RecordWell Data

Economic-Development-Commission-Special-Meeting-Agenda-Packet-Updated-9-30-2026.pdf

City of Franklin · Milwaukee County · meeting of Sep 30, 2026 · Agenda packets

Open the original document More from City of Franklin

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

Special Meeting of the Franklin Economic Development Commission (EDC) Agenda Franklin City Hall, Hearing Room 9229 W. Loomis Road, Franklin, Wisconsin September 30, 2026 – 6:00 p.m. Chairman Steve Bobowski Cathleen Richard Mike Barber Barbara Wesener Timothy Wachter Alderwoman Michelle Eichmann I. Call to Order and Roll Call A. Pledge of Allegiance II. Citizen Comment Period III. Approve Proposal For The Fabrication And Installation Of A City Sign on an existing sign monument at northwest corner of West Drexel Avenue and South 27th Street. IV. Paleria Brothers LLC, 9848 S 57th St. (FLEX 2020 LLC, PROPERTY OWNER) Minor site plan amendment to allow for photovoltaic (solar) panels for Paleria Brothers LLC, in the City of Franklin Industrial Park. Photovoltaic (solar) panels as a utility feature require EDC approval in accordance with Sec. 12.10(18) of Planned Development Legacy (PDL) 7. V. Adjournment Notice is given that a majority of the Common Council may attend this meeting to gather information about an Agenda item over which they have decision making responsibility. This may constitute a meeting of the Council per State ex rel. Badke v. Greendale Village Board, even though the Common Council will not take formal action at this meeting. Notice is given that upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through appropriate aids and services. For additional information, please contact the Franklin City Clerk’s office at (414) 425-7500. Page 1 of 1 FORMER NORTHWESTERN MUTUAL SIGN DIMENTIONS Mounting Surface (Face) 8’ X 40’ BRAND STANDARDS GUIDE July 17, 2019 Brand Standards GuideBRAND STANDARDS GUIDE PREFERRED REVERSE SINGLE COLOR WHITE PREFERRED SINGLE COLOR BLUE SINGLE COLOR BLACK Brand Standards GuideBRAND STANDARDS GUIDE QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 Preferred Logo The color logo is the preferred version for reproduction. Single Color Logo When circumstances don’t allow for color reproduction, or for applications such as embossing, engraving, vehicle decals, etc., the black, blue or white versions of the logo can be used. 2 MINIMUM SIZE 1.0″ To ensure that the logo is always legible, it should never be reproduced smaller than 1” wide. Brand Standards GuideBRAND STANDARDS GUIDE CLEAR SPACETAGLINE LOGO LOCKUP The space directly surrounding the logo is the clearspace. To ensure the visibility and impact of the Franklin logo, this clearspace must be kept free of other competing visual elements such as type, images and other logos. The clearspace above, below and on each side is equal to the height of the lower case letters in the logo. Our tagline “Celebrating Quality of Life” appears in a specific size, type, color and locked up relationship to the logo. Always use this logo / tagline lockup version when showing the logo with the tagline. The tagline may be used alone as a design element. It appears in a specific type and in a single color – bright blue from the Franklin color palette, black or white. Leave ample clear space around the tagline to maintain readability and impact. Only use an approved tagline art file. Positioning on a page is either bottom left, aligned with the Franklin type in the logomark or bottom right. The Franklin letterhead is an example of the tagline used separately and in the correct position. QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 3 TAGLINE GRAPHIC Typography should be aligned flush left with the Franklin Wisconsin type in the logo, allowing the banner icon to be set-off and emphasized on the left. This alignment is illustrated on the corporate letterhead as shown on page 6. ALIGNING WITH THE LOGOMARK Brand Standards GuideBRAND STANDARDS GUIDE Brand Standards GuideBRAND STANDARDS GUIDE DO NOT Do not skew or stretch Don’t change logo orientation Do not place logo over an image or pattern Don’t apply any filters or textures Do not use alternate colors Don’t apply shadows, glow effects, or outlines Do not fade or screen QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 4 Brand Standards GuideBRAND STANDARDS GUIDE Typographic logo full color Typographic logo single color Brand Standards GuideBRAND STANDARDS GUIDE Franklin banner icon full color Franklin banner icon single color LIMITED USE IDENTITY ELEMENTS QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 5 Celebrating Quality of Life Celebrating Quality of Life Celebrating Quality of Life In limited uses the Franklin banner icon and logotype may be split up. This should only be used in decorative applications such as banners. Some examples of that usage are shown below. Brand Standards GuideBRAND STANDARDS GUIDE GRAPHIC BANNER ELEMENTS TYPEFACES Roboto Sans Condensed and Merriweather Light are the Franklin brand typestyles. Consistent use of these fonts in all communications is integral to maintaining the brand. Both fonts are free downloads for both PC and Mac from many different font websites and are easily found on a Google search. Headline ROBOTO SANS CONDENSED BOLD CAPS Subhead Roboto Sans Condensed Bold Body Copy Roboto Sans Condensed Roboto Sans Condensed Italic Roboto Sans Condensed Light Roboto Sans Condensed Light Italic Merriweather Light Merriweather Light Italic CMYK 100C 85M 30Y 23K RGB 0R 46G 109B HEX 002e6d PANTONE 294 CMYK 62C 0M 96Y 0K RGB 107R 190G 74B HEX 6bbe4a PANTONE 360 CMYK 82C 12M 0Y 0K RGB 0R 167G 227B HEX 00a7e1 PANTONE 2995 COLOR CMYK 0C 26M 100Y 0K RGB 254R 192G 15B HEX fec00f PANTONE 7408 Primary Palette The colors of the primary palette are those found in the Franklin logo. These colors should be used in all materials, publications and communications. QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 6 Distinctive banner graphics have been developed to enhance and strengthen the Franklin brand. They are appropriate for print, digital and dimensional applications. Brand Standards GuideBRAND STANDARDS GUIDE FILE TYPE USAGE File type Description An .EPS file is a vector-based file meaning your logo can be enlarged or made smaller. When increasing or decreasing the size of your logo it will not become blurry. An.EPS file can only be opened/ edited using specific design software. A .JPG file is a pixel-based file that cannot be enlarged but can be made smaller. When increasing the size of your logo it WILL cause pixelation causing your logo to become blurry. A .JPG file will always have a white background. It’s universal and can be opened on any device. A .PNG file is a pixel-based file that cannot be edited or enlarged but can be made smaller. When increasing the size of your logo it WILL cause pixelation causing your logo to become blurry. A .PNG file as a transparent/clear background. It’s universal and can be opened on any device. Usage An .EPS file is used for printing purposes such as signs, business cards, postcards, brochures, t-shirts, hats, etc..EPS files are set up either in Pantone (PMS) colors or CMYK colors. A .JPG file is used for web and electronic file purposes because it has a significantly lower file size and is in RGB color. This file type should not be used for print. A .PNG file is used for web and electronic file purposes because it has a significantly lower file size and is in RGB color. This file type should not be used for print. Software Quark, Illustrator, InDesign, Corel, High resolution printing software Word, PowerPoint, Excel, Web applications Word, PowerPoint, Excel, Web applications QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 7 .PNG .JPG .EPS Brand Standards GuideBRAND STANDARDS GUIDE VEHICLE GRAPHICS Pictured are vehicle decals for Franklin Public Works vehicles. Please contact ???? for approved vehicle decal art. QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 8 Brand Standards GuideBRAND STANDARDS GUIDE Steve Olson Mayor solson@franklinwi.gov p (414) 427-7529 C (414) 651-3367 F (414) 425-6428 City of Franklin 9229 West Loomis Road Franklin, WI 53132 franklinwi.gov City of Franklin Office of the City Clerk Name Here Company Name 1234 Main Street City, ST , 54321 Ovid que inctustrum facia dolorat moluptatur restionse nonsequi nonsere adis audae nus mo qui verfero incim non et omnihic te nobitiur atisti debitatur simi, que corum sit faciis audi optate sit, tem quae endit, omnis aut latenet auda dit volupid quodi vendit, nullantur? Qui sam nonet que ellandam et est, velignia simeniant min conetus sim sandis ut esequam sequas andus sit pernatiunt lautet et quibust quam repudignam, elit aut est ea quatquas modia il excessequunt haribust, sitati aut aut latur aut aut dis mo illupta eaque rem quo optasin culla es nonsecu ptatemporem erio. Nam nonest, et harunt. Uditius et pa ducipsam voluptatur acea que comnistorum fugias rehenempore doluptas sinvelis etur, ium ut As autem aceperepe culpa voluptaqui reius, consedisit, seque vit, comnim volest eossunt ustrum alis sam anis de sanimus, consente omnis modiani officidus dolorum, sedicita essimperum harum senimil idebisciis dolo doluptatur, corior archil idic tem et milis et omnis aceptis pe molorro eos expliant eos am, non re neverione ssecum utem velit rate lam facit rem. Simollabo. Et aut doluptatusa nonse di in paritet intis alitas alicitia in corem voluptas sanimus et moluptatiume accus. Ma et aut aces doluptatiunt et aribernat eosae dolecto moluptatem faccae doluptas inciis est es natur aut ped quis aut ut harion con poribus nullaceaquam nonem aut haris cus aborestrum rehendendio idunti volupta sanitium as con re peris debis seque vel eniminc itiur? Iquam rest, et ention nonsequ assitio nsenti quis aborerchit ommoluptat aliqui debitio. Nem. Namus es ped unt antibernam es dest omnis as sequi aut quis in peliae re ercient fugias dolut occus, autatatquas sunt ipsaero voluptatatia de 9229 West Loomis Road Franklin, WI 53132-9630 p (414) 427-7566 F (414) 427-7691 franklinwi.gov Name Here Company Name 1234 Main Street City, ST , 54321 City of Franklin 9229 West Loomis Road Franklin, WI 53132-9630 City of Franklin 9229 West Loomis Road Franklin, WI 53132-9630 Name Here Company Name 1234 Main Street City, ST , 54321 BUSINESS SYSTEM QUESTIONS? Contact: First Lastname, Title, flastname@franklinwi.gov / (414) 000-0000 9 Stationery Templates Formats have been established for Franklin stationery. Always use approved stationery documents. Templates are available from ?????. City of Franklin, Wisconsin Master Logos COLOR SPACE 4C PMS / CMYK / RGB FILE FORMATS EPS / PNG / JPG COLOR SPACE Black FILE FORMATS EPS / PNG / JPG Taglines COLOR SPACE 1C PMS / CMYK / RGB FILE FORMATS EPS / PNG / JPG COLOR SPACE 3C PMS / CMYK / RGB FILE FORMATS EPS / PNG COLOR SPACE White FILE FORMATS EPS / PNG COLOR SPACE Black FILE FORMATS EPS / PNG / JPG COLOR SPACE White FILE FORMATS EPS / PNG CITY OF FRANKLIN REPORT TO THE ECONOMIC DEVELOPMENT COMMISSION Meeting of September 30, 2026 Minor Site Plan amendment, Solar Facility RECOMMENDATION Minor Site Plan Amendment, Solar: Planning Staff recommends approval of the Site Plan Amendment, subject to the conditions in the Draft Resolution. Project Name: Paleria Brothers LLC Solar Property Owner: FLEX 2020, LLC Applicant: Paleria Brothers LLC Property Address/Tax Key Number: 9848 S 57th St, 899 0005 000 Aldermanic District: District 4 Agent: Tawni Latterell, Wolf River Electric Zoning District: Planned Development Legacy 7 Use of Surrounding Properties: PDL 18 (east) PDL 7 (south and west) LI Limited Industrial (north) Staff Planner: Marion Ecks, AICP, Principal Planner Minor Site Plan Amendment and Utility Location: The applicant has submitted a Minor Site Plan amendment to allow for installation of roof - mounted photovoltaic (solar) panels. Since this facility is located in the Franklin Industrial Park, Planned Development Legacy No. 7 requires that the location of utilities such as solar panels be subject to approval by the Economic Development Commission (EDC). City Development staff reviewed it and informed the applicant of this requirement. Site Plan: The property is located on the east side of South 57 th Street and the development consists of a single industrial building, outdoor storage areas, and related parking. The eastern half of the parcel is a wetland area. The proposed solar installation consists of two groups of solar panels totaling 108 panels, all on the building roof. Metering equipment will be mounted on the east wall of the building. There are no ground-based improvements or additional impervious surface proposed. As a result, there are no proposed impacts to any natural resources on the property. There will be no changes to the building’s architecture. 2 PDL 7 allows a maximum height of 50’; the proposed panels will be a maximum of two (2) feet from the roof and do not exceed the height requirement. The applicant states that the panels will not be visible from the ground and will therefore not require screening. Staff rec ommends a condition that if roof mounted mechanical equipment is visible from any public street, the owner will be responsible for providing appropriate screening. The location of utilities requires approval of the Economic Development Commission (EDC) (Sec. 12.10(18)). Staff Recommendation: Minor Site Plan amendment:, City Development staff recommend s approval of the proposed Site Plan Amendment application, subject to the following conditions: • If roof mounted mechanical equipment is visible from any public street, the owner will be responsible for providing appropriate screening. The attached Site Plan Amendment resolution includes the conditions listed above. ECONOMIC DEVELOPMENT COMMISSION OF THE CITY OF FRANKLIN, WISCONSIN [Draft 09-23-26] RESOLUTION NO. 2026-_____ A RESOLUTION APPROVING A MINOR SITE PLAN AMENDMENT TO ALLOW FOR INSTALLATION OF SOLAR PANELS FOR PALERIA BROTHERS LLC 9848 S 57TH ST. (FLEX 2020 LLC, PROPERTY OWNER) WHEREAS, Paleria Brothers LLC , having petitioned the City of Franklin for approval of a minor site plan amendment to allow for photovoltaic (solar) panels for Paleria Brothers LLC, in the City of Franklin Industrial Park, property located at 9848 S 57th St., Franklin Industrial Park; and WHEREAS, the Economic Development Commission having reviewed the proposed site plan amendment and found same to be in compliance with and in furtherance of the standards of Planned Development District No. 7. NOW, THEREFORE, BE IT RESOLVED, by the Economic Development Commission of the City of Franklin, Wisconsin, that the site plan amendment City file - stamped September 14, 2026, attached hereto and incorporate herein as Exhibit A, be and the same is approved, subject to the following conditions: 1. That the Paleria Brothers LLC site plan amendment shall be constructed pursuant to such proposed plans within one year from the date of adoption of this Resolution, or this Resolution and all rights and approvals granted hereunder shall be null and void, without any further action by the Economic Development Commission. 2. The Economic Development Commission (EDC) hereby approves the location of the photovoltaic (solar) panels as a utility fe ature in accordance with Sec. 12.10(18) of Planned Development Legacy (PDL) 7. 3. The applicant must obtain a building permit from the Inspection Services Department prior to the construction of the proposed solar facility. 4. The applicant must obtain approval of utilities, grading and erosion control from the Engineering Department prior to any land disturbance activities. 5. If r oof mounted mechanical equipment is visible from any public street, the owner will be responsible for providing appropriate screening. Introduced at a regular meeting of the Economic Development Commission of the City of Franklin this _______ day of ____________________, 2026. Passed and adopted at a regular meeting of the Economic Development Commission of the City of Franklin this _______ day of ____________________, 2026. APPROVED: _________________________________ Chairman ATTEST: __________________________________ Vice Chairman AYES ______ NOES ______ ABSENT ______ [9/8/2026] Sent via Email & US Mail Department of City Development City of Franklin 9229 W. Loomis Road Franklin, WI, 53132 mecks@franklinwi.gov Re: Project Narrative Paleria Brothers LLC Project Overview The proposed project consists of the installation of two roof-mounted photovoltaic (PV) solar energy systems at the existing commercial building located at 9848 S 57th St, Franklin, WI 53132 . Both systems will be installed on the existing roof structure utilizing a low-profile, ballasted racking system and will be interconnected with the building's existing electrical infrastructure at their respective system voltages. The proposed racking system will be designed and installed to meet the applicable structural load requirements of the existing building. The low-profile design will minimize the overall height and visual impact of the solar installation. The top of the module rows will be approximately two feet above the roof surface , which is well below the existing building parapet. As a result, the solar arrays will be virtually invisible from ground level . The project will be interconnected with the We Energies electrical distribution system. All equipment and installation will be performed in accordance with the approved electrical and structural plans, applicable Wisconsin codes and standards, We Energies interconnection requirements, and the manufacturer's installation instructions. System 1 – 28.800 kW DC / 25.000 kW AC System 1 will consist of 72 photovoltaic modules , each rated at 400 watts, for a total installed DC capacity of 28.800 kW DC . The PV modules will be installed using a low-profile, ballasted roof-mounted racking system . The racking system will be designed to meet the applicable structural load requirements and will be installed in accordance with the approved project structural design and manufacturer's installation requirements. DC power generated by the array will be connected to one 25.000 kW AC inverter . The inverter will convert the array's DC output to AC power for utilization by the building electrical system. System 1 will be interconnected with the building's existing 208-volt electrical system . The AC interconnection, overcurrent protection, disconnecting means, grounding and bonding, conductor sizing, and associated electrical equipment will be installed as shown on the approved electrical plans and in accordance with applicable code requirements and We Energies interconnection requirements. System 2 – 43.200 kW DC / 36.000 kW AC System 2 will consist of 108 photovoltaic modules , each rated at 400 watts, for a total installed DC capacity of 43.200 kW DC . The PV modules will be installed using a low-profile, ballasted roof-mounted racking system . The racking system will be designed to meet the applicable structural load requirements and will be installed in accordance with the approved project structural design and manufacturer's installation requirements. DC power generated by the array will be connected to one 36.000 kW AC inverter . The inverter will convert the DC output of the PV array to AC power for utilization by the building electrical system. System 2 will be interconnected with the building's existing 480-volt electrical system . The AC interconnection, overcurrent protection, disconnecting means, grounding and bonding, conductor sizing, and associated electrical equipment will be installed as indicated on the approved electrical plans and in accordance with applicable code requirements and We Energies interconnection requirements. Roof-Mounted Installation Both PV arrays will be located on the existing building roof. The module layout will maintain required roof access, equipment access, fire-access pathways, setbacks, and other clearances required by the applicable building and fire codes and the authority having jurisdiction. The ballasted, low-profile racking system will be designed to meet the structural load requirements of the existing roof and will be installed as detailed in the approved project structural plans. The ballasted system is intended to minimize roof penetrations while providing the required stability and structural performance for the PV arrays. The low-profile configuration will keep the solar modules below the existing building parapet. The top of the module rows will be approximately two feet above the roof surface , well below the parapet, making the solar installation virtually invisible from the ground and minimizing its visual impact on the surrounding area. PV wiring will be routed from the roof-mounted modules to the associated inverter equipment. DC and AC conductors will be properly supported, protected, identified, and routed in accordance with applicable electrical code requirements. The systems will include required grounding and bonding, overcurrent protection, disconnecting means, rapid shutdown provisions where applicable, equipment labeling, and other required safety components. Electrical Interconnection The two PV systems will operate as separate generating systems and will connect to separate existing electrical systems within the facility: ● System 1: 28.800 kW DC / 25.000 kW AC, interconnected at 208 volts through one 25.000 kW AC inverter. ● System 2: 43.200 kW DC / 36.000 kW AC, interconnected at 480 volts through one 36.000 kW AC inverter. The combined project capacity is 72.000 kW DC and 61.000 kW AC . The PV systems are intended to provide on-site electrical generation and offset facility electrical consumption. The systems will be interconnected with the existing electrical service in accordance with the approved plans and the requirements of We Energies . Utility interconnection equipment, metering, protection, and associated requirements will be provided and installed as required by the utility and approved project design. Completion and Commissioning Upon completion of installation, all PV modules, racking, inverters, wiring, disconnects, and associated electrical equipment will be inspected and tested. The systems will be commissioned in accordance with the equipment manufacturers' requirements and the approved project plans. The completed installation will be subject to the required inspections and utility approval prior to final operation. The installation will comply with applicable Wisconsin building and electrical requirements, approved structural and electrical plans, manufacturer installation requirements, and We Energies interconnection requirements. Sincerely, Cody M. Rossmann Senior Project Manager Wolf River Electric cody@wolfriverelectric.com Direct: (763) 297-3597 Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 0.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 COVER SHEET PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM9848 S 57TH ST, FRANKLIN, WI 53132, USA SYSTEM SIZE: 43.200 kW DC36.000 kW ACMODULE TYPE & AMOUNT:(108) WAAREE ARKA SERIES WSMDI-400 [400W]MODULE DIMENSIONS:(L/W/H) 75.75"/40.86"/1.37" INVERTER:(1) CPS SCA36KTL-DO/US-480INTERCONNECTION METHOD: LINE SIDE TAP SCALE: NTS2VICINITY MAPPV 0.0SCALE: NTS1SATELLITE VIEWPV 0.0 42.865667, -87.98694042.865667, -87.986940 108 MODULES - ROOF MOUNTED - 43.200 kW DC, 36.000 kW ACGENERAL ELECTRIC NOTES:1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC2017.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTEDPRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAMERACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHENTHEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, ITSHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47 AND 250.50 THROUGH 60AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTINGBUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM ISINACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED ATTHE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGERTHAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDEFOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNEDAND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THEROOF SURFACE.10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSEDTO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.11.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDINGTO NEC 690.35(F).12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONSHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOFMOUNTED TRANSITION BOXES AND SWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NECARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION IN ACCORDANCE WITH NEC 690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATIONWITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUITRUNS AS REQUIRED PER NEC. AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF FRANKLINZONING: CITY OF FRANKLINUTILITY: WE ENERGIESUTILITY METER NUMBER: 159 016 581 GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C SHEET INDEX:PV 0.0:COVER SHEETPV 0.1:PLOT PLANPV 1.0:SITE PLANPV 1.1:ATTACHMENTPV 1.2:STRING LAYOUTPV 1.3:EQUIPMENT ELEVATIONS 1.0: MOUNT DETAILSS 1.1: MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:WIRE CALCULATIONE 1.3:WARNING LABELSE 1.4:PLACARDD 1.1+:EQUIPMENT SPEC SHEETGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa.2017 NATIONAL ELECTRICAL CODEb.2024 WISCONSIN UNIFORM DWELLING CODEc.2015 INTERNATIONAL BUILDING CODEd.2015 INTERNATIONAL MECHANICAL CODEe.2015 INTERNATIONAL FUEL GAS CODEf.2015 INTERNATIONAL EXISTING BUILDING CODEg.2015 INTERNATIONAL ENERGY CONSERVATION CODEh.ANY OTHER LOCAL AMENDMENTS 339'-10" 392'-5" 326'-76" 468'-8" 53'-6" 50'-9"191'-7"74'-5" N Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 0.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 PLOT PLAN SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.1 PARCEL: 8990005000PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT: 3.21 ACRES PROPERTY LINE ROOF ACCESS POINT DRIVEWAY ROOF #1(108) WAAREE ARKA SERIES WSMDI-400[400W]SLOPE: 15°AZIM.: 180° MEXISTING INTERIOR MAIN SERVICE PANELEXISTING CL20 METER #159 016 581. NEW AC DISCONNECTNEW CPS SCA36KTL-DO/US-480 INVERTER FENCEPROPERTY LINE PROPERTY LINEPROPERTY LINENOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. TREES CT 9848 S 57TH STFRONT OF BUILDING DRIVEWAY EXISTING CT CABINET acI ACEXISTING TRANSFORMER FENCE MAIN BUILDINGTNEW UTILITY AC DISCONNECT 2' MAX SPACING REVISION DATE: OCT, 16, 2025 N Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 SITE PLAN SCALE: 1/8" = 1'-0"1SITE PLANPV 1.0 ROOF SECTIONS SYSTEM LEGENDACNEW UTILITY AC DISCONNECTEXISTING EXTERIOR CL20 METER#159 016 581. ROOF FIRE SUPPRESSION SPRINKLERSYSTEM:NOTOTAL ROOF AREA:18271.99ft2 TOTAL MODULE AREA:2321.36ft2 TOTAL AREA COVERED:12.70% = ROOF OBSTRUCTIONS= EXTERIOR RUN= CONDUIT ROOF TOP JUNCTION BOX ROOF ACCESS POINT acNEW AC DISCONNECTCTEXISTING EXTERIOR CT CABINET MODULE - 108SLOPE - 15°AZIMUTH - 180°MATERIAL - TPOROOF #01 108 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULES ROOF #01 48" FIRE SETBACK 9848 S 57TH STFRONT OF BUILDING INEW (1) CPS SCA36KTL-DO/US-480 3 PHASESTRING INVERTER NOTE:ROOFTOP RUN CONDUIT SHALL BE MINIMUM7/8 INCHES FROM ROOF SURFACE. MEXISTING INTERIOR MAIN SERVICE PANEL M 48" FIRE SETBACK 48" FIRE SETBACK 48" FIRE SETBACK 48" FIRE SETBACKCTAC ac NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. I 2' MAX SPACING SYSTEM #1 AT 208V(72) WAAREE ARKA SERIES WSMDI-400 [400W] SYSTEM #2 AT 480V(108) WAAREE ARKA SERIES WSMDI-400 [400W] 2' MAX SPACING 48" FIRE SETBACK REVISION DATE: OCT, 16, 2025 NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ATTACHMENTSCALE: 1/8" = 1'-0"1 ATTACHMENTPV 1.1 SYSTEM LEGENDUNIRAC RM10 EVO NORTHROW BAY (26 Nos)UNIRAC RM10 EVO FIELDBAY (158 Nos)TOTAL NO. OF BALLAST BLOCK (387 NOS)= RM10 ATTACHMENTKIT(22 Nos)= MID SUPPORT (87 NOS) REVISION DATE: OCT, 16, 2025 1.11.12.12.13.1 3.14.1 4.16.19.19.18.18.17.17.16.15.15.1NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 STRING LAYOUT SCALE: 1/8" = 1'-0"1STRING LAYOUTPV 1.2 SYSTEM LEGEND1.1INVERTER #112 MODULES1.21.312 MODULES12 MODULES1.412 MODULES1.51.612 MODULES12 MODULES1.712 MODULES1.81.912 MODULES12 MODULES REVISION DATE: OCT, 16, 2025 Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 EQUIPMENTELEVATIONUNDERGROUNDSERVICESCALE: NTS1EQUIPMENT ELEVATIONPV 1.3 FROM PV ARRAYFROM (E)CT CABINETWITH CL20METER<10'(E) CT CABINETWITH CL20METER#14 147 162(E) MAINSERVICE PANEL INTERIOR WALLEXTERIOR WALL 4'(N) UTILITY AC DISCONNECT (N) INVERTER(E) CT CABINETWITH CL20METER#159 016 581(N) AC DISCONNECT ON ROOF UNDERGROUNDSERVICETO (E) MAIN SERVICE PANEL. 14"1' 1'-12"12"16"1'-28"53 13 4RM10 EVO NORTHROW BAYTOP ROOF SURFACE PV MODULERM10 EVO FIELD BAYEVO MOD CLAMP KIT 1ATTACHMENT DETAILS 1.0SCALE: NTSSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address S 1.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNT DETAIL GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address S1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNT DEATILS (NEW) CPS SCA36KTL-DO/US-480INVERTER 480 VAC, 43.5A, 97.4% CECWEIGHTED EFFICIENCYUL 1741 LISTEDDC G1 L1L1L2L2L1L1L2L2L1L1L2L2L1L1L2L22 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.112 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.212 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.312 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.412 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.512 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.6(NEW) UTILITY ACDISCONNECT SWITCH,SQUARE D VH362NRB60A,FUSED, 277/480V, 3PHASE, 4 WIRE,NEMA3RSURGE PROTECTIVE DEVICEREFERENCE POINT OFAPPLICABILITY (RPA) 108 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULES GN L2L1MTO UTILITY GRIDL3 EXISTING 480V/225ABUSBAR RATING,MAIN SERVICEPANEL, 3P,4W N EXISTING GROUNDINGELECTRODE SYSTEM EPOINT OFINTERCONNECTIONLINE SIDE TAP225A 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.712 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.8G L1L1L2L2L1L1L2L2L1L1L2L2 (NEW) JUNCTION BOX#2600 V, NEMA 4UL LISTED L1L1L2L2(NEW) JUNCTION BOX#1600 V, NEMA 4UL LISTED L1L1L2L2G 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.91A2A (NEW) JUNCTION BOX#3600 V, NEMA 4UL LISTED 3 E 60A FUSESGVISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE<10' NEW GROUNDINGELECTRODE SYSTEMG (NEW) AC DISCONNECTSWITCH,SQUARE D VHU362RB 60A,NON-FUSED,277/480V, 3 PHASE, 4WIRE, NEMA3R34 EXISTING 400A CT CABINET3-PHASE, 4-W, 600VCAT. NO WECT4-4L13ENCLOSURE TYPE 1/3REXISTING 20A CL20METER 3-PHASE,4-W, 480V R FUSESSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES ELECTRICALDIAGRAM DC System Size (Watts)AC System Size (Watts)Total Module CountPhotovoltaic System4320036000108NOTE: UTILITY AC DISCONNECT TO BEINSTALLED WITHIN 10FT FROM UTILITY METER.Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)DescriptionInverter Output (PV Wire)EGC (Bare Copper Ground)Inverter Output (THWN-2)EGC (THWN-2)Inverter Output (THWN)EGC (THWN)Wire Gauge# of Conductors/ColorConduit TypeConduit SizeTag #8 AWG (AL)8(4L1,4L2,4L3), 2(L1,L2,L3)1 BARE1 (GRN)4(L1, L2, L3, N)1 (GRN)Free AirFree AirPVCSCH 80 PVCN/AN/A1"1" 1, 1A1, 1A2, 2A2, 2A3312 AWG6 AWGSCH 80 PVC12 AWG12 AWG3 AWG (AL)1-1/4"8(4L1,4L2,4L3), 2(L1,L2,L3)PVC Inverter Output (THWN)SCH 80 PVC44(L1, L2, L3, N) NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C [480V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA36KTL-DO/US-480MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER61.2 KWNOMINAL AC VOLTAGE480 VOLTSMAX. AC CURRENT43.5 AMPSAC POWER36000 W3 AWG (AL)1-1/4"1-1/4" REVISION DATE: SEP, 27, 2025REVISION DATE: SEP, 27, 2025 REVISION DATE: OCT, 16, 2025REVISION DATE: NOV, 12, 2025 NOTE:LOAD-SIDE TAPS ARE ONLY ALLOWABLE INSIDETRANSOCKET IF THEY ARE LANDED ON THE TRANSOCKET’SLOAD SIDE BUS; SPLICING ONTO THE EXISTING SERVICEENTRANCE CONDUCTORS IS NOT ACCEPTABLE FOR THISPURPOSE.REVISION DATE: NOV, 12, 2025 Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 WIRECALCS Rooftop conductor ampacities designed in compliance with art. 690.8,Tables 310.15(B)(16), 310.15(B)(2)(a). Location specific temperatureobtained from ASHRAE 2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-24°C32°C CONDUIT HEIGHT7/8" CONDUCTOR TEMPERATURE RATE (ON ROOF)90°C·Designed according to and all code citations are relevant to the 2017 National Electrical Code.·Tag 2-Use 96% temperature derate for conditions of use (On roof)·Tag 3 - Use 96% temperature derate for conditions of use (adjusted ambient)·System grounding & bonding designed in compliance with 690.47(C)3 and 250.64(E)·Equipment shall be listed, tested, and marked to withstand the available short circuit currentELECTRICAL NOTES Conductor Calculations NUMBER OF CURRENTCARRYING CONDUCTORS INCONDUIT4-67-910-20PERCENT OF VALUES.80.70.50 CONDUCTOR TEMPERATURE RATE (OFF ROOF)75°CTEMP 0.5°54°CTHIS PANEL IS FED BY MULTIPLE SOURCES (UTILITYAND SOLAR)AC OUTPUT CURRENT ACCORDING TO ART. 690.8(B)(1)NOMINAL AC VOLTAGE480V43.5A OCPD Calculations[480V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA36KTL-DO/US-480MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER61.2 KWNOMINAL AC VOLTAGE480 VOLTSMAX. AC CURRENT43.5 AMPSAC POWER36000 W Breakers sized according to continuous duty output current.Inverter Output Current X (1.25[art. 690.8(A)]) X (139 Max AC current inverter)Inverter #1 = Output Current w/ continuous duty = 43.5A <= 60A Breakersystem output current w/ continuous duty = 54.38 <= 60A (System OCPD)Wire gauge calculated from code art. 310.15(B)(16) with ambient temperature calculations from art. 310.15(B)(2)(a).For "On Roof" conductors we use the 90°C column ampacity, the relevant ambient temperature adjustment, and racewayfill adjustments from 310.15(B)(16). Conduit shall be installed at least 7/8" above the roof surface.For "Off Roof" conductors we use the 75°C column ampacity, or the 75°C column ampacity with the relevant ambienttemperature and raceway fill adjustments, whichever is less.The rating of the conductor after adjustments MUST begreater than, or equal to, the continuous duty output current.Calculation Example - Wire Rating x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous DutyOutput Current(Tag 2 On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.7 (8 Conductors) = 20.16A > 14.15A (Tag 2A On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 1.0 (2 Conductors) = 28.8A > 14.15A (Tag 3 & 4 Off Roof):3 gauge AL wire rated for 75A , 75A x 0.94 x 0.8 = 56.4A > 54.38A (System Output Current) PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 WARNINGLABELS LABEL LOCATION: RSD INITIATION DEVICE, UTILITY AC DISCONNECTPER CODE: NEC 690.56(C)(2) ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, UTILITY ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7) LABEL LOCATION: UTILITY AC DISCONNECTPER CODE: NEC 690.13(B) LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C) ! LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: UTILITY AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2) DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)! PHOTOVOLTAIC POWER SOURCEPHOTOVOLTAIC SYSTEM UTILITY AC DISCONNECTRATED AC OUTPUT CURRENT: 43.50 A NOMINAL OPERATING AC VOLTAGE: 480 V TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMPHOTOVOLTAIC UTILITYAC DISCONNECT Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.4 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 PLACARDServiced by Wolf River ElectricContact: (763) 229-6662 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATED AS SHOWNCAUTION ! MULTIPLE SOURCES OF POWERN9848 S 57TH STMAIN SERVICE PANEL (480V)CL 20 METER (480V) UTILITY AC DISCONNECT (480V)INVERTER (480V)CT CABINET (480V)AC DISCONNECT (480V) INVERTER (208V)AC DISCONNECT (208V)MAIN SERVICE PANEL(208V)CL 20 METER(208V) UTILITY AC DISCONNECT (208V)CTCABINET(208V)FUSEDDISCONNECT(208V) Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MODULE SPECSHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 INVERTER SPECSHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 CERTIFICATE OFCOMPLIANCE Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.4 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 SPD SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.5 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNTING DETAIL SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.6 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ACD SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.7 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040 ELECTRICALCONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ACD SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 0.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 COVER SHEET PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM9848 S 57TH ST, FRANKLIN, WI 53132, USASHEET INDEX:SYSTEM SIZE: 28.800 kW DC25.000 kW ACMODULE TYPE & AMOUNT:(72) WAAREE ARKA SERIES WSMDI-400 [400W]MODULE DIMENSIONS:(L/W/H) 75.75"/40.86"/1.37" INVERTER:(1) CPS SCA25KTL-DO/US-208INTERCONNECTION METHOD: LOAD SIDE CONNECTION SCALE: NTS2VICINITY MAPPV 0.0SCALE: NTS1SATELLITE VIEWPV 0.0 42.865667, -87.98694042.865667, -87.986940 PV 0.0:COVER SHEETPV 0.1:PLOT PLANPV 1.0:SITE PLANPV 1.1:ATTACHMENTPV 1.2:STRING LAYOUTPV 1.3:EQUIPMENT ELEVATIONS 1.0: MOUNT DETAILSS 1.1: MOUNT DETAILSE 1.1:3-LINE DIAGRAME 1.2:WIRE CALCULATIONE 1.3:WARNING LABELSE 1.4:PLACARDD 1.1+:EQUIPMENT SPEC SHEET 72 MODULES - ROOF MOUNTED - 28.800 kW DC, 25.000 kW ACGENERAL ELECTRIC NOTES:1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC2017.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTEDPRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAMERACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHENTHEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, ITSHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47 AND 250.50 THROUGH 60AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTINGBUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM ISINACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED ATTHE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGERTHAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDEFOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNEDAND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THEROOF SURFACE.10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSEDTO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.11.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDINGTO NEC 690.35(F).12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONSHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOFMOUNTED TRANSITION BOXES AND SWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NECARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION IN ACCORDANCE WITH NEC 690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATIONWITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUITRUNS AS REQUIRED PER NEC. AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF FRANKLINZONING: CITY OF FRANKLINUTILITY: WE ENERGIESUTILITY METER NUMBER: 14 147 162 GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = CGOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa.2017 NATIONAL ELECTRICAL CODEb.2024 WISCONSIN UNIFORM DWELLING CODEc.2015 INTERNATIONAL BUILDING CODEd.2015 INTERNATIONAL MECHANICAL CODEe.2015 INTERNATIONAL FUEL GAS CODEf.2015 INTERNATIONAL EXISTING BUILDING CODEg.2015 INTERNATIONAL ENERGY CONSERVATION CODEh.ANY OTHER LOCAL AMENDMENTS 339'-10" 392'-5" 326'-76" 468'-8" 53'-6" 50'-9"191'-7"136'-7" N Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 0.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 PLOT PLAN SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.1 PARCEL: 8990005000PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT: 3.21 ACRES PROPERTY LINE ROOF ACCESS POINT DRIVEWAY ROOF #1(72) WAAREE ARKA SERIES WSMDI-400 [400W]SLOPE: 15°AZIM.: 180° MEXISTING INTERIOR MAIN SERVICE PANELEXISTING CL20 METER #14 147 162. NEW AC DISCONNECTNEW CPS SCA25KTL-DO/US-208 INVERTER EXISTING FUSED DISCONNECT FENCEPROPERTY LINE PROPERTY LINEPROPERTY LINENOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. TREES CT 9848 S 57TH STFRONT OF BUILDING DRIVEWAY EXISTING CT CABINETacIACEXISTING TRANSFORMER FENCE MAIN BUILDINGTNEW UTILITY AC DISCONNECT FD 2' MAX SPACING REVISION DATE: OCT, 16, 2025 N Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 SITE PLAN SCALE: 1/8" = 1'-0"1SITE PLANPV 1.0 ROOF SECTIONS SYSTEM LEGEND ACNEW UTILITY AC DISCONNECT EXISTING EXTERIOR CL20 METER#14 147 162. ROOF FIRE SUPPRESSION SPRINKLERSYSTEM:NOTOTAL ROOF AREA:18271.99ft2 TOTAL MODULE AREA:1547.57ft2 TOTAL AREA COVERED:8.47% = ROOF OBSTRUCTIONS= EXTERIOR RUN= CONDUIT ROOF TOP JUNCTION BOX ROOF ACCESS POINT CTEXISTING EXTERIOR CT CABINET MODULE - 72SLOPE - 15°AZIMUTH - 180°MATERIAL - TPOROOF #01 72 NEW WAAREE ARKA SERIES WSMDI-400[400W] MODULES ROOF #01 48" FIRE SETBACK 9848 S 57TH STFRONT OF BUILDING INEW (1) CPS SCA25KTL-DO/US-208 3 PHASESTRING INVERTER NOTE:ROOFTOP RUN CONDUIT SHALL BE MINIMUM7/8 INCHES FROM ROOF SURFACE. MEXISTING INTERIOR MAIN SERVICE PANELFDEXISTING FUSED DISCONNECTacNEW AC DISCONNECT M 48" FIRE SETBACK 48" FIRE SETBACK 48" FIRE SETBACK 48" FIRE SETBACK CTFDIac NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER. ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTION IN LOCATIONS WHERE THE ACCESSPOINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. AC 2' MAX SPACING SYSTEM #2 AT 480V(108) WAAREE ARKA SERIES WSMDI-400 [400W] SYSTEM #1 AT 208V(72) WAAREE ARKA SERIES WSMDI-400 [400W] 2' MAX SPACING REVISION DATE: OCT, 16, 2025 NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ATTACHMENTSCALE: 1/8" = 1'-0"1 ATTACHMENTPV 1.1 SYSTEM LEGENDUNIRAC RM10 EVO NORTHROW BAY (30 Nos)UNIRAC RM10 EVO FIELDBAY (106 Nos)TOTAL NO. OF BALLAST BLOCK (264 NOS)= RM10 ATTACHMENTKIT(15 Nos)= MID SUPPORT (53 NOS) REVISION DATE: OCT, 16, 2025 1.11.11.21.2 1.3 1.31.41.41.51.51.61.6 NSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 STRING LAYOUT SCALE: 1/8" = 1'-0"1STRING LAYOUTPV 1.2 SYSTEM LEGEND1.1INVERTER #112 MODULES1.21.312 MODULES12 MODULES1.412 MODULES1.51.612 MODULES12 MODULES REVISION DATE: OCT, 16, 2025 Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address PV 1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 EQUIPMENTELEVATIONUNDERGROUNDSERVICESCALE: NTS1EQUIPMENT ELEVATIONPV 1.3 FROM PV ARRAYFROM (E)FUSEDDISCONNECT<10'(E) CT CABINETWITH CL20METER#14 147 162(E) MAINSERVICE PANEL INTERIOR WALLEXTERIOR WALL 4'(N) UTILITY AC DISCONNECT (N) INVERTER(E) CT CABINETWITH CL20METER#159 016 581(N) AC DISCONNECT ON ROOF UNDERGROUNDSERVICETO (E) MAIN SERVICE PANEL.(E) FUSED DISCONNECT 14"1' 1'-12"12"16"1'-28"53 13 4RM10 EVO NORTHROW BAYTOP ROOF SURFACE PV MODULERM10 EVO FIELD BAYEVO MOD CLAMP KIT 1ATTACHMENT DETAILS 1.0SCALE: NTSSheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address S 1.0 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNT DETAIL GENERAL STRUCTURAL NOTES:a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USINGTHE UNIRAC RM10 EVO BALLAST.1.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2.GROUND SNOW LOAD = 30 psf3.WIND SPEED = 115 mph4.EXPOSURE CATEGORY = C Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address S 1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNT DEATILS (NEW) CPS SCA25KTL-DO/US-208INVERTER 208 VAC, 69.5A, 96.5% CECWEIGHTED EFFICIENCYUL 1741 LISTEDDC G1 L1L1L2L2L1L1L2L2L1L1L2L2L1L1L2L22 12 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.112 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.212 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.312 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.412 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.512 WAAREE ARKA SERIES WSMDI-400 [400W]MODULES IN CIRCUIT #1.672 NEW WAAREE ARKA SERIESWSMDI-400 [400W] MODULESGL1L1L2L2(NEW) JUNCTION BOX#2600 V, NEMA 4UL LISTEDL1L1L2L2(NEW) JUNCTION BOX#1600 V, NEMA 4UL LISTED1A2A(NEW) UTILITY ACDISCONNECT SWITCH,SQUARE D D323NRB100A,FUSED, 120/208V,3 PHASE, 4 WIRE,NEMA3RSURGE PROTECTIVE DEVICEREFERENCE POINT OFAPPLICABILITY (RPA)GN L2L1MTO UTILITY GRIDL3 EXISTING 208V/225ABUSBAR RATING,MAIN SERVICEPANEL, 3P,4W N EXISTINGGROUNDINGELECTRODESYSTEM E POINT OFINTERCONNECTIONLOAD SIDE CONNECTION 225A 3 E 90A FUSESGVISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE<10' G (NEW) AC DISCONNECTSWITCH,SQUARE D DU323100A,NON-FUSED,120/208V, 3 PHASE, 4WIRE, NEMA3R33 EXISTING 400AFUSEDDISCONNECTCAT. NO PT325CLASS T FUSIBLEPULL OUT SWITCH EXISTING 400A CT CABINET3-PHASE, 4-W, 208VCAT. NO WECT-P425NTYPT 3R ENCLOSUREEXISTING 20A CL20METER 3-PHASE,4-W, 208V R FUSES Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES ELECTRICALDIAGRAM DC System Size (Watts)AC System Size (Watts)Total Module CountPhotovoltaic System288002500072NOTE: UTILITY AC DISCONNECT TO BE INSTALLEDWITHIN 10FT FROM UTILITY METER.Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)DescriptionInverter Output (PV Wire)EGC (Bare Copper Ground)Inverter Output (THWN-2)EGC (THWN-2)Inverter Output (THWN)EGC (THWN)Wire Gauge# of Conductors/ColorConduit TypeConduit SizeTag #6 AWG (AL)8(4L1,4L2,4L3), 4(2L1,2L2,2L3)1 BARE1 (GRN)4(L1, L2, L3, N)1 (GRN)Free AirFree AirPVCSCH 80 PVCN/AN/A1"1" 1, 1A1, 1A2, 2A2, 2A3312 AWG6 AWGSCH 80 PVC12 AWG12 AWG1/0 AWG (AL)2" 8(4L1,4L2,4L3), 4(2L1,2L2,2L3)PVC NOTE :1.24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDEDFOR ALL UTILITY EQUIPMENT.2.UTILITY AC DISCONNECT SHOULD BE LOCATED TOGETHER INA READILY ACCESSIBLE LOCATION WITHIN 10’ OF THE MAINSERVICE METER.PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C [208V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA25KTL-DO/US-208MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER45 KWNOMINAL AC VOLTAGE208 VOLTSMAX. AC CURRENT69.5 AMPSAC POWER25000 W2" REVISION DATE: SEP, 27, 2025REVISION DATE: SEP, 27, 2025 REVISION DATE:SEP, 27, 2025REVISION DATE: OCT, 16, 2025REVISION DATE: NOV, 12, 2025 NOTE:LOAD-SIDE TAPS ARE ONLY ALLOWABLE INSIDE TRANSOCKET IFTHEY ARE LANDED ON THE TRANSOCKET’S LOAD SIDE BUS; SPLICINGONTO THE EXISTING SERVICE ENTRANCE CONDUCTORS IS NOTACCEPTABLE FOR THIS PURPOSE.REVISION DATE: NOV, 12, 2025 Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 WIRECALCS Rooftop conductor ampacities designed in compliance with art. 690.8,Tables 310.15(B)(16), 310.15(B)(2)(a). Location specific temperatureobtained from ASHRAE 2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP-24°C32°C CONDUIT HEIGHT7/8" CONDUCTOR TEMPERATURE RATE (ON ROOF)90°C·Designed according to and all code citations are relevant to the 2017 National Electrical Code.·Tag 2-Use 96% temperature derate for conditions of use (On roof)·Tag 3 - Use 96% temperature derate for conditions of use (adjusted ambient)·System grounding & bonding designed in compliance with 690.47(C)3 and 250.64(E)·Equipment shall be listed, tested, and marked to withstand the available short circuit currentELECTRICAL NOTES Conductor Calculations NUMBER OF CURRENTCARRYING CONDUCTORS INCONDUIT4-67-910-20PERCENT OF VALUES.80.70.50 CONDUCTOR TEMPERATURE RATE (OFF ROOF)75°CTEMP 0.5°54°CTHIS PANEL IS FED BY MULTIPLE SOURCES (UTILITYAND SOLAR)AC OUTPUT CURRENT ACCORDING TO ART. 690.8(B)(1)NOMINAL AC VOLTAGE208V69.5A OCPD Calculations[208V, 3 PHASE] INVERTER SPECIFICATIONSMANUFACTURERCPS SCA25KTL-DO/US-208MAX. DC VOLT RATING1000 VOLTSMAX. PV POWER45 KWNOMINAL AC VOLTAGE208 VOLTSMAX. AC CURRENT69.5 AMPSAC POWER25000 W Breakers sized according to continuous duty output current.Inverter Output Current X (1.25[art. 690.8(A)]) X (139 Max AC current inverter)Inverter #1 = Output Current w/ continuous duty = 69.5A <= 90A Breakersystem output current w/ continuous duty = 86.88 <= 90A (System OCPD)Wire gauge calculated from code art. 310.15(B)(16) with ambient temperature calculations from art. 310.15(B)(2)(a).For "On Roof" conductors we use the 90°C column ampacity, the relevant ambient temperature adjustment, and racewayfill adjustments from 310.15(B)(16). Conduit shall be installed at least 7/8" above the roof surface.For "Off Roof" conductors we use the 75°C column ampacity, or the 75°C column ampacity with the relevant ambienttemperature and raceway fill adjustments, whichever is less.The rating of the conductor after adjustments MUST begreater than, or equal to, the continuous duty output current.Calculation Example - Wire Rating x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous DutyOutput Current(Tag 2 On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.7 (8 Conductors) = 20.16A > 14.15A (Tag 2A On Roof):12 gauge wire rated for 30 A, 30 A x 0.96 x 0.8 (4 Conductors) = 23.04A > 14.15A (Tag 3 Off Roof):1/0 gauge AL wire rated for 120A , 120A x 0.94 x 0.8 = 90.24A > 86.88A (System Output Current) PV MODULE RATING @ STCMANUFACTURERWAAREE ARKA SERIES WSMDI-400 [400W]MAX. POWER-POINT CURRENT (IMP)10.54 AMPSMAX. POWER-POINT VOLTAGE (VMP) 38.0 VOLTSOPEN-CIRCUIT VOLTAGE (VOC) 45.22 VOLTSSHORT-CIRCUIT CURRENT (ISC)11.32 AMPSNOM. MAX. POWER AT STC (PMAX)400 WATTSMAX. SYSTEM VOLTAGE1500VVOC TEMPERATURE COEFFICIENT -0.285 %/°C Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 WARNINGLABELS LABEL LOCATION: RSD INITIATION DEVICE, UTILITY AC DISCONNECTPER CODE: NEC 690.56(C)(2) ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, UTILITY ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7) LABEL LOCATION: UTILITY AC DISCONNECTPER CODE: NEC 690.13(B) LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C) ! LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: UTILITY AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2) DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)! PHOTOVOLTAIC POWER SOURCEPHOTOVOLTAIC SYSTEM UTILITY AC DISCONNECTRATED AC OUTPUT CURRENT: 69.50 A NOMINAL OPERATING AC VOLTAGE: 208 V TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMPHOTOVOLTAIC UTILITYAC DISCONNECT Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address E 1.4 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 PLACARDServiced by Wolf River ElectricContact: (763) 229-6662 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATED AS SHOWNCAUTION ! MULTIPLE SOURCES OF POWERN9848 S 57TH STMAIN SERVICE PANEL (480V)CL 20 METER (480V) UTILITY AC DISCONNECT (480V)INVERTER (480V)CT CABINET (480V)AC DISCONNECT (480V) INVERTER (208V)AC DISCONNECT (208V)MAIN SERVICE PANEL(208V)CL 20 METER(208V) UTILITY AC DISCONNECT (208V)CTCABINET(208V)FUSEDDISCONNECT(208V) Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.1 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MODULE SPECSHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.2 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 INVERTER SPECSHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.3 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 CERTIFICATE OFCOMPLIANCE Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.4 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 SPD SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.5 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 MOUNTING DETAIL SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.6 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ACD SPEC SHEET Sheet NameSheet SizeSheet NumberPALERIA BROTHERS COMMERCIAL ARCH D24" X 36" Signature with Seal Project Name &Address D1.7 DESIGNED BY:TRIVENT CAD SOLUTION RevDateDescriptionREVISIONS WOLF RIVER ELECTRIC101 ISANTI PARKWAY NE, SUITE GISANTI, MN 55040ELECTRICAL CONTRACTOR: 1522577EXPIRATION DATE: 6/30/2028CONTACT: (763) 229-6662contact@wolfriverelectric.com9848 S 57TH ST, FRANKLIN, WI 53132AHJ: CITY OF FRANKLINUTILITY: WE ENERGIES 07CAD 8OCT.16,202508CAD 9OCT.29,202509CAD 10NOV.12,202510CAD 11DEC.03,2025 ACD SPEC SHEET Requested By: John Regetz Email: jregetz@franklinwi.gov Work Phone: (414) 427-7566 Salesperson: Dylan Braun NO. Product Summary QTY UNIT PRICE UNIT PRICE AMOUNT 1 Metal Letters for Monument 1 $11,636.60 $11,636.60 $11,636.60 1.1 Dimensional Letters - Dimensional letters Text: Metal Letters to Be Stud Mounted on Existing Monument - 120 SF Copy : Logo Welcome To Franklin Material: 1/4 " thick painted brushed aluminum Colors: Pantone 294 c, 360 c, 2995 c, 7408 c ** for payment with credit card there will be 3% fee applied to the final balance ** 1.2 Graphic Design Fee - Artwork 2 Install 1 $885.00 $885.00 $885.00 2.1 Installation - 2 person crew Subtotal: $12,521.60 Taxes: $738.77 Grand Total: $13,260.37 Deposit Required: $6,630.19 Bill To: City of Franklin 9229 W Loomis Road Franklin, WI 53132 US Installed: City of Franklin corner of 27th & Drexel Franklin, WI 53555 US DESCRIPTION: Option 2 - Monument Refresh ESTIMATE EST-17517 PO Number: Payment Terms: Cash Customer First Impressions, Great Results www.innovative-signs.com 21700 Doral Rd Waukesha, WI 53186 (262) 432-1330 Created Date: 9/24/2026 Please Note: This estimate is a preliminary approximation and is not a guaranteed final price. It is based on information provided by the client regarding project requirements. Due to the volatility of the materials market, prices are subject to change. The actual cost may be adjusted once all project details are finalized and negotiations are complete. Any changes in cost will be communicated to the client prior to implementation. Generated On: 9/25/2026 9:28 AM Page 1 of 2 30.6 in 59.8 in 14.4 in 119.98 sqft Date 9/24/2026 Order # EST - 17517 Customer City Of Franklin Ashlee K. Paint - Finish Specifications Designer Dylan B. Project Manager Pantone 294c Pantone 360c Pantone 2995c Pantone 7408c www.Innovative-Signs.com - 1/4” Painted metal logo - Stud mounted 72.26 in 40.8 in 239.1 in COMPANY NAME: City of Franklin DOLLAR AMOUNT: Multiple Options ESTIMATE #: 19120 SITE ADDRESS: W Drexel Ave & S 27th St, Franklin, WI 53132 September 24, 2026 Page 1 of 2 CONTRACT JOB DESCRIPTION: Letters for Existing Monument Option #1: ‘Welcome to Franklin, Celebrating Quality of Life, Logo’ Fabricate and install (1) set nonlit 1/4'' thick aluminum FCO letters and logo ''WELCOME TO FRANKLIN CELEBRATING QUALITY OF LIFE + LOGO'' Overall size approximately 62''H x 200''W Will mount to existing Stone Monument Wall Includes removal of existing nonlit Northwestern Mutual letters $10,740.00 Option #2: ‘Welcome to Franklin, Logo’ Fabricate and install (1) set nonlit 1/4'' thick aluminum FCO letters and logo ''WELCOME TO FRANKLIN + LOGO'' Overall size approximately 56''H x 181''W Will mount to existing Stone Monument Wall Includes removal of existing nonlit Northwestern Mutual letters $8,025.00 Site Survey Confirming access, mounting methods, proposed sizes, and colors. $375.00 Permit Procurement Standard permit application paperwork and submittal. If the municipality requires a board meeting for review, attendance is billed at $75/hr. City permit fees billed at cost on final invoice. $375.00 This contract will expire in 30 days from the date listed below if not executed before. Payment terms: Down payment of 50%, Balance due Net 15 Days from installation Date. Permits are not included in this contract and will be added to final invoice as they apply to actual cost & time to procure. Any alterations or deviation from above specifications involving extra cost will become an extra charge over and above the quoted price. I the customer understand and agree that electrical feed and final hook up may include extra charges and is my complete responsibility. Included in this proposal are the costs agreed to by the parties, these costs have been calculated assuming that no unusual or unstable subsurface condition exists or are encountered during construction. If unusual or unstable soil conditions exist or are encountered, the cost of additional foundation work and material will be treated as an extra cost to be added to the above total. Customer ag rees to pay for extra foundation work at the following rates: Materials at cost plus 15%; labor at the rate of $25. 00 per man per hour; soils engineering expert at the rate charged by the soils engineering expert. Customer agrees to be solely responsible for all costs related to unusual or unstable soils conditions even where those conditions have been previously discl osed to Sign Effectz. If the parties have agreed to incorporate or use an existing foundation, Customer agrees any costs incurred as a result of the inadequacy or failure of the existing foundation will be an extra which customer agrees to pay pursuant to the above rate schedule. Payment of all extra costs incurred under this parag raph is COMPANY NAME: City of Franklin DOLLAR AMOUNT: Multiple Options ESTIMATE #: 19120 SITE ADDRESS: W Drexel Ave & S 27th St, Franklin, WI 53132 September 24, 2026 Page 2 of 2 CONTRACT due at the time the extra work billed. Customer shall be solely responsible for all electric service, phone lines and service hook ups of electrical and phone. Payment of the contract price in full is due on delivery regardless of the status of the phone and electric utility service at the sit e. Sign Effectz retains ownership of all sign materials until final payment is made. In the event the Customer does not make all payments required under this contract, at the times required, Customer agrees and hereby gives Sign Effectz permission to enter up on Customer’s property to remove the sign at a time convenient to Sign Effectz Inc., and agrees that the deposit shall constitute liquidated damages to Sign Effectz, because the work is custom work, and the salvage value of the sign is minimal. C ustomer fu rther agrees that any damage to the site incidental to the removal shall be borne by Customer. Any terms in this contract / proposal which are inconsistent with the terms of a contract which this contact / proposal is incorporated into shall govern the inconsistent terms in the incorporating contract and the inconsistent terms of the incorporating contract shall be held for naught. If any of the terms of this contract / proposal are inconsistent with any other contract between parties, the terms of this contract shall govern and the inconsistent terms in the other contact shall be held for naught. Unless otherwise stated in this proposal any signed document transmitted by facsim ile machine (fax) shall be treated in all manner and respects as an original document and the signature of any Party upon a document transmitted by fax shall be considered a n orig inal signature. Any identical copy of this agreement shall be treated in all manners and respects as an original document and the signature of a party on an identical copy shall be considered an original signature. Warranty on parts and labor is 1 year from completion date and will be null and void if there is evidence of the sign being tampered with or worked on by anyone else other than Sign Effectz Inc. Contract Acceptance: The listed prices specifications and conditions are satisfactory and are hereby accepted. Sign E ffectz is hereby authorized to do work as specified. Payment will be made as outlined herein. My signature below indicates that I have read and understand the terms of this contract. This warranty does not cover loss or damage due to accidents involving the product, acts of criminal nature, other property disasters or acts of nature. This includes but is not limited to improper installation conditions, mishandling, misapplication, faul ty wiring, electrical surges, unauthorized attachments or modifications and improper maintenance. Except for those warranties specifically and expressively set forth above, seller disclaims any and all warranties expressed, implied or statutory, including but not limited to, all warranties of merchantability and fitness for particular purpose. This equipment has been tested and found to comply with the limits for class “A” dig ital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operat ed in a commercial environment. This equipment generates uses and can radiate radio frequency energy and, if not installed and used properly, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likel y to cause harmful interference. In this case, the user is required to correct interference at their expense. Customer Signature _______________________________________________Date__________________ Customer Name (Printed)_______________________________________________________________ Sign Effectz Inc. Rep. ______________________________________________Date_________________ W Drexel Ave & S 27th St, Franklin, WI 53132 9229 W. Loomis Road Franklin, WI. 53132 Updated copy per sales 9/23/26 MRM City of Franklin REV: SIGN TYPE. SHEET SIZE. B 01 AUTHOR: MRM DEPT. CONCEPT REV. 01 02 03 04 05 06 BILLING ADDRESS: PROJECT ADDRESS: DESCRIPTION DATE INIT 07 08 10 09 PROJECT NOTES: Copyright © 2026 Sign Effectz Inc. All Rights Reserved CUSTOMER: “Welcome to Franklin” non-lit FCO PROJECT: SCOPE OF WORK: ACCT. MGR. ZK DATE ISSUED: 9/14/26 FCO 1- CONCEPT DRAWING NO: 1 45299526C 1.1_ SCALE: 1/2” = 1' - 0" QUOTE: SHEET NO: Remove existing FCO, from monument signage. Install new non-lit FCO in its place. 18877 OPTION 1: LOGO WITH TAGLINE OPTION 2: LOGO WITHOUT TAGLINE RENDERED VIEW FROM WI-241 FACING WEST RENDERED VIEW FROM WI-241 FACING WEST DIMENSIONS BASED ON ORIGINAL MONUMENT PRODUCTION ARTWORK: SURVEY REQUIRED Welcome to Welcome to W Drexel Ave & S 27th St, Franklin, WI 53132 9229 W. Loomis Road Franklin, WI. 53132 City of Franklin REV: SIGN TYPE. SHEET SIZE. B 00 AUTHOR: MRM DEPT. CONCEPT REV. 01 02 03 04 05 06 BILLING ADDRESS: PROJECT ADDRESS: DESCRIPTION DATE INIT 07 08 10 09 PROJECT NOTES: Copyright © 2026 Sign Effectz Inc. All Rights Reserved CUSTOMER: “Welcome to Franklin” non-lit FCO PROJECT: SCOPE OF WORK: ACCT. MGR. ZK DATE ISSUED: 9/14/26 FCO 1- CONCEPT DRAWING NO: 2 45299526C 1.1_ SCALE: 1/2” = 1' - 0" QUOTE: SHEET NO: Remove existing FCO, from monument signage. Install new non-lit FCO in its place. 18877 EXISTING NON-LIT MONUMENT - NORTH WEST ELEVATION 1/8" =1 ' - 0" SCALE 1 2 29'-4 3/4" 3'-7 1/4" 41'-1 3/8" Approximate location of existing spotlights Grade 3'-6 1/2" Space for previous landscaping/foliage EXISTING NON-LIT MONUMENT - SITE PLAN 1/8" =1 ' - 0" SCALE 2 2 SOIL PLANTING BED RETAINING WALL PAVED FOOT PATH CURVE HAS APPROX. RADIUS OF 74' APPROX. ARCH LENGTH OF WALL IS 41'6" 41'-1" Approximate location of existing spotlights DIMENSIONS BASED ON ORIGINAL MONUMENT PRODUCTION ARTWORK: SURVEY REQUIRED W Drexel Ave & S 27th St, Franklin, WI 53132 9229 W. Loomis Road Franklin, WI. 53132 Updated copy per sales 9/23/26 MRM City of Franklin REV: SIGN TYPE. SHEET SIZE. B 01 AUTHOR: MRM DEPT. CONCEPT REV. 01 02 03 04 05 06 BILLING ADDRESS: PROJECT ADDRESS: DESCRIPTION DATE INIT 07 08 10 09 PROJECT NOTES: Copyright © 2026 Sign Effectz Inc. All Rights Reserved CUSTOMER: “Welcome to Franklin” non-lit FCO PROJECT: SCOPE OF WORK: ACCT. MGR. ZK DATE ISSUED: 9/14/26 FCO 1- CONCEPT DRAWING NO: 3 45299526C 1.1_ SCALE: 1/2” = 1' - 0" QUOTE: SHEET NO: Remove existing FCO, from monument signage. Install new non-lit FCO in its place. 18877 OPTION 1 PROPOSED REFACE - NORTH WEST ELEVATION 1/8" =1 ' - 0" SCALE 1 3 41'-1 3/8" Approximate location of existing spotlights Grade No existing landscaping/foliage 200" Welcome to 2 4 62 3/4" OPTION 2 PROPOSED REFACE - NORTH WEST ELEVATION 1/8" =1 ' - 0" SCALE 1 3 41'-1 3/8" Approximate location of existing spotlights Grade No existing landscaping/foliage 181 3/8" Welcome to 2 5 56" DIMENSIONS BASED ON ORIGINAL MONUMENT PRODUCTION ARTWORK: SURVEY REQUIRED W Drexel Ave & S 27th St, Franklin, WI 53132 9229 W. Loomis Road Franklin, WI. 53132 Updated copy per sales and color schedule 9/23/26 MRM City of Franklin REV: SIGN TYPE. SHEET SIZE. B 01 AUTHOR: MRM DEPT. CONCEPT REV. 01 02 03 04 05 06 BILLING ADDRESS: PROJECT ADDRESS: DESCRIPTION DATE INIT 07 08 10 09 PROJECT NOTES: Copyright © 2026 Sign Effectz Inc. All Rights Reserved CUSTOMER: “Welcome to Franklin” non-lit FCO PROJECT: SCOPE OF WORK: ACCT. MGR. ZK DATE ISSUED: 9/14/26 FCO 1- CONCEPT DRAWING NO: 4 45299526C 1.1_ SCALE: AS NOTED QUOTE: SHEET NO: Remove existing FCO, from monument signage. Install new non-lit FCO in its place. 18877 Welcome to OPTION 1 PROPOSED ALUM FCO REFACE 1/2" =1 ' - 0" SCALE 2 4 27 1/4" 10" 60 5/8" 200" 8'-0" Approximate location of existing spotlights [P-3] [P-4] [P-5] [P-2] [P-1] [P-6] [P-7] [P-8] [P-4] 56" DIMENSIONS BASED ON ORIGINAL MONUMENT PRODUCTION ARTWORK: SURVEY REQUIRED 1 4 SECTION DETAIL - SIDE TYPICAL 1-1/2" =1 ' - 0" SCALE 1 4 1/4" ALUMINUM FCO PAINTED ON ALL SIDES STUD MOUNTED ~1" FROM IRREGULAR STONE SURFACE 8 3/4" 12" 62 3/4" [P-4] PTM PMS 2995C “LIGHT BLUE”, SATIN - [P-5] PTM PMS 7408C “YELLOW”, SATIN - COLOR SCHEDULE: [P-3] PTM PMS 360C “GREEN”, SATIN - [P-6] - “GREEN SHADOW”, SATIN TBD [P-7] - MP PTM “LIGHT BLUE SHADOW”, SATIN TBD [P-8] - MP PTM “YELLOW SHADOW”, SATIN TBD LogoCopy [P-4] SAME AS LOGO COLOR [P-2] MP BLACK, SATIN - [P-1] PTM PMS 294 “DARK BLUE”, SATIN - Font for “Welcome to”: Roboto Condensed Bold Italic W Drexel Ave & S 27th St, Franklin, WI 53132 9229 W. Loomis Road Franklin, WI. 53132 Updated copy per sales and color schedule 9/23/26 MRM City of Franklin REV: SIGN TYPE. SHEET SIZE. B 01 AUTHOR: MRM DEPT. CONCEPT REV. 01 02 03 04 05 06 BILLING ADDRESS: PROJECT ADDRESS: DESCRIPTION DATE INIT 07 08 10 09 PROJECT NOTES: Copyright © 2026 Sign Effectz Inc. All Rights Reserved CUSTOMER: “Welcome to Franklin” non-lit FCO PROJECT: SCOPE OF WORK: ACCT. MGR. ZK DATE ISSUED: 9/14/26 FCO 1- CONCEPT DRAWING NO: 5 45299526C 1.1_ SCALE: AS NOTED QUOTE: SHEET NO: Remove existing FCO, from monument signage. Install new non-lit FCO in its place. 18877 Welcome to OPTION 2 PROPOSED ALUM FCO REFACE 1/2" =1 ' - 0" SCALE 2 5 27 1/4" 10" 60 5/8" 181 3/8" 8'-0" Approximate location of existing spotlights [P-3] [P-4] [P-5] [P-2] [P-1] [P-6] [P-7] [P-8] 56" DIMENSIONS BASED ON ORIGINAL MONUMENT PRODUCTION ARTWORK: SURVEY REQUIRED 1 5 [P-4] PTM PMS 2995C “LIGHT BLUE”, SATIN - [P-5] PTM PMS 7408C “YELLOW”, SATIN - COLOR SCHEDULE: [P-3] PTM PMS 360C “GREEN”, SATIN - [P-6] - “GREEN SHADOW”, SATIN TBD [P-7] - MP PTM “LIGHT BLUE SHADOW”, SATIN TBD [P-8] - MP PTM “YELLOW SHADOW”, SATIN TBD LogoCopy [P-4] SAME AS LOGO COLOR [P-2] MP BLACK, SATIN - [P-1] PTM PMS 294 “DARK BLUE”, SATIN - SECTION DETAIL - SIDE TYPICAL 1-1/2" =1 ' - 0" SCALE 1 5 1/4" ALUMINUM FCO PAINTED ON ALL SIDES STUD MOUNTED ~1" FROM IRREGULAR STONE SURFACE Font for “Welcome to”: Roboto Condensed Bold Italic 16" Requested By: John Regetz Email: JRegetz@franklinwi.gov Salesperson: House Signarama NO. Product Summary QTY UNIT PRICE UNIT PRICE AMOUNT 1 Monument Sign Lettering - Without Tagline 1 $11,590.00 $11,590.00 $11,590.00 "Welcome To": • 1in D Fabricated aluminum • Pin mounted • Custom painted • 86.9in W x 12.7in H Flags: • 1.5in D Fabricated aluminum • Pin mounted • Custom painted • Green: 40.4in W x 16.1in H • Blue: 28.1in W x 15.1in H • Yellow: 25.3in W x 20.8in H "Franklin": • 1.5in D Fabricated aluminum • Pin mounted • Custom painted • 122.6in W x 26.3in H "WISCONSIN": • 1in D Fabricated aluminum • Pin mounted • Custom painted • 118.8in W x 7.7in H Bill To: City of Franklin, WI 6591 S. Whitnall Edge Road Franklin, WI 53132 US Installed: City of Franklin, WI NW Corner of S 27th & Drexel Franklin, WI 53132 US DESCRIPTION: Monument Sign Lettering ESTIMATE EST-31431 PO Number: Payment Terms: Cash Customer https://www.signarama.com/wi-franklinwi.com 10700 West Venture Drive Unit F Franklin, WI 53132 (414) 235-3353 Created Date: 9/22/2026 Generated On: 9/22/2026 2:10 PM Page 1 of 3 • Price includes installation • Price does not include permitting, if required 2 Monument Sign Lettering - With Tagline 1 $12,040.00 $12,040.00 $12,040.00 "Welcome To": • 1in D Fabricated aluminum • Pin mounted • Custom painted • 86.9in W x 12.7in H Flags: • 1.5in D Fabricated aluminum • Pin mounted • Custom painted • Green: 32.8in W x 13in H • Blue: 22.8in W x 12.3in H • Yellow: 20.6in W x 17in H "Franklin": • 1.5in D Fabricated aluminum • Pin mounted • Custom painted • 122.6in W x 26.3in H "WISCONSIN": • 1in D Fabricated aluminum • Pin mounted • Custom painted • 118.8in W x 7.7in H "Celebrating Quality of Life": • 1in D Fabricated aluminum • Pin mounted • Custom painted • 118.8in W x 7.7in H • Price includes installation • Price does not include permitting, if required 3 Permitting 1 $0.00 $0.00 $0.00 • Signarama is assuming that permitting is not needed, however, if permitting is needed, we can gladly take care of that as well. Permitting costs would be $200 + the fees from the City. This estimate is valid for 30 days from the date of issue. Unless credit terms have been approved a 50% deposit is required to begin design or production for all projects over $500 . All projects under $500 require full payment prior to starting design or production. Final payment is due upon completion of project. If invoice goes 30 days past due, fees will begin to accrue at a rate of 1.5% of the total project cost per month. Generated On: 9/22/2026 2:10 PM Page 2 of 3 Thank you for choosing Signarama. Unless Otherwise Specified: Any tangible or intangible work generated per this document remain the property of Signarama until the order is paid in full. The order may not be cancelled after customer approval. In case of any deviations from the proof, we will redo the work as quickly as possible without charge. If you approve or imply approval of the proof, you are responsible for correctness of copy. Our liability is limited to the replacement of work included in this document, we are not responsible for any subsequent damages, consequential damages, or otherwise. We will hold completed and or customer supplied items for 60 days after which we will discard it; you will be billed and held responsible for full payment. We're a local small business who thrive because of customers like you. Please support us by making timely payments. Signarama is independently owned and operated Signature: Date: Generated On: 9/22/2026 2:10 PM Page 3 of 3

Source: City of Franklin website. First collected Oct 16, 2026.