
approved
electrical
and
structural
plans,
applicable
Wisconsin
codes
and
standards,
We
Energies
interconnection
requirements,
and
the
manufacturer's
installation
instructions.
System 1 – 28.800 kW DC / 25.000 kW AC
System 1 will consist of 72 photovoltaic modules , each rated at 400 watts, for a total installed
DC
capacity
of
28.800
kW
DC
.
The PV modules will be installed using a low-profile, ballasted roof-mounted racking
system
.
The
racking
system
will
be
designed
to
meet
the
applicable
structural
load
requirements
and
will
be
installed
in
accordance
with
the
approved
project
structural
design
and
manufacturer's
installation
requirements.
DC power generated by the array will be connected to one 25.000 kW AC inverter . The
inverter
will
convert
the
array's
DC
output
to
AC
power
for
utilization
by
the
building
electrical
system.
System 1 will be interconnected with the building's existing 208-volt electrical system . The AC
interconnection,
overcurrent
protection,
disconnecting
means,
grounding
and
bonding,
conductor
sizing,
and
associated
electrical
equipment
will
be
installed
as
shown
on
the
approved
electrical
plans
and
in
accordance
with
applicable
code
requirements
and
We
Energies
interconnection
requirements.
System 2 – 43.200 kW DC / 36.000 kW AC
System 2 will consist of 108 photovoltaic modules , each rated at 400 watts, for a total installed
DC
capacity
of
43.200
kW
DC
.
The PV modules will be installed using a low-profile, ballasted roof-mounted racking
system
.
The
racking
system
will
be
designed
to
meet
the
applicable
structural
load
requirements
and
will
be
installed
in
accordance
with
the
approved
project
structural
design
and
manufacturer's
installation
requirements.
DC power generated by the array will be connected to one 36.000 kW AC inverter . The
inverter
will
convert
the
DC
output
of
the
PV
array
to
AC
power
for
utilization
by
the
building
electrical
system.
System 2 will be interconnected with the building's existing 480-volt electrical system . The AC
interconnection,
overcurrent
protection,
disconnecting
means,
grounding
and
bonding,
conductor
sizing,
and
associated
electrical
equipment
will
be
installed
as
indicated
on
the
approved
electrical
plans
and
in
accordance
with
applicable
code
requirements
and
We
Energies
interconnection
requirements.
Roof-Mounted Installation
Both PV arrays will be located on the existing building roof. The module layout will maintain
required
roof
access,
equipment
access,
fire-access
pathways,
setbacks,
and
other
clearances
required
by
the
applicable
building
and
fire
codes
and
the
authority
having
jurisdiction.
The ballasted, low-profile racking system will be designed to meet the structural load
requirements
of
the
existing
roof
and
will
be
installed
as
detailed
in
the
approved
project
structural
plans.
The
ballasted
system
is
intended
to
minimize
roof
penetrations
while
providing
the
required
stability
and
structural
performance
for
the
PV
arrays.
The low-profile configuration will keep the solar modules below the existing building parapet.
The
top
of
the
module
rows
will
be
approximately
two
feet
above
the
roof
surface
,
well
below
the
parapet,
making
the
solar
installation
virtually
invisible
from
the
ground
and
minimizing
its
visual
impact
on
the
surrounding
area.
PV wiring will be routed from the roof-mounted modules to the associated inverter equipment.
DC
and
AC
conductors
will
be
properly
supported,
protected,
identified,
and
routed
in
accordance
with
applicable
electrical
code
requirements.
The
systems
will
include
required
grounding
and
bonding,
overcurrent
protection,
disconnecting
means,
rapid
shutdown
provisions
where
applicable,
equipment
labeling,
and
other
required
safety
components.
Electrical Interconnection
The two PV systems will operate as separate generating systems and will connect to separate
existing
electrical
systems
within
the
facility:
● System 1: 28.800 kW DC / 25.000 kW AC, interconnected at 208 volts through one
25.000
kW
AC
inverter.
● System 2: 43.200 kW DC / 36.000 kW AC, interconnected at 480 volts through one
36.000
kW
AC
inverter.
The combined project capacity is 72.000 kW DC and 61.000 kW AC .
The PV systems are intended to provide on-site electrical generation and offset facility electrical
consumption.
The
systems
will
be
interconnected
with
the
existing
electrical
service
in
accordance
with
the
approved
plans
and
the
requirements
of
We
Energies
.
Utility
interconnection
equipment,
metering,
protection,
and
associated
requirements
will
be
provided
and
installed
as
required
by
the
utility
and
approved
project
design.
Completion and Commissioning
Upon completion of installation, all PV modules, racking, inverters, wiring, disconnects, and
associated
electrical
equipment
will
be
inspected
and
tested.
The
systems
will
be
commissioned
in
accordance
with
the
equipment
manufacturers'
requirements
and
the
approved
project
plans.
The completed installation will be subject to the required inspections and utility approval prior to
final
operation.
The
installation
will
comply
with
applicable
Wisconsin
building
and
electrical
requirements,
approved
structural
and
electrical
plans,
manufacturer
installation
requirements,
and
We
Energies
interconnection
requirements.
Sincerely,
Cody M. Rossmann Senior Project Manager Wolf River Electric cody@wolfriverelectric.com Direct: (763) 297-3597
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 0.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
COVER SHEET
PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM9848 S 57TH ST, FRANKLIN, WI 53132, USA SYSTEM SIZE: 43.200 kW DC36.000 kW ACMODULE TYPE & AMOUNT:(108) WAAREE ARKA SERIES WSMDI-400 [400W]MODULE DIMENSIONS:(L/W/H) 75.75"/40.86"/1.37" INVERTER:(1) CPS SCA36KTL-DO/US-480INTERCONNECTION METHOD: LINE SIDE TAP
SCALE: NTS2VICINITY MAPPV 0.0SCALE: NTS1SATELLITE VIEWPV 0.0
42.865667, -87.98694042.865667, -87.986940
108 MODULES - ROOF MOUNTED - 43.200 kW DC, 36.000 kW ACGENERAL ELECTRIC NOTES:1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC2017.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTEDPRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAMERACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHENTHEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, ITSHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47 AND 250.50 THROUGH 60AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTINGBUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM ISINACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED ATTHE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGERTHAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDEFOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNEDAND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THEROOF SURFACE.10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSEDTO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.11.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDINGTO NEC 690.35(F).12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONSHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOFMOUNTED TRANSITION BOXES AND SWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NECARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION IN ACCORDANCE WITH NEC 690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATIONWITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUITRUNS AS REQUIRED PER NEC.
AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF FRANKLINZONING: CITY OF FRANKLINUTILITY: WE ENERGIESUTILITY METER NUMBER: 159 016 581
GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C
SHEET INDEX:PV 0.0:COVER SHEETPV 0.1:PLOT PLANPV 1.0:SITE PLANPV 1.1:ATTACHMENTPV 1.2:STRING LAYOUTPV 1.3:EQUIPMENT ELEVATIONS 1.0: MOUNT DETAILSS 1.1: MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:WIRE CALCULATIONE 1.3:WARNING LABELSE 1.4:PLACARDD 1.1+:EQUIPMENT SPEC SHEETGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa.2017 NATIONAL ELECTRICAL CODEb.2024 WISCONSIN UNIFORM DWELLING CODEc.2015 INTERNATIONAL BUILDING CODEd.2015 INTERNATIONAL MECHANICAL CODEe.2015 INTERNATIONAL FUEL GAS CODEf.2015 INTERNATIONAL EXISTING BUILDING CODEg.2015 INTERNATIONAL ENERGY CONSERVATION CODEh.ANY OTHER LOCAL AMENDMENTS
339'-10"
392'-5"
326'-76"
468'-8"
53'-6"
50'-9"191'-7"74'-5"
N
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 0.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
PLOT PLAN SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.1
PARCEL: 8990005000PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT: 3.21 ACRES
PROPERTY LINE
ROOF ACCESS POINT
DRIVEWAY
ROOF #1(108) WAAREE ARKA SERIES WSMDI-400[400W]SLOPE: 15°AZIM.: 180°
MEXISTING INTERIOR MAIN SERVICE PANELEXISTING CL20 METER #159 016 581.
NEW AC DISCONNECTNEW CPS SCA36KTL-DO/US-480 INVERTER
FENCEPROPERTY LINE
PROPERTY LINEPROPERTY LINENOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.
ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS.
TREES
CT
9848 S 57TH STFRONT OF BUILDING
DRIVEWAY
EXISTING CT CABINET
acI ACEXISTING TRANSFORMER
FENCE
MAIN BUILDINGTNEW UTILITY AC DISCONNECT
2' MAX SPACING
REVISION DATE: OCT, 16, 2025
N
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
SITE PLAN SCALE: 1/8" = 1'-0"1SITE PLANPV 1.0
ROOF SECTIONS
SYSTEM LEGENDACNEW UTILITY AC DISCONNECTEXISTING EXTERIOR CL20 METER#159 016 581.
ROOF FIRE SUPPRESSION SPRINKLERSYSTEM:NOTOTAL ROOF AREA:18271.99ft2 TOTAL MODULE AREA:2321.36ft2 TOTAL AREA COVERED:12.70%
= ROOF OBSTRUCTIONS= EXTERIOR RUN= CONDUIT ROOF TOP JUNCTION BOX
ROOF ACCESS POINT
acNEW AC DISCONNECTCTEXISTING EXTERIOR CT CABINET
MODULE - 108SLOPE - 15°AZIMUTH - 180°MATERIAL - TPOROOF #01
108 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULES
ROOF #01
48" FIRE SETBACK
9848 S 57TH STFRONT OF BUILDING
INEW (1) CPS SCA36KTL-DO/US-480 3 PHASESTRING INVERTER
NOTE:ROOFTOP RUN CONDUIT SHALL BE MINIMUM7/8 INCHES FROM ROOF SURFACE.
MEXISTING INTERIOR MAIN SERVICE PANEL
M
48" FIRE SETBACK
48" FIRE SETBACK
48" FIRE SETBACK
48" FIRE SETBACKCTAC
ac
NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS.
I
2' MAX SPACING
SYSTEM #1 AT 208V(72) WAAREE ARKA SERIES WSMDI-400 [400W]
SYSTEM #2 AT 480V(108) WAAREE ARKA SERIES WSMDI-400 [400W]
2' MAX SPACING 48" FIRE SETBACK
REVISION DATE: OCT, 16, 2025
NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ATTACHMENTSCALE: 1/8" = 1'-0"1 ATTACHMENTPV 1.1
SYSTEM LEGENDUNIRAC RM10 EVO NORTHROW BAY (26 Nos)UNIRAC RM10 EVO FIELDBAY (158 Nos)TOTAL NO. OF BALLAST BLOCK (387 NOS)= RM10 ATTACHMENTKIT(22 Nos)= MID SUPPORT (87 NOS)
REVISION DATE: OCT, 16, 2025
1.11.12.12.13.1
3.14.1
4.16.19.19.18.18.17.17.16.15.15.1NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
STRING LAYOUT SCALE: 1/8" = 1'-0"1STRING LAYOUTPV 1.2
SYSTEM LEGEND1.1INVERTER #112 MODULES1.21.312 MODULES12 MODULES1.412 MODULES1.51.612 MODULES12 MODULES1.712 MODULES1.81.912 MODULES12 MODULES
REVISION DATE: OCT, 16, 2025
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
EQUIPMENTELEVATIONUNDERGROUNDSERVICESCALE: NTS1EQUIPMENT ELEVATIONPV 1.3
FROM PV ARRAYFROM (E)CT CABINETWITH CL20METER<10'(E) CT CABINETWITH CL20METER#14 147 162(E) MAINSERVICE PANEL
INTERIOR WALLEXTERIOR WALL
4'(N) UTILITY AC DISCONNECT
(N) INVERTER(E) CT CABINETWITH CL20METER#159 016 581(N) AC DISCONNECT
ON ROOF
UNDERGROUNDSERVICETO (E) MAIN SERVICE PANEL.
14"1' 1'-12"12"16"1'-28"53 13 4RM10 EVO NORTHROW BAYTOP ROOF SURFACE
PV MODULERM10 EVO FIELD BAYEVO MOD CLAMP KIT
1ATTACHMENT DETAILS 1.0SCALE: NTSSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
S 1.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNT DETAIL
GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
S1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNT DEATILS
(NEW) CPS SCA36KTL-DO/US-480INVERTER 480 VAC, 43.5A, 97.4% CECWEIGHTED EFFICIENCYUL 1741 LISTEDDC
G1
L1L1L2L2L1L1L2L2L1L1L2L2L1L1L2L22 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.112 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.212 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.312 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.412 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.512 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.6(NEW) UTILITY ACDISCONNECT SWITCH,SQUARE D VH362NRB60A,FUSED, 277/480V, 3PHASE, 4 WIRE,NEMA3RSURGE PROTECTIVE DEVICEREFERENCE POINT OFAPPLICABILITY (RPA)
108 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULES
GN
L2L1MTO UTILITY GRIDL3
EXISTING 480V/225ABUSBAR RATING,MAIN SERVICEPANEL, 3P,4W
N
EXISTING GROUNDINGELECTRODE SYSTEM
EPOINT OFINTERCONNECTIONLINE SIDE TAP225A
12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.712 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.8G
L1L1L2L2L1L1L2L2L1L1L2L2
(NEW) JUNCTION BOX#2600 V, NEMA 4UL LISTED
L1L1L2L2(NEW) JUNCTION BOX#1600 V, NEMA 4UL LISTED
L1L1L2L2G 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.91A2A
(NEW) JUNCTION BOX#3600 V, NEMA 4UL LISTED
3
E 60A FUSESGVISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE<10'
NEW GROUNDINGELECTRODE SYSTEMG
(NEW) AC DISCONNECTSWITCH,SQUARE D VHU362RB 60A,NON-FUSED,277/480V, 3 PHASE, 4WIRE, NEMA3R34
EXISTING 400A CT CABINET3-PHASE, 4-W, 600VCAT. NO WECT4-4L13ENCLOSURE TYPE 1/3REXISTING 20A CL20METER 3-PHASE,4-W, 480V
R FUSESSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
ELECTRICALDIAGRAM
DC System Size (Watts)AC System Size (Watts)Total Module CountPhotovoltaic System4320036000108NOTE: UTILITY AC DISCONNECT TO BEINSTALLED WITHIN 10FT FROM UTILITY METER.Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)DescriptionInverter Output (PV Wire)EGC (Bare Copper Ground)Inverter Output (THWN-2)EGC (THWN-2)Inverter Output (THWN)EGC (THWN)Wire Gauge# of Conductors/ColorConduit TypeConduit SizeTag #8 AWG (AL)8(4L1,4L2,4L3), 2(L1,L2,L3)1 BARE1 (GRN)4(L1, L2, L3, N)1 (GRN)Free AirFree AirPVCSCH 80 PVCN/AN/A1"1" 1, 1A1, 1A2, 2A2, 2A3312 AWG6 AWGSCH 80 PVC12 AWG12 AWG3 AWG (AL)1-1/4"8(4L1,4L2,4L3), 2(L1,L2,L3)PVC Inverter Output (THWN)SCH 80 PVC44(L1, L2, L3, N)
NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C [480V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA36KTL-DO/US-480MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER61.2 KWNOMINAL AC VOLTAGE480 VOLTSMAX. AC CURRENT43.5 AMPSAC POWER36000 W3 AWG (AL)1-1/4"1-1/4"
REVISION DATE: SEP, 27, 2025REVISION DATE: SEP, 27, 2025
REVISION DATE: OCT, 16, 2025REVISION DATE: NOV, 12, 2025
NOTE:LOAD-SIDE TAPS ARE ONLY ALLOWABLE INSIDETRANSOCKET IF THEY ARE LANDED ON THE TRANSOCKET’SLOAD SIDE BUS; SPLICING ONTO THE EXISTING SERVICEENTRANCE CONDUCTORS IS NOT ACCEPTABLE FOR THISPURPOSE.REVISION DATE: NOV, 12, 2025
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
WIRECALCS
Rooftop conductor ampacities designed in compliance with art. 690.8,Tables 310.15(B)(16), 310.15(B)(2)(a). Location specific temperatureobtained from ASHRAE 2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-24°C32°C CONDUIT HEIGHT7/8" CONDUCTOR TEMPERATURE RATE (ON ROOF)90°C·Designed according to and all code citations are relevant to the 2017 National Electrical Code.·Tag 2-Use 96% temperature derate for conditions of use (On roof)·Tag 3 - Use 96% temperature derate for conditions of use (adjusted ambient)·System grounding & bonding designed in compliance with 690.47(C)3 and 250.64(E)·Equipment shall be listed, tested, and marked to withstand the available short circuit currentELECTRICAL NOTES
Conductor Calculations
NUMBER OF CURRENTCARRYING CONDUCTORS INCONDUIT4-67-910-20PERCENT OF VALUES.80.70.50
CONDUCTOR TEMPERATURE RATE (OFF ROOF)75°CTEMP 0.5°54°CTHIS PANEL IS FED BY MULTIPLE SOURCES (UTILITYAND SOLAR)AC OUTPUT CURRENT ACCORDING TO ART. 690.8(B)(1)NOMINAL AC VOLTAGE480V43.5A
OCPD Calculations[480V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA36KTL-DO/US-480MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER61.2 KWNOMINAL AC VOLTAGE480 VOLTSMAX. AC CURRENT43.5 AMPSAC POWER36000 W
Breakers sized according to continuous duty output current.Inverter Output Current X (1.25[art. 690.8(A)]) X (139 Max AC current inverter)Inverter #1 = Output Current w/ continuous duty = 43.5A <= 60A Breakersystem output current w/ continuous duty = 54.38 <= 60A (System OCPD)Wire gauge calculated from code art. 310.15(B)(16) with ambient temperature calculations from art. 310.15(B)(2)(a).For "On Roof" conductors we use the 90°C column ampacity, the relevant ambient temperature adjustment, and racewayfill adjustments from 310.15(B)(16). Conduit shall be installed at least 7/8" above the roof surface.For "Off Roof" conductors we use the 75°C column ampacity, or the 75°C column ampacity with the relevant ambienttemperature and raceway fill adjustments, whichever is less.The rating of the conductor after adjustments MUST begreater than, or equal to, the continuous duty output current.Calculation Example - Wire Rating x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous DutyOutput Current(Tag 2 On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.7 (8 Conductors) = 20.16A > 14.15A (Tag 2A On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 1.0 (2 Conductors) = 28.8A > 14.15A (Tag 3 & 4 Off Roof):3 gauge AL wire rated for 75A , 75A x 0.94 x 0.8 = 56.4A > 54.38A (System Output Current)
PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
WARNINGLABELS
LABEL LOCATION: RSD INITIATION DEVICE, UTILITY AC DISCONNECTPER CODE: NEC 690.56(C)(2)
ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, UTILITY ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)
LABEL LOCATION: UTILITY AC DISCONNECTPER CODE: NEC 690.13(B)
LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)
!
LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: UTILITY AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)
DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)!
PHOTOVOLTAIC POWER SOURCEPHOTOVOLTAIC SYSTEM UTILITY AC DISCONNECTRATED AC OUTPUT CURRENT: 43.50 A NOMINAL OPERATING AC VOLTAGE: 480 V
TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMPHOTOVOLTAIC UTILITYAC DISCONNECT
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.4
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
PLACARDServiced by Wolf River ElectricContact: (763) 229-6662
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATED AS SHOWNCAUTION ! MULTIPLE SOURCES OF POWERN9848 S 57TH STMAIN SERVICE PANEL (480V)CL 20 METER (480V)
UTILITY AC DISCONNECT (480V)INVERTER (480V)CT CABINET (480V)AC DISCONNECT (480V)
INVERTER (208V)AC DISCONNECT (208V)MAIN SERVICE PANEL(208V)CL 20 METER(208V)
UTILITY AC DISCONNECT (208V)CTCABINET(208V)FUSEDDISCONNECT(208V)
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MODULE SPECSHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
INVERTER SPECSHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
CERTIFICATE OFCOMPLIANCE
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.4
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
SPD SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.5
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNTING DETAIL SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.6
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ACD SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.7
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ACD SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 0.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
COVER SHEET
PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM9848 S 57TH ST, FRANKLIN, WI 53132, USASHEET INDEX:SYSTEM SIZE: 28.800 kW DC25.000 kW ACMODULE TYPE & AMOUNT:(72) WAAREE ARKA SERIES WSMDI-400 [400W]MODULE DIMENSIONS:(L/W/H) 75.75"/40.86"/1.37" INVERTER:(1) CPS SCA25KTL-DO/US-208INTERCONNECTION METHOD: LOAD SIDE CONNECTION
SCALE: NTS2VICINITY MAPPV 0.0SCALE: NTS1SATELLITE VIEWPV 0.0
42.865667, -87.98694042.865667, -87.986940
PV 0.0:COVER SHEETPV 0.1:PLOT PLANPV 1.0:SITE PLANPV 1.1:ATTACHMENTPV 1.2:STRING LAYOUTPV 1.3:EQUIPMENT ELEVATIONS 1.0: MOUNT DETAILSS 1.1: MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:WIRE CALCULATIONE 1.3:WARNING LABELSE 1.4:PLACARDD 1.1+:EQUIPMENT SPEC SHEET
72 MODULES - ROOF MOUNTED - 28.800 kW DC, 25.000 kW ACGENERAL ELECTRIC NOTES:1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC2017.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTEDPRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAMERACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHENTHEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, ITSHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47 AND 250.50 THROUGH 60AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTINGBUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM ISINACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED ATTHE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGERTHAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDEFOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNEDAND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THEROOF SURFACE.10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSEDTO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.11.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDINGTO NEC 690.35(F).12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONSHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOFMOUNTED TRANSITION BOXES AND SWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NECARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION IN ACCORDANCE WITH NEC 690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATIONWITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUITRUNS AS REQUIRED PER NEC.
AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF FRANKLINZONING: CITY OF FRANKLINUTILITY: WE ENERGIESUTILITY METER NUMBER: 14 147 162
GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = CGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa.2017 NATIONAL ELECTRICAL CODEb.2024 WISCONSIN UNIFORM DWELLING CODEc.2015 INTERNATIONAL BUILDING CODEd.2015 INTERNATIONAL MECHANICAL CODEe.2015 INTERNATIONAL FUEL GAS CODEf.2015 INTERNATIONAL EXISTING BUILDING CODEg.2015 INTERNATIONAL ENERGY CONSERVATION CODEh.ANY OTHER LOCAL AMENDMENTS
339'-10"
392'-5"
326'-76"
468'-8"
53'-6"
50'-9"191'-7"136'-7"
N
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 0.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
PLOT PLAN SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.1
PARCEL: 8990005000PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT: 3.21 ACRES
PROPERTY LINE
ROOF ACCESS POINT
DRIVEWAY
ROOF #1(72) WAAREE ARKA SERIES WSMDI-400 [400W]SLOPE: 15°AZIM.: 180°
MEXISTING INTERIOR MAIN SERVICE PANELEXISTING CL20 METER #14 147 162.
NEW AC DISCONNECTNEW CPS SCA25KTL-DO/US-208 INVERTER
EXISTING FUSED DISCONNECT
FENCEPROPERTY LINE
PROPERTY LINEPROPERTY LINENOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.
ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS.
TREES
CT
9848 S 57TH STFRONT OF BUILDING
DRIVEWAY
EXISTING CT CABINETacIACEXISTING TRANSFORMER
FENCE
MAIN BUILDINGTNEW UTILITY AC DISCONNECT
FD
2' MAX SPACING
REVISION DATE: OCT, 16, 2025
N
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
SITE PLAN SCALE: 1/8" = 1'-0"1SITE PLANPV 1.0
ROOF SECTIONS
SYSTEM LEGEND
ACNEW UTILITY AC DISCONNECT
EXISTING EXTERIOR CL20 METER#14 147 162.
ROOF FIRE SUPPRESSION SPRINKLERSYSTEM:NOTOTAL ROOF AREA:18271.99ft2 TOTAL MODULE AREA:1547.57ft2 TOTAL AREA COVERED:8.47%
= ROOF OBSTRUCTIONS= EXTERIOR RUN= CONDUIT ROOF TOP JUNCTION BOX
ROOF ACCESS POINT
CTEXISTING EXTERIOR CT CABINET
MODULE - 72SLOPE - 15°AZIMUTH - 180°MATERIAL - TPOROOF #01
72 NEW WAAREE ARKA SERIES WSMDI-400[400W] MODULES
ROOF #01
48" FIRE SETBACK
9848 S 57TH STFRONT OF BUILDING
INEW (1) CPS SCA25KTL-DO/US-208 3 PHASESTRING INVERTER
NOTE:ROOFTOP RUN CONDUIT SHALL BE MINIMUM7/8 INCHES FROM ROOF SURFACE.
MEXISTING INTERIOR MAIN SERVICE PANELFDEXISTING FUSED DISCONNECTacNEW AC DISCONNECT
M
48" FIRE SETBACK
48" FIRE SETBACK
48" FIRE SETBACK
48" FIRE SETBACK
CTFDIac
NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS.
AC
2' MAX SPACING
SYSTEM #2 AT 480V(108) WAAREE ARKA SERIES WSMDI-400 [400W]
SYSTEM #1 AT 208V(72) WAAREE ARKA SERIES WSMDI-400 [400W]
2' MAX SPACING
REVISION DATE: OCT, 16, 2025
NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ATTACHMENTSCALE: 1/8" = 1'-0"1 ATTACHMENTPV 1.1
SYSTEM LEGENDUNIRAC RM10 EVO NORTHROW BAY (30 Nos)UNIRAC RM10 EVO FIELDBAY (106 Nos)TOTAL NO. OF BALLAST BLOCK (264 NOS)= RM10 ATTACHMENTKIT(15 Nos)= MID SUPPORT (53 NOS)
REVISION DATE: OCT, 16, 2025
1.11.11.21.2
1.3 1.31.41.41.51.51.61.6
NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
STRING LAYOUT SCALE: 1/8" = 1'-0"1STRING LAYOUTPV 1.2
SYSTEM LEGEND1.1INVERTER #112 MODULES1.21.312 MODULES12 MODULES1.412 MODULES1.51.612 MODULES12 MODULES
REVISION DATE: OCT, 16, 2025
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
PV 1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
EQUIPMENTELEVATIONUNDERGROUNDSERVICESCALE: NTS1EQUIPMENT ELEVATIONPV 1.3
FROM PV ARRAYFROM (E)FUSEDDISCONNECT<10'(E) CT CABINETWITH CL20METER#14 147 162(E) MAINSERVICE PANEL
INTERIOR WALLEXTERIOR WALL
4'(N) UTILITY AC DISCONNECT
(N) INVERTER(E) CT CABINETWITH CL20METER#159 016 581(N) AC DISCONNECT
ON ROOF
UNDERGROUNDSERVICETO (E) MAIN SERVICE PANEL.(E) FUSED DISCONNECT
14"1' 1'-12"12"16"1'-28"53 13 4RM10 EVO NORTHROW BAYTOP ROOF SURFACE
PV MODULERM10 EVO FIELD BAYEVO MOD CLAMP KIT
1ATTACHMENT DETAILS 1.0SCALE: NTSSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
S 1.0
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNT DETAIL
GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
S 1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNT DEATILS
(NEW) CPS SCA25KTL-DO/US-208INVERTER 208 VAC, 69.5A, 96.5% CECWEIGHTED EFFICIENCYUL 1741 LISTEDDC
G1
L1L1L2L2L1L1L2L2L1L1L2L2L1L1L2L22 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.112 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.212 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.312 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.412 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.512 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.672 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULESGL1L1L2L2(NEW) JUNCTION BOX#2600 V, NEMA 4UL LISTEDL1L1L2L2(NEW) JUNCTION BOX#1600 V, NEMA 4UL LISTED1A2A(NEW) UTILITY ACDISCONNECT SWITCH,SQUARE D D323NRB100A,FUSED, 120/208V,3 PHASE, 4 WIRE,NEMA3RSURGE PROTECTIVE DEVICEREFERENCE POINT OFAPPLICABILITY (RPA)GN
L2L1MTO UTILITY GRIDL3
EXISTING 208V/225ABUSBAR RATING,MAIN SERVICEPANEL, 3P,4W
N
EXISTINGGROUNDINGELECTRODESYSTEM
E POINT OFINTERCONNECTIONLOAD SIDE CONNECTION
225A
3
E 90A FUSESGVISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE<10'
G
(NEW) AC DISCONNECTSWITCH,SQUARE D DU323100A,NON-FUSED,120/208V, 3 PHASE, 4WIRE, NEMA3R33
EXISTING 400AFUSEDDISCONNECTCAT. NO PT325CLASS T FUSIBLEPULL OUT SWITCH
EXISTING 400A CT CABINET3-PHASE, 4-W, 208VCAT. NO WECT-P425NTYPT 3R ENCLOSUREEXISTING 20A CL20METER 3-PHASE,4-W, 208V
R FUSES
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
ELECTRICALDIAGRAM
DC System Size (Watts)AC System Size (Watts)Total Module CountPhotovoltaic System288002500072NOTE: UTILITY AC DISCONNECT TO BE INSTALLEDWITHIN 10FT FROM UTILITY METER.Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)DescriptionInverter Output (PV Wire)EGC (Bare Copper Ground)Inverter Output (THWN-2)EGC (THWN-2)Inverter Output (THWN)EGC (THWN)Wire Gauge# of Conductors/ColorConduit TypeConduit SizeTag #6 AWG (AL)8(4L1,4L2,4L3), 4(2L1,2L2,2L3)1 BARE1 (GRN)4(L1, L2, L3, N)1 (GRN)Free AirFree AirPVCSCH 80 PVCN/AN/A1"1" 1, 1A1, 1A2, 2A2, 2A3312 AWG6 AWGSCH 80 PVC12 AWG12 AWG1/0 AWG (AL)2" 8(4L1,4L2,4L3), 4(2L1,2L2,2L3)PVC NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C [208V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA25KTL-DO/US-208MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER45 KWNOMINAL AC VOLTAGE208 VOLTSMAX. AC CURRENT69.5 AMPSAC POWER25000 W2"
REVISION DATE: SEP, 27, 2025REVISION DATE: SEP, 27, 2025
REVISION DATE:SEP, 27, 2025REVISION DATE: OCT, 16, 2025REVISION DATE: NOV, 12, 2025
NOTE:LOAD-SIDE TAPS ARE ONLY ALLOWABLE INSIDE TRANSOCKET IFTHEY ARE LANDED ON THE TRANSOCKET’S LOAD SIDE BUS; SPLICINGONTO THE EXISTING SERVICE ENTRANCE CONDUCTORS IS NOTACCEPTABLE FOR THIS PURPOSE.REVISION DATE: NOV, 12, 2025
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
WIRECALCS
Rooftop conductor ampacities designed in compliance with art. 690.8,Tables 310.15(B)(16), 310.15(B)(2)(a). Location specific temperatureobtained from ASHRAE 2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-24°C32°C CONDUIT HEIGHT7/8" CONDUCTOR TEMPERATURE RATE (ON ROOF)90°C·Designed according to and all code citations are relevant to the 2017 National Electrical Code.·Tag 2-Use 96% temperature derate for conditions of use (On roof)·Tag 3 - Use 96% temperature derate for conditions of use (adjusted ambient)·System grounding & bonding designed in compliance with 690.47(C)3 and 250.64(E)·Equipment shall be listed, tested, and marked to withstand the available short circuit currentELECTRICAL NOTES
Conductor Calculations
NUMBER OF CURRENTCARRYING CONDUCTORS INCONDUIT4-67-910-20PERCENT OF VALUES.80.70.50
CONDUCTOR TEMPERATURE RATE (OFF ROOF)75°CTEMP 0.5°54°CTHIS PANEL IS FED BY MULTIPLE SOURCES (UTILITYAND SOLAR)AC OUTPUT CURRENT ACCORDING TO ART. 690.8(B)(1)NOMINAL AC VOLTAGE208V69.5A
OCPD Calculations[208V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA25KTL-DO/US-208MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER45 KWNOMINAL AC VOLTAGE208 VOLTSMAX. AC CURRENT69.5 AMPSAC POWER25000 W
Breakers sized according to continuous duty output current.Inverter Output Current X (1.25[art. 690.8(A)]) X (139 Max AC current inverter)Inverter #1 = Output Current w/ continuous duty = 69.5A <= 90A Breakersystem output current w/ continuous duty = 86.88 <= 90A (System OCPD)Wire gauge calculated from code art. 310.15(B)(16) with ambient temperature calculations from art. 310.15(B)(2)(a).For "On Roof" conductors we use the 90°C column ampacity, the relevant ambient temperature adjustment, and racewayfill adjustments from 310.15(B)(16). Conduit shall be installed at least 7/8" above the roof surface.For "Off Roof" conductors we use the 75°C column ampacity, or the 75°C column ampacity with the relevant ambienttemperature and raceway fill adjustments, whichever is less.The rating of the conductor after adjustments MUST begreater than, or equal to, the continuous duty output current.Calculation Example - Wire Rating x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous DutyOutput Current(Tag 2 On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.7 (8 Conductors) = 20.16A > 14.15A (Tag 2A On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.8 (4 Conductors) = 23.04A > 14.15A (Tag 3 Off Roof):1/0 gauge AL wire rated for 120A , 120A x 0.94 x 0.8 = 90.24A > 86.88A (System Output Current)
PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
WARNINGLABELS
LABEL LOCATION: RSD INITIATION DEVICE, UTILITY AC DISCONNECTPER CODE: NEC 690.56(C)(2)
ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, UTILITY ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)
LABEL LOCATION: UTILITY AC DISCONNECTPER CODE: NEC 690.13(B)
LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)
!
LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: UTILITY AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)
DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)!
PHOTOVOLTAIC POWER SOURCEPHOTOVOLTAIC SYSTEM UTILITY AC DISCONNECTRATED AC OUTPUT CURRENT: 69.50 A NOMINAL OPERATING AC VOLTAGE: 208 V
TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMPHOTOVOLTAIC UTILITYAC DISCONNECT
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
E 1.4
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
PLACARDServiced by Wolf River ElectricContact: (763) 229-6662
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATED AS SHOWNCAUTION ! MULTIPLE SOURCES OF POWERN9848 S 57TH STMAIN SERVICE PANEL (480V)CL 20 METER (480V)
UTILITY AC DISCONNECT (480V)INVERTER (480V)CT CABINET (480V)AC DISCONNECT (480V)
INVERTER (208V)AC DISCONNECT (208V)MAIN SERVICE PANEL(208V)CL 20 METER(208V)
UTILITY AC DISCONNECT (208V)CTCABINET(208V)FUSEDDISCONNECT(208V)
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.1
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MODULE SPECSHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.2
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
INVERTER SPECSHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.3
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
CERTIFICATE OFCOMPLIANCE
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.4
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
SPD SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.5
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
MOUNTING DETAIL SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.6
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ACD SPEC SHEET
Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL
ARCH D24" X 36"
Signature with Seal
Project Name &Address
D1.7
DESIGNED BY:TRIVENT CAD SOLUTION
RevDateDescriptionREVISIONS
WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES
07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025
ACD SPEC SHEET
Requested By:
John Regetz
Email:
jregetz@franklinwi.gov
Work Phone:
(414) 427-7566
Salesperson:
Dylan Braun
NO.
Product Summary
QTY
UNIT PRICE
UNIT PRICE
AMOUNT
1
Metal Letters for Monument
1
$11,636.60
$11,636.60
$11,636.60
1.1
Dimensional Letters - Dimensional letters
Text:
Metal Letters to Be Stud Mounted on
Existing Monument -
120
SF
Copy :
Logo
Welcome To
Franklin
Material:
1/4
" thick painted brushed
aluminum
Colors:
Pantone
294
c,
360
c,
2995
c,
7408
c
** for payment with credit card there
will be
3%
fee applied to the final
balance **
1.2
Graphic Design Fee - Artwork
2
Install
1
$885.00
$885.00
$885.00
2.1
Installation - 2 person crew
Subtotal:
$12,521.60
Taxes:
$738.77
Grand Total:
$13,260.37
Deposit Required:
$6,630.19
Bill To:
City of Franklin
9229 W Loomis Road
Franklin, WI 53132
US
Installed:
City of Franklin
corner of 27th & Drexel
Franklin, WI 53555
US
DESCRIPTION:
Option 2 - Monument Refresh
ESTIMATE
EST-17517
PO Number:
Payment Terms:
Cash Customer
First Impressions, Great Results
www.innovative-signs.com
21700 Doral Rd
Waukesha, WI 53186
(262) 432-1330
Created Date:
9/24/2026
Please Note: This estimate is a preliminary approximation and is not a
guaranteed final price. It is based on information provided by the client
regarding project requirements. Due to the volatility of the materials market,
prices are subject to change. The actual cost may be adjusted once all project
details are finalized and negotiations are complete. Any changes in cost will be
communicated to the client prior to implementation.
Generated On:
9/25/2026 9:28 AM
Page
1
of
2
30.6 in
59.8 in
14.4 in
119.98 sqft
Date
9/24/2026
Order #
EST - 17517
Customer
City Of Franklin
Ashlee K.
Paint - Finish
Specifications
Designer
Dylan B.
Project Manager
Pantone 294c
Pantone 360c
Pantone 2995c
Pantone 7408c
www.Innovative-Signs.com
- 1/4” Painted metal logo
- Stud mounted
72.26 in
40.8 in
239.1 in
COMPANY NAME: City of Franklin
DOLLAR AMOUNT: Multiple Options
ESTIMATE #: 19120
SITE ADDRESS: W Drexel Ave & S 27th St, Franklin, WI 53132
September 24, 2026 Page 1 of 2
CONTRACT
JOB DESCRIPTION:
Letters for Existing Monument
Option #1: ‘Welcome to Franklin, Celebrating Quality of Life, Logo’
Fabricate and install (1) set nonlit 1/4'' thick aluminum FCO letters and logo
''WELCOME TO FRANKLIN CELEBRATING QUALITY OF LIFE + LOGO''
Overall size approximately 62''H x 200''W
Will mount to existing Stone Monument Wall
Includes removal of existing nonlit Northwestern Mutual letters
$10,740.00
Option #2: ‘Welcome to Franklin, Logo’
Fabricate and install (1) set nonlit 1/4'' thick aluminum FCO letters and logo
''WELCOME TO FRANKLIN + LOGO''
Overall size approximately 56''H x 181''W
Will mount to existing Stone Monument Wall
Includes removal of existing nonlit Northwestern Mutual letters
$8,025.00
Site Survey
Confirming access, mounting methods, proposed sizes, and colors.
$375.00
Permit Procurement
Standard permit application paperwork and submittal. If the municipality requires a board meeting for review,
attendance is billed at $75/hr.
City permit fees billed at cost on final invoice.
$375.00
This contract will expire in 30 days from the date listed below if not executed before.
Payment terms: Down payment of 50%, Balance due Net 15 Days from installation
Date.
Permits are not included in this contract and will be added to final invoice as they apply to
actual cost & time to procure.
Any alterations or deviation from above specifications involving extra cost will become an
extra charge over and above the quoted price.
I the customer understand and agree that electrical feed and final hook up may include
extra charges and is my complete responsibility.
Included in this proposal are the costs agreed to by the parties, these costs have been calculated
assuming that no unusual or unstable subsurface condition exists or are encountered during construction. If
unusual or unstable soil conditions exist or are encountered, the cost of additional foundation work and material
will be treated as an extra cost to be added to the above total. Customer ag rees to pay for extra foundation work
at the following rates: Materials at cost plus 15%; labor at the rate of $25. 00 per man per hour; soils engineering
expert at the rate charged by the soils engineering expert. Customer agrees to be solely responsible for all costs
related to unusual or unstable soils conditions even where those conditions have been previously discl osed to
Sign Effectz. If the parties have agreed to incorporate or use an existing foundation, Customer agrees any costs
incurred as a result of the inadequacy or failure of the existing foundation will be an extra which customer
agrees to pay pursuant to the above rate schedule. Payment of all extra costs incurred under this parag raph is
COMPANY NAME: City of Franklin
DOLLAR AMOUNT: Multiple Options
ESTIMATE #: 19120
SITE ADDRESS: W Drexel Ave & S 27th St, Franklin, WI 53132
September 24, 2026 Page 2 of 2
CONTRACT
due at the time the extra work billed.
Customer shall be solely responsible for all electric service, phone lines and service hook ups of
electrical and phone. Payment of the contract price in full is due on delivery regardless of the status of the
phone and electric utility service at the sit e.
Sign Effectz retains ownership of all sign materials until final payment is made. In the event the
Customer does not make all payments required under this contract, at the times required, Customer agrees and
hereby gives Sign Effectz permission to enter up on Customer’s property to remove the sign at a time convenient
to Sign Effectz Inc., and agrees that the deposit shall constitute liquidated damages to Sign Effectz, because the
work is custom work, and the salvage value of the sign is minimal. C ustomer fu rther agrees that any damage to
the site incidental to the removal shall be borne by Customer.
Any terms in this contract / proposal which are inconsistent with the terms of a contract which this
contact / proposal is incorporated into shall govern the inconsistent terms in the incorporating contract and the
inconsistent terms of the incorporating contract shall be held for naught. If any of the terms of this contract /
proposal are inconsistent with any other contract between parties, the terms of this contract shall govern and
the inconsistent terms in the other contact shall be held for naught.
Unless otherwise stated in this proposal any signed document transmitted by facsim ile machine (fax)
shall be treated in all manner and respects as an original document and the signature of any Party upon a
document transmitted by fax shall be considered a n orig inal signature. Any identical copy of this agreement shall
be treated in all manners and respects as an original document and the signature of a party on an identical copy
shall be considered an original signature.
Warranty on parts and labor is 1 year from completion date and will be null and void if
there is evidence of the sign being tampered with or worked on by anyone else other than
Sign Effectz Inc.
Contract Acceptance: The listed prices specifications and conditions are satisfactory and are hereby
accepted. Sign E ffectz is hereby authorized to do work as specified. Payment will be made as outlined herein. My
signature below indicates that I have read and understand the terms of this contract.
This warranty does not cover loss or damage due to accidents involving the product, acts of criminal nature,
other property disasters or acts of nature. This includes but is not limited to improper installation conditions,
mishandling, misapplication, faul ty wiring, electrical surges, unauthorized attachments or modifications and
improper maintenance.
Except for those warranties specifically and expressively set forth above, seller disclaims any and all warranties
expressed, implied or statutory, including but not limited to, all warranties of merchantability and fitness for
particular purpose.
This equipment has been tested and found to comply with the limits for class “A” dig ital device, pursuant to part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operat ed in a commercial environment. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used properly, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likel y to cause harmful interference. In this
case, the user is required to correct interference at their expense.
Customer Signature _______________________________________________Date__________________
Customer Name (Printed)_______________________________________________________________
Sign Effectz Inc. Rep. ______________________________________________Date_________________
W Drexel Ave & S 27th St,
Franklin, WI 53132
9229 W. Loomis Road
Franklin, WI. 53132
Updated copy per sales 9/23/26 MRM
City of Franklin
REV: SIGN TYPE.
SHEET SIZE.
B
01
AUTHOR:
MRM
DEPT.
CONCEPT
REV.
01
02
03
04
05
06
BILLING ADDRESS:
PROJECT ADDRESS:
DESCRIPTION DATE INIT
07
08
10
09
PROJECT NOTES:
Copyright © 2026 Sign Effectz Inc. All Rights Reserved
CUSTOMER:
“Welcome to Franklin” non-lit FCO
PROJECT:
SCOPE OF WORK:
ACCT. MGR.
ZK
DATE ISSUED:
9/14/26
FCO 1-
CONCEPT DRAWING NO:
1
45299526C 1.1_
SCALE:
1/2” = 1' - 0"
QUOTE:
SHEET NO:
Remove existing FCO,
from monument signage.
Install new non-lit FCO
in its place.
18877
OPTION 1: LOGO WITH TAGLINE
OPTION 2: LOGO WITHOUT TAGLINE
RENDERED VIEW FROM WI-241 FACING WEST
RENDERED VIEW FROM WI-241 FACING WEST
DIMENSIONS BASED ON
ORIGINAL MONUMENT
PRODUCTION ARTWORK:
SURVEY REQUIRED
Welcome to
Welcome to
W Drexel Ave & S 27th St,
Franklin, WI 53132
9229 W. Loomis Road
Franklin, WI. 53132
City of Franklin
REV: SIGN TYPE.
SHEET SIZE.
B
00
AUTHOR:
MRM
DEPT.
CONCEPT
REV.
01
02
03
04
05
06
BILLING ADDRESS:
PROJECT ADDRESS:
DESCRIPTION DATE INIT
07
08
10
09
PROJECT NOTES:
Copyright © 2026 Sign Effectz Inc. All Rights Reserved
CUSTOMER:
“Welcome to Franklin” non-lit FCO
PROJECT:
SCOPE OF WORK:
ACCT. MGR.
ZK
DATE ISSUED:
9/14/26
FCO 1-
CONCEPT DRAWING NO:
2
45299526C 1.1_
SCALE:
1/2” = 1' - 0"
QUOTE:
SHEET NO:
Remove existing FCO,
from monument signage.
Install new non-lit FCO
in its place.
18877
EXISTING NON-LIT MONUMENT - NORTH WEST ELEVATION
1/8" =1 ' - 0" SCALE
1
2
29'-4 3/4"
3'-7 1/4"
41'-1 3/8"
Approximate location of existing spotlights
Grade
3'-6 1/2"
Space for previous
landscaping/foliage
EXISTING NON-LIT MONUMENT - SITE PLAN
1/8" =1 ' - 0" SCALE
2
2
SOIL PLANTING BED
RETAINING WALL
PAVED FOOT PATH
CURVE HAS APPROX. RADIUS OF 74'
APPROX. ARCH LENGTH OF WALL IS 41'6"
41'-1"
Approximate location of existing spotlights
DIMENSIONS BASED ON
ORIGINAL MONUMENT
PRODUCTION ARTWORK:
SURVEY REQUIRED
W Drexel Ave & S 27th St,
Franklin, WI 53132
9229 W. Loomis Road
Franklin, WI. 53132
Updated copy per sales 9/23/26 MRM
City of Franklin
REV: SIGN TYPE.
SHEET SIZE.
B
01
AUTHOR:
MRM
DEPT.
CONCEPT
REV.
01
02
03
04
05
06
BILLING ADDRESS:
PROJECT ADDRESS:
DESCRIPTION DATE INIT
07
08
10
09
PROJECT NOTES:
Copyright © 2026 Sign Effectz Inc. All Rights Reserved
CUSTOMER:
“Welcome to Franklin” non-lit FCO
PROJECT:
SCOPE OF WORK:
ACCT. MGR.
ZK
DATE ISSUED:
9/14/26
FCO 1-
CONCEPT DRAWING NO:
3
45299526C 1.1_
SCALE:
1/2” = 1' - 0"
QUOTE:
SHEET NO:
Remove existing FCO,
from monument signage.
Install new non-lit FCO
in its place.
18877
OPTION 1 PROPOSED REFACE - NORTH WEST ELEVATION
1/8" =1 ' - 0" SCALE
1
3
41'-1 3/8"
Approximate location of existing spotlights
Grade
No existing
landscaping/foliage 200"
Welcome to
2
4
62 3/4"
OPTION 2 PROPOSED REFACE - NORTH WEST ELEVATION
1/8" =1 ' - 0" SCALE
1
3
41'-1 3/8"
Approximate location of existing spotlights
Grade
No existing
landscaping/foliage 181 3/8"
Welcome to
2
5
56"
DIMENSIONS BASED ON
ORIGINAL MONUMENT
PRODUCTION ARTWORK:
SURVEY REQUIRED
W Drexel Ave & S 27th St,
Franklin, WI 53132
9229 W. Loomis Road
Franklin, WI. 53132
Updated copy per sales and color schedule 9/23/26 MRM
City of Franklin
REV: SIGN TYPE.
SHEET SIZE.
B
01
AUTHOR:
MRM
DEPT.
CONCEPT
REV.
01
02
03
04
05
06
BILLING ADDRESS:
PROJECT ADDRESS:
DESCRIPTION DATE INIT
07
08
10
09
PROJECT NOTES:
Copyright © 2026 Sign Effectz Inc. All Rights Reserved
CUSTOMER:
“Welcome to Franklin” non-lit FCO
PROJECT:
SCOPE OF WORK:
ACCT. MGR.
ZK
DATE ISSUED:
9/14/26
FCO 1-
CONCEPT DRAWING NO:
4
45299526C 1.1_
SCALE:
AS NOTED
QUOTE:
SHEET NO:
Remove existing FCO,
from monument signage.
Install new non-lit FCO
in its place.
18877
Welcome to
OPTION 1 PROPOSED ALUM FCO REFACE
1/2" =1 ' - 0" SCALE
2
4
27 1/4"
10"
60 5/8"
200"
8'-0"
Approximate location of existing spotlights
[P-3]
[P-4]
[P-5]
[P-2]
[P-1]
[P-6]
[P-7]
[P-8]
[P-4]
56"
DIMENSIONS BASED ON
ORIGINAL MONUMENT
PRODUCTION ARTWORK:
SURVEY REQUIRED
1
4
SECTION DETAIL - SIDE TYPICAL
1-1/2" =1 ' - 0" SCALE
1
4
1/4" ALUMINUM FCO
PAINTED ON ALL SIDES
STUD MOUNTED ~1" FROM
IRREGULAR STONE SURFACE
8 3/4"
12" 62 3/4"
[P-4] PTM PMS 2995C “LIGHT BLUE”, SATIN -
[P-5] PTM PMS 7408C “YELLOW”, SATIN -
COLOR SCHEDULE:
[P-3] PTM PMS 360C “GREEN”, SATIN -
[P-6] - “GREEN SHADOW”, SATIN TBD
[P-7] - MP PTM “LIGHT BLUE SHADOW”, SATIN TBD
[P-8] - MP PTM “YELLOW SHADOW”, SATIN TBD
LogoCopy
[P-4] SAME AS LOGO COLOR
[P-2] MP BLACK, SATIN -
[P-1] PTM PMS 294 “DARK BLUE”, SATIN -
Font for “Welcome to”:
Roboto Condensed Bold Italic
W Drexel Ave & S 27th St,
Franklin, WI 53132
9229 W. Loomis Road
Franklin, WI. 53132
Updated copy per sales and color schedule 9/23/26 MRM
City of Franklin
REV: SIGN TYPE.
SHEET SIZE.
B
01
AUTHOR:
MRM
DEPT.
CONCEPT
REV.
01
02
03
04
05
06
BILLING ADDRESS:
PROJECT ADDRESS:
DESCRIPTION DATE INIT
07
08
10
09
PROJECT NOTES:
Copyright © 2026 Sign Effectz Inc. All Rights Reserved
CUSTOMER:
“Welcome to Franklin” non-lit FCO
PROJECT:
SCOPE OF WORK:
ACCT. MGR.
ZK
DATE ISSUED:
9/14/26
FCO 1-
CONCEPT DRAWING NO:
5
45299526C 1.1_
SCALE:
AS NOTED
QUOTE:
SHEET NO:
Remove existing FCO,
from monument signage.
Install new non-lit FCO
in its place.
18877
Welcome to
OPTION 2 PROPOSED ALUM FCO REFACE
1/2" =1 ' - 0" SCALE
2
5
27 1/4"
10"
60 5/8"
181 3/8"
8'-0"
Approximate location of existing spotlights
[P-3]
[P-4]
[P-5]
[P-2]
[P-1]
[P-6]
[P-7]
[P-8]
56"
DIMENSIONS BASED ON
ORIGINAL MONUMENT
PRODUCTION ARTWORK:
SURVEY REQUIRED
1
5
[P-4] PTM PMS 2995C “LIGHT BLUE”, SATIN -
[P-5] PTM PMS 7408C “YELLOW”, SATIN -
COLOR SCHEDULE:
[P-3] PTM PMS 360C “GREEN”, SATIN -
[P-6] - “GREEN SHADOW”, SATIN TBD
[P-7] - MP PTM “LIGHT BLUE SHADOW”, SATIN TBD
[P-8] - MP PTM “YELLOW SHADOW”, SATIN TBD
LogoCopy
[P-4] SAME AS LOGO COLOR
[P-2] MP BLACK, SATIN -
[P-1] PTM PMS 294 “DARK BLUE”, SATIN -
SECTION DETAIL - SIDE TYPICAL
1-1/2" =1 ' - 0" SCALE
1
5
1/4" ALUMINUM FCO
PAINTED ON ALL SIDES
STUD MOUNTED ~1" FROM
IRREGULAR STONE SURFACE
Font for “Welcome to”:
Roboto Condensed Bold Italic
16"
Requested By:
John Regetz
Email:
JRegetz@franklinwi.gov
Salesperson:
House Signarama
NO.
Product Summary
QTY
UNIT PRICE
UNIT PRICE
AMOUNT
1
Monument Sign Lettering - Without Tagline
1
$11,590.00
$11,590.00
$11,590.00
"Welcome To":
•
1in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
86.9in W x 12.7in H
Flags:
•
1.5in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
Green: 40.4in W x 16.1in H
•
Blue: 28.1in W x 15.1in H
•
Yellow: 25.3in W x 20.8in H
"Franklin":
•
1.5in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
122.6in W x 26.3in H
"WISCONSIN":
•
1in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
118.8in W x 7.7in H
Bill To:
City of Franklin, WI
6591 S. Whitnall Edge Road
Franklin, WI 53132
US
Installed:
City of Franklin, WI
NW Corner of S 27th & Drexel
Franklin, WI 53132
US
DESCRIPTION:
Monument Sign Lettering
ESTIMATE
EST-31431
PO Number:
Payment Terms:
Cash Customer
https://www.signarama.com/wi-franklinwi.com
10700 West Venture Drive
Unit F
Franklin, WI 53132
(414) 235-3353
Created Date:
9/22/2026
Generated On:
9/22/2026 2:10 PM
Page
1
of
3
•
Price includes installation
•
Price does not include permitting, if required
2
Monument Sign Lettering - With Tagline
1
$12,040.00
$12,040.00
$12,040.00
"Welcome To":
•
1in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
86.9in W x 12.7in H
Flags:
•
1.5in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
Green: 32.8in W x 13in H
•
Blue: 22.8in W x 12.3in H
•
Yellow: 20.6in W x 17in H
"Franklin":
•
1.5in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
122.6in W x 26.3in H
"WISCONSIN":
•
1in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
118.8in W x 7.7in H
"Celebrating Quality of Life":
•
1in D Fabricated aluminum
•
Pin mounted
•
Custom painted
•
118.8in W x 7.7in H
•
Price includes installation
•
Price does not include permitting, if required
3
Permitting
1
$0.00
$0.00
$0.00
•
Signarama is assuming that permitting is not needed, however, if permitting is needed, we can
gladly take care of that as well. Permitting costs would be $200 + the fees from the City.
This estimate is valid for
30
days from the date of issue.
Unless credit terms have been approved a
50%
deposit is required to begin
design or production for all projects over
$500
. All projects under
$500
require
full payment prior to starting design or production. Final payment is due upon
completion of project. If invoice goes
30
days past due, fees will begin to accrue
at a rate of
1.5%
of the total project cost per month.
Generated On:
9/22/2026 2:10 PM
Page
2
of
3
Thank you for choosing Signarama.
Unless Otherwise Specified:
Any tangible or intangible work generated per this document remain the property of Signarama until the order is paid in full. The
order may not be cancelled after customer approval. In case of any deviations from the proof, we will redo the work as quickly as
possible without charge. If you approve or imply approval of the proof, you are responsible for correctness of copy. Our liability is
limited to the replacement of work included in this document, we are not responsible for any subsequent damages, consequential
damages, or otherwise. We will hold completed and or customer supplied items for
60
days after which we will discard it; you will be
billed and held responsible for full payment.
We're a local small business who thrive because of customers like you. Please support us by making timely payments.
Signarama is independently owned and operated
Signature:
Date:
Generated On:
9/22/2026 2:10 PM
Page
3
of
3
Source: City of Franklin website. First collected Oct 16, 2026.