RecordWell Data

Building Board — Agenda

Village of Fox Point · Milwaukee County · Building Board · meeting of Oct 8, 2025 · Agendas

Open the original document More from Village of Fox Point

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

PLEASE NOTE: Upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through sign langu age interpreters or other auxiliary aids. For additional information or to request these services, contact the Village Clerk at 4 14-351-8900. It is possible that members of, and possibly a quorum of members of, other governmental bodies of the municipality may be in attend ance at the above stated meeting to gather information; no action will be taken by any governmental body at the ab ove stated meeting other than the governmental body specifically referred to above in this notice. NOTICE OF MEETING VILLAGE OF FOX POINT BUILDING BOARD NOTE: THIS MEETING WILL BE HELD Wednesday VIRTUALLY ONLY VIA WEBINAR. NO IN-PERSON ATTENDANCE HELD. October 8, 2025 5:00 P.M. Join Zoom Meeting https://us02web.zoom.us/j/83877661472 Meeting ID: 838 7766 1472 Dial by your location: 312.626.6799 AGENDA 1. Roll call of board members and quorum confirmation. 2. Discussion, corrections, and approval of the minutes of the September 10, 2025 Building Board meeting. 3. Mike Bork, 7457 N Mohawk Rd, proposed windows and siding. 4. Matthew Wuest, 8323 N Santa Monica Blvd, proposed accessory structure. 5. Annie Blair, 257 W Suburban Dr, proposed addition. 6. Adjourn. Posted and Published: October 1, 2025 VILLAGE OF FOX POINT BUILDING BOARD MINUTES A meeting of the Building Board was held via Zoom, on Wednesday, September 10, 2025, at 5:00 pm. Those present included: Justin Racinowski William Feldman Sharon Celek-Absent Lucille Sells Pat Algiers Michael Rakow Notice of the meeting was provided to the North Shore Now and to all others as required by State open meeting laws and posted on the official bulletin boards. MINUTES Motion was made by Pat Algiers to approve the minutes of August 13. Motion was seconded by William Feldman. Motion Caried. AGENDA 1. Pieter Lens, 340 E Daphne Rd, proposed office addition. It was the consensus of the Building Board to approve as submitted. 2. Chad Wenzel, 7539 N Bell Rd, proposed pergola. It was the consensus of the Building Board to approve as submitted. ADJOURN Motion to adjourn Building Board was made by William Feldman. Motion seconded by Pat Algiers. Motion Caried. Building Board adjourned at 5:12 pm. Respectfully Submitted, Michael Rakow Building Inspector Village of Fox Point Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 4'-7" N 06°54'40" E 166.20' WEST 120.00' N 27°03'20" E 187.14' EXISTING GARAGE REMOVE SHED EXISTING CONC. DRIVE EXISTING BRICK WALKWAY EXISTING METAL FENCE RECONFIGURE FENCE AT ACCESSORY BUILDING EXISTING LIMESTONE STEP EXISTING BRICK PATIO EXISTING METAL FENCE 10 FOOT SETBACK 10 FOOT SETBACK 10 FOOT SETBACK EXISTING RESIDENCE EXISTING BRICK WALKWAY LIMESTONE STEPPERS (24x72) PAVER PATIO w/ BRICK EDGING EXISTING LANDSCAPE BLOCK SITE WALL w/ LIMESTONE COPING BUILDING AREA CALCULATIONS C RESIDENCE DISTRICT LOT SIZE 14,506 SF EXISTING RESIDENCE FOOTPRINT 2147 SF PROPOSED ACCESSORY BUILDING FOOTPRINT 740 SF TOTAL EXISTING & PROPOSED BUILDINGS 2887 SF TOTAL OPEN AREA (10,500 SF MIN) 11,619 SF MAX ACCESSORY BUILDING SIZE (15% OF LOT EACH) 2176 SF 6'-2"1'-0" 6" 1'-0" 740 SF PROPOSED ACCESSORY BUILDING SCALE: 1" = 10'1Site Plan C1 Title Page ACCESSORY BUILDING ADDITION 8323 N SANTA MONICA BLVD FOX POINT, WI NORTH Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 1Front / North Elevation 2Front / North Elevation 3West Elevation 4Southwest View 5South Elevation 6Southeast View C2 Existing Photos Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 23'-10" 4"8" 8"4" 31'-0" 4"8" 8"4" 3A3 2A3 1A3 4A3 SCALE: 1/4" = 1'-0"1Foundation Plan NORTH A0 Foundation Plan Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction30'-4" 17'-4" 5'-4" 10" 18'-0" 16'-3" 5'-5" 6" 9'-93/8" 9'-93/8" 9'-93/8" 6" 1'-4" 1'-4" EQ EQ 3'-91/4" EQ EQ 8'-8" 8'-8" 3A3 2A3 1A3 4A3 GOLF BAG & OTTOMAN STOAGE OVERHEAD PROJECTOR TEE LOCATION SCREEN BEV CTR DN 3R TURF FLOORING FLOORING TBD DN 1R REMOVABLE CUSTOM LIGHT / SOUND PROTECTION PANEL AT INSIDE OF WINDOW, TYP. RESIDENTIAL SOUND PANELS ON WALLS & CEILING VIEWING GOLF BLACK OUT SHADES 55"TV GOLF BAG STOAGE w/ COMPUTER ABOVE, CONFIRM HEIGHT & REVISED LOCATION 8-1 /2 FT COUCH 10 FT CEIL ING DRINKS NICHE DRINKS NICHE HOOKS 1/ 2 IN 12 PAVER PATIO INFILL BRICK PATIO EDGING 36x80 EXTERIOR DOOR 30x34 SASH SET FIXED WINDOW 36x60 DOUBLE HUNG WINDOW (2)34x60 DOUBLE HUNG WINDOWS w/ (2)24x1 7 SASH SET FIXED TRANSOMS SCALE: 1/4" = 1'-0"1First Floor Plan A1 First Floor Plan NORTH Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 3A3 2A3 1A3 4A3 21/2" 11/2" 41/2" 11/2" 12 IN 12 12 IN 12 4 IN 12 OUTSIDE OF SHEATHING CONTINUOUS RIDGE VENT FLASHING AT CHANGE OF PLANE GUTTER SCALE: 1/4" = 1'-0"1Roof Plan A2 Roof Plan NORTH Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 26, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 18'-7" 6" 91/2" 1'-0" FIRST FLOOR TOP OF SLAB 10 0 '- 0 " GOLF AREA TOP OF SLAB 98'-8" TOP OF WALL 10 8 '- 8 1/ 2 " TOP OF FOUNDATION 95'-6" ASPHALT SHINGLE ROOF - MATCH EXISTING ON RESIDENCE GUTTER & DOWNSPOUT 5/4x8 TRIM BOARD 8x8 MITER LOCKED COLUMN LAP SIDING - MATCH EXISTING ON RESIDENCE 5/4x6 CORNER BOARDS ALUM CLAD WOOD WINDOW ASSEMBLY w/ SHUTTERS, 5/4x4 CASING, SILL, 5/4x6 APRON, & 5/4x6 HEAD CASING 1- 1/ 2 " T L IMEST ONE CA P BRICK PIER, PATIO EDGING, & PATIO FACING - BRICK TO MATCH EXISTING RESIDENCE POURED CONCRETE FOUNDATIONS & FOOTINGS LIGHT FIXTURE ON 5/4" T LIGHT BLOCK 12 " W IDE FL OW ER BOX w/ 2-1/4"H TRIM ON BRACKETS WINDOW / DOOR HEAD 10 6 '- 8 " FIRST FLOOR TOP OF SLAB 10 0 '- 0 " GOLF AREA TOP OF SLAB 98'-8" TOP OF WALL 10 8 '- 8 1/ 2 " TOP OF FOUNDATION 95'-6" ASPHALT SHINGLE ROOF - MATCH EXISTING ON RESIDENCE GUTTER & DOWNSPOUT 5/4x8 TRIM BOARD LAP SIDING - MATCH EXISTING ON RESIDENCE 5/4x6 CORNER BOARDS BRICK BACE & CAP - BRICK TO MATCH EXISTING RESIDENCE POURED CONCRETE FOUNDATIONS & FOOTINGS FIRST FLOOR TOP OF SLAB 10 0 '- 0 " GOLF AREA TOP OF SLAB 98'-8" TOP OF WALL 10 8 '- 8 1/ 2 " TOP OF FOUNDATION 95'-6" ASPHALT SHINGLE ROOF - MATCH EXISTING ON RESIDENCE GUTTER & DOWNSPOUT 5/4x8 TRIM BOARD LAP SIDING - MATCH EXISTING ON RESIDENCE 5/4x6 CORNER BOARDS POURED CONCRETE FOUNDATIONS & FOOTINGS BRICK BACE & CAP - BRICK TO MATCH EXISTING RESIDENCE 6" FIRST FLOOR TOP OF SLAB 10 0 '- 0 " GOLF AREA TOP OF SLAB 98'-8" TOP OF FOUNDATION 95'-6" ASSUMES 2x1 0 ROOF FRAMING TOP OF WALL 10 8 '- 8 1/ 2 " WINDOW / DOOR HEAD 10 6 '- 8 " ASPHALT SHINGLE ROOF - MATCH EXISTING ON RESIDENCE GUTTER & DOWNSPOUT 5/4x8 TRIM BOARD 8x8 MITER LOCKED COLUMN LAP SIDING - MATCH EXISTING ON RESIDENCE 5/4x6 CORNER BOARDS ALUM CLAD WOOD WINDOW ASSEMBLY w/ SHUTTERS, 5/4x4 CASING, SILL, 5/4x6 APRON, & 5/4x8 HEAD CASING & CROWN 1- 1/ 2 " T L IMEST ONE CA P BRICK PIER, PATIO EDGING, & PATIO FACING - BRICK TO MATCH EXISTING RESIDENCE POURED CONCRETE FOUNDATIONS & FOOTINGS SCALE: 1/4" = 1'-0"1North Elevation SCALE: 1/4" = 1'-0"2East Elevation SCALE: 1/4" = 1'-0"3South Elevation SCALE: 1/4" = 1'-0"4West Elevation A3 Exterior Elevations Drawing Title: Sheet: Wuest Accessory Building Fox Point, WI Project: Caution: Do not scale drawings. These are the property of the designer and may only be used in conjunction with this proect. Sept. 29, 2025Review Set Issue: These drawings and design there in are the exclusive property of CNChambliss Architecture, llc Notice: © Copyright 2025 CNChambliss Architecture llc. All rights reserved. This document, ideas and design incorporated herein are the property of CNChambliss Architecture llc. and are not to be used whole or in part without the written consent of CNChambliss Architecture llc. Not for Construction 3A3 2A3 1A3 4A3 2 A2 2 A2 21/2" 11/2" 41/2" 11/2" 12 IN 12 12 IN 12 4 IN 12 OUTSIDE OF SHEATHING CONTINUOUS RIDGE VENT FLASHING AT CHANGE OF PLANE GUTTER FIRST FLOOR TOP OF SLAB 10 0 '- 0 " GOLF AREA TOP OF SLAB 98'-8" TOP OF FOUNDATION 95'-6" TOP OF WALL 10 8 '- 8 1/ 2 " WINDOW / DOOR HEAD 10 6 '- 8 " BRICK & PAVER PATIO FACING - CONFIRM THICKNESS FOUNDATION DRAINAGE 2" PROTECTION BOARD CONTINUOUS POURED CONCRETE STRIP FOOTING POURED CONCRETE FOUNDATION WALL GRADE BRICK WALL FACING - GROUT SOLID SLOPED CONCRETE SLAB LAP SIDING ON AIR/WATER BARRIER ON 1/ 2 " PL Y W OOD S HE A T HING 2x6 P.T. SILL PLATE ON SILL SEALER w/ ANCHOR BOLTS @ 4'-0" - SEE STRUCTURAL 1/ 2 " GY P. BD. ON V A POR BARRIER WINDOW HEADER - SEE STUCTURAL CONCRETE SLAB OVER VAPOR BARRIER ON 4" INSULATION ON 6" MIN COMPACTED GRAVEL BATT INSULATION WINDOW ASSEMBLY 2x6 TOP PLATE CEILING FRAMING - SEE STRUCTURE 5/8" GYP BD @ CELING BLOWN IN INSULATION R-60 LEDGER BOARD & BLOCKING ASPHALT SHINGLE ROOFING OVER UNDERLAYMENT OVER ICE & WEATHER SHIELD, OVER 3/4" ROOF SHEATHING CONTINUOUS PEAK VENT BEAM - SEE STRUCTURE 1x TRIM - BUILT UP DECO BEA M S4S FINISHED LUMBER PORCH FRAMING S4S FINISHED LUMBER PORCH DECKING GUTTER SCALE: 1/4" = 1'-0"1Roof Plan SCALE: 1/4" = 1'-0"2Building Section A2 Roof Plan & Section NORTH BLAIR RESIDENCE257 W SUBURBAN DR. | FOX POINT, WI 53217 SHEET INDEX: PROJECT SITE PROJECT INFORMATION: STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com T1.0TITLE PAGE ARCHITECTURAL REVIEW BOARDSEPTEMBER 26, 2025 T 1.0 TITLE SHEETT 1.1 EXISTING EXTERIOR IMAGEST 1.2 EXTERIOR ROOF & PAINT COLOR DESIGN DIRECTIOND 1.0 DEMO & NEW FLOOR PLAN - MAIN & SECOND LEVELA 1.1 DEMO & NEW FLOOR PLAN - GARAGED 2.0 DEMO - EXTERIOR ELEVATIONSD 2.1 DEMO - EXTERIOR ELEVATIONSA 2.0 EXTERIOR ELEVATIONSA 2.1 EXTERIOR ELEVATIONSA 3.0 BUILDING SECTION, DETAILSPROJECTSITE BUILDING CODE:ZONING:SF OF RESIDENCE FINISHED (LEVEL 1 & 2 +ADDITION. NOT INCLUDING GARAGE OR UNFINISHEDBASEMENT)SF OF REMODEL WORK EXISTING MAIN: EXISTING SECOND LEVEL: SECOND LEVEL PRIMARY SUITE ADDITION: GARAGE:NO. OF STORIES: WISCONSIN UDCFOX POINT - SINGLEFAMILY2,970 SF (GROSS)1,486 SF1,012 SF 472 SF 484 SF2 EXISTING EXTERIOR - EAST1EXISTING EXTERIOR - SOUTH2EXISTING EXTERIOR - WEST3 EXISTING EXTERIOR - EAST4EXISTING EXTERIOR - WEST5EXISTING EXTERIOR - NORTH6 STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com T1.1EXISTING EXTERIORIMAGES COLOR PALETTE OPTIONS FOR ROOF SHINGLES & SIDING (SHAKE) PAINT COLORS1 STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com T1.2 PROPOSED EXTERIORMATERIAL COLORS 10'-7"10'-7"5'-4"10'-6"10'-11" 12'-112" 8'-0"12'-10"24'-4" 21'-8" 10'-6"1'-0"79'-0"21'-6" 15'-112" 312"2'-112" 7'-712" 5'-0"6'-0"5'-0"12'-0" 10'-6" 14'-512" 21'-612" 5'-5" 6'-0"10'-11"12'-6"37'-0" 12'-0" 11'-1" 2'-6"6'-6" 14'-2"9'-0" 16'-912" 10'-112" 2'-0"414" 21'-9" 10'-9"3'-6"10'-9" 9'-1-1/2"B.O. COLLAR TIE9'-7"T.O. COLLAR TIE7'-5-1/4"B.O. RIDGE BOARD FROM T.O. TIE STAIRS: MAIN LEVEL TO LEVEL 214R @ 7-5/8" H: 56S: 37 21'-114" STAIRS: MAIN LEVEL TO GARAGE2R @ 6-1/2" 2D2.0 D2.11D2.12 D2.01 UP DN REMOVE AND REUSE DOORAT BATHROOM ENTRANCE GC TO VERIFY IF WALL ISSTRUCTURAL DRAWING KEY EXISTING DOOR TO REMAINNEW DOOR, REMOVE EXISTING C.L. CENTER LINED3.-1EXTERIOR ELEVATION &SECTION TAG DEMO DEMO PLAN GENERAL NOTESA.VERIFY ALL EXISTING STRUCTURAL CONDITIONS TO VERIFY WITHSTRUCTURAL DRAWINGS.B.EVALUATE THE CONDITION OF EXTERIOR COMPONENTS, SUCH ASROOF, TIMBERING, WINDOWS, GUTTERS AND MASONRY. SUGGESTREPAIRS, REFINISHING OR REPLACEMENT AS NEEDED.C.SALVAGE ALL EXTERIOR BRICK VENEER IN DEMOLISHED AREASFOR REUSE ON PROJECT.F.PREP FOR NEW FLOORING IN CONSTRUCTION AREA.G.REMOVE EXISTING DOORS IN CONSTRUCTION AREA.H.PRESERVE WOOD FLOORING WHERE POSSIBLE IN CONSTRUCTIONAREA. PREP FOR SANDING & FINISHING. VERIFY WITH ARCHITECT.I.DEMO OR CONSOLIDATE ALL LIGHTING AND ELECTRIC CONDUITON CEILING AND WALLS IN CONSTRUCTION AREA.J.EVALUATE ALL FLOOR DRAINS FOR PROPER DRAINAGE.K.REVIEW AND DEMO EXISTING HVAC DUCTS AS NEEDED INCONSTRUCTION AREA. COORDINATE WITH HVAC CONTRACTOR.EVALUATE EXISTING FURNACE & WATER HEATER FORAPPROPRIATE SIZING. PROVIDE ARCHITECT WITH PROPOSED NEWDUCT LAYOUT TO COORDINATE WITH NEW DESIGN INTENT.L.EVALUATE INSULATION CONDITIONS IN EXISTING EXTERIORWALLS AND ROOF IN CONSTRUCTION AREA. BRING CONDITIONSTO CURRENT ENERGY CODE IF NOT COMPLIANT.M.SALVAGE ALL REMOVED CABINETRY, DOORS AND OTHERINTERIOR ITEMS THAT CAN BE REPURPOSED AT A SECOND HANDBUILDING STORE. VERIFY IF ANY OF THESE ITEMS WILL BEREUSED ON THE PROJECT. EXISTING WALL / NO WORK 12 KEYED NOTESPREP FOR NEW FLOORING, DEMO EXISTINGREMOVE CEILING FINISH. EVALUATECEILING HEIGHT.3VERIFY ALL EXISTING STRUCTURE STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com D1.0EXISTING / DEMOFLOOR PLANS 1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH Missing or invalid reference 11'-112"3'-9"4'-012" 3'-3" 8'-7" 4'-9"2'-4"5'-10"6'-10" 2'-6"30'-9" 7'-712"13'-0"18'-0"7'-11"CEILING 6'-9"CEILING 6'-10.5"CEILING6'-6"CEILING 7'-4.5"CEILING 5'-6.5"CEILING4'-0"CEILING 10'-5" 12'-434" 414" 21'-9" 9'-1-1/2"B.O. COLLAR TIE9'-7"T.O. COLLAR TIE7'-5-1/4"B.O. RIDGE BOARD FROM T.O. TIE 21'-114" 2D2.0 D2.11D2.12 D2.01 DN DRAWING KEY EXISTING DOOR TO REMAINNEW DOOR, REMOVE EXISTING C.L. CENTER LINED3.-1EXTERIOR ELEVATION &SECTION TAG DEMO DEMO PLAN GENERAL NOTESA.VERIFY ALL EXISTING STRUCTURAL CONDITIONS TO VERIFY WITHSTRUCTURAL DRAWINGS.B.EVALUATE THE CONDITION OF EXTERIOR COMPONENTS, SUCH ASROOF, TIMBERING, WINDOWS, GUTTERS AND MASONRY. SUGGESTREPAIRS, REFINISHING OR REPLACEMENT AS NEEDED.C.SALVAGE ALL EXTERIOR BRICK VENEER IN DEMOLISHED AREASFOR REUSE ON PROJECT.F.PREP FOR NEW FLOORING IN CONSTRUCTION AREA.G.REMOVE EXISTING DOORS IN CONSTRUCTION AREA.H.PRESERVE WOOD FLOORING WHERE POSSIBLE IN CONSTRUCTIONAREA. PREP FOR SANDING & FINISHING. VERIFY WITH ARCHITECT.I.DEMO OR CONSOLIDATE ALL LIGHTING AND ELECTRIC CONDUITON CEILING AND WALLS IN CONSTRUCTION AREA.J.EVALUATE ALL FLOOR DRAINS FOR PROPER DRAINAGE.K.REVIEW AND DEMO EXISTING HVAC DUCTS AS NEEDED INCONSTRUCTION AREA. COORDINATE WITH HVAC CONTRACTOR.EVALUATE EXISTING FURNACE & WATER HEATER FORAPPROPRIATE SIZING. PROVIDE ARCHITECT WITH PROPOSED NEWDUCT LAYOUT TO COORDINATE WITH NEW DESIGN INTENT.L.EVALUATE INSULATION CONDITIONS IN EXISTING EXTERIORWALLS AND ROOF IN CONSTRUCTION AREA. BRING CONDITIONSTO CURRENT ENERGY CODE IF NOT COMPLIANT.M.SALVAGE ALL REMOVED CABINETRY, DOORS AND OTHERINTERIOR ITEMS THAT CAN BE REPURPOSED AT A SECOND HANDBUILDING STORE. VERIFY IF ANY OF THESE ITEMS WILL BEREUSED ON THE PROJECT. EXISTING WALL / NO WORK 12 KEYED NOTESPREP FOR NEW FLOORING, DEMO EXISTINGREMOVE CEILING FINISH. EVALUATECEILING HEIGHT.3VERIFY ALL EXISTING STRUCTURE STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com D1.1EXISTING / DEMOFLOOR PLANS 1FLOOR PLAN - SECOND LEVEL1/4" = 1'NPLANNORTH 3'-10" 21'-9" 21'-114" PANTRY PANTRY REF 2A2.0 A2.11A2.12 A2.01 A3.01 A3.01 PANTRY BEDROOM106 FOYER100 15'-612" 4'-212" LIVING101 DINING102KITCHEN / FAMILY103 MUD104 GARAGE105 BATH106 UP DN DN GC TO VERIFY IF WALL ISSTRUCTURAL3'-10"8'-4" 3'-0"3'-4" BANQUETBENCHSEE STRUCTURAL FORGARAGE WALLMODIFICATIONS SEE STRUCTURAL FORGARAGE WALLMODIFICATIONS AB 1 3'-4"4'-0" LINEN106A106B4'-0" 8'-412" 3'-8" A.THESE GENERAL NOTES APPLY TO THE CONSTRUCTIONDOCUMENTS AND SHALL GOVERN UNLESS NOTED OTHERWISE BYGENERAL NOTES OR KEYNOTES ON SPECIFIC SHEETS.B.NOTIFY DESIGNER PROMPTLY IF INFORMATION SHOWN IN ONECONSTRUCTION DOCUMENT CONFLICTS WITH INFORMATIONSHOWN ON ANOTHER.C.NOTIFY DESIGNER PROMPTLY IF CONSTRUCTION DOCUMENTSARE INCONSISTENT WITH THE CURRENT APPLICABLE CODES ANDREGULATIONS.D.COORDINATE EXACT LOCATIONS OF LIGHT FIXTURES. SPEAKERS,SMOKE DETECTORS, ACCESS PANELS, HVAC DUCTS, DIFFUSERS,REGISTERS, FIRE ALARMS, AND OTHER SUCH CEILING ITEMS WITHMECHANICAL, ELECTRICAL AND OTHER TRADES. NOTIFYARCHITECT PROMPTLY IF ANY LOCATIONS CONFLICT WITHARCHITECTURAL REFLECTED CEILING PLANS.E.HVAC: COORDINATE POSITION OF GRILLES, DUCTS AND / ORCASSETTES WITH DESIGNER FOR PLACEMENT IN RELATION TOLIGHTING, WALL CLADDING, FURNITURE ARRANGEMENTS,CABINETRY, ETC.F.TYPICAL FLOOR PLAN DIMENSIONS ARE SHOWN TO THE FINISHFACE OF WALLS, CABINETRY AND TRIM UNLESS NOTEDOTHERWISE. WHERE A CLEAR DIMENSION OR OPENING ISREQUIRED OR NOTED, MEASURE DIMENSION TO FACE OFPARTITION FINISH.G.REFER TO PLANS, SECTIONS AND ELEVATIONS FOR PLACEMENTAND ALIGNMENTS WITH EXISTING AND NEW DESIGN ELEMENTS.H.PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREASTHAT ARE SCHEDULED TO RECEIVE CERAMIC TILE FINISH AND ATAREAS REQUIRED BY CODE TO RECEIVE IT.I.PROVIDE TILE BACKER BOARD AT WET AREAS THAT ARESCHEDULED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMICTILE FINISH.J.INSTALL BLOCKING OR BACKER MATERIAL FORATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENTDESCRIBED IN THE DOCUMENTS.K.PROVIDE ACOUSTIC INSULATION BETWEEN ALL BEDROOMS,BATHROOMS, LAUNDRY, MECHANICAL ROOMS AND BETWEENFLOOR / LEVELS OF THE HOME. ALL ELEMENTS OF ACOUSTICRATED PARTITIONS SHALL EXTEND TO ROOF OR FLOOR DECKABOVE AND ALL JOINTS AND PENETRATIONS OF ACOUSTIC RATEDPARTITIONS SHALL BE FILLED AND SEALED.L.ALL ROOF & WALL PENETRATIONS & VENTS, SUCH AS STACK VENTPIPES, DRYER VENT TO MATCH THE FINISH COLOR OF ADJACENTSURFACE. VERIFY COLOR WITH ARCHITECT. WHERE POSSIBLECOORDINATE NEW ROOF PENETRATIONS TO EXIT THROUGH NEWCHIMNEY.M.PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THEPARTITIONS TO OTHER PORTIONS OF THE WORK SHALL BE INACCORDANCE WITH MANUFACTURERS' RECOMMENDED DETAILSAND IN COMPLIANCE WITH APPLICABLE TESTING AGENCYREQUIREMENTS. PROJECT GENERAL NOTES DRAWING KEY NEW WALLEXISTING WALL EXISTING DOOR NEW DOOR C.L. CENTER LINE 000X A3.-1A5.-1 DOOR TAGWALL ASSEMBLYINTERIORELEVATIONSEE A.5 SHEETSEXTERIORELEVATION &SECTION TAGXWINDOW TAG TYP TYPICAL INTERIOR PARTITION NOTESA.ALL INTERIOR PARTITIONS SHALL BE TYPE "A1" UNLESS NOTEDOTHERWISE.B.ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALLEXTEND TO ROOF OR FLOOR DECK ABOVE AND ALL JOINTS ANDPENETRATIONS OF ACOUSTIC RATED PARTITIONS SHALL BEFILLED AND SEALED.C.REFER TO "INTERIOR PARTITION TYPE SUBSCRIPT KEY" FORSYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS ORMODIFICATIONS TO BASIC PARTITION TYPES.D.PARTITION REQUIREMENTS SHOWN ARE CONSIDERED MINIMUMSTANDARDS. WHERE CONDITIONS OF THE WORK CAUSEPARTITION(S) TO EXCEED LIMITS RECOMMENDED BYMANUFACTURER, REINFORCE PARTITION(S.)E.INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASEBOARD SHALL CONFORM TO REQUIREMENTS FOR FIRERATINGS AND ACOUSTICAL RATINGS.F.WHERE PARTITIONS AND/OR FURRING MEET, MAINTAIN A FLUSHSURFACE ON THE SIDE WHERE THE FINISH IS STRAIGHT ORCONTINUOUS UNLESS NOTED OTHERWISE.F.SEE GENERAL PROJECT NOTES FOR ADDITIONAL INFORMATION SERIES - WOOD STUD PARTITION RATING AS NOTEDAXAXWOODX2" SUBSCRIPT (A)ACOUSTICALINSULATIONSUBSCRIPT (WOOD)MATERIAL FINISHSUBSCRIPT (X" OC)WALL FURRINGDEPTH X3'-6"SUBSCRIPT (X'-X")PARTITION HEIGHTAS NOTED INTERIOR PARTITION SUBSCRIPT KEYINTERIOR WALL TYPES ACOUSTICAL BATT INSULATIONAS DENOTED PER SUBSCRIPT ONLY 1/2" GWB, UNO BYINTERIOR WALL FINISH SCHEDULEWOOD STUDS @ 16" OC, UNOINT. INT.PARTITIONTYPENOTESPARTITIONWIDTH 6-1/2"A2STANDARD 2x4 WOOD STUDINTERIOR PARTITIONA14-1/2"A3EXISTING EXT / INT WALL WITH INTERIORFURRING (SEE PLAN FOR DETAILS)STANDARD 2x6 WOOD STUDINTERIOR PARTITIONEXISTING WALL+2" - 4" EXTERIOR WALL TYPES 2x6 DORMER & MUDROOM STUD WALL WITHVENTILATED RAIN SCREEN CLADDING SIDING PER SCHEDULE WEATHER BARRIER12" WALL SHEATHING 1/2" GWB, WALL FINISH PER SCHEDULE,2X6 STUDS @ 24": O.C., UNO 14"12"512"58" 714" INT. EXT. 2 DENSE PACK CELLULOSE INSULATION ORCLOSED CELL SPRAY FOAM (R19MIN.)VAPOR BARRIER IF CELLULOSE OR SIM. 38"RAIN SCREEN NETTING 45 MIN. WOOD STUD WALL58" GYPSUM WALL BOARD 634"234"234" 58" 2x4 WOOD STUDS AT 16" O.C. 58" TYPE X GYPSUM WALL BOARDNOTES:1. ALL DOORS THROUGH WALL TO BE20 MIN. FIRE RATED OPENINGS.2. MUD AND TAPE ALL GYPSUMBOARD SEAMS IN GARAGE. UDC / COMM 21.08(A) INT. GARAGE 58" BATT INSULATION (R-19 MIN.) 1 STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com A1.0NEW FLOOR PLANS 1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH 13'-0" 13'-112" 7'-11"CEILING 6'-9"CEILING 6'-10.5"CEILING6'-6"CEILING 7'-4.5"CEILING5'-6.5"CEILING 6'-1012" 6'-4.5"CEILING 7'-4.5"CEILING 8'-0"CEILING 2A2.0 A2.11A2.12 A2.01 A3.01 A3.01 6'-0"4'-0" EQ2'-0"17'-9"2'-0" 13'-0" 23'-4" ROOM CANTILEVEREDOVER GARAGE WALLBELOW (DASHED)10" EQ EQ17'-9"EQ 2'-0"2'-0" 4'-0"CEILING 3'-412"5'-6" 15'-712"3'-0" 3'-612" 6'-0"6'-7" DNHALL200 BEDROOM201 BATH202 BEDROOM203 NEW PRIMARY SUITEFOYER204 WASHERDRYERLINEN / STORAGE 7'-1014" 9'-212" EQEQ 200A200B 205 203NEW CLOSET205NEW PRIMARY SUITEBEDROOM206 NEW PRIMARY SUITEBATH207 CCC CC EQEQ STORAGE207 4'-1" 2 2 A2 A1 A1 A A1A CCC 4'-1"CEILING 5'-6.5"CEILING 5'-6"CEILING 4'-1"CEILING5'-6"CEILING 4'-0"CEILING 7'-11"CEILING 7'-614"OPENING TO ROOMCENTERED ON ROOF RIDGE5'-114" 7'-0"CEILING LINEN5'-0"1'-6"2'-8" A.THESE GENERAL NOTES APPLY TO THE CONSTRUCTIONDOCUMENTS AND SHALL GOVERN UNLESS NOTED OTHERWISE BYGENERAL NOTES OR KEYNOTES ON SPECIFIC SHEETS.B.NOTIFY DESIGNER PROMPTLY IF INFORMATION SHOWN IN ONECONSTRUCTION DOCUMENT CONFLICTS WITH INFORMATIONSHOWN ON ANOTHER.C.NOTIFY DESIGNER PROMPTLY IF CONSTRUCTION DOCUMENTSARE INCONSISTENT WITH THE CURRENT APPLICABLE CODES ANDREGULATIONS.D.COORDINATE EXACT LOCATIONS OF LIGHT FIXTURES. SPEAKERS,SMOKE DETECTORS, ACCESS PANELS, HVAC DUCTS, DIFFUSERS,REGISTERS, FIRE ALARMS, AND OTHER SUCH CEILING ITEMS WITHMECHANICAL, ELECTRICAL AND OTHER TRADES. NOTIFYARCHITECT PROMPTLY IF ANY LOCATIONS CONFLICT WITHARCHITECTURAL REFLECTED CEILING PLANS.E.HVAC: COORDINATE POSITION OF GRILLES, DUCTS AND / ORCASSETTES WITH DESIGNER FOR PLACEMENT IN RELATION TOLIGHTING, WALL CLADDING, FURNITURE ARRANGEMENTS,CABINETRY, ETC.F.TYPICAL FLOOR PLAN DIMENSIONS ARE SHOWN TO THE FINISHFACE OF WALLS, CABINETRY AND TRIM UNLESS NOTEDOTHERWISE. WHERE A CLEAR DIMENSION OR OPENING ISREQUIRED OR NOTED, MEASURE DIMENSION TO FACE OFPARTITION FINISH.G.REFER TO PLANS, SECTIONS AND ELEVATIONS FOR PLACEMENTAND ALIGNMENTS WITH EXISTING AND NEW DESIGN ELEMENTS.H.PROVIDE WATER RESISTANT TYPE GYPSUM BOARD AT AREASTHAT ARE SCHEDULED TO RECEIVE CERAMIC TILE FINISH AND ATAREAS REQUIRED BY CODE TO RECEIVE IT.I.PROVIDE TILE BACKER BOARD AT WET AREAS THAT ARESCHEDULED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMICTILE FINISH.J.INSTALL BLOCKING OR BACKER MATERIAL FORATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENTDESCRIBED IN THE DOCUMENTS.K.PROVIDE ACOUSTIC INSULATION BETWEEN ALL BEDROOMS,BATHROOMS, LAUNDRY, MECHANICAL ROOMS AND BETWEENFLOOR / LEVELS OF THE HOME. ALL ELEMENTS OF ACOUSTICRATED PARTITIONS SHALL EXTEND TO ROOF OR FLOOR DECKABOVE AND ALL JOINTS AND PENETRATIONS OF ACOUSTIC RATEDPARTITIONS SHALL BE FILLED AND SEALED.L.ALL ROOF & WALL PENETRATIONS & VENTS, SUCH AS STACK VENTPIPES, DRYER VENT TO MATCH THE FINISH COLOR OF ADJACENTSURFACE. VERIFY COLOR WITH ARCHITECT. WHERE POSSIBLECOORDINATE NEW ROOF PENETRATIONS TO EXIT THROUGH NEWCHIMNEY.M.PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THEPARTITIONS TO OTHER PORTIONS OF THE WORK SHALL BE INACCORDANCE WITH MANUFACTURERS' RECOMMENDED DETAILSAND IN COMPLIANCE WITH APPLICABLE TESTING AGENCYREQUIREMENTS. PROJECT GENERAL NOTES DRAWING KEY NEW WALLEXISTING WALL EXISTING DOOR NEW DOOR C.L. CENTER LINE 000X A3.-1A5.-1 DOOR TAGWALL ASSEMBLYINTERIORELEVATIONSEE A.5 SHEETSEXTERIORELEVATION &SECTION TAGXWINDOW TAG TYP TYPICAL INTERIOR PARTITION NOTESA.ALL INTERIOR PARTITIONS SHALL BE TYPE "A1" UNLESS NOTEDOTHERWISE.B.ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALLEXTEND TO ROOF OR FLOOR DECK ABOVE AND ALL JOINTS ANDPENETRATIONS OF ACOUSTIC RATED PARTITIONS SHALL BEFILLED AND SEALED.C.REFER TO "INTERIOR PARTITION TYPE SUBSCRIPT KEY" FORSYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS ORMODIFICATIONS TO BASIC PARTITION TYPES.D.PARTITION REQUIREMENTS SHOWN ARE CONSIDERED MINIMUMSTANDARDS. WHERE CONDITIONS OF THE WORK CAUSEPARTITION(S) TO EXCEED LIMITS RECOMMENDED BYMANUFACTURER, REINFORCE PARTITION(S.)E.INSTALLATION OF GYPSUM BOARD, BACKER BOARD AND BASEBOARD SHALL CONFORM TO REQUIREMENTS FOR FIRERATINGS AND ACOUSTICAL RATINGS.F.WHERE PARTITIONS AND/OR FURRING MEET, MAINTAIN A FLUSHSURFACE ON THE SIDE WHERE THE FINISH IS STRAIGHT ORCONTINUOUS UNLESS NOTED OTHERWISE.F.SEE GENERAL PROJECT NOTES FOR ADDITIONAL INFORMATION SERIES - WOOD STUD PARTITION RATING AS NOTEDAXAXWOODX2" SUBSCRIPT (A)ACOUSTICALINSULATIONSUBSCRIPT (WOOD)MATERIAL FINISHSUBSCRIPT (X" OC)WALL FURRINGDEPTH X3'-6"SUBSCRIPT (X'-X")PARTITION HEIGHTAS NOTED INTERIOR PARTITION SUBSCRIPT KEYINTERIOR WALL TYPES ACOUSTICAL BATT INSULATIONAS DENOTED PER SUBSCRIPT ONLY 1/2" GWB, UNO BYINTERIOR WALL FINISH SCHEDULEWOOD STUDS @ 16" OC, UNOINT. INT.PARTITIONTYPENOTESPARTITIONWIDTH 6-1/2"A2STANDARD 2x4 WOOD STUDINTERIOR PARTITIONA14-1/2"A3EXISTING EXT / INT WALL WITH INTERIORFURRING (SEE PLAN FOR DETAILS)STANDARD 2x6 WOOD STUDINTERIOR PARTITIONEXISTING WALL+2" - 4" EXTERIOR WALL TYPES 2x6 DORMER & MUDROOM STUD WALL WITHVENTILATED RAIN SCREEN CLADDING SIDING PER SCHEDULE WEATHER BARRIER12" WALL SHEATHING 1/2" GWB, WALL FINISH PER SCHEDULE,2X6 STUDS @ 24": O.C., UNO 14"12"512"58" 714" INT. EXT. 2 DENSE PACK CELLULOSE INSULATION ORCLOSED CELL SPRAY FOAM (R19MIN.)VAPOR BARRIER IF CELLULOSE OR SIM. 38"RAIN SCREEN NETTING 45 MIN. WOOD STUD WALL58" GYPSUM WALL BOARD 634"234"234" 58" 2x4 WOOD STUDS AT 16" O.C. 58" TYPE X GYPSUM WALL BOARDNOTES:1. ALL DOORS THROUGH WALL TO BE20 MIN. FIRE RATED OPENINGS.2. MUD AND TAPE ALL GYPSUMBOARD SEAMS IN GARAGE. UDC / COMM 21.08(A) INT. GARAGE 58" BATT INSULATION (R-19 MIN.) 1 STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com A1.1NEW FLOOR PLANS 1FLOOR PLAN - MAIN LEVEL1/4" = 1'NPLANNORTH BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034"REMOVE SHUTTERS ON STONE WALL DEMO GARAGE ROOF BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" DEMO GARAGE ROOF PREP FOR NEW WINDOWS STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com D2.0EXISTING / DEMOEXTERIOR ELEVATIONS 1EXISTING / DEMO EXTERIOR ELEVATION - EAST1/4" = 1' 2EXISTING / DEMO EXTERIOR ELEVATION - WEST1/4" = 1' BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" 7'-514"9'-112" 512" 7'-1134" DEMO GARAGE ROOF STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com D2.1EXISTING / DEMOEXTERIOR ELEVATIONS 1EXISTING / DEMO EXTERIOR ELEVATION - NORTH - NO CHANGE1/4" = 1'2EXISTING / DEMO EXTERIOR ELEVATION - SOUTH1/4" = 1' BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" 3'-812"3'-3" ASPHALT SHINGLE ROOFINGTO MATCH EXISTINGSHED DORMER DETAILS TOMATCH EXISITNG SHAKE SIDING TO MATCHEXISTING, PAINTED FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING GUTTERS, FASICA & SOFFITTO MATCH EXISTING19'-634" 2'-6"4'-6"CCC RUBBER ROOFING ON LOWSLOPE DORMER ROOF BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" CCC ASPHALT SHINGLE ROOFINGTO MATCH EXISTINGSHED DORMER DETAILS TOMATCH EXISITNG SHAKE SIDING TO MATCHEXISTING, PAINTED FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING RUBBER ROOFING ON LOWSLOPE DORMER ROOF DECORATIVE TRIM UNDERCANTILEVERED DORMER,PAINTED 3'-4"4'-6" 3'-4" 6'-0" A B FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLOR TOMATCH EXISTING HEIGHT OFADJACENT CORNER WINDOWSFIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING GUTTERS, FASICA & SOFFITTO MATCH EXISTING 1'-11"VERIFY STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com A2.0NEW EXTERIORELEVATIONS 1EXTERIOR ELEVATION - EAST1/4" = 1' 2EXTERIOR ELEVATION - WEST1/4" = 1' BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" CCSHAKE SIDING TO MATCHEXISTING, PAINTED FIBERGLASS CLAD WOODWINDOWS. EXTERIOR COLORTO MATCH EXISTING DECORATIVE TRIM UNDERCANTILEVERED DORMER,PAINTEDEXISTING GARAGE DOOR,PAINTED GUTTERS, FASICA & SOFFIT TOMATCH EXISTING MATCH NEW PICTURE WINDOWAROUND CORNER TO THESEWINDOW'S EXISTING HEIGHT STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com A2.1NEW EXTERIORELEVATIONS 1EXISTING / DEMO EXTERIOR ELEVATION - NORTH - NO CHANGE1/4" = 1'2EXISTING / DEMO EXTERIOR ELEVATION - SOUTH1/4" = 1' 1'-612" 7'-1134" BASEMENT LEVEL 18'-1034" LEVEL 2LEVEL 1 - CEILING8'-0"7'-1" 7'-11"1034" LEVEL 2 - CEILINGEXISTING HOUSE GARAGE1'-1"1034" 8'-5"TRIM / BRACKETS GARAGE GABLE ROOFBEHIND DORMERS 7'-814" 7'-2" 6'-8"WINDOW HEADER HEIGHT BEAM PER STRUCTURAL PRIMARY SUITE GARAGE PRIMARY BATH GARAGE GABLE ROOFBEHIND DORMERS121.5DORMER SHED DORMER 7'-0" 9'-1134" 6'-8" STUDIO © COPYRIGHT 2025, ALL RIGHTS RESERVED SEPTEMBER 26, 2025BUILDING BOARDREVIEW SET BLAIR 257 W Suburban Dr. Fox Point, WI 53217 REVISIONS ADDITION & REMODEL FOR 2018 S 1st Street #311 Milwaukee, WI 53207 414.405.3520 josh@studio-ehr.comARCHITECTURAL REVIEW BOARD SET EHR STRUCTURAL ENGINEERGEN 2 ENGINEERING 262.332.9243adam@gen2eng.com A3.0NEW EXTERIORELEVATIONS 1BUILDING SECTION - GARAGE1/2" = 1'

Source: Village of Fox Point website. First collected Oct 16, 2026.