Building Board — Agenda
Village of Fox Point · Milwaukee County · Building Board · meeting of Oct 8, 2025 · Agendas
Open the original document More from Village of Fox Point
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
PLEASE NOTE: Upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through sign langu age
interpreters or other auxiliary aids. For additional information or to request these services, contact the Village Clerk at 4 14-351-8900. It is
possible that members of, and possibly a quorum of members of, other governmental bodies of the municipality may be in attend ance at the
above stated meeting to gather information; no action will be taken by any governmental body at the ab ove stated meeting other than the
governmental body specifically referred to above in this notice.
NOTICE OF MEETING
VILLAGE OF FOX POINT
BUILDING BOARD
NOTE: THIS MEETING WILL BE HELD Wednesday
VIRTUALLY ONLY VIA WEBINAR.
NO IN-PERSON ATTENDANCE HELD.
October 8, 2025
5:00 P.M.
Join Zoom Meeting
https://us02web.zoom.us/j/83877661472
Meeting ID: 838 7766 1472
Dial by your location: 312.626.6799
AGENDA
1. Roll call of board members and quorum confirmation.
2. Discussion, corrections, and approval of the minutes of the September 10, 2025 Building
Board meeting.
3. Mike Bork, 7457 N Mohawk Rd, proposed windows and siding.
4. Matthew Wuest, 8323 N Santa Monica Blvd, proposed accessory structure.
5. Annie Blair, 257 W Suburban Dr, proposed addition.
6. Adjourn.
Posted and Published: October 1, 2025
VILLAGE OF FOX POINT
BUILDING BOARD MINUTES
A meeting of the Building Board was held via Zoom, on Wednesday, September 10, 2025, at 5:00 pm. Those present included:
Justin Racinowski
William Feldman
Sharon Celek-Absent
Lucille Sells
Pat Algiers
Michael Rakow
Notice of the meeting was provided to the North Shore Now and to all others as required by State open meeting laws and posted on the
official bulletin boards.
MINUTES
Motion was made by Pat Algiers to approve the minutes of August 13. Motion was seconded by William Feldman. Motion Caried.
AGENDA
1. Pieter Lens, 340 E Daphne Rd, proposed office addition. It was the consensus of the Building Board to approve as
submitted.
2. Chad Wenzel, 7539 N Bell Rd, proposed pergola. It was the consensus of the Building Board to approve as submitted.
ADJOURN
Motion to adjourn Building Board was made by William Feldman. Motion seconded by Pat Algiers. Motion Caried. Building Board
adjourned at 5:12 pm.
Respectfully Submitted,
Michael Rakow
Building Inspector
Village of Fox Point
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
4'-7"
N 06°54'40" E 166.20'
WEST 120.00'
N 27°03'20" E 187.14'
EXISTING
GARAGE
REMOVE
SHED
EXISTING CONC. DRIVE
EXISTING
BRICK
WALKWAY
EXISTING METAL FENCE RECONFIGURE FENCE
AT ACCESSORY
BUILDING
EXISTING LIMESTONE STEP
EXISTING BRICK PATIO
EXISTING METAL FENCE
10 FOOT SETBACK
10 FOOT SETBACK
10 FOOT SETBACK
EXISTING
RESIDENCE
EXISTING BRICK WALKWAY
LIMESTONE STEPPERS (24x72)
PAVER PATIO w/
BRICK EDGING
EXISTING LANDSCAPE
BLOCK SITE WALL w/
LIMESTONE COPING
BUILDING AREA
CALCULATIONS
C RESIDENCE DISTRICT
LOT SIZE 14,506 SF
EXISTING RESIDENCE FOOTPRINT 2147 SF
PROPOSED ACCESSORY BUILDING FOOTPRINT 740 SF
TOTAL EXISTING & PROPOSED BUILDINGS 2887 SF
TOTAL OPEN AREA (10,500 SF MIN) 11,619 SF
MAX ACCESSORY BUILDING SIZE (15% OF LOT EACH) 2176 SF
6'-2"1'-0"
6"
1'-0"
740 SF
PROPOSED ACCESSORY
BUILDING
SCALE: 1" = 10'1Site Plan
C1
Title Page
ACCESSORY BUILDING ADDITION
8323 N SANTA MONICA BLVD
FOX POINT, WI
NORTH
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
1Front / North Elevation 2Front / North Elevation 3West Elevation
4Southwest View 5South Elevation 6Southeast View
C2
Existing Photos
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
23'-10"
4"8" 8"4"
31'-0"
4"8" 8"4"
3A3
2A3
1A3
4A3
SCALE: 1/4" = 1'-0"1Foundation Plan
NORTH
A0
Foundation Plan
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction30'-4"
17'-4" 5'-4" 10"
18'-0"
16'-3"
5'-5"
6" 9'-93/8" 9'-93/8" 9'-93/8" 6"
1'-4"
1'-4"
EQ EQ
3'-91/4"
EQ EQ
8'-8" 8'-8"
3A3
2A3
1A3
4A3
GOLF BAG &
OTTOMAN
STOAGE
OVERHEAD PROJECTOR
TEE LOCATION
SCREEN
BEV CTR
DN
3R
TURF FLOORING
FLOORING
TBD
DN 1R
REMOVABLE CUSTOM LIGHT /
SOUND PROTECTION PANEL
AT INSIDE OF WINDOW, TYP.
RESIDENTIAL SOUND
PANELS ON WALLS &
CEILING
VIEWING
GOLF
BLACK OUT
SHADES
55"TV
GOLF BAG STOAGE w/
COMPUTER ABOVE, CONFIRM
HEIGHT & REVISED LOCATION
8-1 /2 FT
COUCH
10 FT CEIL ING
DRINKS NICHE
DRINKS NICHE
HOOKS
1/ 2 IN 12
PAVER PATIO INFILL
BRICK PATIO
EDGING
36x80 EXTERIOR
DOOR 30x34 SASH SET
FIXED WINDOW
36x60 DOUBLE
HUNG WINDOW
(2)34x60 DOUBLE HUNG
WINDOWS w/ (2)24x1 7 SASH
SET FIXED TRANSOMS
SCALE: 1/4" = 1'-0"1First Floor Plan
A1
First Floor Plan
NORTH
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
3A3
2A3
1A3
4A3
21/2"
11/2"
41/2"
11/2"
12 IN 12
12 IN 12
4 IN 12
OUTSIDE OF
SHEATHING
CONTINUOUS
RIDGE VENT
FLASHING AT
CHANGE OF
PLANE
GUTTER
SCALE: 1/4" = 1'-0"1Roof Plan
A2
Roof Plan
NORTH
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 26, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
18'-7"
6" 91/2"
1'-0"
FIRST FLOOR TOP OF SLAB
10 0 '- 0 "
GOLF AREA TOP OF SLAB
98'-8"
TOP OF WALL
10 8 '- 8 1/ 2 "
TOP OF FOUNDATION
95'-6"
ASPHALT SHINGLE ROOF -
MATCH EXISTING ON
RESIDENCE
GUTTER & DOWNSPOUT
5/4x8 TRIM BOARD
8x8 MITER LOCKED COLUMN
LAP SIDING - MATCH EXISTING
ON RESIDENCE
5/4x6 CORNER BOARDS
ALUM CLAD WOOD WINDOW
ASSEMBLY w/ SHUTTERS, 5/4x4
CASING, SILL, 5/4x6 APRON, &
5/4x6 HEAD CASING
1- 1/ 2 " T L IMEST ONE CA P
BRICK PIER, PATIO EDGING, &
PATIO FACING - BRICK TO
MATCH EXISTING RESIDENCE
POURED CONCRETE
FOUNDATIONS & FOOTINGS
LIGHT FIXTURE
ON 5/4" T
LIGHT BLOCK
12 " W IDE FL OW ER
BOX w/ 2-1/4"H
TRIM ON
BRACKETS
WINDOW / DOOR HEAD
10 6 '- 8 "
FIRST FLOOR TOP OF SLAB
10 0 '- 0 "
GOLF AREA TOP OF SLAB
98'-8"
TOP OF WALL
10 8 '- 8 1/ 2 "
TOP OF FOUNDATION
95'-6"
ASPHALT SHINGLE ROOF -
MATCH EXISTING ON RESIDENCE
GUTTER & DOWNSPOUT
5/4x8 TRIM BOARD
LAP SIDING - MATCH EXISTING
ON RESIDENCE
5/4x6 CORNER BOARDS
BRICK BACE & CAP - BRICK TO
MATCH EXISTING RESIDENCE
POURED CONCRETE
FOUNDATIONS & FOOTINGS
FIRST FLOOR TOP OF SLAB
10 0 '- 0 "
GOLF AREA TOP OF SLAB
98'-8"
TOP OF WALL
10 8 '- 8 1/ 2 "
TOP OF FOUNDATION
95'-6"
ASPHALT SHINGLE ROOF -
MATCH EXISTING ON RESIDENCE
GUTTER & DOWNSPOUT
5/4x8 TRIM BOARD
LAP SIDING - MATCH EXISTING
ON RESIDENCE
5/4x6 CORNER BOARDS
POURED CONCRETE
FOUNDATIONS & FOOTINGS
BRICK BACE & CAP - BRICK TO
MATCH EXISTING RESIDENCE
6"
FIRST FLOOR TOP OF SLAB
10 0 '- 0 "
GOLF AREA TOP OF SLAB
98'-8"
TOP OF FOUNDATION
95'-6"
ASSUMES 2x1 0 ROOF FRAMING
TOP OF WALL
10 8 '- 8 1/ 2 "
WINDOW / DOOR HEAD
10 6 '- 8 "
ASPHALT SHINGLE ROOF -
MATCH EXISTING ON RESIDENCE
GUTTER & DOWNSPOUT
5/4x8 TRIM BOARD
8x8 MITER LOCKED COLUMN
LAP SIDING - MATCH EXISTING
ON RESIDENCE
5/4x6 CORNER BOARDS
ALUM CLAD WOOD WINDOW
ASSEMBLY w/ SHUTTERS, 5/4x4
CASING, SILL, 5/4x6 APRON, &
5/4x8 HEAD CASING & CROWN
1- 1/ 2 " T L IMEST ONE CA P
BRICK PIER, PATIO EDGING, &
PATIO FACING - BRICK TO
MATCH EXISTING RESIDENCE
POURED CONCRETE
FOUNDATIONS & FOOTINGS
SCALE: 1/4" = 1'-0"1North Elevation SCALE: 1/4" = 1'-0"2East Elevation
SCALE: 1/4" = 1'-0"3South Elevation SCALE: 1/4" = 1'-0"4West Elevation
A3
Exterior
Elevations
Drawing Title:
Sheet:
Wuest Accessory Building
Fox Point, WI
Project:
Caution: Do not scale drawings.
These are the property of the
designer and may only be used in
conjunction with this proect.
Sept. 29, 2025Review Set
Issue:
These drawings and design there in are
the exclusive property of CNChambliss
Architecture, llc
Notice:
© Copyright 2025 CNChambliss
Architecture llc. All rights reserved. This
document, ideas and design
incorporated herein are the property
of CNChambliss Architecture llc. and are
not to be used whole or in part
without the written consent of
CNChambliss Architecture llc.
Not for Construction
3A3
2A3
1A3
4A3
2
A2
2
A2
21/2"
11/2"
41/2"
11/2"
12 IN 12
12 IN 12
4 IN 12
OUTSIDE OF
SHEATHING
CONTINUOUS
RIDGE VENT
FLASHING AT
CHANGE OF
PLANE
GUTTER
FIRST FLOOR TOP OF SLAB
10 0 '- 0 "
GOLF AREA TOP OF SLAB
98'-8"
TOP OF FOUNDATION
95'-6"
TOP OF WALL
10 8 '- 8 1/ 2 "
WINDOW / DOOR HEAD
10 6 '- 8 "
BRICK & PAVER PATIO FACING -
CONFIRM THICKNESS
FOUNDATION DRAINAGE
2" PROTECTION BOARD
CONTINUOUS POURED CONCRETE
STRIP FOOTING
POURED CONCRETE
FOUNDATION WALL
GRADE
BRICK WALL FACING - GROUT SOLID
SLOPED CONCRETE SLAB
LAP SIDING ON AIR/WATER BARRIER ON
1/ 2 " PL Y W OOD S HE A T HING
2x6 P.T. SILL PLATE ON SILL
SEALER w/ ANCHOR BOLTS @
4'-0" - SEE STRUCTURAL
1/ 2 " GY P. BD. ON V A POR
BARRIER
WINDOW HEADER - SEE
STUCTURAL
CONCRETE SLAB OVER VAPOR
BARRIER ON 4" INSULATION ON
6" MIN COMPACTED GRAVEL
BATT INSULATION
WINDOW ASSEMBLY
2x6 TOP PLATE
CEILING FRAMING - SEE STRUCTURE
5/8" GYP BD @ CELING
BLOWN IN INSULATION R-60
LEDGER BOARD & BLOCKING
ASPHALT SHINGLE ROOFING
OVER UNDERLAYMENT OVER
ICE & WEATHER SHIELD, OVER
3/4" ROOF SHEATHING
CONTINUOUS PEAK VENT
BEAM - SEE STRUCTURE
1x TRIM - BUILT UP DECO BEA M
S4S FINISHED LUMBER PORCH FRAMING
S4S FINISHED LUMBER PORCH DECKING
GUTTER
SCALE: 1/4" = 1'-0"1Roof Plan
SCALE: 1/4" = 1'-0"2Building Section
A2
Roof Plan &
Section
NORTH
BLAIR RESIDENCE257 W SUBURBAN DR. | FOX POINT, WI 53217
SHEET INDEX:
PROJECT SITE
PROJECT INFORMATION:
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
T1.0TITLE PAGE
ARCHITECTURAL REVIEW BOARDSEPTEMBER 26, 2025
T 1.0 TITLE SHEETT 1.1 EXISTING EXTERIOR IMAGEST 1.2 EXTERIOR ROOF & PAINT COLOR DESIGN DIRECTIOND 1.0 DEMO & NEW FLOOR PLAN - MAIN & SECOND LEVELA 1.1 DEMO & NEW FLOOR PLAN - GARAGED 2.0 DEMO - EXTERIOR ELEVATIONSD 2.1 DEMO - EXTERIOR ELEVATIONSA 2.0 EXTERIOR ELEVATIONSA 2.1 EXTERIOR ELEVATIONSA 3.0 BUILDING SECTION, DETAILSPROJECTSITE
BUILDING CODE:ZONING:SF OF RESIDENCE FINISHED (LEVEL 1 & 2 +ADDITION. NOT INCLUDING GARAGE OR UNFINISHEDBASEMENT)SF OF REMODEL WORK EXISTING MAIN: EXISTING SECOND LEVEL: SECOND LEVEL PRIMARY SUITE ADDITION: GARAGE:NO. OF STORIES:
WISCONSIN UDCFOX POINT - SINGLEFAMILY2,970 SF (GROSS)1,486 SF1,012 SF 472 SF 484 SF2
EXISTING EXTERIOR - EAST1EXISTING EXTERIOR - SOUTH2EXISTING EXTERIOR - WEST3
EXISTING EXTERIOR - EAST4EXISTING EXTERIOR - WEST5EXISTING EXTERIOR - NORTH6
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
T1.1EXISTING EXTERIORIMAGES
COLOR PALETTE OPTIONS FOR ROOF SHINGLES & SIDING (SHAKE) PAINT COLORS1
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
T1.2 PROPOSED EXTERIORMATERIAL COLORS
10'-7"10'-7"5'-4"10'-6"10'-11"
12'-112"
8'-0"12'-10"24'-4" 21'-8" 10'-6"1'-0"79'-0"21'-6"
15'-112" 312"2'-112" 7'-712"
5'-0"6'-0"5'-0"12'-0"
10'-6"
14'-512"
21'-612"
5'-5"
6'-0"10'-11"12'-6"37'-0"
12'-0"
11'-1"
2'-6"6'-6" 14'-2"9'-0"
16'-912"
10'-112"
2'-0"414" 21'-9"
10'-9"3'-6"10'-9"
9'-1-1/2"B.O. COLLAR TIE9'-7"T.O. COLLAR TIE7'-5-1/4"B.O. RIDGE BOARD FROM T.O. TIE
STAIRS: MAIN LEVEL TO LEVEL 214R @ 7-5/8"
H: 56S: 37
21'-114"
STAIRS: MAIN LEVEL TO GARAGE2R @ 6-1/2"
2D2.0
D2.11D2.12
D2.01
UP DN
REMOVE AND REUSE DOORAT BATHROOM ENTRANCE
GC TO VERIFY IF WALL ISSTRUCTURAL
DRAWING KEY
EXISTING DOOR TO REMAINNEW DOOR, REMOVE EXISTING
C.L. CENTER LINED3.-1EXTERIOR ELEVATION &SECTION TAG
DEMO
DEMO PLAN GENERAL NOTESA.VERIFY ALL EXISTING STRUCTURAL CONDITIONS TO VERIFY WITHSTRUCTURAL DRAWINGS.B.EVALUATE THE CONDITION OF EXTERIOR COMPONENTS, SUCH ASROOF, TIMBERING, WINDOWS, GUTTERS AND MASONRY. SUGGESTREPAIRS, REFINISHING OR REPLACEMENT AS NEEDED.C.SALVAGE ALL EXTERIOR BRICK VENEER IN DEMOLISHED AREASFOR REUSE ON PROJECT.F.PREP FOR NEW FLOORING IN CONSTRUCTION AREA.G.REMOVE EXISTING DOORS IN CONSTRUCTION AREA.H.PRESERVE WOOD FLOORING WHERE POSSIBLE IN CONSTRUCTIONAREA. PREP FOR SANDING & FINISHING. VERIFY WITH ARCHITECT.I.DEMO OR CONSOLIDATE ALL LIGHTING AND ELECTRIC CONDUITON CEILING AND WALLS IN CONSTRUCTION AREA.J.EVALUATE ALL FLOOR DRAINS FOR PROPER DRAINAGE.K.REVIEW AND DEMO EXISTING HVAC DUCTS AS NEEDED INCONSTRUCTION AREA. COORDINATE WITH HVAC CONTRACTOR.EVALUATE EXISTING FURNACE & WATER HEATER FORAPPROPRIATE SIZING. PROVIDE ARCHITECT WITH PROPOSED NEWDUCT LAYOUT TO COORDINATE WITH NEW DESIGN INTENT.L.EVALUATE INSULATION CONDITIONS IN EXISTING EXTERIORWALLS AND ROOF IN CONSTRUCTION AREA. BRING CONDITIONSTO CURRENT ENERGY CODE IF NOT COMPLIANT.M.SALVAGE ALL REMOVED CABINETRY, DOORS AND OTHERINTERIOR ITEMS THAT CAN BE REPURPOSED AT A SECOND HANDBUILDING STORE. VERIFY IF ANY OF THESE ITEMS WILL BEREUSED ON THE PROJECT.
EXISTING WALL / NO WORK
12
KEYED NOTESPREP FOR NEW FLOORING, DEMO EXISTINGREMOVE CEILING FINISH. EVALUATECEILING HEIGHT.3VERIFY ALL EXISTING STRUCTURE
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
D1.0EXISTING / DEMOFLOOR PLANS
1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH
Missing or invalid reference
11'-112"3'-9"4'-012" 3'-3"
8'-7"
4'-9"2'-4"5'-10"6'-10" 2'-6"30'-9"
7'-712"13'-0"18'-0"7'-11"CEILING
6'-9"CEILING
6'-10.5"CEILING6'-6"CEILING
7'-4.5"CEILING
5'-6.5"CEILING4'-0"CEILING
10'-5"
12'-434"
414" 21'-9"
9'-1-1/2"B.O. COLLAR TIE9'-7"T.O. COLLAR TIE7'-5-1/4"B.O. RIDGE BOARD FROM T.O. TIE
21'-114"
2D2.0
D2.11D2.12
D2.01
DN
DRAWING KEY
EXISTING DOOR TO REMAINNEW DOOR, REMOVE EXISTING
C.L. CENTER LINED3.-1EXTERIOR ELEVATION &SECTION TAG
DEMO
DEMO PLAN GENERAL NOTESA.VERIFY ALL EXISTING STRUCTURAL CONDITIONS TO VERIFY WITHSTRUCTURAL DRAWINGS.B.EVALUATE THE CONDITION OF EXTERIOR COMPONENTS, SUCH ASROOF, TIMBERING, WINDOWS, GUTTERS AND MASONRY. SUGGESTREPAIRS, REFINISHING OR REPLACEMENT AS NEEDED.C.SALVAGE ALL EXTERIOR BRICK VENEER IN DEMOLISHED AREASFOR REUSE ON PROJECT.F.PREP FOR NEW FLOORING IN CONSTRUCTION AREA.G.REMOVE EXISTING DOORS IN CONSTRUCTION AREA.H.PRESERVE WOOD FLOORING WHERE POSSIBLE IN CONSTRUCTIONAREA. PREP FOR SANDING & FINISHING. VERIFY WITH ARCHITECT.I.DEMO OR CONSOLIDATE ALL LIGHTING AND ELECTRIC CONDUITON CEILING AND WALLS IN CONSTRUCTION AREA.J.EVALUATE ALL FLOOR DRAINS FOR PROPER DRAINAGE.K.REVIEW AND DEMO EXISTING HVAC DUCTS AS NEEDED INCONSTRUCTION AREA. COORDINATE WITH HVAC CONTRACTOR.EVALUATE EXISTING FURNACE & WATER HEATER FORAPPROPRIATE SIZING. PROVIDE ARCHITECT WITH PROPOSED NEWDUCT LAYOUT TO COORDINATE WITH NEW DESIGN INTENT.L.EVALUATE INSULATION CONDITIONS IN EXISTING EXTERIORWALLS AND ROOF IN CONSTRUCTION AREA. BRING CONDITIONSTO CURRENT ENERGY CODE IF NOT COMPLIANT.M.SALVAGE ALL REMOVED CABINETRY, DOORS AND OTHERINTERIOR ITEMS THAT CAN BE REPURPOSED AT A SECOND HANDBUILDING STORE. VERIFY IF ANY OF THESE ITEMS WILL BEREUSED ON THE PROJECT.
EXISTING WALL / NO WORK
12
KEYED NOTESPREP FOR NEW FLOORING, DEMO EXISTINGREMOVE CEILING FINISH. EVALUATECEILING HEIGHT.3VERIFY ALL EXISTING STRUCTURE
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
D1.1EXISTING / DEMOFLOOR PLANS
1FLOOR PLAN - SECOND LEVEL1/4" = 1'NPLANNORTH
3'-10"
21'-9"
21'-114"
PANTRY
PANTRY
REF
2A2.0
A2.11A2.12
A2.01
A3.01
A3.01
PANTRY
BEDROOM106
FOYER100
15'-612" 4'-212"
LIVING101
DINING102KITCHEN / FAMILY103
MUD104
GARAGE105
BATH106
UP DN
DN GC TO VERIFY IF WALL ISSTRUCTURAL3'-10"8'-4"
3'-0"3'-4"
BANQUETBENCHSEE STRUCTURAL FORGARAGE WALLMODIFICATIONS
SEE STRUCTURAL FORGARAGE WALLMODIFICATIONS
AB
1
3'-4"4'-0"
LINEN106A106B4'-0"
8'-412"
3'-8"
A.THESE GENERAL NOTES APPLY TO THE CONSTRUCTIONDOCUMENTS AND SHALL GOVERN UNLESS NOTED OTHERWISE BYGENERAL NOTES OR KEYNOTES ON SPECIFIC SHEETS.B.NOTIFY DESIGNER PROMPTLY IF INFORMATION SHOWN IN ONECONSTRUCTION DOCUMENT CONFLICTS WITH INFORMATIONSHOWN ON ANOTHER.C.NOTIFY DESIGNER PROMPTLY IF CONSTRUCTION DOCUMENTSARE INCONSISTENT WITH THE CURRENT APPLICABLE CODES ANDREGULATIONS.D.COORDINATE EXACT LOCATIONS OF LIGHT FIXTURES. SPEAKERS,SMOKE DETECTORS, ACCESS PANELS, HVAC DUCTS, DIFFUSERS,REGISTERS, FIRE ALARMS, AND OTHER SUCH CEILING ITEMS WITHMECHANICAL, ELECTRICAL AND OTHER TRADES. NOTIFYARCHITECT PROMPTLY IF ANY LOCATIONS CONFLICT WITHARCHITECTURAL REFLECTED CEILING PLANS.E.HVAC: COORDINATE POSITION OF GRILLES, DUCTS AND / ORCASSETTES WITH DESIGNER FOR PLACEMENT IN RELATION TOLIGHTING, WALL CLADDING, FURNITURE ARRANGEMENTS,CABINETRY, ETC.F.TYPICAL FLOOR PLAN DIMENSIONS ARE SHOWN TO THE FINISHFACE OF WALLS, CABINETRY AND TRIM UNLESS NOTEDOTHERWISE. WHERE A CLEAR DIMENSION OR OPENING ISREQUIRED OR NOTED, MEASURE DIMENSION TO FACE OFPARTITION FINISH.G.REFER TO PLANS, SECTIONS AND ELEVATIONS FOR PLACEMENTAND ALIGNMENTS WITH EXISTING AND NEW DESIGN ELEMENTS.H.PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREASTHAT ARE SCHEDULED TO RECEIVE CERAMIC TILE FINISH AND ATAREAS REQUIRED BY CODE TO RECEIVE IT.I.PROVIDE TILE BACKER BOARD AT WET AREAS THAT ARESCHEDULED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMICTILE FINISH.J.INSTALL BLOCKING OR BACKER MATERIAL FORATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENTDESCRIBED IN THE DOCUMENTS.K.PROVIDE ACOUSTIC INSULATION BETWEEN ALL BEDROOMS,BATHROOMS, LAUNDRY, MECHANICAL ROOMS AND BETWEENFLOOR / LEVELS OF THE HOME. ALL ELEMENTS OF ACOUSTICRATED PARTITIONS SHALL EXTEND TO ROOF OR FLOOR DECKABOVE AND ALL JOINTS AND PENETRATIONS OF ACOUSTIC RATEDPARTITIONS SHALL BE FILLED AND SEALED.L.ALL ROOF & WALL PENETRATIONS & VENTS, SUCH AS STACK VENTPIPES, DRYER VENT TO MATCH THE FINISH COLOR OF ADJACENTSURFACE. VERIFY COLOR WITH ARCHITECT. WHERE POSSIBLECOORDINATE NEW ROOF PENETRATIONS TO EXIT THROUGH NEWCHIMNEY.M.PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THEPARTITIONS TO OTHER PORTIONS OF THE WORK SHALL BE INACCORDANCE WITH MANUFACTURERS' RECOMMENDED DETAILSAND IN COMPLIANCE WITH APPLICABLE TESTING AGENCYREQUIREMENTS.
PROJECT GENERAL NOTES
DRAWING KEY
NEW WALLEXISTING WALL
EXISTING DOOR
NEW DOOR
C.L. CENTER LINE
000X
A3.-1A5.-1
DOOR TAGWALL ASSEMBLYINTERIORELEVATIONSEE A.5 SHEETSEXTERIORELEVATION &SECTION TAGXWINDOW TAG
TYP TYPICAL
INTERIOR PARTITION NOTESA.ALL INTERIOR PARTITIONS SHALL BE TYPE "A1" UNLESS NOTEDOTHERWISE.B.ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALLEXTEND TO ROOF OR FLOOR DECK ABOVE AND ALL JOINTS ANDPENETRATIONS OF ACOUSTIC RATED PARTITIONS SHALL BEFILLED AND SEALED.C.REFER TO "INTERIOR PARTITION TYPE SUBSCRIPT KEY" FORSYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS ORMODIFICATIONS TO BASIC PARTITION TYPES.D.PARTITION REQUIREMENTS SHOWN ARE CONSIDERED MINIMUMSTANDARDS. WHERE CONDITIONS OF THE WORK CAUSEPARTITION(S) TO EXCEED LIMITS RECOMMENDED BYMANUFACTURER, REINFORCE PARTITION(S.)E.INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASEBOARD SHALL CONFORM TO REQUIREMENTS FOR FIRERATINGS AND ACOUSTICAL RATINGS.F.WHERE PARTITIONS AND/OR FURRING MEET, MAINTAIN A FLUSHSURFACE ON THE SIDE WHERE THE FINISH IS STRAIGHT ORCONTINUOUS UNLESS NOTED OTHERWISE.F.SEE GENERAL PROJECT NOTES FOR ADDITIONAL INFORMATION
SERIES - WOOD STUD PARTITION RATING AS NOTEDAXAXWOODX2" SUBSCRIPT (A)ACOUSTICALINSULATIONSUBSCRIPT (WOOD)MATERIAL FINISHSUBSCRIPT (X" OC)WALL FURRINGDEPTH
X3'-6"SUBSCRIPT (X'-X")PARTITION HEIGHTAS NOTED
INTERIOR PARTITION SUBSCRIPT KEYINTERIOR WALL TYPES
ACOUSTICAL BATT INSULATIONAS DENOTED PER SUBSCRIPT ONLY
1/2" GWB, UNO BYINTERIOR WALL FINISH SCHEDULEWOOD STUDS @ 16" OC, UNOINT.
INT.PARTITIONTYPENOTESPARTITIONWIDTH
6-1/2"A2STANDARD 2x4 WOOD STUDINTERIOR PARTITIONA14-1/2"A3EXISTING EXT / INT WALL WITH INTERIORFURRING (SEE PLAN FOR DETAILS)STANDARD 2x6 WOOD STUDINTERIOR PARTITIONEXISTING WALL+2" - 4"
EXTERIOR WALL TYPES
2x6 DORMER & MUDROOM STUD WALL WITHVENTILATED RAIN SCREEN CLADDING
SIDING PER SCHEDULE
WEATHER BARRIER12" WALL SHEATHING
1/2" GWB, WALL FINISH PER SCHEDULE,2X6 STUDS @ 24": O.C., UNO
14"12"512"58" 714"
INT.
EXT.
2
DENSE PACK CELLULOSE INSULATION ORCLOSED CELL SPRAY FOAM (R19MIN.)VAPOR BARRIER IF CELLULOSE OR SIM.
38"RAIN SCREEN NETTING
45 MIN. WOOD STUD WALL58" GYPSUM WALL BOARD
634"234"234" 58"
2x4 WOOD STUDS AT 16" O.C.
58" TYPE X GYPSUM WALL BOARDNOTES:1. ALL DOORS THROUGH WALL TO BE20 MIN. FIRE RATED OPENINGS.2. MUD AND TAPE ALL GYPSUMBOARD SEAMS IN GARAGE.
UDC / COMM 21.08(A)
INT.
GARAGE
58"
BATT INSULATION (R-19 MIN.)
1
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
A1.0NEW FLOOR PLANS
1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH
13'-0"
13'-112"
7'-11"CEILING
6'-9"CEILING
6'-10.5"CEILING6'-6"CEILING
7'-4.5"CEILING5'-6.5"CEILING
6'-1012"
6'-4.5"CEILING
7'-4.5"CEILING
8'-0"CEILING
2A2.0
A2.11A2.12
A2.01
A3.01
A3.01
6'-0"4'-0"
EQ2'-0"17'-9"2'-0"
13'-0"
23'-4"
ROOM CANTILEVEREDOVER GARAGE WALLBELOW (DASHED)10"
EQ
EQ17'-9"EQ 2'-0"2'-0"
4'-0"CEILING
3'-412"5'-6"
15'-712"3'-0"
3'-612"
6'-0"6'-7"
DNHALL200 BEDROOM201
BATH202
BEDROOM203
NEW PRIMARY SUITEFOYER204 WASHERDRYERLINEN / STORAGE
7'-1014"
9'-212"
EQEQ
200A200B
205 203NEW CLOSET205NEW PRIMARY SUITEBEDROOM206
NEW PRIMARY SUITEBATH207
CCC
CC EQEQ
STORAGE207
4'-1"
2
2
A2
A1 A1
A
A1A
CCC
4'-1"CEILING
5'-6.5"CEILING
5'-6"CEILING
4'-1"CEILING5'-6"CEILING
4'-0"CEILING
7'-11"CEILING
7'-614"OPENING TO ROOMCENTERED ON ROOF RIDGE5'-114" 7'-0"CEILING
LINEN5'-0"1'-6"2'-8"
A.THESE GENERAL NOTES APPLY TO THE CONSTRUCTIONDOCUMENTS AND SHALL GOVERN UNLESS NOTED OTHERWISE BYGENERAL NOTES OR KEYNOTES ON SPECIFIC SHEETS.B.NOTIFY DESIGNER PROMPTLY IF INFORMATION SHOWN IN ONECONSTRUCTION DOCUMENT CONFLICTS WITH INFORMATIONSHOWN ON ANOTHER.C.NOTIFY DESIGNER PROMPTLY IF CONSTRUCTION DOCUMENTSARE INCONSISTENT WITH THE CURRENT APPLICABLE CODES ANDREGULATIONS.D.COORDINATE EXACT LOCATIONS OF LIGHT FIXTURES. SPEAKERS,SMOKE DETECTORS, ACCESS PANELS, HVAC DUCTS, DIFFUSERS,REGISTERS, FIRE ALARMS, AND OTHER SUCH CEILING ITEMS WITHMECHANICAL, ELECTRICAL AND OTHER TRADES. NOTIFYARCHITECT PROMPTLY IF ANY LOCATIONS CONFLICT WITHARCHITECTURAL REFLECTED CEILING PLANS.E.HVAC: COORDINATE POSITION OF GRILLES, DUCTS AND / ORCASSETTES WITH DESIGNER FOR PLACEMENT IN RELATION TOLIGHTING, WALL CLADDING, FURNITURE ARRANGEMENTS,CABINETRY, ETC.F.TYPICAL FLOOR PLAN DIMENSIONS ARE SHOWN TO THE FINISHFACE OF WALLS, CABINETRY AND TRIM UNLESS NOTEDOTHERWISE. WHERE A CLEAR DIMENSION OR OPENING ISREQUIRED OR NOTED, MEASURE DIMENSION TO FACE OFPARTITION FINISH.G.REFER TO PLANS, SECTIONS AND ELEVATIONS FOR PLACEMENTAND ALIGNMENTS WITH EXISTING AND NEW DESIGN ELEMENTS.H.PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREASTHAT ARE SCHEDULED TO RECEIVE CERAMIC TILE FINISH AND ATAREAS REQUIRED BY CODE TO RECEIVE IT.I.PROVIDE TILE BACKER BOARD AT WET AREAS THAT ARESCHEDULED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMICTILE FINISH.J.INSTALL BLOCKING OR BACKER MATERIAL FORATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENTDESCRIBED IN THE DOCUMENTS.K.PROVIDE ACOUSTIC INSULATION BETWEEN ALL BEDROOMS,BATHROOMS, LAUNDRY, MECHANICAL ROOMS AND BETWEENFLOOR / LEVELS OF THE HOME. ALL ELEMENTS OF ACOUSTICRATED PARTITIONS SHALL EXTEND TO ROOF OR FLOOR DECKABOVE AND ALL JOINTS AND PENETRATIONS OF ACOUSTIC RATEDPARTITIONS SHALL BE FILLED AND SEALED.L.ALL ROOF & WALL PENETRATIONS & VENTS, SUCH AS STACK VENTPIPES, DRYER VENT TO MATCH THE FINISH COLOR OF ADJACENTSURFACE. VERIFY COLOR WITH ARCHITECT. WHERE POSSIBLECOORDINATE NEW ROOF PENETRATIONS TO EXIT THROUGH NEWCHIMNEY.M.PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THEPARTITIONS TO OTHER PORTIONS OF THE WORK SHALL BE INACCORDANCE WITH MANUFACTURERS' RECOMMENDED DETAILSAND IN COMPLIANCE WITH APPLICABLE TESTING AGENCYREQUIREMENTS.
PROJECT GENERAL NOTES
DRAWING KEY
NEW WALLEXISTING WALL
EXISTING DOOR
NEW DOOR
C.L. CENTER LINE
000X
A3.-1A5.-1
DOOR TAGWALL ASSEMBLYINTERIORELEVATIONSEE A.5 SHEETSEXTERIORELEVATION &SECTION TAGXWINDOW TAG
TYP TYPICAL
INTERIOR PARTITION NOTESA.ALL INTERIOR PARTITIONS SHALL BE TYPE "A1" UNLESS NOTEDOTHERWISE.B.ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALLEXTEND TO ROOF OR FLOOR DECK ABOVE AND ALL JOINTS ANDPENETRATIONS OF ACOUSTIC RATED PARTITIONS SHALL BEFILLED AND SEALED.C.REFER TO "INTERIOR PARTITION TYPE SUBSCRIPT KEY" FORSYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS ORMODIFICATIONS TO BASIC PARTITION TYPES.D.PARTITION REQUIREMENTS SHOWN ARE CONSIDERED MINIMUMSTANDARDS. WHERE CONDITIONS OF THE WORK CAUSEPARTITION(S) TO EXCEED LIMITS RECOMMENDED BYMANUFACTURER, REINFORCE PARTITION(S.)E.INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASEBOARD SHALL CONFORM TO REQUIREMENTS FOR FIRERATINGS AND ACOUSTICAL RATINGS.F.WHERE PARTITIONS AND/OR FURRING MEET, MAINTAIN A FLUSHSURFACE ON THE SIDE WHERE THE FINISH IS STRAIGHT ORCONTINUOUS UNLESS NOTED OTHERWISE.F.SEE GENERAL PROJECT NOTES FOR ADDITIONAL INFORMATION
SERIES - WOOD STUD PARTITION RATING AS NOTEDAXAXWOODX2" SUBSCRIPT (A)ACOUSTICALINSULATIONSUBSCRIPT (WOOD)MATERIAL FINISHSUBSCRIPT (X" OC)WALL FURRINGDEPTH
X3'-6"SUBSCRIPT (X'-X")PARTITION HEIGHTAS NOTED
INTERIOR PARTITION SUBSCRIPT KEYINTERIOR WALL TYPES
ACOUSTICAL BATT INSULATIONAS DENOTED PER SUBSCRIPT ONLY
1/2" GWB, UNO BYINTERIOR WALL FINISH SCHEDULEWOOD STUDS @ 16" OC, UNOINT.
INT.PARTITIONTYPENOTESPARTITIONWIDTH
6-1/2"A2STANDARD 2x4 WOOD STUDINTERIOR PARTITIONA14-1/2"A3EXISTING EXT / INT WALL WITH INTERIORFURRING (SEE PLAN FOR DETAILS)STANDARD 2x6 WOOD STUDINTERIOR PARTITIONEXISTING WALL+2" - 4"
EXTERIOR WALL TYPES
2x6 DORMER & MUDROOM STUD WALL WITHVENTILATED RAIN SCREEN CLADDING
SIDING PER SCHEDULE
WEATHER BARRIER12" WALL SHEATHING
1/2" GWB, WALL FINISH PER SCHEDULE,2X6 STUDS @ 24": O.C., UNO
14"12"512"58" 714"
INT.
EXT.
2
DENSE PACK CELLULOSE INSULATION ORCLOSED CELL SPRAY FOAM (R19MIN.)VAPOR BARRIER IF CELLULOSE OR SIM.
38"RAIN SCREEN NETTING
45 MIN. WOOD STUD WALL58" GYPSUM WALL BOARD
634"234"234" 58"
2x4 WOOD STUDS AT 16" O.C.
58" TYPE X GYPSUM WALL BOARDNOTES:1. ALL DOORS THROUGH WALL TO BE20 MIN. FIRE RATED OPENINGS.2. MUD AND TAPE ALL GYPSUMBOARD SEAMS IN GARAGE.
UDC / COMM 21.08(A)
INT.
GARAGE
58"
BATT INSULATION (R-19 MIN.)
1
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
A1.1NEW FLOOR PLANS
1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"REMOVE SHUTTERS ON STONE WALL
DEMO GARAGE ROOF
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
DEMO GARAGE ROOF
PREP FOR NEW WINDOWS
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
D2.0EXISTING / DEMOEXTERIOR ELEVATIONS
1EXISTING / DEMO EXTERIOR ELEVATION - EAST1/4" = 1'
2EXISTING / DEMO EXTERIOR ELEVATION - WEST1/4" = 1'
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
7'-514"9'-112" 512" 7'-1134" DEMO GARAGE ROOF
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
D2.1EXISTING / DEMOEXTERIOR ELEVATIONS
1EXISTING / DEMO EXTERIOR ELEVATION - NORTH - NO CHANGE1/4" = 1'2EXISTING / DEMO EXTERIOR ELEVATION - SOUTH1/4" = 1'
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
3'-812"3'-3"
ASPHALT SHINGLE ROOFINGTO MATCH EXISTINGSHED DORMER DETAILS TOMATCH EXISITNG
SHAKE SIDING TO MATCHEXISTING, PAINTED
FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING
GUTTERS, FASICA & SOFFITTO MATCH EXISTING19'-634"
2'-6"4'-6"CCC
RUBBER ROOFING ON LOWSLOPE DORMER ROOF
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
CCC
ASPHALT SHINGLE ROOFINGTO MATCH EXISTINGSHED DORMER DETAILS TOMATCH EXISITNG
SHAKE SIDING TO MATCHEXISTING, PAINTED
FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING
RUBBER ROOFING ON LOWSLOPE DORMER ROOF
DECORATIVE TRIM UNDERCANTILEVERED DORMER,PAINTED
3'-4"4'-6"
3'-4" 6'-0"
A B
FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLOR TOMATCH EXISTING HEIGHT OFADJACENT CORNER WINDOWSFIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING
GUTTERS, FASICA & SOFFITTO MATCH EXISTING
1'-11"VERIFY
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
A2.0NEW EXTERIORELEVATIONS
1EXTERIOR ELEVATION - EAST1/4" = 1'
2EXTERIOR ELEVATION - WEST1/4" = 1'
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
CCSHAKE SIDING TO MATCHEXISTING, PAINTED
FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING
DECORATIVE TRIM UNDERCANTILEVERED DORMER,PAINTEDEXISTING GARAGE DOOR,PAINTED
GUTTERS, FASICA & SOFFIT TOMATCH EXISTING
MATCH NEW PICTURE WINDOWAROUND CORNER TO THESEWINDOW'S EXISTING HEIGHT
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
A2.1NEW EXTERIORELEVATIONS
1EXISTING / DEMO EXTERIOR ELEVATION - NORTH - NO CHANGE1/4" = 1'2EXISTING / DEMO EXTERIOR ELEVATION - SOUTH1/4" = 1'
1'-612" 7'-1134"
BASEMENT
LEVEL 18'-1034"
LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034"
LEVEL 2 - CEILINGEXISTING HOUSE
GARAGE1'-1"1034"
8'-5"TRIM / BRACKETS
GARAGE GABLE ROOFBEHIND DORMERS
7'-814"
7'-2"
6'-8"WINDOW HEADER HEIGHT
BEAM PER STRUCTURAL
PRIMARY SUITE
GARAGE
PRIMARY BATH
GARAGE GABLE ROOFBEHIND DORMERS121.5DORMER SHED DORMER
7'-0"
9'-1134"
6'-8"
STUDIO
© COPYRIGHT 2025, ALL RIGHTS RESERVED
SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET
BLAIR
257 W Suburban Dr. Fox Point, WI 53217
REVISIONS
ADDITION & REMODEL FOR
2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET
EHR
STRUCTURAL ENGINEERGEN 2 ENGINEERING
262.332.9243adam@gen2eng.com
A3.0NEW EXTERIORELEVATIONS
1BUILDING SECTION - GARAGE1/2" = 1'
Source: Village of Fox Point website. First collected Oct 16, 2026.