RecordWell Data

Architectural Commission Agenda Packet

City of Oconomowoc · Waukesha County · meeting of Feb 4, 2026 · Agenda packets

Open the original document More from City of Oconomowoc

Text

Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.

City of Oconomowoc ARCHITECTURAL COMMISSION MEETING Wednesday, February 4th 2026 @ 4:30 PM @ City Hall, Conference Room #3 NOTICE: If a person with a disability requires the meeting be accessible or materials at the meeting be in an accessible format, call the City Clerk, at least 48 hours prior to the meeting at 262 -569-2186, or TDD at 262- 569- 3272 to request adequate accommodation. AGENDA: 1. Roll Call and Confirmation of appropriate meeting notification 2. Approve Minutes of January 7th 2026. 3. D & H Industries – Consider/approve a façade update at 510 Worthington Street. 4. 1233-1245 Corporate Center Drive – Consider/approve a master sign plan for 1233-1245 Corporate Center Drive. 5. Reports and comments from the City Planning Department. 6. Reports and comments from the Architectural Commissioners. 7. Adjourn. Members of other C ity governmental bodies (boards, commission, committees, council, etc.) may attend the above noticed meeting of the Architectural Commission in order to gather information. The only action to be taken at the above noticed meeting will be action by the Arch itectural Commission. Architectural Commissioners should notify the City Clerk's Office at 262- 569- 3236 if they are unable to attend. S:Clerk/Committees-Commissions/Architectural/Minutes/2025/ACmin 1-7-26 City of Oconomowoc Architectural Commission Meeting Minutes January 7, 2026 Chairman Flint called the meeting to order at 4:30 pm. Members Present: Flint, Krogstad and Schultz Members Absent: Johnson and Otten Staff Present: Weber, Gallo and Dehnert 2. Approve minutes of December 3, 2025: Motion by Krogstad to approve the December 3, 2025 minutes; second by Schultz. Motion carried 3-0. 3. D & H Industries – Consider/approve a façade update at 510 Worthington Street: Weber explained the applicant intends on installing a new façade over the current exterior of their administrative office and storage building. She would like to see more landscaping around the façade and recommended approval subject to considerations listed in the background. Steve Prell, owner, explained the north wall of the storage building is failing, and they wanted to update that building and the administrative office at the same time. Erik Madisen, architect, provided samples of the ribbed glazed panels to be used on the storage building which will be in light and dark gray colors along with the existing brick base. Prell said the administrative building will have stainless steel between the windows and on the other wider areas he presented a sample of a product that they manufacture which will be a shiny dark blue color. Gallo questioned the type and height of landscaping. Members thought the shiny dark product was a lot for the front of the building; asked what they plan to do for the awning; and suggested using something other than arborvitae because of deer. Prell said they can update the awning if the members want them to; the product will stop at the corner or terminate at the concrete block; the roof units will go away; and they can lighten up the color of the product. Members questioned how the product will handle finger prints being located by the main entrance; they want more detail on how the product will be installed; were concerned with the product having sharp corners; looked at their website and saw vertical panels of the same product; and suggested placing the shiny dark product between the windows and the stainless steel in other larger areas and glass or a flat material around the door at the front entry and maybe this product. Prell said they will bring samples of the matte stainless steel, vertical panels in the correct color with a more matte finish and provide a proper rendering which reflects the correct colors and materials. Motion by Flint to postpone action on the façade update at D & H Industries and come back with the following: 1) a modified design illustrating the proper color and details of the panels; 2) physical samples of the color, finish and size of all proposed materials; and 3) a landscape plan identifying the location, type and size of plantings to be considered; second by Schultz. Motion carried 3-0. 4. Reports and comments from the City Planning Department: Gallo explained a development has been proposed by Cobalt Development which will consist of commercial and residential units in the Pabst Farms. The development will require design guidelines which will come to the Architectural Commission for review. Gallo also mentioned that Council discussed housing ratios last night which will have an impact on this development. 5. Reports and comments from the Architectural Commissioners: Flint said a person had reached out to him who is interested in applying for the open seat when Schultz retires from the Architectural Commission. 6. Adjourn: Motion by Flint to adjourn at 5:36 pm; second by Schultz. Motion carried 3-0. Chris Dehnert, Deputy City Clerk Architectural Commission Background February 4th 2026 : 4:30 pm at City Hall in Conference Room #3 Department of City Planning Kristi Weber | 262.569.2173 oconomowoc-wi.gov/planning Item #3 – D & H Industries; Façade Update The Applicant is requesting approval of a façade update located at 510 Worthington Street. Background The project was previously reviewed and postponed at the January 7th 2026 Architectural Commission meeting. The Applicant has decided to return and move forward with only the storage building update along S. Worthington Street and W. 5 th Street and plans to return at a later time with the administrative building update. A visual is provided below. The facades under review are highlighted in red. Building Materials The application shows a new metal paneling system on the storage east and north elevation. The façade has been designed to enhance the interior racking system as well as to bring light into the space through the positioning of new windows. Planning Staff supports the proposed exterior façade update. The Applicant to provide building material samples to the meeting for review and approval by the Commissioners. Landscaping During the previous review, the Commissioner’s noted that the proposed arborvitae would be heavily enjoyed by the neighborhood deer population. The updated application shows the landscaping updated to pine trees along the northeast elevation of the storage area. Planning Staff supports the updated landscaping proposal s ince it is adjacent to residential dwellings and this is W. 5th St. / North Elevation – Storage S. Worthington St. / Northeast Elevation – Storage Architectural Commission Meeting Background February 4th 2026 – Page 2 a significant change to its appearance, Commissioners to determine if the landscaping as shown is adequate or if it should be increased or decreased along the elevation. The size of the plantings are not noted on the plans. It is recommended the minimum planning size to be 5’-0” in height at the time of planting. Recommendation: Approve the façade update for 510 Worthington Street, with the following considerations: • Building Materials: The Applicant to provide building material samples to the meeting for review and approval by the Commissioners. • Landscaping: Commissioners to determine if the updated landscaping as shown is adequate or if it should be increased or decreased along the elevation. Size of landscaping at the time of planting to be reviewed and approved by the City. Item #4 – 1233-1245 Corporate Center Drive; Master Sign Plan The Applicant is requesting approval of a Master Sign Plan located at 1233-1245 Corporate Center Drive. Background The property has been operating under a legal non- conforming signage regulation. The tenant Baird approached the City with a new sign package early 2025. The signs requested exceeded City Code and this is not considered a face replacem ent. Planning Staff has been working with their corporate office and several sign companies to bring this property into conformance with Section §17.609(3)(a) of the City’s Municipal Code, which requires a Master Sign Plan for all multi -tenant buildings. Tenant Signs #2 The MSP text #2 notes white or ivory plex/acrylic faces. Planning Staff notes if both of these colors are on a building, the ivory will look darker and dirtier than white. For a clean and consistent appearance, Staff suggests requiring all contain white plex/acrylic faces. Wall Signs There are several smaller scaled wall signs adjacent to some of the tenant’s door along the south elevation. Once the Master Sign Plan is approved as submitted, these signs will no longer be allowed. Only individual channel letters either raceway-mounted or flush mounted. Architectural Commission Meeting Background February 4th 2026 – Page 3 Based on the location and size allotment on the building, Planning Staff suggests adding an option for flat wall signs at these identified locations. The Applicant to provide specifications for sizing and sign material at the meeting. Sign Permits Required: If the Master Sign Plan is approved by the Architectural Commission, the tenants can apply online for a sign application with a required permit fee of $50 for each sign. Recommendation: Approve the Master Sign Plan for 1233-1245 Corporate Center Drive , with the following considerations: • Tenant Signs: In the MSP text #2, Staff suggests only white plex/acrylic faces • Wall Signs: The Applicant to provide specifications for sizing and sign material for the signs adjacent to the doorways at the meeting. These wall signs to be added into the allowed sign in the Master Sign Plan. 133 W. PITTSBURGH AVE, SUITE 102|MILWAUKEE, WI 53204|414.277.8000|MADISENMAHER.COM 1 - 2 January 18, 2026 Kristi Weber Planner/ Community Development Specialist City of Oconomowoc 174 E. Wisconsin Ave. Oconomowoc, WI 53066 Re: Project Description/narrative for: D & H Industries façade remodeling 510 S. Worthington St. Oconomowoc, WI 53066 Kristi: Below is the project description/narrative for the proposed façade remodeling at D & H Industries located at 510 S. Worthington St. in Oconomowoc. Current conditions:  The part of the warehouse that will receive new wall panels was built in1951.  The base of the current building consists of a 4’-0” high red face brick base with Kal-wall insulated panels set vertically above to a height of 16’.  The face brick portion of the wall is deteriorated with areas of stair-step cracks and significant spalling. Proposed remodeling work (Shown on drawing A4.01):  Working with the structural engineer, a system was developed to design support for and install 2 ½” insulated metal panels.  The exterior of the metal panels is faced with 22 ga. pre-finished metal.  The insulation value for the metal panels is R-20.  A series of high-mounted aluminum framed windows with clear low-e insulated glazing will be installed to provide natural daylight.  The horizontal base course of the metal panels will a 4’-0” wide section with horizontal flutes in a darker tone.  Horizontal metal panels above the base course will be 2’-6” wide with a smooth finish in a light gray tone. Color samples will be be provided. Future work:  The north wall of the office area (to the west of the warehouse) will be faced with decorative metal panels manufactured by D & H Industries for Millenia Forms. Each panel is approximately 8 ½” x 14” and will be attached to the north face of the office area in a running bond pattern set between the existing window openings. Various colors in the blue and grey range will be installed.  The metal panels will be submitted at a future Architectural Review Board meeting. 133 W. PITTSBURGH AVE, SUITE 102|MILWAUKEE, WI 53204|414.277.8000|MADISENMAHER.COM 2 - 2 Plan of Operation Description:  Hours of operation: Monday to Friday 6am till 6:00pm  The current number of employees will not change as a result of this project.  Current parking locations and counts will not be affected by this project. Exterior lighting:  D & H industries does not have pole mounted light fixtures. Area lighting is achieved through wall mounted light fixtures at the building.  We are proposing wall-pak LED fixtures located over the existing exterior man doors at the warehouse area.  The housing of the wall-pak fixtures will be black. A data sheet of this fixture is attached. Proposed project schedule:  The façade remodeling work is scheduled to take place during 2026. This project reinforces D & H Industries commitment to the City of Oconomowoc. Please let me know if you have any questions or need additional information. Respectfully Submitted, Erik L. Madisen, Principal Madisen|Maher Architects WPLED26N USA Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 1 of 2 LED 26W Wall packs. patent-pending thermal management system. 100,000 hour L70 lifespan. 5-year, no-compromise warranty. Color: Bronze Weight: 7.2 lbs Project: Type: Prepared By: Date: Driver Info Type Constant Current 120V 0.22A 208V 0.13A 240V 0.11A 277V 0.10A Input Watts 28.9W LED Info Watts 26W Color Temp 4000K (Neutral) Color Accuracy 70 CRI L70 Lifespan 100,000 Hours Lumens 3,738 lm Efficacy 129.3 lm/W Technical Specifications Compliance UL Listed: Suitable for wet locations. Suitable for mounting within 4 ft (1.2m) of the ground. IP Rating: Ingress protection rating of IP66 for dust and water DLC Listed: This product is on the Design Lights Consortium (DLC) Qualified Products List and is eligible for rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements. DLC Product Code: P0000175P Performance Lifespan: 100,000-Hour LED lifespan based on IES LM-80 results and TM-21 calculations Wattage Equivalency: Equivalent to 150W Metal Halide Electrical Driver: Constant Current, Class 2, 120-277V, 50/60Hz, 120V: 0.22A, 208V: 0.13A, 240V: 0.11A, 277V 0.10A Dimming Driver: Driver includes dimming control wiring for 0-10V dimming systems. Requires separate 0-10V DC dimming circuit. Dims down to 10%. THD: 10.02% at 120V, 10.55% at 277V Power Factor: 98.3% at 120V, 95.4% at 277V Construction Finish: Formulated for high durability and long-lasting color Ambient Temperature: Suitable for use in up to 40°C (104°F) Cold Weather Starting: The minimum starting temperature is -40°C (-40°F) Green Technology: Mercury and UV free. RoHS-compliant components. LED Characteristics Color Consistency: 3-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color Color Stability: LED color temperature is warrantied to shift no more than 200K in color temperature over a 5-year period Color Uniformity: RAB's range of Correlated Color Temperature follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017. Other Patents: The WPLED design is protected by U.S. Pat. D634878, Canada Pat 134878, China Pat. CN301649064S. 5-Year, No-Compromise Warranty: RAB warrants that our LED products will be free from defects in materials and workmanship for a period of five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish. RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty. FTC Country of Origin: This product was assembled in the USA by RAB using imported components Buy American Act Compliance: This product complies with the Buy American Act WPLED26N USA Need help? Tech help line: (888) 722-1000 Email: techsupport@rablighting.com Website: www.rablighting.com Copyright © 2025 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 2 of 2 Technical Specifications (continued) Optical BUG Rating: B1 U0 G0 Dimensions Features High performance LED light engine Maintains 70% of initial lumens at 100,000-hours Weatherproof high temperature silicone gaskets Superior heat sinking with die cast aluminum housing and external fins 100 up to 277 Volts 5-Year, No-Compromise Warranty HGF EDCB dh&INDUSTRIES AMATCHLINEWAREHOUSE OFFICE 123456PRE-FINISHED METALCOPING.2 1/2" x 30" PRE-FINISHEDSMOOTH FACE INSULATEDMETAL PANELS.2 1/2" x 4'-0" HIGHPRE-FINISHED TEXTUREDINSULATED METAL PANELS.PINE TREE LANDSCAPING. dh&INDUSTRIES AMATCHLINEWAREHOUSE OFFICENOTE: THERE IS NO EXTERIOR WORK AT THEOFFICE AREA. EXTERIOR FINISHES AT THE OFFICEAREA WILL BE SUBMITTED AT A FUTURE TIME. COLOREDELEVATIONSA4.011/8" = 1'-0"NORTH ELEVATION - EAST1 GENERAL NOTESFACADE PENETRATIONS ARE SHOWN BASED ONPHOTOGRAPHS OF THE EXISTING BUILDING. GC SHALLVERIFY WITH OWNER WHICH PENETRATIONS CAN BEABANDOND AND WHICH WILL BE MAINTAINED.CONTACT DIGGERS HOTLINE PRIOR TO EXCAVATIONSFOR NEW FOUNDATION WALLS. 1/8" = 1'-0"EAST ELEVATION3 1/8" = 1'-0"NORTH ELEVATION - WEST2 1.2. 25-014ELMELMPROJECT NUMBERSTART DATEDRAWN BYCHECKED BY DATEISSUED SETDrawings and Specifications as instruments of serviceare the property of Madisen Maher Architects, whetherthe work for which they are made beexecuted or not and are not to be used or copied onother work except by written agreement withMadisen Maher Architects. 05-01-2025 EXTERIOR WALL REMODELINGFOR:D & HINDUSTRIES CLIENT:REVIEW DRAWINGS DEC. 10, 2025 PROJECT START5-1-25 WORTHINGTON PROPERTIES510 S. WORTHINGTON ST.OCONOMOWOC, WI 53066 133 W. PITTSBURGH AVE, SUITE 102MILWAUKEE, WI 53204414.277.8000MADISENMAHER.COMA R C H I T E C T S 510 S. WORTHINGTON ST.OCONOMOWOC, WI 53066 REVIEW SET TO OWNER5-19-25REVISED WALL SECTIONS7-15-25UPDATED DRAWING SET11-7-25ARC. BOARD SUBMITTAL12-10-25ARC. BOARD SUBMITTAL1-18-26 METAL PANEL NOTESINSULATED METAL PANELS SHOWN AT WAREHOUSEAREA ARE BASED ON QUADCORE OPTIMO 2 1/2" THICKINSULATED METAL PANELS AS MANUFACTURED BYKINGSPAN.·ORIENTATION: PANELS SET HORIZONTALLY.·MODULE WIDTH: BASE: 48, UPPER PANELS: 30".·STEEL GAUGES: EXTERIOR: 22 GA, INTERIOR: 24 GA·EMBOSSING: EXTERIOR: SMOOTH. INTERIOR:SMOOTH.·MAXIMUM PANEL LENGTH: 24'.·COLOR SELECTION BY OWNER.·R-VALUE: 8 PER INCH. 2 1/2" PANEL: R-20.·WARRANTY: 2 YEAR STANDARD WORKMANSHIPWARRANTY, 20 YEAR FINISH WARRANTY.DECORATIVE METAL PANELS AT NORTH WALL OF OFFICEARE FURNISHED BY OWNER AND INSTALLED BY GC.COLOR SELECTION BY OWNER. DECORATIVE PANELSWILL BE SUBMITTED AT A FUTURE ARCHITECTURAL REVIEWBOARD MEETING. 1. 2. OCONOMOWOC CORPORATE CENTER Master Sign Plan Property Owner: Oconomowoc Corporate Center 1233-1245 Corporate Center Drive Oconomowoc, WI 53066 The information listed below is to establish a MASTER SIGN PLAN for tenants at Oconomowoc Corporate Center Marketplace, 1233–1245 Corporate Center Drive, Oconomowoc, Wisconsin. After approval, all tenants will utilize this information as a requirement for signage for this property. TENANT SIGNS – All signs will be individual channel letters, either raceway-mounted or remote, flush-mounted: 1. If raceways are used, they are to be painted to match the sign band 2. Letters to have white or ivory plex/acrylic faces with surface-applied vinyl to the faces per the tenant’s logo/specs 3. Illumination using white LED’s powered by transformer(s) as needed. 4. Letters to be constructed of .040 aluminum returns with painted outside to match faces and painted white interiors. 5. Letter styles may match corporate identification (block, script, serif, etc.) 6. Total square footage of signage shall not exceed 1.5 square feet per lineal foot of lease frontage. 7. Corporate logos may be used in conjunction with letters when logos are part of a corporate identity. The maximum logo height shall not exceed 8” above the maximum letter height allowed. 8. Total length of signs not to exceed 80% of tenant lease length. 9. All signs will have steady illumination. No flashing or blinking lights will be permitted. 10. Tenants will be liable and bear all associated costs for the removal and/or changes of signs, sign installation/removal. 11. Replacement faces for existing monument sign to be .125" flat aluminum painted Blue- PMS 287 C Blue. Graphics/logo to be routed out from aluminum face w/ ½” thick clear acrylic with first surface applied white trans. Vinyl overlays and 2 nd surface diffuser film. SIGN APPROVALS – The Landlord must approve all signs prior to fabrication. A sign permit must be obtained from the City of Oconomowoc before construction of any sign can commence. All signs are subject to the criteria in the Master Sign Plan. The more stringent of the requirements will take precedence. Landlord Signature: _____________________________ Infinite possibilities, ideal solutions. SITE ADDRESS: 1245 Corporate Center Dr. Oconomowoc, WI 53066 LOCATION NUMBER: 4 onestratus.com 888.503.1569 View in Google Maps PRINTS ARE THE EXCLUSIVE PROPERTY OF STRATUS. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF STRATUS. ADDRESS: ORDER NUMBER: SITE NUMBER: ELECTRONIC FILE NAME: PROJECT NUMBER: PROJECT MANAGER: PAGE NO.: Rev # Req # Date/Artist DescriptionRev # Req # Date/Artist Description Rev 7 Rev 8 545060 545850 07/30/25 JT 08/05/25 JT 1234557 1245 Corporate Center Dr. Oconomowoc, WI 53066 88584 KELLY HALL4 2 CLIENT: Original Rev 1 Rev 2 Rev 3 Rev 4 Rev 5 Rev 6 517268 519659 532281 535258 536348 539398 539582 02/27/25 JT 03/17/25 BRAZ 05/20/25 DB 06/05/25 JT 06/11/25 JT 06/27/25 KM 06/30/25 KM onestratus.com 8 8 8 . 5 0 3.1 5 6 9 8959 Tyler Boulevard Mentor, Ohio 44060 G:\ACCOUNTS\B\BAIRD\2025\WI\4_Oconomowoc\ 4_Oconomowoc_R8.cdr For Reference - NTS SITE PLAN E05 E01 Updated address, site number and PM name Del. ST E02 & E03 per request PRINTS ARE THE EXCLUSIVE PROPERTY OF STRATUS. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF STRATUS. ADDRESS: ORDER NUMBER: SITE NUMBER: ELECTRONIC FILE NAME: PROJECT NUMBER: PROJECT MANAGER: PAGE NO.: Rev # Req # Date/Artist DescriptionRev # Req # Date/Artist Description Rev 7 Rev 8 545060 545850 07/30/25 JT 08/05/25 JT 1234557 1245 Corporate Center Dr. Oconomowoc, WI 53066 88584 KELLY HALL4 3 CLIENT: Original Rev 1 Rev 2 Rev 3 Rev 4 Rev 5 Rev 6 517268 519659 532281 535258 536348 539398 539582 02/27/25 JT 03/17/25 BRAZ 05/20/25 DB 06/05/25 JT 06/11/25 JT 06/27/25 KM 06/30/25 KM onestratus.com 8 8 8 . 5 0 3.1 5 6 9 8959 Tyler Boulevard Mentor, Ohio 44060 G:\ACCOUNTS\B\BAIRD\2025\WI\4_Oconomowoc\ 4_Oconomowoc_R8.cdr EXISTING CONDITIONS EAST (Street Facing) ELEVATIONE01 EXISTING SIGN SF: PROPOSED SIGN SF:Scale: 3/32"=1'-0" 41.9 Existing ±3'-8"H (6'-0"OAH) x ±6'-8"OAW Logo Cabinet to be removed and replaced with new as shown; Wall patched & painted to like new condition - end to end All paint finishes to be Satin unless otherwise noted WALL COLOR: White COLOR PALETTE Updated dims based on survey info provided Added option Added option A from art, removed option B tag Updated sign 40 Updated sign C|L C|L ±93'-0" Frontage 34'-0" 18'-0" 6'-9" PRINTS ARE THE EXCLUSIVE PROPERTY OF STRATUS. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF STRATUS. ADDRESS: ORDER NUMBER: SITE NUMBER: ELECTRONIC FILE NAME: PROJECT NUMBER: PROJECT MANAGER: PAGE NO.: Rev # Req # Date/Artist DescriptionRev # Req # Date/Artist Description Rev 7 Rev 8 545060 545850 07/30/25 JT 08/05/25 JT 1234557 1245 Corporate Center Dr. Oconomowoc, WI 53066 88584 KELLY HALL4 4 CLIENT: Original Rev 1 Rev 2 Rev 3 Rev 4 Rev 5 Rev 6 517268 519659 532281 535258 536348 539398 539582 02/27/25 JT 03/17/25 BRAZ 05/20/25 DB 06/05/25 JT 06/11/25 JT 06/27/25 KM 06/30/25 KM onestratus.com 8 8 8 . 5 0 3.1 5 6 9 8959 Tyler Boulevard Mentor, Ohio 44060 G:\ACCOUNTS\B\BAIRD\2025\WI\4_Oconomowoc\ 4_Oconomowoc_R8.cdr ADDITIONAL LAYOUTS Blue Letters/White Halo Illum. - Stacked Blue Letters/White Halo Illum. - Extreme Linear Blue Letters/White Halo Illum. - Linear WM VERIFY SMALLEST TAGLINE LETTER SIZE REQUIRED TO ILLUMINATE Added option Added option A from art, removed option B tag Removed redline Updated wign type per request Reverted back to ST from R6 Scale: 1/2"=1'-0" FACE LIT CHANNEL LETTERS - Trimless SIMULATED NIGHT VIEW THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE 600.6(A) (1) OF THE NATIONAL ELECTRIC CODE. TRIMLESS: Blue perf. faces; Blue returns E01 FACES: ILLUM.: INSTALL: Principal Sloan White LED’s as required by manufacturer; Remote Power Supplies WALL MAT.: Thru bolted flush to wall surface using all thread into approved blocking; 12" standard length of min 3/8” threaded rod will be supplied unless otherwise noted; Spacers to be provided for uneven wall surface and painted to match wall RETURNS: BACKS: 3” Deep .040 alum. returns pre-finished white interior; Outsides painted Blue .063 alum. insides painted Reflective White Wood Siding 41.9 square feet FLT36.i.l.bl.f 1/2" 1/2" acrylic face w/ routed back flange to sit flush Aluminum return Channel lock or rivet #6 C/S FH screw DROP IN FACE DETAIL Aluminum back STUD WALL CONCRETE MASONR Y WALL Thru bolt - all thread fasteners w/ wood blocking or angle iron stringer Toggle bolts w/ hollow core- plywood backing Kwik Bolts or Expansion lag bolts & shields w/ solid concrete *MOUNTING METHOD: (Use appropriate method following wall inspection) Siding C/S FH head screw Acrylic face w/ routed edge to drop into returns Spacers Aluminum back 18 ga PLTC Wire Crimp Connector LED modules Weep holes 5/16” dia w/ light baffle if req’d. Exterior locations only 3/8” Riv nut & bolt SS Threaded Rod w/ Hex Nut & Lock Washer Silicone caulk all penetrations Steel Angle or approved blocking Plastic Bushing Wire Nut Junction Box Electrical conduit & fitting Anchor bolt (may vary) w/ mounting angleBolt, Hex head, 1/4”-20 w/ nut & washer #18ga PLTC Wire Power supply box Stud for Grounding Power supply 12 ga Stranded THHN Wire Fitting & Conduit - To Primary 12 ga Stranded THHN Wire Fitting & Conduit - To Primary Disconnect Switch w/ lock Thru bolt - all thread fasteners w/ wood blocking or angle iron stringer Toggle bolts w/ hollow core- plywood backing Kwik Bolts or Expansion lag bolts & shields w/ solid concrete *MOUNTING METHOD: (Use appropriate method following wall inspection) DROP IN, FACE LIT LED | REMOTE, FLUSH | SIDING 1/2" #2406 white acrylic w/ surface applied Blue perf. day/night film; ; Faces to have routed back flange & will dropLetters will illuminate White at night into returns & secure with c/s fasteners; Fasteners painted to match returns 13'- 1-5/8" 3'-0" 3'- 8" All paint finishes to be Satin unless otherwise noted PMS 287 C Blue 3M 3635-210 Perf. day/night film digitally printed to match COLOR PALETTE PMS 287 C Blue SPACERS: White QUANTITY: (1) ONE LETTERSET required for EAST elevation Aluminum returns Blue Day/White Night - Linear PRINTS ARE THE EXCLUSIVE PROPERTY OF STRATUS. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF STRATUS. ADDRESS: ORDER NUMBER: SITE NUMBER: ELECTRONIC FILE NAME: PROJECT NUMBER: PROJECT MANAGER: PAGE NO.: Rev # Req # Date/Artist DescriptionRev # Req # Date/Artist Description Rev 7 Rev 8 545060 545850 07/30/25 JT 08/05/25 JT 1234557 1245 Corporate Center Dr. Oconomowoc, WI 53066 88584 KELLY HALL4 5 CLIENT: Original Rev 1 Rev 2 Rev 3 Rev 4 Rev 5 Rev 6 517268 519659 532281 535258 536348 539398 539582 02/27/25 JT 03/17/25 BRAZ 05/20/25 DB 06/05/25 JT 06/11/25 JT 06/27/25 KM 06/30/25 KM onestratus.com 8 8 8 . 5 0 3.1 5 6 9 8959 Tyler Boulevard Mentor, Ohio 44060 G:\ACCOUNTS\B\BAIRD\2025\WI\4_Oconomowoc\ 4_Oconomowoc_R8.cdr PROPOSED SIGNAGE Scaled Proportionally EXISTING CONDITIONS Side A Side B Side A Side B Scale: 1"=1'-0" REPLACEMENT FACESE05 6.5 square feet RF20.al 3'- 10-1/2" Face Cut Size 1'- 8" Face Cut Size 8-1/2" GRAPHICS: Routed out from aluminum face w/ 1/2" thick clear acrylic with first surface applied White trans. vinyl overlays and 2nd surface diffuser film; NO STUDS - face will slide into existing retainer system (2) TWO REPLACEMENT FACES required for existing D/F Illum. Multi-Tenant MonumentQUANTITY: FACES: .125" flat aluminum painted Blue CABINET: Existing D/F cabinet with to remain2-1/4" retainers and divider bars Existing faces to be removed and replaced with new as shown SIMULATED NIGHT VIEW All paint finishes to be Satin unless otherwise noted COLOR PALETTE White 3M 3630-20 trans. vinyl PMS 287 C Blue 3M 3630-157 Sultan Blue V.O.: 1'-5"H x 3'- 8-3/4" Clear space requirement - 50% height of letter “I” Acrylic backer panel stud mounted to alum. face Studs Attached to Aluminum Face Aluminum face w/ routed out graphics ROUTED FACE; PUSH-THRU GRAPHICS Acrylic push thru letters; Resin bonded to acrylic backer 3M 3635-70 Diffuser film SIDE A & B ARE THE SAME Updated dims based on survey info provided

Source: City of Oconomowoc website. First collected Oct 18, 2026.